Skip to main content
Experimental and Therapeutic Medicine logoLink to Experimental and Therapeutic Medicine
. 2016 Oct 18;12(6):3675–3679. doi: 10.3892/etm.2016.3813

Correlation between high perfusion syndrome and stent restenosis after stent implantation

Yingyi Li 1, Lingtao Tang 1, Dong Qi 1, Chunlei Wang 2, Suxia Zhang 1, Pengfei Hu 1, Yun Wang 1, Bogang Zhang 1, Kunxi Zhang 1,
PMCID: PMC5228199  PMID: 28101162

Abstract

The present study was conducted to determine the correlation between high perfusion syndrome and stent restenosis after cerebral vascular stent implantation. A total of 146 patients diagnosed with cerebral vascular stenosis and stent implantation were selected. A total of 55 cases (37.67%) of cerebral hyperperfusion syndrome patients were diagnosed by xenon-enhanced computer tomography (Xe-CT) examination and clinical symptoms within 3 days after surgery and were chosen as the observation group. A total of 91 cases were selected as the control group. After treatment, blood flow of the anterior cerebral artery, middle cerebral artery, posterior cerebral artery, anterior border zone, posterior border zone and the inner border zone of the two groups increased, with values in the observation group increasing more significantly, and the differences were statistically significant (P<0.05). The rate of restenosis and target lesion diameter one month and one year after operation in the observation group were significantly higher than those in the control group (P<0.05). Multivariate logistic regression analysis showed that the mean systolic blood pressure (mSBP), mean diastolic blood pressure (mDBP), stenosis rate of cerebral vascular diameter and high perfusion syndrome were independent risk factors for restenosis (P<0.05). The application of Xe-CT examination is important for early diagnosis of hyperperfusion syndrome. Hyperperfusion syndrome and the occurrence of stent restenosis are closely related. mSBP, mDBP, cerebral blood vessel diameter stenosis rate and high perfusion comprehensive syndrome are the independent risk factors of restenosis.

Keywords: cerebral vascular stent implantation, high perfusion syndrome, stent restenosis

Introduction

Cerebrovascular disease is a common disease with a high incidence rate, a high disability rate, high recurrence rate and high mortality (1). Approximately 70% of the patients lose working and self-care ability, and it is a serious threat to the health and quality of life of the elderly population. Cerebral vascular stent implantation can effectively relieve cerebral artery stenosis, but high perfusion syndrome after implantation is a serious complication of carotid artery stenting (2). This occurs mainly due to the rapid increase in perfusion pressure of the microvascular bed which leads to blood-brain barrier damage accompanied by related clinical symptoms, such as intracranial hemorrhage, brain edema, the side of moderate to severe headache, hemiplegia, aphasia and epilepsy (3).

Stent restenosis is also a serious complication (4), which can be diagnosed by computed tomography angiography (CTA). There may be a correlation between cerebral hyperperfusion syndrome (CHS) and ISR, but there is less research on this issue.

The aim of the present study was to analyze the relationship between the two groups, and to analyze the influencing factors in order to provide a reference for clinical early intervention.

Materials and methods

General information

A total of 146 patients diagnosed with cerebral vascular stenosis and stent implantation were selected in the Third Hospital of Xingtai City from January 2010 to January 2016. All the patients had single target site lesions that led to acute cerebral infarction, with vascular stenosis rate of >90%, and stent implantation indications, expected to be effective after treatment. Exclusion criteria included patients with cerebral hemorrhage, congenital vascular brain development abnormalities, and the tiny blood vessels without appropriate scaffold types or unable to complete lesion coverage, intraoperative acute stent thrombosis, blood vessel perforation, hemorrhage, brain tumor, recent surgery, blood coagulation dysfunction, serious illness, and an expected survival period of <12 months. The study was approved by the Ethics Committee of the Third Hospital of Xingtai City and written informed consent of patients or their families was obtained. Patients were recruited within 3 days after operation by xenon-enhanced CT (Xe-CT) examination and clinical symptoms, which confirmed high perfusion comprehensive syndrome in 55 patients (37.67%), which were designated the observation group. The remaining 91 cases were designated as the control group, and baseline data of the two groups was comparable (Table I).

Table I.

Comparison of baseline data between two groups.

