Abstract
BACKGROUND--The National Eye Institute (NEI) computer planimetry system has proved to be helpful in cross sectional studies by providing clinically useful area measurements of posterior subcapsular cataracts (PSC) and other opacities from retroillumination photographs. In this study, we evaluated the worth of this system in detecting PSC area changes over time. METHODS--Using the Neitz-Kawara camera, retroillumination photographs of the PSCs of 51 eyes were obtained every 6 months for an average of 25 months. The PSCs were outlined in a masked fashion on plastic overlays. Their tracings were then digitised on to a computer using a scanner. PSC area was determined using a special software program. For each eye, the rate of PSC area change was estimated by the slope of the regression line fitted to the follow up measurements. Cataract progression was classified as significant if the slope exceeded a critical value. RESULTS--These showed that 14 of the 51 eyes had PSC progression, while 37 did not change. CONCLUSION--This study suggests the system is useful for longitudinally monitoring PSC area changes from retroillumination photographs. This system would serve in natural history studies of PSCs and in clinical trials of anticataract drugs. The slope based test can play a part in longitudinal studies with irregular time intervals and variable number of visits.
Full text
PDF





Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Adrien Shun-Shin G., Brown N. P., Bron A. J., Sparrow J. M. Dynamic nature of posterior subcapsular cataract. Br J Ophthalmol. 1989 Jul;73(7):522–527. doi: 10.1136/bjo.73.7.522. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Datiles M. B., Podgor M. J., Sperduto R. D., Kashima K., Edwards P., Hiller R. Measurement error in assessing the size of posterior subcapsular cataracts from retroillumination photographs. Invest Ophthalmol Vis Sci. 1989 Aug;30(8):1848–1854. [PubMed] [Google Scholar]
- Harris M. L., Hanna K. J., Shun-Shin G. A., Holden R., Brown N. A. Analysis of retro-illumination photographs for use in longitudinal studies of cataract. Eye (Lond) 1993;7(Pt 4):572–577. doi: 10.1038/eye.1993.124. [DOI] [PubMed] [Google Scholar]
- Kawara T., Obazawa H. A new method for retroillumination photography of cataractous lens opacities. Am J Ophthalmol. 1980 Aug;90(2):186–189. doi: 10.1016/s0002-9394(14)74852-4. [DOI] [PubMed] [Google Scholar]
- Khu P. M., Kashiwagi T. Subjective (LOCS II) versus objective (BGS) measures of cortical and subcapsular cataracts in retroillumination photographs. Ophthalmic Res. 1990;22 (Suppl 1):68–70. doi: 10.1159/000267068. [DOI] [PubMed] [Google Scholar]
- Magno B. V., Freidlin V., Datiles M. B., 3rd Reproducibility of the NEI Scheimpflug Cataract Imaging System. Invest Ophthalmol Vis Sci. 1994 Jun;35(7):3078–3084. [PubMed] [Google Scholar]
- Miyauchi A., Mukai S., Sakamoto Y. A new analysis method for cataractous images taken by retroillumination photography. Ophthalmic Res. 1990;22 (Suppl 1):74–77. doi: 10.1159/000267070. [DOI] [PubMed] [Google Scholar]
- Palta M., Cook T. Some considerations in the analysis of rates of change in longitudinal studies. Stat Med. 1987 Jul-Aug;6(5):599–611. doi: 10.1002/sim.4780060509. [DOI] [PubMed] [Google Scholar]
- Sasaki K., Sakamoto Y., Shibata T., Emori Y. The multi-purpose camera: a new anterior eye segment analysis system. Ophthalmic Res. 1990;22 (Suppl 1):3–8. doi: 10.1159/000267056. [DOI] [PubMed] [Google Scholar]
- Sparrow J. M., Brown N. A., Shun-Shin G. A., Bron A. J. The Oxford modular cataract image analysis system. Eye (Lond) 1990;4(Pt 4):638–648. doi: 10.1038/eye.1990.89. [DOI] [PubMed] [Google Scholar]