Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2016 Dec 5;6:38552. doi: 10.1038/srep38552

A novel open-type biosensor for the in-situ monitoring of biochemical oxygen demand in an aerobic environment

Takahiro Yamashita 1,*, Natsuki Ookawa 2,*, Mitsuyoshi Ishida 1, Hiroyuki Kanamori 3, Harumi Sasaki 3, Yuichi Katayose 3, Hiroshi Yokoyama 1,a
PMCID: PMC5137150  PMID: 27917947

Abstract

Biochemical oxygen demand (BOD) is a widely used index of water-quality assessment. Since bioelectrochemical BOD biosensors require anaerobic conditions for anodic reactions, they are not directly used in aerobic environments such as aeration tanks. Normally, the BOD biosensors are closed-type, where the anode is packed inside a closed chamber to avoid exposure to oxygen. In this study, a novel bioelectrochemical open-type biosensor was designed for in-situ monitoring of BOD during intermittent aeration. The open-type anode, without any protection against exposure to oxygen, was directly inserted into an intermittently aerated tank filled with livestock wastewater. Anodic potential was controlled using a potentiostat. Interestingly, this novel biosensor generated similar levels of current under both aerating and non-aerating conditions, and showed a logarithmic correlation (R2 > 0.9) of current with BOD concentrations up to 250 mg/L. Suspended solids in the wastewater attached to and covered the whole anode, presumably leading to the production of anaerobic conditions inside the covered anode via biological oxygen removal. Exoelectrogenic anaerobes (Geobacter spp.) were detected inside the covered anode using the 16S-rRNA gene. This biosensor will have various practical applications, such as the automatic control of aeration intensity and the in-situ monitoring of natural water environments.


Biochemical oxygen demand (BOD) is a measure of easily biodegradable organic compounds, and is one of the most widely used criteria for the assessment of water quality1. The standard method of BOD measurement is lengthy (typically 5 days: BOD5), and requires a trained technician to obtain reproducible results. Thus, the method is not suitable for process control in wastewater treatment and the real-time monitoring of water environments, such as rivers, streams, ponds, and ground water. The development of in-situ and real-time BOD monitoring techniques that can be directly applied to aerobic environments would advance current wastewater treatment methods, as well as aid in the preservation of water resources. Most notably, the proper automatic control of aeration duration, based on real-time BOD values, is desirable for the intermittent aeration process to efficiently remove both BOD and nitrogen from wastewater2. Many BOD biosensors designed to shorten the requisite measurement time have been developed3, including those based on bacterial respiration4,5,6, oxygen consumption by immobilised bacteria7,8, enzymatic reactions in dead cells9, and bioluminescence10. These biosensors measure BOD in short time—approximately 10 min to 1 hour—and show a high correlation with BOD5. However, these methods are complicated3, and the measurements are conducted ex situ (not in situ). Additionally, other sensors that use non-biological mechanisms have been reported for estimating BOD5, including those based on UV absorbance11 and fluorescence12. While these sensors conduct precise in situ monitoring of organic matters, the major drawback is that the sensors measure the total concentration of organic carbon, including non-biodegradable substances. In addition, these sensors are not suited for monitoring coloured wastewater and wastewater containing a high quantity of suspended solids (SS) owing to low light permeability13.

Bioelectrochemical systems (BESs) are emerging as an intriguing technology platform with various applications14. BESs comprise microbial fuel cells (MFCs) for the generation of electricity15 and microbial electrolysis cells (MECs) for the production of H216. Geobacter spp. are representative exoelectrogenic bacteria and are frequently observed in the biofilm that develops on the anodes of BESs17. Originally, Geobacter spp. were isolated as Fe(III)-oxide reducing bacteria, which oxidise acetate to CO2, coupled with Fe(III) reduction, under anaerobic conditions18. These bacteria attach to the anodes of BESs, and transfer electrons to the anode via the oxidation of acetate19. Since the electron-transfer reaction also occurs only under anaerobic conditions, microbial BES-based devices require anaerobic environments in the vicinity of the anodes for current production. Thus, BESs-based biodevices are not currently directly applied in aerobic environments, such as on the interior of aeration tanks, and are usually designed as closed-type sensors, where the anode is packed inside a closed chamber to protect it from exposure to oxygen.

A BOD biosensor, based on a MFC using a bacterial consortium, was reported by Kim et al. in ref. 20. This biosensor was a two-chambered mediator-less MFC, and showed a strong linear correlation of charge with BOD5 concentrations up to 206 mg/L (R2 = 0.99). Another two-chambered MFC-based biosensor was developed for the continuous monitoring of BOD5 concentrations up to 200 mg/L21. A biosensor based on an air-cathode, single-chambered MFC displayed a linear correlation (R2 = 0.93) with BOD5 concentrations up to 350 mg/L22. Additionally, a BES-based biosensor with voltage input was demonstrated to have a wide detection range from 32 to 1,280 mg/L with a linear correlation (R2 = 0.97) of charge with BOD523. However, these biosensors were performing ex situ monitoring under anaerobic conditions. An interesting biosensor, a submersible MFC-based device equipped with a blower to continuously aerate the cathode chamber, was developed for the in situ monitoring of BOD5 in groundwater, and showed a linear correlation of current with BOD5 up to 250 mg/L24. Although this biosensor was operated under anaerobic conditions, current production under aerobic conditions was not demonstrated. At present, there is no in situ BOD biosensor for direct use in an aerobic environment. Therefore, in the present study, we designed a novel configuration of an in situ, BES-based, open-type BOD (iBOB) biosensor that is directly applied during an intermittent aeration process. Furthermore, the bacterial community structure of the biofilm that developed on the anode was characterised in detail via next-generation sequencing technology using the 16 S rRNA gene.

Results

Current generation in aerobic environment

The iBOB biosensor is a membrane-less device with an open-type anode (i.e. the anode is directly inserted into water without any protection against exposure to oxygen) (Fig. 1). The two anodes, along with an Ag/AgCl-reference electrode with a double junction and a counter electrode, were placed in a pilot-scale aeration tank (1.2 m3), and the anodic potential was controlled at a constant level using a potentiostat. The tank was intermittently aerated and was periodically supplied with livestock wastewater at a hydraulic retention time (HRT) of 4 days. To prevent adhesion of SS, the reference electrode was placed above a diffuser tube such that air bubbles from the tube directly struck the electrode and washed the SS away. In contrast, the anodes were not placed above the tube, ensuring tight adhesion of SS. After running for several weeks, pollutants (BOD5, SS, NH4-N and total nitrogen) in the wastewater were efficiently removed (>90%) by the intermittent aeration in a cycle of 2 h of aeration and 2 h of non-aeration (Table S1). The pH in the tank was in the range of 7.5–7.8. The dissolved oxygen (DO) of the wastewater was not detectable during the non-aerating phase, increasing in value to approximately 6–7 mg/L during the aerating phase (Fig. 2). The oxidation–reduction potential (ORP) of the wastewater also increased from −100 to −150 mV to 200–300 mV (vs. NHE) during aerating phase. The DO and ORP values conveyed that the aerobic and anaerobic environments repeatedly occurred in the tank as a result of the intermittent aeration. Bacteria naturally present in the wastewater functioned as the seed bacteria for current production. The iBOB biosensor stably generated current after approximately 2 to 3 weeks of operation. The current intensity in the non-aerating phase was 5.8–9.6 mA at an average of 8.2 ± 0.8 mA (Fig. 2). Interestingly, despite the aerobic environment, the biosensor also generated current during the aerating phase. The current intensity in the aerating phase was 6.9–11.6 mA, with an average of 9.0 ± 1.1 mA, which was slightly higher than the average observed in the non-aerating phase. This could be the result of the stirring of the wastewater by aeration, which may have been supplying fresh substrates and/or washing off inhibitory by-products from the anodic surface. SS, including small particles of hay feed, in the wastewater attached to and covered the whole surface of the anodes (Fig. 3). The amount of biomass attached was 29.4–37.9 g dry wt/g anode. Bacteria present on the outside area of the covered anodes were considered to consume oxygen, by which anaerobic environments could be produced inside the covered anodes. These results demonstrated that the iBOB biosensor is capable of generating current from the wastewater in the aerating phase.

Figure 1. Schematic representation of the iBOB biosensor inserted into an intermittently aerating tank.

Figure 1

Figure 2. Current generation of the iBOB biosensor during aerating (orange arrows) and non-aerating (green arrows) phases.

Figure 2

. The aeration tank, fed periodically with the wastewater, was aerated in a cycle of 2 h aeration and 2 h non-aeration. The profiles of current, DO, and ORP are shown. The time points of wastewater feeding and sampling for BOD5 measurement are indicated with blue and red arrows, respectively.

Figure 3.

Figure 3

Anodes of the iBOB biosensor before (a) and after (b) use. The anode completely covered with SS, including hay feed, is shown.

Monitoring of BOD5 in the intermittently aerating tank

To analyse the relationship between current and BOD5 concentration, the tank was operated at different HRTs and aeration cycles, and BOD5 values ranging from 14 to 570 mg/L were obtained. The iBOB biosensor generated current at all BOD5 concentrations, and the levels and wave profiles of current generation appeared to be similar in both the aerating and non-aerating phases (Fig. 4). The current generation sharply increased with the increase in BOD5, ranging from 14 to 100 mg/L in both phases (Fig. 5, upper panels). Subsequently, the slope corresponding to current generation decreased with increasing BOD5 (>100 mg/L), and the current generation reached a plateau (17 mA) at 250 mg/L BOD5. The current displayed a logarithmic correlation with BOD5 in both phases (i.e. current was linearly correlated with the values of logarithmically converted BOD5) (Fig. 5, lower panels). The regression formulas for each phase are shown in Fig. 5, and the R2 values were greater than 0.9 in both phases. The superposed graphs in Fig. 5 (right panels) show that the generation of current in the aerating phase was nearly equal to or slightly higher than in non-aerating phase. On the basis of a t-test, the logarithmic coefficient in the regression formula for the aerating phase (5.20) was significantly higher (P < 0.05) than that for the non-aerating phase (4.41).

Figure 4. Profiles of current generation by the iBOB biosensor at various BOD5 concentrations in the intermittently aerated tank.

Figure 4

The zero value on the horizontal axis indicates the time point of switching from the aerating to the non-aerating phase. BOD5 concentrations are indicated by colour.

Figure 5. Correlation of current with BOD5 in aerating (left) and non-aerating phase (middle).

Figure 5

Right panels are the superposition of left and middle panels. In the lower panels, the linear correlation of current with the values of logarithmically converted BOD5 is shown.

The biosensor stably generated current until the end of experiment (71 days), and no maintenance of the anodes, such as washing or replacement, was required. The amount of SS attached to the reference electrode was very slight, and the filter at the junction of the electrode appeared clean; no biofilm formation was observed on the surface. Deterioration of the counter electrode was not observed.

Bacterial community structure

To reveal the bacteria involved in the generation of current, the communities for the planktonic-cell fraction (PC) in the aeration tank and the whole-anode (WA) and anode-binding (AB) fractions from the iBOB biosensor, were analysed using high-throughput sequencing of the 16 S rRNA gene. The AB sample was prepared by washing the WA sample until the visible SS that were adhered to the anode disappeared. The distribution of the operational taxonomic units (OTUs) and alpha diversity of the communities are shown in Table S2. Based on the alpha-diversity indices, the level of diversity was similar among the communities. The rarefaction curve suggested that the number of OTUs observed did not reach a plateau in all communities (Fig. S1). Planctomycetes was the most abundant phylum (29%) in the AB sample, whereas the candidate phylum Parcubacteria25, previously called OD1, was the most predominant (45–48%) in the PC and WA samples (Fig. 6). The phylum Proteobacteria, which includes exoelectrogenic and metal-oxide reducing bacteria, was detected in the AB sample at a higher frequency (16%) than in the PC and WA samples. In the genus-level analysis (Fig. 7), the exoelectrogenic genus Geobacter in the AB sample was observed at a significantly higher frequency (6.4%) than that in the PC (0%) and WA (0.2%) samples. The class Planctomycetia, in the phylum Planctomycetes, in the AB sample occurred at a higher frequency (13.6%) than that in the PC and WA (2.0–4.3%) samples.

Figure 6. Phylum-level community structures of planktonic-cell (PC) fraction in the aeration tank and whole-anode (WA) and anode-binding (AB) fractions from the iBOB biosensor.

Figure 6

Figure 7. Phylogenetically clustered heat map of the major genera in the communities of the planktonic-cell (PC) fraction in the aeration tank and the whole-anode (WA) and anode-binding (AB) fractions from the iBOB biosensor.

Figure 7

Discussion

This study is the first report demonstrating the direct application of a novel biosensor, iBOB, in an aerobic environment for the in situ monitoring of BOD5. The most distinctive feature of the iBOB biosensor is the novel open-type configuration, where anodic potential is controlled at a constant level using a potentiostat, and the probe can be directly inserted into an intermittently aerated tank without any protection against exposure to oxygen. Thus far, BES-based biodevices, including MFCs, have been used in anaerobic environments, as anaerobic conditions are essential for the anodic reactions. Despite the aerobic environment, iBOB generated current during the aerating phase, likely via biological oxygen removal on the outer region of the anode covered with high amounts of SS. Geobacter spp., which are strictly anaerobic18, were observed in the iBOB biosensor, indicating that anaerobic conditions were produced inside the covered anode. Geobacter spp. could be mainly responsible for the generation of current in the iBOB biosensor via similar mechanisms observed with MFCs. In a preliminary experiment using a small-size anode, intermittently aerating tank (10 L), and artificial wastewater, we observed current production of the iBOB biosensor in the aerating phase, demonstrating the reproducibility of the BOD sensing under aerobic conditions (Fig. S2). Thus, this study suggests that, as a result of a thick biofilm on the anode, the application scope of BES-based biodevices is extended from anaerobic to aerobic environments. In addition, although the phylum Planctomycetes is rarely detected at a high frequency on MFCs, this phylum was detected at a high frequency on the iBOB biosensor. The class Planctomycetia in this phylum includes a diverse array of bacteria, such as aerobic heterotrophic bacteria and anaerobic ammonium oxidation (anammox) bacteria, which oxidise ammonia into N2 gas using nitrite as an oxidising agent under anaerobic conditions26. Despite this, there are no known exoelectrogenic members of the class Planctomycetia. The Planctomycetes-dominant community structure observed in our study is an intriguing signature of the iBOB biosensor, although the role of Planctomycetes in the generation of current is unclear.

MFC-based BOD biosensors frequently show linear correlations of current or charge with BOD5. However, in the present study, we observed a logarithmic correlation of current with BOD5 for the iBOB biosensor. In MFCs, current generation is dependent on both anode and cathode reactions, where the cathode reaction is known to have a substantial effect on current production. When the Pt catalyst of the cathode is poisoned, the MFC-based BOD sensor will decrease current production, leading to an error signal. On the other hand, the anodic potential is kept continuously constant using a potentiostat in the iBOB biosensor, and thus, the current generation is dependent only on anodic conditions. In this regard, the iBOB biosensor is predicted to generate current in a more stable manner than MFC-based biosensors. With this information in mind, it stands to reason that the regression formula for the iBOB biosensor might be different from those of MFC-based biosensors as a result of their dependency on the cathode. We observed that current generation of the iBOB biosensor sharply increased until BOD5 concentrations reached 100 mg/L in both the aerating and non-aerating phases, and subsequently reached a plateau at 250 mg/L. Therefore, we conclude that the range of high sensitivity detection for BOD5 in livestock wastewater is 14 to 100 mg/L, and that low sensitivity detection is possible up to 250 mg/L. Nearly identical, but not equal, regression formulas can be used in both phases of intermittent aeration.

iBOB does not require an ion-exchange membrane or protection of the anode against exposure to oxygen. The biosensor can be readily set up at existing aeration tanks and water environments. The biosensor displayed the accurate monitoring of BOD5 with R2 values (>0.9) in both the aerating and non-aerating phases. Moreover, the anode of the biosensor did not require any maintenance (e.g. washing), even though the anode was completely covered with SS. On the other hand, when a DO or ORP sensor is continuously used in aeration tanks, the sensor signal tends to be unstable because of membrane fouling with SS in the absence of automatic washing of the probe. In contrast, not only does the anode of iBOB require less maintenance, the adhesion of SS to the anode is beneficial in that it leads to an anaerobic environment on the interior of the attached anode. The adhesion of SS to the reference electrode was very limited because the air bubbles from the diffuser tube washed away the SS in the aerating phase. In pH and OPR probes, the key components (H+-absorbing Li-glass membrane and metal electrode, respectively) for the measurements are directly exposed to the solution measured; thus, impurities in wastewater are liable to adhere on the components. However, in the Ag/AgCl reference electrode of the present study, the key component for measurement is not exposed to the outer solution, and the inner solution is simply separated from the outer solution through a non-selective junction filter. In this study, the filter of the reference electrode appeared to be clean as a result of washing with air bubbles throughout the experiment, and no biofilm formation was observed on the surface. The inside of the reference electrode was filled with 3.3 M KCl, and the salt was capable of leaking from the filter very slowly. Biofilms would therefore not form on the surface of the filter because of the high salinity of KCl. In addition, the reference electrode used in this study was of the double-junction type, which has an extra barrier to protect the interior Ag. As compared to single-junction electrodes, double-junction electrodes are more resistant to poisoning of Ag by infiltration of impurities such as protein and sulfides, and thus have a longer lifetime. The use of a double-junction electrode would contribute to the accurate BOD sensing of iBOB.

The development of in situ and real-time BOD monitoring techniques that can be directly applied to aeration tanks will have a considerable impact on process control in wastewater treatment situations, especially for the automatic control of aeration intensity in small-scale treatment plants for on-site purification, such as is necessary at livestock farms and food processing factories. In summary, the iBOB biosensor has the following potential practical applications: (i) the discharge of inadequately treated wastewater with high BOD concentrations to surrounding water environments can be prevented using a signal from the biosensor. (ii) As aeration consumes considerable electrical power in wastewater treatments, the biosensor produces a stop signal when the BOD concentration of wastewater decreases to an effluent standard to avoid excess aeration and decrease associated costs. (iii) The importance of nitrogen removal from wastewater is currently increasing to protect water environments from further eutrophication27. The control of the ratio of BOD/nitrogen is critical in the nitrogen removal by the intermittent aeration process2. This is especially true for wastewater with a low BOD/nitrogen ratio28, such as in faeces/urine-separated livestock wastewater and the effluence from biogas plants, as excess aeration depletes BOD as an electron donor, which is required for biological denitrification. Using a signal from iBOB, the ratio of BOD/nitrogen could be properly maintained by controlling the aeration duration in the intermittent aeration process. (iv) The unique configuration of the open-type anode allows the setup of the iBOB to be easily tailored to various water environments, such as ponds and streams. In conclusion, this biosensor will be instrumental in monitoring the pollution of vital water resources. Further studies, such as the evaluation of regression formulas for various kinds of wastewaters and natural waters, are needed to fully document the practical applications of the iBOB biosensor.

Conclusions

We designed a novel BES-based biosensor, equipped with an open-type anode, for the in situ monitoring of BOD5 under conditions of intermittent aeration. The iBOB biosensor generates current in both aerating and non-aerating phases of intermittent aeration, exhibiting a high correlation (R2 > 0.9) with BOD5. The biosensor can be easily set up in existing aeration tanks as well as in natural environments. The iBOB biosensor will be useful in myriad applications, most notably for the automatic control of aeration intensity.

Methods

Operation of the intermittent aeration reactor

The reactor was a cuboidal-shaped pilot-scale tank with an interior volume of 1.2 m3. The livestock wastewater, including manure and rinse water, was collected from the cattle and swine barns at Institute of Livestock and Grassland Science (Tsukuba-city, Ibaraki, Japan). Wastewater was sieved using a screw press, and the filtrate was periodically pumped to the tank at a flow rate of 33 L/min for 2 min every 8 h, corresponding to the HRT of 4 days. The water level was maintained at 800 L by overflow control, and the water temperature was kept at 22 °C by inserting two electrical heaters (500 kW) into the tank. The tank was intermittently aerated via diffuser tubes by using an XP30 air-pump (Techno Takatsuki, Osaka, Japan) at a flow rate of 3 m3/m3·h in a cycle of 1 h of aeration and 2 h of non-aeration for a week from the beginning of operation, and thereafter, the aeration cycle was changed to 2 h of aeration and 2 h of non-aeration. After running under this condition for several weeks, the reactor was operated at different HRTs and aeration cycles to obtain various concentrations of BOD5.

Development of the iBOB biosensor

The anode (also called the working electrode) consisted of carbon-fibre bundles (26.7 g), and formed a tree-shaped structure with a stem (70 cm) and 20 branches (20 cm). Each branch contained 144,000 polyacrylonitrile-based carbon fibres with a diameter of 7 μm (Mitsubishi Rayon, Tokyo, Japan). Two anodes were hung in the aeration tank, and were connected to the potentiostat HAL-3001A (Hokuto Denko, Tokyo, Japan) using a copper wire. An Ag/AgCl-reference electrode of a double-junction type with porous ceramic filters (International Chemistry, Chiba, Japan) and a counter electrode made of stainless-steel mesh (60 mesh, SUS304, 90 cm × 80 cm × 0.1 cm in size) were also connected to the potentiostat. The anode potential was controlled at −0.2 V (vs. Ag/AgCl) with the potentiostat throughout the duration of the experiments. Current generation was recorded every 10 minutes with a data logger ZR-RX45 (OMRON, Kyoto, Japan). DO, pH, and ORP were monitored using the YUSB-01DO, YUSB-01PH, and YUSB-01OR indicators, respectively (DKK-TOA Yamagata, Yamagata, Japan).

BOD5 measurement and chemical analysis

To determine BOD5, treated wastewater was sampled from the aeration tank once per a day. BOD5 was measured at 20 °C via a respirometric method by using a BODTrackTM apparatus equipped with a pressure sensor (Hach, Düsseldorf, Germany), in the presence of a nitrification inhibitor for 5 days. Concentrations of NH4-N, NO2-N, and NO3-N were determined using an ion chromatograph, IC-2010 (Tosoh, Tokyo, Japan). Total nitrogen was analysed with a total carbon and nitrogen analyser, TOC-V CSN (Shimadzu, Kyoto, Japan).

Analysis of community structure

High-throughput sequencing was performed via the MiSeq Illumina sequencing platform (Illumina Inc., CA, USA) using the region from V3 to V4 from the 16S rRNA gene29. A part of the carbon-fibre anode was cut off, and was roughly washed with distilled water. The bacteria present in the excised anode were regarded as the WA fraction. Subsequently, the excised anode was further washed with distilled water, until the visible SS attached to the anodic surface completely disappeared. The bacteria binding to the strongly washed anode were regarded as the AB fraction. The wastewater in the tank was sampled, and was centrifuged at 1,000 g for 10 min. The precipitate was washed with distilled water, and the bacteria in the precipitate were regarded as the PC fraction. Genomes were extracted from the fractions using an UltraClean™ Soil DNA Isolation kit (Mo Bio Laboratories, CA, USA). Libraries were constructed in a two-step PCR using the primers, including the Illumina overhang adapter sequences, according to the manufacturer’s instructions. The libraries were sequenced on 300PE MiSeq run, and the read sequences were clustered into OTUs using the Uclust method30 at a similarity threshold of 97% using QIIME software31. Representative sequences were aligned using PyNAST32, and the taxonomic classification and alpha diversity indices were computed with QIIME. The phylogenetic tree, combined with the heat map, was calculated by the unweighted pair-group method using arithmetic averages (UPGMA) using MEGA433.

Additional Information

How to cite this article: Yamashita, T. et al. A novel open-type biosensor for the in-situ monitoring of biochemical oxygen demand in an aerobic environment. Sci. Rep. 6, 38552; doi: 10.1038/srep38552 (2016).

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Material

Supplementary Information
srep38552-s1.pdf (64.3KB, pdf)

Acknowledgments

We thank Ms. Kyoko Hirano for her assistance with the experiments. This study was supported by grants from the Project of the NARO Bio-oriented Technology Research Advancement Institution under a special scheme project on Regional Development Strategy (number 16784619) and the Japan Society for the Promotion of Science (JSPS) under KAKENHI (number JP26850177 and JP15K07820).

Footnotes

Author Contributions T.Y., N.O., and M.I. analysed the biosensor. H.K., H.S., Y.K., and H.Y. characterised the communities. H.Y. designed the research, and wrote the paper.

References

  1. Abrevaya X. C., Sacco N. J., Bonetto M. C., Hilding-Ohlsson A. & Corton E. Analytical applications of microbial fuel cells. Part I: Biochemical oxygen demand. Biosens. Bioelectron. 63, 580–590, doi: 10.1016/j.bios.2014.04.034 (2015). [DOI] [PubMed] [Google Scholar]
  2. Osada T., Haga K. & Harada Y. Removal of nitrogen and phosphorus from swine waste-water by the activated-sludge units with the intermittent aeration process. Water Res. 25, 1377–1388, doi: 10.1016/0043-1354(91)90116-8 (1991). [DOI] [Google Scholar]
  3. Jouanneau S. et al. Methods for assessing biochemical oxygen demand (BOD): A review. Water Res. 49, 62–82, doi: 10.1016/j.watres.2013.10.066 (2014). [DOI] [PubMed] [Google Scholar]
  4. Vernimmen A. P., Henken E. R. & Lamb J. C. A short-term biochemical oxygen demand test. J. Water Pollut. Control Fed. 39, 1006–1020 (1967). [PubMed] [Google Scholar]
  5. Liu J., Olsson G. & Mattiasson B. Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process. Part II: Instrumentation of integrated flow injection analysis (FIA) system for BODst estimation. Biosens. Bioelectron. 20, 571–578, doi: 10.1016/j.bios.2004.03.007 (2004). [DOI] [PubMed] [Google Scholar]
  6. Liu J., Olsson G. & Mattiasson B. Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process Part 1. A novel design of BOD biosensor for easy renewal of bio-receptor. Biosens. Bioelectron. 20, 562–570, doi: 10.1016/j.bios.2004.03.008 (2004). [DOI] [PubMed] [Google Scholar]
  7. Karube I., Matsunaga T., Mitsuda S. & Suzuki S. Microbial electrode sensors. Biotechnol. Bioeng. 19, 1535–1547, doi: 10.1002/bit.260191010 (1977). [DOI] [PubMed] [Google Scholar]
  8. Chee G. J., Nomura Y. & Karube I. Biosensor for the estimation of low biochemical oxygen demand. Anal. Chim. Acta 379, 185–191, doi: 10.1016/s0003-2670(98)00680-1 (1999). [DOI] [Google Scholar]
  9. Qian Z. R. & Tan T. C. Response characteristics of a dead-cell BOD sensor. Water Res. 32, 801–807, doi: 10.1016/s0043-1354(97)00278-9 (1998). [DOI] [Google Scholar]
  10. Sakaguchi T. et al. A rapid BOD sensing system using luminescent recombinants of Escherichia coli. Biosens. Bioelectron. 19, 115–121, doi: 10.1016/s0956-5663(03)00170-2 (2003). [DOI] [PubMed] [Google Scholar]
  11. Dobbs R. A., Dean R. B. & Wise R. H. Use of ultraviolet absorbance for monitoring total organic carbon content of water and wastewater. Water Res. 6, 1173–1180, doi: 10.1016/0043-1354(72)90017-6 (1972). [DOI] [Google Scholar]
  12. Reynolds D. M. & Ahmad S. R. Rapid and direct determination of wastewater BOD values using a fluorescence technique. Water Res. 31, 2012–2018, doi: 10.1016/s0043-1354(97)00015-8 (1997). [DOI] [Google Scholar]
  13. Vanrolleghem P. A. & Lee D. S. On-line monitoring equipment for wastewater treatment processes: state of the art. Water Sci. Technol. 47, 1–34 (2003). [PubMed] [Google Scholar]
  14. Wang H., Luo H., Fallgren P. H., Jin S. & Ren Z. J. Bioelectrochemical system platform for sustainable environmental remediation and energy generation. Biotechnol. Adv. 33, 317–334, doi: 10.1016/j.biotechadv.2015.04.003 (2015). [DOI] [PubMed] [Google Scholar]
  15. Liu H., Ramnarayanan R. & Logan B. E. Production of electricity during wastewater treatment using a single chamber microbial fuel cell. Environ Sci Technol 38, 2281–2285, doi: 10.1021/es034923g (2004). [DOI] [PubMed] [Google Scholar]
  16. Call D. & Logan B. E. Hydrogen production in a single chamber microbial electrolysis cell lacking a membrane. Environ. Sci. Technol. 42, 3401–3406, doi: 10.1021/es8001822 (2008). [DOI] [PubMed] [Google Scholar]
  17. Clauwaert P. et al. Minimizing losses in bio-electrochemical systems: the road to applications. Appl. Microbiol. Biotechnol. 79, 901–913, doi: 10.1007/s00253-008-1522-2 (2008). [DOI] [PubMed] [Google Scholar]
