Skip to main content
Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry logoLink to Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry
. 1976 Jun 1;80A(3):389–399. doi: 10.6028/jres.080A.038

Fluorescence Quantum Yield Measurements*

J B Birks 1
PMCID: PMC5293345  PMID: 32196267

Abstract

Four molecular fluorescence parameters describe the behaviour of a fluorescent molecule in very dilute (~ 10−6M) solution:

  1. the fluorescence spectrum FM(v¯);

  2. the fluorescence polarization PM;

  3. the radiative transition probability kFM; and

  4. the radiationless transition probability kIM.

    These parameters and their temperature and solvent dependence are those of primary interest to the photophysicist and photochemist. FM(v¯) and PM can be determined directly, but kFM and kIM can only be found indirectly from measurements of the secondary parameters,

  5. the fluorescence lifetime τM, and

  6. the fluorescence quantum efficiency qFM,

where kFM=qFMM and kIM=(1–qFM) τM.

The real fluorescence parameters F(v¯), τ and ϕF of more concentrated (c > 10−5 M) solutions usually differ from the molecular parameters FM(v¯), τM and qFM due to concentration (self) quenching, so that τ > τM and ϕF < qFM. The concentration quenching is due to excimer formation and dissociation (rates kDMc and kMD, respectively) and it is often accompanied by the appearance of an excimer fluorescence spectrum FD(v¯) in addition to FM(v¯), so that F(v¯) has two components. The excimer fluorescence parameters FD(v¯), PD, kFD and kID together with kDM and kMD, and their solvent and temperature dependence, are also of primary scientific interest.

The observed (technical) fluorescence parameters FT(v¯), τT and ϕFT in more concentrated solutions usually differ from the real parameters F(v¯), τ and ϕF, due to the effects of self-absorption and secondary fluorescence. The technical parameters also depend on the optical geometry and the excitation wavelength. The problems of determining the real parameters from the observed, and the molecular parameters from the real, will be discussed.

Methods are available for the accurate determination of FT(v¯) and τT. The usual method of determining ϕFT involves comparison with a reference solution R, although a few calorimetric and other absolute determinations have been made. For two solutions excited under identical conditions and observed at normal incidence

ϕFTϕFRT=n2FT(v¯)dv¯nR2FRT(v¯)dv¯

where n is the solvent refractive index.

Two reference solution standards have been proposed, quinine sulphate in N H2SO4 which has no self-absorption, and 9,10-diphenylanthracene in cyclohexane which has no self-quenching. The relative merits of these solutions will be discussed, and possible candidates for an “ideal” fluorescence standard with no self-absorption and no self-quenching will be considered.

Keywords: Fluorescence lifetime, fluorescence quantum efficiency, fluorescence quantum yields, fluorescence spectrum, fluorescence standards, molecular fluorescence parameters, observed (technical) fluorescence parameters, polarization, radiative and non-radiative transition probabilities, real fluorescence parameters

1. Introduction

Most atoms, molecules, polymers and crystals emit ultraviolet, visible or infrared photons following excitation of their electronic energy levels. This emission or luminescence is classified according to the mode of excitation:

  • photoluminescence due to optical (non-ionizing) radiation;

  • cathodoluminescence due to cathode rays (electron beams);

  • radioluminescence (scintillations) due to ionizing radiation;

  • electroluminescence due to electric fields;

  • thermoluminescence produced thermally after prior irradiation by other means;

  • triboluminescence due to frictional and electrostatic forces;

  • sonoluminescence due to ultrasonic radiation;

  • chemiluminescence due to a chemical process, commonly oxidation;

  • electrochemiluminescence due to a chemical process, initiated by an electric field; and

  • bioluminescence due to a biological process, usually enzymatic in origin.

  • Luminescent materials can be divided into several broad groups.

  1. Aromatic molecules constitute the largest group. They emit luminescence in the vapour, liquid, polymer and crystal phases and in fluid and rigid solutions [1]1. They are used extensively in organic liquid, plastic and crystal scintillators [2], luminescent dyes and paints, detergent and paper whiteners, luminescent screens, dye lasers, etc.

  2. Many inorganic crystals, including diamond, ruby, alkali halides, zinc sulphide and calcium tungstate, luminesce efficiently. The emission is usually from impurity centres (activators) or, in the absence of such impurities, from crystal defects [2]. Luminescent inorganic crystals are used as scintillators [2], luminescent screens, solid-state lasers, jewels, etc.

  3. Noble gases (He, Ne, Ar, Kr, Xe) luminesce in the vapour, liquid, and solid phases and in liquid and solid solutions [2, 3]. They are used in discharge lamps, gas lasers and scintillators.

  4. Many simple inorganic molecules luminesce in the vapour phase [4]. Some, like H2, D2, N2, and Hg are used in discharge lamps; others, like N2, I2, and CO2 are used in gas lasers.

  5. Some inorganic ions, notably those of the rare earth elements, are luminescent. They are used as activators in inorganic crystals (see (ii) above), glasses and chelates. Applications include inorganic crystal and glass scintillators and Nd glass lasers.

  6. Many biological molecules are luminescent. These include
    1. aromatic amino-acids (tryptophan, tyrosine, phenylalanine) in proteins;
    2. nucleotides (adenine, guanine, uracil, cytosine, thymine) in DNA and RNA;
    3. retinyl polyenes in the visual pigments;
    4. chlorophylls and carotenoids in the photosynthetic chloroplast; and
    5. several vitamins and hormones.

    The study of biomolecular luminescence is an important area of biophysical research [5].

  7. Aliphatic molecules, such as the paraffins and cyclohexane, once considered to be nonluminescent, are now known to emit in the far ultraviolet (~ 200 nm) with low quantum yield [6]. This list, which is not exhaustive, illustrates the wide range of luminescent materials and their applications.

2. Luminescence of Aromatic Molecules

2.1. Radiative transitions

The initial discussion is limited to aromatic molecules (i), but it will be later extended to other luminescent materials (ii)–(vii). Most aromatic molecules have an even number of π-electrons, giving a ground singlet electronic state S0 in which the electron spins are paired. The excited π electronic states of the molecule are either

  • singlet states: S1, S2Sp; or

  • triplet states: T1, T2Tq.

A spin-allowed radiative transition (luminescence) between two states of the same multiplicity (e.g. S1 → So, SpS0, TqT1) is called fluorescence (F). A spin-forbidden radiative transition between two states of different multiplicity (e.g. T1S0) is called phosphorescence (P). The energy difference between the initial and final electronic state is emitted as a fluorescence photon (hvF) or phosphorescence photon (hvp).

The fluorescence occurring immediately after the initial excitation of S1 (or Sp) is known as prompt fluorescence. In some molecules or molecular systems there are mechanisms by which S1 (or Sp) may become excited subsequent to the initial excitation, resulting in delayed fluorescence. The two principal mechanisms are as follows [1].

  1. Thermal activation of molecules in the lowest triplet state T1, which is long-lived because the T1S0 transition is spin-forbidden, repopulates the fluorescent singlet state S1, resulting in E-type (eosin-type) delayed fluorescence, so called because it occurs in eosin and other dye molecules.

  2. Diffusional interaction between pairs of T1-excited molecules in solution or T1 excitons in a crystal creates singlet-excited molecules by the process
    T1+T1S1(orSp)+S0 (1)
    resulting in P-type (pyrene-type) delayed fluorescence, so called because it occurs in pyrene and other aromatic hydrocarbons.

2.2. Radiationless Transitions

Radiative transitions are between electronic states of different energy. In a complex molecule or crystal there are also radiationless transitions between different electronic states of the same energy. These isoenergetic radiationless transitions are induced by molecular or crystal vibrations.

A spin-allowed radiationless transition between two states of the same multiplicity is called internal conversion (IC). A spin-forbidden radiationless transition between two states of different multiplicity is called intersystem crossing (ISC).

2.3. Vibrational Relaxation

After the initial excitation or after an isoenergetic radiationless transition, the molecule is usually in a vibronic state Sp* (or Tq*) corresponding to a vibrationally-excited level of a particular electronic state Sp (or Tq). In a condensed medium (solution, liquid, polymer, crystal) or a high-pressure vapour the excess vibrational energy Sp*Spo (or Tq*Tqo) is rapidly dissipated collisionally to the environment leading to vibrational relaxation (VR).

The dissipative VR process, which is distinct from the nondissipative IC and ISC processes, plays an essential role in the thermal equilibration of the excited molecules. At normal temperatures VR is rapid (~ 10−12–10−13 s, depending on the excess vibrational energy to be dissipated) and much faster than IC, ISC, F or P.

Isolated excited molecules in a low-pressure vapour, where VR is inhibited by the low collision rate, behave in a different manner than those in the condensed phase [6]. In an isolated molecule the fluorescence occurs from the vibronic state Sp* initially excited or from isoenergetic vibronic states S1*, S2*. of lower electronic states populated by IC. This phenomena is called resonance fluorescence. In the condensed phase VR brings the excited molecules rapidly into thermal equilibrium and all the processes (F, P, IC and ISC) occur from an equilibrated system of molecules.

2.4. Photophysical Processes and Parameters

Figure 1 shows schematically the photophysical processes that can occur in an aromatic molecular system in very dilute solution (~ 10−6 M) following excitation into S2.

Figure 1. Schematic diagram of radiative (solid vertical lines), radiationless (wavy horizontal lines), and vibrational relaxation (broken vertical lines) transitions between electronic states (solid horizontal lines) S2, S1, T1 and S0 of an aromatic molecule in a condensed medium.

Figure 1

F = fluorescence, P = phosphorescence, IC = internal conversion, ISC = intersystem crossing, VR = vibrational relaxation.

S2 decays by

  1. IC to S1*, followed by VR to S1;

  2. IC to S0***, followed by VR to S0; or

  3. S2S0 fluorescence F2.

    S1→S1 fluorescence, which could potentially occur, is forbidden since S2 and S1 have the same parity (ungerade) [1].

    S1, from (a), decays by

  4. S1S0 fluorescence F1;

  5. ISC to T1*, followed by VR to T1; or

  6. IC to S0**, followed by VR to S0.

    T1, from (e), decays by

  7. T1S0 phosphorescence P; or

  8. ISC to S0*, followed by VR to S0

F, P, IC and ISC are the rate-determining processes, since VR is much faster, kAB is defined as the rate parameter of the B → A process, where B is the initial state and A is the product radiation (F or P) or final state (for IC or ISC) [1]. Subscripts G = S0, T=T1, M = S1, and H = S2 indicate the different states. Figure 2 shows the rate parameters corresponding to the processes of figure 1. In the rate parameter description the VR subsequent to each IC or ISC is omitted, but the distinction between the isoenergetic radiationless transitions and the vibrational relaxation should not be overlooked.

Figure 2. Rate parameters of radiative transitions (solid vertical lines) and radiationless plus vibrational relaxation transitions (1broken vertical lines) between electronic states (solid horizontal lines) S2, S1, T1, and S0 of an aromatic molecule in a condensed medium.

Figure 2

The notation of the states, radiations and rate parameters is indicated.

The S2, S1 and T1 decay parameters are given by

kH=kFH+kMH+kGH=1/τH (2)
kM=kFM+kTM+kGM=1/τM (3)
kT=kPT+kGT=1/τT (4)

where τH, τM and τT are the S2, S1 and T1 lifetimes, respectively.

The quantum efficiency qAB of any photophysical process, rate kAB, from an excited state B is defined as the fraction of the excited molecules in B that decay by that process, so that

qAB=kAB/kB (5)

The S2S0 and S1S0 fluorescence quantum efficiencies are, respectively.

qFH=kFH/kH (6)
qFM=kFM/kM (7)

the T1 → S0 phosphorescence quantum efficiency is

qPT=kPT/kT (8)

the S2S1* internal conversion quantum efficiency is

qMH=kMH/kH (9)

and the S1T1* and T1S1* intersystem crossing quantum efficiencies are, respectively,

qTM=kTM/kM (10)
qGT=kGT/kT (11)

The rate parameters (fig. 2), the decay parameters and lifetimes (2)(4), and the quantum efficiencies (5)(11) are molecular parameters. They refer to very dilute (~ 10−6M) solutions, containing no dissolved oxygen or other impurity quenchers.

An increase in the solution molar concentration c does not change the unimolecular rate parameters, but it introduces bimolecular processes due to interactions between excited molecules in S2, S1 or T1 and unexcited molecules in So, producing concentration quenching. To a first approximation the S2, S1 and T1 concentration quenching rates may be expressed as kCHc, kCMc and kCTc, and the S2, S1 and T1 decay parameters become

kH=kH+kCHc=1/τH (2a)
kM=kM+kCMc=1/τM (3a)
kT=kT+kCTc=1/τT (4a)

respectively, where τH, τM and τT are the S2, S1 and T1 lifetimes in a solution of molar concentration c. An exact treatment also considers the rate parameters of the excimers produced by the concentration quenching and their dissociation [1], but the Stern-Volmer approximation of (2a)–(4a) is adequate for the present discussion.

The quantum yield ϕ of any photophysical process in a solution of concentration c is defined in the same manner as the quantum efficiency, except that the limitation to very dilute solutions is removed. The S2S0 and S1S0 fluorescence quantum yields are, respectively

ϕFH=kFHkH+kCHc=qFH1+KCHc (12)
ϕFM=kFMkM+kCMc=qFM1+KCMc (13)

and the T1S0 phosphorescence quantum yield is

ϕPT=kPTkT+kCTc=qPT1+KCTc (14)

The parameters KCH(= kCH/kH), KCM(= kCM/kM) and KCT(kCT/kT) are the Stern-Volmer coefficients of concentration quenching of S2, S1 and T1, respectively.

The S2S1* internal conversion quantum yield is

ϕMH=kMHkH+kCHc=qMH1+KCHc (15)

and the S1T1* and T1S0* intersystem crossing quantum yields are, respectively,

ϕTM=kTMkM+kCMc=qTM1+KCMc (16)
ϕGT=kGTkT+kCTc=qGT1+KCTc (17)

The above expressions for quantum efficiencies and yields all refer to direct excitation of the state from which the process occurs, and they require revision when the state is not excited directly. Thus for excitation into S2, the S1S0 fluorescence quantum yield is

ϕFMH=ϕMHϕFM (18)

For excitation into S1, the T1S0 phosphorescence quantum yield is

ϕPTM=ϕTMϕPT (19)

2.5. Vavilov’s Law and Kasha’s Rules

It is commonly assumed that ϕMH = 1.0 for S2S1* IC and that ϕ=1 for IC between higher excited states within the singlet (Sp) manifold, so that ϕFM is independent of the excitation wavelength λex up to the ionization potential. This assumption, known as Vavilov’s law, has been confirmed for many compounds in solution. Major deviations from Vavilov’s law have, however, been observed for solutions of benzene, toluene, p-xylene, mesitylene, fluorobenzene, naphthalene, 2-methylnaphthalene, 1,6-dimethylnaphthalene [1], tryptophan, tyrosine and phenylalanine [7]. In each case it is observed that ϕFMH/ϕFM=ϕMH<1. In benzene and its derivatives and possibly in the other compounds, the effect is due to efficient S2S0*** IC (kGH) competing with S2S1* IC (kMH) [8]. In fluorescence quantum yield measurements it is essential either to verify that Vavilov’s law applies, or to limit the excitation to the region of the S0S1 absorption spectrum.

Kasha’s rules [9], another well-known generalization, state that in a complex molecule luminescence occurs only from the lowest excited state of a given multiplicity, i.e., S1S0 fluorescence and T1S0 phosphorescence. For many years azulene and its derivatives, which emit S2S0 fluorescence and negligible S1S0 fluorescence, were the main exceptions to Kasha’s rules. Recently the picture has changed dramatically.

In addition to the normal S1S0 fluorescence, weak S2S0 fluorescence has been observed in benzene, toluene, p-xylene, mesitylene, naphthalene, pyrene, 1:2-benzanthracene, 3:4-benzopyrene, 1:12-benzoperylene and ovalene, weak S3S0 fluorescence has been observed in p-xylene, mesitylene, naphthalene, pyrene and 1:2-benzanthracene, and weak S4S0 fluorescence has been observed in pyrene and fluoranthene [6, 10].

Such fluorescence from higher excited states was predicted by the author in 1954 [11]. Its detection is difficult, since it occurs in the region of the S0Sp absorption spectrum, and its quantum yield is only ~ 10−5 ϕFM [6]. Subsequent attention will be focused on the main S1S0 fluorescence.

2.6. The Fluorescence Spectrum

The S1S0 fluorescence spectrum occurs from a system of S1 excited molecules in thermal equilibrium in solution. The fraction of these molecules with vibrational energy Ev is proportional to exp (−Ev/kT), where k is Boltzmann’s constant and T is the absolute temperature. A large majority are in the zero point level S10, and to a first approximation the fluorescence of the “hot” molecules can be disregarded.

The S10S0 fluorescence occurs into S00, the zeropoint level of S0, and into the many vibrational levels of So. The S10S00 transition, or 0–0 fluorescence transition, of wavenumber (v¯00)F is the highest energy transition in the S10S0 fluorescence spectrum. In the vapour (v¯00)F coincides with (v¯00)A, the corresponding S00S10 0–0 absorption transition. In solution, due to solvent polarization effects

(v¯00)A(v¯00)F=Δv¯00 (20)

where Δv¯00 varies from 0 to a few hundred cm−1 depending on the solvent [1]. In benzene the 0–0 fluorescence and absorption transitions are symmetry-forbidden and they are absent from the vapour spectra. They appear as weak solvent-induced bands (the Ham bands) in solution spectra, the intensity depending on the solvent [1].

At low temperatures the S1S0 (=S10S0) fluorescence spectrum FM(v¯) consists of a complex series of a few hundred narrow lines of different intensities, which may be analysed into progressions and combinations of the different vibrational modes of the unexcited molecule. When the temperature is increased, thermal broadening and solvent-solute interactions obscure most of the vibrational structure. At room temperature FM(v¯) commonly consists of a few prominent broad bands with little other structure. Thus FM(v¯) for anthracene in cyclohexane solution consists of a progression of 5 broad bands, spaced about 1400 cm−1 apart, corresponding to CC vibrational modes. Similar vibrational progressions occur in FM(v¯) for other condensed hydrocarbons [1], For large molecules, e.g., dyes, with many degrees of vibrational and/or rotational freedom, FM(v¯) at room temperature often consists of a single broad band with no vibrational structure. Berlman [12] has recorded the fluorescence spectra of many aromatic molecules.

The solvent has a strong influence on FM(v¯) at room temperature. In a polar solvent like ethanol the vibrational bands are broad and poorly resolved, and the separation Δv¯00 between the absorption and fluorescence 0–0 hands is relatively large. In a nonpolar aliphatic hydrocarbon solvent, like cyclohexane or n-hexane, the spectral resolution is improved and Δv¯00 is reduced. In a fluorocarbon solvent, like perfluoro-n-hexane (PFH), each of the vibrational bands has a well-resolved fine structure, similar to that in the vapour phase, and Δv¯00=0 [13]. PFH is an ideal spectroscopic solvent, apart from cost and the low solubility of aromatic molecules in PFH.

At temperatures above about −100 °C the “hot” vibrationally-excited S1 molecules with a Boltzmann distribution of energies S1*(=S10+Ev) also contribute to FM(v¯). Each component S1*S0 spectrum is similar to the S10S0 spectrum, except that it is shifted by an amount Ev towards higher energies, and its intensity is proportional to exp (−Ev/kT). Most of the S1*S0 spectral distribution lies below the S10S0 spectrum and is obscured thereby. However, each component S1*S0 spectrum extends beyond Δv¯00 to Δv¯00+Ev, giving rise to hot fluorescence bands, the intensity and extent of which increase with temperature. These hot fluorescence bands, which are an integral part of the S1S0 fluorescence spectrum FM(v¯) at room temperature, occur in all aromatic molecules, although they are not often recorded. The emission bands are in the same region as the S0S1 absorption, and special care is needed to observe them [6].

2.7. The rate parameters

Observations of qFM and τM for a very dilute solution enable

kFM=qFM/τM (21)
kIM=kFM+kGM=(1qFM)τM (22)

to be determined. Birks and Munro [14] have reviewed methods of measuring τM. Observations of qTM (= kTM/kM), by one of the several methods described by Wilkinson [15], enable kTM and kGM to be evaluated. The measurement of qPT and τT permits kPT and kGT to be determined [1]. Thus measurements of five quantities qFM, τM, qTM, qPT and τT are required to determine the five S1 and T1 unimolecular rate parameters kFM, kTM, kGM, kPT and kGT.

Observations of τM and τT (or ϕFM and ϕPT) as a function of the molar concentration c enable the bimolecular rate parameters kCM and kCT to be determined. The observations and analysis may be extended further to obtain the fluorescence (kFD), ISC (kTD), IC(kGD) and dissociation (kMD) rate parameters of the singlet excimer [1]. This involves observations of the molecular (ϕFM) and excimer (ϕFD) fluorescence quantum yields of concentrated solutions.

It is the rate parameters and their dependence on temperature, solvent, substitution etc. that are the quantities of interest to the photophysicist and photochemist, and not the properties from which they are derived. The latter may be of technical interest for particular applications. Of the three quantities qFM, τM and qTM required to determine the S1 rate parameters kFM, kTM and kGM the published values of qFM (or ϕFM which is often implicitly equated to qEM) show the largest scatter. When the solution concentration c is increased, self-absorption effects introduce difficulties in the determination of ϕFM. It is hoped that this paper will help to improve the situation.

2.8. The Fluorescence Rate Parameter

A theoretical expression for kFM has been derived from the Einstein radiation relation using the zero-order Born-Oppenheimer approximation [16, 17]

kFMt=2.88×109nF3nAv¯F3Av1ϵ(v¯)dv¯v¯ (23)

where nF and nA are the mean refractive indices of the solvent over the S1S0 fluorescence and S0S1 absorption spectra, respectively, v¯F3Av1 is the reciprocal of the average value of v¯3 over the fluorescence spectrum, ϵ(v¯) is the decadic molar extinction coefficient, and the integral is taken over the S0S1 absorption spectrum. Relation (23) has been tested for a number of molecules, and excellent agreement between kFM and kFMt has been obtained for several molecules in different laboratories [1, 12, 16, 17, 18]. Such molecules may be useful as fluorescence standards.

If the solvent optical dispersion is small nFnA = n, and (23) can be simplified to

kFMt=n2(kFMt)0 (24)

where (kFMt) is a molecular constant, independent of the solvent and the temperature. Relation (24) has been verified for several solutes in different solvents over a wide temperature range [19].

In some molecules there are large discrepancies between kFM and kFMt. A detailed study of these anomalies has revealed the presence of electronic states not observed spectroscopically [20, 21]. The nature and origin of such radiative lifetime anomalies are discussed elsewhere [22]. The factors determining the other S1 and T1 rate parameters kTM, kGM, kPT and kGT have been considered previously [1, 6, 8].

2.9. Molecular Fluorescence Parameters

The S1S0 fluorescence of an aromatic compound in very dilute solution is characterized by the following molecular parameters.

  1. The fluorescence spectrum FM(v¯) depends on the solvent and temperature (see 2.6).

  2. The fluorescence polarization pM depends on the direction of the transition dipole moment relative to the molecular axes. For a π*π electronic transition this lies in the molecular plane along one of two orthogonal axes depending on the symmetry of S1. For naphthalene the fluorescence is long-axis polarized; for anthracene it is short-axis polarized [1].

  3. The fluorescence rate parameter kFM is proportional to the square of the transition dipole moment [1]. In the absence of any anomalies kFM/n2 is independent of the solvent and temperature (24).

  4. The S1 radiationless rate parameter kIM (= kTM + kGM) describes the processes competing with the fluorescence. kIM usually depends markedly on the solvent and on the temperature [1].

    FM(v¯) and pM can be observed directly. The evaluation of kFM and kIM involves measurements of two secondary parameters:

  5. The fluorescence lifetime τM; and

  6. the fluorescence quantum efficiency qFM.

    Several accurate methods are available for measuring τM [14]. Reliable methods are available for measuring qFM, but they are often used incorrectly [23].

    The molecular fluorescence parameters FM(v¯), pM, kFM and kIM are independent of the molar concentration c. The secondary fluorescence parameters τM and ϕFM decrease with increase in c due to

  7. the concentration quenching rate parameter kCM.

kCM, which depends markedly on the solvent viscosity and the temperature, is a further molecular parameter of photophysical interest.

3. Other Luminescent Materials

The preceding discussion of the luminescence of aromatic molecules is applicable to the other luminescent materials considered in the Introduction. It applies directly to biological molecules (vi) and aliphatic organic molecules (vii). Noble gases (iii) also have singlet ground states, and there are close analogies between them and the aromatic hydrocarbons, particularly in excimer formation [3]. There are no radiationless transitions in the noble gases (qFM= qFH= 1.0) because of the absence of internal vibrations. They form excimers in the vapour, liquid, and solid phases, and the vibrational modes of these may generate radiationless transitions and vibrational relaxation in the condensed phase [3].

Simple inorganic molecules (iv) are similar. They normally have singlet ground states and excited singlet and triplet states. Although they have internal vibrations, the vibronic state density is low, and there are normally no radiationless transitions except at high excitation energies, where predissociation may occur [4].

The luminescence of inorganic crystals (ii) and inorganic ions (v) in a solid matrix is closely related to that of aromatic molecular crystals. Unfortunately there are major terminological differences between inorganic crystal photophysics and organic molecular crystal photophysics. Table 1 is based on a brief survey of the inorganic luminescence literature, and may require revision in the light of any recent changes.

Table 1.

Terminology of photo physical processes

Process Organic Inorganic



1. Luminescence,
 (a) spin-allowed Fluorescence (F) Fluorescence
 (b) spin-forbidden Phosphorescence (P) Fluorescence
 (c) thermally-activated delayed E-type delayed fluorescence Phosphorescence
2. Radiationless transition
(a) spin-allowed Internal conversion (IC)
(b) spin-forbidden Intersystem crossing (ISC)
3. Vibrational relaxation Vibrational relaxation (VR)
4. Radiationless transition plus vibrational relaxation IC (or ISC) and VR Multiphonon process

The inorganic luminescence terminology predates the discovery of electron spin, and it has not been adjusted to take account of this. Because of spin, processes 1(a) and 1(b) differ in lifetime by a factor of up to 108, and it would seem appropriate to distinguish them. In 1933 Jablonski [24], the originator of figure 1, showed that the two slow emissions 1(b) and 1(c) observed in organic dyes originated from a common metastable state X, and he proposed that they be called β-phosphorescence and α-phosphorescence, respectively. Since 1944 when Lewis and Kasha [25] demonstrated that X=T1, the lowest excited triplet state, 1(b) has been called simply phosphorescence, while 1(c) which has the same emission spectrum as 1(a) is called E-type delayed fluorescence.

Standardization of luminescence terminology is long overdue. Those responsible for organizing international luminescence conferences and publishing luminescence journals have unfortunately neglected to formulate a scientific language common to workers in organic and inorganic luminesqence. Perhaps the National Bureau of Standards can assist in the matter.

4. Fluorescence Measurements

4.1. Fluorescence Spectra

A true (corrected) fluorescence spectrum is plotted as the relative quantum intensity FM(v¯) (relative number of quanta per unit wave-number interval) against wavenumber v¯. A few spectrometers have been developed which record directly the true fluorescence spectrum. The majority provide spectra which require correction for the dispersion of the analyzing monochromator, the spectral response of the photomultiplier or detector, and any light losses. This involves the preparation of an instrumental calibration curve, by measurements

  1. with a calibrated lamp through a neutral filter;

  2. with a thermopile or bolometer;

  3. of reference solution fluorescence spectra [26]; or

  4. with a fluorescent quantum counter.

A quantum counter is a system which has a constant fluorescence quantum yield over a broad spectral range. To achieve this it should have a high and relatively constant absorption over the spectral range of interest, it should have negligible self-absorption (no overlap of fluorescence and absorption spectrum), it should obey Vavilov’s law, and it should be stable photochemically. Systems commonly used as quantum counters include:

  1. 3 gl−1 Rhodamine B in ethylene glycol (210–530 nm),

  2. 4 gT−1 quinine sulphate in N H2SO4 (220–340 nm), and

  3. 10−2M 1-dimethylaminonaphthalene 5-(or 7-) sodium sulphonate in 0.1 N Na2CO3 (210–400 nm).

An extension of this list would be advantageous.

Three common optical geometries are used in fluorescence measurements;

  1. front-surface or reflection geometry, in which the fluorescence from the irradiated surface of the specimen is observed;

  2. 90° geometry, in which the fluorescence is observed in a direction normal to the incident beam; and

  3. transmission geometry, in which the fluorescence is observed from the opposite side of the speciment to the excitation.

For very dilute solutions (~ 10−6M) the three geometries give the same fluorescence spectrum, quantum efficiency and lifetime. The 90° geometry, used by Birks and Dyson [17] and others, has the advantage of minimizing background incident light and of allowing the fraction of incident light absorbed in the specimen to be monitored directly.

An increase in the solution concentration c reduces qFM and τM to ϕFM and τM, respectively, due to concentration quenching. It also attenuates the high-energy region of FM(v¯) due to self-absorption arising from the overlap of the absorption and fluorescence spectra. As c is increased the intensity of the 0–0 fluorescence band decreases towards zero due to its overlap with the 0–0 absorption band. At room temperature and high c the self-absorption may extend to the 0–1 and 0–2 fluorescence bands, which overlap the 1–0 and 2–0 hot absorption bands, due to thermally activated molecules in the first and second vibrational levels of S0. These self-absorption effects are a maximum in the transmission geometry (c), somewhat reduced in the 90° geometry (b), and they are least in the reflection geometry (a), which is normally used for fluorescence studies of more concentrated solutions.

The effect of self-absorption on FM(v¯) observed in reflection can be minimized by Berlman’s technique [12] of excitation at an intense absorption maximum, thereby minimizing the penetration depth dex of the exciting light. This technique does not, however, compensate for the secondary fluorescence produced by the self-absorption and which modifies ϕFM and τM, as discussed below.

4.2. Fluorescence Quantum Yields

Absolute determinations of fluorescence quantum yields have been made using integrating spheres to collect the fluorescence emission over a full 4π solid angle, by calorimetry to distinguish radiative processes from radiationless processes and vibrational relaxation, by actinometry to integrate fight intensities photochemically, and by polarization and scattering measurements. These methods have been reviewed by Lipsett [27] and Demas and Crosby [28].

The superscript T is introduced to refer to the observed (technical) fluorescence parameters FMT(v¯), ϕFMT and τMT, which may differ from the true fluorescence parameters FM(v¯), ϕFM and τM, due to self-absorption and secondary fluorescence. Absolute determinations of ϕFM are difficult and uncommon, and it is normal practice to measure ϕFMT by comparison with a standard of known fluorescence quantum yield ϕFRT. If FMT(v¯) and FTT(v¯) are the corrected fluorescence spectra of the specimen and standard, respectively, excited under identical conditions (same excitation wavelength, optical density and geometry) and observed at normal incidence in reflection, then

ϕFMTϕFRT=n20FMT(v¯)dv¯nR20FRT(v¯)dv¯ (25)

where n and nR are the refractive indices of the specimen solution and the standard solution, respectively. The integrations are often made using a quantum counter [28].

The refractive index term is a correction for the solution optical geometry. The angular dependence of the fluorescence flux F(ϕ) from a small isotropically emitting source behind an infinite plane surface in a medium of refractive index n is

F(ϕ)=F0(cosϕ)n1(n2sin2ϕ)1/2 (26)

where F0 is a constant (ϕFMT) and F(ϕ) is the flux (in quanta cm2 s−1) falling on a small aperture at an angle ϕ from the normal to the face. For ϕ = 0° (26) reduces to

F(0)=F0/n2 (27)

leading to (25). Relation (26) has been verified by Melhuish [29] who recommended the use of cuvettes with blackened back and sides for fluorescence yield measurements to minimize internal reflection errors.

Shinitzky [30] has pointed out a further potential source of error in fluorescence quantum yield and lifetime measurements. When a fluorescent system is excited by unpolarized fight and its emission is detected without a polarizer, the emission intensity has a typical anisotropic distribution which is directly related to its degree of polarization. This effect can introduce an error of up to 20 percent in all fluorescence quantum yield and lifetime measurements, but it is eliminated when the fluorescence is detected at an angle of 55° or 125° to the direction of excitation, provided that the emission detection system is unbiased with respect to polarization. Procedures for the elimination of polarization errors for partially polarized excitation and biased detection systems were developed by Cehelnik, Mielenz, and Velapoldi [31] and Mielenz, Cehelnik, and McKenzie [32].

If n and nR differ, it is recommended that the specimen and reference solutions be excited at 55° incidence angle and observed at normal incidence, to eliminate the polarization effect and simplify the refractive index correction. The latter correction disappears if n = nR, and the excitation and front-face observation directions need only differ by 55°. The angles of incidence and “reflection” should differ to minimize scattered light.

The self-absorption attenuates the high-energy end of FM(v¯), but it does not affect the low-energy end. If FM(v¯), observed in very dilute solution, and FMT(v¯), observed at molar concentration c, are normalized in the low-energy region, then the parameter

a=AMAMTAM (28)

where

AM=0FM(v¯)dv¯ (29)
AMT=0FMT(v¯)dv¯ (30)

represents the self-absorption probability. This normalization procedure, introduced for anthracene crystal fluorescence [33], has been applied by Birks and Christophorou [34] to concentrated solutions of aromatic hydrocarbons. Substitution of AM in place of AMT in (25) gives ϕFM in place of ϕFMT For materials of low ϕFM (< 0.3), the linear Stern-Volmer plots of qFM/ϕFM against c of gradient KCM (13) confirm the validity of the procedure, which corresponds to assuming

ϕFMT=(1a)ϕFM (31)

This relation neglects the secondary fluorescence resulting from the self-absorption. Allowing for this, the author [11, 35] has shown that

ϕFMT=(1a)ϕFM1aϕFM (32)

which approximates to (31) when FM ≪ 1, and that

τMT=τM1aϕFM. (33)

Relation (33) is considered to be generally valid. Relation (32) is considered to he valid for the transmission and 90° geometries. It is also valid for the reflection geometry, except for specimens of high ϕFm. Under the latter conditions the secondary fluorescence contributes markedly to the observed fluorescence intensity, so that ϕFMT>ϕFM in reflection, although ϕFMT<ϕFM in transmission as predicted by (32). Figure 3 plots Melhuish’s observations [36] of ϕFMT as a function of c for 9,10-diphenylanthracene (DPA) in benzene solution, excited at 366 nm with front-face observation. Due to secondary fluorescence ϕFMT increases from qFM = 0.83 in very dilute solution to ϕFMT=1.0 at c ⩾ 1.5×10−3M. Correction for self-absorption and secondary fluorescence, using a much more complex relation than (32), showed that ϕFM = 0.83 ±0.02 over the whole range of c, thus demonstrating that DPA is immune to concentration quenching [36].

Figure 3. 9,10-diphenylanthracene in benzene.

Figure 3

Front-surface observation at λex=:365 nm. Technical fluorescence quantum yield ϕFMT (+) and true fluorescence quantum yield ϕFM (o) against molar concentration c. Data from Melhuish [36].

The secondary fluorescence contribution to ϕFMT increases with decrease in the excitation penetration depth dex. Berlman’s [12] choice of an intense absorption hand for excitation (λex = 265 nm for DPA) minimizes dex. This minimizes the effect of self-absorption on FMT(v¯), but it also maximizes the effect of secondary fluorescence on ϕFMT. To reduce the latter, a weak absorption region should be chosen for excitation, and c should be kept as low as possible.

To summarize, there are no particular problems in determining ϕFM for (a) very dilute solutions (b) more concentrated solutions observed in the transmission or 90° geometries, and (c) more concentrated solutions of ϕFM<~0.3 observed in the reflection geometry. The effects of self-absorption and secondary fluorescence are, however, difficult to compensate in concentrated solutions of high ϕFM observed in the reflection geometry. One simple solution is to abandon the reflection geometry and to observe such systems in the more tractable transmission geometry. The alternative is to utilize one of the numerous mathematical relations, some simple [11, 35], some complex [27, 36], which have been developed to describe self-absorption and secondary fluorescence.

4.3. Fluorescence Standards

Melhuish [36] proposed the use of a 5 × 10−3M solution of quinine bisulphate (QS) in 1N sulphuric acid as a fluorescence standard. From careful measurements he obtained ϕFM = 0.510 for c = 5×10−3M increasing to qFM = 0.546 at infinite dilution at 25 °C. The value of ϕFM at any other concentration can be evaluated using the Stern-Volmer relation (13). The QS solution is stable under prolonged irradiation, its fluorescence is not quenched by dissolved air (unlike most aromatic molecules), and it has a very small over-lap of the absorption and fluorescence spectra. It suffers from three minor disadvantages:

  1. concentration quenching;

  2. the temperature coefficient of ϕFM is about − 0.25 percent per degree over the range 10° to 40° C; and

  3. sulphuric acid is not a conventional solvent for aromatic molecules and this necessitates using the refractive index correction in (25).

Nevertheless the QS standard, and various secondary standards derived therefrom, have been adopted in this and many other laboratories [28, 37]. Quinine is the fluorescent entity, and the use of quinine sulphate in place of the bisulphate does not appear to effect the values of qFM and ϕFM [28]. Unfortunately many authors have chosen to use 0.1 N sulphuric acid as the solvent, rather than 1 N as recommended by Melhuish [36], while assuming his fluorescence quantum yield values to be unchanged. There is evidence that ϕFM increases by 6–8 percent on increasing the solvent normality from 0.1 N to 1 N [28].

Table 2 lists comparative data on τM and qFM for very dilute solutions of several aromatic compounds obtained using the QS standard [1618]. The consistency of the data from three different laboratories is gratifying. The close agreement between the experiment values of kFM(= qFM/τM) and the theoretical values of kFMt from (23) for several compounds shows the error in qFM for the QS standard to be small. Gelernt et al. [36] have recently calorimetrically determined qFM for QS in 1 N sulphuric acid at 25 °C. The calorimetric value of qFM = 0.561 (±0.039) agrees satisfactorily with the fluorimetric value of qFM = 0.546 [34]. Other fluorescence standards have been discussed by Demas and Crosby [28].

Table 2.

Fluorescence lifetimes (τM) and quantum efficiencies (qFM) of very dilute solutions

Compound Solvent τM (ns) qFM kFM/kFMt Ref.






Quinine Bisulphate 1N H2SO4 20.1 0.54   0.73   [17]
1N H2SO4 19.4 .54   .75   [18]
Perylene benzene   4.9 .89   .93   [17]
benzene   4.79 .89   .90   [16]
benzene   5.02 .89   .90   [18]
Acridone ethanol 11.8 .83   1.02   [16]
ethanol 12.5 .825   1.05   [18]
9-Aminoacridine ethanol 13.87 .99   1.15   [16]
ethanol 15.15 .99   1.02   [18]
9,10-Diphenyl anthracene benzene   7.3 .85   0.99   [17]
benzene   7.37 .84   .98   [18]

Berlman [12] used a 10−3M solution of 9,10-diphenyl-anthracene (DPA) in cyclohexane, excited at 265 nm (an absorption maximum) and observed in reflection, as a fluorescence standard. Under these conditions the DPA solution has a technical fluorescence quantum yield of ϕFMT=1.0, due to self-absorption and secondary fluorescence, although the true fluorescence quantum yield is ϕFM = qFM = 0.83 (±0.02) (fig. 3). Relation (25) requires that the specimen and standard be compared under identical conditions of excitation and optical density, so that the 10−3M DPA solution standard is only suitable for observations of ϕFMT on concentrated solutions in reflection geometry. The QS standard is more versatile since it does not limit the specimen concentration or optical geometry.

Berlman [12] observed τMT with heterochromatic excitation and FMT(v¯) with monochromatic excitation (these parameters need to be observed under identical conditions for (32) and (33) to be applicable [35]). He evaluated ϕFMT by comparison with FRT(v¯) for the DPA standard observed under similar conditions, although the optical densities and excitation wavelengths of the specimen and standard appear to have differed. Apart from the usual hot band elimination and some 0–0 band attenuation, FMT(v¯) approximates to the molecular spectrum FM(v¯). ϕFMT and τMT do not correspond to qFM and τM, as implicitly assumed by Berlman [12], who used them to “evaluate” kFM. They require correction for self-absorption and secondary fluorescence to obtain ϕFM and τM, and these parameters need correction for concentration quenching to obtain qFM and τM. Birks [1] tried to correct Berlman’s ϕFMT data [12] by renormalizing them to qFR = 0.83 for DPA, but this procedure has since been shown to be invalid [23].

It is of interest to note the effect of substituting different fluorescence parameters in the relations used to evaluate kFM and kIM. From (3a), (13), (21), (22), (32) and (33)

qFMτM=ϕFMτM=kFM (34)
ϕFMTτMT=(1a)kFM (35)
(1qFM)τM=kIM (36)
(1ϕFM)τM=(1ϕFMT)τMT=kIM+kCMc. (37)

An ideal fluorescence standard for aromatic solutions should

  1. have no self-absorption,

  2. have no concentration quenching,

  3. be in a common solvent suitable for other aromatic molecules (to eliminate the refractive index correction),

  4. be readily available as a high-purity material (or be insensitive to impurities), and

  5. be photochemically stable.

QS satisfies (iv) and (v) and it approximates closely to (i), but it does not satisfy (ii) and (iii). DPA meets criteria (ii)–(v), but it exhibits strong self-absorption. To minimize self-absorption in an aromatic hydrocarbon solution it is necessary that S1 is a 1Lb state, so that the S0S1 absorption is weak, and not a 1La state, giving strong S0S1 absorption, as in DPA [1]. There are two hydrocarbons which exhibit no concentration quenching (ii), have S=1Lb so that self-absorption (i) is reduced, and satisfy (iii) and (v). These compounds, phenanthrene and chrysene, merit consideration as fluorescence standards. They can be obtained, but are not yet readily available, as high- purity materials (iv).

