A pictorial guide for the second trimester ultrasound

Michael Bethune 1,2,, Ekaterina Alibrahim 1, Braidy Davies 1, Eric Yong 1
PMCID: PMC5029995  PMID: 28191183

Abstract

Introduction: The second trimester ultrasound remains an important screening tool for detecting fetal abnormalities. This pictorial guide for the second trimester ultrasound is designed to assist practitioners to produce a high quality diagnostic survey of the fetus by demonstrating and describing recommended images.

Methods: Each image is discussed in detail and has an associated drawn line diagram to aid in the identification of the important features of that image. There is a description of the salient landmarks and relevant measurements.

Result: The authors hope this article may act as a useful guide to all practitioners performing second trimester ultrasounds.

Keywords: imaging, prenatal ultrasound, second trimester routine ultrasound

Introduction

The second trimester ultrasound is commonly performed between 18 and 22 weeks gestation. Historically the second trimester ultrasound was often the only routine scan offered in a pregnancy and so was expected to provide information about gestational age (correcting menstrual dates if necessary), fetal number and type of multiple pregnancy, placental position and pathology, as well as detecting fetal abnormalities. 1 Many patients now have several ultrasounds in their pregnancy with the first trimester nuchal translucency assessment becoming particularly common. 2 The second trimester ultrasound is now less often required for dating or detection of multiple pregnancies but remains very important to detect placental pathology and, despite advances in first trimester anomaly detection, remains an important ultrasound for the detection of fetal abnormalities. In order to maximise detection rates there is evidence that the ultrasound should be performed by operators with specific training in the detection of fetal abnormalities. 3

Second trimester ultrasound landmarks

This pictorial guide is provided as, despite a large volume of literature on the subject, it is difficult to find a single publication that describes the landmarks and range of images which are most useful to look for when performing the second trimester ultrasound. These images were all obtained on GE Healthcare Voluson E8 or 730 machines (GE Healthcare, Sydney, Australia). The images provided are representative. Some examinations may yield significantly better images while other examinations, especially in large patients, may yield much less clear images. The authors are not suggesting that an examination is only complete if all of these images are presented. Rather, we are suggesting that each labelled landmark is worth examining carefully during a second trimester ultrasound. Although the important features are described it is beyond the scope of this article to discuss the associated pathologies of each feature.

This guide is presented roughly in cephalic to caudal order, but where possible grouped by organ system. Operators would benefit from a systematic approach to ensure that all structures are seen even in difficult circumstances, as it can be possible to miss a structure, especially when there are active fetal movements.

Recording the ultrasound

It is useful to have some record of the examination for future reference. Video clips or DVD recording of the scan has the advantage of providing moving images, which is particularly helpful when assessing the fetal heart. A series of still images is however easier to store and refer to in the future. Images should clearly display identifying information such as the patient's full name; birth date; medical record or identification number; date of the ultrasound examination; and site where the examination was performed (hospital or private practice), 4 ensuring compliance with local legal requirements.

Biometry

There are a number of measurements to take during the examination. Some measurements of fetal size should be included in the formal report of each examination. The minimum measurements to report are: biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL). 5 7 Other biometry which could be reported include: humerus length (HL), nasal bone length (NB), nuchal fold (NF), cerebellar diameter (TCD), cisterna magna and cervical length. A combination of BPD and HC measurements can be used to calculate an estimated date of delivery (EDD). 8

General scanning principles

Many machine pre‐sets are a compromise of resolution and persistence and it is important to have a high resolution pre‐set available. A separate pre‐set with higher frame rates and higher contrast is useful for cardiac images. When taking images the structure of interest should occupy about 75% of the screen to maximise resolution. Write zoom (pre‐acquisition) is the zoom mode of choice as it has higher resolution than read zoom (post acquisition).

Because of the risk of artefacts it is often useful to visualise the major structures in at least two planes. The measurement techniques recommended here are widely accepted techniques, however some charts may use different techniques and each operator should measure in accordance with the charts agreed within their own work place and population.

Amniotic fluid assessment is usually subjective 9 but maximum vertical pocket or amniotic fluid Index (AFI) can be used if there is concern about excess or insufficient amniotic fluid.

Fetal movements should be observed and commented upon. It is essential to see flexion or extension of a limb at least once during the scanning process to reduce the chance of missing a case of arthrogryposis. 10 Similarly the opening of the hands to exclude clenched fingers is important to rule out several syndromes. 11

The fetal head

The standard axial fetal brain planes include the biparietal diameter, the transventricular plane and the cerebellar plane (Figures 13). Many of the fetal measurements are taken from these planes including the BPD and HC. Measurements of the Cerebellum, Cisterna Magna and Nuchal fold can be useful. Further images of the head which may add value include the mid sagittal plane to view mid line brain structures, coronal cerebellum and coronal face (Figures 46).

Figure 1.

Figure 1

Biparietal diameter plane.
  • 1
    Biparietal diameter
  • 2
    Cavum Septum pellucidum
  • 3
    Thalami
  • 4
    Hypoechoic skull sutures
  • 5
    Third Ventricle
  • 6
    Choroid
  • 7
    Posterior Lateral ventricle
  • 8
    Corpus callosum

Figure 3.

Figure 3

Cavum septum pellucidum.

The corpus callosum is visible as a hypoechoic region just anterior to the CSP.

Figure 4.

Figure 4

Cerebellar plane.
  • 1
    Cavum Septum Pellucidum
  • 2
    Cerebellar lobes
  • 3
    Cerebellar vermis
  • 4
    Cisterna Magna
  • 5
    Nuchal Fold
  • 6
    Cerebral peduncles
  • 7
    Falx
  • 8
    Thalami

Figure 6.

Figure 6

Coronal cerebellum.
  • 1
    Cerebellar lobe
  • 2
    Cerebellar vermis
  • 3
    Falx
  • 4
    Posterior horn of lateral ventricle
  • 5
    Cisterna magna

Figure 1: Biparietal diameter plane

This is a cross section of the fetal head obtained at the level of the thalami. The cerebellum, orbits and ears should not be visualised in this scanning plane. The falx should be positioned horizontal and equidistant from both parietal bones to avoid acynclitism (head tilted to one side). The operator should look for a symmetrical appearance to both hemispheres. The continuous midline echo representing the falx is broken in the anterior third by the cavum septum pellucidum (CSP). Behind this in the middle of the falx a thin slit representing the third ventricle is often visible.

The BPD measurement is obtained from outer skull bone to inner skull bone (leading edge to leading edge), perpendicular to the falx at the maximum diameter. 12 The HC is measured as an ellipse around the outside of the skull bones. Both of these measurements can be used to confirm gestational age. A head circumference measuring less than 3 standard deviations from the mean may indicate microcephaly. 13

Slight gaps in the echogenic skull bone outline are evident and represent the skull sutures. There should be a normal oval skull shape with no depression of the petrous temporal bones and no angulation near the sutures. The normal bone density of the skull should be more echogenic than the falx.

Figure 2: Transventricular plane

Figure 2.

Figure 2

Transventricular plane.

