Skip to main content
Molecular and Clinical Oncology logoLink to Molecular and Clinical Oncology
. 2016 Aug 24;5(5):625–630. doi: 10.3892/mco.2016.1003

Avoidance of unnecessary fine-needle aspiration with the use of the Thyroid Imaging Reporting Data System classification and strain elastography based on The Bethesda System for Reporting Thyroid Cytopathology

Murat Erkan 1, Sule Canberk 1,4,, Gamze Z Kilicoglu 2, Mine Onenerk 1, Atay Uludokumaci 3, Pembegul Gunes 1, Tugba Atasoy 2
PMCID: PMC5103887  PMID: 27900100

Abstract

Thyroid fine-needle aspiration (FNA) biopsy has been widely accepted as an accurate and cost-effective tool in the management of thyroid nodules. To avoid unnecessary FNAs and provide appropriate management, patient evaluation should be based on a multidisciplinary approach. For this purpose, the Thyroid Imaging Reporting and Data System (TI-RADS) and strain elastography (SE) were proposed as tools for the risk assessment of malignancy in thyroid nodules. The aim of the present study was to analyze the utility of TI-RADS system and SE, along with FNA, and prospectively evaluate 369 consecutive patients referred for FNA of a thyroid nodule. TI-RADS was tested against The Bethesda System for Reporting Thyroid Cytopathology to determine whether there was an agreement between the two classification systems; statistically, some agreement was observed. Medians of the maximum SE values (E-max) were obtained for benign and malignant FNA results and found to be 1.97 [interquartile range (IQR): 1.87] and 2.8 (IQR: 3.42), respectively (P=0.004). The number of studies investigating the utility of TI-RADS and SE along with TBSRCT is currently limited. Our study demonstrated that a multidisciplinary approach with the use of TI-RADS and SE may mildly improve the management of thyroid nodules.

Keywords: thyroid fine-needle aspiration, Bethesda, Thyroid Imaging Reporting and Data System, elastography

Introduction

The incidence of thyroid nodules has significantly increased over the last decades (1). Thyroid nodules may be detected in 19–67% of the cases by high-resolution ultrasound, and thyroid cancer must be excluded in all these nodules (2). Thyroid nodules are mostly benign and asymptomatic and, thus, do not require any treatment. Fine-needle aspiration (FNA) has become an essential diagnostic modality in the evaluation of thyroid nodules and is implicated in all three major guidelines in patient management, namely the American Thyroid Association (ATA), the European Thyroid Association (ETA) and the Society of Radiologists in Ultrasound (SRU) (3); however, there is currently no consensus regarding the exact indications of FNA in these three main guidelines. The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), which was created through multidisciplinary formulation, is the most popular cytology reporting system worldwide (4).

The primary success of TBSRTC was reducing unnecessary thyroid surgery. The malignancy detection rate increased from 14 to 50% prior to and following adoption of FNA as a diagnostic modality, respectively, and was even higher after the introduction of TBSRTC (5). However, the effectiveness of TBSRTC in reducing unnecessary and repeat FNAs, which was the secondary aim, appears to be limited. TBSRTC appears to lack solid support by the main guidelines due to the lack of standardization and clear-cut indications of FNA (3,6). US scoring systems have been devised in an attempt to overcome this weakness. Despite its high diagnostic ability and cost-effectiveness, TBSRTC may be becoming a screening test, which may be associated with high cost rates due to the significant number of FNAs performed in daily routine practice; moreover, it may increase false-positive results in cytological specimens and false-negative/vanishing tumor diagnosis in pathological specimens (6,7).

A number of different imaging modalities have been used to evaluate thyroid nodules to avoid unnecessary FNA and surgery. The Thyroid Imaging Reporting and Data System (TI-RADS) was introduced in 2009 by Horvath et al (8), based on the concepts of the Breast Imaging Reporting and Data System, which conducts a risk assessment of malignancy in breast FNAs. Horvath et al proposed 10 characteristics, and Park et al (9) subsequently established a new system with 12 characteristics, which were aimed at standardizing the evaluation of thyroid nodules with US. However, the application of those characteristics to all thyroid nodules was found to be problematic.

Sonoelastography, first proposed in 1991 by Ophir et al, operates on the relative hardness of the nodule compared with the adjacent thyroid parenchyma to improve diagnostic accuracy (7,10). There are two technically different methods, both aimed at measuring the stiffness of the tissues: Strain and shear-wave elastography. Strain elastography (SE) consists of a quantitative measure (strain index) and a qualitative color picture superimposed on the B-mode image. The proof of elevated/increased stiffness should guide FNA, even in nodules without suspicious findings on ultrasound (11).

Therefore, the main question is which nodules should be referred for FNA, which was addressed by investigating 369 cases using TI-RADS and SE with TBSRTC.

Materials and methods

Case selection

The study was designed to include prospective FNA diagnostics in patients with nodules/focal lesions of the thyroid gland, who were referred for biopsy to the Haydarpasa Numune Training and Research Hospital (Istanbul, Turkey) between January and June, 2014. All aspects of the study were reviewed and approved by the hospital's Institutional Review Board. A total of 369 cases were evaluated by 3 radiologists (with 17, 2 and 16 years of experience) and FNAs were performed. Using the recorded images, a single radiologist determined the corresponding TI-RADS category (Horvath) (Table I).

Table I.

US patterns in each TI-RADS (Horvath) category and clinical recommendations based on these categories.

Description of US pattern US patterns Malignancy TI-RADS Recommendation
Echoic with hyperechoic spots, non-vascularized lesion Colloid type 1   0% TI-RADS 2: Benign findings Follow-up without FNA
Non-encapsulated, mixed, non- expansile, with hyperechoic spots, vascularized lesion, grid aspect (spongiform nodule) Colloid type 2
Non-encapsulated, mixed with solid portion, isoechogenic, expansile, vascularized nodule with hyperechoic spots Colloid type 3
Hyper-, iso-, or hypoechoic, partially encapsulated nodule with peripheral vascularization, in Hashimoto's thyroiditis Hashimoto pseudonodule   <5% TI-RADS 3: Likely benign Follow-up, FNA may be performed according to clinical suspicion
Solid or mixed hyper-, iso-, or hypoechoic nodule, with a thin capsule Simple neoplastic pattern   5–10% TI-RADS 4A: Undetermined FNA
Hypoechoic lesion with ill-defined borders, without calcifications de Quervain pattern
Hyper-, iso-, or hypoechoic, hypervascularized, encapsulated nodule with a thick capsule, containing calcifications (coarse or microcalcifications) Suspicious neoplastic pattern
Hypoechoic, non-encapsulated nodule, with irregular shape and margins, penetrating vessels, with or without calcifications Malignant pattern A 10–80% TI-RADS 4B: Suspicious FNA
Iso- or hypoechoic, non-encapsulated nodule with multiple peripheral microcalcifications and hypervascularization Malignant pattern B   >80% TI-RADS 5: Consistent with malignancy FNA
Non-encapsulated, isoechoic, mixed hypervascularized nodule with or without calcifications, without hyperechoic spots Malignant pattern C cancer, confirmed by previous biopsy   100% TI-RADS 6: Malignant

US, ultrasonography; TI-RADS, Thyroid Imaging Reporting and Data System; FNA, fine-needle aspiration.

Procedures

All the patients were ultrasonographically examined (iU22 ultrasound device; Philips, Bothell, WA, USA), elastography was performed and the strain ratio was recorded. Heterogeneous thyroid parenchyma, substernal elongation of the nodule or recurrent nodules following partial/total thyroidectomy hinder elastographic measurement due to the lack of proper reference/background tissue and a maximum SE value (E-max) could not be provided for these cases.

FNAs were performed with a 22-gauge needle and two smears were prepared for each pass. Rapid on-site evaluation was performed by a cytopathologist using Diff-Quik stain. Cell blocks were prepared from the excess material in the syringe. All the cases were signed by the same cytopathologist according to TBRSTC.

Statistical analysis

Statistical analysis was performed using the SPSS software, version 20 (IBM SPSS, Armonk, NY, USA). The variables were investigated using visual or analytical methods to determine whether they were normally distributed. As the E-max value was not normally distributed, the Mann-Whitney U test was conducted to compare values among TBSRTC categories. The agreement between TI-RADS and TBSRTC was tested by using Cohen's Kappa statistics. An overall 5% type-1 error level was used to infer statistical significance.

Results

Patient characteristics

A total number of 369 thyroid FNA cases performed between January and June, 2014 were included in the present study. The majority (86.7%; n=320) of the patients were female and the mean age of the patients ± standard deviation was 56.9±11 years. According to TBSRTC, 17.1% (n=63), 59.3% (n=219), 7.1% (n=26), 5.1% (n=19), 2.7% (n=10) and 8.7% (n=32) of the cases were reported as non-diagnostic (ND), benign (B), atypia of undetermined significance/follicular lesion of unknown significance, follicular neoplasia/suspicious for follicular neoplasia, suspicious for malignancy (SFM) and malignant (M), respectively. The same cases were evaluated as category 2 (39%; n=144), category 3 (4.1%; n=15), category 4 (45%; n=166) and category 5 (1.6%; n=6) according to TI-RADS (Table II). A total of 13.8% (n=51) of the patients underwent consequent thyroidectomy, and the subsequent histopathological diagnosis was benign in 39.2% (n=20) and malignant in 70.8% (n=31) of the cases. Malignant diagnosis included 30 papillary thyroid carcinomas (6 classic, 4 encapsulated follicular, 4 aggressive, 7 follicular, 8 oncocytic and 1 Warthin-like variants) and 1 medullary thyroid carcinoma. There was no discrepancy between cytopathological and histopathological diagnosis. The distribution of the cases according to TBRSCT in each TI-RADS category is summarized in Table III. There was some agreement between the TI-RADS and TBRSCT classification systems (32.5%) and the kappa value for benign and malignant diagnosis was 0.1. In 16% (n=59) of the cases, E-max value could not be provided due to the lack of normal thyroid parenchyma due to multinodular goiter and chronic lymphocytic thyroiditis. For the evaluated cases, the median E-max value for benign nodules was 1.97 [interquartile range (IQR): 1.87], whereas in SFM and M nodules it was 2.8 (IQR: 3.42), and the difference was found to be statistically significant (P=0.004; Fig. 1).

Table II.

Patient characteristics.

Characteristics No. (%)
Gender
  Female 320 (86.7)
  Male 49 (13.3)
Age, years
  Mean (range) 56.9 (40–62)
Lobe
  Right 182 (49.3)
  Left 170 (46.0)
  Isthmus 17 (4.7)
Nodule size, mm
  Mean (range) 17.9 (4–50)
% of cases in TI-RADS categories
  2 144 (39.0)
  3 15 (4.1)
  4a 166 (45.0)
  4b 38 (10.3)
  5 6 (1.6)
  Total 369 (100.0)
% of cases in TBSRTC categories
  ND 63 (17.1)
  B 219 (59.3)
  AUS/FLUS 26 (7.1)
  FN/SFN 19 (5.1)
  SFM 10 (2.7)
  M 32 (8.7)
  Total 369 (100.0)

TI-RADS, Thyroid Imaging Reporting and Data System; TBRSCT, The Bethesda System for Reporting Thyroid Cytopathology; ND, non-diagnostic; B, benign; AUS/FLUS, atypia/follicular lesion of undetermined singnificance; FN/SFN, follicular neoplasia/suspicious for follicular neoplasia; SFM, suspicious for malignancy; M, malignant.

Table III.

Distribution of cases between TI-RADS and TBSRTC.

TBCSRTC No. of cases in each category (%) Malignancy ratio according to Horvath et al (8)
TI-RADS 2   0%
  ND 21 (14.5)
  B 105 (73.0)
  AUS/FLUS/FN/SFN 10 (7.0)
  SFM/M 8 (5.5)
TI-RADS 3   <5%
  ND 3 (20.0)
  B 9 (60.0)
  AUS/FLUS/FN/SFN 2 (13.3)
  SFM/M 1 (6.7)
TI-RADS 4a   5–10%
  ND 33 (19.9)
  B 91 (54.8)
  AUS/FLUS/FN/SFN 25 (15.1)
  SFM/M 17 (10.2)
TI-RADS 4b 10–80%
  ND 5 (13.1)
  B 15 (39.5)
  AUS/FLUS/FN/SFN 8 (21.0)
  SFM/M 10 (26.4)
TI-RADS 5   >80%
  ND 1 (16.6)
  B 0 (0.0)
  AUS/FLUS/FN/SFN 0 (0.0)
  SFM/M 5 (83.4)

TI-RADS, Thyroid Imaging Reporting and Data System; TBRSCT, The Bethesda System for Reporting Thyroid Cytopathology; ND, non-diagnostic; B, benign; AUS/FLUS, atypia/follicular lesion of undetermined singnificance; FN/SFN, follicular neoplasia/suspicious for follicular neoplasia; SFM, suspicious for malignancy; M, malignant.

Figure 1.

Figure 1.

Box plot shows E-max values of 261 benign and malignant (SFM/M) cases. x-axis and y-axis demonstrate benign and malignant cases according to TBSRTC and E-max values, respectively. The lower and upper ends of vertical lines are minimum and maximum E-max values. The upper edge of both boxes are the 75th percentile of the data set; lower end represents the 25th percentile. The line in the box shows the median.

Discussion

Walfish et al (12) first proposed ultrasonography (US)-guided FNA in 1977; since then, US-guided FNA has significantly accelerated daily practice. The following US characteristics are widely used to highlight the risk of malignancy in thyroid nodules: Vascularity, microcalcifications, composition, echogenity, margins, presence of a peripheral halo and calcifications. There has been a general consensus/agreement in ATA, ETA or SRU, that suspicious US characteristics are an indication for FNA (2,6,13,14). However, those guidelines have various combinations of suggestions in evaluating malignancy of thyroid nodules that may cause confusion between clinicians. Recently, to establish a better communication between radiologists and clinicians, several US proposals and/or scoring systems have been proposed in the literature (9,15).

TI-RADS was introduced by Horvath et al in 2009 to create a standardized reporting system, inspired by BIRADS, based on the malignancy risk assessment of thyroid nodules (8). At the beginning, TI-RADS appeared to be promising through focusing not only on benign nodules, but also on follicular lesions. The main disadvantages of TI-RADS were difficulty in evaluating 10 US parameters for every nodule, and its complexity that does not provide a clear discrimination for the malignancy risk assessment, let alone focusing on follicular lesions. Over time, TI-RADS was modified by a number of authors in several studies. Park et al proposed a new system based on 12 US characteristics (9). Another modified TI-RADS was introduced by Kwak et al (15), which appeared to have a more practical basis on 5 US characteristics compared with the previous versions.

The present study was designed to compare the compatibility and feasibility of the Horvath TI-RADS with TBSRTC and its usefulness for avoiding unnecessary FNAs with the contribution of elastography. Kwak et al reported the increased malignancy risk in correlation with an increased number of suspicious US characteristics (15). Friedrich-Rust et al (16) reported promising results in terms of interobserver agreement with 3 observers for 114 thyroid nodules, but still point out the need for further studies to create an optimal system integrating all TI-RADS categories. The negative predictive value (NPV) was 92–100% for TI-RADS categories 4 and 5 in the diagnosis of malignancy in the same study.

Our study also demonstrated some agreement between every category of the TI-RADS system and TBSRTC. The suggested malignancy risks were 5–10% and 10–80% in categories 4a and 4b of Horvath TI-RADS, respectively, which were compatible with our results in TI-RADS 4a and 4b (10.2–26%). Our malignancy ratio in TI-RADS 2 was 5.5% while Horvath's was 0%. Compared with other modified TI-RADS, Horvath's proposal appears to be quite strict (8,9,15) Hence, further large-scale studies are required on this topic. ND and benign cytology results represented marked cumulation in the TI-RADS 4a group that may have originated from external and internal changes of the nodule: Recently, Eze et al stated the importance of FNA-induced changes that may give rise to false-positive results on thyroid cytology and false-negative results/understaging of the tumor on thyroid pathology (17). Unnecessary and repeat FNAs may cause what is referred to as ‘external factors/changes’, causing degenerative processes in the nodule through organizing hemorrhage, granulation tissue, fibrosis and sclerosis. The same cellular processes may be seen as spontaneous degenerative changes of the nodule, referred to as ‘internal factors/changes’ (18). All these external and internal changes of the nodule may resemble suspicious imaging findings that may easily be categorized as TI-RADS 4a (19). Overlapping US characteristics of malignant and benign nodules is an ongoing problem, despite several large-scale studies that were successful in discriminating malignancy in thyroid nodules. The results of internal and external changes of the nodule may be reflected as false-positive results in cytopathology and vanishing tumors/understaging of the tumor in pathology (17,18). The amount of unnecessary FNAs has been steadily increasing due to the increased detection of nodules by high resolution US. This may lead to transforming a successful diagnostic test into a screening modality, which may have legal implications and is associated with high medical costs (7). Our results demonstrated that TI-RADS 4a must be elucidated to eliminate the overlapping characteristics of reactive changes and malignancy in this group.

Elastography has been proposed as a new dynamic technique to assess the elasticity of the nodule in comparison with the adjacent parenchyma and is a well-accepted method for the breast and prostate gland. Previously published studies suggest certain limitations based on technical and histological factors (7) (Table IV). However, several studies demonstrated the usefulness of SE in avoiding unnecessary FNA and discriminating malignant from benign nodules. The sensitivity and specificity vary from 43.2–100% up to 70–92%, respectively, along with wide alterations of the positive predictive value (40–60%); however, the most common point is the high NPV results (90–99%) in almost all studies (2023). Despite all its limitations, we consider SE to be a reliable method in the diagnosis of benign nodules, taking into consideration the high NPV ratios in the majority of the studies.

Table IV.

Limitations of strain elastography.

Technical Histological
Intra-/interobserver variability Thyroiditis
Lack of standardization Calcification
Clinical conditions of the patient: Cystic degeneration
Arrhytmia, aterosclerosis, hypertension
Carotid artery pulsations Isthmic localization
Nodule size
Follicular carcinoma (due to the softness of the tumor)

Although our results were presented as a scheme (Fig. 2), we do not propose an algorithm for patient management, since a group of 369 patients is not sufficiently large to suggest one. There is some agreement between TI-RADS and TBSRTC, but the high ratio of benign cytology results in categories 4a (54.8%) and 4b (39.5%) demonstrate that benign characteristics actually dominate these groups and, thus, the unnecessary biopsy rate is increased, disguising malignancy. These categories require modifications. Further studies should be performed concerning inter- and intraobserver variability, internal and external histological factors, or different imaging methods. A similar contradiction exists for ES. The E-max values demonstrate a marginally significant difference between benign and malignant nodules; however, the significant overlap over a wide range of values limit its use in daily practice.

Figure 2.

Figure 2.

Process flowchart. TI-RADS, Thyroid Imaging Reporting and Data System; FNA, fine-needle aspiration.

We believe that TI-RADS, as well as E-max, may be considered for inclusion in the 3 main guidelines; however, due to the abovementioned limitations, they must be simplified/modified. TBSRTC must have a simple, reproducible US scoring system to prevent unnecessary FNAs, which may be added to the main guidelines if it proves to be a secondary success over time.

In conclusion, TI-RADS must be modified, or a new US uniform reporting system must be created in a significantly more practical and effective manner. The TI-RADS categories and SE must be reviewed to eliminate the significant existing overlap between benign and malignant cytology findings. The high rate of unnecessary biopsy for benign thyroid nodules is a worldwide problem; thus, our results demonstrate a certain benefit in discrimination compared with the current system.

References

  • 1.Faquin WC, Bongiovanni M, Sadow PM. Update in thyroid fine needle aspiration. Endocr Pathol. 2011;22:178–183. doi: 10.1007/s12022-011-9182-7. [DOI] [PubMed] [Google Scholar]
  • 2.American Thyroid Association (ATA) Guidelines Taskforce on Thyroid Nodules and Differentiated Thyroid Cancer, corp-author. Cooper DS, Doherty GM, Haugen BR, Kloos RT, Lee SL, Mandel SJ, Mazzaferri EL, McIver B, Pacini F, et al. Revised American thyroid association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid. 2009;19:1167–1214. doi: 10.1089/thy.2009.0110. [DOI] [PubMed] [Google Scholar]
  • 3.Ahn SS, Kim EK, Kang DR, Lim SK, Kwak JY, Kim MJ. Biopsy of thyroid nodules: Comparison of three sets of guidelines. AJR Am J Roentgenol. 2010;194:31–37. doi: 10.2214/AJR.09.2822. [DOI] [PubMed] [Google Scholar]
  • 4.Cibas ES, Ali SZ. The Bethesda system for reporting thyroid cytopathology. Thyroid. 2009;19:1159–1165. doi: 10.1089/thy.2009.0274. [DOI] [PubMed] [Google Scholar]
  • 5.Moon HJ, Kim EK, Yoon JH, Kwak JY. Malignancy risk stratification in thyroid nodules with nondiagnostic results at cytologic examination: Combination of thyroid imaging reporting and data system and the Bethesda System. Radiology. 2015;274:287–295. doi: 10.1148/radiol.14140359. [DOI] [PubMed] [Google Scholar]
  • 6.Dhyani M, Faquin W, Lubitz CC, Daniels GH, Samir AE. How to interpret thyroid fine-needle aspiration biopsy reports: A guide for the busy radiologist in the era of the Bethesda classification system. AJR Am J Roentgenol. 2013;201:1335–1339. doi: 10.2214/AJR.13.10537. [DOI] [PubMed] [Google Scholar]
  • 7.Cantisani V, Grazhdani H, Drakonaki E, D'Andrea V, Di Segni M, Kaleshi E, Calliada F, Catalano C, Redler A, Brunese L, et al. Strain US elastography for the characterization of thyroid nodules: Advantages and limitation. Int J Endocrinol. 2015;2015:908575. doi: 10.1155/2015/908575. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Horvath E, Majlis S, Rossi R, Franco C, Niedmann JP, Castro A, Dominguez M. An ultrasonogram reporting system for thyroid nodules stratifying cancer risk for clinical management. J Clin Endocrinol Metab. 2009;94:1748–1751. doi: 10.1210/jc.2008-1724. [DOI] [PubMed] [Google Scholar]
  • 9.Park JY, Lee HJ, Jang HW, Kim HK, Yi JH, Lee W, Kim SH. A proposal for a thyroid imaging reporting and data system for ultrasound features of thyroid carcinoma. Thyroid. 2009;19:1257–1264. doi: 10.1089/thy.2008.0021. [DOI] [PubMed] [Google Scholar]
  • 10.Ophir J, Céspedes I, Ponnekanti H, Yazdi Y, Li X. Elastography: A quantitative method for imaging the elasticity of biological tissues. Ultrasoun Imaging. 1991;13:111–134. doi: 10.1016/0161-7346(91)90079-W. [DOI] [PubMed] [Google Scholar]
  • 11.Kwak JY, Kim EK. Ultrasound elastography for thyroid nodules: Recent advances. Ultrasonography. 2014;33:75–82. doi: 10.14366/usg.13025. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Walfish PG, Miskin M, Rosen IB, Strawbridge HT. Application of diagnostic techniques in the management of nodular goiter. Can Med Assoc J. 1976;115:35–40. [PMC free article] [PubMed] [Google Scholar]
  • 13.Gharib H, Papini E, Paschke R, Duick DS, Valcavi R, Hegedüs L, Vitti P. AACE/AME/ETA Task Force on Thyroid Nodules: American Association of Clinical Endocrinologists, Associazione Medici Endocrinologi and European thyroid association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules: Executive summary of recommendations. J Endocrinol Invest. 2010;33:287–291. doi: 10.1007/BF03346587. [DOI] [PubMed] [Google Scholar]
  • 14.Frates MC, Benson CB, Charboneau JW, Cibas ES, Clark OH, Coleman BG, Cronan JJ, Doubilet PM, Evans DB, Goellner JR, et al. Management of thyroid nodules detected at US: Society of radiologists in ultrasound consensus conference statement. Ultrasound Q. 2006;22:231–238. doi: 10.1097/01.ruq.0000226877.19937.a1. discussion 239–240. [DOI] [PubMed] [Google Scholar]
  • 15.Kwak JY, Han KH, Yoon JH, Moon HJ, Son EJ, Park SH, Jung HK, Choi JS, Kim BM, Kim EK. Thyroid imaging reporting and data system for US features of nodules: A step in establishing better stratification of cancer risk. Radiology. 2011;260:892–899. doi: 10.1148/radiol.11110206. [DOI] [PubMed] [Google Scholar]
  • 16.Friedrich-Rust M, Meyer G, Dauth N, Berner C, Bogdanou D, Herrmann E, Zeuzem S, Bojunga J. Interobserver agreement of Thyroid Imaging Reporting and Data System (TI-RADS) and strain elastography for the assessment of thyroid nodules. PLoS One. 2013;8:e77927. doi: 10.1371/journal.pone.0077927. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Eze OP, Cai G, Baloch ZW, Khan A, Virk R, Hammers LW, Udelsman R, Roman SA, Sosa JA, Carling T, et al. Vanishing thyroid tumors: A diagnostic dilemma after ultrasonography-guided fine-needle aspiration. Thyroid. 2013;23:194–200. doi: 10.1089/thy.2012.0157. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Canberk Ş, Firat P, Schmitt F. Pitfalls in the cytological assessment of thyroid nodules. Turk Patoloji Derg. 2015;31:S18–S33. doi: 10.5146/tjpath.2015.01312. (Suppl 1) [DOI] [PubMed] [Google Scholar]
  • 19.Lacout A, Thariat J, Chevenet C, Marcy PY. Management of thyroid nodules on US with benign or atypical cytological features. Diagn Interv Imaging. 2015;96:507–509. doi: 10.1016/j.diii.2014.10.007. [DOI] [PubMed] [Google Scholar]
  • 20.Nell S, Kist JW, Debray TP, de Keizer B, van Oostenbrugge TJ, Borel Rinkes IH, Valk GD, Vriens MR. Qualitative elastography can replace thyroid nodule fine-needle aspiration in patients with soft thyroid nodules. A systematic review and meta-analysis. Eur J Radiol. 2015;84:652–661. doi: 10.1016/j.ejrad.2015.01.003. [DOI] [PubMed] [Google Scholar]
  • 21.Guazzaroni M, Spinelli A, Coco I, Del Giudice C, Girardi V, Simonetti G. Value of strain-ratio on thyroid real-time sonoelastography. Radiol Med. 2014;119:149–155. doi: 10.1007/s11547-013-0320-9. [DOI] [PubMed] [Google Scholar]
  • 22.Refaat R, Kamel A, Elganzory M, Awad NM. Can real-time ultrasound elastography using the color score and strain ratio differentiate between benign and malignant solitary nodules? The Egyptian Society of Radiology and Nuclear Medicine. 2014;45:75–87. doi: 10.1016/j.ejrnm.2013.12.005. [DOI] [Google Scholar]
  • 23.Wang H, Zhang S, Xin X, Zhao LH, Li CX, Mu JL, Wei XQ. Application of real-time ultrasound elastography in diagnosing benign and malignant thyroid solid nodules. Cancer Biol Med. 2012;9:124–127. doi: 10.3969/j.issn.2095-3941.2012.02.008. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Molecular and Clinical Oncology are provided here courtesy of Spandidos Publications

RESOURCES