Aromatic excimers satisfy all the criteria for a fluorescence standard, since they have no self-absorption (i) or concentration quenching (ii) [1]. In concentrated solutions the excimer spectrum FD(v¯) can be readily distinguished from the attenuated monomer spectrum FMT(v¯) [34], although the presence of the latter may be undesirable. It can be eliminated by the use of a pure liquid or crystal. A pyrene crystal has ϕFD = qFD = 1.0 at low temperatures and ϕFD = qFD = 0.65 at room temperature, a hroad structureless fluorescence spectrum between 400 and 550 nm with a maximum at 470 nm, and no self-absorption in any optical geometry [1]. It would appear to be an ideal crystal fluorescence standard.

Footnotes

*

Paper presented at the Workshop Seminar ‘Standardization in Spectrophotometry and Luminescence Measurements’ held at the National Bureau of Standards, Gaithersburg, Md., Nov. 190–20, 1975.

1

Figures in brackets indicate the literature references at the end of this paper.

5. References

  • 1.Birks JB. Photophysics of Aromatic Molecules. Wiley-Interscience; London, and New York: 1970. [Google Scholar]
  • 2.Birks JB. The Theory and Practice of Scintillation Counting. Pergamon Press; Oxford: 1964. [Google Scholar]
  • 3.Birks JB. Excimers Rpts Prog Phys. 1975;38:903. [Google Scholar]
  • 4.Herzberg G. Molecular Spectra and Molecular Structure I Soectra of Diatomic Molecules. Van Nostrand; Princeton: 1950. [Google Scholar]
  • 5.Birks JB, editor. Excited States of Biological Molecules Proc Intern Conf Lisbon 1974. Wiley-Interscience; London, and New York: 1976. [Google Scholar]
  • 6.Birks JB. In: Organic Molecular Photophysics. Birks JB, editor. II. Wiley-Interscience; London, and New York: 1975. p. 409. [Google Scholar]
  • 7.Tatischeff I., and Klein, R., ref. [5], p. 375 (1976).
  • 8.Birks JB. In: Organic Molecular Photophysics. Birks JB, editor. I. Wiley-Interscience; London, and New York: 1973. p. 1. [Google Scholar]
  • 9.Kasha M. Disc Faraday Soc. 1950;9:14. [Google Scholar]
  • 10.Nickel B. Chem Phys Letters. 1974;27:84. [Google Scholar]
  • 11.Birks JB. Phys Rev. 1954;94:1567. [Google Scholar]
  • 12.Berlman IB. Handbook of Fluorescence Spectra of Aromatic Molecules. 1st edition. 2nd edition. Academic Press; New York: 1965. 1971. [Google Scholar]
  • 13.Lawson CW, Hirayama F, Lipsky S. J Chem Phys. 1969;51:1590. [Google Scholar]
  • 14.Birks JB, Munro IH. Progress in Reaction Kinetics. 1967;4:239. [Google Scholar]
  • 15.Wilkinson F. In: Organic Molecular Photophysics. Birks JB, editor. II. Wiley-Interscience; London, and New York: 1975. p. 95. [Google Scholar]
  • 16.Strickler SJ, Berg RA. J Chem Phys. 1962;37:814. [Google Scholar]
  • 17.Birks JB, Dyson DJ. Proc Roy Soc. 1963;A275:135. [Google Scholar]
  • 18.Ware WR, Baldwin BA. J Chem Phys. 1964;40:1703. [Google Scholar]
  • 19.Cundall RB, Pereira LC. J Chem Soc Faraday Trans II. 1972;68:1152. [Google Scholar]
  • 20.Birks JB, Birch DJS. Chem Phys Letters. 1975;31:608. [Google Scholar]
  • 21.Birch DJS, Birks JB. Chem Phys Letters. in press. [Google Scholar]
  • 22.Birks JB. Z Phys Chem (NF) submitted for publication. [Google Scholar]
  • 23.Birks JB. J Luminescence. 1974;9:311. [Google Scholar]
  • 24.Jablonski A. Nature. 1933;131:839. [Google Scholar]; Z Phys Lpz. 1935;94:38. [Google Scholar]
  • 25.Lewis GN, Kasha M. J Amer Chem Soc. 1944;66:2100. [Google Scholar]
  • 26.Melhuish WH. J Phys Chem. 1960;64:792. [Google Scholar]
  • 27.Lipsett FR. Progress in dielectrics. 1967;7:217. [Google Scholar]
  • 28.Demas JN, Crosby GA. J Phys Chem. 1971;75:991. [Google Scholar]
  • 29.Melhuish WH. J Opt Soc Amer. 1961;51:278. [Google Scholar]
  • 30.Shinitzky M. J Chem Phys. 1972;56:5979. [Google Scholar]
  • 31.Cehelnik ED, Mielenz KD, Velapoldi RA. J Res Nat Bur Stand (US) 1975 Jan-Feb;79A(1):1–15. doi: 10.6028/jres.079A.001. Phys. and Chem. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Mielenz KD, Cehelnik ED, McKenzie RL. J Chem Phys. 1976;64:370. [Google Scholar]
  • 33.Birks JB, Little WA. Proc Phys Soc A. 1953;66:921. [Google Scholar]
  • 34.Birks JB, Christophorou LG. Proc Roy Soc A. 1963;274:552. [Google Scholar]
  • 35.Birks JB. Molec Cryst Liq Cryst. 1975;28:117. [Google Scholar]
  • 36.Melhuish WH. J Phys Chem. 1961;65:229. [Google Scholar]
  • 37.Parker CA. Photoluminescence of Solutions. Elsevier; Amsterdam: 1968. [Google Scholar]
  • 38.Gelernt B, Findeisen A, Stein A, Poole JA. VIII Intern. Conf. Photochemistry; Edmonton. August 1975; Abstract 610. [Google Scholar]

Articles from Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry are provided here courtesy of National Institute of Standards and Technology

RESOURCES