The lower right images demonstrate that angling the fetal head can improve visualisation of the near field lateral ventricle.
  • 1
    Near field posterior horn of lateral ventricle
  • 2
    Choroid
  • 3
    Far field posterior horn of lateral ventricle
  • 4
    Cavum Septum Pellucidum (CSP)
  • 5
    Corpus callosum (CC)

This image is a cross‐section of the head just above the BPD‐ plane, at the level of the atrium of the lateral ventricles but still with the CSP in view. The image usually demonstrates a substantial length of choroid plexus superior to the level of the thalami.

The lateral ventricular measurement can be taken from inner wall to inner wall at the level of the glomus of the choroid plexus. The lateral ventricle should be measured at right angles to the falx. 12 Over the gestational range 15 to 40 weeks 10 mm or larger is considered abnormal. 14

It may be advantageous to measure the near field ventricle as well as the far field lateral ventricle. Angling the probe to place the falx at ~15° to horizontal may facilitate visualisation of the near field ventricle.

Figure 3: Cavum septum pellucidum

It is beneficial to look carefully at the CSP to ensure it is distinguished from the third ventricle and to identify the corpus callosum. Just anterior to the CSP there is often a fine hypoechoic ‘U’ shaped structure representing the anterior leaflets of the corpus callosum. The CSP is an important landmark for development of the corpus callosum, if it is not visualised then there is a risk of a range of brain abnormalities. 15

Figure 4: Cerebellar plane

This plane is inferior to the BPD plane with the probe tilted backward into the posterior fossa. The plane is correct when one can visualise the thalami and cavum septum pellucidum in the same plane as the cerebellum. 12

The cerebellum is a dumbbell shaped structure, with symmetrical lobes. The central vermis is slightly more echogenic than the lateral lobes.

The trans‐cerebellar diameter is the widest measurement across the cerebellum, perpendicular to the falx. Cerebellar size in millimetres correlates with gestational age up to 20 weeks and is larger than gestational age after this time. A cerebellum measuring 2 mm less than gestational age is a concerning finding. 16

The cisterna magna can be measured from the posterior margin of the cerebellar vermis to the inside of occipital bone in the midline (following an imaginary continuation of the falx). A measurement of 2–10 mm is normal in the second and third trimesters. 17

The nuchal fold is a measurement taken from outer skin line to outer bone in the midline (following an imaginary continuation of the falx). Less than 6 mm is considered normal up to 22 weeks.

When measuring the nuchal fold angling the probe to place the falx at ~15° to horizontal may provide a sharper image of skin line and bone. This may minimise the chance of beam width artefact causing a thickened nuchal fold measurement.

Figure 5: Corpus callosum

Figure 5.

Figure 5

Corpus callosum.
  • 1
    Corpus callosum
  • 2
    Cavum Septum Pellucidum
  • 3
    Nasal bone

This is a mid‐sagittal image through the fetal head. A mid sagittal plane can often visualise most of the length of the corpus callosum. Visualisation of the corpus callosum can be facilitated by trying to angle the probe so as to scan through the area of the anterior fontanelle. The corpus callosum connects the left and right lobes of the brain. It sits superior to the cavum septum pellucidum and extends backwards as a hypoechoic line. The presence of the corpus callosum can be confirmed with color Doppler of the pericallosal artery. 18

Figure 6: Coronal cerebellum

This is a coronal image through the back of the fetal head. This image may be useful to demonstrate normal depth of the cerebellar vermis. The cerebellar lobes should be equal size. The vermis of the cerebellum should be more than 1/2 the height of the lobes. 19

The fetal face

The facial structures can be examined both coronally and axially. The orbits, nose and mouth need to be separately visualised (Figures 711). Areas which warrant particular attention are the size and spacing of the eyes as well as the upper lip (which is best imaged in two planes). There are a number of ultrasound techniques which have been suggested to improve detection of facial abnormalities including measurement of facial angles and 3D ultrasound techniques, 20 , 21 these techniques are usually employed when there is a suspicion of an abnormality rather than in the routine setting and are beyond the scope of this paper. Shortening (hypoplasia) of the nasal bone has been associated with Down syndrome 22 (Figure 12).

Figure 7.

Figure 7

Coronal Orbits.
  • 1
    Orbit
  • 2
    Lens of the eye
  • 3
    Nasal bridge

Figure 11.

Figure 11

Lower lip and mandible.
  • 1
    Lower lip
  • 2
    Mandible

Figure 12.

Figure 12

Profile and nasal bone
  • 1
    Nasal bone
  • 2
    Nose
  • 3
    Mandible
  • 4
    Hard palate.

Figure 7: Coronal orbits

This is a coronal image of the back of the face, through the orbits. The orbits should be equal size with the gap between each orbit approximately the same as the width of each orbit (dividing the face into thirds). The lenses can be seen as central circles that should not have internal echogenicity. Lens opacity may indicate congenital cataracts.

Figure 8: Coronal lips and nose

Figure 8.

Figure 8

Coronal lips and nose
  • 1
    Two nostrils
  • 2
    Upper lip
  • 3
    Lower lip
  • 4
    Chin

This image is obtained by moving the scanner forward from the coronal orbital view to the very front of the face. This image demonstrates two nostrils and a separate intact upper lip. Being able to visualise the tip of all four structures (the nose, upper lip, lower lip, and chin) in the same coronal image makes micrognathia an unlikely finding.

Figure 9: Axial orbit and lenses

Figure 9.

Figure 9

Axial orbit and lenses.
  • 1
    Orbit
  • 2
    Lens
  • 3
    Nasal bridge

This is a transverse section of the fetal face though the orbits. The face needs to be looking up for best views. The orbits should be approximately equal size and should be evenly spaced. The width of the nasal bridge between each orbit is approximately the same as the size of each orbit – dividing the face into thirds.

Figure 10: Upper lip and palate

Figure 10.

Figure 10

Upper lip and palate.
  • 1
    Upper lip
  • 2
    Hard palate.

This is a transverse image used to obtain a cross section through the upper lip and hard palate. It demonstrates an intact skin line of the upper lip (no cleft). Behind this is an echogenic intact hard palate; this confirms the correct plane, and is useful to distinguish palate involvement if a cleft lip is present. The hard palate has internal areas of reduced echogenicity representing tooth sockets. This image does not exclude cleft of the soft palate or secondary hard palate.

Figure 11: Lower lip and mandible

This is a transverse image obtaining a cross section through the lower lip and jaw. The image demonstrates an intact lower jaw line. The width of the mandible should be similar to the width of the maxilla and may be reduced in micrognathia. Again tooth sockets are apparent.

Figure 12: Profile and nasal bone

This is a mid‐sagittal image best taken with the angle of the face at about 45°. 22 The skin line over the nose should be close to horizontal. This is a slightly more laid back angle than the corpus callosum view. A slight gap between the nasal bone and the frontal bone should be visualised to help identify the extent of the nasal bone.

The full length of the echogenic calcified nasal bone can be measured. The 2.5th centile for the nasal bone measurement has been reported as 4.4 mm at 18 weeks and 5 mm at 20 weeks. 23 Other authors have used the 0.75th multiples of the median (MoM) being 3.6 mm at 18 weeks and 4 mm at 20 weeks. 24 A hypoplastic nasal bone has been associated with an increased risk of Down Syndrome. 25

There should be no frontal bossing – no forward sloping of the forehead. The tip of the nose, upper lip, lower lip, and chin should line up along the same imaginary line. If the chin is significantly behind this imaginary line then micrognathia is suspected. 26

The fetal chest and heart

It is important to establish situs. Both the heart and stomach should be seen to be on the left side of the fetus. Establishing situs can be confusing, especially for learning practitioners due to variable fetal positions.

One method to confirm visceral situs (sometimes referred to as the Cordes technique) has been demonstrated to be useful in normal and abnormal situations. 27 The technique is to orientate the fetal head to the right side of the ultrasound screen with the fetus lying horizontally across the screen. From this starting position, rotate the transducer 90° clockwise to obtain a transverse image of the fetus through the fetal heart. If the left hand of the operator is placed in front of the ultrasound screen positioned as an ‘L’ shape with the tips of fingers pointing towards the fetal sternum and the palm placed on the fetal spine, the thumb will now be pointing towards the left side of the fetus.28

Both hemidiaphragms can be visualised sagittally (Figures 14 and 15). The lung fields should be carefully inspected for cystic or echogenic areas.

Figure 14.

Figure 14

Diaphragm and lungs.
  • 1
    Stomach
  • 2
    Diaphragm
  • 3
    Heart
  • 4
    Lungs

Figure 15.

Figure 15

Coronal situs.
  • 1
    Stomach
  • 2
    Heart
  • 3
    Scapula
  • 4
    Diaphragm
  • 5
    Iliac crest

Figure 13.

Figure 13

Cordes Technique. The operator places his left hand in front of the screen with the palm on the spine and the fingers pointing at the sternum – the thumb of his left hand now points to the left side of the fetus.

The heart is a difficult organ to assess due to the size, rapid movements and large number of small parts. It is unfortunately also a common site for abnormalities. This is an area of the examination which is best done in real time or saved as a video clip. As well as the internal cardiac structures the examiner must be sure that the heart is correctly positioned on the left side of the chest, with the interventricular septum at about a 45° angle and is of normal size.

The axial images presented here are based on the five short axis views 29 (Figures 1724). These views can also be assessed with color and/or power Doppler. Sagittal views of the chest can be also used to show the fetal arterial vessels (Figures 2528). The heart rate should be noted throughout the scanning time to look for arrhythmias and can be recorded (Figure 29). Extra views of the systemic venous return to the right atrium can be readily obtained (Figure 30).

Figure 17.

Figure 17

Four chamber view of heart.
  • 1
    Right ventricle (RV)
  • 2
    Moderator band
  • 3
    Left ventricle (LV)
  • 4
    Left atrium (LA)
  • 5
    Foramen ovale
  • 6
    Descending aorta
  • 7
    Ribs
  • 8
    Pulmonary veins
  • 9
    Right atrium (RA)

Figure 24.

Figure 24

Three vessels and trachea view (3VT), Doppler assessment. The correct direction of flow (away from the heart) is demonstrated in both the aorta and ductus Arteriosus.

Figure 25.

Figure 25

Aortic arch.
  • 1
    Aortic arch
  • 2
    Three head and neck vessels arise from the aorta
  • 3
    Descending aorta
  • 4
    Spine
  • 5
    Heart

Figure 28.

Figure 28

Ductal arch, Doppler assessment.

Demonstrates flow away from the heart with no obvious turbulence or reverse flow and no tributaries directed towards the neck.

Figure 29.

Figure 29

Fetal heart rate.

Figure 30.

Figure 30

SVC & IVC.
  • 1
    Superior vena cava
  • 2
    Right atrium
  • 3
    Inferior vena cava
  • 4
    Diaphragm
  • 5
    Spine

Figure 18.

Figure 18

Four‐chamber with blood flow – intraventricular septum. Color flow is seen into both ventricles, all of the way to the apex. Flow is demonstrated across the foramen ovale.

Figure 20.

Figure 20

LVOT Doppler assessment. Forward flow is seen across the aortic valve with no obvious turbulence.

Figure 22.

Figure 22

RVOT Doppler assessment. No turbulence is seen across the pulmonary valve, the direction of flow down the ductus arteriosus is correct.

Figure 26.

Figure 26

Aortic arch, Doppler assessment.

Figure 14: Diaphragm and lungs

This sagittal image demonstrates intact diaphragms on each side especially posteriorly near the spine, a common site for diaphragmatic defects. The stomach is visible beneath and heart above the diaphragm. It is also beneficial to identify homogeneous appearing lung fields to attempt to exclude echogenic or cystic lung lesions.

Figure 15: Coronal situs

This is a coronal section through the thorax and abdomen. The heart and stomach are observed to be both left sided with the diaphragm as an intact line between.

Figure 16: Abdominal situs

Figure 16.

Figure 16

Abdominal situs.
  • 1
    Stomach
  • 2
    Aorta
  • 3
    IVC
  • 4
    Spine

This image is a transverse section through the upper abdomen just below the four‐chamber view of the heart. It is the same section or just above the level of the abdominal circumference. The stomach is a left sided cystic structure that should not cross the mid line to the right side.

The aorta sits just in front of the spine, slightly to the left of the spine. The inferior vena cava (IVC) is anterior to the aorta and right sided.

Figure 17 and 18: Four chamber view

This is an axial view through the lower part of the fetal chest. The best B‐mode images are obtained with the apex orientated superiorly. Obtaining a full length of a rib on each side is a good technique to avoid an oblique section.

There are a large number of features to demonstrate in this image, each should be separately considered.

  • 1

    Size of the heart should be ~1/3 the size of the thorax.

  • 2

    Axis of the interventricular septum is ~45° pointing to the left.

  • 3

    Left and right sides of the heart should be approximately equal size. Both left and right ventricles should extend to the apex of the heart and should be approximately equal in width at the level of the atrio‐ventricular (AV) valves.

  • 4

    The crux of the heart demonstrates an offset cross arrangement of the AV valves. The right valve (tricuspid) is closer to apex than the left (mitral).

  • 5

    Normal valve opening and closing with no focal valve echogenicities or thickening.

  • 6

    The right ventricle has the moderator band at the apex, closest to the sternum.

  • 7

    The left atrium has pulmonary veins entering it.

  • 8

    The foramen ovale leaflet is visible moving in the left atrium, no more than half way into the atrial cavity.

  • 9

    There is a single vessel (descending aorta) behind heart just to the left of the midline (as defined by the ossification centre of the spinal body).

  • 10

    There is occasionally some fluid in the pericardial sac where a thin rim is likely to be physiological (up to 2 mm). 30 Color Doppler is best performed with the septum between 45° and horizontal. This allows for improved Doppler detection of flow.

Doppler settings need to be sufficient to demonstrate the physiological atrial septal defect of the foramen ovale and complete filling of the ventricles. 31

Figures 19 and 20: Left ventricular outflow tract (LVOT)

Figure 19.

Figure 19

Left ventricular outflow tract.
  • 1
    Right ventricle
  • 2
    Left ventricle
  • 3
    Rib
  • 4
    Spine
  • 5
    Descending aorta
  • 6
    Left atrium (tip of appendage)
  • 7
    Right atrium
  • 8
    Ascending aorta (can just see tip of the aortic valve between this and the left atrium)

From the four chamber view rotate the probe slightly towards the right shoulder and move the probe slightly in a cephalic direction. 32 This plane will demonstrate the aorta arising from the left ventricle; its medial wall must be seen to be continuous with the interventricular septum to exclude aortic override. Often the aortic valve can be seen opening and closing in the centre of the vessel. The ascending aorta is directed towards the right shoulder and turns back to the left at a higher level to form the aortic arch.

