Abstract
AIMS: This study examined the occurrence, magnitude, and the consequences of a possible tilt between the corneal surface and optical axis of the EyeSys videokeratoscope. METHODS: Initially, a theoretical model was developed to calculate the angle of tilt. The predictions of the model were verified empirically using a convex conicoid surface and were found to predict the tilt to within 0.5 degree of the actual tilt. The likely effects of the tilt on the corneal power were also examined. The angle of tilt was then measured on the human cornea and the effect of neutralising the tilt on the videokeratoscopic data display was observed. RESULTS: The angle of tilt was found to lie between 1 degree and 6 degrees in a temporal direction. CONCLUSION: When the corneal tilt on the human subjects was neutralised, then a reduction in the nasal/temporal asymmetry was observed.
Full text
PDF







Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Antalis J. J., Lembach R. G., Carney L. G. A comparison of the TMS-1 and the corneal analysis system for the evaluation of abnormal corneas. CLAO J. 1993 Jan;19(1):58–63. doi: 10.1097/00140068-199301000-00011. [DOI] [PubMed] [Google Scholar]
- Burek H., Douthwaite W. A. Mathematical models of the general corneal surface. Ophthalmic Physiol Opt. 1993 Jan;13(1):68–72. doi: 10.1111/j.1475-1313.1993.tb00428.x. [DOI] [PubMed] [Google Scholar]
- Douthwaite W. A. Computerized contact lens fitting. Optom Vis Sci. 1991 Oct;68(10):770–775. doi: 10.1097/00006324-199110000-00002. [DOI] [PubMed] [Google Scholar]
- Douthwaite W. A. EyeSys corneal topography measurement applied to calibrated ellipsoidal convex surfaces. Br J Ophthalmol. 1995 Sep;79(9):797–801. doi: 10.1136/bjo.79.9.797. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Douthwaite W. A., Sheridan M. The measurement of the corneal ellipse for the contact lens practitioner. Ophthalmic Physiol Opt. 1989 Jul;9(3):239–242. doi: 10.1111/j.1475-1313.1989.tb00900.x. [DOI] [PubMed] [Google Scholar]
- Guillon M., Lydon D. P., Wilson C. Corneal topography: a clinical model. Ophthalmic Physiol Opt. 1986;6(1):47–56. [PubMed] [Google Scholar]
- Klein S. A., Mandell R. B. Shape and refractive powers in corneal topography. Invest Ophthalmol Vis Sci. 1995 Sep;36(10):2096–2109. [PubMed] [Google Scholar]
- Mandell R. B. Everett Kinsey Lecture. The enigma of the corneal contour. CLAO J. 1992 Oct;18(4):267–273. [PubMed] [Google Scholar]
- McCarey B. E., Zurawski C. A., O'Shea D. S. Practical aspects of a corneal topography system. CLAO J. 1992 Oct;18(4):248–254. [PubMed] [Google Scholar]
- Morrow G. L., Stein R. M. Evaluation of corneal topography: past, present and future trends. Can J Ophthalmol. 1992 Aug;27(5):213–225. [PubMed] [Google Scholar]
- Wilson S. E., Verity S. M., Conger D. L. Accuracy and precision of the corneal analysis system and the topographic modeling system. Cornea. 1992 Jan;11(1):28–35. doi: 10.1097/00003226-199201000-00004. [DOI] [PubMed] [Google Scholar]