Abstract
The new BD PHOENIX automated microbiology system (Becton Dickinson Diagnostic Systems, Sparks, Md.) is designed for automated rapid antimicrobial susceptibility testing and identification of clinically relevant bacteria. In our study, the accuracy and speed of the BD PHOENIX oxacillin MIC determination for detecting methicillin resistance was evaluated for 200 clinical isolates of coagulase-negative staphylococci (CoNS). Compared to mecA PCR, the BD PHOENIX system detected methicillin resistance with a sensitivity of 99.2%. According to the actual NCCLS oxacillin MIC breakpoint of ≥0.5 μg/ml, the specificity was only 64.9%, attributable to false-positive results in 26 mecA-negative strains, including 16 non-Staphylococcus epidermidis strains. Alternative oxacillin breakpoints of ≥1, ≥2, and ≥4 μg/ml resulted in increased specificities of 83.8, 94.6, and 100% and high sensitivities of 99.2, 99.2, and 96.7%, respectively. Similarly, NCCLS broth microdilution oxacillin MICs exhibited a sensitivity of 100% but a low degree of specificity. However, the previous oxacillin MIC breakpoint of ≥4 μg/ml performed with a sensitivity of 98.4% and a specificity of 98.7%. BD PHOENIX oxacillin MIC results were available after 9 h for 40.5% of the examined CoNS strains and were completed after 17 h. Our results revealed the high reliability of the BD PHOENIX system as a phenotypic method for detection of resistance to oxacillin in mecA-positive CoNS. However, for the improvement of specificity, reevaluation of the optimal oxacillin MIC breakpoint for CoNS appears to be necessary.
Coagulase-negative staphylococci (CoNS) are major nosocomial pathogens ranking today among the five most frequently isolated organisms in nosocomial sepsis and infections related to foreign biomaterials, like intravascular and peritoneal dialysis catheters, cerebrospinal fluid shunts, prosthetic heart valves, and prosthetic joints, vascular grafts, cardiac pacemakers, and intraocular lenses (20, 26, 27, 35, 41, 43).
Frequent multiple antibiotic resistance, and especially the high prevalence of clinical CoNS exhibiting methicillin resistance, has turned treatment of CoNS infection into a therapeutic challenge (2, 10). Methicillin resistance is mediated by an additional low-affinity penicillin binding protein 2a (PBP2a) encoded by the mecA gene (4).
For critically ill patients, vancomycin is the empirical therapy until methicillin resistance is ruled out. However, antistaphylococcal penicillins are the drugs of choice because of unexcelled activity and low toxicity and in order to reduce the possibility of the emergence of vancomycin-resistant CoNS, Staphylococcus aureus, and enterococci (6, 7, 31, 36, 37, 45). Reliable and rapid detection of methicillin resistance is thus indispensable for such “curtailed” antibiotic therapy of patients with CoNS infections. Detection of mecA by PCR is very sensitive and is considered the reference method (33). Alternatively, detection of PBP2a as a marker of methicillin resistance has shown promising results with CoNS and is therefore also recommended (1, 15-17, 25, 33, 44, 48). In contrast, phenotypic detection of methicillin resistance in CoNS is difficult due to the heterogeneous expression of mecA (6, 30, 40, 47). Commonly used tests rely on modified culture conditions to enhance the expression of resistance and take up to 48 h for reliable results (30, 40, 47).
Rapid availability of antimicrobial susceptibility data is likely to result in curtailed antibiotic therapy (9, 42), and lower mortality rates have been reported (9). Some automated systems for susceptibility testing offer the advantage of rapid reporting and improved detection of unusual resistance phenotypes, which is likely to significantly improve intra- and interlaboratory reproducibility. Additionally, financial benefits may result from reduced laboratory costs, fewer diagnostic tests performed, and decreased length of stay for patients in an intensive care unit (3, 9, 12).
In our study, the accuracy and speed of the BD PHOENIX automated microbiology system (Becton Dickinson Diagnostic Systems, Sparks, Md.) for detecting methicillin resistance in CoNS were evaluated by comparing the results of mecA PCR and oxacillin MIC determination by broth microdilution to the results of the BD PHOENIX oxacillin MIC determination for 200 clinical CoNS isolates.
(Part of this work will appear in the doctoral thesis of M. A. Horstkotte, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany.)
MATERIALS AND METHODS
Bacterial isolates.
The CoNS strains in the present study (n = 200) comprise 14 different species (139 S. epidermidis strains, 16 S. haemolyticus strains, 10 S. hominis strains, 9 S. saprophyticus strains, 6 S. capitis strains, 4 S. lugdunensis strains, 4 S. warneri strains, 4 S. xylosus strains, 2 S. schleiferi strains, 2 S. cohnii strains, 1 S. chromogenes strain, 1 S. simulans strain, 1 S. arlettae strain, and 1 S. kloosii strain). All of the strains belong to a collection of clinical CoNS isolated in 1997 and 1998 at the University Hospital Hamburg-Eppendorf. Species identification was performed by using Gram stain morphology, the catalase test, the clumping factor test, and the ID 32 Staph system (bioMérieux, Marcy l' Etoile, France). The strains were characterized for the presence of PBP2a using a commercially available latex agglutination test (Denka Seiken Co., Niigata, Japan) (15) and have been used for evaluation of the new automated VITEK2 system (14). The strains were kept at −80°C in microbank tubes (Pro Lab Diagnostics, Richmond Hill, Ontario, Canada). S. aureus ATCC 29213 (mecA negative) and S. aureus ATCC 43300 (mecA positive) were used for quality control.
PCR for mecA.
BD PHOENIX antimicrobial susceptibility testing.
Methicillin resistance was detected by oxacillin MIC determination (range, ≤0.25 to ≥8 μg/ml) included in the PMIC/ID-6 test panel for gram-positive bacteria (reference no. 448513; Becton Dickinson) of the BD PHOENIX system according to the manufacturer's instructions. Briefly, each isolate was subcultured twice on Columbia agar (Difco, Becton Dickinson) containing 5% sheep blood for 24 h at 37°C before being tested. The BD PHOENIX identification (ID) broth was inoculated with bacterial colonies of the respective isolate adjusted to a 0.5 McFarland standard using a CrystalSpec Nephelometer (Becton Dickinson Diagnostic Systems). An aliquot of 25 μl of the ID suspension was subsequently inoculated into the antimicrobial susceptibility test broth (Becton Dickinson), and 1 drop of the redox indicator resazurin was added. The self-inoculating combination panels were filled, sealed, and loaded into the BD PHOENIX system, where kinetic measurements of both colorimetric and fluorescent signals were collected every 20 min. The results for the BD PHOENIX oxacillin MIC determination were recorded after every hour up to 9 h for each strain. Strains for which the oxacillin MICs were 0.5 to 2 μg/ml or with divergent oxacillin MIC results compared to the PCR for mecA were retested.
Broth microdilution.
Each isolate was subcultured twice on Columbia agar containing 5% sheep blood at 37°C before being tested. Oxacillin MIC results were determined according to the guidelines of the NCCLS (33) with an inoculum of 5 × 105 CFU/ml in cation-adjusted Mueller-Hinton broth (Difco) supplemented with 2% NaCl. The polystyrol microtiter plates with U-shaped wells (Greiner, Kremsmünster, Austria) were incubated at 35°C and read after 24 h.
RESULTS
mecA was detected in 124 of 200 (62%) CoNS strains, with 99 of 140 (70.7%) mecA-positive S. epidermidis strains and 25 of 60 (41.7%) mecA-positive non-S. epidermidis strains.
A BD PHOENIX oxacillin MIC of ≥8 μg/ml was reported for 115 of 123 mecA-positive strains. The BD PHOENIX oxacillin MICs for four mecA-positive strains were 4 μg/ml, whereas those for two mecA-positive S. epidermidis strains and one mecA-positive S. saprophyticus strain were 2 μg/ml. The oxacillin MIC of only one mecA-positive S. epidermidis strain was ≤0.25 μg/ml (Tables 1 and 2).
TABLE 1.
BD PHOENIX oxacillin MICs compared to mecA PCR on the basis of different oxacillin MIC breakpointsa
Oxacillin MIC breakpoint (μg/ml) and strain type | No. of CoNS strains classified as:
|
Sensitivity (%) | Specificity (%) | |
---|---|---|---|---|
Resistant | Susceptible | |||
≥0.5 | ||||
mecA-positive | 122 | 1 | 99.2 | 64.9 |
mecA-negative | 26 | 48 | ||
≥1 | ||||
mecA-positive | 122 | 1 | 99.2 | 83.8 |
mecA-negative | 12 | 62 | ||
≥2 | ||||
mecA-positive | 122 | 1 | 99.2 | 94.6 |
mecA-negative | 4 | 70 | ||
≥4 | ||||
mecA-positive | 119 | 4 | 96.7 | 100 |
mecA-negative | 0 | 74 |
BD PHOENIX oxacillin MICs were not reported initially for 3 of 200 CoNS strains due to insufficient growth of the strains in the test panels. These three strains were not included this analysis.
TABLE 2.
CoNS strains for which BD PHOENIX oxacillin MIC is 0.5 to 2 μg/ml or is discrepant compared to mecA PCR
Strain no. | Species | Oxacillin MIC (μg/ml)
|
mecA PCR | ||
---|---|---|---|---|---|
BD PHOENIX
|
Broth microdilution | ||||
Initially | On repeat testing | ||||
2 | S. epidermidis | 0.5 | ≤0.25 | 0.25 | Negative |
12 | S. epidermidis | 0.5 | ≤0.25 | 0.5 | Negative |
15 | S. epidermidis | 0.5 | No growth | 2 | Negative |
174 | S. epidermidis | 0.5 | ≤0.25 | 0.5 | Negative |
199 | S. haemolyticus | 0.5 | 0.5 | 0.125 | Negative |
64 | S. capitis | 0.5 | 0.5 | 2 | Negative |
8 | S. lugdunensis | 0.5 | 0.5 | 2 | Negative |
89 | S. lugdunensis | 0.5 | ≤0.25 | 0.5 | Negative |
175 | S. lugdunensis | 0.5 | 0.5 | 0.5 | Negative |
7 | S. saprophyticus | 0.5 | 0.5 | 1 | Negative |
9 | S. saprophyticus | 0.5 | 0.5 | 1 | Negative |
48 | S. saprophyticus | 0.5 | 0.5 | 1 | Negative |
177 | S. saprophyticus | 0.5 | 0.5 | 1 | Negative |
95 | S. xylosus | 0.5 | 0.5 | 1 | Negative |
1 | S. epidermidis | 1 | 1 | 0.25 | Negative |
55 | S. epidermidis | 1 | ≤0.25 | 0.25 | Negative |
207 | S. epidermidis | 1 | 0.5 | 1 | Negative |
173 | S. arlettae | 1 | 1 | 2 | Negative |
90 | S. kloosii | 1 | 1 | 4 | Negative |
16 | S. lugdunensis | 1 | 0.5 | 2 | Negative |
3 | S. saprophyticus | 1 | 1 | 2 | Negative |
4 | S. saprophyticus | 1 | 1 | 0.5 | Negative |
50 | S. epidermidis | 2 | 0.5 | 1 | Negative |
52 | S. epidermidis | 2 | ≤0.25 | 0.5 | Negative |
99 | S. epidermidis | 2 | ≤0.25 | 0.5 | Negative |
60 | S. cohnii | 2 | 2 | 2 | Negative |
102 | S. epidermidis | ≤0.25 | ≤0.25 | 8 | Positive |
73 | S. epidermidis | 2 | ≥8 | 4 | Positive |
204 | S. epidermidis | 2 | 1 | 2 | Positive |
96 | S. saprophyticus | 2 | ≥8 | 0.5 | Positive |
The BD PHOENIX system detected an oxacillin MIC of ≤0.25 μg/ml for 48 of 74 mecA-negative CoNS but oxacillin MICs of 0.5, 1, and 2 μg/ml, respectively, for 14, 8, and 4 mecA-negative strains. These higher oxacillin MICs were observed for 10 S. epidermidis strains, 6 S. saprophyticus strains, 4 S. lugdunensis strains, 1 S. xylosus strains, 1 S. capitis strain, 1 S. haemolyticus strain, 1 S. arlettae strain, 1 S. kloosii strains, and 1 S. cohnii strain (Tables 1, 2, 3, and 4).
TABLE 3.
One-to-one comparison of NCCLS broth microdilution oxacillin MIC results with BD PHOENIX oxacillin MIC results in mecA-positive CoNS strainsa
BD PHOENIX oxacillin MIC (μg/ml) | No. of strains at NCCLS broth microdilution oxacillin MIC (μg/ml) of:
|
|||||
---|---|---|---|---|---|---|
≤0.25 | 0.5 | 1 | 2 | 4 | ≥8 | |
≥8 | 6 | 109 | ||||
4 | 1 | 3 | ||||
2 | 1 | 1 | 1 | |||
1 | ||||||
0.5 | ||||||
≤0.25 | 1 |
BD PHOENIX oxacillin MICs were not reported initially for 3 of 200 CoNS strains due to insufficient growth of the strains in the test panels. These three strains were not included this analysis.
TABLE 4.
One-to-one comparison of NCCLS broth microdilution oxacillin MIC results with BD PHOENIX oxacillin MIC results in mecA-negative CoNS strainsa
BD PHOENIX oxacillin MIC (μg/ml) | No. of strains at NCCLS broth microdilution oxacillin MIC (μg/ml) of:
|
|||||
---|---|---|---|---|---|---|
≤0.25 | 0.5 | 1 | 2 | 4 | ≥8 | |
≥8 | ||||||
4 | ||||||
2 | 2 | 1 | 1 | |||
1 | 2 | 1 | 1 | 3 | 1 | |
0.5 | 2 | 4 | 5 | 3 | ||
≤0.25 | 6 | 19 | 17 | 6 |
BD PHOENIX oxacillin MICs were not reported initially for 3 of 200 CoNS strains due to insufficient growth of the strains in the test panels. These three strains were not included this analysis.
The 29 strains for which there were BD PHOENIX oxacillin MICs ranging from 0.5 to 2 μg/ml and the 1 mecA-positive S. epidermidis strain for which there was a BD PHOENIX oxacillin MIC of ≤0.25 μg/ml were retested (Table 2). In the majority of strains, the oxacillin MIC results were within ±1 doubling dilution (Table 2).
For three strains, a mecA-negative S. epidermidis strain, a mecA-negative S. cohnii strain, and a mecA-positive S. epidermidis strain, no BD PHOENIX oxacillin MIC was reported initially due to insufficient growth, but on retesting, the BD PHOENIX oxacillin MICs for the mecA-negative and the mecA-positive S. epidermidis strains were 1 and 4 μg/ml, respectively. For the mecA-negative S. cohnii strain, no BD PHOENIX result was obtained on retesting.
According to the actual resistant NCCLS oxacillin MIC breakpoint of ≥0.5 μg/ml, the BD PHOENIX system detected methicillin resistance in CoNS with a sensitivity of 99.2% and a specificity of 64.9%. Interestingly, the previous NCCLS oxacillin MIC breakpoint of ≥4 μg/ml would have displayed an excellent specificity of 100% and a high sensitivity of 96.7%. Alternative oxacillin MIC breakpoints of ≥1 and ≥2 μg/ml both had a sensitivity of 99.2% with specificities of 83.8 and 94.6%, respectively (Table 2).
Broth microdilution testing among the 124 mecA-positive CoNS strains revealed oxacillin MICs of ≥8 μg/ml for 114 strains, 4 μg/ml for 8 strains, and 2 and 0.5 μg/ml, respectively, for one S. epidermidis and one S. saprophyticus strain (Tables 2, 3, and 4). This resulted in a sensitivity of 100% for the actual resistant NCCLS oxacillin MIC breakpoint of ≥0.5 μg/ml. However, the specificity reached only 13%, with an oxacillin MIC of ≤0.25 μg/ml for 10 of 76 mecA-negative strains, whereas the oxacillin MICs for 27, 25, and 13 strains were 0.5, 1, and 2 μg/ml, respectively. The broth microdilution oxacillin MIC for only one mecA-negative S. kloosii strain was 4 μg/ml (Tables 3 and 4). In contrast, the previous NCCLS oxacillin MIC breakpoint of ≥4 μg/ml performed with an improved specificity of 98.7% and a sensitivity of 98.4%. Alternative oxacillin MIC breakpoints of ≥1 or ≥2 μg/ml displayed a sensitivity of 99.2% and specificities of 48.7 and 81.6%, respectively.
Comparison of BD PHOENIX oxacillin MICs and broth microdilution oxacillin MICs revealed that the MICs were within ±1 doubling dilution (essential agreement) for the majority of the examined strains (Table 3 and 4).
Analysis of the time to results of the BD PHOENIX system revealed that oxacillin MIC results were available after 8 and 9 h in 18.5 and 40.5% of the strains, respectively (Table 5). After 6 or 7 h, mecA-positive strains predominated, but after 8 h, the proportions of mecA-positive CoNS detected as resistant (19.4%) and mecA-negative CoNS reported as susceptible (17.1%) were about equal (Table 5). However, after 9 h, mecA-negative CoNS reported as susceptible outweighed mecA-positive CoNS reported as resistant, with 47.4 versus 36.3% (Table 5). BD PHOENIX oxacillin MIC testing was completed after 17 h (Table 5).
TABLE 5.
Time course of BD PHOENIX oxacillin MIC results in CoNSa
CoNS | No. (%) of strains with reported oxacillin MIC results at (h):
|
|||||
---|---|---|---|---|---|---|
5 | 6 | 7 | 8 | 9 | 17 | |
All | 1 (0.5) | 8 (4) | 21 (10.5) | 37 (18.5) | 81 (40.5) | 197 (98.5) |
mecA positive | 1 (0.8) | 8 (6.5) | 18 (14.5) | 24 (19.4) | 45 (36.3) | 123 (99.2) |
mecA negative | 0 (0) | 0 (0) | 3 (3.9) | 13 (17.1) | 36 (47.4) | 74 (97.4) |
BD PHOENIX oxacillin MICs were not reported initially for 3 of 200 CoNS strains due to insufficient growth of the strains in the test panels. These three strains were not included this analysis.
DISCUSSION
The BD PHOENIX system provides automated antimicrobial susceptibility testing and identification of clinically relevant bacteria and has been evaluated for the identification of Burkholderia cepacia complex isolates and the detection of extended-spectrum beta-lactamases in Escherichia coli and Klebsiella species (5, 22, 38). Recently, the BD PHOENIX system has been tested with a variety of gram-positive bacteria. There was good agreement of oxacillin MIC results for 161 CoNS strains between the BD PHOENIX system and broth microdilution as the reference method (11). However, detailed information about discrepant strains was lacking and mecA PCR was performed only for strains already categorized as resistant by the oxacillin MIC, rendering exact determination of sensitivity and specificity difficult. The time until detection of methicillin resistance was not addressed.
In our study, the new BD PHOENIX system proved to be a highly reliable phenotypic method for detecting mecA-positive CoNS strains as resistant to oxacillin. Based on the current NCCLS oxacillin MIC breakpoint of ≥0.5 μg/ml, the BD PHOENIX oxacillin MIC exhibited an excellent sensitivity of 99.2% but a rather low specificity of 64.9% (Table 1). These findings were supported by the broth microdilution results, which exhibited an excellent sensitivity of 100% but a specificity of 13%. However, evaluation of the two oxacillin MIC determination methods with higher breakpoints would have shown a favorable performance.
In 1999, the NCCLS lowered the oxacillin MIC breakpoint for CoNS from ≥4 to ≥0.5 μg/ml (33, 40). Subsequently, several investigators found high sensitivity of the new breakpoint for S. epidermidis, S. hominis, and S. haemolyticus but described reduced specificity for S. saprophyticus, S. cohnii, S. xylosus, S. warneri, and S. lugdunensis strains (13, 19, 25, 34, 40). Concordantly, in our study, six S. saprophyticus strains, four S. lugdunensis strains, one S. xylosus strain, one S. cohnii strain, one S. capitis strain, one S. arlettae strain, and one S. kloosii strain were mecA negative, but the BD PHOENIX oxacillin MICs for the strains ranged from 0.5 to 2 μg/ml. The classification of these 15 isolates was confirmed by broth microdilution results (Table 2).
Similarly, decreased specificity of the actual breakpoint was described for the Vitek automated system (bioMérieux), predominantly due to mecA-negative S. saprophyticus and S. lugdunensis and to a minor extent to S. cohnii, S. sciuri, and S. capitis strains (18, 25, 29, 34, 46). The new VITEK 2 system (bioMérieux) showed high sensitivity (14, 21, 23, 24), and concordance between mecA PCR and VITEK 2 oxacillin MICs was observed for almost all S. epidermidis, S. haemolyticus, and S. hominis strains (14, 23). However, the specificities varied considerably, between 97 and 80%, due to false-positive results, especially for mecA-negative S. saprophyticus, S. cohnii, and S. lugdunensis strains (14, 23).
It is notable that in our study BD PHOENIX oxacillin MICs of 0.5, 1, and 2 μg/ml were reported for four, three, and three mecA-negative S. epidermidis strains, respectively, as well as for one mecA-negative S. haemolyticus strain (Table 2). Broth microdilution would have classified 4 of these 11 isolates as susceptible (Table 2). Essential agreement between the oxacillin MICs in the two methods was recorded for four of the remaining seven strains, which all had to be classified as resistant (Table 2). The 10 (7.2%) mecA-negative S. epidermidis strains for which the oxacillin MICs were ≥0.5 μg/ml, out of a total of 139 S. epidermidis strains, represent a proportion similar to that in another study, which found 2 of 37 (5.4%) S. epidermidis strains for which the oxacillin MICs were ≥0.5 μg/ml (30).
For epidemiological reasons, study populations vary in their species compositions and strains differ in their phenotypic expression of methicillin resistance. Consequently, a range of oxacillin MIC breakpoints for resistance have been proposed. Until 1999, the NCCLS recommended an oxacillin MIC breakpoint for resistance in all staphylococci of ≥4 μg/ml, but ≥2 (47) or ≥1 (8, 30) μg/ml was advocated as more appropriate for CoNS. An even lower oxacillin MIC breakpoint of ≥0.5 μg/ml, suggested by two other investigators (28, 40), was adopted for CoNS by the NCCLS in 1999.
The inoculum size is crucial for oxacillin MIC determination. Despite adherence to the NCCLS protocol, the inoculum was clearly below the target concentration of 5 × 105 CFU/ml for all CoNS species except S. lugdunensis in a large multicenter study (33, 40). Interestingly, the recorded mean numbers of CFU per milliliter were lower for S. epidermidis, S. hominis, and S. haemolyticus than for S. saprophyticus, S. capitis, and S. lugdunensis (40), which correlates with the higher oxacillin MICs described in several studies for the last three species despite their being mecA negative.
Subtle changes in the test conditions, e.g., the source of the Mueller-Hinton medium, have been reported to affect oxacillin MIC results for CoNS (40). The BD PHOENIX antimicrobial susceptibility test broth contains 0.01% Tween 80, which may explain some discrepancies in oxacillin MIC results.
Mechanisms of oxacillin resistance independent of mecA may be responsible for oxacillin MIC results of 0.5 to 2 μg/ml for mecA-negative strains. Alterations in PBPs other than PBP2a have been described in S. haemolyticus and S. saprophyticus (39) and have been suggested as one explanation for this phenomenon (40). Alternatively, S. saprophyticus and S. lugdunensis, and probably certain other CoNS species, might inherently display a higher oxacillin MIC despite lacking mecA.
To improve the specific detection of methicillin resistance in CoNS, exclusion of S. saprophyticus and S. lugdunensis strains was recommended (25), and this proposal was adopted in part by the NCCLS, which no longer recommends routine oxacillin susceptibility testing of S. saprophyticus isolated from urine (33).
However, this issue cannot be fully resolved by the exclusion of S. saprophyticus and S. lugdunensis strains or by the recommendation of the NCCLS to additionally analyze CoNS strains other than S. epidermidis which cause severe infections for the presence of either PBP2a or mecA and to consider strains lacking these markers as susceptible. PCR for mecA is both laborious and costly, whereas false-positive PBP2a latex agglutination tests have been observed for mecA-negative S. warneri, S. lugdunensis, S. simulans, and S. hominis strains but not S. epidermidis strains (1, 15, 16, 44, 48). The question of whether penicillinase-resistant penicillins can eradicate severe infections due to mecA-negative CoNS for which the oxacillin MICs are 0.5 to 2 μg/ml is unresolved. Clinical trials with strains of S. lugdunensis, which is now regarded as an important pathogen in native valve endocarditis (32), or S. saprophyticus causing complicated urinary tract infection are needed.
In our study, all CoNS strains for which the BD PHOENIX oxacillin MICs were 0.5 or 1 μg/ml did not harbor mecA, in contrast to three out of seven strains for which the oxacillin MIC was 2 μg/ml. In another study, mecA PCR results and the presence of PBP2a have been found to be identical in these CoNS strains (15). We conclude that CoNS strains for which the critical BD PHOENIX oxacillin MIC is 2 μg/ml should be examined for the presence of PBP2a or mecA. Further investigations are warranted to clarify whether differential, species-specific oxacillin MIC breakpoints of ≥2 μg/ml for S. saprophyticus and S. lugdunensis (19, 40) and ≥0.5 μg/ml for S. epidermidis and other CoNS species are more appropriate.
An optimized antibiotic regimen can result in lower mortality (9, 42). Therefore, antimicrobial test results should be accessible on the day of testing. Evaluation of the speed of the BD PHOENIX system for providing oxacillin MIC results revealed at least equivalence to those of other phenotypic methods. After 9 h, results for ∼41% of the CoNS strains were reported, and oxacillin MIC testing was completed after 17 h (Table 5).
Acknowledgments
We thank Rainer Laufs for his continuous support. Becton Dickinson (Heidelberg, Germany) kindly provided the BD PHOENIX automated microbiology system.
This work was supported in part by a grant from the Deutsche Forschungsgemeinschaft given to D.M.
REFERENCES
- 1.Andrews, J. M., F. J. Boswell, and R. Wise. 2000. Establishing MIC breakpoints for coagulase-negative staphylococci to oxacillin. J. Antimicrob. Chemother. 45:259-261. [DOI] [PubMed] [Google Scholar]
- 2.Archer, G. L., and M. W. Climo. 1994. Antimicrobial susceptibility of coagulase-negative staphylococci. Antimicrob. Agents Chemother. 38:2231-2237. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Barenfanger, J., C. Drake, and G. Kacich. 1999. Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing. J. Clin. Microbiol. 37:1415-1418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Berger-Bächi, B. 1997. Resistance not mediated by β-lactamase (methicillin resistance), p. 158-174. In K. B. Crossley and G. L. Archer (ed.), The staphylococci in human disease. Churchill Livingston, New York, N.Y.
- 5.Brisse, S., S. Stefani, J. Verhoef, A. van Belkum, P. Vandamme, and W. Goessens. 2002. Comparative evaluation of the BD PHOENIX and VITEK 2 automated instruments for identification of isolates of the Burkholderia cepacia complex. J. Clin. Microbiol. 40:1743-1748. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Chambers, H. F. 1997. Methicillin resistance in staphylococci: molecular and biochemical basis and clinical implications. Clin. Microbiol. Rev. 10:781-791. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Chang, S., D. M. Sievert, J. C. Hageman, M. L. Boulton, F. C. Tenover, F. P. Downes, S. Shah, J. T. Rudrik, G. R. Pupp, W. J. Brown, D. Cardo, and S. K. Fridkin. 2003. Infection with vancomycin-resistant Staphylococcus aureus containing the vanA resistance gene. N. Engl. J. Med. 348:1342-1347. [DOI] [PubMed] [Google Scholar]
- 8.Cormican, M. G., W. W. Wilke, M. S. Barrett, M. A. Pfaller, and R. N. Jones. 1996. Phenotypic detection of mecA-positive staphylococcal blood stream isolates: high accuracy of simple disk diffusion tests. Diagn. Microbiol. Infect. Dis. 25:107-112. [DOI] [PubMed] [Google Scholar]
- 9.Doern, G. V., R. Vautour, M. Gaudet, and B. Levy. 1994. Clinical impact of rapid in vitro susceptibility testing and bacterial identification. J. Clin. Microbiol. 32:1757-1762. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Edmond, M. B., S. E. Wallace, D. K. McClish, M. A. Pfaller, R. N. Jones, and R. P. Wenzel. 1999. Nosocomial bloodstream infections in United States hospitals: a three-year analysis. Clin. Infect. Dis. 29:239-244. [DOI] [PubMed] [Google Scholar]
- 11.Fahr, A. M., U. Eigner, M. Armbrust, A. Caganic, G. Dettori, C. Chezzi, L. Bertoncini, M. Benecchi, and M. G. Menozzi. 2003. Two-center collaborative evaluation of the performance of the BD PHOENIX automated microbiology system for identification and antimicrobial susceptibility testing of Enterococcus spp. and Staphylococcus spp. J. Clin. Microbiol. 41:1135-1142. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Ferraro, M. J., and J. H. Jorgensen. 1999. Susceptibility testing instrumentation and computerized expert systems for data analysis and interpretation, p. 1593-1600. In P. R. Murray, E. J. Baron, M. A. Pfaller, F. C. Tenover, and R. H. Yolken (ed.), Manual of clinical microbiology. American Society for Microbiology, Washington, D.C.
- 13.Gradelski, E., L. Valera, L. Aleksunes, D. Bonner, and J. Fung-Tomc. 2001. Correlation between genotype and phenotypic categorization of staphylococci based on methicillin susceptibility and resistance. J. Clin. Microbiol. 39:2961-2963. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Horstkotte, M. A., J. K. M. Knobloch, H. Rohde, S. Dobinsky, and D. Mack. 2002. Rapid detection of methicillin resistance in coagulase-negative staphylococci with the VITEK 2 system. J. Clin. Microbiol. 40:3291-3295. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Horstkotte, M. A., J. K. M. Knobloch, H. Rohde, and D. Mack. 2001. Rapid detection of methicillin resistance in coagulase-negative staphylococci by a penicillin binding protein 2a-specific latex agglutination test. J. Clin. Microbiol. 39:3700-3702. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Hussain, Z., L. Stoakes, S. Garrow, S. Longo, V. Fitzgerald, and R. Lannigan. 2000. Rapid detection of mecA-positive and mecA-negative coagulase-negative staphylococci by an anti-penicillin binding protein 2a slide latex agglutination test. J. Clin. Microbiol. 38:2051-2054. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Hussain, Z., L. Stoakes, M. A. John, S. Garrow, and V. Fitzgerald. 2002. Detection of methicillin resistance in primary blood culture isolates of coagulase-negative staphylococci by PCR, slide agglutination, disk diffusion, and a commercial method. J. Clin. Microbiol. 40:2251-2253. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Hussain, Z., L. Stoakes, R. Lannigan, S. Longo, and B. Nancekivell. 1998. Evaluation of screening and commercial methods for detection of methicillin resistance in coagulase-negative staphylococci. J. Clin. Microbiol. 36:273-274. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Hussain, Z., L. Stoakes, V. Massey, D. Diagre, V. Fitzgerald, S. El Sayed, and R. Lannigan. 2000. Correlation of oxacillin MIC with mecA gene carriage in coagulase-negative staphylococci. J. Clin. Microbiol. 38:752-754. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Kloos, W. E. 1997. Taxonomy and systematics of staphylococci indigenous to humans, p. 113-137. In K. B. Crossley and G. L. Archer (ed.), The staphylococci in human disease. Churchill Livingston, New York, N.Y.
- 21.Leclercq, R., M. H. Nicolas-Chanoine, P. Nordmann, A. Philippon, P. Marchais, A. Buu-Ho, H. Chardon, H. Dabernat, F. Doucet-Populaire, C. Grasmick, P. Legrand, C. Muller-Serieys, J. Nguyen, M. C. Ploy, M. E. Reverdy, M. Weber, and R. J. Courcol. 2001. Multicenter evaluation of an automated system using selected bacteria that harbor challenging and clinically relevant mechanisms of resistance to antibiotics. Eur. J. Clin. Microbiol. Infect. Dis. 20:626-635. [DOI] [PubMed] [Google Scholar]
- 22.Leverstein-van Hall, M. A., A. C. Fluit, A. Paauw, A. T. Box, S. Brisse, and J. Verhoef. 2002. Evaluation of the Etest ESBL and the BD Phoenix, VITEK 1, and VITEK 2 automated instruments for detection of extended-spectrum beta-lactamases in multiresistant Escherichia coli and Klebsiella spp. J. Clin. Microbiol. 40:3703-3711. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Ligozzi, M., C. Bernini, M. G. Bonora, M. De Fatima, J. Zuliani, and R. Fontana. 2002. Evaluation of the VITEK 2 system for identification and antimicrobial susceptibility testing of medically relevant gram-positive cocci. J. Clin. Microbiol. 40:1681-1686. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Livermore, D. M., M. Struelens, J. Amorim, F. Baquero, J. Bille, R. Canton, S. Henning, S. Gatermann, A. Marchese, H. Mittermayer, C. Nonhoff, K. J. Oakton, F. Praplan, H. Ramos, G. C. Schito, J. Van Eldere, J. Verhaegen, J. Verhoef, and M. R. Visser. 2002. Multicenter evaluation of the VITEK 2 Advanced Expert System for interpretive reading of antimicrobial resistance tests. J. Antimicrob. Chemother. 49:289-300. [DOI] [PubMed] [Google Scholar]
- 25.Louie, L., A. Majury, J. Goodfellow, M. Louie, and A. E. Simor. 2001. Evaluation of a latex agglutination test (MRSA-Screen) for detection of oxacillin resistance in coagulase-negative staphylococci. J. Clin. Microbiol. 39:4149-4151. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Mack, D. 1999. Molecular mechanisms of Staphylococcus epidermidis biofilm formation. J. Hosp. Infect. 43(Suppl.):S113-S125. [DOI] [PubMed] [Google Scholar]
- 27.Mack, D., K. Bartscht, S. Dobinsky, M. A. Horstkotte, K. Kiel, J. K. M. Knobloch, and P. Schäfer. 2000. Staphylococcal factors involved in adhesion and biofilm formation on biomaterials, p. 307-330. In Y. H. An and R. J. Friedman (ed.), Handbook for studying bacterial adhesion: principles, methods, and applications. Humana Press, Totowa, N.J.
- 28.Marshall, S. A., W. W. Wilke, M. A. Pfaller, and R. N. Jones. 1998. Staphylococcus aureus and coagulase-negative staphylococci from blood stream infections: frequency of occurrence, antimicrobial susceptibility, and molecular (mecA) characterization of oxacillin resistance in the SCOPE program. Diagn. Microbiol. Infect. Dis. 30:205-214. [DOI] [PubMed] [Google Scholar]
- 29.Martinez, F., L. J. Chandler, B. S. Reisner, and G. L. Woods. 2001. Evaluation of the Vitek card GPS105 and VTK-RO7.01 software for detection of oxacillin resistance in clinically relevant coagulase-negative staphylococci. J. Clin. Microbiol. 39:3733-3735. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.McDonald, C. L., W. E. Maher, and R. J. Fass. 1995. Revised interpretation of oxacillin MICs for Staphylococcus epidermidis based on mecA detection. Antimicrob. Agents Chemother. 39:982-984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Murray, B. E. 2000. Vancomycin-resistant enterococcal infections. N. Engl. J. Med. 342:710-721. [DOI] [PubMed] [Google Scholar]
- 32.Mylonakis, E., and S. B. Calderwood. 2001. Infective endocarditis in adults. N. Engl. J. Med. 345:1318-1330. [DOI] [PubMed] [Google Scholar]
- 33.National Committee for Clinical Laboratory Standards. 2003. Performance standards for antimicrobial susceptibility testing; 13th informational supplement. M100-S13. National Committee for Clinical Laboratory Standards, Wayne, Pa.
- 34.Ramotar, K., W. Woods, and B. Toye. 2001. Oxacillin susceptibility testing of Staphylococcus saprophyticus using disk diffusion, agar dilution, broth microdilution, and the Vitek GPS-105 card. Diagn. Microbiol. Infect. Dis. 40:203-205. [DOI] [PubMed] [Google Scholar]
- 35.Rupp, M. E., and G. L. Archer. 1994. Coagulase-negative staphylococci: pathogens associated with medical progress. Clin. Infect. Dis. 19:231-243. [DOI] [PubMed] [Google Scholar]
- 36.Small, P. M., and H. F. Chambers. 1990. Vancomycin for Staphylococcus aureus endocarditis in intravenous drug users. Antimicrob. Agents Chemother. 34:1227-1231. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Smith, T. L., M. L. Pearson, K. R. Wilcox, C. Cruz, M. V. Lancaster, B. Robinson-Dunn, F. C. Tenover, M. J. Zervos, J. D. Band, E. White, W. R. Jarvis, et al. 1999. Emergence of vancomycin resistance in Staphylococcus aureus. N. Engl. J. Med. 340:493-501. [DOI] [PubMed] [Google Scholar]
- 38.Stürenburg, E., I. Sobottka, H. H. Feucht, D. Mack, and R. Laufs. 2003. Comparison of BDPhoenix and VITEK2 automated antimicrobial susceptibility test systems for extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella species clinical isolates. Diagn. Microbiol. Infect. Dis. 45:29-34. [DOI] [PubMed] [Google Scholar]
- 39.Suzuki, E., K. Hiramatsu, and T. Yokota. 1992. Survey of methicillin-resistant clinical strains of coagulase-negative staphylococci for mecA gene distribution. Antimicrob. Agents Chemother. 36:429-434. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Tenover, F. C., R. N. Jones, J. M. Swenson, B. Zimmer, S. McAllister, and J. H. Jorgensen. 1999. Methods for improved detection of oxacillin resistance in coagulase-negative staphylococci: results of a multicenter study. J. Clin. Microbiol. 37:4051-4058. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Thylefors, J. D., S. Harbarth, and D. Pittet. 1998. Increasing bacteremia due to coagulase-negative staphylococci: fiction or reality? Infect. Control Hosp. Epidemiol. 19:581-589. [DOI] [PubMed] [Google Scholar]
- 42.Trenholme, G. M., R. L. Kaplan, P. H. Karakusis, T. Stine, J. Fuhrer, W. Landau, and S. Levin. 1989. Clinical impact of rapid identification and susceptibility testing of bacterial blood culture isolates. J. Clin. Microbiol. 27:1342-1345. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.U.S. Department of Health and Human Services. 2000. National Nosocomial Infections Surveillance (NNIS) system report, data summary from January 1992-April 2000, issued June 2000. Am. J. Infect. Control 28:429-448. [DOI] [PubMed] [Google Scholar]
- 44.Udo, E. E., E. M. Mokadas, A. Al Haddad, B. Mathew, L. E. Jacob, and S. C. Sanyal. 2000. Rapid detection of methicillin resistance in staphylococci using a slide latex agglutination kit. Int. J. Antimicrob. Agents 15:19-24. [DOI] [PubMed] [Google Scholar]
- 45.Wilson, W. R., A. W. Karchmer, A. S. Dajani, K. A. Taubert, A. Bayer, D. Kaye, A. L. Bisno, P. Ferrieri, S. T. Shulman, D. T. Durack, et al. 1995. Antibiotic treatment of adults with infective endocarditis due to streptococci, enterococci, staphylococci, and HACEK microorganisms. JAMA 274:1706-1713. [PubMed] [Google Scholar]
- 46.Yamazumi, T., I. Furuta, D. J. Diekema, M. A. Pfaller, and R. N. Jones. 2001. Comparison of the Vitek gram-positive susceptibility 106 card, the MRSA-Screen latex agglutination test, and mecA analysis for detecting oxacillin resistance in a geographically diverse collection of clinical isolates of coagulase-negative staphylococci. J. Clin. Microbiol. 39:3633-3636. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.York, M. K., L. Gibbs, F. Chehab, and G. F. Brooks. 1996. Comparison of PCR detection of mecA with standard susceptibility testing methods to determine methicillin resistance in coagulase-negative staphylococci. J. Clin. Microbiol. 34:249-253. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Zbinden, R., M. Ritzler, E. Ritzler, and B. Berger-Bächi. 2001. Detection of penicillin-binding protein 2a by rapid slide latex agglutination test in coagulase-negative staphylococci. J. Clin. Microbiol. 39:412. [DOI] [PMC free article] [PubMed] [Google Scholar]