Abstract
Background
The use of radiolabeled choline as a positron emission tomography (PET) agent for imaging primary tumors in the prostate has been evaluated extensively over the past two decades. There are, however, conflicting reports of its sensitivity and the relationship between choline PET imaging and disease staging is not fully understood. Moreover, relatively few studies have investigated the correlation between tracer uptake and histological tumor grade. This work quantified 18F-fluorocholine in tumor and healthy prostate tissue using pharmacokinetic modeling and stratified uptake parameters by histology grade. Additionally, the effect of scan time on the estimation of the kinetic exchange rate constants was evaluated, and the tracer influx parameters from full compartmental analysis were compared to uptake values quantified by Patlak and standardized uptake value (SUV) analyses.
18F-fluorocholine was administered as a 222 MBq bolus injection to ten patients with biopsy-confirmed prostate tumors, and dynamic PET data were acquired for 60 min. Image-derived arterial input functions were scaled by discrete blood samples, and a 2-tissue, 4-parameter model accounting for blood volume (2T4k+Vb) was used to perform fully quantitative compartmental modeling on tumor, healthy prostate, and muscle tissue. Subsequently, all patients underwent radical prostatectomy, and histological analyses were performed on the prostate specimens; kinetic parameters for tumors were stratified by Gleason score. Correlations were investigated between compartmental K 1 and K i parameters and SUV and Patlak slope; the effect of scan time on parameter bias was also evaluated.
Results
Choline activity curves in seven tumors, eight healthy prostate regions, and nine muscle regions were analyzed. Net tracer influx was generally higher in tumor relative to healthy prostate, with the values in the highest grade tumors markedly higher than those in lower grade tumors. Influx terms from Patlak and full compartmental modeling showed good correlation within individual tissue groups. Kinetic parameters calculated from the entire 60-min scan data were accurately reproduced from the first 30 min of acquired data (R 2 ≈ 0.9).
Conclusions
Strong correlations were observed between K i and Patlak slope in tumor tissue, and K 1 and SUV were also correlated but to a lesser degree. Reliable estimates of all kinetic parameters can be achieved from the first 30 min of dynamic 18F-choline data. Although SUV, K 1, K i, and Patlak slope were found to be poor differentiators of low-grade tumor compared to healthy prostate tissue, they are strong indicators of aggressive disease.
Electronic supplementary material
The online version of this article (doi:10.1186/s13550-017-0269-0) contains supplementary material, which is available to authorized users.
Keywords: PET, Choline, Histology, Prostate cancer, Tracer kinetic modeling
Background
Prostate cancer (PCa) is common in the USA and is the second leading cause of cancer death in men. In 2015, 220,800 American men were diagnosed and 27,540 are expected to die from the disease [1]. Despite its prevalence, prognoses are generally good for this disease but accurate diagnoses are critical, as the therapeutic options depend on the aggressiveness and potential progression of the disease.
Clinically, most prostate cancers are detected first by a prostate-specific antigen (PSA) blood test or digital rectal exam and are confirmed through subsequent biopsy. Once confirmed, the patient will undergo diagnostic imaging procedures to assess the spread of the disease and plan treatment. Common imaging modalities include transrectal ultrasound, MRI, and PET/CT. MRI sessions generally consist of T1- and T2-weighted, DWI (diffusion-weighted imaging), and sometimes DCE (dynamic contrast enhanced) and spectroscopy sequences.
Molecular imaging with PET has several benefits due to the ability to target specific underlying biological processes like increased metabolism, upregulated protein and phospholipid synthesis, expression of androgen receptors and membrane proteins, or the osteoblastic reaction adjacent to metastases in the bone marrow [2]. Clinically, routine PET imaging is performed with 18F-fluorodeoxyglucose, but this has shown limited utility for detecting PCa tumors [3, 4]. Improvements in tumor uptake have been reported for other tracers including 11C- and 18F-choline [3, 5–7], 11C-acetate [8–10], 11C-methionine [11, 12], and 18F-fluorodihydrotestosterone [13, 14]. However, these tracers have demonstrated relatively low specificity due to uptake in normal prostate tissue and benign lesions including prostatitis, high-grade intraepithelial neoplasia, or benign prostatic hyperplasia (BPH) [15, 16]. Consequently, recent focus has shifted to monitoring the expression of prostate-specific membrane antigen (PSMA), in which elevated levels have been histologically correlated with PCa tumor progression [17], androgen independence [18], and metastasis [19]. PET agents have been developed as radiolabeled PSMA analogs like 68Ga-PSMA [20, 21] or the PSMA inhibitors 18F-DCFBC [22–24] and 18F-DCFPyL [25]. These new, specific tracers, with high tumor to background contrast, are extremely promising and are being used more frequently, particularly for distant metastases and recurrence. Notwithstanding the growing interest in these novel tracers, 18F-Fluorodexoxyglucose (FDG) and choline are still the most clinically used PET tracers clinically for prostate cancer.
Choline has a strong uptake in the primary prostate tumor, even though it has not been shown to be highly specific, since benign prostatic hyperplasia also shows high uptake. Nevertheless, PET imaging of high choline uptake could be used to guide or support biopsy and surgery of primary prostate cancer. Biopsy procedures, especially of prostate tissue, can cause many issues including patient discomfort and infection. False negative results are also common, which may lead to a repeat biopsy and incorrect diagnosis. Incorporating imaging at an earlier point in the clinical routine can potentially improve patient management.
Radiolabeled choline has been used as a PET agent in humans for 20 years [26], and the prostate was among the first imaging targets [27]. Over the years, many studies have been conducted investigating various aspects of its clinical utility including its efficacy for detecting primary tumors and systemic involvement [28, 29], preoperative staging and pelvic lymphadenopathy [30–32], post-therapy biochemical recurrence and correlations with PSA [33, 34], performance relative to FDG and other PET tracers [3, 35], MRI [36, 37] and MR spectroscopy [38], and quantitative evaluations of tracer kinetics in tissue [39–41]. Choline standardized uptake value (SUV) has been studied extensively, and there are many studies reporting the performance of choline for detecting patients with biopsy-confirmed prostate tumors, though with somewhat controversial results concerning the reported detection sensitivities [16, 42]. However, there are only a limited number of studies which have correlated choline uptake with histological tumor grade, in terms of histologic grading and Gleason score [28, 43, 44]. There are even fewer studies which have modeled the tracer kinetics and investigated those relationships with tissue grade [40] and none to our knowledge using the 18F-labeled derivative.
The aim of this study is to investigate the pharmacokinetics of 18F-fluoromethylcholine in various tissues, including pathology-confirmed primary prostate tumors and healthy prostate tissue, and perform a lesion-based correlation of quantified choline uptake with tumor grade. In particular, compartmental modeling was performed, and tissue parameters were stratified by Gleason score. Additionally, the relationships between tracer perfusion/extraction and influx compartmental rate constants were evaluated between SUV and Patlak linear regression analyses. The effect of scan time on kinetic parameter bias was also assessed.
While the immediate purpose of this work is to investigate the correlation of choline uptake kinetics with histologic tumor grade, it also provides the validation of methods that could be used with other tracers such as PSMA, which may offer an improved approach for characterizing and staging primary prostate cancer.
Methods
Ten men with biopsy-confirmed prostate cancer were recruited for the study. The mean age was 67 years (range, 59–72 years). Blood samples were not collected for one patient (patient 9), and so, he was not included in the kinetic analyses.
The imaging session included a PET/MR scan on the Biograph mMR (Siemens Medical Solutions Inc.). After the imaging session (18.7 ± 12.6 days), each patient underwent a radical prostatectomy and the excised prostate was sliced at 4–5 mm intervals before undergoing tissue processing. At each interval, thin sections of the paraffinized tissue slices were obtained by microtomy and stained for light microscopic assessment.
Image acquisition
For PET/MR, subjects were positioned on the scanning bed, and a 60-min dynamic PET acquisition of the pelvis was started simultaneously with the intravenous injection of 222 MBq 18F-choline. The radiotracer was administered as a 1 mL bolus infused at a rate of 3 mL/s followed by a 20 mL saline flush. Venous blood samples were taken periodically over the course of the PET scan. The nurse’s visits into the scanning room to draw the blood were timed to accommodate the various MR sequences, so as to avoid potential field disturbances during the MR acquisitions. Efforts were made to sample the blood at least every 10 min.
The listmode PET data were divided into 30 frames of 12 × 10, 6 × 30, 5 × 60, 4 × 300, and 3 × 600 s duration, and each frame was reconstructed using an ordinary Poisson ordered subset expectation maximization (OP-OSEM) algorithm, with point spread function (PSF), with 3 iterations and 21 subsets. Attenuation correction was performed on the emission data using a multi-point T1-weighted DIXON sequence to derive the PET 511 keV attenuation map. The final image volume matrices of 172 × 172 × 127, with voxel size of 4.173 × 4.173 × 2.031, were post-smoothed with a 5-mm Gaussian filter.
Arterial input function
The arterial blood signal was extracted from the iliac and femoral vessels in the image frames using factor analysis [45, 46], which involved the calculation of the covariance matrix for all dynamic patient voxels. Eigenanalysis was performed on the covariance matrix and the eigenvectors were ranked according to their corresponding eigenvalues. The eigenvector corresponding to the blood signal was always included as one of the strongest, i.e., having one of the largest eigenvalues, because the initial bolus peak yielded a temporal profile which was uniquely different from the other tissue curves. Factor image volumes were then generated by associating to each voxel, a value representing its contribution to each signal. Figure 1 shows the maximum intensity projections of factor image volumes for one patient. Typically, the strongest three signals comprised the arterial blood, prostate, and bladder activity curves.
The top 40% of the voxels showing the strongest contribution to the arterial signal defined the 3D volume of interest (VOI) over the iliac and femoral arterial structures, and this was projected back on the original image frames to extract the corresponding activity curve. The image-derived blood curve was corrected for partial volume and spillover to produce the actual arterial whole-blood activity A, which was calculated with the following formula:
Here, A 0 is the original, uncorrected arterial blood curve, as measured in the images, and T is the unknown background tissue activity, approximated by a nearby region in muscle. The coefficients a 1 and a 2 correspond to spillover and partial volume, respectively. A least-squares fitting algorithm was employed to find the best estimates of these coefficients, while fitting the extracted blood curve data to the manual blood samples.
Blood-plasma partitioning and metabolite corrections were applied to the whole-blood activity curve to calculate the plasma concentration for the active tracer. As intracellular choline uptake occurs in blood cells, the relative plasma to whole-blood activity ratio changes with time. This general trend was modeled by applying the same plasma-to-whole blood ratio relationship to all patients, starting with 1.3 at injection and decreasing linearly to 1.1 at 60 min (Adriaan Lammertsma, personal communication, July 20, 2016). The plasma fractions were measured in the first four patients, and the approximation was found to be reasonable. In this work, the plasma parent fraction was not measured; the metabolite curve applied to all patients was similar to that found in previous work [47]. An example of the input curve fitting is shown in Fig. 2 for a patient with eight manual blood samples. Additionally, the blood sampling data for the first four patients are included in Additional file 1: Figure S1.
PET analyses and kinetic modeling
Regions of normal and focal tracer uptake were identified in the prostate and normal uptake in muscle tissue, and 30% threshold VOIs were drawn in the last frame of the dynamic series, i.e., images over 50–60 min. This threshold was found to provide acceptable delineation for all tumor foci, and if bladder expansion caused significant movement of the prostate, the VOIs were reregistered in each frame. The tissue time-activity data were weighted by frame length and fit using a 2-tissue model to estimate four compartmental rate parameters and blood volume fraction (V B). For the kinetic modeling and batch analyses, a combination of PMOD Kinetic Modeling Tool version 3.6 (PMOD Technologies Ltd.) and in-house developed software was used.
Selected prostate regions were confirmed histologically as tumor and healthy tissue, and the corresponding perfusion-related parameter K 1 and tracer influx parameter for each, defined as
were correlated with respective 60-min SUV and Patlak analysis collectively for all tissue groups. Additionally, K i was correlated with SUV and Patlak within each tissue group separately.
Histologic correlation
The excised prostate glands were fixed in 4% buffered formalin before undergoing gross dissection. The formalin-fixed prostate specimens were cut into slices of approximately 4 mm thickness, with each slice undergoing tissue processing in its own cassette. After tissue processing, the prostatic tissue was embedded in paraffin in large blocks (megablocks) and sectioned at 3 μm thickness. The sections were mounted on large slides and were stained with hematoxylin and eosin (H&E) before undergoing microscopic evaluation. The tumor tissue was delineated on each slide and assigned modified Gleason grades and an overall Gleason score [48]—this is illustrated in Fig. 3 for a tumor with Gleason score 4 + 3.
The diagnosis of prostatic adenocarcinoma in each case was made by application of well-known microscopic criteria [49]. Prostatic adenocarcinoma can have a variety of microscopic patterns, and these patterns also contribute to the grade of the tumor. In general, prostatic adenocarcinoma tends to consist of malignant acini which are smaller than the adjacent benign acini, and which tend to infiltrate between these benign acini. The malignant acini may also have irregular or elongated contours and may fuse into cribriform structures or solid sheets of cells, among other patterns.
In addition to the routine clinical work-up, the pathologist was asked to follow a sector-based reporting scheme, consistent with the radiologist PI-RADS report. Tumor regions, with their associated Gleason score, were manually delineated within the anatomical map, facilitating the direct coregistration between regions of interest in PET and histopathology; this approach was similar to that used in previous works [40, 43, 44].
Results
Focal 18F-choline uptake was identified in eight prostates, which were confirmed tumors by histology with 3 having Gleason score 3 + 4 (though one of these was from patient 9, without blood sampling, and was omitted from the analyses), 1 with 3 + 5, and 4 with 4 + 3. These and regions of healthy prostate tissue in eight patients were delineated with threshold VOIs. Tumors were not visualized in two patients by PET—histology reports showed the volumes of the largest tumors were less than 0.05 cm3 in both cases. Hence, the uptake trends of the tumors in these patients were not analyzed. For comparison to non-prostatic tissue, muscle activity curves were also measured for all patients.
Overall patterns in tissue uptake were identified. 18F-choline activity curves were relatively high in prostatic tumors, and all curves in tumor tissue either plateaued around 5 min or showed slightly increasing uptake throughout the scan. Uptake also peaked early in healthy prostate tissue, but the curves generally plateaued early or showed slight decrease throughout the scan. This trend was observed in all nine prostates, except for one, which showed only slightly increasing activity. For all measured prostate regions, 18F-choline was rapidly transported from the vascular to intracellular space and metabolized—the majority of the tissue uptake occurred within the first 3 min. Extraction to muscle was also quick, but, in all cases, the tissue activity curves increased continuously throughout the scan. Muscle uptake was much lower than tumor and healthy prostate. All time-activity curves included in the analyses are shown in Fig. 4.
Fully quantitative PET analyses using a 2-tissue compartmental model, accounting for blood volume, were performed on all tissue activity curves over 60 min. The individual values of K 1–k 4 for all tissue regions are given in Table 1. The standard errors on the parameter estimation, derived from the covariance of the model Jacobian at the solution, are also given in the table—they are expressed as the percentage of the corresponding parameter values. The standard error defines the confidence in the estimation precision; a large error may imply that the imposed model is not appropriate for the data. However, even when the errors were high on the individual parameters, the corresponding errors on the net influx macroparameters were generally low because of interparameter correlation. Mean compartmental influx parameters were 0.28 ± 0.21 for the tumors, 0.11 ± 0.04 for the healthy prostates, and 0.04 ± 0.01 for muscle.
Table 1.
Muscle | Healthy prostate | Tumor | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Patient | K 1 | k 2 | k 3 | k 4 | K 1 | k 2 | k 3 | k 4 | K 1 | k 2 | k 3 | k 4 |
1 | 0.04 (21.8%) | 0.05a (>100%) | 1.14a (>100%) | 0a (>100%) | 0.16 (39.2%) | 0.39a (>100%) | 0.66 (80%) | 0.01 (66.5%) | 0.25 (5.5%) | 0.17 (23.3%) | 0.23 (13.7%) | 0.01 (9.8%) |
2 | 0.05 (10.7%) | 0.08a (>100%) | 0.83a (>100%) | 0a (>100%) | 0.32 (6%) | 0.18 (15.5%) | 0.11 (10.7%) | 0.01 (14.7%) | – | – | – | – |
3 | 0.05 (2.4%) | 0.18 (11.2%) | 0.33 (5.5%) | 0 (31.8%) | 0.17 (4%) | 0.05 (13.5%) | 0.02 (50.8%) | 0.01a (>100%) | 0.44 (13.8%) | 0.11 (62.1%) | 0.16 (40.1%) | 0.01 (30.6%) |
4 | 0.05 (4.5%) | 0.16 (21%) | 0.3 (10.3%) | 0a (>100%) | 0.22 (14.5%) | 0.16 (37.7%) | 0.09 (30.5%) | 0.02 (27.3%) | 0.34 (9.8%) | 0.16 (27.1%) | 0.12 (17.3%) | 0 (38.2%) |
5 | 0.05 (23.9%) | 0a (>100%) | 2.7a (>100%) | 0.4a (>100%) | 0.18 (28%) | 0.04a (>100%) | 0.23a (>100%) | 0a (>100%) | – | – | – | – |
6 | 0.04 (61.8%) | 0a (>100%) | 4.9a (>100%) | 1.73a (>100%) | 0.37 (7.4%) | 0.15 (22.4%) | 0.13 (15.7%) | 0.01 (13.7%) | 0.62 (5%) | 0.11 (31.2%) | 0.26 (17.2%) | 0.01 (15.6%) |
7 | 0.07 (4.8%) | 0.11 (38%) | 0.4 (19%) | 0a (>100%) | 0.27 (15.4%) | 0.17 (52%) | 0.18 (30.1%) | 0.01 (25.6%) | 0.29 (2.7%) | 0.19 (8.4%) | 0.18 (4.6%) | 0.01 (6%) |
8 | 0.07 (5%) | 0.13 (39.7%) | 0.42 (22.3%) | 0.02 (16.3%) | – | – | – | – | 1.14 (18.52%) | 0.13 (71.2%) | 0.2 (44.8%) | 0.01 (27.9%) |
10 | 0.1 (15.2%) | 0.25 (35.9%) | 0.16 (18.6%) | 0a (>100%) | 0.13 (17.1%) | 0.11 (72.6%) | 0.16 (45.7%) | 0.01 (38.5%) | 0.38 (6.7%) | 0.2 (16.1%) | 0.11 (10.2%) | 0.01 (21.9%) |
aIndividual parameter estimates were not stable in the cases where the 2T4k+Vb model was not optimal
Patlak analyses were also performed on the same time-activity curves and SUVs recorded. Patlak linear regression fits used the dynamic data after 10 min, and SUV values were calculated by multiplying the tissue activity in the last (50–60-min) frame by the patient weight and dividing by the time-corrected injection activity. Patlak slope and SUV were 0.22 ± 0.15 and 6.6 ± 3.2 for the tumors, 0.09 ± 0.04 and 2.8 ± 0.8 for the healthy prostates, and 0.04 ± 0.01 and 1.2 ± 0.16 for muscle, respectively. The numbers for each patient are given in Table 2.
Table 2.
Healthy prostate | Tumor | ||||||
---|---|---|---|---|---|---|---|
Patient | Tracer flux | Patlak slope | 60-min SUV | Tracer flux | Patlak slope | 60-min SUV | Gleason score |
1 | 0.1 (2.7%) | 0.08 (3.2%) | 2.9 | 0.15 (1.4%) | 0.12 (3.1%) | 4.3 | 3 + 4 |
2 | 0.12 (2.6%) | 0.1 (3.2%) | 2.8 | – | – | – | – |
3 | 0.04 (32.6%) | 0.03 (12.1%) | 1.4 | 0.26 (7.3%) | 0.22 (2.5%) | 7 | 4 + 3 |
4 | 0.08 (8.6%) | 0.05 (5.4%) | 3 | 0.14 (4.3%) | 0.12 (2.6%) | 6.2 | 4 + 3 |
5 | 0.15 (6.5%) | 0.16 (3.9%) | 3.8 | – | – | – | – |
6 | 0.17 (3.7%) | 0.12 (5.6%) | 3.7 | 0.44 (2.6%) | 0.4 (1.5%) | 10.7 | 4 + 3 |
7 | 0.14 (4.5%) | 0.11 (3.7%) | 2.8 | 0.14 (0.7%) | 0.12 (1.6%) | 2.9 | 3 + 5 |
8 | – | – | – | 0.7 (16.5%) | 0.48 (3.4%) | 10.9 | 4 + 3 |
10 | 0.08 (4.9%) | 0.06 (3.4%) | 2.3 | 0.14 (2.8%) | 0.12 (1.7%) | 4.2 | 3 + 4 |
The tumor data in this table is represented graphically in Fig. 5, where the three key numerical parameters, K 1, Patlak slope, and SUV, are plotted as a function of Gleason score.
The correlations between SUV and Patlak analysis and compartmental tracer kinetic modeling were evaluated, using K 1 and macroinflux parameter K i as figures of merit. Correlation of the simplified methods with K i was better than that with K 1, shown in Fig. 6. The regression fit is displayed on each respective plot, along with the coefficient of determination and p value. Significance was calculated using a one-tailed F test against the null hypothesis of no correlation.
The good correlation observed was largely attributed to the relatively large intertissue range of values used for the regression fit, especially for SUV. Hence, the correlations were generally poorer within individual tissue groups. Patlak influx, however, still performed relatively well with respect to kinetic influx parameter K i, as seen in Fig. 7.
The effect of scan time on the estimation of the compartmental rate parameters was investigated. The absolute bias on the estimates of K 1–k 4 and K i for all tissue regions, relative to those at 60 min, is shown in Fig. 8.
Relative bias on the k 2–k 4 parameter estimates was observed for the shorter scan times, but K 1 and K i showed more stability, with mean biases at 3.6 and 7.4% and 12.1 and 44.2% at 30- and 10-min scan times, respectively. The relationship between the K i flux values from the 60-min scan and those calculated using only the first 30 and 10 min of dynamic data was investigated, and the correlation for each tissue group is shown in Fig. 9.
For all tissue groups, the data showed that choline influx parameters, calculated with 30 min of dynamic data, were significantly well correlated with those of the full 60 min.
Discussion
This work investigated 18F-choline uptake patterns in prostatic tumors, healthy prostate tissue, and muscle; tracer kinetic analyses were performed with compartmental modeling. Plasma input functions were obtained through image-derived methods, fit to manual blood measurements while accounting for partial volume and spillover effects, and corrected for plasma partitioning and metabolites. Correlations were evaluated between the influx rate parameter calculated from fully quantitative analyses and Patlak and 60-min SUV.
A limitation of this study is that arterial blood was not collected from the subjects, so accurate measurements of the radiolabeled metabolites were not possible. Hence, we applied a single metabolite correction to all plasma curves. This method, however, is not ideal, since high interpatient variability in the parent tracer fraction has been reported [41] which could lead to errors and bias in the estimations of the rate parameters. To characterize these effects, we systematically ran the curve fitting algorithm on all tissue data with different metabolite corrections [41, 47, 50] and corresponding plasma inputs. We found that there were indeed rather large variances on some of the estimations of the individual microparameters K 1–k 4, but that the calculations of the macroflux parameter K i were robust. A similar investigation was performed to assess the effect of the plasma partitioning. For the first four patients with manual blood sampling, the kinetic parameters estimated using the linear partitioning method used here were compared to those estimated using the mean of the individual patient measurements as a constant partitioning ratio. Again, we found that the estimates of the individual compartmental rate parameters were far more sensitive to this than the calculated tracer influx. Plots showing the results of both of these tests are shown in Additional file 1: Figures S2 and S3.
Regarding the choice of compartment model, we ran the curve fitting algorithm on all tissue data using four different models: 1T1k+Vb, 1T2k+Vb, 2T3k+Vb, and 2T4k+Vb. The most appropriate compartmental model to characterize choline kinetics was chosen based on the mean value of the Akaike information criterion (AIC) [51] calculated for all tissue curves (Additional file 1: Figure S4), and this was found to be the 2T4k+VB compartmental model. However, the Akaike weight was only just the lowest with this model—in fact, half of the tissue curves preferred the 2T3k+Vb model, and different choices of input model may have led to small differences in this result. The use of a reversible model is not consistent with previous works which have reported irreversible tracer kinetics in tissue—indeed, the k 4 values were found to be very small compared to the other parameters. So, even though the AIC analyses suggested a model which did not constrain k 4 to be zero, the net influx rates were still well correlated with those of Patlak analyses. The 2T4k+VB model performed well overall, but in some cases, it rendered the fitting algorithm unable to find the global minimum, especially in the muscle regions where the slow monotonically increasing uptake was better represented by an irreversible model. Fitting the data to a model with too many parameters produced unstable estimates on parameter values, as seen in Table 1. This is consistent with previous work which reported that the 2T3k+Vb model provided the lowest AIC, but a 1T1k+Vb compartmental model may be best to quantify 18F-fluoromethylcholine due to its robustness [41]. We were however unable to achieve reliable fits for all tissue data with this model, as illustrated in Fig. 10. This is probably due to the different regions investigated, since we found that different tissues may require different models, even within the same subject.
The parameters that were evaluated to characterize choline uptake in tissue were SUV, K 1, K i, and Patlak slope. The most relevant result of this study is that SUV, K 1, K i, and Patlak slope are indeed strong indicators of aggressive tumor in the prostate. As can be seen in Fig. 5, while all three parameters show limited correlation with Gleason score for low-grade tumors, they all show a dramatic increase at Gleason score 4 + 3. This could suggest that SUV, and even better K i and Patlak slope, could be used as indicators of aggressive tumors. Microparameters k 2, k 3, and k 4 showed no correlation with Gleason score (results not reported). However, it is possible that these kinetic parameters could be more helpful in PET imaging with tracers other than choline.
It is well known that choline is rapidly transported and phosphorylated within the cells [39], and indeed, we observed that the majority of the tissue tracer uptake occurred within the first 5–10 min. Hence, this work investigated the effects of scan time reduction on the quantitative analyses. Here, we found that the calculation variability in the microparameters k 2–k 4 was sensitive to the scan time but estimates of perfusion and choline transport, represented by K 1, and the macroflux parameter K i were more stable; this finding is not uncommon for compartmental modeling tasks. This notwithstanding, accurate characterizations of 18F-choline influx for all tissue could be quantified using 30 min of dynamic scan data, as can be appreciated in Figs. 8 and 9. Further, the K i correlations we found were comparable to those reported by Verwer et al. for scan durations 40 vs. 10 min, 40 vs. 20 min, and 40 vs. 30 min. Our correlation slopes for the same times were 1.2, 1.1, and 0.99 and those from Verwer et al. were 0.93, 1.05, and 1.03. Our R 2 values were 0.93, 0.95, and 1, and those from Verwer et al. were 0.97, 0.9, and 1. These findings may prove useful for future studies investigating dynamic 18F-choline PET for prostate applications, since scan time should be kept to a minimum for patient convenience and scanner throughput considerations and also to avoid bladder filling issues (which is not a consideration for the 11C-labeled derivative). Motion is not typically a major problem with pelvic scanning, but expansion of the bladder can cause deformation of the internal structures, affecting the voxel measurements over time. Shorter scan times would minimize these effects.
An important result of this work is the development of a method and a protocol to perform kinetic studies of prostate cancer tracer in primary tumor and perform correlation between compartmental model parameters and Gleason score. We plan to apply these methods with other newer and more specific tracers for prostate cancer, with the purpose of correlating aggressiveness of the disease and PET imaging parameters, therefore providing a non-invasive method for supporting staging and therapy planning of primary tumor.
Conclusions
This study of the kinetics of 18F-choline, using both Patlak method and fully compartmental modeling, showed a strong correlation between K i and Patlak slope in tumor tissue; K 1 and SUV were also correlated to a lesser degree. Due to differences in 18F-choline uptake profiles for different tissues, a 2-tissue model was needed to quantify tracer uptake. Fully quantitative analyses were performed for accurate characterization of the tissue uptake, but this work showed that reliable estimates of all kinetic parameters can be achieved with only 30 min of dynamic data. Finally, an interesting result of this study is that even if SUV, K 1, K i, and Patlak slope are poor differentiators of low-grade tumor compared to healthy prostate tissue, they are strong indicators of aggressive disease: they all dramatically increase at Gleason score 4 + 3. The good correlation between K i as determined from the compartment model and from the Patlak analyses indicates that the Patlak plot can be used as a substitute for full compartmental analysis of the 18F-choline data in the prostate.
Acknowledgments
Funding
This study was funded by the National University Cancer Institute, Singapore Centre Grant Seed Funding Program
Authors’ contributions
JS analyzed the PET data and wrote the manuscript. ZW and MS assisted with the imaging protocol. SR facilitated the correlation of the imaging and histologic registration. MC was integral in developing the study concept and reviewed the manuscript. LE assisted with the analyses and reviewed the manuscript. DT gave advice in the data interpretation and reviewed the manuscript. TT performed the histologic analyses. EC recruited the patients and reviewed the manuscript. All authors read and approved the final manuscript.
Competing interests
The authors declare that they have no competing interests.
Ethics approval and consent to participate
This study was approved by the Domain Specific Review Board (DSRB) of the National University Hospital Singapore, and all the subjects signed an informed consent to participate.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abbreviations
- 2T4k+Vb
Compartmental model using 2-tissues and 4 rate + blood volume parameters
- AIC
Akaike information criterion
- BPH
Benign prostatic hyperplasia
- DCE
Dynamic contrast enhanced
- DSRB
Domain specific review board
- DWI
Diffusion-weighted imaging
- FDG
18F-Fluorodeoxyglucose
- H&E
Hematoxylin and eosin
- OP-OSEM
Ordinary Poisson ordered subset expectation maximization
- PCa
Prostate cancer
- PET
Positron emission tomography
- PSA
Prostate-specific antigen
- PSF
Point spread function
- PSMA
Prostate-specific membrane antigen
- SUV
Standardized uptake value
- VB
Blood volume fraction
- VOI
Volume of interest
Additional file
Footnotes
Electronic supplementary material
The online version of this article (doi:10.1186/s13550-017-0269-0) contains supplementary material, which is available to authorized users.
An erratum to this article is available at https://doi.org/10.1186/s13550-017-0299-7.
References
- 1.Siegel RL, Miller KD, Jemal A. Cancer statistics, 2015. CA Cancer J Clin. 2015;65:5–29. doi: 10.3322/caac.21254. [DOI] [PubMed] [Google Scholar]
- 2.Wibmer AG, Burger IA, Sala E, Hricak H, Weber WA, Vargas HA. Molecular imaging of prostate cancer. Radio Graphics. 2015;36:142–59. doi: 10.1148/rg.2016150059. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Price DT, Coleman RE, Liao RP, Robertson CN, Polascik TJ, Degrado TR. Comparison of [18F] fluorocholine and [18F] fluorodeoxyglucose for positron emission tomography of androgen dependent and androgen independent prostate cancer. J Urol. 2002;168:273–80. doi: 10.1016/S0022-5347(05)64906-3. [DOI] [PubMed] [Google Scholar]
- 4.Oehr P, Bouchelouche K. Imaging of prostate cancer. Curr Opin Oncol. 2007;19:259–64. doi: 10.1097/CCO.0b013e3280ad439b. [DOI] [PubMed] [Google Scholar]
- 5.Apolo AB, Pandit-Taskar N, Morris MJ. Novel tracers and their development for the imaging of metastatic prostate cancer. J Nucl Med. 2008;49:2031–41. doi: 10.2967/jnumed.108.050658. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Jadvar H. Prostate cancer: PET with 18F-FDG, 18F-or 11C-acetate, and 18F-or 11C-choline. J Nucl Med. 2011;52:81–9. doi: 10.2967/jnumed.110.077941. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Bauman G, Belhocine T, Kovacs M, Ward A, Beheshti M, Rachinsky I. 18F-fluorocholine for prostate cancer imaging: a systematic review of the literature. Prostate Cancer Prostatic Dis. 2012;15:45–55. doi: 10.1038/pcan.2011.35. [DOI] [PubMed] [Google Scholar]
- 8.Oyama N, Akino H, Kanamaru H, et al. 11C-acetate PET imaging of prostate cancer. J Nucl Med. 2002;43:181–6. [PubMed] [Google Scholar]
- 9.Dimitrakopoulou-Strauss A, Strauss LG. PET imaging of prostate cancer with 11C-acetate. J Nucl Med. 2003;44:556–8. [PubMed] [Google Scholar]
- 10.Schiepers C, Hoh CK, Nuyts J, et al. 1-11C-acetate kinetics of prostate cancer. J Nucl Med. 2008;49:206–15. doi: 10.2967/jnumed.107.044453. [DOI] [PubMed] [Google Scholar]
- 11.Nilsson S, Kalkner M, Ginman C, et al. 11C-methionine positron emission tomography in the management of prostatic carcinoma. Antib Immunoconjug Radiopharm. 1995;8:23. [Google Scholar]
- 12.Macapinlac HA, Humm JL, Akhurst T, et al. Differential metabolism and pharmacokinetics of L-[1-11C]-methionine and 2-[18F] fluoro-2-deoxy-D-glucose (FDG) in androgen independent prostate cancer. Clin Positron Imag. 1999;2:173–81. doi: 10.1016/S1095-0397(99)00015-1. [DOI] [PubMed] [Google Scholar]
- 13.Bonasera TA, O’Neil JP, Xu M, et al. Preclinical evaluation of fluorine-18-labeled androgen receptor ligands in baboons. J Nucl Med. 1996;37:1009–15. [PubMed] [Google Scholar]
- 14.Larson SM, Morris M, Gunther I, et al. Tumor localization of 16β-18F-fluoro-5α-dihydrotestosterone versus 18F-FDG in patients with progressive, metastatic prostate cancer. J Nucl Med. 2004;45:366–73. [PubMed] [Google Scholar]
- 15.Kato T, Tsukamoto E, Kuge Y, et al. Accumulation of [11C] acetate in normal prostate and benign prostatic hyperplasia: comparison with prostate cancer. Eur J Nucl Med Mol Imaging. 2002;29:1492–5. doi: 10.1007/s00259-002-0885-3. [DOI] [PubMed] [Google Scholar]
- 16.Schwarzenböck S, Souvatzoglou M, Krause B. Choline PET and PET/CT in primary diagnosis and staging of prostate cancer. Theranostics. 2012;2:318. doi: 10.7150/thno.4008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Perner S, Hofer MD, Kim R, et al. Prostate-specific membrane antigen expression as a predictor of prostate cancer progression. Hum Pathol. 2007;38:696–701. doi: 10.1016/j.humpath.2006.11.012. [DOI] [PubMed] [Google Scholar]
- 18.Wright GL, Grob BM, Haley C, et al. Upregulation of prostate-specific membrane antigen after androgen-deprivation therapy. Urology. 1996;48:326–34. doi: 10.1016/S0090-4295(96)00184-7. [DOI] [PubMed] [Google Scholar]
- 19.Chang SS, Reuter VE, Heston W, Gaudin PB. Metastatic renal cell carcinoma neovasculature expresses prostate-specific membrane antigen. Urology. 2001;57:801–5. doi: 10.1016/S0090-4295(00)01094-3. [DOI] [PubMed] [Google Scholar]
- 20.Eder M, Schäfer M, Bauder-Wüst U, et al. 68Ga-complex lipophilicity and the targeting property of a urea-based PSMA inhibitor for PET imaging. Bioconjug Chem. 2012;23:688–97. doi: 10.1021/bc200279b. [DOI] [PubMed] [Google Scholar]
- 21.Afshar-Oromieh A, Malcher A, Eder M, et al. PET imaging with a [68Ga] gallium-labelled PSMA ligand for the diagnosis of prostate cancer: biodistribution in humans and first evaluation of tumour lesions. Eur J Nucl Med Mol Imaging. 2013;40:486–95. doi: 10.1007/s00259-012-2298-2. [DOI] [PubMed] [Google Scholar]
- 22.Mease RC, Dusich CL, Foss CA, et al. N-[N-[(S)-1,3-Dicarboxypropyl]carbamoyl]-4-[18F]fluorobenzyl-L-cysteine, [18F] DCFBC: a new imaging probe for prostate cancer. Clin Cancer Res. 2008;14:3036–43. doi: 10.1158/1078-0432.CCR-07-1517. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Cho SY, Gage KL, Mease RC, et al. Biodistribution, tumor detection, and radiation dosimetry of 18F-DCFBC, a low-molecular-weight inhibitor of prostate-specific membrane antigen, in patients with metastatic prostate cancer. J Nucl Med. 2012;53:1883–91. doi: 10.2967/jnumed.112.104661. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Rowe SP, Gage KL, Faraj SF, et al. 18F-DCFBC PET/CT for PSMA-based detection and characterization of primary prostate cancer. J Nucl Med. 2015;56:1003–10. doi: 10.2967/jnumed.115.154336. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Szabo Z, Mena E, Rowe SP, et al. Initial evaluation of [18F] DCFPyL for prostate-specific membrane antigen (PSMA)-targeted PET imaging of prostate cancer. Mol Imaging Biol. 2015;17:565–74. doi: 10.1007/s11307-015-0850-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Hara T, Kosaka N, Shinoura N, Kondo T. PET imaging of brain tumor with (methyl-11C) choline. J Nucl Med. 1997;38:842. [PubMed] [Google Scholar]
- 27.Hara T, Kosaka N, Kishi H. PET imaging of prostate cancer using carbon-11-choline. J Nucl Med. 1998;39:990. [PubMed] [Google Scholar]
- 28.Reske SN, Blumstein NM, Neumaier B, et al. Imaging prostate cancer with 11C-choline PET/CT. J Nucl Med. 2006;47:1249–54. [PubMed] [Google Scholar]
- 29.Scher B, Seitz M, Albinger W, et al. Value of 11C-choline PET and PET/CT in patients with suspected prostate cancer. Eur J Nucl Med Mol Imaging. 2007;34:45–53. doi: 10.1007/s00259-006-0190-7. [DOI] [PubMed] [Google Scholar]
- 30.De Jong IJ, Pruim J, Elsinga PH, Vaalburg W, Mensink HJ. Preoperative staging of pelvic lymph nodes in prostate cancer by 11C-choline PET. J Nucl Med. 2003;44:331–5. [PubMed] [Google Scholar]
- 31.Scattoni V, Picchio M, Suardi N, et al. Detection of lymph-node metastases with integrated [11C] choline PET/CT in patients with PSA failure after radical retropubic prostatectomy: results confirmed by open pelvic-retroperitoneal lymphadenectomy. Eur Urol. 2007;52:423–9. doi: 10.1016/j.eururo.2007.03.032. [DOI] [PubMed] [Google Scholar]
