Abstract
We compared the performance of flocked and matched traditional rectal swabs collected from 236 children admitted with gastroenteritis in Botswana. All samples were tested using real time multiplex-PCR assays for nine enteric pathogens. There was a 20% higher detection of Shigella from flocked swabs, but most other pathogens had similar detection rates.
Enteric infections are the second leading cause of death in children under the age of 5 years (1). Botswana has experienced a number of diarrhoea outbreaks which have been associated with significant mortality (2). At outpatient clinic visits, children may not be able to produce stool in the short time interval between clinician assessment and return home; on inpatient wards, health-care providers are regularly in short supply, commonly have competing priorities, and so stool collections may not happen in a timely fashion. For these reasons, swabs have been used as an alternative to bulk stool samples (4). There is demonstrated superior performance of flocked swabs over traditional fibre wrapped swabs for respiratory as well as vaginal specimens (5,6). Flocked swabs have been used for the detection of respiratory viruses and bacteria (7). In a previous study, we found that specifically designed flocked rectal swabs resulted in higher detection of bacterial pathogens using multiplex PCR assays compared to bulk stool samples (8). For this study we compared the performance of flocked rectal swabs to traditional rectal swabs for the molecular detection of enteric pathogens in children with acute gastroenteritis in Botswana.
Two-hundred thirty-six children (109 females) aged ≤5 years presenting with diarrhoea at Princess Marina Hospital (PMH), Gaborone, Botswana were studied. Diarrhoea was defined according to World Health Organization criteria (9). Ethical approval was obtained from the Ministry of Health, PMH, University of Pennsylvania and McMaster University research ethics committees.
Paired flocked rectal swab and traditional rayon fibre swab (Copan Italia, Brescia, Italy) specimens were collected consecutively. The flocked swab was collected first and the swabs were transported chilled in a cooler box and stored at −80°C until testing. The swabs were pre-treated as previously described (8). Total nucleic acid extraction was performed according to the NucliSENS easy MAG instrument (bioMérieux, Marcy l’Étoile, France) Specific A protocol with final elution in 70uL.
Laboratory-developed real time multiplex PCR assays on the ABI 7500 FAST (Life Technologies) were used to detect the nine most prevalent gastrointestinal pathogens (rotavirus, norovirus GI/GII, adenovirus, Shigella, Salmonella, Campylobacter, ETEC LT/ST, Giardia and Cryptosporidium). Not all samples were tested for Campylobacter as the reagents for this target were not available for a portion of the study. The primers and probes areas previously described (8). Additional primers and probes for Giardia, Cryptosporidium, and ETEC LT/ST are shown in Table 1. Five microlitres of extracted nucleic acid from each swab was added to the primers, probes, and the QuantiTect multiplex no ROX PCR kit reagents for amplification of the bacterial and parasitic pathogens and QuantiTect Virus ROX Vial kit reagents for the viral pathogens (Qiagen, Mississauga, Ontario). Extraction and master-mix negative controls and a positive control were included with each assay. Cycling parameters for bacteria and parasite assays were: 1 min at 60°C, 15 min at 95°C, followed by 45 cycles of 20 sec at 95°C and 1 min 10 sec at 60°C, and a final hold of 1 min at 60°C. Cycling parameters for the viral assay were as follows: 1 min at 50°C, 20 min at 50°C, 5 min at 95°C, for reverse transcription and denaturation followed by 45 cycles of 15 sec at 95°C, 1 min 15 sec at 60°C), and a final 1 min hold at 60°C.
Table 1.
Pathogen target | Forward primer |
Reverse Primer |
Probe sequence | Target | Adapted from |
---|---|---|---|---|---|
Giardia | GACGGCT CAGGACA ACGGTT |
TTGCCAG CGGTGTC CG |
CCCGCGGCGG TCCCTGCTAG |
SSU RNA gene |
10 |
Cryptosporidium | CAAATTG ATACCGT TTGTCCT TCTG |
GGCATGT CGATTCT AATTCAG CT |
TGCCATACATT GTTGTCCTGAC AAATTGAA |
COWP gene |
11 |
E. coli ST | TTCACCT TTCGCTC AGGATG |
ACCCGGT ACAAGCA GGATTA |
CTGAAAGCAT GAATAGTAGC AATTACTG |
Stable toxin (ST) gene |
12 |
E. coli LT | AACAGGG AATATAG AGACCG |
CAACCTT GTGGTGC ATGATG |
AGAGGATGGT TACAGATTAG CAGGT |
Labile toxin (LT) gene |
13,14 |
Sensitivities were calculated using an expanded reference standard of either flocked swab or traditional swab positive (consensus standard), and the results were compared using the McNemar exact test for paired samples. Mean threshold cycle (Ct) values were calculated and mean differences (95% CI) for matching swabs determined. Samples were considered positive with a Ct value of less than 45. A paired sample t test was used to compare the Ct values in the matched positive/concordant samples. A p value < 0.05 was considered significant.
A total of 236 matched swab pairs were tested for Shigella spp., Salmonella spp and ETEC LT/ST; 189 matched swab pairs were tested for Campylobacter jejuni/coli; 210 matched swab pairs were tested for rotavirus, adenovirus and norovirus GI/GII; and 213 matched swab pairs were tested for Giardia and Cryptosporidium. The median age of the study participants that were sampled was 9.1 months (25–75% ile 4.5–13.9 months).
Sensitivities for flocked swabs across all pathogens ranged from 80%–96%, whereas for traditional swabs, sensitivities ranged from 70%–96%, Table 2. For viruses and parasites, no differences were observed between the two swabs, except for adenovirus, for which the detection rate was marginally higher in flocked compared to the traditional swab but the difference was not statistically significant, 96% vs 80%, p=0.070. For bacterial pathogens, the sensitivity for the flocked swab was significantly higher for Shigella spp compared to the traditional swab, 91% vs 70%, p=0.016. Overall, 25% of the samples were positive for Shigella using flocked swabs as compared to 19% using traditional swabs (yield difference 5.5%, 95% CI 1.0–10.0%). No statistically significant differences were observed for the other bacterial pathogens. Table 3 compares Ct values for reactive concordant samples. The mean Ct values for flocked swabs ranged from 23–34, whereas for traditional swabs they ranged from 22–35. When positive samples only were examined, detection of Shigella, Campylobacter, Salmonella, and Cryptosporidium occurred at statistically lower Ct using flocked swabs. Detection of rotavirus using flocked swabs occurred at a statistically higher Ct (p=0.002) compared to the traditional swabs, however the sensitivity for rotavirus using flocked swabs remained acceptable at 96.1%. There was no significant difference between Ct values for flocked and traditional swabs for the detection of norovirus GI/GII, ETEC LT/ST and Giardia detection. We also looked at the Ct trends of multiple pathogens within the same patient sample, and in 30 samples with Campylobacter and Shigella, 19/30 (63%) flocked swabs had lower Ct values for both pathogens compared to 3/30 (10%) for traditional swabs.
Table 2.
Pathogen target (number of paired samples tested) |
Result (number of samples for the pathogen) | Sensitivity of Flocked* |
Sensitivity of Traditional* |
McNemar exact test p-value |
||||
---|---|---|---|---|---|---|---|---|
Either positive |
Both positive |
Flocked swab only positive |
Traditional swab only positive |
Both negative |
||||
Viruses | ||||||||
Rotavirus (210) | 51 | 47 | 2 | 2 | 159 | 96.1 | 96.1 | 0.617 |
Adenovirus (210) |
46 | 35 | 9 | 2 | 164 | 95.7 | 80.4 | 0.070 |
Norovirus (210) | 22 | 19 | 2 | 1 | 188 | 95.5 | 90.9 | 1.000 |
All viruses | 119 | 101 | 13 | 5 | 511 | 95.8 | 89.1 | 0.099 |
Bacteria | ||||||||
Shigella (236) | 64 | 39 | 18 | 6 | 173 | 90.5 | 71.4 | 0.025 |
Campylobacter (189) |
121 | 85 | 23 | 16 | 65 | 87.1 | 81.4 | 0.34 |
Salmonella (236) |
24 | 17 | 4 | 2 | 213 | 91.3 | 82.6 | 0.69 |
ETEC LT/ST (236) |
54 | 39 | 4 | 11 | 182 | 79.6 | 92.6 | 0.121 |
All bacteria | 263 | 180 | 49 | 35 | 633 | 86.7 | 81.4 | 0.16 |
Parasites | ||||||||
Giardia (213) | 18 | 13 | 2 | 3 | 195 | 83.3 | 88.9 | 1.000 |
Cryptosporidium (213) |
39 | 33 | 4 | 2 | 174 | 94.9 | 89.7 | 0.683 |
All parasites | 57 | 46 | 6 | 5 | 369 | 91.2 | 89.5 | 1.000 |
Table 3.
Pathogen target | Mean Flocked Ct |
Mean Traditional Ct |
Mean difference of Ct values (95% CI) |
p value |
---|---|---|---|---|
Rotavirus | 23.39 | 22.29 | 1.10 (0.44 to 1.76) |
0.002 |
Adenovirus | 22.61 | 24.03 | −1.42 (−2.16 to −0.67) |
<0.001 |
Norovirus | 24.43 | 25.27 | −0.85 (−2.19 to 0.50) |
0.201 |
Shigella | 24.52 | 25.87 | −1.35 (−2.02 to −0.69) |
<0.001 |
Campylobacter | 33.18 | 34.26 | −1.08 (1.64 to −0.53) |
<0.001 |
Salmonella | 32.49 | 33.89 | −1.40 (−2.72 to −0.09) |
0.038 |
ETEC LT/ST | 29.69 | 29.44 | 0.25 (−1.09 to 1.58) |
0.708 |
Giardia | 34.47 | 35.01 | −0.54 (−1.96 to 0.88) |
0.424 |
Cryptosporidium | 32.75 | 34.11 | −1.36 (2.19 to −0.52 |
<0.001 |
Our findings suggest that the anatomically designed flocked rectal swabs provide a 20% increase in sensitivity for Shigella detection when compared with matched traditional swab samples. Given that Shigella is a common and treatable cause of severe diarrhoea in children and its detection has been associated with increased risk of mortality, our results have important ramifications for those seeking to optimize paediatric care in resource-limited settings (15–17).
The main limitation of our study is that the flocked swab samples were collected just prior to traditional swab samples and this may have potentially favoured the flocked swab samples. We had however collected 38 pairs of flocked rectal swab samples as part of our initial validation and PCR testing on both matched swabs revealed very close correlation for bacterial and viral targets and identical results for Shigella detection (10 positive and 28 negative, data not shown). Also given that for some pathogens (e.g. rotavirus) the mean nucleic acid yield was actually higher with the traditional swabs, this would suggest that sequence of sample collection did not always disadvantage the second swab. Several paired swab studies of other mucosal surfaces have shown that sequence of swab collection did not significantly affect sensitivity for pathogen detection (18, 19). One possible reason that the flocked rectal swab outperformed the traditional swab for Shigella detection is that it has a “stopper” at 3.2cm mark and this might aid in ensuring adequate sampling at the rectal mucosa (where Shigella causes pathology). Another possible reason is the “flocked” nature of the swab, which as mentioned has been shown to improve pathogen and cellular yield at other mucosal surfaces when compared with traditional swabs (5,20).
Overall, our findings suggest that these rectal flocked swabs may offer improved molecular detection of Shigella when compared with traditional swabs.
Highlights of the research.
Sensitivities for flocked swabs across all pathogens ranged from 80%–96%, whereas for traditional swabs, sensitivities ranged from 70%–96%
Our findings suggest that the anatomically designed flocked rectal swabs provide a 20% increase in sensitivity for Shigella detection when compared with matched traditional swab samples
Our results have important ramifications for those seeking to optimize pediatric care in resource-limited settings
Acknowledgments
Funds for this project were received from Grand Challenges Canada (grant 0009-02-01-01-02). This publication was made possible through core services and support from the Penn Center for AIDS Research, an NIH-funded program (P30 AI 045008). We thank Copan Italia SpA for providing the swabs.
Footnotes
Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Conflict of Interest
The authors have nothing to disclose and declare no potential conflict of interest.
References
- 1.Walker CL, Rudan I, Liu L, Nair H, Theodoratou E, Bhutta ZA, O'Brien KL, Campbell H, Black RE. Global burden of childhood pneumonia and diarrhoea. Lancet. 2013;381:1405–1416. doi: 10.1016/S0140-6736(13)60222-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Creek TL, Kim A, Lu L, Bowen A, Masunge J, Arvelo W, Smit M, Mach O, Legwaila K, Motswere C, Zaks L, Finkbeiner T, Povenelli L, Maruping M, Ngwaru G, Tebele G, Bopp C, Puhr N, Johnston SP, Dasilva AJ, Bern C, Beard RS, Davis MK. Hospitalisation and mortality among primarily non-breastfed children during a large outbreak of diarrhoea and malnutrition in Botswana, 2006. J Acquir Immune Defic Syndr. 2010;53:14–19. doi: 10.1097/QAI.0b013e3181bdf676. [DOI] [PubMed] [Google Scholar]
- 3.Harry KH, Turner JC, Madhusudhan KT. Comparison of physical characteristics and collection and elution performance of clinical swabs. Afr J Microbiol Res. 2013;7:4039–4048. [Google Scholar]
- 4.Kabayiza JC, Andersson ME, Welinder-Olsson C, Bergström T, Muhirwa G, Lindh M. Comparison of rectal swabs and faeces for real-time PCR detection of enteric agents in Rwandan children with gastroenteritis. BMC Infect Dis. 2013;13:447. doi: 10.1186/1471-2334-13-447. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Daley P, Castriciano S, Chernesky M, Smieja M. Comparison of flocked and rayon swabs for collection of respiratory epithelial cells from uninfected volunteers and symptomatic patients. J Clin Microbiol. 2006;44:2265–2267. doi: 10.1128/JCM.02055-05. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Benschop CCG, Wiebosch DC, Kloosterman AD, Sijen T. Post-coital vaginal sampling with nylon flocked swabs improves DNA typing. Forensic Sci Int Genet. 2010;4:115–121. doi: 10.1016/j.fsigen.2009.07.003. [DOI] [PubMed] [Google Scholar]
- 7.Dube FS, Kaba M, Whittaker E, Zar HE, Nicol MP. Detection of Streptococcus pneumoniae from different types of nasopharyngeal swabs in children. Plos ONE. 2013;8:e68097. doi: 10.1371/journal.pone.0068097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Goldfarb DM, Steenhoff AP, Pernica JM, Chong S, Luinstra K, Mokomane M, Mazhani L, Quaye I, Goercke I, Mahony J, Smieja M. Evaluation of anatomically designed flocked rectal swabs for molecular detection of enteric pathogens in children admitted to hospital with severe gastroenteritis in Botswana. J Clin Microbiol. 2014;52:3922–3927. doi: 10.1128/JCM.01894-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.WHO. Geneva: 2008. Manual of rotavirus detection and characterization methods. [Google Scholar]
- 10.Verweij JJ, Blange RA, Templeton K, Schinkel J, Brienen EA, van Rooyen MAA, van Lieshout L, Polderman AM. Simultaneous detection of Entamoeba histolytica, Giardia lamblia, and Cryptosporidium parvum in fecal samples by using multiplex real-time PCR. J Clin Microbiol. 2004;42:1220–1223. doi: 10.1128/JCM.42.3.1220-1223.2004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Guy RA, Payment P, Krull UJ, Horgen PA. Real-time PCR for quantification of Giardia and Cryptosporidium in environmental water samples and sewage. Appl Environ Microbiol. 2003;69:5178–5185. doi: 10.1128/AEM.69.9.5178-5185.2003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Lothigius A, Janzon A, Begum Y, Sjöling A, Qadri F, Svennerholm AM, Bölin I. Enterotoxigenic Escherichia coli is detectable in water samples from an endemic area by real-time PCR. J Appl Microbiol. 2008;104:1128–1136. doi: 10.1111/j.1365-2672.2007.03628.x. [DOI] [PubMed] [Google Scholar]
- 13.Stacy-Phipps S, Mecca JJ, Weiss JB. Multiplex PCR assay and simple preparation method for stool specimens detect enterotoxigenic Escherichia coli DNA during course of infection. J Clin Microbiol. 1995;33:1054–1059. doi: 10.1128/jcm.33.5.1054-1059.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Hidaka A, Hokyo T, Arikawa K, Fujihara S, Ogasawara J, Hase A, Hara-Kudo Y, Nishikawa Y. Multiplex real-time PCR for exhaustive detection of diarrhoeagenic Escherichia coli. J Appl Microbiol. 2009;106:410–420. doi: 10.1111/j.1365-2672.2008.04043.x. [DOI] [PubMed] [Google Scholar]
- 15.Kotloff KL, Winickoff JP, Ivanoff B, Clemens JD, Swerdlow DL, Sansonetti PJ, Adak GK, Levine MM. Global burden of Shigella infections: implications for vaccine development and implementation of control strategies. Bull World Health Organ. 1999;77:651–666. [PMC free article] [PubMed] [Google Scholar]
- 16.Pernica JM, Steenhoff AP, Welch H, Mokomane M, Quaye I, Arscott-Mills T, Mazhani L, Lechiile K, Mahony J, Smieja M, Goldfarb DM. Correlation of clinical outcomes with multiplex molecular testing of stool from children admitted to hospital with gastroenteritis in Botswana. J Pediatric Infect Dis Soc. 2015:1–7. doi: 10.1093/jpids/piv028. 1–7, [Epub ahead of print] [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.O'Reilly CE, Jaron P, Ochieng B, Nyaguara A, Tate JE, Parsons MB, Bopp CA, Williams KA, Vinjé J, Blanton E, Wannemuehler KA, Vulule J, Laserson KF, Breiman RF, Feikin DR, Widdowson MA, Mintz E. Risk factors for death among children less than 5 years old hospitalized with diarrhea in rural western Kenya, 2005–2007: a cohort study. PLoS Med. 2012;9:e1001256. doi: 10.1371/journal.pmed.1001256. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.De Silva S, Wood G, Quek T, Parrott C, Bennett CM. Comparison of Flocked and rayon swabs for detection of nasal carriage of Staphylococcus aureus among pathology staff members. J Clin Microbiol. 2010;48:2963–2964. doi: 10.1128/JCM.01617-09. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Coorevits L, Vanscheeuwijck C, Traen A, Bingé L, Ryckaert I, Padalko E. Evaluation of Copan FLOQSwab for the molecular detection of Chlamydia trachomatis by Abbott RealTime CT PCR. Acta Clin Belg. 2015 doi: 10.1179/2295333715Y.0000000036. [Epub ahead of print] [DOI] [PubMed] [Google Scholar]
- 20.Esposito S, Molteni G, Daleno C, Valzano A, Cesati L, Gualtieri L, Tagliabue C, Bosis S, Principi N. Comparison of nasopharyngeal nylon flocked swabs with universal transport medium and rayon-bud swabs with a sponge reservoir of viral transport medium in the diagnosis of paediatric influenza. J Med Microbiol. 2010;59:96–99. doi: 10.1099/jmm.0.015305-0. [DOI] [PubMed] [Google Scholar]