Doppler can be used to demonstrate no turbulence across aortic valve and to ensure that there is the correct direction of flow across this valve.

Figures 21 and 22: Right ventricular outflow tract (RVOT)

Figure 21.

Figure 21

Right ventricular outflow tract.
  • 1
    Right ventricle
  • 2
    Pulmonary valve
  • 3
    Pulmonary trunk
  • 4
    Ductus arteriosus
  • 5
    Descending aorta
  • 6
    Right pulmonary artery
  • 7
    Superior vena cava
  • 8
    Ascending aorta
  • 9
    Right atrium

Still in an axial section move further in a cephalic direction from the four‐chamber view. The pulmonary trunk arises from the right ventricle close to the sternum, it is directed backwards towards spine. 32 The pulmonary trunk divides into the ductus arteriosus which continues directly towards the spine in the midline; and the right pulmonary artery which curves behind ascending aorta and SVC. The left pulmonary artery is not usually visible in this plane; it is directed in a more inferior direction. Bifurcation of the pulmonary trunk into ductus arteriosus and right pulmonary artery is important to establish that the vessel arising from the right ventricle is going to the lungs.

Figures 23 and 24: Three vessels and trachea view (3VT)

Figure 23.

Figure 23

Three vessels and trachea view (3VI).
  • 1
    Pulmonary Arch
  • 2
    Aortic Arch
  • 3
    SVC
  • 4
    Trachea
  • 5
    Spine
  • 6
    Rib

This is the highest transverse plane for evaluating the fetal heart. Move the transducer further in a cephalic direction from the right ventricular outflow tract view, maintaining an axial section. The three vessels are, from left to right: the top of the pulmonary arch, the aortic arch and the SVC. 33 The trachea lies to right of the aorta and behind the SVC and has echogenic walls compared to the other vessels.

A ‘V’ shaped ‘arrowhead’ of aorta and ductus is made at their meeting point; the aorta is now directed towards the left shoulder. The width of the ductus is slightly larger than that of the aorta. In approximately 1% of fetuses an aberrant right subclavian artery can be seen passing behind the trachea towards the right shoulder, this has been associated with an increased risk of trisomy 21. 34

Figures 25 and 26: Aortic arch

This is an oblique sagittal view. The aortic arch arises from the middle of the heart and has a curved ‘walking stick’ shape to its arch. Three head and neck vessels arise from the aorta. The arch can be seen to be continuous with the descending aorta with no arch interruption or narrowing to suggest coarctation.

Doppler Assessment should aim to demonstrate complete filling of the aorta with color, and forward flow away from the heart with no obvious turbulence. Filling of the three head and neck vessels is ideal but not always obtainable.

No turbulence is seen in the arch, the head and neck are identified.

Figures 27 and 28: Ductal arch

Figure 27.

Figure 27

Ductal arch.
  • 1
    Ductal arch arises anteriorly from the heart.
  • 2
    Pulmonary valve
  • 3
    Descending aorta
  • 4
    Heart

This is a mid‐sagittal view of the fetal chest, best obtained with the fetus lying supine. Shadowing from the spine can make this a difficult view to obtain when the fetus is prone. The ductal arch is directed straight back towards the spine with no head and neck vessels arising from it. The ductus arteriosus is continuous with the descending aorta. In contrast to the curved appearance of the aortic arch there is a straight ‘hockey stick’ appearance to the ductal arch. The pulmonary valve can often be visualised opening and closing. No head or neck vessels can be seen arising from this arch.

Figure 29: Fetal heart rate

The heart rate can be observed throughout the fetal heart evaluation. Formal measurement of the heart rate is only a snapshot and there is considerable heart rate variation, especially with fetal movements. Heart rate can be measured with M‐mode or pulse wave Doppler. Pulse wave has an added benefit of allowing the mother to heart the heartbeat but involves higher energy levels. Extra information can be gained by placing the M mode through both a ventricle and atrium to demonstrate the heart rate in both structures.

The normal baseline fetal heart rate in the second trimester is 120–160 beats per minute. A regular rhythm should be demonstrated.

Figure 30: SVC & IVC into the right atrium

This is an optional image not frequently included in the routine examination but it is easy to obtain and is useful when evaluating potential abnormalities. The image is obtained by a para‐sagittal section just to the right of the mid line and just to the right of the ductal arch view.

The superior vena cava and IVC can both be seen entering the right atrium; this can be confirmed with color Doppler assessment.

The fetal abdomen

The abdominal circumference is a standard biometry measurement 6 , 7 (Figure 31). The umbilical cord insertion should be imaged to look for abdominal wall defects (Figure 32). The renal tract is reviewed by imaging urine in the bladder with surrounding umbilical arteries (Figure 33) and assessing the kidneys. The fetal kidneys should be imaged in 2 planes, both coronal and axial (Figures 34 and 35). Although not essential, visualising the renal arteries can help with kidney identification especially if unilateral renal anomalies are suggested (Figure 36).

Figure 31.

Figure 31

Abdominal circumference.
  • 1
    Umbilical vein
  • 2
    Middle portal vein
  • 3
    Stomach
  • 4
    Spine
  • 5
    Rib

Figure 32.

Figure 32

Umbilical cord insertion.
  • 1
    Umbilical arteries
  • 2
    Skin line
  • 3
    Spine

Figure 33.

Figure 33

Bladder and umbilical arteries.
  • 1
    Bladder
  • 2
    Umbilical arteries
  • 3
    Thighs

Figure 34.

Figure 34

Axial kidneys.
  • 1
    Spine
  • 2
    Kidney
  • 3
    Renal pelvis

Figure 35.

Figure 35

Coronal kidneys.
  • 1
    Kidney
  • 2
    Renal pelvis
  • 3
    Aorta
  • 4
    Iliac arteries
  • 5
    Iliac crest

Figure 36.

Figure 36

Renal arteries. Coronal section with the aorta horizontal facilitates demonstrates of flow from the aorta to each renal artery.

Figure 31: Abdominal circumference

This image is a transverse section of the upper part of the fetal abdomen. This view is directly inferior to the 4–chamber view. In difficult cases it can be obtained by placing the fetal spine horizontally across the screen with the stomach visible in the centre of the screen and then rotating the probe 90°.

The stomach should be visualised in the left side of the abdomen. A ‘J’ shaped hypoechoic structure is seen in the midline; it should be 1/3 of the way across the abdomen and represents the internal portion of the umbilical vein branching to the right portal vein.

The Abdominal Circumference is measured around the outside of the skin line. It is important that this section is correctly obtained to minimise measurement error. A number of features can be used to assess if the section is correct: The section should be circular not oval; the kidneys should not be visible in the section; the cord insertion should not be visible; and the ‘J’ should not extend all of the way to the skin line anteriorly (umbilical vein should not be visible to out to the skin line). If these features are incorrect then the section may be oblique and the AC may be overestimated.

Occasionally the gall bladder is visible as a tear shaped hypoechoic structure situated to the right anterior of the umbilical vein. The Adrenal glands can sometimes also be seen in this section. There should be no cystic dilatation of the bowel or abdominal cysts visible.

Figure 32: Umbilical cord insertion

This is a transverse section of the abdomen inferior to the abdominal circumference. The best views are obtained with the cord insertion near the three or nine o'clock position. The skin line should be clearly visualised on both sides of the insertion. The base of the cord should insert cleanly into abdominal wall with no evidence of associated mass to suggest gastroschisis or omphalocele.

Figure 33: Bladder and umbilical arteries

This is a transverse section of the abdomen at the level of the bladder. Fluid should be seen within the bladder at some stage during the examination. A large bladder may be ‘keyhole’ shaped and may indicate urethral obstruction (partial or complete).

Color or power Doppler is used to identify the two umbilical arteries that surround the bladder and then are directed towards the cord insertion.

These arteries need to be traced around the bladder towards the cord insertion to differentiate them from the iliac vessels that are seen more laterally in the pelvis directed towards the thighs. It is important to ensure that the Doppler settings are suitable for low flow to maximise the ability to detect both arteries.

Figure 34: Axial kidneys

This is a transverse section of the abdomen. Placing the spine uppermost obtains the best image. The kidneys can be seen on either side of the spine.

Each hypoechoic renal pelvis can be measured in the anterior posterior direction. The normal renal pelvis measures ≤ 4 mm in the second Trimester. 35

Figure 35: Coronal kidneys

This is a coronal section through the back just anterior to the fetal spine. A kidney should be seen on each side of the aorta. Each kidney is ‘C’ shaped around a single renal pelvis.

The axis of each kidney is roughly parallel to the aorta; if they angle towards each other at the caudal ends then this may indicate a horseshoe kidney. Each kidney should be similar sized (20–22 mm length in the second trimester) with no renal cysts visible.

Figure 36: Renal arteries

This is a coronal section through the back just anterior to the fetal spine, the same section as Coronal Kidneys. Low flow settings are needed to detect both arteries. The arteries should extend all of the way into the renal pelvis.

The fetal musculoskeletal system

It is beneficial to image the fetal spine throughout its length and the spine is best imaged in three planes: coronal, sagittal and axial (Figures 3740).

Figure 37.

Figure 37

Spine and skin line – longitudinal.
  • 1
    Skin line
  • 2
    Bladder
  • 3
    Abdominal Aorta
  • 4
    Vertebrae

Figure 40.

Figure 40

Axial spine images.

Four images of different levels of the spine clockwise from upper left to lower left: cervical spine, thoracic spine, abdominal spine, lumbar spine.
  • 1
    Vertebral body
  • 2
    Ossification centre in vertebral lamina.
  • 3
    Intact skin line
  • 4
    Clavicle
  • 5
    Rib
  • 6
    Heart
  • 7
    Kidney
  • 8
    Iliac crest
  • 9
    Bladder

Each of the twelve long bones should be separately visualised (Figures 4247). Although both femurs could be measured it is probably sufficient to only measure one provided both have been seen to be of similar lengths. When imaging the long bones the operator should ensure they are not angulated or bowed, that they are echogenic and are of an appropriate length. If there is doubt about long bone length then they can each be individually measured and checked against standardised charts. 36 Hands and feet should be separately imaged taking particular care to ensure that both left and right sides are separately seen (Figures 45 and 48).

Figure 42.

Figure 42

Leg bones.

The tibia and fibula are noted to be the same length.
  • 1
    Tibia
  • 2
    Fibula

Figure 47.

Figure 47

Hands.

The hand is best imaged open palmed, the full length of the fingers is seen, and the thumb is not adducted

Figure 45.

Figure 45

Humerus.

The humerus is identified on each arm; the posterior acoustic shadow is noted.

Figure 48.

Figure 48

Male gender sagittal and axial.

The top image and diagram are mid sagittal and demonstrate the genitalia separate to the cord insertion. The bottom axial image and diagram confirms the presence of penis and scrotum between the legs.
  • 1
    Penis
  • 2
    Scrotum
  • 3
    Leg

Figure 37: Spine and skin line – longitudinal

This is a sagittal midline section; best views are obtained if the fetus is prone. There should be an intact skin line i.e. a continuous skin line overlying the back, especially over the sacral region. There should be no spinal angulation or deformity. At the inferior end there should be sacrococcygeal tapering of the spine.

Figure 38: Coronal spine

Figure 38.

Figure 38

Coronal spine.
  • 1
    Iliac crest
  • 2
    Sacrum
  • 3
    Vertebrae
  • 4
    Ribs

This is a coronal image through the back. Often more than one image is required to see the whole spine. The sacrum extends just beyond the iliac wing. Tapering of the spine in the sacrococcygeal region is normal. The examiner should carefully assess for angulation or deformity of the spine and ensure that no hemivertebrae are seen. A slight expansion of the width of the lumbar spine is common.

Figure 39: Coronal spine – sacrum

Figure 39.

Figure 39

Coronal spine – sacrum.
  • 1
    Iliac crest
  • 2
    Sacrum
  • 3
    Vertebrae

This is a coronal image through the back designed to more carefully assess the base of the spine. Sacrococcygeal tapering of the spine is normal; the sacrum extends just below the iliac wing. Separation of the lateral ossification centres or lack of visualisation of the central ossification centres may indicate a spinal defect. Occasionally the central ossification centres are not seen due to shadowing artefact from the adjacent iliac wing, angling away from a true coronal image to an oblique coronal image should help avoid this shadow artefact.

Figure 40: Axial spine images

The whole spine should be assessed in transverse section, this is best done by running up and down the spine in real time but representative images of each part of the spine can be taken. The three ossification centres form an approximately equilateral triangle throughout the length of the spine. Spreading of the laminae to form a more obtuse angled triangle may indicate open spina bifida. The operator should look for an intact skin line over the spine throughout, taking particular attention to ensure that there are no cysts or masses visible on the back.

Figure 41: Femur

Figure 41.

Figure 41

Femur.
  • 1
    Femur
  • 2
    Posterior acoustic shadow

The calcified bone is actually the femoral diaphysis, the epiphyseal ends do not calcify until later in pregnancy. The image should be taken with the femur horizontal (perpendicular to the ultrasound beam). 37 This makes it easier to see the full extent of the bone and avoid foreshortening. When the full length of the femur is on the screen there is often a posterior acoustic shadow noted.

Measure the femur horizontally across the ossified diaphysis down the middle of the shaft of the bone avoiding any triangular echogenic extensions (seldom seen before the third trimester). A measurement less than the 2.5th centile may increase the risk of aneuploidy and raise concerns about skeletal dysplasia. 38

Figure 42: Leg bones and Figure 43: Heel

Figure 43.

Figure 43

Heel.

There is a right angle between the sloe of the foot and the leg bones.
  • 1
    Tibia
  • 2
    Fibula
  • 3
    Heel

Two long bones should be seen in each leg. The tibia and fibula are of equal length. A sagittal side on image of each leg will demonstrate the ankle to be correctly orientated. In order to exclude talipes the heel should be ‘square’ with the sole of the foot orientated at right angles to the leg bones. The sole of the foot and the length of tibia and fibula should not be able to be seen in the same image.

Figure 44: Feet

Figure 44.

Figure 44

Feet.

Five toes are identified on each foot.

This image is used to ensure that there are a correct number of toes on each foot. The leg should not be visible in same plane as the sole of the foot. The second toe can be longer than the great toe. There should be no cleft in the foot. The toes are best counted when they are pointing up towards the transducer.