- 32.Husarik DB, Miralbell R, Dubs M, et al. Evaluation of [18F]-choline PET/CT for staging and restaging of prostate cancer. Eur J Nucl Med Mol Imaging. 2008;35:253–63. doi: 10.1007/s00259-007-0552-9. [DOI] [PubMed] [Google Scholar]
- 33.Krause B, Souvatzoglou M, Tuncel M, et al. The detection rate of [11C] choline-PET/CT depends on the serum PSA-value in patients with biochemical recurrence of prostate cancer. Eur J Nucl Med Mol Imaging. 2008;35:18–23. doi: 10.1007/s00259-007-0581-4. [DOI] [PubMed] [Google Scholar]
- 34.Castellucci P, Fuccio C, Nanni C, et al. Influence of trigger PSA and PSA kinetics on 11C-choline PET/CT detection rate in patients with biochemical relapse after radical prostatectomy. J Nucl Med. 2009;50:1394–400. doi: 10.2967/jnumed.108.061507. [DOI] [PubMed] [Google Scholar]
- 35.Brogsitter C, Zöphel K, Kotzerke J. 18F-Choline, 11C-choline and 11C-acetate PET/CT: comparative analysis for imaging prostate cancer patients. Eur J Nucl Med Mol Imaging. 2013;40:18–27. doi: 10.1007/s00259-013-2358-2. [DOI] [PubMed] [Google Scholar]
- 36.Eschmann S, Schlemmer H, Pfannenberg A, et al. Comparison of 11C-choline-PET/CT and whole body-MRI for staging of prostate cancer. J Nucl Med. 2006;47:181P. doi: 10.1160/nukmed-0075. [DOI] [PubMed] [Google Scholar]
- 37.Beer AJ, Eiber M, Souvatzoglou M, et al. Restricted water diffusibility as measured by diffusion-weighted MR imaging and choline uptake in 11C-choline PET/CT are correlated in pelvic lymph nodes in patients with prostate cancer. Mol Imaging Biol. 2011;13:352–61. doi: 10.1007/s11307-010-0337-6. [DOI] [PubMed] [Google Scholar]
- 38.Yamaguchi T, Lee J, Uemura H, et al. Prostate cancer: a comparative study of 11C-choline PET and MR imaging combined with proton MR spectroscopy. Eur J Nucl Med Mol Imaging. 2005;32:742–8. doi: 10.1007/s00259-004-1755-y. [DOI] [PubMed] [Google Scholar]
- 39.DeGrado TR, Reiman RE, Price DT, Wang S, Coleman RE. Pharmacokinetics and radiation dosimetry of 18F-fluorocholine. J Nucl Med. 2002;43:92–6. [PubMed] [Google Scholar]
- 40.Sutinen E, Nurmi M, Roivainen A, et al. Kinetics of [11C] choline uptake in prostate cancer: a PET study. Eur J Nucl Med Mol Imaging. 2004;31:317–24. doi: 10.1007/s00259-003-1377-9. [DOI] [PubMed] [Google Scholar]
- 41.Verwer EE, Oprea-Lager DE, van den Eertwegh AJ, et al. Quantification of 18F-fluorocholine kinetics in patients with prostate cancer. J Nucl Med. 2015;56:365–71. doi: 10.2967/jnumed.114.148007. [DOI] [PubMed] [Google Scholar]
- 42.Souvatzoglou M, Gaertner FC, Schwarzenboeck S, Beer AJ, Schwaiger M, Krause BJ. PET/CT for the diagnosis, staging and restaging of prostate cancer. Imaging in Medicine. 2011;3:571–85. doi: 10.2217/iim.11.48. [DOI] [Google Scholar]
- 43.Farsad M, Schiavina R, Castellucci P, et al. Detection and localization of prostate cancer: correlation of 11C-choline PET/CT with histopathologic step-section analysis. J Nucl Med. 2005;46:1642–9. [PubMed] [Google Scholar]
- 44.Kwee SA, Coel MN, Lim J, Ko JP. Prostate cancer localization with 18 fluorine fluorocholine positron emission tomography. J Urol. 2005;173:252–5. doi: 10.1097/01.ju.0000142099.80156.85. [DOI] [PubMed] [Google Scholar]
- 45.Wu H-M, Hoh CK, Choi Y, et al. Factor analysis for extraction of blood time-activity curves in dynamic FDG-PET studies. J Nucl Med. 1995;36:1714–22. [PubMed] [Google Scholar]
- 46.Schiepers C, Hoh CK, Nuyts J, Wu HM, Phelps ME, Dahlbom M. Factor analysis in prostate cancer: delineation of organ structures and automatic generation of in-and output functions. Nucl Sci IEEE Trans. 2002;49:2338–43. doi: 10.1109/TNS.2002.803872. [DOI] [Google Scholar]
- 47.Roivainen A, Forsback S, Grönroos T, et al. Blood metabolism of [methyl-11C] choline; implications for in vivo imaging with positron emission tomography. Eur J Nucl Med. 2000;27:25–32. doi: 10.1007/PL00006658. [DOI] [PubMed] [Google Scholar]
- 48.Epstein JI, Allsbrook WC, Jr, Amin MB, Egevad LL, Committee IG. The 2005 International Society of Urological Pathology (ISUP) consensus conference on Gleason grading of prostatic carcinoma. Am J Surg Pathol. 2005;29:1228–42. doi: 10.1097/01.pas.0000173646.99337.b1. [DOI] [PubMed] [Google Scholar]
- 49.Bostwick DG, Cheng L. Urologic surgical pathology. Elsevier Health Sciences; 2008.
- 50.Slaets D, De Vos F. Comparison between kinetic modelling and graphical analysis for the quantification of [18F] fluoromethylcholine uptake in mice. EJNMMI Res. 2013;3:66. doi: 10.1186/2191-219X-3-66. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Glatting G, Kletting P, Reske SN, Hohl K, Ring C. Choosing the optimal fit function: comparison of the Akaike information criterion and the F-test. Med Phys. 2007;34:4285–92. doi: 10.1118/1.2794176. [DOI] [PubMed] [Google Scholar]