Abstract
The design and use of a new device for obtaining corneoscleral buttons for storage and corneal discs for keratoplasty from neonatal and adult donor eyes is described. The device is simple to use and eliminates most of the difficulties in handling infant donor eyes. It thus minimises the risk of damage to the corneal endothelium and the formation of stretch striae, which reduce the quality of the donor material for transplantation.
Full text
PDF



Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Fong L. P., Gladstone D., Casey T. A. Corneo-scleral rim cultures: donor contamination a case of fungal endophthalmitis transmitted by K-Sol stored cornea. Eye (Lond) 1988;2(Pt 6):670–676. doi: 10.1038/eye.1988.123. [DOI] [PubMed] [Google Scholar]
- Grutzmacher R. D., Oiland D., McKillop B. R., Bunt-Milam A. H. Donor corneal endothelial striae. Am J Ophthalmol. 1986 Oct 15;102(4):508–515. doi: 10.1016/0002-9394(86)90082-6. [DOI] [PubMed] [Google Scholar]
- Hartmann C., Rieck P. A new test for endothelial viability. The Janus green photometry technique. Arch Ophthalmol. 1989 Oct;107(10):1511–1515. doi: 10.1001/archopht.1989.01070020585045. [DOI] [PubMed] [Google Scholar]
- Nartey I. N., Sherrard E. S., Steele A. D. Manipulative damage to the endothelium of infant and adult donor corneas. Br J Ophthalmol. 1990 May;74(5):261–264. doi: 10.1136/bjo.74.5.261. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pfister R. R., Breaud S. Aphakic refractive penetrating keratoplasty using newborn donor corneas. A preliminary report on an alternative approach to refractive correction. Ophthalmology. 1983 Oct;90(10):1207–1212. doi: 10.1016/s0161-6420(83)34417-1. [DOI] [PubMed] [Google Scholar]
- Roozitalab M. H., Requard J. J., Fogle J. A., Green W. R., Graham C. R., Jr Endothelial stretch striae in donor cornea: cause, significance and prevention. Md State Med J. 1979 May;28(5):47–49. [PubMed] [Google Scholar]
- Steele A. D., Pierse D. Mastering the donor eye: a new device for obtaining donor corneal discs. Br J Ophthalmol. 1978 Feb;62(2):86–88. doi: 10.1136/bjo.62.2.86. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Taylor M. J., Hunt C. J. Dual staining of corneal endothelium with trypan blue and alizarin red S: importance of pH for the dye-lake reaction. Br J Ophthalmol. 1981 Dec;65(12):815–819. doi: 10.1136/bjo.65.12.815. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wilson S. E., Bourne W. M. Corneal preservation. Surv Ophthalmol. 1989 Jan-Feb;33(4):237–259. doi: 10.1016/0039-6257(82)90150-3. [DOI] [PubMed] [Google Scholar]
- Wood T. O., Nissenkorn I. Infant donor corneas for penetrating keratoplasty. Ophthalmic Surg. 1981 Jul;12(7):500–502. [PubMed] [Google Scholar]
- van Delft J. L., Oosterhuis J. A., Barthen E. R., Eijkelenboom A. M. Janus green vital staining of the cornea. Doc Ophthalmol. 1983 Feb 28;55(1-2):47–50. doi: 10.1007/BF00140460. [DOI] [PubMed] [Google Scholar]






