Skip to main content
Clinical Case Reports logoLink to Clinical Case Reports
. 2016 Nov 11;4(12):1215–1216. doi: 10.1002/ccr3.744

Contrast‐enhanced transoral carotid ultrasonography for the evaluation of a long stenotic lesion in the internal carotid artery

Yuta Hagiwara 1,, Tomohide Yoshie 2, Takahiro Shimizu 1, Hana Ogura 1, Masashi Akamatsu 1, Takayuki Fukano 2, Tatsuro Takada 2, Shinji Nogoshi 2, Toshihiro Ueda 2, Yasuhiro Hasegawa 1
PMCID: PMC5134147  PMID: 27980770

Key Clinical Message

Contrast‐enhanced transoral carotid ultrasonography (CETOCU) is a novel modality for imaging the distal extracranial internal carotid artery, which is not possible with conventional carotid ultrasonography. We present a representative case that demonstrates the usefulness of CETOCU.

Keywords: carotid ultrasonography and carotid artery stenosis


Contrast‐enhanced transoral carotid ultrasonography (CETOCU), which is essentially transoral carotid ultrasonography 1 performed with ultrasonography contrast agent 2, produces clearer intraluminal imaging as the contrast agent flows through the lumen. In CETOCU, an endovaginal probe is inserted into the mouth and pressed against the wall of the pharynx. CETOCU enables imaging for 5 min after contrast agent injection and thus allows focused evaluation of the region of interest. CETOCU imaging with characterization of plaque vulnerability enables us to select a suitable type and length of carotid stent encompassing the whole length of the atheromatous plaque (Figs 1 and 2).

Figure 1.

Figure 1

Right carotid angiogram. Carotid angiogram performed on a 73‐year‐old man with asymptomatic stenosis of the right internal carotid artery. Carotid angiogram reveals a long stenosis with irregular surface morphology. At the upper end of the atheroma, an ulcerative complex lesion is suspected (arrow). However, this lesion is located far above the mandibular angle; thus, further evaluation by transoral carotid ultrasonography is indicated.

Figure 2.

Figure 2

(A) Contrast‐enhanced transoral carotid ultrasonography (CETOCU) of the right internal carotid artery (video clip). (B) Schematic image of (A). CETOCU is performed using a Xario ultrasonography system equipped with a PVT‐661VT 3–9 MHz Endovaginal Probe (both Toshiba Medical Systems, Tokyo, Japan). CETOCU reveals that the surface morphology of the notch was smooth and had no intraplaque neovascularization. These findings suggest that the ulcer‐like lesion on carotid angiogram is not a complex atheromatous lesion but a stable plaque.

Conflict of Interest

All authors report no disclosures.

Authorship

YH: involved in study concept, acquisition of data, analysis, and interpretation. TY, TS, HO, MA, TF, TT, and SN: involved in acquisition of data. TU: involved in study supervision. YH: involved in critical revision of the manuscript for important intellectual content and study supervision.

Supporting information

Video S1. Video shows view of examination by CETOCU for a long stenotic internal carotid artery.

References

  • 1. Yasaka, M. , Kimura K., Otsubo R., et al. 1998. Transoral carotid ultrasonography. Stroke 29:1383–1388. [DOI] [PubMed] [Google Scholar]
  • 2. Matsumoto, N. , Kimura K., Uno M., et al. 2012. Enhanced carotid plaque on contrast – enhanced ultrasound is associated with plaque instability and rupture. Int. J. Stroke 7:E12. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Video S1. Video shows view of examination by CETOCU for a long stenotic internal carotid artery.


Articles from Clinical Case Reports are provided here courtesy of Wiley

RESOURCES