Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1993 Mar;77(3):152–157. doi: 10.1136/bjo.77.3.152

Continuous curvilinear (circular) capsulorhexis and planned extracapsular cataract extraction--are they compatible?

M Pande 1
PMCID: PMC504460  PMID: 8457506

Abstract

The successful use of continuous curvilinear (circular) capsulorhexis (CCC) in planned extracapsular cataract extraction (ECCE) is dependent on the feasibility of safe nuclear delivery through the smaller anterior capsular opening. Experimental evidence supports the proposition that the anterior capsular rim can stretch without tearing to dimensions which allow for safe nucleus delivery. Clinical reports of accidental intracapsular expression during nucleus delivery in CCC seemingly contradict the experimental evidence. This paper examines this apparent contradiction and presents clinical evidence in the form of a series of 210 cases of planned ECCE with CCC. The technique used and a detailed analysis of the operative complications are presented. The results indicate that using a modified technique for nucleus delivery, CCC and planned ECCE are fully compatible techniques.

Full text

PDF
152

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Almallah O. F. Capsulorhexis complications with planned extracapsular cataract extraction. J Cataract Refract Surg. 1989 Mar;15(2):232–233. doi: 10.1016/s0886-3350(89)80019-7. [DOI] [PubMed] [Google Scholar]
  2. Assia E. I., Apple D. J., Tsai J. C., Lim E. S. The elastic properties of the lens capsule in capsulorhexis. Am J Ophthalmol. 1991 May 15;111(5):628–632. doi: 10.1016/s0002-9394(14)73710-9. [DOI] [PubMed] [Google Scholar]
  3. Choyce D. P. Polycarbonate intraocular lenses. J Cataract Refract Surg. 1989 Jul;15(4):464–465. doi: 10.1016/s0886-3350(89)80076-8. [DOI] [PubMed] [Google Scholar]
  4. Corydon L., Thim K. Continuous circular capsulorhexis and nucleus delivery in planned extracapsular cataract extraction. J Cataract Refract Surg. 1991 Sep;17(5):628–632. doi: 10.1016/s0886-3350(13)81053-x. [DOI] [PubMed] [Google Scholar]
  5. Gimbel H. V., Neuhann T. Development, advantages, and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990 Jan;16(1):31–37. doi: 10.1016/s0886-3350(13)80870-x. [DOI] [PubMed] [Google Scholar]
  6. Harris D. J., Jr, Specht C. S. Intracapsular lens delivery during attempted extracapsular cataract extraction. Association with capsulorrhexis. Ophthalmology. 1991 May;98(5):623–627. doi: 10.1016/s0161-6420(91)32241-3. [DOI] [PubMed] [Google Scholar]
  7. Maher J. F. Nucleus expression after capsulorhexis. J Cataract Refract Surg. 1988 Nov;14(6):693–693. doi: 10.1016/s0886-3350(88)80050-6. [DOI] [PubMed] [Google Scholar]
  8. Nishi O. Vitreous loss in posterior chamber lens implantation. J Cataract Refract Surg. 1987 Jul;13(4):424–427. doi: 10.1016/s0886-3350(87)80044-5. [DOI] [PubMed] [Google Scholar]
  9. O'Donnell F. E., Jr, Santos B. Posterior capsular-zonular disruption in planned extracapsular surgery. Arch Ophthalmol. 1985 May;103(5):652–653. doi: 10.1001/archopht.1985.01050050044013. [DOI] [PubMed] [Google Scholar]
  10. Thim K., Krag S., Corydon L. Stretching capacity of capsulorhexis and nucleus delivery. J Cataract Refract Surg. 1991 Jan;17(1):27–31. doi: 10.1016/s0886-3350(13)80980-7. [DOI] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES