Skip to main content
Clinical Orthopaedics and Related Research logoLink to Clinical Orthopaedics and Related Research
. 2016 Apr 22;474(10):2181–2187. doi: 10.1007/s11999-016-4811-6

Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA

Morad Chughtai 1, Jaydev B Mistry 1, Aloise M Diedrich 1, Julio J Jauregui 1, Randa K Elmallah 1, Peter M Bonutti 2, Steven F Harwin 3, Arthur L Malkani 4, Frank R Kolisek 5, Michael A Mont 1,
PMCID: PMC5014802  PMID: 27106128

Abstract

Background

Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting.

Questions/purposes

(1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA?

Methods

Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded.

Results

The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494–4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and stem; and two patients had periprosthetic infections that were treated with two-stage revisions. There were no dislocations. Patients had a mean HHS of 94 (SD, 6) at final followup. On radiographic evaluation, no progressive radiolucencies or positional changes of the components were identified. Surgical complications included one traumatic avulsion of the abductors, one traumatic avulsion of the greater trochanter, which was repaired without revision of any of the components, and one loose femoral stem, which required revision of the femoral component only.

Conclusions

Dual-mobility cups in primary THA yield seemingly comparable survivorship and complications to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings, larger, longer term, comparative–and ideally, randomized–trials will be needed to establish the superiority of one approach over the other. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols.

Level of Evidence

Level IV, therapeutic study.

Introduction

Dislocation after THA remains a prominent concern, because its frequency is reported to range from 1% to 5% [4, 25]. With the increasing utilization rates of THAs [28], there is also an expected subsequent rise in the number of dislocations. Numerous factors may contribute to the frequency of this complication, including component design, patient characteristics, and surgical technique [27]; it still results in many major revision procedures.

To improve stability, implant modifications have included the use of constrained acetabular liners and large-diameter femoral heads. However, although constrained liners may aid in soft tissue tensioning and be cost-effective, they have been associated with a high risk of failure [12]. In addition, although large-diameter femoral heads, particularly those greater than 32 mm, are associated with greater impingement-free ROM [9] and a lower dislocation risk [4, 7], these designs are not as effective in decreasing instability as once hoped nor can they be used in all patients as a result of size limitations. Furthermore, both constrained liners and large-diameter femoral heads have been linked to complications such as accelerated polyethylene wear rates and altered bone-prosthesis osseointegration [22, 30]. Because of these, dual-mobility articulations have emerged as a potential solution for THA instability. These articulations work by containing a three-component and three-joint system: a socket, a free (not fixed) polyethylene liner, and a head. Dual-mobility articulations are commonly used in the revision setting [17]; however, there is a relative paucity of studies evaluating their use in primary THA [3, 5, 6, 8, 10, 11, 13, 15, 16, 20, 24, 26]. The present study similarly evaluates a dual-mobility articulation; however, it is different in design from most of the aforementioned studies. Although there are advantages to this design, it is not without its disadvantages such as polyethylene wear and intraprosthetic dislocation (IPD) (unique to these articulations). Intraprosthetic dislocation may lead to others such as femoral head wear, metallosis, and impingement, which may cause implant failure and necessitate revision surgery [1, 2, 14, 16, 18, 19, 21, 23].

Therefore, we asked: (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA?

Patients and Methods

We retrospectively evaluated longitudinally maintained databases from five institutions, which contained all patients undergoing primary THA who had dual-mobility articulations between January 2011 and December 2013.

During this study period, the five participating surgeons performed 495 cementless primary THAs. Patients who (1) underwent primary cementless THA; (2) had dual-mobility articulations; and (3) had a minimum followup of 2 years were included in this study. Of the 495 patients, 453 (92%) were performed using the dual mobility. One of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 453 patients on whom this device was used on, 43 patients (10%) were lost to followup before the 2-year minimum. Four hundred ten patients were included in the analysis (164 men, 246 women) who had a mean age of 64 years (SD, 12 years) and a mean body mass index of 31 kg/m2 (SD, 7 kg/m2) (Table 1). The mean followup was 3 years (SD, 0.7 years). Patient data were collected preoperatively and at yearly followup points thereafter. Demographic, clinical, radiographic, and patient-reported outcomes were obtained from medical records, pre- and postoperative evaluations, and office charts.

Table 1.

Baseline characteristics of the primary modular dual-mobility cohort

Demographic characteristic Number (%)
Total 410
Sex
 Men 164 (40)
 Women 246 (60)
Body mass index (kg/m2) (SD) 31 (7)
Age (years) (SD) 64 (12)
Harris hip score (range) 51 (15)

All of the primary THAs were performed by five fellowship-trained, adult reconstructive surgeons (MAM, SFH, ALM, FRK, PMB). In addition to undergoing a cementless primary THA with dual-mobility articulations (Modular Dual Mobility; Stryker, Mahwah, NJ, USA), all patients received uncemented tapered-wedge femoral components with circumferential plasma spray coating and hydroxyapatite (Accolade TMZF or Accolade II; Stryker).

The dual-mobility articulations used in this study consisted of three components: a socket, a free (not fixed) polyethylene liner, and a metal head. The acetabular shell consists of titanium alloy with a porous, plasma-sprayed coat of titanium and hydroxyapatite on the outer surface, and a bearing surface of cobalt-chrome with screw holes for additional fixation, if deemed necessary by the surgeon. The polyethylene liner in the articulation consisted of highly crosslinked, ultrahigh-molecular-weight polyethylene.

All procedures were performed through the anterolateral approach. For all patients, the surgeons aimed to achieve proper hip biomechanical properties by maintaining the center of rotation of the hip. Intraoperatively, after placing the components, stability was confirmed by ensuring that no dislocation occurred during assessment of functional ROM (30° of hip abduction and adduction, 40° of internal and external rotation, and greater than 110° of flexion). All surgeons aimed to place the cups with a less than 45° acetabular opening angle; however, angular measurements were not recorded.

Variables collected included age, gender, body mass index, laterality of surgery, followup dates, revision surgeries, radiographic assessments, complications, and Harris hip scores (HHS). These data were gathered from medical records, pre- and postoperative evaluations, and office charts.

Statistical Analysis

Using the Kaplan-Meier analysis, survivorship to aseptic failure and all-cause survivorship of the cup were calculated to assess acetabular component longevity. Clinically, functional outcomes were assessed using the HHS system. These scores were recorded preoperatively and yearly thereafter. At latest followup, the mean HHS was determined.

For radiographic analysis, standard AP radiographs of the hip and Lauenstein lateral radiographs were obtained ad hoc and evaluated postoperatively and at 1- and 2-year visits by the operating surgeons to assess for cup migration, progressive radiolucencies, or positional changes in the cup or stem. In addition, we assessed the femoral component for circumferential radiolucencies on the femoral side in addition to subsidence and angular change. Assessments of the radiographs were performed by five of the authors (PMB, SFH, ALM, FRK, MAM). Component loosening was defined as the presence of subsidence of (> 2 mm) or an angular shift (> 3°) [29]. Progressive radiolucency was defined by location, size, and temporal progression. If nonprogressive radiolucency was found in the postoperative radiograph, it was not considered a complication. If a radiolucency progressed by > 1 mm in any of the zones around the acetabulum or femur, it was considered osteolysis.

Any complications related to the procedure were assessed and recorded, and they were categorized as either surgical or medical complications. In addition, we performed descriptive statistics to assess frequencies of complications.

All data were collected and entered into an Excel spreadsheet (Microsoft Corporation, Redmond, WA, USA). Statistical analysis was performed using SPSS (IBM Corporation, Armonk, NY, USA). A cutoff p value of < 0.05 was set to determine statistical significance.

Results

The survivorship to aseptic failure (n = 1) (Fig. 1) and all-cause (aseptic, n = 1; septic, n = 2) (Fig. 2) Kaplan-Meier acetabular component survivorship were 99.8% (95% confidence interval [CI], 4.517–4.547) and 99.3% (95% CI, 4.494–4.543). There was one aseptic and two septic revisions. One hip had trunnion notching caused by impingement of a malpositioned cup, which resulted in revision of the cup and stem. Two patients developed a late infection, which were both treated with two-stage revision procedures.

Fig. 1.

Fig. 1

The acetabular component aseptic survivorship is demonstrated using a Kaplan-Meier curve.

Fig. 2.

Fig. 2

The acetabular component all-cause survivorship is demonstrated using a Kaplan-Meier curve.