  18. Lovley D. R. et al. Geobacter metallireducens gen. nov. sp. nov., a microorganism capable of coupling the complete oxidation of organic compounds to the reduction of iron and other metals. Arch. Microbiol. 159, 336–344, doi: 10.1007/bf00290916 (1993). [DOI] [PubMed] [Google Scholar]
  19. Bond D. R. & Lovley D. R. Electricity production by Geobacter sulfurreducens attached to electrodes. Appl. Environ. Microbiol. 69, 1548–1555, doi: 10.1128/aem.69.3.1548-1555.2003 (2003). [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Kim B. H., Chang I. S., Gil G. C., Park H. S. & Kim H. J. Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell. Biotechnol. Lett 25, 541–545, doi: 10.1023/a:1022891231369 (2003). [DOI] [PubMed] [Google Scholar]
  21. Chang I. S. et al. Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor. Biosens. Bioelectron. 19, 607–613, doi: 10.1016/s0956-5663(03)00272-0 (2004). [DOI] [PubMed] [Google Scholar]
  22. Di Lorenzo M., Curtis T. P., Head I. M. & Scott K. A single-chamber microbial fuel cell as a biosensor for wastewaters. Water Res. 43, 3145–3154, doi: 10.1016/j.watres.2009.01.005 (2009). [DOI] [PubMed] [Google Scholar]
  23. Modin O. & Wilen B.-M. A novel bioelectrochemical BOD sensor operating with voltage input. Water Res. 46, 6113–6120, doi: 10.1016/j.watres.2012.08.042 (2012). [DOI] [PubMed] [Google Scholar]
  24. Zhang Y. & Angelidaki I. Submersible Microbial Fuel Cell Sensor for Monitoring Microbial Activity and BOD in Groundwater: Focusing on Impact of Anodic Biofilm on Sensor Applicability. Biotechnol. Bioeng. 108, 2339–2347, doi: 10.1002/bit.23204 (2011). [DOI] [PubMed] [Google Scholar]
  25. Rinke C. et al. Insights into the phylogeny and coding potential of microbial dark matter. Nature 499, 431–437, doi: 10.1038/nature12352 (2013). [DOI] [PubMed] [Google Scholar]
  26. Mulder A., Vandegraaf A. A., Robertson L. A. & Kuenen J. G. Anaerobic ammonium oxidation discovered in a denitrifying fluidized-bed reactor. FEMS Microbiol. Ecol. 16, 177–183, doi: 10.1111/j.1574-6941.1995.tb00281.x (1995). [DOI] [Google Scholar]
  27. Cole M. L. et al. Assessment of a delta N-15 isotopic method to indicate anthropogenic eutrophication in aquatic ecosystems. J. Environ. Qual. 33, 124–132, doi: 10.2134/jeq2004.1240 (2004). [DOI] [PubMed] [Google Scholar]
  28. Fan J. et al. Nitrogen removal in intermittently aerated vertical flow constructed wetlands: Impact of influent COD/N ratios. Bioresour. Technol. 143, 461–466, doi: 10.1016/j.biortech.2013.06.038 (2013). [DOI] [PubMed] [Google Scholar]
  29. Kozich J. J., Westcott S. L., Baxter N. T., Highlander S. K. & Schloss P. D. Development of a dual-Index sequencing strategy and curation pipeline for analyzing amplicon sequence data on the MiSeq Illumina sequencing platform. Appl. Environ. Microbiol. 79, 5112–5120, doi: 10.1128/aem.01043-13 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Edgar R. C. Search and clustering orders of magnitude faster than BLAST. Bioinformatics 26, 2460–2461, doi: 10.1093/bioinformatics/btq461 (2010). [DOI] [PubMed] [Google Scholar]
  31. Caporaso J. G. et al. QIIME allows analysis of high-throughput community sequencing data. Nat. Methods 7, 335–336, doi: 10.1038/nmeth.f.303 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Caporaso J. G. et al. PyNAST: a flexible tool for aligning sequences to a template alignment. Bioinformatics 26, 266–267, doi: 10.1093/bioinformatics/btp636 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Tamura K., Dudley J., Nei M. & Kumar S. MEGA4: Molecular evolutionary genetics analysis (MEGA) software version 4.0. Mol. Biol. Evol. 24, 1596–1599, doi: 10.1093/molbev/msm092 (2007). [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information
srep38552-s1.pdf (64.3KB, pdf)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES