Skip to main content
Data in Brief logoLink to Data in Brief
. 2016 Oct 3;9:563–567. doi: 10.1016/j.dib.2016.09.041

Data on consistency among different methods to assess atherosclerotic plaque echogenicity on standard ultrasound and intraplaque neovascularization on contrast-enhanced ultrasound imaging in human carotid artery

Mattia Cattaneo a,⁎,1, Daniel Staub b, Alessandra P Porretta a, Jeanne Marie Gallino a, Paolo Santini c, Costanzo Limoni d, Rolf Wyttenbach c,1, Augusto Gallino a,1
PMCID: PMC5061064  PMID: 27752526

Abstract

Here we provide the correlation among different carotid ultrasound (US) variables to assess echogenicity n standard carotid US and to assess intraplaque neovascularization on contrast enhanced US. We recruited 45 consecutive subjects with an asymptomatic≥50% carotid artery stenosis. Carotid plaque echogenicity at standard US was visually graded according to Gray–Weale classification (GW) and measured by the greyscale median (GSM), a semi-automated computerized measurement performed by Adobe Photoshop®. On CEUS imaging IPNV was graded according to the visual appearance of contrast within the plaque according to three different methods: CEUS_A (1=absent; 2=present); CEUS_B a three-point scale (increasing IPNV from 1 to 3); CEUS_C a four-point scale (increasing IPNV from 0 to 3). We have also implemented a new simple quantification method derived from region of interest (ROI) signal intensity ratio as assessed by QLAB software. Further information is available in “Contrast-enhanced ultrasound imaging of intraplaque neovascularization and its correlation to plaque echogenicity in human carotid arteries atherosclerosis (M. Cattaneo, D. Staub, A.P. Porretta, J.M. Gallino, P. Santini, C. Limoni et al., 2016) [1].

Keywords: Contrast enhanced ultrasound, Echogenicity, Carotid atherosclerosis


Specifications Table

Subject area Medicine
More specific subject area Peripheral artery imaging and atherosclerosis
Type of data Tables
How data was acquired Standard US ultrasound and contrast-enhanced ultrasound
Data format Analyzed
Experimental factors The data reports correlation coefficients and p-value between each plaque echogenicity variable and each contrast-enhanced ultrasound variable
Experimental features Carotid artery standard duplex ultrasound examination was performed to obtain images adequate for greyscale median measurement, performed offline. Then, contrast-enhanced ultrasound was performed according to subsequent visual and quantitative analysis.
Data source location Bellinzona − 6500, Switzerland
Data accessibility Data is within this article

Value of the data.

Consistency among results obtained by different methods to grade carotid plaque echogenicity and to visually assess the intraplaque neovascularization suggests that they may be interchangeable.

  • This may help to choose a visual method to assess IPNV by CEUS, since more reproducible methods may be preferred for future studies on carotid plaque.

  • This may also help to compare new quantitative methods to assess IPNV by CEUS (such as dynamic computer assisted analyses and 3D volume data sets), which are currently being developed.

  • Moreover, we provide here a new potentially useful, simple method for quantification of IPNV on US. However, it should be validated by histology.

1. Data

The data represented are provided in tables that display the correlation among different carotid ultrasound (US) variables.

  • 1.

    Correlation among echogenicity variables on standard carotid US as assess by the visual grading according Gray–Weale classification and measured by semi-automated according GSM-derived variables (assess by Adobe Photoshop®) (Table 1).

  • 2.

    Correlation among different visual methods to assess intraplaque neovascularization on contrast enhanced US and a new simple quantification method derived from region of interest (ROI)signal intensity ratio as assessed by QLAB software (Philips Healthcare NV, Amsterdam, The Nederlands) (Table 2).

Table 1.

Consistency among plaque echogenicity variables. Correlation coefficients and p-value are reported for each comparison. Level of significance p 0.01.

GW GSM GSM_mean pep_25 pep_32 percent_25 percent_75
CC (p-value) CC (p-value) CC (p-value) CC (p-value) CC (p-value) CC (p-value) CC (p-value)
GW 1.000
GSM −0.706 (0.000) 1.000
GSM_mean −0.724 (0.000) 0.952 (0.000) 1.000
pep_25 0.569 (0.000) −0.850 (0.000) −0.775 (0.000) 1.000
pep_32 0.593 (0.000) −0.907 (0.000) −0.831 (0.000) 0.983 (0.000) 1.000
percent_25 −0.579 (0.000) 0.901 (0.000) 0.818 (0.000) −0.960 (0.000) −0.974 (0.000) 1.000
percent_75 −0.684 (0.000) 0.934 (0.000) 0.965 (0.000) −0.701 (0.000) −0.767 (0.000) 0.747 (0.000) 1.000

Table 2.

Consistency among CEUS scores and quantification. Correlation coefficients and p-value are reported for each correlation. Level of significance p 0.01.

CEUS_A CEUS_B CEUS_C QLAB_ratio
CC (p-value) CC (p-value) CC (p-value) CC (p-value)
CEUS_A 1.000
CEUS_B 0.713 (.000) 1.000
CEUS_C 0.628 (.000) 0.841 (.000) 1.000
QLAB_ratio 0.124 (.452) −0.055 (.740) −0.073 (.657) 1.000

2. Experimental design, materials and methods

2.1. Study population

Patients were recruited from among consecutive subjects, who underwent carotid duplex ultrasound examinations. Inclusion and exclusion criteria have been previously published [1]. This is a sub-analysis of the same recruited patients (n=40), who have completed the US and CEUS examination. The study was approved by the local ethic review board and registered on clinicaltrial.gov (NCT02321410) [1].

2.2. US examination

The same experienced operator acquired all the extracranial cerebral arteries duplex ultrasound, by Philips iE33 xMatrix (Philips Healthcare NV, Amsterdam, The Nederlands) equipped with a 9 to 3 extended MHz linear array probes. The examination was implanted according to current guidelines as previously described [1].

2.2.1. Standard duplex ultrasound and GSM

Importantly, to obtain images adequate for greyscale median (GSM) measurement, US scanning set was optimized to visualize the media-adventitia interface at the far wall, but to avoid noise in the vessel lumen. These scanner sets permit to obtain similar average greyscale levels of the regions lying deeply and superficially from the scanner point of view, allowing subsequent image normalization and plaque analysis. Standard US images were normalized and GMS was calculated by Adobe Photoshop CS6 software (Adobe System, San Jose, CA, USA) as previously published [1]. The following parameters were calculated on the grey-scale image: median value (GSM), first percentile value (percent_25), third percentile value (percent_75), the percent of pixel with greyscale value under 25 (pep25) and 32 (pep32) [2], [3]. Each lesion echogenicity was also graded according to GW visual classification as follows [4]: uniformly echolucent (class I), predominantly echolucent (class II), predominantly echogenic (class III), or uniformly echogenic or extensively calcified (class IV).

2.2.2. Contrast enhanced Ultrasounds (CEUS)

CEUS was performed according to a previously described protocol [1], [5], [6] and following the US standard examination. The CEUS investigation focused on the single lesion per patient. US scanner settings used to acquire CEUS imaging has been previously published [1]. We performed CEUS imaging using sulphur hexafluoride-containing phospholipid microbubbles as a contrast agent (SonoVue; Bracco Spa, Milan, Italy) with a previously described protocol in order to minimize pseudo-enhancement artefacts [1]. A 30-second carotid CEUS loop-recording (CEUS-LR) was acquired and stored as DICOM image file for subsequent analysis. No adverse events occurred during the study.

2.3. CEUS grading

IPNV grading was performed according to the visual appearance of microspheres within the plaque profile as previously described in various studies [5], [6]. IPNV were identified by the dynamic movement of the echogenic reflectors (microspheres) observed within the hypoechoic plaque profile, which is in contrast with the highly-enhanced vessel lumen. We used three different visual methods to grade IPNV. Different working groups have previously published the following methods:

  • CEUS_A [6]: Grade 1=no appearance of bubbles within the plaque or bubbles confined to plaque adventitial side; Grade 2=appearance of bubbles within the plaque moving from the adventitial side or shoulder reaching plaque core.

  • CEUS_B [7]: Grade 1=no appearance of bubbles within the plaque; Grade 2=moderate appearance of bubbles within the plaque; Grade 3=extensive appearance of bubbles within the plaque.

  • CEUS_C [5]: Grade 0=no appearance of neovascularization within the plaque; Grade 1=limited appearance of neovascularization within the plaque; Grade 2=moderate neovascularization within the plaque; Grade 3=presence of a pulsating, arterial vessel within the plaque.

IPNV was also measured using QLAB image-manager software (Philips Healthcare NV, Amsterdam, The Nederland). IPNV was quantified by the QLAB-derived region of interest (ROI) ratio on a single frame (QLAB_ratio). From the dynamic CEUS-LR evaluation, each investigator independently chose a single still frame considered to be the most representative according to the highest amount of visually-detected microbubbles within the plaque. Two independent operators (MC and DS) drew two regions of interest on each selected frame. The first ROI (ROI1) was drawn to delineate the plaque by smooth polygon dragged clicking various points on the plaque contour, while the second ROI (ROI2) was drawn by a standard 5×5 mm square in the carotid lumen adjacent to the plaque in the same still frame. The software automatically calculates video intensity as decibel (dB) units on the still image. ROI-ratio was determined by ratio between RO1 and ROI2 intensity, so that the higher the ROI-ratio, the higher the estimated IPNV plaque burden. The present method has not been validated by means of histology.

3. Statistical methods

All statistical analyses were performed with IBM-SPSS software Version 22.0 (IBM Corporation, Software Group, Somers, NY, USA). Continuous data are shown as mean and SD, categorical data as numbers and proportions. Correlations were assessed using the non-parametric Spearman׳s Rho correlation coefficient and the χ-square test. Statistical significance was declared if the rounded two-tailed p-value will be less than 0.05.

Acknowledgements

None

Footnotes

Transparency document

Transparency data associated with this article can be found in the online version at http://dx.doi. org/10.1016/j.dib.2016.09.041.

Transparency document. Supplementary material

Supplementary material

mmc1.pdf (1.2MB, pdf)

References

  • 1.Cattaneo M., Staub D., Porretta A.P., Gallino J.M., Santini P., Limoni C. Contrast-enhanced ultrasound imaging of intraplaque neovascularization and its correlation to plaque echogenicity in human carotid arteries atherosclerosis. Int. J. Cardiol. 2016;223:917–922. doi: 10.1016/j.ijcard.2016.08.261. [DOI] [PubMed] [Google Scholar]
  • 2.El-Barghouty N.M., Levine T., Ladva S., Flanagan A., Nicolaides A. Histological verification of computerised carotid plaque characterisation. Eur. J. Vasc. Endovasc. Surg. 1996;11(4):414–416. doi: 10.1016/s1078-5884(96)80172-9. [DOI] [PubMed] [Google Scholar]
  • 3.Biasi G.M., Froio A., Diethrich E.B., Deleo G., Galimberti S., Mingazzini P. Carotid plaque echolucency increases the risk of stroke in carotid stenting: the imaging in carotid angioplasty and risk of stroke (ICAROS) study. Circulation. 2004;110(6):756–762. doi: 10.1161/01.CIR.0000138103.91187.E3. [DOI] [PubMed] [Google Scholar]
  • 4.Gray-Weale A.C., Graham J.C., Burnett J.R., Byrne K., Lusby R.J. Carotid artery atheroma: comparison of preoperative B-mode ultrasound appearance with carotid endarterectomy specimen pathology. J. Cardiovasc. Surg. (Torino) 1988;29(6):676–681. [PubMed] [Google Scholar]
  • 5.Shah F., Balan P., Weinberg M., Reddy V., Neems R., Feinstein M. Contrast-enhanced ultrasound imaging of atherosclerotic carotid plaque neovascularization: a new surrogate marker of atherosclerosis? Vasc. Med. 2007;12(4):291–297. doi: 10.1177/1358863X07083363. [DOI] [PubMed] [Google Scholar]
  • 6.Staub D., Patel M.B., Tibrewala A., Ludden D., Johnson M., Espinosa P. Vasa vasorum and plaque neovascularization on contrast-enhanced carotid ultrasound imaging correlates with cardiovascular disease and past cardiovascular events. Stroke. 2010;41(1):41–47. doi: 10.1161/STROKEAHA.109.560342. [DOI] [PubMed] [Google Scholar]
  • 7.Staub D., Partovi S., Schinkel A.F., Coll B., Uthoff H., Aschwanden M. Correlation of carotid artery atherosclerotic lesion echogenicity and severity at standard US with intraplaque neovascularization detected at contrast-enhanced US. Radiology. 2011;258(2):618–626. doi: 10.1148/radiol.10101008. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary material

mmc1.pdf (1.2MB, pdf)

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES