Reproducibility with the Keeler Pulsair 2000 non-contact tonometer.

S A Vernon 1
PMCID: PMC505164  PMID: 7626572

Abstract

AIMS--The IOP variation on repeated testing with the recently introduced Keeler Pulsair 2000 instrument was investigated. METHODS--One hundred normal individuals (50 male and 50 female) new to the instrument had three sets of IOP recordings within a 15 minute time period. RESULTS--The mean of the first set of IOPs from both right and left eyes was significantly higher than those from subsequent sets (p < 0.0001 for right eyes and p = 0.01 and < 0.0002 for left eyes). This tendency increased significantly with increasing IOP. Second and third IOP sets were, however, similar indicating stabilisation of IOP measurements. The coefficient of repeatability of the instrument between second and third sets was 4.2 mm Hg for right eyes and 3.6 mm Hg for left eyes. CONCLUSION--The Pulsair 2000 passes the British standard for reproducibility of a standard test method.

Full text

PDF
554

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
  2. Bonomi L., Baravelli S., Cobbe C., Tomazzoli L. Evaluation of Keeler Pulsair non-contact tonometry: reliability and reproducibility. Graefes Arch Clin Exp Ophthalmol. 1991;229(3):210–212. doi: 10.1007/BF00167869. [DOI] [PubMed] [Google Scholar]
  3. Fisher J. H., Watson P. G., Spaeth G. A new handheld air impulse tonometer. Eye (Lond) 1988;2(Pt 3):238–242. doi: 10.1038/eye.1988.48. [DOI] [PubMed] [Google Scholar]
  4. Forbes M., Pico G., Jr, Grolman B. A noncontact applanation tonometer. Description and clinical evaluation. Arch Ophthalmol. 1974 Feb;91(2):134–140. doi: 10.1001/archopht.1974.03900060140012. [DOI] [PubMed] [Google Scholar]
  5. Grolman B. A new tonometer system. Am J Optom Arch Am Acad Optom. 1972 Aug;49(8):646–660. doi: 10.1097/00006324-197208000-00005. [DOI] [PubMed] [Google Scholar]
  6. Moseley M. J., Evans N. M., Fielder A. R. Comparison of a new non-contact tonometer with Goldmann applanation. Eye (Lond) 1989;3(Pt 3):332–337. doi: 10.1038/eye.1989.48. [DOI] [PubMed] [Google Scholar]
  7. Moseley M. J., Thompson J. R., Deutsch J., Misson G. P., Naylor G., Tan-Yee A., Taylor R. H., Fielder A. R. Comparison of the Keeler Pulsair 2000 non-contact tonometer with Goldmann applanation. Eye (Lond) 1993;7(Pt 1):127–130. doi: 10.1038/eye.1993.26. [DOI] [PubMed] [Google Scholar]
  8. Myers K. J., Scott C. A. The non-contact ("air puff") tonometer: variability and corneal staining. Am J Optom Physiol Opt. 1975 Jan;52(1):36–46. [PubMed] [Google Scholar]
  9. Pearce C. D., Kohl P., Yolton R. L. Clinical evaluation of the Keeler PULSAIR 2000 tonometer. J Am Optom Assoc. 1992 Feb;63(2):106–110. [PubMed] [Google Scholar]
  10. Phelps C. D., Phelps G. K. Measurement of intraocular pressure: a study of its reproducibility. Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1976 Jan 16;198(1):39–43. doi: 10.1007/BF00411443. [DOI] [PubMed] [Google Scholar]
  11. Piltz J. R., Starita R., Miron M., Henkind P. Momentary fluctuations of intraocular pressure in normal and glaucomatous eyes. Am J Ophthalmol. 1985 Mar 15;99(3):333–339. doi: 10.1016/0002-9394(85)90365-4. [DOI] [PubMed] [Google Scholar]
  12. Sponsel W. E., Kaufman P. L., Strinden T. I., DePaul K. L., Bowes H. N., Olander K. W., Barnebey H. S. Evaluation of the Keeler Pulsair non-contact tonometer. Acta Ophthalmol (Copenh) 1989 Oct;67(5):567–572. doi: 10.1111/j.1755-3768.1989.tb04109.x. [DOI] [PubMed] [Google Scholar]
  13. Strong N. P. How optometrists screen for glaucoma: a survey. Ophthalmic Physiol Opt. 1992 Jan;12(1):3–7. [PubMed] [Google Scholar]
  14. Vernon S. A., Henry D. J. Do optometrists screen for glaucoma? Eye (Lond) 1989;3(Pt 6):743–746. doi: 10.1038/eye.1989.115. [DOI] [PubMed] [Google Scholar]
  15. Vernon S. A. Intra-eye pressure range and pulse profiles in normals with the Pulsair non-contact tonometer. Eye (Lond) 1993;7(Pt 1):134–137. doi: 10.1038/eye.1993.28. [DOI] [PubMed] [Google Scholar]
  16. Vernon S. A., Jones S. J. Intraocular pressure asymmetry in a population tested with the Pulsair non-contact tonometer. Eye (Lond) 1991;5(Pt 6):674–677. doi: 10.1038/eye.1991.124. [DOI] [PubMed] [Google Scholar]
  17. Vernon S. A. Non-contact tonometry in the postoperative eye. Br J Ophthalmol. 1989 Apr;73(4):247–249. doi: 10.1136/bjo.73.4.247. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Wilke K. Effects of repeated tonometry: genuine and sham measurements. Acta Ophthalmol (Copenh) 1972;50(4):574–582. doi: 10.1111/j.1755-3768.1972.tb05987.x. [DOI] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES