Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1994 Aug;78(8):618–620. doi: 10.1136/bjo.78.8.618

Prediction of enophthalmos by computed tomography after 'blow out' orbital fracture.

R W Whitehouse 1, M Batterbury 1, A Jackson 1, J L Noble 1
PMCID: PMC504886  PMID: 7918289

Abstract

In 11 patients with blow out fracture of the orbit, measurement of orbital volume using computed tomography (CT) more than 20 days after injury correlated well with enophthalmos measured from the same scans (r = 0.87, p < 0.001, SEE 0.63 mm), with a 1 cm3 increase in orbital volume causing 0.8 mm of enophthalmos. This confirms the cause of enophthalmos after blow out fracture to be increase in orbital volume rather than fat atrophy or fibrosis. In a further 25 patients scanned within 20 days of injury the degree of enophthalmos was less marked than would be predicted from the orbital volume measurement. This was probably because of the presence of oedema, haemorrhage, or both behind the globe which would prevent immediate development of enophthalmos. CT measurement of orbital volume within 20 days of injury may predict the final degree of enophthalmos and identify those patients at risk of late enophthalmos, allowing appropriate early surgical intervention.

Full text

PDF
618

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bite U., Jackson I. T., Forbes G. S., Gehring D. G. Orbital volume measurements in enophthalmos using three-dimensional CT imaging. Plast Reconstr Surg. 1985 Apr;75(4):502–508. doi: 10.1097/00006534-198504000-00009. [DOI] [PubMed] [Google Scholar]
  2. Charteris D. G., Chan C. H., Whitehouse R. W., Noble J. L. Orbital volume measurement in the management of pure blowout fractures of the orbital floor. Br J Ophthalmol. 1993 Feb;77(2):100–102. doi: 10.1136/bjo.77.2.100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Converse J. M. On the treatment of blow-out fractures of the orbit. Plast Reconstr Surg. 1978 Jul;62(1):100–104. doi: 10.1097/00006534-197807000-00016. [DOI] [PubMed] [Google Scholar]
  4. Cooper W. C. A method for volume determination of the orbit and its contents by high resolution axial tomography and quantitative digital image analysis. Trans Am Ophthalmol Soc. 1985;83:546–609. [PMC free article] [PubMed] [Google Scholar]
  5. Forbes G., Gehring D. G., Gorman C. A., Brennan M. D., Jackson I. T. Volume measurements of normal orbital structures by computed tomographic analysis. AJR Am J Roentgenol. 1985 Jul;145(1):149–154. doi: 10.2214/ajr.145.1.149. [DOI] [PubMed] [Google Scholar]
  6. Hammerschlag S. B., Hughes S., O'Reilly G. V., Weber A. L. Another look at blow-out fractures of the orbit. AJR Am J Roentgenol. 1982 Jul;139(1):133–137. doi: 10.2214/ajr.139.1.133. [DOI] [PubMed] [Google Scholar]
  7. Hawes M. J., Dortzbach R. K. Surgery on orbital floor fractures. Influence of time of repair and fracture size. Ophthalmology. 1983 Sep;90(9):1066–1070. doi: 10.1016/s0161-6420(83)80049-9. [DOI] [PubMed] [Google Scholar]
  8. Jackson A., Whitehouse R. W. Low-dose computed tomographic imaging in orbital trauma. Br J Radiol. 1993 Aug;66(788):655–661. doi: 10.1259/0007-1285-66-788-655. [DOI] [PubMed] [Google Scholar]
  9. Koornneef L., Zonneveld F. W. The role of direct multiplanar high resolution CT in the assessment and management of orbital trauma. Radiol Clin North Am. 1987 Jul;25(4):753–766. [PubMed] [Google Scholar]
  10. Manson P. N., Clifford C. M., Su C. T., Iliff N. T., Morgan R. Mechanisms of global support and posttraumatic enophthalmos: I. The anatomy of the ligament sling and its relation to intramuscular cone orbital fat. Plast Reconstr Surg. 1986 Feb;77(2):193–202. [PubMed] [Google Scholar]
  11. Manson P. N., Grivas A., Rosenbaum A., Vannier M., Zinreich J., Iliff N. Studies on enophthalmos: II. The measurement of orbital injuries and their treatment by quantitative computed tomography. Plast Reconstr Surg. 1986 Feb;77(2):203–214. [PubMed] [Google Scholar]
  12. McGurk M., Whitehouse R. W., Taylor P. M., Swinson B. Orbital volume measured by a low-dose CT scanning technique. Dentomaxillofac Radiol. 1992 May;21(2):70–72. doi: 10.1259/dmfr.21.2.1397459. [DOI] [PubMed] [Google Scholar]
  13. Parsons G. S., Mathog R. H. Orbital wall and volume relationships. Arch Otolaryngol Head Neck Surg. 1988 Jul;114(7):743–747. doi: 10.1001/archotol.1988.01860190047020. [DOI] [PubMed] [Google Scholar]
  14. Pathria M. N., Blaser S. I. Diagnostic imaging of craniofacial fractures. Radiol Clin North Am. 1989 Sep;27(5):839–853. [PubMed] [Google Scholar]
  15. Pearl R. M. Surgical management of volumetric changes in the bony orbit. Ann Plast Surg. 1987 Oct;19(4):349–358. doi: 10.1097/00000637-198710000-00011. [DOI] [PubMed] [Google Scholar]
  16. Sanderov B., Viccellio P. Fractures of the medial orbital wall. Ann Emerg Med. 1988 Sep;17(9):973–976. doi: 10.1016/s0196-0644(88)80681-4. [DOI] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES