Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2016 Sep 4.
Published in final edited form as: J Proteomics Bioinform. 2016 May 24;9(5):151–157. doi: 10.4172/jpb.1000401

Mechanistic Parameterization of the Kinomic Signal in Peptide Arrays

Alex Dussaq 1, Joshua C Anderson 1, Christopher D Willey 1, Jonas S Almeida 2,*
PMCID: PMC5010871  NIHMSID: NIHMS808042  PMID: 27601856

Abstract

Kinases play a role in every cellular process involved in tumorigenesis ranging from proliferation, migration, and protein synthesis to DNA repair. While genetic sequencing has identified most kinases in the human genome, it does not describe the ‘kinome’ at the level of activity of kinases against their substrate targets. An attempt to address that limitation and give researchers a more direct view of cellular kinase activity is found in the PamGene PamChip® system, which records and compares the phosphorylation of 144 tyrosine or serine/threonine peptides as they are phosphorylated by cellular kinases. Accordingly, the kinetics of this time dependent kinomic signal needs to be well understood in order to transduce a parameter set into an accurate and meaningful mathematical model.

Here we report the analysis and mathematical modeling of kinomic time series, which achieves a more accurate description of the accumulation of phosphorylated product than the current model, which assumes first order enzyme-substrate kinetics. Reproducibility of the proposed solution was of particular attention. Specifically, the non-linear parameterization procedure is delivered as a public open source web application where kinomic time series can be accurately decomposed into the model’s two parameter values measuring phosphorylation rate and capacity. The ability to deliver model parameterization entirely as a client side web application is an important result on its own given increasing scientific preoccupation with reproducibility. There is also no need for a potentially transitory and opaque server-side component maintained by the authors, nor of exchanging potentially sensitive data as part of the model parameterization process since the code is transferred to the browser client where it can be inspected and executed.

Keywords: Kinomics, JavaScript, Non-linear regression, Kinomic peptide array, PamGene

Introduction

Kinases have been extensively studied since the discovery of enzyme regulation via phosphorylation in the 1950’s. They represent more than 500 proteins and 100,000 phosphorylation sites [1]. They have been examined, among other things, as regulators, signal transducers, and are the second most drugged gene class [2]. While genetic sequencing has identified most kinases in the human genome, it does not describe the ‘kinome’, at the level of the activity of kinases on kinase targets. Kinases play a very important role in cancer development and kinomics, a global description of kinases and their substrates, shows great promise in the field of personalized medicine, correspondingly, numerous technologies have been developed to measure the kinome activity.

Of the techniques for kinome examination, peptide chips show significant promise due to several key features: 1) They can be used for high-throughput screening, 2) they allow the investigator to directly measure the effects of a drug, 3) they are comparably easy to create, and 4) they maintain similar enzyme kinetics to in vivo [3]. In particular, we are examining the PamGene PamChip© array, which allows a researcher to record and compare the phosphorylation of 144 13 amino acid long peptides containing one or more phosphorylatable residues [4].

Total protein lysates are prepared with protease and phosphatase inhibitors and 1–10 μg of lysate are mixed in kinase buffer with ATP and Mg2+. Samples are then loaded onto the PamStation© along with fluorescently labeled anti-phosphoserine, anti-phosphothreonine, or anti-phosphotyrosine antibodies. Using microfluidics, the sample is repeatedly pumped through an aluminum oxide matrix containing an array of phosphorylatable peptide probes. Active kinases within the lysate sample can phosphorylate these peptide probes that are then quantified by measuring the fluorescence of the phospho-specific antibodies using a charge-coupled device (CCD) camera. Each PamChip® experiment produces two sets of data for 144 phosphorylatable amino acid residues. The first, a non-linear model, uses a camera exposure time of 50 ms to compare the phosphorylation of the residues at time points throughout the experiment (Figure 1). The second, a linear model, uses varying camera exposure time from 5–150 ms to quantify the end level phosphorylation following the washing away of the reactants. For the purposes of this publication we will discuss the first, non-linear, time series model.

Figure 1.

Figure 1

Representation of the data flow for the phosphorylation reaction for PamGene PamChip® experiments. Cycle number represents reaction time. Fluorescence intensity of peptide phosphorylation is recorded using a camera with a 50 ms exposure. All images were adjusted using color correction curve in Gimp (smooth curve x:225>10, y:225>165). (A) Two images taken during the phosphorylation reaction. (B) Two selected spots from (A) displayed for every time point. (C) Graphical representation of the median signal - background value calculated by the PamGene BioNavigator and plotted utilizing Google Charts.

Due to the nature of kinases, any of the 144 peptides will likely have numerous kinases acting upon them [5,6]; additionally the secondary step of antibody binding to produce a fluorescent signal further complicates the picture. This leads to a serious problem with deconvoluting the signal to the representative original kinases. In the literature upstream kinases are predicted using probable upstream kinase prediction linked back to biological pathways. This has shown utility in a wide range of disease models such as schizophrenia [7,8], HIV latency [9], renal cell carcinoma [10], Glioblastoma [11,12] and lung cancer [13]. Additionally a number of studies have utilized ex vivo treatments with kinase inhibitors not only against cells prior to lysis, but also treating lysates directly before profiling. In rectal cancer ex vivo treatment with the kinase inhibitor sunitinib was used to properly group and identify patients that would respond to both chemotherapy and radiotherapy [14] as well as to predict tumor cell dissemination within patients [15]. However, kinetic data, using a derivative of the curve fit at an early point (initial velocity or slope), was used in a similar drug study by Versele et al. [16] to comparatively measure, and predict response in 27 cancer cells to a multitargeted kinase inhibitor, a finding that was validated in xenograft tumor bearing mice. It is of the utmost importance that the signals created properly represent the data and introduce minimal error. Therefore we sought to investigate the error introduced by the time series curve fitting procedure.

The current model of the kinomic time series [17] relies on an exponential model, which is typically associated with processes as diverse as biological growth, radioactive decay, and first order enzyme kinetics, however given the complicated picture we present above we theorize that first order kinetics will not be the optimal method to represent the data.

y=y0+ymax·(1-e-c·x) (1)

As the results described below will confirm, we hypothesize, the biochemical processes underlying the production of the phosphorylated fluorescent signals are better described by hyperbolic, not exponential, activity curves.

It should be noted that previous studies by other authors have approached the analysis of the kinomic signal describing it with penalized smoothing splines [18]. However, like other smoothing approaches to signal description [19,20]; those approaches seek to subtract the statistical structure of signal noise rather than capturing the underlying mechanism. Since our goal is to translate the dynamics of the kinomic signal into a vector of parameters that can be mapped to biochemical mechanisms that line of work was not pursued here. In the same vein, this study does not approach the systems dynamics that multiple kinomic signals may in fact be describing collectively. That systems-level modeling of the kinase signal is approached in studies like “Mathematical Models of Protein Kinase Signal Transduction” [21]. More broadly, the description of multi-signal systems requires the adoption of more generic frameworks, if for no other reason than for the sake of maintaining parametric sensitivity. An excellent review of the generalization of individual reaction kinetics into broader Biochemical Systems Theory frameworks such as S-Systems can be found in Voit EO [22]. The relevant context for the study reported here is that parameterization of kinomic signals produces more a meaningful and accurate description of both individual signal and system-level kinase activity.

Methods

PamGene

PamGene utilizes a peptide array consisting of 144 unique peptides in approximately equal concentrations. Each peptide contains one or more phosphorylatable residues, and all peptides are simultaneously exposed to cell lysate containing active kinases. A detailed description of the sample preparation, processing, and analysis can be found here [11]. Once a residue is phosphorylated fluorescent antibodies bind the phosphorylated peptide residue. The signal recorded is then the amount of phosphorylation based on this fluorescence, for a series of time points [23]. The signal is normalized using PamGene®’s PAMCHIP EVOLVE software as part of the BioNavigator software suite in two major steps: (1) Image analysis segments the image to identify the spots and the local region around them, and then (2) local background pixels are identified as the corners of a square cell around the spots. Median signal over the spot is subtracted from the median background signal to produce a normalized value [24].

Curve fitting

The numerical methods developed for this study sought to satisfy recommendations for reproducibility to the fullest. Accordingly, criteria were set to utilize an open source, version controlled, and web executable application. Those requirements were met by developing a JavaScript library implementing a simplified, portable, steepest-descent non-linear regression algorithm. Source code can be found (https://github.com/adussaq/amd_cf).

To avoid blocking the accompanying web application, this library was written to be run within web workers, using background processes supported by modern Web Browsers [25]. A specialized library that coordinates the web workers in the execution of this algorithm by queuing the asyncronous tasks was developed and is also made publicly available with open source at https://github.com/adussaq/amd_ww/. Both of these modules are designed to work with all modern web browsers including Mozilla’s Firefox, Google Chrome, and Apple’s Safari, both on the mobile and desktop platforms.

The iterative process to minimize the sum of square deviations is summarized below:

X=[X1,Xn],X1=[x1,1,,x1,p],Y=[y1,,yn],Y=f(X,Po)P0=[p0,1,,p0,m],P1=[p1,1,,p1,m],S=[s1,,sm]sse(Y,f(X,P))=q=1n(f(Xq,P)-Yq)2
  1. p1,1 = s1 + P0,0

  2. if sse(Y,f(X,P1))< sse(Y,f(X,P0))

    P0,1 = P1,1, s1 = s1 * 1.2

    else

    P1,1 = P1,0, s1 = s1 * −0.5

  3. Repeat 1 – 2 for p0,2 through p0,m

  4. Repeat 1 – 3 until end condition are satisfied

Where P is the constant parameter vector, X is an independent matrix; Y is the corresponding dependent variable for the equation ŷi=f(X,P). S are the steps taken in each iteration of the algorithm and sse is the sum of square deviations. Several parameters may be set, including a max iteration count (default 1000), initial step (default 1/100 of P0), and minimum percent change of sum of square deviations (default 6e–5%). In addition to the parameter vector, this returns an R2 and a Wald-Wolfowitz (WW) Runs Test to measure goodness of fit. Initial parameters for each equation were determined by iteratively resolving the equation for individual points algebraically, as illustrated for equation 3 by the implementation of the method setInitial at http://bit.ly/1Yosos6. All initial parameterization procedures, are kept alongside the version controlled in the public github repository https://github.com/kinome.

These modules were combined with the following visualization libraries: Google chart tools [26], jqmath [27], bootstrap [28] and jQuery [29] to create a tool to visualize individual curve fits. This is available at http://bit.ly/kinomic and shown in Figure 2. This represents a small example of these tools as they were applied to the remainder of the data.

Figure 2.

Figure 2

Screenshot of http://kinome.github.io/demo-cf/#model. The pictured tool is able to compare the three models utilizing any sample data. The top left is the editable data, the top right is the equation selection tool, and the bottom is the data and curve fit. Data is interactive, data points can be removed by clicking them, and their x, y-values are displayed on mouse over.

Model identification

Thirty-six samples ran utilizing protein tyrosine kinase (PTK) chips were selected to represent the global analytical space. These samples were selected to cover the spectrum of good to bad signal observations. These kinomic experiments included lysates derived from short-term frozen primary human tumor tissue, long term frozen primary human tumor tissue, and freshly lysed cultured human tumor and non-tumor cells. Lysates treated both in vitro, and ex vivo (on chip) with kinase inhibitors were included. More information on samples selected can be found in Table S1.

Quality control

Since poor data fitting can be due to a number of problems, we selected only the data sets that had a Wald-Wolfowitz (WW) runs test with a p-value ≥ 0.05 for all three models. This choice was based on experimentation comparing this selection method to R2 (Figure S1). This reference data was converted into density scores using the Matlab package kde [30] (available at: http://bit.ly/kde_botev).

Technical replicates

Two sets of 6 technical replicates for PTK data that passed QC as described above individually for models 2 and 3 (results) were selected for analysis. The values were exported, and the reproducibility of key parameters along with the calculated vini for model 2 (results) were investigated using transformed non-parametric quantile data for each set of replicates. This data was then converted to density measurements using Kernal Density Estimation [31] with Parzen–Rosenblatt rule of thumb window.

Results

The data analysis that produced the results described in this section can be reproduced for arbitrary datasets by using the web application at http://bit.ly/kinomic, depicted in Figure 2. As detailed in the methods, no data is transferred out of the user’s web browser - all computation happens in the browser, and the code can be inspected by opening the developer tools or by utilizing the github repository (for example, see https://developer.chrome.com/devtools for Google Chrome, or https://developer.mozilla.org/en-US/docs/Tools for Mozilla Firefox).

Model identification

The PamGene kinase peptide arrays generate two unique sets of fluorescence intensity data for each sample run: a post-wash linear series and a nonlinear time progression. The post-wash linear data is obtained by varying the camera exposure time following washing off of remaining sample and reagents. The time series data however, is obtained as the reaction progresses at set intervals based on the number of cycles the machine has run. Three models were investigated: a simple negative exponential (equation 1), a background corrected (c0) variation of the negative exponential (equation 2) and a background corrected (c0) rational hyperbolic (equation 3).

y=y0+ymax·(1-e-k·c) (1)
y=y0+ymax×(1-e-k·(c-c0)) (2)
y=ymax·vi·(c-c0)ymax+vi·(c-c0) (3)

In each of these models, y represents the amount of phosphorylation measured as median signal minus the background, at cycle number, c. The value ymax is the upper asymptotic value y can reach, whereas vi is initial slope of y and k represents the rate of exponential growth. Equation 3 was derived as follows:

y=vi·c[Linearaccumulationofaphosphorylatedproductc:dy/dc=vi]y=vi·c(1-y/ymax)[Limited]y=vic-vicyymaxy(1+vicymax)=vicy=((vic)-1+ymax-1)-1y=ymax·vi·(c-c0)ymax+vi·(c-c0)

Due to the rate of asymptotic approarch being higher in an exponential equations than in a rational ones all data will produce different ymax predictions based on whether model 1/2 or model 3 is utilized. Since this is a predictive term and by definition never truly reached it cannot be expected to be accurate and should not be used for comparisons.

Model identification

The thirty-six samples analyzed to represent the global analytical space generated 5184 time series (36 series x 144 kinases). Each of them was parameterized for each of the 3 equations. Of those, 2863 (55%) had a Run’s test p-value ≥ 0.05 across all three models, (eq1 2924, eq2 3142, eq3 3342) passing quality control (see Methods). Figure 3a shows the distribution of residuals across this sample data (37,219 points x 3 models). Peak densities were as follows, eq1-0.142, eq2-0.150, eq3-0.165. This suggests that model 3 offers a better description of the kinomic signal (See Discussion). That superiority is reinforced by the distribution of the sum of square deviations for each fit (2863 points x 3 models) depicted in Figure 3b, where equation 3 is observed to lead to narrower residual distributions. Peak residual densities occurred at the following points: eq1- (60.7, 0.00866); eq2- (56.8, 0.00932); eq3- (52.8, 0.0112). While the differences presented are minor, it is important to note that equation 3 improves upon equation 2 while reducing the number of parameters from 4 to 3.

Figure 3.

Figure 3

Graphical representation of residual variation in background fluorescence versus cycle (see Figure 2) for the three models. eq3 can be seen as the solid blue line in both panels of the figure as the highest peak. eq2, and eq1 peak lower respectively and can be seen to follow eq3 as a dotted and a slash dot line in both panels. These lines were generated by fitting 36 PTK experiments (see Methods) to all three models. Following quality control 2863 fits remained across all three models; deviations were calculated and plotted for density.

Reproducibility

The variability of the kinomic signal was assessed by analyzing two sets of 6 technical replicates. Based on the above results models 2 and 3 were investigated for the reproducibility of their key parameters. Each model was filtered individually by QC (methods), and then vini, the value typically utilized in current publications, was calculated for model 2 as follows:

vini=y(35)=ymax·k·e-k·(35-c0)

These values were non-parametrically pre-processed by replacing raw values by the corresponding quantiles, for k, vini and ymax from model 2 and vi and ymax from model 3. The combined sets of technical replicates had the following quantile-quantile correlations: cor(q – q: equation 2, k) =0.7101; cor (q – q: equation 2, ymax) =0.8569; cor (qq: equation 2, vini) =0.9359 (not pictured); cor (q – q: equation 3, vi) =0.9352, cor (qq: equation 3, ymax) =0.7751. Equation 2 had a total of 1252 (of 1728) successful fits and Equation 3 had a total of 1503 (of 1728) successful fits. The results obtained are presented in Figure 4. These results indicate ymax is more reproducible for model 2 than model 3. However the stability of this parameter is low for both models. This instability is due to the large number of curves produced remaining in a near linear or linear phase. This results in ymax values that far exceed the boundaries of the data presented and reinforces the idea that ymax should not be utilized for comparative analysis. The reproducibility of the key parameter for equation 3 (vi) is a substantial improvement over the key parameter for equation 2 (k). Interestingly, the reproducibility of vini as calculated from equation 2 is a slight improvement (Correlation difference of 0.005) over that of the vi from equation 3. More importantly, vini is more reproducible than the parameters utilized to calculate it. This indicates that the parametric stability for equation 2 is low even though the estimation early slope is stable.

Figure 4.

Figure 4

Analysis of reproducibility of parameterizations in two 6 replicate sets. Ideally all data sits on the dashed 1-1 line. Color represents relative density with red being the highest. Panel A is the key parameter k for equation 2 (results) and has a Spearman’s rank correlation of 0.7101. Panel B is the key parameter vi for equation 3 (results) and has a Spearman’s rank correlation of 0.9352. Panel C is the predictive parameter ymax for equation 2 (results) and has a Spearman’s rank correlation of 0.8569. Panel D is the predictive parameter ymax for equation 3 and has a Spearman’s rank correlation of 0.7751. These were produced across 144 peptides, with 12 technical replicates, after filtering for high quality fits (See Methods) this created 5306 points (of a possible 8640) for panels A/C and 6802 (of a possible 8640) for panels B/D. k/vi are the critical values for defining the curves.

Discussion

The kinome represents a very functional subset of the genome and is of high interest to academia and pharma. Kinases are highly druggable and kinase targeted agents have generated very promising results in the clinic, particularly in proliferative diseases. However, the enzymatic nature and “promiscuity” of kinases produces significant challenges to studying the kinome. Indeed, an individual kinase typically targets multiple substrates with varying affinities while substrates are often targeted by more than one kinase. Enzymatically, this can be seen in the non-linear curves generated by the time series PamStation data. The velocity of the reaction and shape of the curve will vary based on the kinase (or kinase family) and substrate affinities. Biologically, this manifests as molecular redundancy where multiple signals can converge on the same target protein.

Of the three models investigated the three-parameter rational model for eq3 most closely described the data for the following reasons:

  1. Having the highest peak for the deviation plot and for the model sum of square deviations (Figure 3).

  2. Having the highest success rate using the curve fitting algorithm, 64.5% (+3.9% over eq2, mixed quality data), and 87.0% (+14.5% over eq2, high quality data) as determined by WW runs test (Methods). This indicates a higher randomness in the non-parametric distribution of residuals for eq3.

  3. Utilizing only three parameters to describe the model. Based on the above metrics, the four-parameter exponential model (eq2) is the second best option; however the higher number of parameters reinforces the use of eq3.

  4. Having the key parameter with the highest reproducibility. The reproducibility of the key parameter, vi from model 3 is significantly higher than that of k from model 2 (+31.7%).

  5. Qualitatively, rational models are commonly used in enzyme kinetics with one limiting reaction, while exponential models are utilized for first order reaction with one reagent.

Generally adding parameters to a model decreases the error in residuals by allowing additional variability to be accounted for. However when moving from the four-parameter eq2 to the three-parameter eq3, we do not see worsening of residuals, nor a decrease in reproducibility. In fact we observe the opposite. This decrease in parameter space becomes particularly important when considering individual fits contains only 13 points. This move then represents an 11% increase in the degrees of freedom with an overall improvement in multiple goodness-of-fit metrics. It is important to note, previously published kinetic studies focus on the calculated value: vini. Our analysis indicates, when calculated from eq2, the reproducibility of vini is nearly equivalent to that of the comparable parameter, vi from eq3. Once again, eq3’s use of one less parameter to produce equivalent or improved parameterization solidifies the suggested use of eq3.

This is the first time, to the authors’ knowledge, that even a preliminary assessment of the variability and reproducibility of the PamGene PamChip® has been investigated in the literature. Since future goals include tailoring cancer treatments to patients, a thorough investigation of this nature is necessary. In addition to the reproducibility of the data itself, the reproducibility and accuracy of the analysis itself is equally important. To this end all data analysis procedures were coded as web applications - that is, they are available as JavaScript scripts, in the open source and versioned environment of GitHub (see results and methods). The relevant feature of this approach, which we have explored and discussed in bioinformatics applications ranging from image analysis [32] to sequence analysis [33], is that the analysis can be repeated in any web browser, with easily open reviewable code, and without need to download nor install any components. In a nutshell, this creates lasting reproducibility that does not depend on server-side resources maintained by the authors of this report, nor requires any client-side configuration by users of the tools.

Conclusion

Kinomic signals, as assessed by the PamGene platform, are accurately described as a rational hyperbolic function, not dissimilar in shape to Michaelis–Menten. This conclusion is presented here not as an alternative to noise filtering approaches followed by some software packages but, on the contrary, to inform the noise structure associated with the kinomics signal. Our original hypothesis that a non-exponential model would be provide a superior parameterization has been verified by an at least equivalent fit with a smaller parameter space, an essential characteristic given the limited data points per fit. A web application was developed and is made publicly available in an open source format to allow dissemination of libraries needed to parameterize the corresponding hyperbolic model. The reliance on the scripting language of the web, JavaScript, to develop those libraries, and depositing them in versioned GitHub pages is argued to maximize the reproducibility and reuse of the libraries developed. The main remaining challenge of the parameterization of kinomics signals appears to be associated with the robustness of the non-linear regression. Improvements in the parameterization procedure will decrease the number of individual kinomic signals that currently do not pass quality control.

Supplementary Material

Suppl

Acknowledgments

We would like to thank Egiebade E. Iriabho and Sean Wilkinson from UAB for programming advice; Faris Naji and Alex Maurel from PamGene® for advice with interacting with BioNavigator® and PamGene® data; and the UAB Kinome Core (http://www.kinomecore.com/) for continued support, advice, and access to data. Partially supported by NIGMS MSTP T32GM008361.

References

  • 1.Zhang H, Zha X, Tan Y, Hornbeck PV, Mastrangelo AJ, et al. Phosphoprotein analysis using antibodies broadly reactive against phosphorylated motifs. J Biol Chem. 2002;277:39379–39387. doi: 10.1074/jbc.M206399200. [DOI] [PubMed] [Google Scholar]
  • 2.Hopkins AL, Groom CR. The druggable genome. Nat Rev Drug Discov. 2002;1:727–730. doi: 10.1038/nrd892. [DOI] [PubMed] [Google Scholar]
  • 3.Arsenault R, Griebel P, Napper S. Peptide arrays for kinome analysis: new opportunities and remaining challenges. Proteomics. 2011;11:4595–4609. doi: 10.1002/pmic.201100296. [DOI] [PubMed] [Google Scholar]
  • 4.Carpay WM, Papen RF. Analytical test device with substrate having oriented through going channels and improved methods and apparatus for using same. US; 2002. [Google Scholar]
  • 5.Ubersax JA, Ferrell JE., Jr Mechanisms of specificity in protein phosphorylation. Nat Rev Mol Cell Biol. 2007;8:530–541. doi: 10.1038/nrm2203. [DOI] [PubMed] [Google Scholar]
  • 6.Hilhorst R, Houkes L, Mommersteeg M, Musch J, van den Berg A, et al. Peptide Microarrays for Profiling of Serine/Threonine Kinase Activity of Recombinant Kinases and Lysates of Cells and Tissue Samples. In: Bina M, editor. Gene Regulation: Methods and Protocols. Humana Press; Totowa, NJ: 2013. [DOI] [PubMed] [Google Scholar]
  • 7.Marballi KK, McCullumsmith RE, Yates S, Escamilla MA, Leach RJ, et al. Global signaling effects of a schizophrenia-associated missense mutation in neuregulin 1: an exploratory study using whole genome and novel kinome approaches. J Neural Transm (Vienna) 2014;121:479–490. doi: 10.1007/s00702-013-1142-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.McGuire JL, Hammond JH, Yates SD, Chen D, Haroutunian V, et al. Altered serine/threonine kinase activity in schizophrenia. Brain Res. 2014;1568:42–54. doi: 10.1016/j.brainres.2014.04.029. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Duverger A, Wolschendorf F, Anderson JC, Wagner F, Bosque A, et al. Kinase control of latent HIV-1 infection: PIM-1 kinase as a major contributor to HIV-1 reactivation. J Virol. 2014;88:364–376. doi: 10.1128/JVI.02682-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Anderson JC, Willey CD, Mehta A, Welaya K, Chen D, et al. High throughput kinomic profiling of human clear cell renal cell carcinoma identifies kinase activity dependent molecular subtypes. PLoS One. 2015;10:e0139267. doi: 10.1371/journal.pone.0139267. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Anderson JC, Duarte CW, Welaya K, Rohrbach TD, Bredel M, et al. Kinomic exploration of temozolomide and radiation resistance in glioblastoma multiforme xenolines. Radiother Oncol. 2014;111:468–474. doi: 10.1016/j.radonc.2014.04.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Stoltz K, Sinyuk M, Hale JS, Wu Q, Otvos B, et al. Development of a Sox2 reporter system modeling cellular heterogeneity in glioma. Neuro Oncol. 2015;17:361–371. doi: 10.1093/neuonc/nou320. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Anderson JC, Minnich DJ, Dobelbower MC, Denton AJ, Dussaq AM, et al. Kinomic profiling of electromagnetic navigational bronchoscopy specimens: a new approach for personalized medicine. PLoS One. 2014;9:e116388. doi: 10.1371/journal.pone.0116388. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Folkvord S, Flatmark K, Dueland S, de Wijn R, Grøholt KK, et al. Prediction of response to preoperative chemoradiotherapy in rectal cancer by multiplex kinase activity profiling. Int J Radiat Oncol Biol Phys. 2010;78:555–562. doi: 10.1016/j.ijrobp.2010.04.036. [DOI] [PubMed] [Google Scholar]
  • 15.Saelen MG, Flatmark K, Folkvord S, de Wijn R, Rasmussen H, et al. Tumor kinase activity in locally advanced rectal cancer: angiogenic signaling and early systemic dissemination. Angiogenesis. 2011;14:481–489. doi: 10.1007/s10456-011-9231-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Versele M, Talloen W, Rockx C, Geerts T, Janssen B, et al. Response prediction to a multi-targeted kinase inhibitor in cancer cell lines and xenograft tumors using high-content tyrosine peptide arrays with a kinetic readout. Mol Cancer Ther. 2009;8:1846–1855. doi: 10.1158/1535-7163.MCT-08-1029. [DOI] [PubMed] [Google Scholar]
  • 17.Van Beuningen M, Ruijtenbeek R. Google Patents. US: 2006. Novel method for monitoring biomolecular interactions. [Google Scholar]
  • 18.Thilakarathne PJ, Clement L, Lin D, Shkedy Z, Kasim A, et al. The use of semiparametric mixed models to analyze pamchip® peptide array data: An application to an oncology experiment. Bioinformatics. 2011;27:2859–2865. doi: 10.1093/bioinformatics/btr475. [DOI] [PubMed] [Google Scholar]
  • 19.Eilers PH. A perfect smoother. Anal Chem. 2003;75:3631–3636. doi: 10.1021/ac034173t. [DOI] [PubMed] [Google Scholar]
  • 20.Vilela M, Borges CC, Vinga S, Vasconcelos AT, Santos H, et al. Automated smoother for the numerical decoupling of dynamics models. BMC Bioinformatics. 2007;8:305. doi: 10.1186/1471-2105-8-305. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Heinrich R, Neel BG, Rapoport TA. Mathematical models of protein kinase signal transduction. Mol Cell. 2002;9:957–970. doi: 10.1016/s1097-2765(02)00528-2. [DOI] [PubMed] [Google Scholar]
  • 22.Voit EO. Biochemical Systems Theory: A Review. ISRN Biomathematics 2013 [Google Scholar]
  • 23.de Wijn R, Ruijtenbeekert R. PamChip® microarrays and PamStation® instruments; A novel platform to support kinase and kinase inhibitor research 2013 [Google Scholar]
  • 24.Naji F, de Wijn R, Maurel A. BioNavigator, software to interpret PamChip® measurements. PamGene International B.V; 2013. [Google Scholar]
  • 25.Hickson I. Web Workers. 2015. [Google Scholar]
  • 26.Google chart tools. 2015. [Google Scholar]
  • 27.Barton D. jqMath - Put Math on the Web. 2009. [Google Scholar]
  • 28.Otto M, Thornton J. Bootstrap. 2015. [Google Scholar]
  • 29.Resig J. j Team, jQuery 2.1.4, write more, do less. 2015. [Google Scholar]
  • 30.Botev ZI, Grotowski JF, Kroese DP. Kernel density estimation via diffusion. Annals of Statistics. 2010;38:2916–2957. [Google Scholar]
  • 31.Ihler A. Kernel Density Estimation Toolbox for MATLAB (R13) 2003. [Google Scholar]
  • 32.Almeida JS, Iriabho EE, Gorrepati VL, Wilkinson SR, Grüneberg A, et al. ImageJS: Personalized, participated, pervasive, and reproducible image bioinformatics in the web browser. J Pathol Inform. 2012;3:25. doi: 10.4103/2153-3539.98813. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Almeida JS, Grüneberg A, Maass W, Vinga S. Fractal MapReduce decomposition of sequence alignment. Algorithms Mol Biol. 2012;7:12. doi: 10.1186/1748-7188-7-12. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Suppl

RESOURCES