Abstract
Abstract
Volume rendering (VR) represents today’s standard three-dimensional (3-D) image post-processing technique, and often is used to visualize complex anatomical information. Recently, a novel 3-D technique for post-processing of computed tomography (CT) image data has been introduced, which is called cinematic rendering (CR). The objective of this review is to illustrate the image appearance and potential value of CR in comparison with conventional VR in a number of various applications and different anatomical regions. Similar to VR, CR best visualizes high density and high contrast structures such as bones and contrast-enhanced vessels, but at the same time provides a more natural and photo-realistic illumination of the rendered data. Further research will be necessary for determining possible advantages of CR over conventional VR and over two-dimensional (2-D) image post-processing for CT image data.
Teaching Points
• Cinematic rendering is a novel post-processing technique for 3D visualization of CT image data.
• Compared to volume rendering, CR results in a more photo-realistic representation of anatomy.
• Similar to volume rendering, CR provides best image quality of high density structures.
Keywords: Computed tomography, Image processing, Three-dimensional, Volume rendering, Cinematic rendering
Introduction
Current computed tomography (CT) scanners provide isotropic submillimeter resolution enabling the utilization of various 2-D and 3-D post-processing techniques with excellent image quality. Whereas 2-D techniques such as planar or curved multiplanar reformations (MPR) as well as maximum intensity projection (MIP) images can be considered part of daily radiological routine, 3-D imaging post-processing techniques such as surface shaded display (SSD) and volume rendering (VR) are mainly used to convey complex anatomy. Here, 3-D visualization of CT image data can offer important information compared with 2-D axial images alone both for pre-operative planning and post-treatment follow-up.
While the generation of VR images in the early days was hampered by high computational demands and often was associated with long post-processing times with considerable user interaction, today’s powerful computers allow for a near-real time and automatic rendering of 3-D images in a fast, clinically compatible manner. Thus, VR is today used as the standard technique for the 3-D visualization of CT image data. The main advantages of VR lie in a relatively simple evaluation of different anatomical structures of a larger body region at the same time. Moreover, VR enables the display of CT image data in a coloured fashion [1, 2].
However, the VR technique also suffers from some disadvantages. While VR can be helpful in evaluating complex anatomy, it can also mask anatomical information and, hence, pathology. This has been recently illustrated for the visualization of intracranial aneurysms with VR, where 3-D CT angiography with bone subtraction provided a significantly higher diagnostic accuracy compared to 3-D CT angiography without bone subtraction [3]. Thus, in order to avoid missing critical information, VR images should always be correlated and compared with corresponding MPR images.
Finally, it should be kept in mind that visualization of imaging data with VR – as with all other post-processing techniques such as MIP or SSD—never adds information to the reader beyond what is present in the original source images. It always remains an option for a different representation of imaging data, which might be helpful for anatomically complex structures and disease, and for easier and comprehensible illustration of imaging findings to clinicians.
Recently, a new technique for 3-D visualization of cross-sectional image data from CT has been introduced, which is entitled cinematic rendering (CR). CR works with random sampling computational algorithms and uses different light maps to generate a realistic depiction of medical data. While first studies have started using the CR technique for visualizing anatomy from CT data [4, 5], there is so far—to our knowledge—no publication describing and discussing the new technique in more detail.
Thus, the purpose of this pictorial review is to illustrate the potential value of CR in comparison with conventional VR in various applications and body regions. For doing so, we (i) summarized the technical background and potential clinical applications of the conventional VR technique, (ii) introduced the technical concept of CR, and (iii) selected a number of common and some rare pathology and disease for visualizing the potential of the new 3-D post-processing technique for CT image post-processing.
Volume rendering – technical background
The technical background of the VR technique has been repetitively explained in detail in a number of previous publications [2, 6]. VR represents a computer algorithm used to transform cross-sectional image datasets (from, e.g., CT or magnetic resonance (MR) imaging) into 3-D images. The VR technique consists of the following two steps: classification of each voxel and image projection. Classification determines how each point on the artificial rays that pass through the data contributes to the pixel value on the picture [7, 8]. For separation of different tissues (e.g., bone, soft tissue), a trapezoid is used for each tissue type. The tissue represented in each voxel of the volume dataset is determined by using predefined attenuation threshold levels and is assigned to a specific colour and opacity. Then, the weighted sum of the percentage of each tissue type represented in the voxel is calculated to determine the overall colour and transparency of each voxel. This step is performed for each voxel and for the whole volume dataset.
Then, the 3-D volume is displayed by using a projection technique. This is done by simulating rays of light, which are projected through the 3-D volume that contains the classified voxels. Each voxel, which is passed by the simulated rays, modulates the colour of the light depending on the assigned colour and transparency and contributes to the final projection and final image.
Finally, 3-D perception in the projected image can be enhanced by implementing additional effects, such as reflections and shadows on the surface of the rendered image. The final image can be manipulated by increasing or decreasing the slope of the trapezoid, which can be observed nearly in real time [8]. When sliding the trapezoid towards lower Hounsfield unit values, more structures with lower attenuation will be included (e.g., smaller vessels), and vice versa.
Volume rendering – potential clinical applications
Complex anatomy
Useful clinical applications of the VR technique for visualizing complex anatomy and pathology have been described in many radiological fields and include otorhinolaryngiology [9], neurosurgery and cranio-facial surgery [10], female imaging [1], vascular anomalies and variants [11, 12], and coronary artery anatomy and anomalies [13–15].
Pre-operative planning
In trauma patients, VR yields information about fragment size and position in relation to adjacent structures [16–19], and can be used as a preoperative and pre-radiotherapy planning tool leading to high satisfaction and acceptability from referring surgeons [20]. Also, imaging in oncology may profit from the application of the 3-D VR technique. VR can help evaluate tumour origin in difficult anatomical settings such as, e.g., in the pelvis [1], and can be used to determine tumour resectability and for preoperative planning [6].
Post-operative setting
The VR technique can also provide useful information in patients after surgery, such as, for example, for visualizing the results from endovascular aortic repair and the relationship between stent grafts and arterial vessels [21, 22]. An additional application of the VR technique is the visualization of the complex post-operative anatomy after coronary artery bypass graft surgery [23]. Here, the variable course of bypass grafts often crossing the axial image plane several times in different directions might be difficult to appreciate using 2-D post-processing tools alone. In regard to arteries and veins, VR provides visual information, which normally is obtained with conventional catheter angiography. Here, VR is not only noninvasive, but also fast and cost-effective [6].
Cinematic rendering – technical background
The development of CR was inspired by the entertainment industry based on the quality of computer animation programs in cinema, and had the aim to generate more photo-realistic representations of the human body from CT and MR image data sets.
CR is currently available as a research tool in an open research environment containing various prototype software (Frontier, version 1.0.0, syngo.Via, version VB10A, Siemens Healthcare, Forchheim, Germany) and has so far no approval for clinical use.
The CR technique [24] introduces a new paradigm, enabled by recent advances in computer graphics, to render volumetric medical image data by using a physically based real-time technique [25]. Conventional VR, such as ray casting [26] only considers emission and absorption of energy along a light ray to calculate 3-D images. Scattering effects are modelled using a local gradient shading model. Although simple to compute using a Riemann integral, such conventional approaches neglect complex light paths with multiple scattering patterns as well as light extinction, which might lead to a less artificial and potentially less accurate VR images.
As opposed to conventional VR methods, CR solves the multi-dimensional and non-continuous rendering equation [24] to integrate the light scattered from all possible directions along a ray. Thus, path tracing used in CT integrates a huge number of light rays, each with different paths to form each pixel of the rendered image. Since the number of light paths which can be traced is in theory infinite, and tracing of light paths is computationally expensive, Monte-Carlo simulations are used to generate a randomized subset of light paths with an adequate distribution. The final image is obtained iteratively by progressively averaging numerous Monte Carlo samples representing radiance at random positions with light scattered in random directions.
High dynamic range (HDR) rendering light maps are used for illumination, which lead to a natural illumination of the rendered data, in contrast to synthetic light sources used in conventional rendering methods such as VR [27].
As a result, the physically based VR method called CR computes in real-time the complex physics of lighting effects. It models shadows, ambient occlusion, multi-scattering, and color transmittance as well as sophisticated camera properties, which include concepts such as aperture, exposure and shutter speed. This approach leads to a natural and physically accurate presentation of the medical data, with a focus on an enhanced depth and shape perception [28].
The handling of transparency in CR does not differ from the conventional VR technique. The transparency is computed based on the transfer-function, which assigns colour and opacity to each attenuation value. Potential differences in transparency approaches can be easily adjusted by fine tuning of the transfer-function.
Representative image examples of CR in comparison with VR are provided in Figs. 1, 2, 3, and 4 for vascular anatomy and pathology, in Figs. 5, 6, and 7 for bones and skeletal disease, and in Figs. 8 and 9 for visualization of soft tissue anatomy. All CT source images were reconstructed with our default settings using a slice thickness of 2 mm (increment 1.5 mm), except for coronary CT angiography, which was reconstructed with a slice thickness of 0.75 mm (increment 0.5 mm). All CT angiography data were acquired after the intravenous injection of 50–80 ml non-ionic, iodinated contrast media (concentration 300–370 mg J/ml, depending on the body region).
Discussion
Both, VR and CR have the same general rendering concept in common: segmentation of data based on voxel attenuation and use of colour look-up tables taking into account opacity and brightness. As a consequence, both VR and CR share also the same problem of potentially masking findings in datasets by inappropriate use of rendering parameters and by adjacent structures [3]. Albeit CR currently is only provided by a single vendor in a pre-clinical research tool with still limited display options, CR can provide the same advanced display functions such as VR including flying-through, flying-around and multiple views of the volume data with independent parameters in equal segments of the displayed window [2, 6].
Due to the abovementioned similarities between CR and VR, there are no major differences in the visualization of CT image data when regarding the diagnostic value of the presentation. Similar to VR, we found that particularly high-contrast structures such as contrast-enhanced vessels and bones can be depicted with high quality also with CR. At the same time, we found a major improvement of CR for the perception of depth and soft tissue structures providing a more photo-realistic depiction of human anatomy and disease.
In general, lighting in 3-D rendered images such as VR and CR is a function of ambient, diffuse, and specular light properties. In both techniques, the brightness of each voxel is defined by the distribution of these light properties, which results in different lighting of different body parts relative to the artificial light source introduced into the volume, giving rise to 3-D impressions of the images. In VR, the differences in light emitted to the voxels are rather small. In contrast, CR uses a more complex lighting model taking into account the effect of lighting for other voxels and subsequent reflections as well. Also, the effect of body parts blocking the trace from the artificial light source to other structures introduces shadowing into the images. As a result of the differences in lighting functions—as being illustrated in the representative image examples of this pictorial review—CR images go along with a more natural image impression as compared to conventional VR.
Despite the potential benefits of CR compared to VR in the visualization of volume datasets, there is a higher computational power demand required for the CR technique because of the more complex lighting model. Therefore, real-time display of, for instance, rotating the CR image is currently interrupted by repetitive recalculation processes. Rendering of the final image needs some seconds, ranging from 5 to 30 s depending on the quality of the resulting image [28].
One major limitation of this pictorial review is that we focused our comparison of VR and CR on some clinical cases to highlight the differences in image appearance between both post-processing methods. However, we did not perform an analysis of both methods regarding the diagnostic performance for the diagnosis of specific pathological entities. Here, future studies should determine whether or not there is an improvement of the new 3-D imaging technique described herein.
Conclusion
This pictorial review aimed at a first, preliminary demonstration of a new post-processing technique for the 3-D visualization of CT image data. Our initial experience indicates that CR of CT images is particularly impressive when high density and high contrast structures such as bones and contrast-enhanced vessels are to be visualized. The main innovation as compared to conventional VR appear to be the more natural and photo-realistic representation of the CT image data, with an enhanced and more natural depth and shape perception. Future studies should aim at determining whether the CR technique offers advantages over cross-sectional and 3-D CT images in terms of a diagnostic gain.
Acknowledgments
We thank Dr. Razvan Ionasec and Dr. Max Schoebinger (both Siemens Healthineers) for their valuable input regarding the technical background of cinematic rendering.
Compliance with ethical standards
Conflict of interest
None.
Funding
None.
References
- 1.Li Y, Zheng Y, Chen J, Chen X, Lin J, Cai A, et al. Determining the organ of origin of large pelvic masses in females using multidetector CT angiography and three-dimensional volume rendering CT angiography. Eur Radiol. 2015;25(4):1032–1039. doi: 10.1007/s00330-014-3471-8. [DOI] [PubMed] [Google Scholar]
- 2.Fishman EK, Ney DR, Heath DG, Corl FM, Horton KM, Johnson PT. Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why. Radiog : Rev Publ Radiol Soc North Am, Inc. 2006;26(3):905–922. doi: 10.1148/rg.263055186. [DOI] [PubMed] [Google Scholar]
- 3.Hwang SB, Kwak HS, Han YM, Chung GH. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: is bone subtraction necessary? Eur J Radiol. 2011;79(2):e18–e23. doi: 10.1016/j.ejrad.2010.01.004. [DOI] [PubMed] [Google Scholar]
- 4.Higashigaito K, Schmid T, Puippe G, Morsbach F, Lachat M, Seifert B, et al. (2016) CT Angiography of the aorta: prospective evaluation of individualized low-volume contrast media protocols. Radiology 280(3):960–968 [DOI] [PubMed]
- 5.Higashigaito K, Husarik DB, Barthelmes J, Plass AR, Manka R, Maisano F et al (2016) Computed tomography angiography of coronary artery bypass grafts: low contrast media volume protocols adapted to tube voltage. Invest Radiol 51(4):241–8 [DOI] [PubMed]
- 6.Calhoun PS, Kuszyk BS, Heath DG, Carley JC, Fishman EK. Three-dimensional volume rendering of spiral CT data: theory and method. Radiog : Rev Publ Radiol Soc North Am, Inc. 1999;19(3):745–764. doi: 10.1148/radiographics.19.3.g99ma14745. [DOI] [PubMed] [Google Scholar]
- 7.Luccichenti G, Cademartiri F, Pezzella FR, Runza G, Belgrano M, Midiri M, et al. 3D reconstruction techniques made easy: know-how and pictures. Eur Radiol. 2005;15(10):2146–2156. doi: 10.1007/s00330-005-2738-5. [DOI] [PubMed] [Google Scholar]
- 8.Lell MM, Anders K, Uder M, Klotz E, Ditt H, Vega-Higuera F, et al. New techniques in CT angiography. Radiog : Rev Publ Radiol Soc North Am, Inc. 2006;26(Suppl 1):S45–S62. doi: 10.1148/rg.26si065508. [DOI] [PubMed] [Google Scholar]
- 9.Guo Y, Liu Y, Lu QH, Zheng KH, Shi LJ, Wang QJ. CT two-dimensional reformation versus three-dimensional volume rendering with regard to surgical findings in the preoperative assessment of the ossicular chain in chronic suppurative otitis media. Eur J Radiol. 2013;82(9):1519–1524. doi: 10.1016/j.ejrad.2013.03.010. [DOI] [PubMed] [Google Scholar]
- 10.Sun W, Jia L, Dong Y, Zhao H, Liu H, Yang K, et al. Morphological study of surgical approach by superior temporal sulcus-temporal horn of lateral ventricle approach using volume rendering. J Craniofacial Surg. 2014;25(2):611–613. doi: 10.1097/SCS.0000000000000444. [DOI] [PubMed] [Google Scholar]
- 11.Li HO, Huo R, Wang XM, Xu GQ, Duan YH, Nie P, et al. High-pitch spiral CT with 3D reformation: an alternative choice for imaging vascular anomalies with affluent blood flow in the head and neck of infants and children. Br J Radiol. 2015;88(1052):20150005. doi: 10.1259/bjr.20150005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Abdullah A, Williamson K, Lewis T, Elsamaloty H. Variant ventral intrahepatic course of inferior vena cava: volume-rendering and maximum intensity projection CT findings. Br J Radiol. 2011;84(1003):e135–e137. doi: 10.1259/bjr/51830082. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Mlynarski R, Mlynarska A, Sosnowski M. Anatomical variants of left circumflex artery, coronary sinus and mitral valve can determine safety of percutaneous mitral annuloplasty. Cardiol J. 2013;20(3):235–240. doi: 10.5603/CJ.2013.0067. [DOI] [PubMed] [Google Scholar]
- 14.Graidis C, Dimitriadis D, Karasavvidis V, Dimitriadis G, Argyropoulou E, Economou F, et al. Prevalence and characteristics of coronary artery anomalies in an adult population undergoing multidetector-row computed tomography for the evaluation of coronary artery disease. BMC Cardiovasc Disord. 2015;15:112. doi: 10.1186/s12872-015-0098-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Karlo CA, Leschka S, Stolzmann P, Glaser-Gallion N, Wildermuth S, Alkadhi H. A systematic approach for analysis, interpretation, and reporting of coronary CTA studies. Insights Imag. 2012;3(3):215–228. doi: 10.1007/s13244-012-0167-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Falchi M, Rollandi GA. CT of pelvic fractures. Eur J Radiol. 2004;50(1):96–105. doi: 10.1016/j.ejrad.2003.11.019. [DOI] [PubMed] [Google Scholar]
- 17.Song SW, Jun BC, Chae SR, Kim BG. Clinical utility of three-dimensional facial computed tomography in the treatment of nasal bone fractures: a new modality involving an air-bone view with a volume rendering technique. Indian J Otolaryngol Head Neck Surg : Off Publ Assoc| Otolaryngol India. 2013;65(Suppl 2):210–215. doi: 10.1007/s12070-011-0318-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Schmidle G, Rieger M, Klauser AS, Thauerer M, Hoermann R, Gabl M. Intraosseous rotation of the scaphoid: assessment by using a 3D CT model--an anatomic study. Eur Radiol. 2014;24(6):1357–1365. doi: 10.1007/s00330-014-3116-y. [DOI] [PubMed] [Google Scholar]
- 19.Mirka H, Ferda J, Baxa J. Multidetector computed tomography of chest trauma: indications, technique and interpretation. Insights Imag. 2012;3(5):433–449. doi: 10.1007/s13244-012-0187-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Wang H, Wang F, Newman S, Lin Y, Chen X, Xu L et al. (2016) Application of an innovative computerized virtual planning system in acetabular fracture surgery: a feasibility study. Injury 47(8):1698–1701 [DOI] [PubMed]
- 21.Sun Z. Multislice CT, angiography in abdominal aortic aneurysm treated with endovascular stent grafts: evaluation of 2D and 3D visualisations. Biomed Imag Interven J. 2007;3(4):e20. doi: 10.2349/biij.3.4.e20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Iezzi R, Santoro M, Dattesi R, Pirro F, Nestola M, Spigonardo F, et al. Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR) Insights Imag. 2012;3(4):313–321. doi: 10.1007/s13244-012-0173-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Frazier AA, Qureshi F, Read KM, Gilkeson RC, Poston RS, White CS. Coronary artery bypass grafts: assessment with multidetector CT in the early and late postoperative settings. Radiog : Rev Publ Radiol Soc North Am, Inc. 2005;25(4):881–896. doi: 10.1148/rg.254045151. [DOI] [PubMed] [Google Scholar]
- 24.Comaniciu D, Engel K, Georgescu B, Mansi T. (2016) Shaping the FUTURE through innovations: from medical imaging to precision medicine. Medical Image Analysis, Elsevier. 2016; 20th Anniversary Special Issue [DOI] [PubMed]
- 25.Kroes T, Post FH, Botha CP. Exposure render: an interactive photo-realistic volume rendering framework. PLoS One. 2012;7(7):e38586. doi: 10.1371/journal.pone.0038586. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Engel K, Hadwiger M, Kniss J, Rezk-Salama C, Weiskopf D. (2006) Real-time volume graphics: AK Peters
- 27.Debevec ZH (1998) Rendering synthetic objects into real scenes: bridging traditional and image-based graphics with global illumination and high dynamic range photography. Proc SIGGRAPH ’98:189-98.
- 28.Fellner FA. Introducing cinematic rendering: a novel technique for post-processing medical imaging data. J Biomed Sci Eng. 2016;9:170–175. doi: 10.4236/jbise.2016.93013. [DOI] [Google Scholar]