Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1992 Dec;76(12):719–722. doi: 10.1136/bjo.76.12.719

Contrast sensitivity and glare in cataract using the Pelli-Robson chart.

T H Williamson 1, N P Strong 1, J Sparrow 1, R K Aggarwal 1, R Harrad 1
PMCID: PMC504390  PMID: 1486072

Abstract

There is a need for a convenient, clinically applicable test of glare disability which can be used in the preoperative evaluation of patients with cataract. In this study, contrast sensitivity (using the Pelli-Robson letter chart), near vision, and visual acuity were compared, with and without the introduction of a glare source in 70 patients with cataract, 15 with intraocular lenses, and 19 controls. A disposable pen torch was shone at the pupillary margin to induce glare. Contrast sensitivity demonstrated the most marked reduction during glare testing. Cortical cataracts were most affected followed by posterior subcapsular opacities. The glare disability was significantly less in pseudophakic patients and was absent from patients with non-cataractous phakic eyes. Glare testing with a disposable pen torch and a Pelli-Robson contrast sensitivity letter chart provides a rapid test of glare disability which can be easily incorporated into the clinical appraisal of patients with cataract.

Full text

PDF
719

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Abrahamsson M., Sjöstrand J. Impairment of contrast sensitivity function (CSF) as a measure of disability glare. Invest Ophthalmol Vis Sci. 1986 Jul;27(7):1131–1136. [PubMed] [Google Scholar]
  2. Elliott D. B., Gilchrist J., Hurst M., Pickwell L. D., Sheridan M., Weatherill J., Whitaker D. The subjective assessment of cataract. Ophthalmic Physiol Opt. 1989 Jan;9(1):16–19. doi: 10.1111/j.1475-1313.1989.tb00798.x. [DOI] [PubMed] [Google Scholar]
  3. Hess R., Woo G. Vision through cataracts. Invest Ophthalmol Vis Sci. 1978 May;17(5):428–435. [PubMed] [Google Scholar]
  4. Hirsch R. P., Nadler M. P., Miller D. Clinical performance of a disability glare tester. Arch Ophthalmol. 1984 Nov;102(11):1633–1636. doi: 10.1001/archopht.1984.01040031323017. [DOI] [PubMed] [Google Scholar]
  5. Hirsch R. P., Nadler M. P., Miller D. Glare measurement as a predictor of outdoor vision among cataract patients. Ann Ophthalmol. 1984 Oct;16(10):965–968. [PubMed] [Google Scholar]
  6. Maltzman B. A., Horan C., Rengel A. Penlight test for glare disability of cataracts. Ophthalmic Surg. 1988 May;19(5):356–358. [PubMed] [Google Scholar]
  7. Nadler D. J., Jaffe N. S., Clayman H. M., Jaffe M. S., Luscombe S. M. Glare disability in eyes with intraocular lenses. Am J Ophthalmol. 1984 Jan;97(1):43–47. doi: 10.1016/0002-9394(84)90444-6. [DOI] [PubMed] [Google Scholar]
  8. Paulsson L. E., Sjöstrand J. Contrast sensitivity in the presence of a glare light. Theoretical concepts and preliminary clinical studies. Invest Ophthalmol Vis Sci. 1980 Apr;19(4):401–406. [PubMed] [Google Scholar]
  9. Prager T. C., Urso R. G., Holladay J. T., Stewart R. H. Glare testing in cataract patients: instrument evaluation and identification of sources of methodological error. J Cataract Refract Surg. 1989 Mar;15(2):149–157. doi: 10.1016/s0886-3350(89)80003-3. [DOI] [PubMed] [Google Scholar]
  10. Sjöstrand J., Abrahamsson M., Hård A. L. Glare disability as a cause of deterioration of vision in cataract patients. Acta Ophthalmol Suppl. 1987;182:103–106. doi: 10.1111/j.1755-3768.1987.tb02603.x. [DOI] [PubMed] [Google Scholar]
  11. Weatherill J., Yap M. Contrast sensitivity in pseudophakia and aphakia. Ophthalmic Physiol Opt. 1986;6(3):297–301. [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES