Abstract
Objective: This study explored the effects of different light curing modes and ethanol-wet bonding on dentin bonding strength and durability. Methods: A total of 54 molars were randomly divided into three groups: Single Bond 2, Gluma Comfort Bond, and N-Bond. Based on the three light-curing modes and presence or absence of ethanol pretreatment, the samples were assigned to six subgroups: high-light mode, ethanol pretreatment+high-light mode, soft-start mode, ethanol pretreatment+soft-start mode, standard mode, and ethanol pretreatment+standard mode. All samples were bonded with resin based on the experimental groups. After 24 h and 6 months of water storage, a universal testing machine was used to measure microtensile bond strength. Scanning electron microscopy (SEM) was applied to observe mixed layer morphology. Results: The 24-h and 6-month microtensile bond strengths of the ethanol pretreatment groups were significantly higher than those of the non-ethanol pretreatment groups at the same light modes (P<0.05). With or without ethanol pretreatment, the microtensile bond strengths of the high-light modes were significantly lower than those of the soft-start modes and standard modes (P<0.05). The microtensile bond strengths of samples from the 6-month water storage group significantly decreased compared with those of samples from the 24-h water storage group (P<0.05). The soft-start groups and standard groups formed better mixed layers than the high-light mode groups, whereas the ethanol pretreatment groups formed more uniform mixed layers than those without ethanol pretreatment. Conclusions: Ethanol-wet bonding technique, soft-start, and standard modes could improve dentin bonding properties.
Keywords: Light curing mode, Soft-start, Ethanol-wet bonding, Scanning electron microscopy (SEM), Bonding strength
1. Introduction
With continuing in-depth research on the adhesive properties and the increase in people’s aesthetic requirements, improving the quality and durability of the bonding interface has become an urgent problem in dentin bonding (Sadek et al., 2010; Guimarães et al., 2012; Li et al., 2012). Although the two-step total-etch technique can achieve high bond strength, there are problems of high technical sensitivity, uncontrollable interface moisture and poor durability. Since the dentin bonding strength is generated after the formation of micro-mechanical retention by the resin monomer in the etched collagen fiber network, the quality of the hybrid layer (Urapepon, 2014) is directly related to the strength and durability, and therefore a uniform and dense hybrid layer can obtain better bonding effect (Marshall et al., 2010). The moisture content and the cured extent of the adhesive resin on the dentin surface will affect the quality of the mixed layer, and further study of these factors will contribute to the ability to form a good hybrid layer, thus contributing to achieving an ideal bonding effect.
Introduced in the early 1990s, the water-wet bonding technique by Pashley et al. (2007) is a method of keeping dentin moist to prevent the collapse of the collagen fibers after etching, which will help the resin monomers penetrate the collagen fiber network. However, water-wet bonding has difficulty in controlling moisture and in standardization, and excessive moisture in the bonding interface often leads to hydrophobic resin monomers not completely penetrating, which results in the negative phenomenon of affecting dentin bonding properties such as incomplete polymerization, micro-phase separation, and nanoleakage (Tay and Pashley, 2003; Cunha et al., 2007). Therefore Pashley et al. (2007) proposed an ethanol-wet bonding technique where ethanol displacing water in dentin not only can reduce the moisture content of the dentin surface, but also can make it easier for adhesive resin to penetrate the dentin collagen fiber network, thereby facilitating the formation of a dense and homogeneous mixture of a hydrophobic layer to increase its bond strength and durability.
In addition, the resin binder is a highly flowable composite resin, and its main drawback is polymerization shrinkage during light curing (Osiewicz et al., 2015). If shrinkage stress during the polymerization process is greater than the adhesive force in the bonding interface, it will generate gaps in the bonding interface and the material inside. Thus, the polymerization shrinkage of a composite resin has a lot of negative effects on clinical applications, such as microleakage, edge color, fracture of teeth or restorative materials, post-operative sensitivity, and secondary caries (Bouschlicher et al., 2000; Marghalani, 2014). To facilitate clinical operation and shorten treatment time, high-powered light-emitting diode (LED) light units came into being. Although high intensity irradiation can improve the conversion of the resin monomer and enhance the mechanical properties of the material, the shrinkage stress and elastic modulus of the resin matrix are increased because of the shortening of the time to reach the gel point of the composite resin (Suh et al., 1999), which leads to reduced adhesion properties. Hardan et al. (2009) proposed the soft-start light curing mode where the initial light intensity has a lower irradiation, which can make the resin flow sufficiently to compensate for the volume shrinkage generated by the polymerization reaction, and then a high-light intensity is used in irradiation to improve the conversion rate of the resin monomer to a maximum extent (Malhotra and Kundabala, 2010). Thus light intensity and light curing modes that directly affect polymerization reaction and the degree of curing, also affect the resin monomer penetrating the dentin collagen fiber network in forming the mixed layer, thereby influencing the dentin bond performance.
In this study, the ethanol-wet bonding technique and light curing modes will apply to the fifth generation total-etch adhesive systems to explore their impact on dentin bonding strength and durability. There were three hypotheses as follows: (1) ethanol would not affect the performance of dentin bonding; (2) different light curing modes would not have different effects on dentin bonding properties; (3) the impacts of three adhesives on bonding properties would exhibit no difference.
2. Materials and methods
2.1. Grouping
A total of 54 third molars without caries were collected. Informed consent was obtained from the donors of the teeth and approved by the Ethics Committee of Jilin University (China). Under running water, a low-speed IsoMet saw (MTI Ltd., USA) was used to cut enamel from the occlusal surface of the molar to expose shallow dentin. To simulate the clinical dentin smear layer’s interface, the dentin surface was polished for 60 s using 600-grit SiC paper under running water. All samples were randomly divided into the following three groups based on different adhesives, namely, Single Bond 2 (3M ESPE Ltd., St. Paul, MN, USA), Gluma Comfort Bond (Heraeus Kulze Ltd., Hanau, Germany), and Tetric® N-Bond (Ivoclar Vivadent AG Ltd., Schaan, Liechtenstein).
Based on the three different light curing modes of Dr.’s Light Curing Light (Good Doctors Company, Korea) and with or without ethanol pretreatment, the samples were assigned to six subgroups: Group A, high-light mode; Group B, ethanol pretreatment+high-light mode; Group C, soft-start mode; Group D, ethanol pretreatment+soft-start mode; Group E, standard mode; Group F, ethanol pretreatment+standard mode. Light modes and exposure time are shown in Table 1.
Table 1.
Instructions for light mode
| Light mode | Time (s) | Profile |
| High-light | 10 | Continuous energy output power of 1000 mW/cm² for 10 s |
| Soft-start | 10 | Output power is raised gradually from 400 to 1200 mW/cm² in 5 s, and power remains at 1000 mW/cm² during the next 5 s |
| Standard | 20 | Continuous energy output power of 500 mW/cm² for 20 s |
Light intensity as is claimed by the manufacturer
2.2. Bonding procedure
The dentin surface was etched for 15 s by 37% (0.37 g/ml) phosphoric acid gel (Scientific Pharmaceuticals Inc., Pomona, CA, USA) and then rinsed for 30 s with distilled water. The cotton ball was placed on the edge of tooth to suck the excess water. An appropriate amount of adhesive was gently smeared on the moist dentin surface for 10 s using a small brush and lightly dried for 5 s. Subsequently, the adhesive surface was irradiated under different light curing modes according to the experimental groups. For the ethanol pretreatment groups, the etched dentin surface was inserted into 99.7% ethanol for 2 min, and excess ethanol was absorbed by a dry cotton ball. After the curing of adhesives, four layers of Z350 A2 resin (3M ESPE, USA) were stacked up to a height of 4 mm. Each layer was cured individually with the corresponding light mode for 20 s. After bonding, all samples were stored in distilled water at 37 °C for 24 h.
2.3. Measurement of specimens for microtensile bond strength
Under running water, a saw was used perpendicular to the bonding interface to cut the tooth with a cross-sectional area of 0.9 mm×0.9 mm. Cylindrical specimens of approximately 6.0 mm in length were obtained. “No-crack” specimens were randomly divided into two groups (n=10 each group). A group of samples was immediately used for the microtensile bond strength test, and the bonding interface area was measured and recorded with a Vernier caliper (0–150, Tricle Brand, Shanghai, China) with an accuracy of 0.01 mm. Another group of samples was stored in double distilled water at 37 °C for 6 months.
The microtensile fixture was placed on a universal testing machine (AG-Xplus 10KN, Shimadzu, Japan) with a pre-load of 5 N, a sensor of 500 N, and a crosshead speed of 1 mm/min until the specimens fractured. The microtensile bond strengths were calculated by the formula: σ s=F/(b×d), where σ s is the microtensile bond strength (MPa), F is the fracture tension (N), b is the sample width (mm), and d is the sample thickness (mm). The fracture type of the interfaces was observed by a stereomicroscope (SZX16, Olympus, Japan) at the magnification of 30×. The fracture types were divided into the following four types: (1) interfacial fracture occurring in the interface of dentin and resin; (2) cohesive fracture of dentin occurring within the dentin; (3) cohesive fracture of resin occurring within the resin; and (4) mixed fracture with interfacial fracture and cohesive fracture.
SPSS 17.0 (SPSS Inc., Chicago, IL, USA) was used for data analysis. Two-way analysis of variance (ANOVA) and multiple comparisons with Tukey’s test (5%) were used to analyze microtensile results. A Fisher test was performed to analyze the fracture type of the interfaces.
2.4. Observation of specimens using scanning electron microscopy
Following the aforementioned steps, 18 extracted teeth bonded with resin were prepared, and were cut into 4.0 mm×4.0 mm×1.5 mm. An intermediate portion of samples was etched by 37% phosphoric acid gel and then immersed in 5.25% sodium hypochlorite (Fuchen Chemical Reagent Factory, Tianjin, China) for 10 min. After the water rinse, samples were treated using 50.0%, 70.0%, 90.0%, and 99.7% ethanol for 15 min each, and soaked overnight in 99.7% ethanol. The hybrid layer was observed by field emission scanning electron microscopy (SEM; XL30, Japan) with an accelerating voltage of 10 kV.
3. Results
3.1. Microtensile results
Table 2 shows the results of 24-h microtensile bond strengths, and Table 3 shows the results of 6-month microtensile bond strengths. Under the same experimental conditions, the strengths of Single Bond 2 (SB), Gluma Comfort Bond (GB), and Tetric® N-Bond (NB) did not show a significant difference (P>0.05). The 24-h and 6-month microtensile bond strengths of the ethanol pretreatment groups were significantly higher (P<0.05) than those of the non-ethanol pretreatment groups with the same light modes. With or without ethanol pretreatment, the microtensile bond strengths of the high-light modes were significantly lower (P<0.05) than those of the soft-start and standard modes at 24 h and 6 months of water storage. The microtensile bond strengths of the standard modes and soft-start modes showed no statistical difference (P>0.05).
Table 2.
Mean microtensile bond strengths with standard division of 24 h groups (n=10)
| Adhesive | Mean microtensile bond strength (MPa) |
|||||
| High-light |
Soft-start |
Standard |
||||
| Null | Ethanol | Null | Ethanol | Null | Ethanol | |
| SB | 41.07±3.90Aa | 53.44±5.31Ab | 51.79±4.41Ab | 65.03±4.78Ac | 52.06±4.24Ab | 67.27±4.44Ac |
| GB | 37.88±3.35Aa | 50.03±3.59Ab | 49.15±3.91Ab | 62.80±4.32Ac | 49.19±3.78Ab | 63.75±4.33Ac |
| NB | 38.11±3.78Aa | 50.32±4.25Ab | 49.24±3.63Ab | 62.93±4.40Ac | 50.50±4.14Ab | 64.62±4.79Ac |
The same superscripted letters indicate no significant differences (P>0.05). a–c indicate statistically significant differences between different treatment methods (within the same adhesives). A–C indicate statistically significant differences between different adhesives (within the same treatment). SB: Single Bond 2; GB: Gluma Comfort Bond; NB: Tetric® N-Bond. The same for the following Table 3
Table 3.
Mean microtensile bond strengths with standard division of 6 months groups (n=10)
| Adhesive | Mean microtensile bond strength (MPa) |
|||||
| High-light |
Soft-start |
Standard |
||||
| Null | Ethanol | Null | Ethanol | Null | Ethanol | |
| SB | 18.07±3.05Aa | 32.07±3.41Ab | 31.28±3.52Ab | 49.49±4.34Ac | 32.06±3.15Ab | 51.09±4.22Ac |
| GB | 16.73±3.12Aa | 29.40±3.27Ab | 29.18±3.04Ab | 46.68±4.24Ac | 30.72±3.65Ab | 47.03±4.62Ac |
| NB | 17.97±2.99Aa | 30.70±3.41Ab | 29.65±3.52Ab | 46.92±3.72Ac | 30.85±3.48Ab | 48.85±4.59Ac |
Compared with 24 h, the microtensile bond strength in 6 months of each group was significantly decreased (P<0.05), but the decline in the microtensile bond strengths between the three adhesives showed no significant difference (P>0.05). The strengths of Groups A–F fell by an average of 54.89%, 40.07%, 40.00%, 25.00%, 38.29%, and 24.89%, respectively. Thus, the decline in the ethanol pretreatment groups was obviously lower than that in the non-ethanol pretreatment groups, and the decline in the soft-start modes and standard mode groups was far less than that in the high-light mode groups.
3.2. Fracture type observations
The fracture types of 24-h microtensile specimens are shown in Fig. 1. The fracture types of 6-month microtensile specimens are shown in Fig. 2. Fisher’s exact test showed that the fracture types of all groups were mainly interfacial fracture, and cohesive and mixed fractures were rare. We observed no significant differences among the groups (P>0.05).
Fig. 1.

Fracture types of 24-h microtensile specimens
A: high-light mode; B: ethanol pretreatment+high-light mode; C: soft-start mode; D: ethanol pretreatment+soft-start mode; E: standard mode; F: ethanol pretreatment+standard mode; SB: Single Bond 2; GB: Gluma Comfort Bond; NB: Tetric® N-Bond. The same for the following Figs. 2 and 3
Fig. 2.

Fracture types of 6-month microtensile specimens
3.3. Scanning electron microscopy
Fig. 3 shows that the high-light mode groups formed short and uneven resin tags and bubbly uneven mixed layers, whereas the soft-start groups and standard groups formed longer and more uniform resin tags and relatively continuous and uniform mixed layers. The ethanol pretreatment groups formed much longer and more uniform resin tags and more compact and uniform mixed layers than those without ethanol pretreatment. Resin tags and mixed layers formed by the three adhesives were similar.
Fig. 3.
SEM micrographs of Groups A–F
4. Discussion
In modern bonding technology, the dentin bonding interface frequently has incomplete polymerization, micro-phase separation and nanoleakage, which will adversely affect the performance of the dentin bonding (Cunha et al., 2007). Traditional water-wet bonding makes the collapsed collagen fiber network resume a fluffy state, but excess moisture in the bonding interface leads to phase separation and nanoleakage. However, the ethanol-wet bonding technique can solve this problem, since ethanol can replace the water in demineralized dentin, occupy gaps between collagen fibers, and reduce dentin hydrophilic, and most of the hydrophobic resin monomers can be soluble in alcohol, so they can better penetrate the dentin collagen fibers and dentinal tubules (Nishitani et al., 2006; Li et al., 2012; Sartori et al., 2015). In addition, ethanol in demineralized dentin can cause transverse shrinkage of collagen fibers that increases gaps between collagen fibers and decreases the collagen matrix hydrophilicity, which provides advantageous locations for subsequent infiltration of hydrophobic resin to form a homogeneous dense hybrid layer in order to obtain good bonding properties (Ahn et al., 2015; Yang et al., 2016).
Nishitani et al. (2006) suggested that the bonding strength of ethanol-wet bonding is higher than that of water-wet bonding. In our experiment, the 24-h and 6-month microtensile bond strengths of the ethanol pretreatment groups are significantly higher (P<0.05) than those of the non-ethanol pretreatment groups at the same light modes. With the same processing method, 6-month microtensile bond strength decreases significantly (P<0.05), indicating that the degradation of the bonding interface is inevitable in the water environment. The 6-month microtensile test not only shows bonding strength, but also reflects bonding durability. With the same light modes, the decline in microtensile bond strength of the ethanol pretreatment groups is significantly less than that of the non-ethanol pretreatment groups, indicating that ethanol-wet bonding technique will help to improve the durability of the bonding interface. SEM shows that ethanol groups can form more uniform and longer resin tags, and a more uniformly continuous hybrid layer than non-ethanol groups, which is consistent with the microtensile bond strength results, and the dentin bonding property is closely related to the quality of the hybrid layer and the number and length of resin tags. The results deny the first hypothesis, so ethanol-wet bonding technique can form a good dentin bonding interface, thereby significantly improving dentin bonding strength and durability of the total-etch adhesive.
Light curing intensity and pattern can influence the degree of curing of the resin binder, thus affecting its bonding properties (Haenel et al., 2015). Fahmy et al. (2009) reports that the pulse mode and fast mode have similar performance, so we chose high-light mode, soft-start mode, and normal-light mode instead of pulse mode in this experiment. To explore the effects of light modes on dentin bonding properties clearly, the irradiation time of the three modes is selected to be approximately of the same total light energy (Rueggeberg, 1998).
Light curing resin binder can incur a polymerization shrinkage reaction under the irradiation of certain wavelengths of visible light. This polymerization shrinkage will cause bonding internal stress increases that trigger microcracks in the bonding interface and materials, and these gaps may lead to microleakage and reduction in bond strength within the bonding interface (Giachetti et al., 2006). This is the main reason for the failure of repair materials (Mohammad et al., 2006). High-light intensity can improve the depth of curing and degree of conversion of the resin monomer to enhance mechanical properties of the composite resin (Nalcaci et al., 2005; Alto et al., 2006; Filho et al., 2008). Since curing speed is proportional to the square root of light intensity (Visvanathan et al., 2007), the curing speed of the high-light mode is faster and this can produce a larger polymerization shrinkage and internal stress within the bonding interface. It is not conducive to penetration and stretch of monomer into the dentin collagen fiber network, thus forming shorter resin tags and an asymmetrical mixed layer. In addition, it will make the oxygen inhibition layer thin on the adhesive surface (Kim et al., 2006) and make dentinal tubule fluid increasingly penetrate the adhesive surface (Breschi et al., 2008), thus affecting its bonding performance.
The soft-start mode is to start with a lower light intensity that extends the flow time of the resin to offset polymerization shrinkage stress, and then irradiate with a higher light intensity to fully cure the resin. Some scholars believe that the soft-start mode cannot reduce polymerization stress and microleakage, and that it has no significant effect on improving marginal adaptation in the bonding interface and degree of conversion of the resin monomer (Bouschlicher et al., 2000; Fleming et al., 2007). Too high or too low initial intensity cannot achieve a good curing effect (Marghalani, 2014), so the initial light intensity of the soft-start mode in our experiment is 400 mW/cm². Cunha et al. (2007) reported that the soft-start mode did not reduce the degree of conversion, but led to lower shrinkage stress and higher bond strength, which demonstrated the correlation with shrinkage stress and bond strength. When the adhesive surface is irradiated with a lower-intensity irradiation, phototropism shrinkage stress generated by the resin monomer is lower (Tseng et al., 2007). It is conducive to penetration and stretch of monomer into the dentin collagen fiber network to form longer and thicker resin tags and the dense and uniform mixed layer, and thus its microtensile bond strength will be higher. The experimental results show that with the same pretreatment, whether the water storage is 24 h or 6 months, the microtensile bond strength of the high-light model group is lower than those of the soft-start group and the standard mode group. The SEM shows that high-light mode groups formed short and uneven resin tags and bubbly uneven mixed layers, whereas the soft-start groups and standard groups formed longer and more uniform resin tags and relatively continuous and uniform mixed layers. It is consistent with the above views and denies the second assumption. So, different light curing modes have different effects on dentin bonding properties.