With regard to clinical outcomes, the mean HHS at final followup was 94 points (SD, 6). Two patients reported HHS of ≤ 70. One patient did not have complications; however, the other patient was found to have a loose femoral stem, which is described subsequently.

On radiographic evaluation at 6-week and latest followup (3 years; SD, 0.7 years), no implants had a change in position in comparison to films taken within 6 weeks of surgery. There was no evidence of progressive radiolucencies.

Seven patients experienced complications. Surgical complications included one traumatic avulsion of the greater trochanter, which was repaired using a Dall-Miles cable system (Stryker). This did not result in revision of any of the components and the patient had a HHS of 96 at 24-month followup. One patient had a loose femoral stem, which was revised with a modular stem. This patient had a HHS of 64 at 36-month followup. One patient had traumatic avulsion of the abductor muscles, which was treated with surgical repair. This patient had a HHS of 100 at 3-year followup. No patients in the series had a dislocation. Three patients developed deep vein thromboses and one patient had pulmonary embolism. All were treated pharmacologically and had no subsequent events.

Discussion

Dual-mobility articulations may help decrease instability after THA [3, 5, 6, 8, 10, 11, 13, 15, 16, 20, 24, 26]. This is likely the result of the increased effective size of the femoral head as well as the expanded impingement-free ROM. There is a relative paucity of studies evaluating their use in primary THA [3, 5, 6, 8, 10, 11, 13, 15, 16, 20, 24, 26]. In the present study, we similarly evaluated a dual-mobility articulation; however, it is different in design from most of the aforementioned studies. Although there are advantages to dual-mobility implants, they are not without disadvantages such as polyethylene wear, loosening, and the unique complication of IPD [1, 2, 14, 16, 18, 19, 21, 23]. We therefore asked: (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA?

There are several limitations to this study. Even with 410 patients, the study was not large enough to comment on the true frequency of an uncommon event like dislocation. Although increasing the cohort size would be ideal, we feel that this article can serve as a starting point for other studies to see the short- to midterm results of this device. Additionally, it is important to note that 10% of patients were lost to followup; therefore, there may have been complications such as dislocation that were not captured. Patients with smaller acetabula were excluded by four of the five surgeons, which should be considered when interpreting the results. Furthermore, outcomes were assessed using only one questionnaire (HHS). However, the HHS contains subjective and objective parameters, thereby providing reasonable assessment of the patient. Moreover, this study had only a short followup period; therefore, it is important to emphasize the survivorship, minimal complications, and lack of IPD in this study may be a function of time and could potentially be unmasked by a longer followup study. Additionally, problems such as osteolysis or loosening may arise in the future, but could not be detected with a short-term study. Thus, our followup demonstrates that the short-term results with this device are no worse than what is on the market already. Although this study is similar to other studies in its evaluation of the dual-mobility articulations, it extends the current literature by evaluating a design that is different from that of most other studies (Table 2).

Table 2.

Studies assessing dual mobility articulations in primary THA

Author, year (arranged chronologically) Sample size Minimum followup (years) Cup Dislocation (%) Fixation technique Polyethylene type
Farizon et al., 1998 [13] 135 10 Novae-1 cup (Orthodynamics Ltd, Gloucestershire, UK) 0.7 Cementless N/A
Guyen et al., 2007 [15] 167 2 Saturne cup (Amplitude, Neyron, France) 0 Cementless HMWPE
Bauchu et al., 2008 [3] 150 6 (mean) Third-generation POLARCUP (Smith & Nephew Orthopaedics AG, Rotkreuz, Switzerland) 0 N/A N/A
Hamadouche et al., 2012 [16] 168 5 Tregor unconstrained tripolar cup (Aston Medical, Saint Etienne, France) 2 Cementless UHMWPE
Bouchet et al., 2011 [5] 105 1 Novae (Orthodynamics Ltd); Stafit (Zimmer GmbH, Winterthur, Switzerland); Avantage (Biomet, Valence, France); Gyros cups (DePuy, Warsaw, IN, USA) 0 Cementless Not specified
Boyer et al., 2012 [6] 240 19 Novae tripodal (SERF) (Orthodynamics Ltd) 0 Cementless UHMWPE
Prudhon et al., 2013 [26] 105 8 (median) Quattro® (Groupe Lépine, Genay, France) 0.9 Cemented UHMWPE
Epinette et al., 2014 [11] 437 2 Restoration ADM acetabular system (Stryker Orthopaedics, Mahwah, NJ, USA) 0 Cemented HXLPE
Caton et al., 2014 [8] 105 10 Quattro® (Groupe Lépine, Genay, France) 0.9 Cemented Standard
Epinette, 2015 [10] 143 2 Restoration ADM acetabular system (Stryker Orthopaedics) 0 Cementless HXLPE
Mohammed et al., 2015 [20] 20 0.5 Serf Novae® Dual Mobility Acetabular cup (Orthodynamics Ltd) 0 Both Not specified
Chughtai et al.* 410 2 Modular Dual Mobility (Stryker Orthopaedics) 0 Cementless UHMWPE