Item Control group, n=91 Observation group, n=55 t/χ2 P-value
Male/female 52/39 33/22 0.115 0.734
Age, year   58.8±7.6   59.6±7.5 0.230 0.685
Time of onset, h   8.2±2.5   8.3±2.4 0.167 0.722
Smoke, cases (%) 13 (14.29) 8 (14.55) 0.002 0.965
Diabetes, cases (%) 10 (10.99) 6 (10.91) 0.000 0.988
Cholesterol total, mmol/l   5.7±0.8   5.8±0.7 0.245 0.623
Low density lipoprotein, mmol/l   4.5±1.0   4.7±1.2 0.324 0.522
BMI, kg/m2   22.4±2.2   22.6±2.5 0.335 0.503
mSBP, mmHg 165.7±4.3 167.2±4.4 0.267 0.642
mDBP, mmHg 102.4±5.2 103.6±5.6 0.423 0.527
Cerebral vascular stenosis rate, %   96.8±3.3   97.2±3.5 0.236 0.647
Stent length, mm   12.3±3.2   13.4±3.3 0.326 0.632

BMI, body mass index; mSBP, mean systolic blood pressure; mDBP, mean diastolic blood pressure.

Stent implantation

The study was completed by the same surgical and nursing team, based on standard medical procedures. In order to improve preoperative preparation, we used subcutaneous local anesthesia and used Seldinger's puncture technique. We placed the wire into the arterial sheath, guided the wire through to stenosis, along the catheter and put balloon dilatation into the target lesion and slowly increased the pressure in the balloon until it reached a maximum pressure lasting 20 sec. After the full expansion, we implanted drug eluting stents and performed stent coverage beyond the narrow section at 5 mm, with routine expansion. After stent placement, the artery sheath was retained for 6 h and removed. We applied perioperative routine anticoagulation and antiplatelet therapy, and reduced intracranial pressure, controlled blood pressure, blood glucose levels, blood lipids and stabilize internal environment.

Xe-CT check

The PLUS4CT scanner (Siemens AG, Munich, Germany) combined American xenon-CT were used. Patient was held supine with head fixed by fiber glass head fixation. A vacuum bag as a head brake. We first took a CT routine scan of the head, and then xenon mixed gas inhalation with the concentration of 30% was carried out through the mask. The patients remained awake in order to control the frequency and depth of breathing and to ensure the stability of the respiratory CO2 concentration, in the process of xenon inhalation. Patients were continuously scanned, 6 times, through the basement, we took a Xe-CT scan slice (thickness 10 mm), and took the central, lenticular nucleus, caudate nucleus and thalamus level of the lateral ventricle anterior horn of patients as the first layer. We sequentially scanned, getting the images of fourth layer. After the end of the scan, we removed the mask to assess the patients. The observation sites include: i) Anterior cerebral artery (ACA); ii) middle cerebral artery (MCA); iii) Posterior cerebral artery (PCA); iv) anterior border zone (ABZ): Between the ACA and the MCA; v) Posterior border zone (PBZ), located in the MCA and the middle artery blood supply scope, namely the temporal, the top, the occipital border area; and vi) inner border zone (IBZ), located between the cortical branch of MCA and the artery of the bean, the recurrent artery and the anterior choroidal artery, next to the basal ganglia and the lateral ventricles. The cerebral blood flow (CBF) of the observation site abnormally increased and the typical lesions were beaded or linearly changed.

CTA check

We followed up 1 month and 1 year after surgery. We performed a routine CT plain scan, and then the high pressure syringe was injected with 35 ml iodine contrast agent and 0.9% sodium chloride solution at the speed of 7 ml/sec and delayed 5 sec for enhanced scan. At the end of the scan, we used multi planar reconstruction, surface reconstruction, maximum density projection, volume display and other techniques for restructuring. We measured the diameter of the narrow blood vessels and normal blood vessels in the stent. Stenosis rate of vascular lumen in stent ≥50% is the standard for restenosis.

Statistical analysis

SPSS 19.0 software (SPSS, Inc., Chicago, IL, USA) was used for data analysis. Quantitative data were expressed as mean ± standard deviation. The group comparison was tested by independent sample t-test, and comparison within group was tested by paired t-test. Countable data were expressed by the rate and χ2 test was used. A logistic regression model was used to influence factor analysis of stent restenosis. P<0.05 was considered to indicate a statistically significant difference.

Results

Xe-CT examination result analysis

After treatment, the blood flow of ACA, MCA, PCA, ABZ, PBZ, and IBZ in both groups increased; the observation group increased more significantly, and the differences were statistically significant (P<0.05; Table II).

Table II.

Xe-CT examination results analysis (ml/(100 g·min).

Group Control group Observation group t P-value
ACA
  Before operation 35.6±4.3 34.6±4.4 0.069 0.923
  3 days after operation 40.5±5.2 48.9±5.3 4.632 0.037
MCA
  Before operation 32.4±3.6 32.3±3.5 0.072 0.914
  3 days after operation 36.6±3.7 42.3±3.9 4.527 0.039
PCA
  Before operation 27.6±3.2 26.5±3.3 0.125 0.867
  3 days after operation 32.3±3.5 37.6±3.7 5.201 0.033
ABZ
  Before operation 23.3±3.0 22.4±3.2 0.135 0.822
  3 days after operation 26.7±3.2 32.3±3.3 5.326 0.031
PBZ
  Before operation 21.4±2.8 20.3±2.6 0.164 0.735
  3 days after operation 25.4±2.7 30.5±2.5 5.526 0.026
IBZ
  Before operation 16.7±2.3 15.8±2.4 0.245 0.635
  3 days after operation 18.3±2.6 25.4±2.7 5.127 0.035

Xe-CT, xenon-enhanced computer tomography; ACA, anterior cerebral artery; MCA, middle cerebral artery; PCA, posterior cerebral artery; ABZ, anterior border zone; PBZ, posterior border zone; IBZ, inner border zone.

Comparison of the incidence of stent restenosis

The rate of restenosis and target lesion diameter 1 month and 1 year after operation in the observation group were significantly higher than those in the control group, and the differences were statistically significant (P<0.05; Table III).

Table III.

Comparison of the incidence of stent restenosis.

Group No. of cases Restenosis rate 1 month after operation, cases (%) Target lesion diameter loss ratio, % Restenosis rate 1 year after operation, cases (%) Target lesion diameter loss rate, %
Control 91 18 (19.78) 35.4±10.2 23 (25.27) 42.3±15.4
Observation 55 20 (36.36) 76.8±15.6 28 (50.91) 86.5±18.2
t/χ2 4.897 9.632 9.911 13.232
P-value 0.027 0.000 0.002   0.000

Comparison of the incidence of stent restenosis

We used the general information of patients including gender, age, time of disease onset, smoking, diabetes, total cholesterol, low density lipoprotein, BMI, mean systolic blood pressure (mSBP), mean diastolic blood pressure (mDBP), cerebral vascular diameter stenosis, stent length, high perfusion syndrome, Xe-CT parameters (blood flow of ACA, MCA, PCA, ABZ, PBZ and IBZ) as the independent variables. As a dependent variable, restenosis was included in the logistic regression model, and the method of stepwise regression was used for screening (α<0.10 as entry criteria, <0.05 as exclusion criteria). We found that mSBP, mDBP, cerebral vascular stenosis rate and high perfusion syndrome were the independent risk factors for restenosis (Table IV).

Table IV.

Multivariate logistic regression analysis.

Factor B Wald P-value OR 95% CI
mSBP 0.063 4.527 0.037 1.234 0.635–2.532
mDBP 0.027 4.231 0.039 1.120 0.764–2.514
Cerebral vascular stenosis rate 0.125 5.203 0.025 2.635 2.103–3.527
Hyperperfusion syndrome 0.136 5.639 0.018 3.205 2.857–3.638

B, regression coefficient; OR, odds ratio; CI, confidence interval; mSBP, mean systolic blood pressure; mDBP, mean diastolic blood pressure.

Discussion

High perfusion syndrome after cerebral vascular stent implantation

CHS is a serious complication of cerebral vascular stent implantation. Cerebral vascular stenosis leads to functional decline of automatic regulation, insufficient blood volume of brain tissue, and adaptability to low perfusion pressure. After stent implantation, vascular stenosis rapidly relieves and the intracranial blood flow increases sharply, leading to a sharp increase in capillary bed perfusion pressure. These events cause the cerebrovascular system not to contract timely and effectively, which is an obstacle of the blood brain barrier mechanism and leads to brain edema and intracranial hemorrhage (5,6). Occasionally the clinical symptoms are not obvious, and can easily be ignored (7).

The formation mechanism of high perfusion

High perfusion formation mechanism includes: i) Cell trauma (8): The narrow cerebral blood vessel reperfusion injury activates the ring oxidase, lipid oxidase and brain cell microsomes, which produce catalytic action to prevent acid metabolism with free radical generation. We strengthened lipid peroxidation, and changed the lipid microenvironment. This cascade of reactions continues to damage the lipid structure, resulting in cell structure and functional damage. ii) Loss of brain cell function (9): Brain cells and some of the activating enzymes have cross-linking reaction, with the formation of the two polymers, resulting in the loss of brain cells. iii) Free radical toxicity (10): Free radicals can produce toxic effects on brain cells, which can be expressed as nucleic acid base changes, chromosome aberration or DNA fault. iv) Complement activation (11): The complement terminal complex affects the brain cell function through the membrane mechanism, which triggers the release of the macrophages, and produces a variety of inflammatory factors, which can cause damage to the neurons.

Diagnosis of high perfusion syndrome

Diagnosis of high perfusion syndrome should be combined with clinical manifestations, MRA, TCD and other examinations. Among them, MRA can display intracranial and extracranial vessels, which are suitable for preoperative risk factor assessment. The abnormal manifestations include white matter edema (mainly related to occipital region), focal cerebral infarction and cerebral hemorrhage (12). TCD through cranial window can measure cerebral vascular blood flow velocity, reflect the preoperative low perfusion, brain vascular reaction, post-operative hyperperfusion and postoperative emboli formation. In clinical use, it has good diagnostic sensitivity and accuracy (13). However, due to the variation in operator experience, personal variability is very different. The human cerebral artery regulates the CBF through its own regulation mechanism, which is normally maintained at 50 ml/(100 g·min). Xe-CT can quantitatively display cerebral perfusion with convenient inspection, on the basis of routine CT examinations, fast evaluation of CBF and vascular reserve capacity, especially after stent implantation. Quantitative detection of cerebral arterial blood flow can be an effective method for diagnosis of high perfusion comprehensive syndrome of patients and improvement after operation to provide the basis for the judgment of prognosis of patients and reduce ISR (14,15).

Effects of high perfusion on restenosis

After hyperperfusion syndrome, cerebral artery hemodynamics change, inducing basic fibroblast growth factor (bFGF) and platelet-derived growth factor (PDGF) expression, bFGF and PDGF may promote the division and proliferation of vascular endothelial cells, and induce migration proliferation of smooth muscle cells, ultimately lead to vascular intimal hyperplasia (16,17). Puffiness has creeping growth along the stent mesh, the stent neointimal coverage area increases, so that stent restenosis occurs.

The results of the study showed that the incidence of high perfusion syndrome after stent implantation was ~37.67% and that the blood flow rate of MCA, PCA, ABZ, PBZ, IBZ and ACA in patients with high perfusion syndrome significantly increased at 1 month and 1 year after operation. The rate of restenosis and target lesion diameter loss rate were significantly higher than in the observation groups compared to those in the control group. The high average systolic blood pressure and diastolic blood pressure, high brain vascular diameter stenosis rate and high perfusion comprehensive syndrome were the independent risk factors of restenosis. In conclusion, the application of Xe-CT examination has important value for early diagnosis of hyperperfusion syndrome, hyperperfusion syndrome and the occurrence of stent restenosis are closely related. Mean systolic pressure, mDBP, cerebral blood vessel diameter stenosis rate and high perfusion comprehensive syndrome are the independent risk factors of restenosis.

References

  • 1.Gao JH, Gao XP, Pan SY. Perioperative intensive statin therapy improves outcomes in patients with ischemic stroke undergoing middle cerebral artery stent implantation. Nan Fang Yi Ke Da Xue Xue Bao. 2016;36:356–360. (In Chinese) [PubMed] [Google Scholar]
  • 2.Zhang Y, Kumar A, Tezel JB, Zhou Y. Imaging evidence for cerebral hyperperfusion syndrome after intravenous tissue plasminogen activator for acute ischemic stroke. Case Rep Neurol Med. 2016;2016:8725494. doi: 10.1155/2016/8725494. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Peker A, Sorgun MH, Isikay CT, Arsava EM, Topcuoglu MA, Arat A. Perioperative and follow-up results in carotid artery stenting with contralateral carotid occlusion. Jpn J Radiol. 2016;34:523–528. doi: 10.1007/s11604-016-0554-2. [DOI] [PubMed] [Google Scholar]
  • 4.Zhao Y, Jin M, Liu Q, Liu D, Chen J, Du B. A long-term follow-up results of Enterprise stent in treatment of severe symptomatic basilar artery atherosclerotic stenosis. Zhonghua Nei Ke Za Zhi. 2016;55:372–376. doi: 10.3760/cma.j.issn.0578-1426.2016.05.008. (In Chinese) [DOI] [PubMed] [Google Scholar]
  • 5.Guirgis M, Sieunarine K. Cerebral hyperperfusion syndrome: A rare postoperative complication of carotid endarterectomy. Am J Emerg Med. 2016 Mar 5; doi: 10.1016/j.ajem.2016.03.010. (Epub ahead of print) [DOI] [PubMed] [Google Scholar]
  • 6.Pinho J, Amorim JM, Alves JN, Araújo JM, Ferreira C. Cerebral hyperperfusion syndrome after internal carotid artery dissection with persistent occlusion. Neurol Sci. 2016;37:1175–1177. doi: 10.1007/s10072-016-2517-x. [DOI] [PubMed] [Google Scholar]
  • 7.Uchida K, Yoshimura S, Shirakawa M, Shindo S, Egashira Y, Iwama T, Yamada K. Experience of Staged Angioplasty to Avoid Hyperperfusion Syndrome for Carotid Artery Stenosis. Neurol Med Chir (Tokyo) 2015;55:824–829. doi: 10.2176/nmc.oa.2015-0102. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Chadha DS, Singh N, Tewari AK, Kumar RS, Yadav KK, Naveen AJ, Bhartiya M, Gupta VK, Wagh A, Ghosh AK. Hyperperfusion Syndrome after Carotid Artery Stenting. Med J Armed Forces India. 2015;71:S156–S159. doi: 10.1016/j.mjafi.2013.10.008. (Suppl 1) [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Aralasmak A, Atay M, Toprak H, Ozdemir T, Asil T, Goktekin O, Mehdi E, Ozdemir H, Alkan A. Hyperperfusion in carotid stenting patients. J Comput Assist Tomogr. 2015;39:313–316. doi: 10.1097/RCT.0000000000000211. [DOI] [PubMed] [Google Scholar]
  • 10.Oh SI, Lee SJ, Lee YJ, Kim HJ. Delayed cerebral hyperperfusion syndrome three weeks after carotid artery stenting presenting as status epilepticus. J Korean Neurosurg Soc. 2014;56:441–443. doi: 10.3340/jkns.2014.56.5.441. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Xu S, Wu P, Shi H, Ji Z, Dai J. Hyperperfusion Syndrome After Stenting for Intracranial Artery Stenosis. Cell Biochem Biophys. 2015;71:1537–1542. doi: 10.1007/s12013-014-0377-7. [DOI] [PubMed] [Google Scholar]
  • 12.Sato K, Yamada M, Kuroda H, Yamamoto D, Asano Y, Inoue Y, Fujii K, Kumabe T. Time-of-flight MR angiography for detection of cerebral hyperperfusion syndrome after superficial temporal artery-middle cerebral artery anastomosis in moyamoya disease. Am J Neuroradiol. 2016;37:1244–1248. doi: 10.3174/ajnr.A4715. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Orion D, Yavne Y, Peretz S, Givaty G. Diagnosing hyperperfusion syndrome: CT perfusion or transcranial doppler? Isr Med Assoc J. 2015;17:656–658. [PubMed] [Google Scholar]
  • 14.Yoshie T, Ueda T, Takada T, Nogoshi S, Fukano T, Hasegawa Y. Prediction of cerebral hyperperfusion syndrome after carotid artery stenting by CT perfusion imaging with acetazolamide challenge. Neuroradiology. 2016;58:253–259. doi: 10.1007/s00234-015-1623-4. [DOI] [PubMed] [Google Scholar]
  • 15.Schoknecht K, Gabi S, Ifergane G, Friedman A, Shelef I. Detection of cerebral hyperperfusion syndrome after carotid endarterectomy with CT perfusion. J Neuroimaging. 2014;24:295–297. doi: 10.1111/j.1552-6569.2012.00773.x. [DOI] [PubMed] [Google Scholar]
  • 16.Osadnik T, Strzelczyk JK, Reguła R, Bujak K, Fronczek M, Gonera M, Gawlita M, Wasilewski J, Lekston A, Kurek A, et al. The relationships between polymorphisms in genes encoding the growth factors TGF-β1, PDGFB, EGF, bFGF and VEGF-A and the restenosis process in patients with stable coronary artery disease treated with bare metal stent. PLoS One. 2016;11:e0150500. doi: 10.1371/journal.pone.0150500. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Guildford AL, Stewart HJ, Morris C, Santin M. Substrate- induced phenotypic switches of human smooth muscle cells: An in vitro study of in-stent restenosis activation pathways. J R Soc Interface. 2011;8:641–649. doi: 10.1098/rsif.2010.0532. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Experimental and Therapeutic Medicine are provided here courtesy of Spandidos Publications

RESOURCES