Microtensile results show that, in the same experimental conditions, the strengths of SB, GB, and NB groups at 24 h and 6 months water storage have no significant difference (P>0.05), and the declines of the microtensile bond strengths of three adhesives from 24 h to 6 months also show no significant difference. Microtensile bond strengths of different adhesives are different due to the different compositions and resin fillers. Single Bond 2 with the higher monomer concentration can form the thicker mixing layers after evaporation of solvents, and the component of polyalkenoic acid copolymer can enhance chemical combination with structures (Hashimoto et al., 2002). Silica nanofillers in Single Bond 2 can not only more easily penetrate the collagen fiber network, but also reduce volume shrinkage during polymerization, which can increase bond strength.
5. Conclusions
Dentin bonding performance is closely related to the quality of the mixed layers, and ethanol pretreatment can significantly improve the performance of total-etch dentin bonding systems and the quality of the mixed layer. Soft-start mode and standard mode can obtain better dentin bonding properties and quality of the mixed layer. The three total-etch adhesives have no significant difference on microtensile results or the quality of the mixed layers.
Footnotes
Project supported by the Science and Technology Research Project of the Education Department of Jilin Province of China (No. (2015)527)
Compliance with ethics guidelines: Mu-zi LI, Jin-rui WANG, Hong LIU, Xia WANG, Kang GAN, Xiu-ju LIU, De-li NIU, and Xiao-qing SONG declare that they have no conflict of interest.
All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2008 (5). Informed consent was obtained from all patients for being included in the study.
References
- 1.Ahn J, Jung KH, Son S, et al. Effect of additional etching and ethanol-wet bonding on the dentin bond strength of one-step self-etch adhesives. Restor Dent Endod. 2015;40(1):68–74. doi: 10.5395/rde.2015.40.1.68. (Available from: http://dx.doi.org/10.5395/rde.2015.40.1.68) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Alto M, Vieira R, Guimarães JGA, et al. Depth of cure of dental composites submitted to different light-curing modes. J Appl Oral Sci. 2006;14(2):71–76. doi: 10.1590/S1678-77572006000200002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Bouschlicher MR, Rueggeberg FA, Boyer DB. Effect of stepped light intensity on polymerization force and conversion in a photoactivated composite. J Esthet Dent. 2000;12(1):23–32. doi: 10.1111/j.1708-8240.2000.tb00195.x. (Available from: http://dx.doi.org/10.1111/j.1708-8240.2000.tb00195.x) [DOI] [PubMed] [Google Scholar]
- 4.Breschi L, Mazzoni A, Ruggeri A, et al. Dental adhesion review: aging and stability of the bonded interface. Dent Mater. 2008;24(1):90–101. doi: 10.1016/j.dental.2007.02.009. (Available from: http://dx.doi.org/10.1016/j.dental.2007.02.009) [DOI] [PubMed] [Google Scholar]
- 5.Cunha LG, Alonso RCB, Pfeifer CSC, et al. Modulated photoactivation methods: influence on contraction stress, degree of conversion and push-out bond strength of composite restoratives. J Dent. 2007;35(4):318–324. doi: 10.1016/j.jdent.2006.10.003. (Available from: http://dx.doi.org/10.1016/j.jdent.2006.10.003) [DOI] [PubMed] [Google Scholar]
- 6.Fahmy N, Naguib H, Guindy JE. Effect of light-emitting diode (LED) curing modes on resin/dentin bond strength. J Prosthodont. 2009;18(8):670–675. doi: 10.1111/j.1532-849X.2009.00502.x. (Available from: http://dx.doi.org/10.1111/j.1532-849X.2009.00502.x) [DOI] [PubMed] [Google Scholar]