* The present study; UHMWPE = ultrahigh-molecular-weight polyethylene; HXLPE = highly crosslinked polyethylene; N/A = not available.

Several other studies have also illustrated good aseptic survivorship and lower dislocation proportion with the use of dual-mobility articulations in primary THAs (Table 2). In an analysis of 384 dual-mobility hips, Philippot et al. [24] observed a 4% dislocation proportion and cup survivorship of 97% at a minimum followup of 12 years. Similarly, Farizon et al. [13] conducted a study examining 135 cementless dual-mobility hips and found a 0.7% dislocation proportion at a minimum followup of 10 years with 95% implant survivorship at 12 years. In addition, Epinette [10] analyzed 143 cemented dual-mobility primary THAs, which showed 100% survivorship at minimum of 2 years postoperatively with no reported dislocations. Additionally, Hamadouche et al. [16] reviewed 168 cementless dual-mobility hips and found that 2% experienced dislocation at a minimum followup of 5 years with a survivorship proportion of 94% at 7 years. In an analysis of 150 dual-mobility hips, Bauchu et al. [3] reported that no patients experienced dislocation at a mean followup of 6 years. At 7 years, the proportion of cup survivorship was 97%. Similarly, Boyer et al. [6] analyzed 240 cementless dual-mobility hips and found no dislocations with 80% cup survivorship at a minimum followup of 18 years. Furthermore, Guyen et al. [15] performed a study on 167 dual-mobility hips and reported no dislocations at a minimum followup of 2 years with a 5-year cup survivorship proportion of 96%. Moreover, Epinette et al. [11] analyzed 437 primary cemented THAs and noted a 100% cup survivorship for patients younger than 70 years of age and 99.7% for patients older than 70 years of age at minimum 2-year followup.

Similar to our study, Boyer et al. [6] reported a final followup mean HHS of 92 (SD, 1.9) in their retrospective study of 240 hips with a minimum followup of 18 years. Bauchu et al. [3] also reported an improvement in the mean Postel-Merle d’Aubigne score (from 9 to 17) in their study of 150 dual-mobility hips. Guyen et al. [15] reported improvement in HHS from preoperatively (mean, 40; range, 11–100) to 83 (range, 25–100) at the latest followup. Similarly, in the Epinette et al. [11] study, they reported mean HHS of 98 and 82 for the < 70 years of age and ≥ 70 years of age cohorts at final followup, respectively. In the Hamadouche et al. [16] study, the mean Merle d’Aubigné functional hip score increased from 11 (range, 6–16) preoperatively to 17 (range, 9–18) at latest followup.

Several studies have reported on radiographic findings of dual-mobility hips. Boyer et al. [6] radiographically analyzed 89 dual-mobility hips in their minimum 18-year followup study. They found two osteolytic lesions in De Lee and Charnley Zone I (3%) and six in Zone III (10%). However, implant loosening was not found. Additionally, a broken screw was found in one of the hips with Zone I osteolysis. Guyen et al. [15] reported migration of one (0.6%) noncemented acetabular component in addition to three fully hydroxyapatite-coated femoral components. As expected, because of short followup (range, 2–5 years), no tilting, migration, or IPD was recorded in the Epinette et al. [11] study. Similarly, in a study of 20 primary THAs in patients who received dual-mobility cups by Mohammed et al. [20], there was no evidence of loosening. In the Prudhon et al. [26] study, radiographic evaluation at the final followup did not reveal any cup migration or loosening. Of the 119 acetabular components in the Hamadouche et al. [16] study, there were no cases of cup migration. The Boyer et al. [6] study reported that 20 dual-mobility hips were revised because of cup aseptic loosening (8%), two hips were revised for septic loosening (0.8%), and 10 hips were revised for retentive failure (4%). Additionally, five hips were revised because of excessive liner wear (2%). Similarly, Bauchu et al. [3] reported revising two of their cups (1%) secondary to aseptic loosening. In the Epinette et al. [11] study, there was only a single patient with cup loosening; however, as mentioned before, it could be the result of the short followup in this study. Similarly, in the Prudhon et al. [26] study, the two (2%) acetabular component revision operations were required related to loosening. The first case was because of aseptic loosening secondary to a Vancouver Type B fracture. The other case was secondary to septic loosening.

In terms of complications, Guyen et al. [15] reported five (3%) intraoperative fractures and one (0.6%) postoperative periprosthetic fracture of the femur.. In the Farizon et al. [13] study, four implants (3%) were revised for mechanical failure after aseptic displacement of the cup. In the Hamadouche et al. [16] study, there four cases (2%) of IPD; orthopaedic surgeons should be aware of this complication associated with dual-mobility hips. During revision procedures, Langlois et al. [18] have described a case of a dual-mobility articulation with a dislodged femoral head with loss of sphericity secondary to IPD. Similarly, Banzhof et al. [2] also experienced a dislodged femoral head in a revised THA after attempting to reduce a dislocation with this device. Mohammed et al. [19] have reported severe metallosis after IPD in their case of a primary THA performed with a dual-mobility cup. Several other case reports have also demonstrated the potential complications of these designs [1, 2, 14, 16, 18, 19, 21, 23]. Further studies detail this important complication of dual-mobility articulations. In the present study, we experienced a single case of impingement, which is a complication that has been reported in other studies [16, 18].

Although not a variable in the present study, polyethylene wear was noted in several of the aforementioned studies. In the Hamadouche et al. [16] study, they used ultrahigh-molecular-weight polyethylene and found their revised inserts to have macroscopic signs of wear. Epinette [10] used highly crosslinked polyethylene and found a mean wear proportion of 0.03 mm per year in their cementless dual-mobility study. This may be the result of the frictional forces experienced at both interfaces of the polyethylene insert in dual-mobility articulations.

In this series, we found survivorship and complications similar to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings [1, 2, 14, 16, 18, 19, 21, 23], larger, longer term, comparative–and ideally, randomized–trials will be needed to establish the superiority of one approach over the other. National registries may also help to inform this choice, and we look forward with interest to reports of the world’s registries on this topic. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols [3, 5, 6, 8, 10, 11, 13, 15, 16, 20, 24, 26]. Future research should be prospective, comparative, include larger sample sizes, and have longer term followup to evaluate the true outcomes of modular dual-mobility articulations.

Footnotes

One of the authors certifies that he (PMB) has received or may receive payments, during the study period, an amount of USD 100,000 to USD 1,000,000 from Stryker Orthopaedics (Mahwah, NJ, USA) and an amount of USD 10,000 to USD 100,000 from Joint Active Systems (Effingham, IL, USA). One of the authors certifies that he (SFH) has received or may receive payments, during the study period, an amount of USD 100,000 to USD 1,000,000 from Stryker Orthopaedics, less than USD 10,000 from Slack Inc (Thorofare, NJ, USA), an amount of USD 10,000 to USD 100,000 from Convatec, and less than USD 10,000 from Thieme Inc (New York, NY, USA). One of the authors certifies that he (ALM) has received or may receive payments, during the study period, an amount of USD 100,000 to USD 1,000,000 from Stryker Orthopaedics. One of the authors certifies that he (FRK) has received or may receive payments, during the study period, an amount of USD 100,000 to USD 1,000,000 from Stryker Orthopaedics and an amount of USD 10,000 to USD 100,000 from DJ Orthopedics (Vista, CA, USA). One of the authors certifies that he (MAM) has received or may receive payments, during the study period, an amount of USD 100,000 to USD 1,000,000 from Stryker Orthopaedics, an amount of USD 10,000 to USD 100,000 from DJ Orthopedics, an amount of USD 10,000 to USD 100,000 from Microport (Arlington, TN, USA), an amount of USD 10,000 to USD 100,000 from J&J (New Brunswick NJ, USA), an amount of USD 10,000 to USD 100,000 from Medical Compression Systems (Tel Aviv, Israel), an amount of USD 10,000 to USD 100,000 from OnGoing Care Solutions (Pinellas Park, FL, USA), an amount of USD 10,000 to USD 100,000 from Sage Products LLC (Cary, IL, USA), an amount of USD 10,000 to USD 100,000 from TissueGene (Rockville, MD, USA) an amount of USD 10,000 to USD 100,000 from Pacira Pharmaceuticals (Parsippany, NJ, USA), an amount of USD 10,000 to USD 100,000 from Merz (Frankfurt, Germany), and an amount of USD 10,000 to USD 100,000 from Orthosensor (Dania Beach, FL, USA).

All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.

Clinical Orthopaedics and Related Research® neither advocates nor endorses the use of any treatment, drug, or device. Readers are encouraged to always seek additional information, including FDA-approval status, of any drug or device prior to clinical use.

Each author certifies that his or her institution approved or waived approval for the human protocol for this investigation and that all investigations were conducted in conformity with ethical principles of research.

This work was performed at the Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, Sinai Hospital of Baltimore, Baltimore, MD, USA; Bonutti Clinic, Effingham, IL, USA; Mount Sinai Beth Israel, New York, NY, USA; University of Louisville Adult Reconstruction Program, Louisville, KY, USA; and OrthoIndy, Greenwood, IN, USA.

An erratum to this article can be found at http://dx.doi.org/10.1007/s11999-016-4867-3.

References

  • 1.Banka TR, Ast MP, Parks ML. Early intraprosthetic dislocation in a revision dual-mobility hip prosthesis. Orthopedics. 2014;37:e395–397. doi: 10.3928/01477447-20140401-63. [DOI] [PubMed] [Google Scholar]
  • 2.Banzhof JA, Robbins CE, Ven A, Talmo CT, Bono JV. Femoral head dislodgement complicating use of a dual mobility prosthesis for recurrent instability. J Arthroplasty. 2013;28:543.e541–543. [DOI] [PubMed]
  • 3.Bauchu P, Bonnard O, Cyprès A, Fiquet A, Girardin P, Noyer D. The dual-mobility POLARCUP: first results from a multicenter study. Orthopedics. 2008;31(Suppl 2). [PubMed]
  • 4.Berry DJ, von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2456–2463. doi: 10.2106/JBJS.D.02860. [DOI] [PubMed] [Google Scholar]
  • 5.Bouchet R, Mercier N, Saragaglia D. Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res. 2011;97:2–7. doi: 10.1016/j.otsr.2010.07.008. [DOI] [PubMed] [Google Scholar]
  • 6.Boyer B, Philippot R, Geringer J, Farizon F. Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop. 2012;36:511–518. doi: 10.1007/s00264-011-1289-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Bystrom S, Espehaug B, Furnes O, Havelin LI. Norwegian Arthroplasty R. Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register. Acta Orthop Scand. 2003;74:514–524. doi: 10.1080/00016470310017893. [DOI] [PubMed] [Google Scholar]
  • 8.Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R. A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop. 2014;38:1125–1129. doi: 10.1007/s00264-014-2313-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Cooper HJ, Della Valle CJ. Large diameter femoral heads: is bigger always better? Bone Joint J. 2014;96:23–26. doi: 10.1302/0301-620X.96B11.34342. [DOI] [PubMed] [Google Scholar]
  • 10.Epinette JA. Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up. J Arthroplasty. 2015;30:241–248. doi: 10.1016/j.arth.2014.09.022. [DOI] [PubMed] [Google Scholar]
  • 11.Epinette JA, Beracassat R, Tracol P, Pagazani G, Vandenbussche E. Are modern dual mobility cups a valuable option in reducing instability after primary hip arthroplasty, even in younger patients? J Arthroplasty. 2014;29:1323–1328. doi: 10.1016/j.arth.2013.12.011. [DOI] [PubMed] [Google Scholar]
  • 12.Etienne G, Ragland PS, Mont MA. Use of constrained acetabular liners in total hip arthroplasty. Orthopedics. 2005;28:463–469; quiz 470–471. [DOI] [PubMed]
  • 13.Farizon F, de Lavison R, Azoulai JJ, Bousquet G. Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop. 1998;22:219–224. doi: 10.1007/s002640050246. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Fehring KA, Berry DJ. Dissociation and Intrapelvic entrapment of a dual-mobility polyethylene component. Clin Orthop Relat Res. 2016;474:1072–1076. doi: 10.1007/s11999-015-4381-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Guyen O, Pibarot V, Vaz G, Chevillotte C, Carret JP, Bejui-Hugues J. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation. J Arthroplasty. 2007;22:849–858. doi: 10.1016/j.arth.2006.11.014. [DOI] [PubMed] [Google Scholar]
  • 16.Hamadouche M, Arnould H, Bouxin B. Is a cementless dual mobility socket in primary THA: a reasonable option? Clin Orthop Relat Res. 2012;470:3048–3053. doi: 10.1007/s11999-012-2395-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Jauregui JJ, Pierce TP, Elmallah RK, Cherian JJ, Delanois RE, Mont MA. Dual mobility cups: an effective prosthesis in revision total hip arthroplasties for preventing dislocations. Hip Int. 2015:0. [DOI] [PubMed]
  • 18.Langlois J, El Hage S, Hamadouche M. Intraprosthetic dislocation: a potentially serious complication of dual mobility acetabular cups. Skeletal Radiol. 2014;43:1013–1016. doi: 10.1007/s00256-014-1824-7. [DOI] [PubMed] [Google Scholar]
  • 19.Mohammed R, Cnudde P. Severe metallosis owing to intraprosthetic dislocation in a failed dual-mobility cup primary total hip arthroplasty. J Arthroplasty. 2012;27:493.e491–493. [DOI] [PubMed]
  • 20.Mohammed R, Hayward K, Mulay S, Bindi F, Wallace M. Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty. J Orthop Traumatol. 2015;16:9–13. doi: 10.1007/s10195-014-0324-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Odland AN, Sierra RJ. Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA. Orthopedics. 2014;37:e1124–1128. doi: 10.3928/01477447-20141124-90. [DOI] [PubMed] [Google Scholar]
  • 22.Philippot R, Adam P, Reckhaus M, Delangle F, Verdot F, Curvale G, Farizon F. Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res. 2009;95:407–413. doi: 10.1016/j.otsr.2009.04.016. [DOI] [PubMed] [Google Scholar]
  • 23.Philippot R, Boyer B, Farizon F. Intraprosthetic dislocation: a specific complication of the dual-mobility system. Clin Orthop Relat Res. 2013;471:965–970. doi: 10.1007/s11999-012-2639-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F. The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop. 2009;33:927–932. doi: 10.1007/s00264-008-0589-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Phillips CB, Barrett JA, Losina E, Mahomed NN, Lingard EA, Guadagnoli E, Baron JA, Harris WH, Poss R, Katz JN. Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement. J Bone Joint Surg Am. 2003;85:20–26. doi: 10.1302/0301-620X.85B3.13201. [DOI] [PubMed] [Google Scholar]
  • 26.Prudhon JL, Ferreira A, Verdier R. Dual mobility cup: dislocation rate and survivorship at ten years of follow-up. Int Orthop. 2013;37:2345–2350. doi: 10.1007/s00264-013-2067-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Sanchez-Sotelo J, Berry DJ. Epidemiology of instability after total hip replacement. Orthop Clin North Am. 2001;32:543–552, vii. [DOI] [PubMed]
  • 28.Singh JA. Epidemiology of knee and hip arthroplasty: a systematic review. Open Orthop J. 2011;5:80–85. doi: 10.2174/1874325001105010080. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Tian JL, Sun L, Hu RY, Tian XB. Cementless total hip arthroplasty with structural allograft for massive acetabular defect in hip revision. Chin J Traumatol. 2014;17:331–334. [PubMed] [Google Scholar]
  • 30.Williams JT, Jr, Ragland PS, Clarke S. Constrained components for the unstable hip following total hip arthroplasty: a literature review. Int Orthop. 2007;31:273–277. doi: 10.1007/s00264-006-0191-y. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Clinical Orthopaedics and Related Research are provided here courtesy of The Association of Bone and Joint Surgeons

RESOURCES