Abstract
As breast cancer tissues are stiffer than normal tissues, shear wave elastography (SWE) can locally quantify tissue stiffness and provide histological information. Moreover, tissue stiffness can be observed on three-dimensional (3D) colour-coded elasticity maps. Our objective was to evaluate the diagnostic performances of quantitative features in differentiating breast masses by two-dimensional (2D) and 3D SWE. Two hundred ten consecutive women with 210 breast masses were examined with B-mode ultrasound (US) and SWE. Quantitative features of 3D and 2D SWE were assessed, including elastic modulus standard deviation (ESDE) measured on SWE mode images and ESDU measured on B-mode images, as well as maximum elasticity (Emax). Adding quantitative features to B-mode US improved the diagnostic performance (p < 0.05) and reduced false-positive biopsies (p < 0.0001). The area under the receiver operating characteristic curve (AUC) of 3D SWE was similar to that of 2D SWE for ESDE (p = 0.026) and ESDU (p = 0.159) but inferior to that of 2D SWE for Emax (p = 0.002). Compared with ESDU, ESDE showed a higher AUC on 2D (p = 0.0038) and 3D SWE (p = 0.0057). Our study indicates that quantitative features of 3D and 2D SWE can significantly improve the diagnostic performance of B-mode US, especially 3D SWE ESDE, which shows considerable clinical value.
Breast cancer is one of the chief causes of death among women worldwide1. Ultrasound (US), as an irreplaceable tool in breast imaging and an adjunct to mammography2, is also used as a first-line examination to both detect and characterize breast masses. The Breast Imaging Reporting and Data System (BI-RADS) with US3 provides a standardized terminology for describing and classifying breast masses, and satisfactory diagnostic performance has been recently reported4. However, conventional US has an important limitation, i.e., low specificity, as reported in previous research5,6. Recent studies have demonstrated that US elastography developed in the past decade can improve the diagnostic performance of breast US, including its specificity7,8.
Malignant breast masses are generally stiff, and benign masses are generally soft9. US elastography is a new diagnostic imaging method for detecting the degree of tissue stiffness. Recent studies have demonstrated that strain elastography, an important adjunct to US10,11, shows notable diagnostic performance in differentiating benign and malignant breast lesions, with a sensitivity of 78–98.6% and a specificity of 51.7–98.5%12,13,14,15,16. However, as the elasticity map obtained is highly dependent on the extent of tissue compression and on the tissue’s compressibility limits under stress, the quality and reliability of strain elastography are affected considerably by interobserver variability during data acquisition and interpretation17. In addition, the acquired information is a qualitative rather than a quantitative measurement of local strain, rendering the efficacy of the modality a matter of debate.
Shear wave elastography (SWE), a quantitative imaging technique, has been developed to address the above problems. Reportedly, SWE decreases the operator dependence and shows high reproducibility18,19,20. This technique allows the measurement of the propagation speed of shear waves within tissues in metres per second (m/s) to locally quantify tissue stiffness (Young’s modulus) in kilopascals (kPa). Several studies have reported the diagnostic application of SWE to differentiating breast mass types7,21,22,23. These studies have shown that the addition of SWE parameters can improve the diagnostic accuracy of breast US7,8,24,25. Moreover, according to Evans26, SWE elasticity values in breast cancer tissues show a significant association with prognostic factors, including tumour invasion, type and histological grade.
However, most studies of SWE have focused on two-dimensional (2D) images; thus, the main SWE images for breast masses have been obtained on a single imaging plane. As a result, the information on the elasticity of breast lesions is far from being exhaustively evaluated. To address this issue, three-dimensional (3D) SWE has been introduced for breast US diagnosis. This technology can reconstruct volumetric images from data obtained from a single sweep of the US beam across the entire area of interest. In 3D SWE, comprehensive elastographic information about all aspects of masses can be obtained. In addition, the heterogeneity of the whole mass can be viewed in three dimensions. The stiffest position within a mass can be effectively observed, and various stiffness values can be quantitatively measured. 3D SWE has been shown to provide acceptable interobserver agreement27. Lee et al.28 reported that the quantitative factors of both 2D and 3D SWE, such as the maximum stiffness (Emax), stiffness ratio (Erat) and mean stiffness (Emean), have significantly improved the diagnostic performance of breast US. However, the evaluation of these quantitative factors is susceptible to disturbances during 3D SWE image acquisition that can cause artefacts28. To the best of our knowledge, few studies have reported on how to assess the standard deviation (SD) values in 3D SWE. Additionally, the measurement methods used for assessing SD values have been inconsistent in different studies29,30.
The objective of our study was to analyse the diagnostic value of SD measured by different methods and to evaluate the diagnostic performance of elasticity features (Emax and SD) quantified by 2D and 3D SWE to distinguish benign from malignant breast masses.
Materials and Methods
Patients and masses
This retrospective study was conducted with approval from the Institutional Review Board of the First Affiliated Hospital of Harbin Medical University, and informed patient consent was waived. The methods in our study were applied in accordance with approved guidelines. From March 2014 to May 2015, 248 consecutive women were examined with B-mode US and both 2D and 3D SWE before undergoing US-guided core needle biopsy (CNB) or surgical breast mass excision. The exclusion criteria were as follows: women with breast implants; women who previously underwent breast surgery and had a family history of breast cancer; women who were pregnant or breast feeding; women whose masses were categorized as BI-RADS 0 or 63; and women whose masses were larger than the maximum width of the SWE colour overlay, which was 3 cm. One lesion per patient was included. The inclusion criteria for multiple breast masses were as follows: if multiple masses were present, that with the most suspicious morphological features was evaluated by B-mode US; if all the masses showed malignant morphological features, a randomly selected mass was evaluated; if all the masses showed benign morphological features, a randomly selected mass was evaluated. A total of 210 solid breast masses in 210 women aged from 18 to 80 years (mean, 43.12 ± 13.34 years) were included in this study. One hundred fifty-one (71.9%) of these women were symptomatic, including 112 patients with a palpable mass, 13 with nipple discharge and 41 with breast pain. One hundred sixty-eight breast masses were visible on mammograms.
The histopathological evaluation of the breast lesions was performed by a pathologist with 20 years of experience in breast pathology. US-guided CNB was initially performed for breast masses assigned BI-RADS categories of 5 and 4, and masses assigned BI-RADS categories of 3 and 2 were evaluated at the request of the patient or referring physician. After CNB, some benign breast masses were excised depending on the preferences of the physician and patient. For masses with benign biopsy histological findings, six to eight months of US follow-up was recommended to confirm the mass stability. The histopathology of the 210 breast masses was confirmed via US-guided CNB (n = 112) and surgery (n = 98).
US examination
B-mode US and SWE were performed using an Aixplorer US system (SuperSonic Imagine, Aix-en-Provence, France) by one of three experienced radiologists. 2D US and SWE images were acquired using a 4- to 15-MHz linear-array transducer. 3D SWE images were acquired using a 5- to 16-MHz dedicated mechanical volumetric transducer. The greyscale US features of the breast masses were assessed on 2D US images acquired on 2 orthogonal planes, according to the BI-RADS US. The longest diameter of each mass was measured on the B-mode images.
After B-mode US, 2D and 3D SWE acquisitions were performed for the breast masses that were scheduled to be biopsied or excised. During image acquisition, the probe was maintained perpendicular to the skin and kept still for a few seconds to stabilize the SWE images31. To reduce artefactual stiffness, after the probe was applied with the slightest pressure and a generous layer of US gel, the patients were instructed to hold their breath. A square region of interest (ROI) set for SWE acquisition was adjusted to include the whole mass and surrounding normal tissue observed by B-mode, excluding the skin and chest wall. In the ROI, stiffness was displayed as a semi-transparent colour-overlaid map using the default stiffness range from dark blue to red (0–180 kPa). For 2D SWE, masses were observed by different cross-sectional views. SWE images were chosen and saved in top-bottom display format for retrospective analysis. The total examination was accomplished in less than 5 minutes, including the 2D B-mode US examination. For 3D SWE, the SuperSonic 3D breast probe acquired 2D images and reconstructed a 3D image from the 2D data. Volumetric SWE data were reconstructed and displayed in multi-slice and multi-planar views by featuring the transverse, sagittal, and coronal planes. With a slow-tilt movement of the sectorial mechanical transducer and a sweep angle of 10–30°, volumetric imaging was automatically performed, and the data were saved as image files for later review. The 3D SWE examination was accomplished in less than 5 minutes.
Image evaluation
All the images were reviewed by two radiologists together who were blinded to the clinical, mammographic and pathological findings. Disagreements were resolved by consensus. The Emax and SD of each mass were measured for the quantitative analysis. Three separate SWE acquisitions were performed for each mass, and the averages of the elasticity values were used in this analysis. In our study, SD was measured using two methods in both 2D and 3D SWE. The size of the ROI for the two measurement methods was adjusted according to the breast mass size. In one method, the built-in ROI (Q-BoxTM; SuperSonic Imagine) adjusted to the mass contours on SWE-mode images was set to include the mass and immediate adjacent stiff tissue or halo. This calculated SD was recorded as ESDE. In the other method, a Q-Box adjusted to the mass contours on B-mode images was placed within the mass to encompass the maximum mass area. This calculated SD was recorded as ESDU (Fig. 1). For 2D SWE, Emax was measured using the first method. For 3D SWE, quantitative variables were measured on all the three orthogonal planes as follows: on the multi-slice view, a 2-mm2 Q-Box was placed on the stiffest area of the mass or its adjacent periphery, and the Emax value was recorded (Fig. 1). Two SD measurements were performed on the same SWE image, which included the largest equatorial plane of the mass (Fig. 1).
There were five data sets, consisting of B-mode US, 2D SWE, 3D SWE, and combined sets of B-mode US and SWE data. According to the American College of Radiology (ACR)-BI-RADS, the second version for US, the final assessment category of each mass was recorded by the reviewers to indicate the probability of malignancy among categories 2, 3, 4, 4a, 4b, 4c, and 532. According to the ACR guidelines, masses categorized as BI-RADS 4a or higher were recommended to undergo a biopsy, and masses categorized as BI-RADS 3 were recommended for follow-up only. The hypothetical effect of the combination of SWE with conventional US was evaluated to inform the management decision over whether to perform a biopsy. Another assessment was performed with combined sets of greyscale and SWE data, taking the B-mode US BI-RADS information as the starting point. Reviewers were asked to downgrade or upgrade masses and change their BI-RADS classification using the following rules: if SWE variables did not suggest malignancy (i.e., were below the cut off values), BI-RADS category 4a masses would be moved to BI-RADS category 3; if SWE variables did suggest malignancy (i.e., were equal to or larger than the cut off values), BI-RADS category 3 masses would be moved to BI-RADS category 4a. However, BI-RADS category 3 masses would not be downgraded, and BI-RADS category 4b or higher masses would not be upgraded.
Statistical analysis
As continuous variables did not follow a normal distribution, the results are reported as medians and interquartile ranges (IQRs). Categorical variables were analysed in terms of frequencies and percentages. The quantitative 2D SWE and 3D SWE elasticity values (ESDE, ESDU and Emax) of benign and malignant masses were compared using the rank-sum test. Paired data of continuous variables in the same masses were compared using the paired rank-sum test. Receiver operating characteristic (ROC) analyses were performed to assess the diagnostic performance of the variables, determine the optimal cut off values using the Youden index (maximum of sensitivity + specificity − 1), and calculate the corresponding sensitivity and specificity. A logistic regression model was used for the ROC analysis of combined data sets (B-mode and SWE variables) and to compare the diagnostic performances of B-mode vs B-mode combined with 2D SWE and B-mode vs B-mode combined with 3D SWE using the area under the ROC curve (AUC) as the indicator of performance. The McNemar test was used to perform paired comparisons of proportions (sensitivity and specificity).
Statistical analyses were performed using dedicated commercial software (SAS, version 9.1.3; SAS, Cary, NC, USA). For multiple pairwise comparisons, p values less than the Bonferroni-corrected significance value of 0.05/9 = 0.0083 were used to indicate statistically significant differences. In other instances, p values less than 0.05 were considered to indicate statistical significance.
Results
Breast masses
There were 73 (34.76%) malignant masses and 137 (65.24%) benign masses detected in our study. Among the cancerous masses, 59 (28.1%) were infiltrating ductal carcinomas, 9 (4.28%) were ductal carcinomas in situ (DCIS), 2 (0.95%) were mucinous carcinomas, 1 (0.48%) was an invasive lobular carcinoma, and 2 (0.95%) were intraductal papillary carcinomas. Among the benign masses, 72 (34.28%) were fibroadenomas, 25 (10%) were fibroadenomatous hyperplasias, 8 (3.81%) were cystic hyperplasias, 11 (5.24%) were papillomas, 6 (2.86%) were adenosis, 7 (3.33%) were mammary duct ectasias, 6 (2.86%) were chronic inflammations, and 2 (0.95%) were fat necrosis. The maximal diameter of the masses by US was 17.04 ± 6.07 mm (range: 4.6–30 mm). The mean size of benign masses was 16.18 ± 5.92 mm (range: 4.6–28.9 mm), and the mean size of malignant masses was 18.95 ± 5.89 mm (range: 7–30 mm).
Quantitative SWE features
ESDE, ESDU, and Emax were significantly higher in malignant masses than in benign masses on both 2D and 3D SWE (p < 0.0001 for all) (Table 1). ESDE was significantly higher than ESDU in both 2D and 3D SWE (p < 0.0001). A comparison of 2D with 3D SWE data revealed that Emax was significantly higher in 3D SWE than in 2D SWE for the same breast masses (p < 0.0001). Both ESDE and ESDU were significantly higher in 3D SWE than in 2D SWE for benign masses (p = 0.0294 and p = 0.0463, respectively), while no significant differences were found in malignant masses (p = 0.735 and p = 0.844, respectively).
Table 1. Medians (IQRs) of elasticity values in kilopascals (kPa) of malignant and benign masses measured on 2D and 3D SWE acquisitions.
Benign | Malignant | p value | |
---|---|---|---|
2D SWE | |||
ESDU | 6.40 (4.37–8.43) | 15.50 (11.63–24.07) | <0.0001 |
ESDE | 6.80 (4.93–9.30) | 21.63 (16.20–27.83) | <0.0001 |
Emax | 42.23 (30.03–51.67) | 139.90 (108.80–177.53) | <0.0001 |
3D SWE | |||
ESDU | 7.00 (5.23–8.80) | 16.23 (11.43–24.97) | <0.0001 |
ESDE | 7.70 (6.00–10.30) | 20.27 (16.53–27.20) | <0.0001 |
Emax | 78.00 (48.00–110.70) | 185.40 (154.90–220.00) | <0.0001 |
2D = two-dimensional, 3D = three-dimensional, SWE = shear wave elastography, IQR = interquartile range.
Diagnostic performance of SWE features
Table 2 summarizes the diagnostic performance of the 2D and 3D SWE features and the results of a comparison between the 2D and 3D SWE features. A comparison of ESDE with ESDU showed that the AUC of ESDE was significantly higher than that of ESDU in both 2D SWE (p = 0.0038) and 3D SWE (p = 0.0057). A comparison of ESDE with Emax revealed that there were no significant differences in the AUC values either in 2D SWE (p = 0.0438) or in 3D SWE (p = 0.6459). A comparison of Emax with ESDU showed that the AUC of Emax was significantly higher than that of ESDU in 2D SWE (p = 0.0016), while there was no significant difference in 3D SWE (p = 0.0676). In a comparison of 2D and 3D SWE data, no significant differences were found in the AUC for either ESDE (0.9553 vs 0.9306, p = 0.026) or ESDU (0.9142 vs 0.8891, p = 0.159). Emax showed a higher AUC in 2D SWE than in 3D SWE (0.9636 vs 0.9252, p = 0.002). The specificity of Emax in 2D SWE was significantly higher than that in 3D SWE (p = 0.000), whereas there were no significant differences for ESDE (p = 0.303) or ESDU (p = 0.060) (Table 2).
Table 2. Diagnostic performances of 2D and 3D SWE for distinguishing benign from malignant breast masses.
AUC | Sensitivity | Specificity | |||||||
---|---|---|---|---|---|---|---|---|---|
2D | 3D | p value | 2D | 3D | p value | 2D | 3D | p value | |
ESDU | 0.9142 | 0.8891 | 0.159 | 58/73 (79.45) | 62/73 (84.93) | 0.387 | 126/137 (91.97) | 116/137 (84.67) | 0.060 |
ESDE | 0.9553# | 0.9306* | 0.026 | 65/73 (89.04) | 61/73 (83.56) | 0.336 | 131/137 (95.62) | 127/137 (92.70) | 0.303 |
Emax | 0.9636& | 0.9252 | 0.002 | 66/73 (90.41) | 65/73 (89.04) | 0.785 | 133/137 (97.08) | 116/137 (84.67) | 0.000 |
The numbers in parentheses are proportions. *p = 0.0057, comparing the AUC of ESDU and ESDE on 3D SWE. #p = 0.0038, comparing the AUC of ESDU and ESDE on 2D SWE. &p = 0.0016, comparing the AUC of ESDU and ESDmax on 2D SWE.
Diagnostic performance of B-mode US and B-mode US combined with SWE
The AUC of the BI-RADS assessments based on B-mode US alone was 0.9064, and the optimal cut off point was between categories 4a and 4b (Table 3). The corresponding sensitivity and specificity were 91.78% (61/73) and 80.92% (110/137), respectively. Adding SWE features to B-mode US significantly improved both the AUC (p < 0.05 for all) and specificity (p < 0.05 for all).
Table 3. Diagnostic performances of B-mode US and B-mode US combined with SWE.
Parameter | Threshold* | AUC | p value# | Sensitivity | Specificity | p value* | PPV | NPV |
---|---|---|---|---|---|---|---|---|
B-mode US categorya | >4a | 0.9064 | NA | 67/73 (91.78) | 110/137 (80.29) | NA | 67/94 (71.28) | 110/116 (94.83) |
+2D SWE | ||||||||
ESDU | >10.73 | 0.9571 | 0.0005 | 63/73 (86.30) | 130/137 (94.89) | 0.0002 | 63/70 (90.00) | 130/140 (92.86) |
ESDE | >13.4 | 0.9683 | 0.0003 | 66/73 (90.41) | 132/137 (96.35) | <0.0001 | 66/71 (92.96) | 132/139 (94.96) |
Emax | >80.8 | 0.9767 | <0.0001 | 65/73 (89.04) | 132/137 (96.35) | <0.0001 | 65/70 (92.86) | 132/140 (94.29) |
+3D SWE | ||||||||
ESDU | >10.23 | 0.9454 | 0.0007 | 60/73 (82.19) | 129/137 (94.16) | 0.0006 | 60/68 (88.24) | 129/142 (90.85) |
ESDE | >13 | 0.9563 | 0.0007 | 62/73 (84.93) | 131/137 (95.62) | <0.0001 | 62/68 (91.18) | 131/142 (92.25) |
Emax | >131.7 | 0.9562 | 0.0016 | 66/73 (90.41) | 122/137 (89.05) | 0.0442 | 66/81 (81.48) | 122/129 (94.57) |
aB-mode US category was defined according to the BI-RADS classification for US. NA = not available. The + before 2D and 3D SWE indicates the effect of adding that SWE feature to the original BI-RADS category 4a and 4b masses. #p value of testing the null hypothesis that there is no change in AUC with the addition of the SWE feature (McNemar test). *p value of testing the null hypothesis that there is no change in specificity with the addition of the SWE feature (McNemar test). *Threshold as the optimal cut off, yielding the maximal sum of the sensitivity and specificity.
