Abstract
Background
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emergency procedure to manage severe hemorrhagic shock from torso injury but can cause severe ischemia of the lower extremities. However, lower extremity ischemia occurring as a complication of REBOA has been rarely reported. We describe the severe lower extremity ischemia caused by REBOA with a 12-Fr sheath in a small-built patient.
Case representation
The patient was a 16-year-old male who developed severe hemorrhagic shock due to abdominal blunt trauma. Following REBOA with a 12-Fr sheath on the right femoral artery, an emergency laparotomy and angiography to control the hemorrhage were performed. Twenty-eight hours after admission, suspecting lower extremity ischemia and compartment syndrome, we removed the sheath with a manual maneuver and performed fasciotomy. The limb ischemia was thus partially resolved. However, amputation was necessary because of ischemic necrosis on day 32. Our patient was physically small, and the diameter of his femoral artery on the contralateral site of sheath placement was also small. Therefore, disproportion of the sheath and femoral artery sizes may have caused the ischemic complication.
Conclusion
Our experience highlights the importance of appropriate size selection for the sheath in line with the target vessel. We also recommend postoperative monitoring of limb perfusion in such cases with the use of near-infrared spectroscopy to facilitate the early detection of ischemia.
Keywords: Balloon occlusion, Hemorrhagic shock, Ischemia, Near-infrared spectroscopy, Blunt abdominal injury, IABO, REBOA, Sheath, Femoral artery
Background
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emergency procedure for the management of severe hemorrhagic shock caused by torso injury. This intervention can cause severe ischemia of the lower extremities [1]. However, ischemic complication of the lower extremities after REBOA has been rarely reported. We describe the severe lower extremity ischemia directly attributable to REBOA.
Case presentation
A previously healthy 16-year-old male with blunt abdominal injury sustained in a road traffic accident was referred to our department. On arrival, he was in severe hemorrhagic shock, and his vital signs were as follows: heart rate 160 bpm, blood pressure unmeasurable, respiratory rate 27/min, and Glasgow Coma Scale E3V4M6. His chest X-ray revealed no apparent hemothorax and pneumothorax, and pelvic X-ray revealed no unstable fracture of the pelvic ring. Focused assessment with sonography for trauma was positive; thus, we suspected intra-abdominal hemorrhage. The arterial blood gas assessment showed metabolic acidosis, and the laboratory test on admission revealed coagulopathy (Table 1). The fluid resuscitation (crystalloid 1000 ml bolus infusion) improved his blood pressure to 71/37 mmHg. REBOA was placed with a 12-Fr sheath on the right femoral artery by the Seldinger method without sonography 10 min after admission, and the balloon placement at zone 1 was confirmed by chest X-ray. The patient was prepared for an emergency laparotomy 25 min after admission. During the surgery, we found splenic rupture, stomach perforation, hepatic injury, rectal and omental injury, and splenectomy; temporary repair of the injury, gauze packing, and vacuum packing closure were performed as damage control measures (operation time 65 min, intraoperative blood loss 2470 g). REBOA was performed for 25 min with total occlusion and deflated after the control of major bleeding. Postoperative enhanced computed tomography (CT) revealed extravasation from the left kidney and posterior segment of the liver. Thus, we performed angiography for embolization. After admission to the intensive care unit, coagulopathy and hypothermia were corrected with massive blood transfusion; however, his vital signs continued to remain unstable. A chest drainage tube was inserted for left hemothorax removal. Due to increased amount of blood discharge from the chest, we performed exploratory thoracotomy and re-laparotomy. During the second surgery, the blood leakage was found to originate from the hepatic injury and passed through the diaphragmatic injury into the thoracic cavity; we then arrested the bleeding. Fourteen hours after admission, the patient became stable. However, we retained the sheath for a potential repeat of REBOA in the event of re-bleeding. Twenty-eight hours after admission, swelling and paleness were observed in his right lower leg (Fig. 1a). Suspecting lower extremity ischemia and compartment syndrome, we removed the sheath with a manual maneuver and performed fasciotomy for the lower leg (Fig. 1b). The color of the right lower limb was thus partially resolved, and we guessed the ischemic change was improved. However, amputation was necessary because of ischemic necrosis on day 32. On day 81, he was transferred to a community hospital for rehabilitation.
Table 1.
CBC | |
WBC | 9200/μl |
RBC | 297 × 104/μl |
Hb | 8.8 g/dl |
Ht | 25.2% |
Plt | 14.9 × 104/μl |
Chemistry | |
AST | 83 U/l |
ALT | 62 U/l |
CPK | 511 U/l |
Cr | 0.89 mg/dl |
BUN | 15.7 mg/dl |
Na | 138 meq/l |
K | 3.3 meq/l |
Cl | 106 meq/l |
CRP | 0.01 mg/dl |
Coagulation | |
PT–INR | 1.56 |
APTT | 47.8 s |
Fib | 140 mg/dl |
Atrial blood gasa | |
pH | 7.244 |
PaCO2 | 37.8 mmHg |
PaO2 | 381 mmHg |
HCO3 − | 15.8 mmol/l |
Base excess | −10.3 mmol/l |
Lac | 6.8 mmol/l |
aO2 10-l non-rebreather mask
Discussion
We describe the severe ischemic complication of the lower extremities associated with sheath placement for REBOA. Potential ischemic complications of REBOA include acute kidney injury, vascular injury, bowel ischemia, spinal cord ischemia, and lower extremity ischemia [1]. However, incidence of these complications is very rare [2].
We believe that the use of large-sized sheaths for REBOA is a critical risk factor for lower extremity ischemia. In a prospective REBOA case registry, 74 % (34/46) of all REBOA interventions were performed using a 12- or 14-Fr sheath [2]. Although 7-Fr sheaths for REBOA are currently available and frequently used in Japan, this was not the case at the time of treatment of this patient. Therefore, we had to use a 12-Fr sheath. As blood flow is inversely proportional to the vessel cross-sectional area [3], it is acceptable that large-sized sheaths may decrease blood flow to the extremities. For example, the cross-sectional area of the blood flow was shown to reduce by 50 % in a model wherein a 12-Fr sheath (diameter 4 mm) is inserted in an artery with 5.6-mm diameter (the size of the femoral artery in our case) (Fig. 2). In a patient who underwent an attempted transfemoral transcatheter aortic valve replacement, a high sheath femoral artery diameter ratio and sheath femoral artery area ratio estimated on CT angiogram were reported as significant predictors of vascular complications [4]. Our patient was physically small (156 cm), and the diameter of his femoral artery on the contralateral site of sheath placement was also small (5.6 mm), according to the CT imaging after the primary surgery (Figs. 3 and 4). Therefore, disproportion of the sheath and femoral artery sizes may have caused the ischemic complication. We propose that the use of large-sized sheaths in small arteries increases the risk for lower extremity ischemia. Additionally, hypotension and occlusion of the aorta with REBOA may further aggravate the risk of ischemic complications due to decrease in lower extremity arterial flow. A retrospective study showed that 7-Fr sheaths for REBOA can be safely used [1]; however, even 7-Fr sheaths should be used with caution especially in small-built patients such as women or adolescents.
We believe that decreasing the duration of sheath placement and aorta occlusion may also help avert lower extremity ischemia. The reported median duration of sheath placement in a study was 28 (18–45) h, which is equal to the duration in our case (28 h) [5]. In an animal experiment, 60 min of REBOA was well tolerated and recoverable [6], and the median time of total balloon occlusion was reported as 26 (10–35) min, which is similar to that in our case [5]. Although the duration of sheath replacement and aorta occlusion in our case were believed to be tolerable, had we decreased the duration of sheath placement and aortal occlusion to as short as possible, the complication may have been averted.
Monitoring of lower extremity perfusion is essential to detect ischemia. We relied on visual examination and Doppler study for this purpose; however, we could not avoid the ischemic complication as both these methods lack objectivity and are prone to inter-observer variability. This probably contributed to the delay in the detection of ischemia. Near-infrared spectroscopy (NIRS) is reported as a good monitoring tool to detect lower extremity ischemia and compartment syndrome [7, 8]. Use of NIRS for this purpose should be considered.
Conclusions
We described severe lower extremity ischemia occurring as a complication of REBOA using 12-Fr sheath in a small-built patient. We highlighted the importance of appropriate size selection for the sheath in line with the target vessel. We also recommend postoperative monitoring of limb perfusion in such cases with the use of NIRS to facilitate early detection of ischemia.
Acknowledgments
We thank Drs. Kazumasa Oda, Satoshi Higaki, and Ken Sakakibara for their clinical support.
Funding
Not applicable.
Authors’ contributions
YO, WI, and RI were the major decision-makers during the surgery. HN revised the manuscript and study supervision. All authors have read and approved the final manuscript.
Competing interests
The authors declare that they have no competing interests.
Consent for publication
Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the editor of this journal.
Ethics approval and consent to participate
Not applicable.
Abbreviations
- CT
Computed tomography
- NIRS
Near-infrared spectroscopy
- REBOA
Resuscitative endovascular balloon occlusion of the aorta
Contributor Information
Yohei Okada, Phone: +81(75)2315171, Email: okadayohei1127@yahoo.co.jp.
Hiromichi Narumiya, Email: pyroli1117@gmail.com.
Wataru Ishi, Email: wataruaug0804@lily.ocn.ne.jp.
Iiduka Ryoji, Email: iizukar@kyoto2.jrc.or.jp.
References
- 1.Saito N, Matsumoto H, Yagi T, Hara Y, Hayashida K, Motomura T, et al. Evaluation of the safety and feasibility of resuscitative endovascular balloon occlusion of the aorta. J Trauma Acute Care Surg. 2015;78:897–903. doi: 10.1097/TA.0000000000000614. [DOI] [PubMed] [Google Scholar]
- 2.DuBose JJ, Scalea TM, Brenner M, Skiada D, Inaba K, Cannon J, et al. The AAST Prospective Aortic Occlusion for Resuscitation in Trauma and Acute Care Surgery (AORTA) Registry: data on contemporary utilization and outcomes of aortic occlusion and resuscitative balloon occlusion of the aorta (REBOA). J Trauma Acute Care Surg. 2016;81:409–19. [DOI] [PubMed]
- 3.Pfitzner J. Poiseuille and his law. Anaesthesia. 1976;31:273–5. doi: 10.1111/j.1365-2044.1976.tb11804.x. [DOI] [PubMed] [Google Scholar]
- 4.Krishnaswamy A, Parashar A, Agarwal S, Modi DK, Poddar KL, Svensson LG, et al. Predicting vascular complications during transfemoral transcatheter aortic valve replacement using computed tomography: a novel area-based index. Catheter Cardiovasc Interv. 2014;84:844–51. doi: 10.1002/ccd.25488. [DOI] [PubMed] [Google Scholar]
- 5.Teeter WA, Matsumoto J, Idoguchi K, Kon Y, Orita T, Funabiki T, et al. Smaller introducer sheaths for REBOA may be associated with fewer complications. J Trauma Acute Care Surg. 2016. [DOI] [PubMed]
- 6.Scott DJ, Eliason JL, Villamaria C, Morrison JJ, Houston R, Spencer JR, et al. A novel fluoroscopy-free, resuscitative endovascular aortic balloon occlusion system in a model of hemorrhagic shock. J Trauma Acute Care Surg. 2013;75:122–8. doi: 10.1097/TA.0b013e3182946746. [DOI] [PubMed] [Google Scholar]
- 7.Shuler MS, Reisman WM, Whitesides TE, Jr, Kinsey TL, Hammerberg EM, Davila MG, et al. Near-infrared spectroscopy in lower extremity trauma. J Bone Joint Surg Am. 2009;91:1360–8. doi: 10.2106/JBJS.H.00347. [DOI] [PubMed] [Google Scholar]
- 8.Prkic I, Stuth EA. Near-infrared spectroscopy provides continuous monitoring of compromised lower extremity perfusion during cardiac surgery. J Clin Anesth. 2016;31:38–41. doi: 10.1016/j.jclinane.2015.12.003. [DOI] [PubMed] [Google Scholar]