Highlights
-
•
Laparoscopic adjustable gastric banding is one of the most common bariatric procedures done.
-
•
The most reported complications of this technique are related to the band around the stomach.
-
•
This case report describes a case of acute abdomen caused by the connecting tube of the gastric band.
-
•
The tube looped around the root of mesentry and caused incarceration of the small intestine.
-
•
This complication, although rare, should be kept in mind due to its serious effects.
Keywords: Case report, Laparoscopic gastric banding, Acute abdomen, Bowel herniation, Connecting tube
Abstract
Introduction
Laparoscopic adjustable gastric banding is one of the most frequently done procedures for morbid obesity. In most reported cases, the band itself is the cause of complications. There are only a few reports of morbidities caused by the connecting tube. This presentation describes a case of acute abdomen due to small bowel herniation between the connecting tube and the abdominal wall. This case report aims to remind clinicians of possible complications caused by the connecting tube of a gastric band.
Case presentation
We report about a 24-year-old male patient, who presented with acute abdomen. He had undergone gastric banding three years ago. According to his clinical presentation, the patient was diagnosed as having acute appendicitis.
Abdominal exploration revealed, total small bowel herniation between the connecting tube and the abdominal wall.
Discussion
Although a simple procedure, laparoscopic gastric banding could have serious complications. Some of these complications could present years after the application of the gastric band. There are a few reports about complications caused by the connecting tube of the gastric band.
Conclusion
Complications caused by connecting tube should always be in mind, when assessing acute abdomen in patients with laparoscopic gastric band.
1. Introduction
Laparoscopic adjustable banding is one of the most pervasive techniques in bariatric surgery [1]. The operation entails the application of a silicon band containing a balloon around the upper segment of the stomach. The band connects through a tube to a subcutaneous port. Repeated filling of the band is achieved through the subcutaneous port. This allows the creation of two gastric reservoirs.
The most common complications of gastric banding include band migration with stomach perforation, band slippage with pouch dilatation and band leakage [2]. Complications caused by the connecting tube are rare, but could be life threatening [3], [4].
We report a case of small bowel herniation between the connecting tube and the abdominal wall. The patient presented with acute abdomen to the emergency department of the Air force Specialized Hospital in Cairo. He was misdiagnosed as a case of acute appendicitis.
2. Case presentation
A 24-year-old male patient presented to the ER with acute onset of periumbilical pain, which shifted to the right iliac fossa. In addition, there was repeated vomiting. He had undergone laparoscopic gastric banding three years ago. His BMI was 38.1 kg/m2 before ligation and dropped to 28.2 kg/m2 at the time of presentation. The drug and family history were irrelevant. Examination revealed tachycardia 110/min, normal temperature 37.2° and a blood pressure of 110/70. Abdominal examination revealed periumbilical tenderness, with maximal tenderness locating in the right iliac fossa. However, there was neither rebound tenderness nor rigidity or guarding. The patient was in severe pain out of proportion to his abdominal examination.
3. Timeline

Abdominal ultrasonography revealed only a moderate degree of bowel loop distension. His total leukocytes’ count was 5800 cells/μL, with shift to the left.
The patient was diagnosed as a case of acute appendicitis, and was transferred to operating theatre. Eventually, this turned out to be a misdiagnosis.
Under general anesthesia, McBurney’s incision was done, and exposure of the appendix revealed an almost normal appendix (Fig. 1). The operating surgeon was a middle stage consultant of general surgery and surgical oncology. He noticed severely distended and congested small bowel loops, and felt a tube like structure other than the appendix.
Fig. 1.
A normal appendix was found through a McBurney’s incision.
Decision was taken to explore the abdomen through a midline incision. The exploration revealed a severely dilated and congested proximal jejunum (Fig. 2).
Fig. 2.
Congested, dilated jejunum was found upon exploration.
The connecting tube of the gastric band system was found looping around the root of mesentery causing incarceration (Fig. 3, Fig. 4). The small intestine had herniated through the space between the connecting tube and the abdominal wall. Thorough examination of the stomach and small bowel revealed no perforation.
Fig. 3.
Connecting tube identified.
Fig. 4.
Connecting tube looping around root of mesentery.
The band was deflated through the subcutaneous port, and the complete gastric banding system was removed, after cutting the band. The patient had a smooth postoperative course in a regular surgical ward. He was discharged 48 h post operatively.
The patient came for follow up in the outpatient clinic two weeks after discharge. He had clean wounds, and reported full recovery.
4. Discussion
Although laparoscopic adjustable gastric banding is a quick and simple procedure for the management of morbid obesity, yet it is not without complications. Most reported complications are related to the band itself. However, there are limited reports of morbidities due to the connecting tube. Although rare, these morbidities could be quite serious, and could mimic other acute abdominal conditions. Timely intervention warrants a high degree of clinical suspicion. The prompt surgical intervention in this case has prevented propagation to intestinal perforation or ischemia. Adequate assessment of other organs near the appendix is crucial during appendectomy. This is especially important, when the appendix is normal, or slightly inflamed. The operating surgeon should not overlook any abnormality found during laparotomies.
5. Conclusion
Laparoscopic adjustable gastric banding is one of the frequently done procedures for morbid obesity patients. The possibility of complications by the connecting tube should not be excluded in a patient with acute abdomen, and previous history of gastric banding.
Conflicts of interest
The authors have no conflict of interest to disclose.
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or non-profit sectors.
This work has been reported in line with the SCARE criteria [5].
Ethical approval
This case report involved no research. Studies done on patients.
Consent
An informed signed consent was taken from the patient prior to publication of his medical data.
Author contribution
All authors have contributed in all steps of accomplishing this case report.
Guarantor
All three authors are guarantors for the report.
References
- 1.Bobowicz M., Michalik M., Orłowski M., Frask A. Bariatric single incision laparoscopic surgery – review of initial experience. Videosurg. Miniinvasive Tech. 2011;6:48–52. [Google Scholar]
- 2.Eid I., Birch D.W., Sharma A.M., Sherman V., Shahzeer K. Complications associated with adjustable gastric banding for morbid obesity: a surgeon’s guide. Can. J. Surg. 2011;54(1):61–66. doi: 10.1503/cjs.015709. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Zappa M.A., Lattuada E., Mozzi E. An unusual complication of gastric banding: recurrent small bowel obstruction caused by the connecting tube. Obes. Surg. 2006;16(7):939–941. doi: 10.1381/096089206777822250. [DOI] [PubMed] [Google Scholar]
- 4.Van DeWater W., Vogelaar F.J., Willems J.M. An unusual complication 4 years after laparoscopic adjustable banding: jejunal obstruction due to the connecting tube. Obes. Surg. 2011;21(1):131–133. doi: 10.1007/s11695-009-0057-7. [DOI] [PubMed] [Google Scholar]
- 5.Agha R.A., Fowler A.J., Saetta A., Barai I., Rajmohan S., Orgill D.P., for the SCARE group The SCARE statement: consensus-based surgical case report guidelines. Int. J. Surg. 2016 doi: 10.1016/j.ijsu.2016.08.014. (article in press) [DOI] [PubMed] [Google Scholar]