Abstract
Establishing the mineral content distribution in highly mineralized tissues, such as bones and teeth, is fundamental in understanding a variety of structural questions ranging from studies of the mechanical properties to improved pathological investigations. However, non-destructive, volumetric and quantitative density measurements of mineralized samples, some of which may extend several mm in size, remain challenging. Here, we demonstrate the potential of grating-based x-ray phase tomography to gain insight into the three-dimensional mass density distribution of tooth tissues in a non-destructive way and with a sensitivity of 85 mg/cm3. Density gradients of 13 − 19% over 1 − 2 mm within typical samples are detected, and local variations in density of 0.4 g/cm3 on a length scale of 0.1 mm are revealed. This method proves to be an excellent quantitative tool for investigations of subtle differences in mineral content of mineralized tissues that can change following treatment or during ageing and healing.
Introduction
Highly mineralized tissues, such as teeth and bones, underwent natural selection during millions of years of evolution, hence they are very well adapted to match their specific mechanical-biological function. Moreover, typically they perform better than any implants and are more durable. However, because of their complicated, hierarchical organization, these tissues and the dynamics of mineral content change are far from being completely understood. Bone and dentine in teeth tissues contain a matrix of mineralized collagen fibers. Knowledge about the precise mineral content in these tissues is important for understanding their properties, and is also an indicator for the state of the tissue pathology [1, 2].
Teeth consist of three mineralized tissues known as enamel, dentine, and cementum. The dentine matrix forms the bulk of the tooth and is composed of 45 − 50 vol% (volume percentage) inorganic material (apatite), 30 − 35 vol% organic material (mainly type I collagen) and 4 − 20 vol% fluid (water). It consists of a system of dentinal tubules surrounded by highly mineralized collagen-free peri-tubular dentine and embedded in the intra-tubular dentine. The tubules traverse the structure from the pulp cavity to the region just below the dentine-enamel junction (DEJ). Tubule density, size and orientation vary within the tooth. The diameter of the tubules increases from the DEJ (1 μm) to the pulp chamber (3 μm) and the number of tubules per mm2 increases from about 19000 to 75000 [3–5].
Enamel covers the crown of teeth and is the hardest substance in a vertebrate, with hardness values between that of iron and carbon steel [6]. It is dominated by the mineral phase, which is about 95 wt% (percentage by weight). Only about 1 wt% is organic matrix and 4 wt% is water [7]. However, these are only mean values and a variety of values for enamel compositions can be found in literature [8–11].
Often in studies, it is important to precisely quantify the mineral content or mass density of tooth tissues in three dimensions and on relatively large specimens, e.g. to examine differences between healthy and diseased parts of tooth [12–14]. Several methods, like backscattered electron microscopy [15], x-ray ptychography [16] and x-ray absorption microtomography [14] are used for measuring tooth density. However, some of them provide only two-dimensional information or the sample size is limited to a few micrometers or needs destructive sample preparation. For example, backscattered electron microscopy imaging provides quantitative mineral density values with nanometer resolution. However, the approach is limited to those surfaces exposed during the preparation process and does not provide any depth or three dimensional information [15]. Hard x-rays have a higher penetration power than electrons, and different schemes have been proposed to obtain three-dimensional information of mineralized tissues. X-ray absorption microtomography provides volumetric data without the need to slice the sample [9]. However, the sensitivity provided by this method is inherently limited, even when using the highly-brilliant beam available at large-scale synchrotron facilities. Moreover, access to electron density requires a series of assumptions on tissue composition [17]. Phase-contrast x-ray imaging techniques are known to yield higher sensitivity three-dimensional electron density data, down to nanometer resolution [16, 18]. Highly accurate measurement of mineral content in teeth has been demonstrated with x-ray ptychography [16], while magnified x-ray tomography has revealed the ultrastructure of bone with high detail [18]. However, the sample sizes investigated by these methods is often limited to the micrometer range.
Here, we use a technique termed x-ray grating interferometry, previously validated and widely used on a variety of biological tissues (see [19–22]), which allows one to measure quantitatively and accurately the mass density and electron density of different samples (see [19, 23–26]). In this study, teeth samples were selected as an example for one of the most important mineralized biomaterials to demonstrate the potential and application of x-ray grating interferometry in order to discriminate mineralized tissue of different densities. We show that this method, based on phase contrast, allows measurements of the mineral content in three-dimensions on extended samples with an unprecedented spatial sensitivity and a resolution and sample size that allow in-vitro investigation of clinically relevant questions [14].
Materials and Methods
Tooth samples
Five extracted human teeth (incisor, canine, premolar, 2 × molar) and one pig incisor were used in this study (see Table 1). The pig tooth was obtained from a local butcher, extracted from the discarded jaw-bones after the 4 year old commercial-meat animal was slaughtered. A large warn-down but largely unaffected tooth was selected for this study. All human teeth were obtained from patients undergoing routine dental treatment unrelated to this study, with written informed consent, following an ethics-approved protocol by the Ethical Review Committee of the Charité—Universitätsmedizin Berlin (EA4/002/09). The single samples have a roughly cylindrical shape with diameters varying from 1 to 3 mm and heights varying from 2 to 6 mm, and are glued on an aluminium support for the measurements, see Fig 1A. This sample size was chosen, on the one hand, to provide reasonably large volumes of different regions (enamel / dentin) of several teeth. On the other hand, the size had to be adapted to the experimental constraints, in particular the field of view and the amount of synchrotron beamtime allocated for this experiment.
Table 1. Description of the investigated samples.
E | lower anterior (from pig) |
G | upper 1st molar, bucco gengival crown region |
N | upper canine, palatal aspect, crown-root junction |
R | upper canine, incisal enamel and dentine |
S | lower premolar, mid buccal crown |
U | upper 3rd molar, palatal root tip |
X-ray grating interferometry
The working principles of x-ray grating interferometry (XGI) are described in detail in Refs. [27, 28] and briefly explained below. A standard XGI consists of two gratings: a phase grating (G1) and an absorption analyzer grating (G2). At well-defined propagation distances, called fractional Talbot distances [29], the sinusoidal interference pattern generated by G1 has maximum contrast. The interactions of the x-rays with a sample, usually placed upstream of G1, distort this interference pattern; absorption, phase-shift and small angle x-ray scattering from unresolvable features (dark-field) affect the shape of this pattern independently from each other in different ways. This distorted pattern is compared to a reference pattern recorded without the sample in the beam. In this way, it is possible to retrieve the absorption, differential phase (proportional to the refraction angle), and dark-field images of the investigated object (see Ref. [28, 30]).
If maintaining a relatively large field of view while optimizing phase sensitivity is desired, the period of the interference pattern generated by G1 often becomes too small to be resolved by the detector. Hence a second grating G2, which has the same period as the interference pattern, is used in the analysis. G2 is placed directly in front of the detector at a fractional Talbot distance d from G1. The analysis of the interference pattern is often performed with the phase-stepping technique. A series of images (more than two) is recorded for different transverse positions of G1 (in Fig 2, G1 is moved along the horizontal direction perpendicular to the optical axis) and the desired image signals are extracted with a pixel-wise routine based on Fourier analysis [30].
In a tomographic scan, the sample is rotated around the y—axis and hundreds of phase-stepping scans are performed at evenly-spaced viewing angles of the sample. The tomographic reconstruction using absorption and refraction angle projections, usually performed with the filtered-back projection (FBP) algorithm, yields the three-dimensional distribution of the full complexed-value refractive index: n(x, y, z) = 1 − δ(x, y, z) + ıβ(x, y, z), where the real part δ(x, y, z) is obtained from the phase reconstruction, and the imaginary part β(x, y, z), proportional to the linear attenuation coefficient μ(x, y, z) = 4πβ(x, y, z)/λ, where λ is the wavelength of the radiation, is computed from the absorption projections [31]. To account for the differential nature of the refraction angle projections, a modified filter in the FBP algorithm is used to obtain the phase tomogram. Moreover, the dark-field volume can also be extracted with a similar procedure from the same dataset [32]. Since the three signals are extracted from the same dataset, the corresponding volumes are inherently registered. In the following, we mainly use the information from the phase and absorption volumes, while the potential of the dark-field signal is discussed in the S1 Appendix.
From refractive index to mass density
When the measurement is performed with an x-ray energy far from the absorption edges of the materials in the sample, the phase volume gives access to the electron density ρe(x, y, z) within the investigated specimen [33]:
(1) |
where r0 is the classical electron radius. The electron density can be transformed to mass density ρm [34]
(2) |
where A is the atomic mass, Z the atomic number and NA the Avogadro constant. For materials poor in hydrogen such as teeth the approximation A/Z = 2 g/mol is valid [35]. This gives
(3) |
Thus, by combining Eqs 1 and 3, the mass density is related to the refractive index by the following relation:
(4) |
Experimental setup
The experiment was performed at the ID19 beamline of the European Synchrotron Radiation Facility (ESRF), Grenoble, France [36]. Setups for grating-based X-ray phase-contrast tomography are already in use at a couple of facilities (e. g. DESY, PSI, Spring8) and could be built up at any of the available synchrotron facilities or even at laboratory sources.
A picture of the two-grating interferometer located at the ID19 beamline is shown in Fig 1B. A Si (111) double crystal monochromator delivered a monochromatic beam (spectral range Δλ/λ ≈ 10−4) of an x-ray energy of 53 keV (0.23 Å). In this setup, a nickel phase grating (G1) with a period of 2.4 μm and a height of 35 μm was used in combination with an analyzer grating G2 with a period of 2.4 μm and gold structures with a height of 100 μm. Both gratings were produced by the Karlsruhe Institute for Technology (KIT), Karlsruhe, Germany with x-ray lithography [37]. The inter-grating distance was 37 cm, which corresponds to the 3rd fractional Talbot distance at the working energy. The detector was a scintillator-based, lens-coupled CCD camera, with a 10 μm Gadox (Gd2O2S) scintillator and an effective pixel size of 7.5 μm.
The average visibility of the sinusoidal phase-stepping curve without the sample in the beam can be used to evaluate the performance of the interferometer. It was obtained from a region of 1.5 × 1.5 mm2 at the centre of the field of view, and the visibility in one pixel was defined as V = (Imax − Imin)/(Imax + Imin), where Imin is the minimum and Imax is the maximum intensity value of the phase-stepping curve without the sample. The visibility value of 16% suggests a good performance of the instrument, also considering the relatively high x-ray energy which reduces the absorption in the analyzer grating.
For the tomographic measurement, the specimen was immersed in water to reduce artifacts arising from the strong refraction at the sample-air interface [19]. Furthermore, simulations showed that the influence of phase-wrapping artifacts on the delta values are negligible at the employed energy of 53 keV (data is not explicitly shown here). A series of 800 phase-stepping scans were collected over a sample rotation of 180 degrees at equidistant angles. The phase stepping was performed over one grating period in four evenly-spaced steps. The acquisition time per frame was 2 s.
Results & Discussion
The three-dimensional distributions of the mass density (from the phase volume) and of the linear attenuation coefficient (from the absorption volume) of all samples are obtained simultaneously with the procedure described above. The measured mass density describes the whole tissue including mineral and organic components inside the biocomposites.
An example of the same sagittal slice extracted from the phase and absorption data of sample G is shown in Fig 3A and 3C respectively. The top of the sample is taken from a tooth segment near the DEJ, while the lower part of the sample is closer to the pulp. Both absorption and phase signals allow clear separation of the dentine from the surrounding water. However, the visual comparison of these slices immediately highlights the higher quality of the phase image. This is confirmed by the two-dimensional (2D) histogram analysis of the full volumes computed as reported in the S2 Appendix. The 2D histograms are displayed in Fig 3B (phase), and Fig 3D (absorption). The vertical red lines in the 2D histograms are formed by water (straight line at the left used for calibration) and dentine (line at the right). The measured values of about 2.0 g/cm3 for mass density and of about 0.8 cm−1 for the linear attenuation coefficient are in agreement with previous reports (see [12, 38]). The width of the water peak in the histograms is related to the sensitivity of the measurement. If the data were noise free, all the voxels displaying water would yield the same refractive index value and thus the peak would be infinitely narrow. However, noise and artifacts in the data cause a broadening of the peak. This broadening is more pronounced in the absorption than in the phase data which confirms the higher sensitivity of the latter. Here, the sensitivity of the phase and absorption measurements is estimated to be the full width at half maximum of the water peak, which is 0.38 cm−1 for the absorption volume and 85 mg/cm3 for the mass density derived from the phase volume. The inclination of the dentine peaks, which can be observed with both contrast modalities, is caused by a refractive index gradient in the axial direction from pulp to DEJ. While this gradient is well defined in the axial direction, the S2 Appendix shows that the properties of the sample do not significantly change in the orthogonal directions. The origin and quantification of the increase in density from pulp to enamel will be further discussed in the following.
Density gradient
All examined dentine samples exhibit a well-defined refractive-index gradient in the axial direction. In particular, both the imaginary and real parts of the refractive index (mass density and linear attenuation coefficient) increase from pulp to enamel. Further examples are shown in Fig 4 (samples S and E). This change in density is a known property of dentine and it is explained to be related to a change of both tubule density and mineral content. The tubule density decreases and the mineral content increases from pulp to enamel. Among other techniques, this density variation has previously been quantified using backscattered electron-scanning imaging on chosen slices and with synchrotron radiation absorption-contrast tomography (see [11, 39]).
Here, to evaluate the change in mass density over the examined samples, the densities are calculated for small volumes of interest (VOIs) of 60 × 60 × 10 pixels (450 × 450 × 75 μm3) at different heights of the samples. Mass density variations in the range of 13 − 19%, consistent with previous observations, are found over distances of 1 − 2 mm in the investigated samples and summarized in Table 2.
Table 2. Mass density variation in dentine.
sample | mass density [g/cm3] | distance [mm] |
---|---|---|
E | 1.77 ± 0.02–2.06 ± 0.03 | 2.0 |
G | 1.79 ± 0.02–2.12 ± 0.03 | 1.8 |
N | 1.93 ± 0.02–2.10 ± 0.03 | 1.0 |
R | 1.95 ± 0.02–2.08 ± 0.03 | 1.0 |
S | 1.83 ± 0.03–2.08 ± 0.04 | 1.3 |
U | 1.80 ± 0.02–1.99 ± 0.03 | 1.0 |
Values are calculated for small VOIs at different heights of the samples. The error takes into account (i) the standard deviation of the gray levels in the VOI and (ii) the reading error in the inter-grating distance estimated to be 0.5 cm. The last column gives the distance over which the density change appears.
Local density variation
In addition to the gradients discussed above, local mass density variations could be detected based on the high-sensitivity data provided by the phase signal. An example, probably due to to the presence of blind tracts (areas in dentine which are characterized by degenerated odontoblastic processes—dead tracts—and filled with mineral), is shown in Fig 5. Panel A displays a sagittal slice extracted from the phase volume of sample S and Fig 5B the same sagittal slice from the absorption volume. Panels C and D show enlarged details of these slices. While regions with higher density are barely visible in the absorption reconstruction, these areas are clearly revealed in the phase data and indicated with arrows in Fig 5A. The difference in density between high-density regions and their surroundings has been estimated using the regions of interest (ROIs) indicated by yellow and green rectangles in Fig 5C with a size of 75 × 150 μm2. The values are 2.07±0.01 g/cm3 for the higher density region and 1.60±0.01 g/cm3 for the outer area, where the errors are determined by the standard deviation within the ROIs. This value yields a contrast-to-noise ratio of 33 computed as proposed in Ref. [19]. The higher sensitivity of the phase signal is also visualized in the histogram analysis shown in Fig 5E and 5F. The histogram of the phase data clearly shows three peaks further described in the caption of the figure, while the absorption data is not sensitive enough to separate such variations in tissue composition.
Dentine versus enamel
Besides dentine, two out of the six samples measured in this study also contained enamel. In the following, the densities of dentine and enamel in our specimens are compared. The mass density values for 102 volumes of interest (VOIs) in dentine (60 × 60 × 10 pixels each) from five human tooth pieces and 27 VOIs in enamel (45 × 45 × 10 pixels each) from two human tooth pieces are computed and displayed in the histogram in Fig 6 [35]. The density values for dentine span 1.79±0.02 g/cm3 to 2.12±0.03 g/cm3, while the values for enamel span 2.61±0.04 g/cm3 to 2.77±0.04 g/cm3. The values for dentine are in good agreement with values previously reported: Schwass et al., using a microcomputed tomography system, measured a density of 1.97 g/cm3 [40], while Manly et al. using buoyancy experiments with liquids of different densities observed a value of 2.35 g/cm3 [38]. Moreover, Manly et al. reported that the root dentine is less dense than the average value of the whole dentine as observed in this study; their average value for the former was 1.94 g/cm3 compared to 2.03 g/cm3 obtained for the crown region.
The reported mass densities for enamel range from 2.6 g/cm3 [38] to 3.0 g/cm3 [41]. The average value obtained in this study fits in this range and is in good agreement with the value of 2.72 g/cm3 reported by Schwass et al. [40]. The fact that our measurements provide densities in the lower range of the values reported in literature might be due to the fact that we considered VOIs close to the DEJ where the density is known to be lower [41–43].
Conclusions
We have shown that x-ray grating-based tomography is a valuable tool for three-dimensional quantitative studies on mineralized samples. The reliability of the mass density values obtained with this method is confirmed through comparison with published results obtained with independent techniques.
Compared to other phase-sensitive methods, the object size that can be investigated with x-ray grating interferometry is relatively large and may even extend to a few centimeters. Thus, differently than phase-sensitive nanotomographic methods, entire teeth or bones can be imaged in one scan which requires only a few hours. The mass density values obtained in the reconstructed volume are averaged over the voxel size which may reach tens of micrometers in size.
These characteristics and the ultra-high sensitivity of this technique make it a valuable tool for investigating the density distribution and local density fluctuations in both healthy and pathological bone or tooth specimens. In this manner, x-ray grating-based phase tomography can provide invaluable insight into formation, mineralization dynamics, ageing and pathology of mineralized tissues.
Supporting Information
Acknowledgments
We acknowledge Hans Deyhle (BMC, University of Basel) for helpful insight in interpreting the tooth images. We acknowledge financial support through the DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP), the DFG Gottfried Wilhelm Leibniz program, and the DFG funding PZ through SPP1420. RG gratefully acknowledges the ESRF for a 6 month hosting, and the E17 group of TU Munich for fruitful discussions and generous support.
Data Availability
The raw data underlying the results of this report is stored in the public repository figshare (https://figshare.com/articles/part01_zip/4224228).
Funding Statement
FP was funded by DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP), the DFG Gottfried Wilhelm Leibniz program, and PZ was funded by the DFG funding through SPP1420. The funder (Diamond Light Source) provided support in the form of salaries for authors [IZ], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. This does not alter our adherence to PLOS ONE policies on sharing data and materials.
References
- 1. Weiner S, Wagner HD. The Material Bone: Structure-Mechanical Function Relations. Ann Rev Mater Sci. 1998;28:271–289. 10.1146/annurev.matsci.28.1.271 [DOI] [Google Scholar]
- 2. Roschger P, Paschalis EP, Fratzl P, Klaushofer K. Bone mineralization density distribution in health and disease. Bone. 2008;42:456–466. 10.1016/j.bone.2007.10.021 [DOI] [PubMed] [Google Scholar]
- 3. Garberoglio R, Brännström M. Scanning electron microscopic investigation of human dentinal tubules. J Oral Biol. 1976;21:355–362. [DOI] [PubMed] [Google Scholar]
- 4. Pashley DH. Dentin: A dynamic substrate—A review. Scanning Microscopy. 1989;3(1):161–176. [PubMed] [Google Scholar]
- 5. Arola DD, Reprogel RK. Tubule orientation and the fatigue strength of human dentin. Biomaterials. 2006;27(9):2131–2140. 10.1016/j.biomaterials.2005.10.005 [DOI] [PubMed] [Google Scholar]
- 6. Bartlett JD. Dental Enamel Development: Proteinases and Their Enamel Matrix Substrates. ISRN Dentistry. 2013;2013:684607 10.1155/2013/684607 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Bäuerlein E. Handbook of Biomineralization: Biological Aspects and Structure Formation. Weinheim, Germany: Wiley-VCH; 2007. [Google Scholar]
- 8. Elliott JC, Wong FS, Anderson P, Davis GR, Dowker SEP. Determination of mineral concentration in dental enamel from x-ray attenuation measurements. Connect Tissue Res. 1998;38:61–72. 10.3109/03008209809017022 [DOI] [PubMed] [Google Scholar]
- 9. Schmitz JE, Teepe JD, Hu Y, Smith CE, Fajardo RJ, Chun YHP. Estimating Mineral Changes in Enamel Formation by Ashing/BSE and MicroCT. J Dent Res. 2014;93(3):256–262. 10.1177/0022034513520548 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Cuy JL, Mann AB, Livi KJ, Teaford MF, Weihs TP. Nanoindentation mapping of the mechanical properties of human molar tooth enamel. Arch Oral Bio. 2002;47:281–291. [DOI] [PubMed] [Google Scholar]
- 11. Angker L, Nockolds C, Swain MV, Kilpatrick N. Qantitative analysis of the mineral content of sound and carious primary dentine using BSE imaging. J Oral Bio. 2004;49:99–107. [DOI] [PubMed] [Google Scholar]
- 12. Maerten A, Fratzl P, Paris O, Zaslansky P. On the mineral in collagen of human crown dentine. Biomaterials. 2010;31:5479–5490. 10.1016/j.biomaterials.2010.03.030 [DOI] [PubMed] [Google Scholar]
- 13. Davis GR, Evershed ANZ, Mills D. Quantitative high contrast x-ray microtomography for dental research. J Dent. 2013;41:475–482. 10.1016/j.jdent.2013.01.010 [DOI] [PubMed] [Google Scholar]
- 14. Deyhle H, Dziadowiec I, Kind L, Thalmann P, Schulz G, Müller B. Mineralization of Early Stage Carious Lesions In Vitro—A Quantitative Approach. Dent J. 2015;3:111–122. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Boyes ED. On Low Voltage Scanning Electron Microscopy and Chemical Microanalysis. Microsc Microanal. 2000;6:307–316. [DOI] [PubMed] [Google Scholar]
- 16. Zanette I, Enders B, Dierolf M, Thibault P, Gradl R, Diaz A, et al. Ptychographic x-ray nanotomography quantifies mineral distributions in human dentine. Sci Rep. 2015;5:9210 10.1038/srep09210 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Dowker SE, Elliott JC, Davis GR, Wilson RM, Cloetens P. Synchrotron x-ray microtomographic investigation of mineral concentrations at micrometre scale in sound and carious enamel. Caries Res. 2004;38:514–522. 10.1159/000080580 [DOI] [PubMed] [Google Scholar]
- 18. Langer M, Pacureanu A, Suhonen H, Cloetens P, Peyrin F. X-ray phase nanotomography resolves the 3D human bone ultrastructure. Plos ONE. 2012;7:e35691 10.1371/journal.pone.0035691 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19. Zanette I, Weitkamp T, Lang S, Mohr J, David C, Baruchel J. Quantitative phase and absorption tomography with an x-ray grating interferometer and synchrotron radiation. Physica Status Solidi A. 2011;208:2526–2532. 10.1002/pssa.201184276 [DOI] [Google Scholar]
- 20. Velroyen A, Bech M, Zanette I, Schwarz J, Rack A, Tympner C, et al. X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage. Plos ONE. 2014;9:e109562 10.1371/journal.pone.0109562 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Tapfer A, Braren R, Bech M, Willner M, Zanette I, Weitkamp T, et al. X-Ray Phase-Contrast CT of a Pancreatic Ductal Adenocarcinoma Mouse Model. Plos ONE. 2013;8:e58439 10.1371/journal.pone.0058439 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Jensen TH, Bech M, Binderup T, Böttiger A, David C, Weitkamp T, et al. Imaging of Metastatic Lymph Nodes by X-ray Phase-Contrast Micro-Tomography. Plos ONE. 2013;8:e54047 10.1371/journal.pone.0054047 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. Herzen J, Donath T, Pfeiffer F, Bunk O, Padeste C, Beckmann F, et al. Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source. Optics Express. 2009;17(12):10010–10018. 10.1364/OE.17.010010 [DOI] [PubMed] [Google Scholar]
- 24. Willner M, Bech M, Herzen J, Zanette I, Hahn D, Kenntner J, et al. Quantitative X-ray phase-contrast computed tomography at 82 keV. Optics Express. 2011;21(4):4155–4166. 10.1364/OE.21.004155 [DOI] [PubMed] [Google Scholar]
- 25. Sarapata A, Chabior M, Cozzini C, Sperl J, Bequé D, Langner O, et al. Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging. Review of Scientific Instruments. 2014;85(10):103708 10.1063/1.4898052 [DOI] [PubMed] [Google Scholar]
- 26. Sarapata A, Willner M, Walter M, Duttenhofer T, Kaiser K, et al. Quantitative imaging using high-energy X-ray phase-contrast CT with a 70 kVp polychromatic X-ray spectrum. Optics Express. 2015;23(1):523–535. 10.1364/OE.23.000523 [DOI] [PubMed] [Google Scholar]
- 27. Momose A, Kawamoto S, Koyama I, Hamaishi Y, Takai K, Suzuki Y. Demonstration of X-ray Talbot Interferometry. J Appl Phys. 2003;42:866–868. [Google Scholar]
- 28. Weitkamp T, Diaz A, David C, Pfeiffer F, Stampanoni M, Cloetens P, et al. X-ray phase imaging with a grating interferometer. Optics Express. 2005;12(16):629–6304. [DOI] [PubMed] [Google Scholar]
- 29. Cloetens P, Ludwig W, Baruchel J, Dyck DV, Landuyt JV. An X-ray Interferometer. Appl Phys Lett. 1999;75(19):2912–2914. [Google Scholar]
- 30. Pfeiffer F, Bech M, Bunk O, Kraft P, Eikenberry EF, Brönnimann C, et al. Hard-X-ray dark-field imaging using a grating interferometer. Nature Physics. 2008;7:134–137. 10.1038/nmat2096 [DOI] [PubMed] [Google Scholar]
- 31. Pfeiffer F, Kottler C, Bunk O, David C. Hard X-Ray Phase Tomography with Low-Brilliance Sources. Phys Rev Lett. 2007;98:108105 10.1103/PhysRevLett.98.108105 [DOI] [PubMed] [Google Scholar]
- 32. Bech M, Bunk O, Donath T, Feidenhans’l R, David C, Pfeiffer F. Quantitative x-ray dark-field computed tomography. Phys Med Biol. 2010;55:5529–5539. 10.1088/0031-9155/55/18/017 [DOI] [PubMed] [Google Scholar]
- 33. Qi Z, Zambelli J, Bevins N, Chen GH. Quantitative imaging of electron density and effective atomic number using phase contrast CT. Phys Med Biol. 2010;55(9):2669–2677. 10.1088/0031-9155/55/9/016 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Shrimpton PC. Electron density values of various human tissues: in vitro Compton scatter measurements and calculated ranges. Phys Med Biol. 1981;26(5):907–911. 10.1088/0031-9155/26/5/010 [DOI] [PubMed] [Google Scholar]
- 35. Willner M, Bech M, Herzen J, Zanette I, Hahn D, Kenntner J, et al. Quantitative grating-based X-ray phase-contrast imaging at 82 keV. Optics Express. 2013;21:4155–4166. 10.1364/OE.21.004155 [DOI] [PubMed] [Google Scholar]
- 36. Weitkamp T, Tafforeau P, Boller E, Cloetens P, Valade JP, Bernard P, et al. Status and evolution of the ESRF beamline ID19. AIP Conf Proc. 2010;1221(1):33–38. 10.1063/1.3399253 [DOI] [Google Scholar]
- 37. Reznikova E, Mohr J, Börner M, Nazmov V, Jakobs PJ. Soft X-ray lithography of high aspect ratio phase contrast imaging SU8 submicron structures. Microsyst Technol. 2008;14:1683–1688. [Google Scholar]
- 38. Manly RS, Hodge HC, Ange LE. Density and refractive index studies of dental hard tissues. J Dent Res. 1939;p. 203–211. 10.1177/00220345390180030301 [DOI] [Google Scholar]
- 39. Kinney JH, Nalla RK, Pople JA, Breunig TM, Ritchie RO. Age-related transparent root dentin: mineral concentration, crystallite size, and mechanical properties. Biomaterials. 2005;26:3363–3376. 10.1016/j.biomaterials.2004.09.004 [DOI] [PubMed] [Google Scholar]
- 40. Schwass DR, Swain MV, Purton DG, Leichter JW. A System of Calibrating Microtomography for Use in Caries Research. Caries Res. 2009;43:314–321. 10.1159/000226230 [DOI] [PubMed] [Google Scholar]
- 41. Dowker SEP, Elliott JC, Davis GR, Wilson RM, Cloetens P. Three-dimensional study of human dental fissure enamel by synchrotron X-ray microtomography. J Oral Sci. 2006;114:335–359. 10.1111/j.1600-0722.2006.00315.x [DOI] [PubMed] [Google Scholar]
- 42. Weidmann SM, Weatherell JA, Hamm SM. Variations of enamel density in sections of human teeth. J Oral Biol. 1967;12:85–97. 10.1016/0003-9969(67)90145-8 [DOI] [PubMed] [Google Scholar]
- 43. Angmar B, Carlstr D, Glas JE. Studies on the Ultrastructure of Dental Enamel. J Ultrastruct Res. 1963;8:12–23. 10.1016/S0022-5320(63)80017-9 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The raw data underlying the results of this report is stored in the public repository figshare (https://figshare.com/articles/part01_zip/4224228).