Figure 45: Humerus

The humerus is best measured with it lying horizontal across the screen (perpendicular to the sound beam). 37 This makes it easier to see the full extent of the bone and avoid foreshortening. Less than the 2.5th centile may increase the risk of aneuploidy and raise concerns about skeletal dysplasia. 38

Figure 46: Forearm

Figure 46.

Figure 46

Forearm.

The ulna is longer than the radius at the elbow.

Normally both bones terminate at the same level at the wrist but the ulna is longer than the radius by 2–3 mm at the elbow. Both ulnas are lower in the images with wrists on the right of each image. It is important to identify the full length of the radius as radial ray defects can occur. 39

Figure 47: Hands

Each hand needs to be separately imaged. Hands need to be seen to open fully at least once during the scanning time, and should be seen to open at least once. If the hands remain clenched throughout the scan then there is a risk of trisomy 18. 40 The thumb should not be persistently adducted. 41

The fetal gender

Rarely genital abnormalities are seen prenatally and therefore it is useful for the sonographer to examine this area. Some departments will allow parents to know the gender of the fetus. If the external genitalia are to be visualised for sex determination then imaging in both mid‐sagittal and axial planes is recommended to minimise error 42 (Figures 4849).

Figure 49.

Figure 49

Female gender sagittal and axial.

The top image and diagram are mid sagittal and demonstrate the flat mons pubis below the cord insertion. The bottom axial image and diagram show the three lines of the labia.
  • 1
    Bladder
  • 2
    Mons pubis
  • 3
    Umbilical cord
  • 4
    Labia
  • 5
    Thigh

Figure 48: Male gender sagittal and axial

The male genitalia are best assessed by taking two images. Firstly a mid‐sagittal image of the lower abdomen below the cord insertion demonstrates penis and scrotum caudally to the cord insertion. Secondly a transverse image, just below the level of the bladder, best taken with the knees separated. Penis and scrotum are seen between the thighs in this image. Testes are undescended at this gestation, and usually descend later in the third trimester.

Figure 49: Female Gender sagittal and axial

As with the male genitalia the female external genitalia are best assessed by looking from two directions. The first image is a mid‐sagittal image of the lower abdomen demonstrating the flat mons pubis caudal to the cord insertion. Secondly a transverse image, just below the level of the bladder, best taken with the knees separated. No penis is seen between the thighs, rather there are three lines representing the labia visible.

Other structures

The placenta should be visualised throughout to look for abnormalities, placenta previa, or hemorrhages (Figure 50). The operator should check the entire internal surface of the myometrium to ensure that there is no succenturiate lobe. The position of the placenta needs to be established to see if it is close to the internal os (Figure 51). The maternal cervical canal can also be measured, preferably with an empty or near empty maternal bladder (Figure 51).

Figure 50.

Figure 50

Placenta and cord insertion.

The cord inserts centrally into an anterior placenta. Identification of the insertion point is facilitated by the use of color or power Doppler.

Figure 51.

Figure 51

Placental site and cervical length.
  • 1
    Placenta
  • 2
    Lower placental edge
  • 3
    Cervical canal
  • 4
    Fetal limbs

Color or power Doppler over the internal os may help exclude vasa previa (Figure 52). If there is any suspicion of shortening of the cervix or low lying placenta then a transvaginal scan often provides more accurate measurements43 (Figure 53). Many centres will perform a transvaginal scan to assess the placental site and cervix more accurately if there is any doubt about placental position.

Figure 52.

Figure 52

Doppler over the internal os.

No vasa praevia is seen overlying the internal os

Figure 53.

Figure 53

Transvaginal cervical length.

The hypoechoic cervical canal is demonstrated; the vaginal probe is not sitting hard up against the cervix and therefore is not artificially elongating the cervical canal measurement.
  • 1
    Cervical canal
  • 2
    Fetal head
  • 3
    Maternal bladderz

A review of the uterine wall looking for fibroids or bicornuate uterus and a review of the adnexae for ovarian cysts is suggested (these images are not presented in this publication).

Figure 50: Placenta and cord insertion

The placenta is quite uniform in appearance at this gestation. Small hypoechoic vascular lakes can appear and do not appear significant. 44 These usually will not show flow with power Doppler. Large lakes, greater than 2 cm by 2 cm, may increase the risk of small for gestational age in the third trimester. 45 The placenta should be less than 4 cm thick. 46

It is advisable to scan through the placenta to attempt to find where the cord inserts into the placental mass. 47 This is easy with an anterior placenta but can be difficult to locate if the fetus is lying on a posterior cord insertion. If the cord inserts to the margin of the placenta then it should be reported as a marginal insertion and it is helpful to specify the side of insertion (e.g. upper left, lower right). If the cord inserts into the uterine wall and vessels then course around the wall to insert into the side of the placenta then this is described as a velamentous insertion. Either marginal or velamentous insertions can increase the risk of succenturiate lobes and vasa previa. These abnormalities should be scanned for carefully. 48

Figures 51 and 52: Placental site and cervical length

This image is obtained by taking a mid‐sagittal view through the cervix. Ensure that the cervical canal can be seen as a hypoechoic line. The closest edge of the placenta should be located; sometimes this is not in the mid line but situated more laterally. The distance from the lowest edge of the placenta to the internal os should then be measured. A low lying placenta is suggested if the placenta lies less than two cm from internal os. 49 Accurate measurements cannot be obtained with a contraction of the myometrium occurring and time must be given for this to relax. Many centres will perform a transvaginal scan to assess the placental site more accurately if there is any doubt about placental position. 50 Color or power Doppler over the internal os is a quick technique to exclude a vasa previa. Occasionally the cord is draped over the cervix and this can lead to erroneous diagnosis of vasa previa, it is worthwhile checking again after asking the mother to roll from side to side to see if the cord moves to a different position.

Placing a Doppler box over the internal os is useful to exclude vasa previa (Figure 52). One must be sure that any vessel seen is not just a mobile loop of umbilical cord. If a vasa previa is found an attempt at locating a succenturiate lobe should also be made.

Figure 53: Transvaginal cervical length

If a measurement of cervical length is requested (usually because of a risk factor for cervical incompetence), or the cervix appears short on abdominal views, the cervix should be assessed transvaginally with an empty bladder. 51 The operator should aim to obtain a mid‐sagittal view of the cervix demonstrating the hypoechoic cervical canal. Withdrawing the vaginal probe a short way is useful to ensure the probe is not pressing on the cervix as pressure on the cervix may artificially elongate the cervical measurement and may prevent opening of the canal with fundal pressure. The cervix should be measured with and without fundal pressure. 52 The shortest length measured with fundal pressure is the most important measurement. 51

Conclusion

The authors have provided a selection of images which we feel are suitable for a comprehensive screening examination. Other images will be required if an abnormality is suspected or detected. Prenatal ultrasound is a rapidly developing field and other structures may become important in future years and these may require different or extra images.

Not all departments will require each of the images presented in this manuscript to be obtained at each ultrasound. The authors are not suggesting that a second trimester examination is only complete if all these images are presented. Rather the authors hope that presenting these labelled images will help with education and understanding of the important structures, which can be visualised at a second trimester anatomy survey. It may not be possible to see every structure in some patients due to fetal position or maternal size. This manuscript may find value as a pictorial reference in imaging departments.

References

  • 1. Chitty LS, Hunt GH, Moore J, Lobb MO. Effectiveness of routine ultrasonography in detecting fetal structural abnormalities in a low risk population. BMJ 1991; 303 (6811): 1165–69. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Nisbet DL, Robertson AC, Schluter PJ, McLennan AC, Hyett JA. Auditing ultrasound assessment of fetal nuchal translucency thickness: a review of Australian National Data 2002–2008. Aust N Z J Obstet Gynaecol 2010; 50 (5): 450–55. [DOI] [PubMed] [Google Scholar]
  • 3. Vintzileos AM, Ananth CV, Smulian JC, Beazoglou T, Knuppel RA. Routine second‐trimester ultrasonography in the United States: a cost‐benefit analysis. Am J Obstet Gynecol 2000; 182 (3): 655–60. [DOI] [PubMed] [Google Scholar]
  • 4. American Institute of Ultrasound in Medicine . AIUM standard for documentation of an ultrasound examination. American Institute of Ultrasound in Medicine. J Ultrasound Med 2002; 21 (10): 1188–89. [DOI] [PubMed] [Google Scholar]
  • 5. ASUM D2 . Australasian Society for Ultrasound in Medicine – Guidelines for the mid Trimester Obstetrics Scan Last Revised July 2005. Available at http://www.asum.com.au/newsite/files/documents/policies/PS/D2_policy.pdf. Accessed October 2012
  • 6. Salomon LJ, Alfirevic Z, Berghella V, Bilardo C, Hernandez‐Andrade E, Johnsen SL, et al, and the ISUOG Clinical Standards Committee . Practice guidelines for performance of the routine mid‐trimester fetal ultrasound scan. Ultrasound Obstet Gynecol 2011; 37 (1): 116–26. [DOI] [PubMed] [Google Scholar]
  • 7. American Institute of Ultrasound in Medicine . AIUM practice guideline for the performance of an antepartum obstetric ultrasound examination. J Ultrasound Med 2003; 22: 1116–25. [DOI] [PubMed] [Google Scholar]
  • 8. Johnsen SL, Rasmussen S. Sollien Accuracy of second trimester fetal head circumference and biparietal diameter for predicting the time of spontaneous birth. J Perinat Med 2006; 34 (5): 367–70. [DOI] [PubMed] [Google Scholar]
  • 9. Magann EF, Chauhan SP, Whitworth NS, Isler C, Wiggs C, Morrison JC. Subjective versus objective evaluation of amniotic fluid volume of pregnancies of less than 24 weeks' gestation: how can we be accurate? J Ultrasound Med 2001; 20: 191–95. [DOI] [PubMed] [Google Scholar]
  • 10. Rink BD. Arthrogryposis: a review and approach to prenatal diagnosis. Obstet Gynecol Surv 2011; 66 (6): 369–77. [DOI] [PubMed] [Google Scholar]
  • 11. Rypens F, Dubois J, Garel L, Fournet JC, Michaud JL, Grignon A. Obstetric US: watch the fetal hands. Radiographics 2006; 26 (3): 811–29. [DOI] [PubMed] [Google Scholar]
  • 12. International Society of Ultrasound in Obstetrics and Gynecology . Sonographic examination of the fetal central nervous system: guidelines for performing the ‘basic examination’ and the ‘fetal neurosonogram’. Ultrasound Obstet Gynecol 2007; 29: 109–16. [DOI] [PubMed] [Google Scholar]
  • 13. Bromley B, Benacerraf BR. Difficulties in the prenatal diagnosis of microcephaly. J Ultrasound Med 1995; 14: 303–05. [DOI] [PubMed] [Google Scholar]
  • 14. Cardoza JD, Goldstein RB, Filly RA. Exclusion of fetal ventriculomegaly with a single measurement: the width of the lateral ventricular atrium. Radiology 1988; 169: 711–14. [DOI] [PubMed] [Google Scholar]
  • 15. Winter TC, Kennedy AM, Byrne J, Woodward PJ. The cavum septi pellucidi: why is it important? J Ultrasound Med 2010; 29: 427–44. [DOI] [PubMed] [Google Scholar]
  • 16. Snijders RJ, Nicolaides KH. Fetal Biometry at 14–40 weeks' gestation. Ultrasound Obstet Gynecol 1994; 4: 34–48. [DOI] [PubMed] [Google Scholar]
  • 17. Filly RA, Cardoza JD, Goldstein RB, Barkovich AJ. Detection of fetal central nervous system anomalies: a practical level of effort for a routine sonogram. Radiology 1989; 172: 403–08. [DOI] [PubMed] [Google Scholar]
  • 18. Achiron R, Achiron A. Development of the human fetal corpus callosum: a high‐resolution, cross‐sectional sonographic study. Ultrasound Obstet Gynecol 2001; 18: 343–47. [DOI] [PubMed] [Google Scholar]
  • 19. Malinger G, Ginath S, Lerman‐Sagie T, Watemberg N, Lev D, Glezerman M. The fetal cerebellar vermis: normal development as shown by transvaginal ultrasound. Prenat Diagn 2001; 21 (8): 687–92. [DOI] [PubMed] [Google Scholar]
  • 20. Kurjak A, Azumendi G, Andonotopo W, Salihagic‐Kadic A. Three‐ and four‐dimensional ultrasonography for the structural and functional evaluation of the fetal face. Am J Obstet Gynecol 2007; 196 (1): 16–28. [DOI] [PubMed] [Google Scholar]
  • 21. Rotten D, Levaillant JM, Martinez H, Ducou le Pointe, H , Vicaut E. The fetal mandible: a 2D and 3D sonographic approach to the diagnosis of retrognathia and micrognathia. Ultrasound Obstet Gynecol 2002; 19 (2): 122–30. [DOI] [PubMed] [Google Scholar]
  • 22. Sonek JD, Nicolaides KH. Prenatal ultrasonographic diagnosis of nasal bone abnormalities in three fetuses with Down syndrome. Am J Obstet Gynecol 2002; 186: 139–41. [DOI] [PubMed] [Google Scholar]
  • 23. Mogra R, Schluter P, Ogle R, Walter M, Borg M, Hyett J. Normal ranges for fetal nasal bone length determined by ultrasound at 18–20 weeks of gestation in a multiethnic Australian population. Aust N Z J Obstet Gynaecol 2011; 51: 347–52. [DOI] [PubMed] [Google Scholar]
  • 24. Odibo AO, Sehdev HM, Stamilio DM, Cahill A, Dunn L, Macones GA. Defining nasal bone hypoplasia in second‐trimester Down syndrome screening: does the use of multiples of the median improve screening efficacy? Am J Obstet Gynecol 2007; 197: 361. e1–361.e4. [DOI] [PubMed] [Google Scholar]
  • 25. Cicero S, Sonek JD, McKenna DS, Croom CS, Johnson L, Nicolaides KH. Nasal bone hypoplasia in trisomy 21 at 15–22 weeks' gestation. Ultrasound Obstet Gynecol 2003; 21 (1): 15–18. [DOI] [PubMed] [Google Scholar]
  • 26. Luedders DW, Bohlmann MK, Germer U, Axt‐Fliedner R, Gembruch U, Weichert J. Fetal micrognathia: objective assessment and associated anomalies on prenatal sonogram. Prenat Diagn 2011; 31 (2): 146–51. [DOI] [PubMed] [Google Scholar]
  • 27. Ozkutlu S, Bostan OM, Deren O, Onderoğlu L, Kale G, Güçer S, et al. Prenatal echocardiographic diagnosis of cardiac right/left axis and malpositions according to standardized Cordes technique. Anadolu Kardiyol Derg 2011; 11 (2): 131–36. [DOI] [PubMed] [Google Scholar]
  • 28. Cordes TM, O'Leary PW, Seward JB, Hagler DJ. Distinguishing right from left: a standardized technique for fetal echocardiography. J Am Soc Echocardiogr 1994; 7: 47–53. [DOI] [PubMed] [Google Scholar]
  • 29. Yagel S, Cohen SM, Achiron R. Examination of the fetal heart by five short‐axis views: a proposed screening method for comprehensive cardiac evaluation. Ultrasound Obstet Gynecol 2001; 17: 367–69. [DOI] [PubMed] [Google Scholar]
  • 30. Di Salvo DN, Brown DL, Doubilet P M, Benson CB, and Frates MC. Clinical significance of isolated fetal pericardial effusion. JUM 1994; 13: 291–3. [DOI] [PubMed] [Google Scholar]
  • 31. Eggebø TM, Heien C, Berget M, Ellingsen CL. Routine use of color Doppler in fetal heart scanning in a low‐risk population. ISRN Obstet Gynecol 2012: 496935. Epub 2012 May 20. [DOI] [PMC free article] [PubMed]
  • 32. International Society of Ultrasound in Obstetrics and Gynecology . Cardiac screening examination of the fetus: guidelines for performing the ‘basic’ and ‘extended basic’ cardiac scan. Ultrasound Obstet Gynecol 2006; 27: 107–13. [DOI] [PubMed] [Google Scholar]
  • 33. Yagel S, Arbel R, Anteby EY, Raveh D, Achiron R. The three vessels and trachea view (3VT) in fetal cardiac scanning. Ultrasound Obstet Gynecol 2002; 20 (4): 340–45. [DOI] [PubMed] [Google Scholar]
  • 34. Borenstein M, Minekawa R, Zidere V, Nicolaides KH, Allan LD. Aberrant right subclavian artery at 16 to 23 + 6 weeks of gestation: a marker for chromosomal abnormality. Ultrasound Obstet Gynecol 2010; 36: 548–52. [DOI] [PubMed] [Google Scholar]
  • 35. Benacerraf BR, Mandell J, Estroff JA, Harlow BL, Frigoletto FD Jr. Fetal pyelectasis: a possible association with Down syndrome. Obstet Gynecol 1990; 76: 58–60. [PubMed] [Google Scholar]
  • 36. Chitty LS, Altman DG. Charts of fetal size: limb bones. BJOG 2002; 109 (8): 919–29. [DOI] [PubMed] [Google Scholar]
  • 37. Lessoway VA, Schulzer M, Wittmann BK. Sonographic measurement of the fetal femur: factors affecting accuracy. J Clin Ultrasound 1990; 18: 471–76. [DOI] [PubMed] [Google Scholar]
  • 38. Bethune M. Literature review and suggested protocol for managing ultrasound soft markers for Down syndrome: Thickened nuchal fold, echogenic bowel, shortened femur, shortened humerus, pyelectasis and absent or hypoplastic nasal bone. Australas Radiol 2007; 51: 218–25. [DOI] [PubMed] [Google Scholar]
  • 39. Kennelly MM, Moran P. A clinical algorithm of prenatal diagnosis of Radial Ray Defects with two and three dimensional ultrasound. Prenat Diagn 2007; 27 (8): 730–37. [DOI] [PubMed] [Google Scholar]
  • 40. Bronsteen R, Lee W, Vettraino IM, Huang R, Comstock CH. Second‐trimester sonography and trisomy 18: the significance of isolated choroid plexus cysts after an examination that includes the fetal hands. J Ultrasound Med 2004; 23: 241–45. [DOI] [PubMed] [Google Scholar]
  • 41. Ghani Hisham Abdel. El‐Naggar A, Hegazy M, Hanna A, Tarraf Y, Temtamy S. Characteristics of patients with congenital clasped thumb: a prospective study of 40 patients with the results of treatment. J Child Orthop 2007; 1 (5): 313–22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42. Meagher S, Davison G. Early second‐trimester determination of fetal gender by ultrasound. Ultrasound Obstet Gynecol 1996; 8: 322–24. [DOI] [PubMed] [Google Scholar]
  • 43. Iams JD. Cervical ultrasonography. Ultrasound Obstet Gynecol 1997; 10: 156–60. [DOI] [PubMed] [Google Scholar]
  • 44. Thompson MO, Vines SK, Aquilina J, Wathen NC, Harrington K. Are placental lakes of any clinical significance? Placenta 2002; 23 (8–9): 685–90. [DOI] [PubMed] [Google Scholar]
  • 45. Hwang HS, Sohn IS, Kwon HS. The clinical significance of large placental lakes. Eur J Obstet Gynecol Reprod Biol 2012; 162 (2): 139–43. [DOI] [PubMed] [Google Scholar]
  • 46. Lee AJ, Bethune M, Hiscock RJ. Placental thickness in the second trimester: a pilot study to determine the normal range. J Ultrasound Med 2012; 31 (2): 213–18. [DOI] [PubMed] [Google Scholar]
  • 47. Sepulveda W, Rojas I, Robert JA, Schnapp C, Alcalde JL. Prenatal detection of velamentous insertion of the umbilical cord: a prospective color Doppler ultrasound study. Ultrasound Obstet Gynecol 2003; 21: 564–69. [DOI] [PubMed] [Google Scholar]
  • 48. Rao KP, Belogolovkin V, Yankowitz J, Spinnato JA 2nd. Abnormal placentation: evidence‐based diagnosis and management of placenta previa, placenta accreta, and vasa previa. Obstet Gynecol Surv 2012; 67 (8): 503–19. [DOI] [PubMed] [Google Scholar]
  • 49. Bhide A, Thilaganathan B. Recent advances in the management of placenta previa. Curr Opin Obstet Gynecol 2004; 16 (6): 447–51. [DOI] [PubMed] [Google Scholar]
  • 50. Royal College of Obstetricians and Gynaecologists . Guideline No. 27. Placenta Praevia and Placenta Praevia Accreta: Diagnosis and Management. RCOG: London, October, 2005. [Google Scholar]
  • 51. Owen J, Yost N, Berghella V, Thom E, Swain GA, Dildy GA 3rd, et al. Mid‐trimester endovaginal sonography in women at high risk for spontaneous preterm birth. JAMA 2001; 286: 1340–48. [DOI] [PubMed] [Google Scholar]
  • 52. Guzman ER, Rosenberg JC, Houlihan C, Ivan J, Waldron R, Knuppel R. A new method using vaginal ultrasound and transfundal pressure to evaluate the asymptomatic incompetent cervix. Obstet Gynecol 1994; 83: 248–52. [PubMed] [Google Scholar]

Articles from Australasian Journal of Ultrasound in Medicine are provided here courtesy of Australasian Society for Ultrasound in Medicine