- 7.Filho DN, Poskus LT, Guimarães JGA, et al. Degree of conversion and plasticization of dimethacrylate-based polymeric matrices: influence of light-curing mode. J Oral Sci. 2008;50(3):315–321. doi: 10.2334/josnusd.50.315. (Available from: http://dx.doi.org/10.2334/josnusd.50.315) [DOI] [PubMed] [Google Scholar]
- 8.Fleming GJP, Cara RR, Palin WM, et al. Cuspal movement and microleakage in premolar teeth restored with resin-based filling materials cured using a ‘soft-start’ polymerisation protocol. Dent Mater. 2007;23(5):637–643. doi: 10.1016/j.dental.2006.06.002. (Available from: http://dx.doi.org/10.1016/j.dental.2006.06.002) [DOI] [PubMed] [Google Scholar]
- 9.Giachetti L, Scaminaci Russo D, Bambi C, et al. A review of polymerization shrinkage stress: current techniques for posterior direct resin restorations. J Contemp Dent Pract. 2006;7(4):79–88. [PubMed] [Google Scholar]
- 10.Guimarães LA, Almeida JCF, Wang L, et al. Effectiveness of immediate bonding of etch-and-rinse adhesives to simplified ethanol-saturated dentin. Braz Oral Res. 2012;26(2):177–182. doi: 10.1590/s1806-83242012000200015. (Available from: http://dx.doi.org/10.1590/S1806-83242012000200015) [DOI] [PubMed] [Google Scholar]
- 11.Haenel T, Hausnerová B, Steinhaus J, et al. Effect of the irradiance distribution from light curing units on the local micro-hardness of the surface of dental resins. Dent Mater. 2015;31(2):93–104. doi: 10.1016/j.dental.2014.11.003. (Available from: http://dx.doi.org/10.1016/j.dental.2014.11.003) [DOI] [PubMed] [Google Scholar]
- 12.Hardan LS, Amm EW, Ghayad A, et al. Effect of different modes of light curing and resin composites on microleakage of Class II restorations–Part II. Odontostomatol Trop. 2009;32(126):29–37. [PubMed] [Google Scholar]
- 13.Hashimoto M, Ohno H, Kaga M, et al. Fractured surface characterization: wet versus dry bonding. Dent Mater. 2002;18(2):95–102. doi: 10.1016/s0109-5641(01)00023-9. (Available from: http://dx.doi.org/10.1016/S0109-5641(01)00023-9) [DOI] [PubMed] [Google Scholar]
- 14.Kim JS, Choi YH, Cho BH, et al. Effect of light-cure time of adhesive resin on the thickness of the oxygen-inhibited layer and the microtensile bond strength to dentin. J Biomed Mater Res B Appl Biomater. 2006;78(1):115–123. doi: 10.1002/jbm.b.30463. (Available from: http://dx.doi.org/10.1002/jbm.b.30463) [DOI] [PubMed] [Google Scholar]
- 15.Li F, Liu XY, Zhang L, et al. Ethanol-wet bonding technique may enhance the bonding performance of contemporary etch-and-rinse dental adhesives. J Adhes Dent. 2012;14(2):113–120. doi: 10.3290/j.jad.a21853. [DOI] [PubMed] [Google Scholar]
- 16.Malhotra N, Kundabala M. Light-curing considerations for resin-based composite materials: a review. Part I. Compend Contin Educ Dent. 2010;31(7):498–505. [PubMed] [Google Scholar]
- 17.Marghalani HY. The influence of different light-curing modes on microleakage of posterior resin composites. J Adhes Sci Technol. 2014;28(2):136–150. (Available from: http://dx.doi.org/10.1080/01694243.2013.827095) [Google Scholar]
- 18.Marshall SJ, Bayne SC, Baier R, et al. A review of adhesion science. Dent Mater. 2010;26(2):e11–e16. doi: 10.1016/j.dental.2009.11.157. (Available from: http://dx.doi.org/10.1016/j.dental.2009.11.157) [DOI] [PubMed] [Google Scholar]
- 19.Mohammad KA, Hamdoon MG, Rasheed ALM. Effects of curing modes of light emitting diode on shear bond strength of resin composite. Al-Rafidain Dent J. 2006;8(18):168–176. [Google Scholar]
- 20.Nalcaci A, Kucukesmen C, Uludag B. Effect of high-powered LED polymerization on the shear bond strength of a light-polymerized resin luting agent to ceramic and dentin. J Prosthet Dent. 2005;94(2):140–145. doi: 10.1016/j.prosdent.2005.05.001. (Available from: http://dx.doi.org/10.1016/j.prosdent.2005.05.001) [DOI] [PubMed] [Google Scholar]
- 21.Nishitani Y, Yoshiyama M, Donnelly AM, et al. Effects of resin hydrophilicity on dentin bond strength. J Dent Res. 2006;85(11):1016–1021. doi: 10.1177/154405910608501108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Osiewicz MA, Werner A, Pytko-Polonczyk J, et al. Contact- and contact-free wear between various resin composites. Dent Mater. 2015;31(2):134–140. doi: 10.1016/j.dental.2014.11.007. (Available from: http://dx.doi.org/10.1016/j.dental.2014.11.007) [DOI] [PubMed] [Google Scholar]
- 23.Pashley DH, Tay FR, Carvalho RM, et al. From dry bonding to water-wet bonding to ethanol-wet bonding. A review of the interactions between dentin matrix and solvated resins using a macromodel of the hybrid layer. Am J Dent. 2007;20(1):7–20. [PubMed] [Google Scholar]
- 24.Rueggeberg F. Contemporary issues in photocuring. Compend Contin Educ Dent Suppl. 1998;25:S4–S15. [PubMed] [Google Scholar]
- 25.Sadek FT, Braga RR, Muench A. Ethanol wet-bonding challenges current anti-degradation strategy. J Dent Res. 2010;89(12):1499–1504. doi: 10.1177/0022034510385240. (Available from: http://dx.doi.org/10.1177/0022034510385240) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Sartori N, Peruchi LD, Phark JH, et al. Permeation of intrinsic water into ethanol- and water-saturated, monomer-infiltrated dentin bond interfaces. Dent Mater. 2015;31(11):1385–1395. doi: 10.1016/j.dental.2015.08.159. (Available from: http://dx.doi.org/10.1016/j.dental.2015.08.159) [DOI] [PubMed] [Google Scholar]
- 27.Suh BI, Feng L, Wang Y, et al. The effect of the pulse-delay cure technique on residual strain in composites. Compend Contin Educ Dent. 1999;20(2):4–12. [PubMed] [Google Scholar]
- 28.Tay FR, Pashley DH. Have dentin adhesives become too hydrophilic? J Can Dent Assoc. 2003;69(11):726–731. [PubMed] [Google Scholar]
- 29.Tseng WY, Chen RS, Wang JL, et al. Effects on microstrain and conversion of flowable resin composite using different curing modes and units. J Biomed Mater Res B Appl Biomater. 2007;81(2):323–329. doi: 10.1002/jbm.b.30668. (Available from: http://dx.doi.org/10.1002/jbm.b.30668) [DOI] [PubMed] [Google Scholar]
- 30.Urapepon S. Degree of conversion of resin composite cured by light through a translucent fiber posts. J Adv Prosthodont. 2014;6(3):194–199. doi: 10.4047/jap.2014.6.3.194. (Available from: http://dx.doi.org/10.4047/jap.2014.6.3.194) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Visvanathan A, Ilie N, Hickel R, et al. The influence of curing times and light curing methods on the polymerization shrinkage stress of a shrinkage-optimized composite with hybrid-type prepolymer fillers. Dent Mater. 2007;23(7):777–784. doi: 10.1016/j.dental.2006.06.019. (Available from: http://dx.doi.org/10.1016/j.dental.2006.06.019) [DOI] [PubMed] [Google Scholar]
- 32.Yang H, Guo J, Deng D, et al. Effect of adjunctive application of epigallocatechin-3-gallate and ethanol–wet bonding on adhesive–dentin bonds. J Dent. 2016;44:44–49. doi: 10.1016/j.jdent.2015.12.001. (Available from: http://dx.doi.org/10.1016/j.jdent.2015.12.001) [DOI] [PubMed] [Google Scholar]