Hypothetical effect of SWE on BI-RADS assessments
Among the benign masses, 61.31% (84/137) were recommended to undergo an interventional procedure based on B-mode features only (Table 4). When the ESDU, ESDE and Emax of 2D SWE were included, this percentage significantly decreased to 25.55% (35/137), 21.89% (30/137) and 21.16% (29/137), respectively (p < 0.0001 for all) (Fig. 2). When the ESDU, ESDE and Emax of 3D SWE were included, this percentage significantly decreased to 29.92% (41/137), 23.35% (32/137), and 27.73% (38/137), respectively (p < 0.0001 for all). Among the malignant masses, 98.63% (72/73) were recommended to undergo an interventional procedure based on the B-mode features only. When the SWE features from both 2D and 3D SWE were included, this percentage decreased to 95.85% (70/73) or 97.26% (71/73), which were not significant differences.
Table 4. Estimates of the effect of 2D and 3D SWE features on the biopsy recommendation for breast masses.
BI-RADS 3 | BI-RADS 4a | Biopsy recommendation in the benign group | p value | Biopsy recommendation in the malignant group | p value | |||
---|---|---|---|---|---|---|---|---|
benign masses | malignant masses | benign masses | malignant masses | |||||
B-mode | 46 | 1 | 57 | 5 | 84/137 (61.31) | NA | 72/73 (98.63) | NA |
+2D SWE | ||||||||
ESDU | 95 | 3 | 8 | 3 | 35/137 (25.55) | <0.0001 | 70/73 (95.89) | 0.6198 |
ESDE | 100 | 2 | 3 | 4 | 30/137 (21.89) | <0.0001 | 71/73 (97.26) | 1.0000 |
Emax | 101 | 3 | 2 | 3 | 29/137 (21.16) | <0.0001 | 70/73 (95.89) | 0.6198 |
+3D SWE | ||||||||
ESDU | 89 | 3 | 14 | 3 | 41/137 (29.92) | <0.0001 | 70/73 (95.89) | 0.6198 |
ESDE | 98 | 2 | 5 | 4 | 32/137 (23.35) | <0.0001 | 71/73 (97.26) | 1.0000 |
Emax | 92 | 2 | 11 | 4 | 38/137 (27.73) | <0.0001 | 71/73 (97.26) | 1.0000 |
The numbers in parentheses are percentages. NA = not available. The + before 2D and 3D SWE indicates the effect of adding that the SWE feature to the original BI-RADS category 3 and 4a masses.
Discussion
In this study, quantitative elasticity features were compared between 2D and 3D acquisition techniques. The quantitative values were significantly higher in the malignant masses than in the benign masses on 3D and 2D SWE (p < 0.0001 for all), which was consistent with the results reported by other studies8,27. Berge et al.7 reported that the addition of SWE features to BI-RADS assessments could increase the AUC. Lee et al.28 showed that both 2D and 3D SWE could increase the AUC of diagnostic US imaging. Similarly, in our study, the quantitative elasticity values showed notable diagnostic performance in differentiating benign from malignant breast masses, and the addition of 3D and 2D SWE parameters to B-mode features significantly improved the AUC and specificity of B-mode US alone.
Other studies demonstrated that Emax was the quantitative SWE feature of the optimal performance for breast cancer diagnosis7,33. In our study, Emax showed remarkable performance, with an AUC of 0.943 in 2D SWE. However, the AUC and specificity of Emax in 3D SWE was notably lower than that in 2D SWE (p = 0.002 and p = 0.000). In our study, Emax in 3D SWE was significantly higher than that in 2D SWE for the same breast masses, which was consistent with the findings of a previous study28. Shear wave velocity is susceptible to external compression34. A heavier convex 3D probe may cause higher levels of pressure than a 2D probe27,28. The artefactual stiffness caused by external compression often appears close to the skin side of the elastic image. Using adequate US gel on the surface of the 3D probe and floating the probe gently on the surface of the skin may effectively reduce the occurrence of stress artefacts.
In addition, 3D SWE images were obtained dynamically and automatically and were thus more susceptible to interference from artefacts, which are hereby named “dynamic artefacts”. These artefacts often appear as scattered spots on the SWE image. The artefactual stiffness may involve the centre and periphery of the breast masses, which may be another cause of the higher Emax in 3D SWE. In our study, there were 18 benign masses showing false-positive Emax in 3D SWE caused by the artefactual stiffness but negative Emax in 2D SWE (Fig. 3). The dynamic artefact may be caused by the potential technical error of 3D SWE. Therefore, these artefacts may be the factors that affect the stability of the Emax measurements in 3D SWE and may explain the lower Emax AUC and specificity in 3D SWE.
In this study, ESDE showed a diagnostic accuracy comparable to that of Emax, while ESDU showed a lower AUC than that of Emax in 2D SWE (p = 0.0016). The heterogeneous colour feature was considered useful for differentiating benign from malignant breast lesions25. ESD can serve as a measure of lesion heterogeneity35. In our data, SD showed good diagnostic performance in 2D SWE, which was consistent with the results of a previous study25. In addition, SD did not show any significant differences in diagnostic performance between 2D and 3D SWE. Consequently, the measurement of SD may be relatively stable and less susceptible to the dynamic artefacts of 3D SWE. Moreover, all the elastographic information of the 3D SWE volume could be visualized and measured. SD measured by 3D SWE may better reflect the heterogeneity of the whole tumour mass. In our data, one follow-up decision (category 3) was changed to a biopsy decision (category 4a) after the inclusion of ESDE in both 2D and 3D SWE and Emax in 3D SWE. For the lower diagnostic performance of Emax in 3D SWE, this upgrade caused by Emax in 3D SWE may be distorted by dynamic artefact interference. Therefore, SD measurements may show better stability than Emax measurements in 3D SWE and can be effectively used for differentiating benign from malignant breast masses in 3D SWE.
In our study, ESDE had a higher diagnostic value than ESDU. Compared with ESDU, ESDE provided higher AUCs in 2D SWE (p = 0.0038) and 3D SWE (p = 0.0057). Moreover, the false-negative mass (category 3) was still false negative after adding ESDU in both 2D and 3D SWE. Previous studies have shown inconsistent elastic modulus measurements. Evans et al.29 placed an ROI in the stiffest part of the SWE image, whereas Zhou et al.30 adjusted a round ROI to the lesion contours to encompass the maximum lesion area. In our study, one round ROI was adjusted to the mass contours on SWE images and another was adjusted to the mass contours on greyscale images, ensuring that mass heterogeneity could be depicted (Fig. 1). Then, ESDE and ESDU were measured. Previous studies have shown that tumour-associated stiffness shown by SWE was usually located in the surrounding stroma rather than in the cancerous tissue itself18,29. Due to the attenuation of the shear wave energy in the peritumoural region36 or the low shear wave amplitude and/or noise within the malignant lesion37, the shear wave may not be measurable in these malignant masses. Therefore, the heterogeneity reflected by ESDU, which does not include peritumoural stiffness observed by SWE imaging, may be inaccurate. Moreover, the surrounding desmoplastic reaction and infiltration of the cancer cells into interstitial tissues may be responsible for the stiff zone surrounding the mass on SWE25,29. The stiff rim sign proposed by Zhou et al.30 has shown the best diagnostic performance among all SWE features. As a result, ESDE that includes the mass and immediate adjacent stiff tissue or halo can better illustrate the heterogeneity and thus has a better diagnostic value, especially for malignant masses.
Our results demonstrate that adding SWE features, especially ESDE, to conventional US data is significantly effective for reducing unnecessary interventional procedures. In the benign group, interventional procedures could be avoided in 37.9% (52/137) of the masses after adding the ESDE of 3D SWE and in 39.4% (54/137) of the masses after adding the ESDE of 2D SWE. Recent studies have been focused on the potential of elastography to reduce the number of biopsy procedures performed on benign masses. Lee et al.28 also demonstrated that the elastographic features from 2D and 3D SWE could increase the specificity of US-based diagnosis and decrease the negative biopsy rates. Athanasiou et al.18 reported that by adding quantitative SWE measurements to BI-RADS category 4 lesions, biopsies could be avoided in 46% of the cases. Our results were consistent with the findings of those studies. However, in our data, the biopsy decisions of two masses (category 4a) were changed to follow-up decisions (category 3) after 2D and 3D SWE features were added. The two masses were histopathologically identified as DCIS and were smaller than 1 cm. Other studies have shown that DCIS lesions were softer than invasive cancers8, and soft cancers are frequently small (≤10 mm), screen detected and low grade38. On the B-mode sonograms, the two malignant masses had suspicious morphological features, were irregular and were not circumscribed (Fig. 4). Therefore, whether on 3D or 2D SWE, elastography evaluations should not override the morphological features of malignancies observed on B-mode sonograms, especially for small masses. A comprehensive analysis and further studies with larger populations are of great necessity.
There were several limitations to this study. First, in our study, a multivariate analysis for evaluating confounding factors was not performed. Elasticity values were analysed according to the benign or malignant nature of the breast masses. However, some factors, such as the influences of histological differentiation, lesion size, the existence of microcalcification, the mass depth and the breast thickness, which are widely accepted to influence diagnostic performance39, were not evaluated. Second, selection bias may affect the results of our study because of its retrospective nature and patients being scheduled for biopsy. Third, the inter- and intraobserver variabilities for the elasticity measurements were not evaluated. According to the study design, the images were reviewed by two radiologists together, and disagreements were resolved by consensus. Moreover, a high reproducibility for SWE has previously been reported by several authors, including Cosgrove et al.19, Athanasiou et al.18 and Youk et al.27. Therefore, we assume that the inter- and intraobserver variabilities may not greatly affect the results of our study.
In conclusion, adding quantitative elasticity to B-mode US improved performance and specificity and reduced the occurrence of false-positive biopsies. Compared with Emax, the measurement of SD, especially ESDE, should be more stable given the lower effect of artefacts on 3D SWE. In addition, the measurement of ESDE showed better clinical value than that of ESDU.
Additional Information
How to cite this article: Tian, J. et al. Application of 3D and 2D quantitative shear wave elastography (SWE) to differentiate between benign and malignant breast masses. Sci. Rep. 7, 41216; doi: 10.1038/srep41216 (2017).
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Acknowledgments
We acknowledge Prof Jacques Souquet for his guidance and suggestions regarding the manuscript. We also acknowledge Dr Zhuozhong Wang for his guidance and suggestions regarding the statistical analysis. This study was funded through the Graduate Student Innovating Scientific Research Project of Harbin Medical University of China (No. YJSCX2015-22HYD).
Footnotes
Author Contributions J.T., Q.L. and C.W. designed the research; C.W., P.X. and X.W. performed the ultrasonic imaging of patients and acquired the data; J.T. and Q.L. analysed the data; all the authors discussed the results; all the authors read and commented on the paper; J.T. wrote the paper.
References
- Siegel R., Naishadham D. & Jemal A. Cancer statistics, 2013. CA Cancer J. Clin. 63, 11–30 (2013). [DOI] [PubMed] [Google Scholar]
- Bassett L. W. Imaging of breast masses. Radiol. Clin. North Am. 38, 669–691 (2000). [DOI] [PubMed] [Google Scholar]
- Mendelson E. B. et al. ACR Breast Imaging Reporting and Data System: Breast Imaging Atlas. (American College of Radiology, 2013). [Google Scholar]
- Kim E. K. et al. Clinical application of the BI-RADS final assessment to breast sonography in conjunction with mammography. AJR Am. J. Roentgenol. 190, 1209–1215 (2008). [DOI] [PubMed] [Google Scholar]
- Berg W. A. Supplemental screening sonography in dense breasts. Radiol. Clin. North Am. 42, 845–851 (2004). [DOI] [PubMed] [Google Scholar]
- Corsetti V. et al. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts. Radiol. Med. 111, 440–448 (2006). [DOI] [PubMed] [Google Scholar]
- Berg W. A. et al. Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Radiology 262, 435–449 (2012). [DOI] [PubMed] [Google Scholar]
- Chang J. M. et al. Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases. Breast Cancer Res. Treat. 129, 89–97 (2011). [DOI] [PubMed] [Google Scholar]
- Krouskop T. A., Wheeler T. M., Kallel F., Garra B. S. & Hall T. Elastic moduli of breast and prostate tissues under compression. Ultrason. Imag. 20, 260–274 (1998). [DOI] [PubMed] [Google Scholar]
- Gong X. et al. Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysis. Breast Cancer Res. Treat. 130, 11–18 (2011). [DOI] [PubMed] [Google Scholar]
- Sadigh G., Carlos R. C., Neal C. H. & Dwamena B. A. Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoring. Breast Cancer Res. Treat. 133, 23–35 (2012). [DOI] [PubMed] [Google Scholar]
- Lee J. H. et al. Role and clinical usefulness of elastography in small breast masses. Acad. Radiol. 18, 74–80 (2011). [DOI] [PubMed] [Google Scholar]
- Parajuly S. S., Lan P. Y., Yan L., Gang Y. Z. & Lin L. Breast elastography: a hospital-based preliminary study in China. Asian Pac. J. Cancer Prev. 11, 809–814 (2010). [PubMed] [Google Scholar]
- Cho N. et al. Sonoelastographic strain index for differentiation of benign and malignant nonpalpable breast masses. J. Ultrasound Med. 29, 1–7 (2010). [DOI] [PubMed] [Google Scholar]
- Zhu Q. L. et al. Real-time ultrasound elastography: its potential role in assessment of breast lesions. Ultrasound Med. Biol. 34, 1232–1238 (2008). [DOI] [PubMed] [Google Scholar]
- Tan S. M., Teh H. S., Mancer J. F. & Poh W. T. Improving B mode ultrasound evaluation of breast lesions with real-time ultrasound elastography–a clinical approach. Breast 17, 252–257 (2008). [DOI] [PubMed] [Google Scholar]
- Burnside E. S. et al. Differentiating benign from malignant solid breast masses with US strain imaging. Radiology 245, 401–410 (2007). [DOI] [PubMed] [Google Scholar]
- Athanasiou A. et al. Breast lesions: quantitative elastography with supersonic shear imaging–preliminary results. Radiology 256, 297–303 (2010). [DOI] [PubMed] [Google Scholar]
- Cosgrove D. O. et al. Shear wave elastography for breast masses is highly reproducible. Eur. Radiol. 22, 1023–1032 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sim Y. T., Vinnicombe S., Whelehan P., Thomson K. & Evans A. Value of shear-wave elastography in the diagnosis of symptomatic invasive lobular breast cancer. Clin. Radiol. 70, 604–609 (2015). [DOI] [PubMed] [Google Scholar]
- Kim S. J., Ko K. H., Jung H. K. & Kim H. Shear Wave Elastography: Is It a Valuable Additive Method to Conventional Ultrasound for the Diagnosis of Small (≤2 cm) Breast Cancer? Medicine 94, e1540 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ng W. L. et al. Shearwave Elastography increases diagnostic accuracy in characterization of breast lesions. Medicine 95, e3146 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Park J. et al. Diagnostic performance and colour overlay pattern in shear wave elastography (SWE) for palpable breast mass. Eur. J. Radiol. 84, 1943–1948 (2015). [DOI] [PubMed] [Google Scholar]
- Çebi Olgun D. et al. Use of shear wave elastography to differentiate benign and malignant breast lesions. Diagn. Interv. Radiol. 20, 239–244 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gweon H. M., Youk J. H., Son E. J. & Kim J. A. Visually assessed colour overlay features in shear-wave elastography for breast masses: quantification and diagnostic performance. Eur. Radiol. 23, 658–663 (2013). [DOI] [PubMed] [Google Scholar]
- Evans A. et al. Invasive breast cancer: relationship between shear-wave elastographic findings and histologic prognostic factors. Radiology 263, 673–677 (2012). [DOI] [PubMed] [Google Scholar]
- Youk J. H. et al. Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography. Eur. Radiol. 23, 1519–1527 (2013). [DOI] [PubMed] [Google Scholar]
- Lee S. H. et al. Differentiation of benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional shear-wave elastography. Eur. Radiol. 23, 1015–1026 (2013). [DOI] [PubMed] [Google Scholar]
- Evans A. et al. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses. Breast Cancer Res. 12, R104 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhou J. et al. Breast lesions: evaluation with shear wave elastography, with special emphasis on the “stiff rim” sign. Radiology 272, 63–72 (2014). [DOI] [PubMed] [Google Scholar]
- Barr R. G. et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: part 2: Breast. Ultrasound Med. Biol. 41, 1148–1160 (2015). [DOI] [PubMed] [Google Scholar]
- Liberman L. & Menell J. H. Breast imaging reporting and data system (BI-RADS). Radiol. Clin. North Am. 40, 409–430 (2002). [DOI] [PubMed] [Google Scholar]
- Wang Z. L. et al. Study of quantitative elastography with supersonic shear imaging in the diagnosis of breast tumours. Radiol. Med. 118, 583–590 (2013). [DOI] [PubMed] [Google Scholar]
- Stavros A. T. et al. Solid breast nodules: use of sonography to distinguish between benign and malignant lesions. Radiology 196, 123–134 (1995). [DOI] [PubMed] [Google Scholar]
- Garra B. S. Imaging and estimation of tissue elasticity by ultrasound. Ultrasound Q. 23, 255–268 (2007). [DOI] [PubMed] [Google Scholar]
- Tozaki M. & Fukuma E. Pattern classification of ShearWave™ Elastography images for differential diagnosis between benign and malignant solid breast masses. Acta Radiol. 52, 1069–1075 (2011). [DOI] [PubMed] [Google Scholar]
- Barr R. G. Shear wave imaging of the breast: still on the learning curve. J. Ultrasound Med. 31, 347–350 (2012). [DOI] [PubMed] [Google Scholar]
- Vinnicombe S. J. et al. What are the characteristics of breast cancers misclassified as benign by quantitative ultrasound shear wave elastography? Eur. Radiol. 24, 921–926 (2014). [DOI] [PubMed] [Google Scholar]
- Chang J. M., Moon W. K., Cho N. & Kim S. J. Breast mass evaluation: factors influencing the quality of US elastography. Radiology 259, 59–64 (2011). [DOI] [PubMed] [Google Scholar]