Abstract
A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces.
Introduction
Cobalt–chromium (CoCr) and nickel–chromium (NiCr) alloys are widely used in dental prostheses such as metal plates for complete dentures and frameworks for partial dentures, crowns, and bridges [1]. It is very important to study the corrosion characteristics of dental metals and alloys because their corrosion in the oral environment may adversely affect material biocompatibility and mechanical integrity, and lead to aesthetic loss of dental restorations, health hazards, and physical weakness. Serious concerns about the biocompatibility of dental alloys, related to the corrosion-induced metal ion release process, have been expressed [2]. Therefore, the investigation of the corrosion behavior of CoCr and NiCr alloys is essential for better understanding of their biocompatibility properties [3, 4].
The corrosion resistance of an alloy depends not only on its material properties, but also on its interactions with the surroundings [5]. The corrosion behavior of dental alloys can be affected by the oral environment (which may contain saliva, dental plaque, bacteria, and gastric acid reflux) as well as by the acidity and oxygen levels. The oral environment is warm and humid and continually experiences temperature fluctuations, while the moderate pH and temperature levels together with the abundance of nutrients create the ideal conditions for microorganism growth and development [6–8]. Microbiology-related corrosion (observed in the medical industry for many years) is defined as the deterioration of the metal surface due to the direct or indirect activity of living microorganisms. However, the exact mechanism describing the effect produced by the presence of bacteria and their byproducts on the corrosion behavior of metallic dental materials is currently unknown [9].
It has been previously shown that the microbial metabolic activities in complex biological systems can affect the pitting corrosion behavior of stainless steels [10]. Owing to the biofilm formation on metal surfaces and related effects, elucidating the interactions between dental materials and various bacterial species is very important for improving their corrosion properties.
The presence of Desulfotomaculum nigrificans sulfate reducing bacteria (SRB) was found to significantly affect the corrosion behaviour of Co-Cr-Mo and Ti-6Al-4V alloys [11], while Streptococcus mutans (S. mutans) and Streptococcus sanguinis species (which easily created biofilms on teeth surfaces) were able to corrode various orthodontic SUS appliances [12].
The mechanisms of microbially induced corrosion and the related corrosion inhibition process have not been elucidated in sufficient detail because of the inability to link them to a single biochemical reaction or specific microbial species or groups [13]. Thus, S. mutans bacteria were selected for investigation in this study because of their extensive presence in the oral environment of almost all people. In addition, S. mutans species grown under standard conditions are characterized by the abilities to produce a distinctive colonial morphology in any sucrose-containing medium (such as mitis salivarius agar), synthesize extracellular polysaccharides from sucrose, and undergo cell-to-cell aggregation when mixed with sucrose or dextran. These unique features of S. mutans may enhance its colonization activity in the oral cavity [9,14].
The purpose of this study was to investigate the early-stage microbiology-related corrosion behavior of NiCr and CoCr alloys in the presence of S. mutans by various electrochemical methods. The novelty of the conducted research is represented by the observed effect of the oral biofilms composed of S. mutans on the simultaneous corrosion behavior of the studied alloys in artificial saliva.
Materials and methods
Materials
Sample preparation
CoCr and NiCr alloys were acquired from Dental Alloys USA Inc. and Kennametal Stellite, respectively. Their compositions (listed in Table 1) were provided by the manufacturers.
Table 1. Chemical compositions of the utilized dental alloys (wt.%).
Alloy | Ni | Co | Cr | Mo | Mn+Si+Fe | Other |
---|---|---|---|---|---|---|
NiCr (Kennametal Stellite, CHINA) | 64 | – | 22.5 | 9.5 | – | <4 |
CoCr (Dental Alloys, USA) | – | 61 | 28 | 5 | 3 | <3 |
Sheet-like material samples with dimensions of 10 mm × 10 mm × 2 mm were prepared in accordance with the manufacturers’ recommendations using a laboratory lost wax technique [15]. Before corrosion testing, all samples were ground with 180-, 320-, and 600-grit Si carbide abrasive papers and then polished with 9-, 3-, and 0.05-μm diamond suspensions (Buehler, Germany) to produce mirror-like surfaces. A brass wire was welded to the specimen’s back side. The back and sides of each sample were embedded in a piece of epoxy resin with an area of 1 cm2, leaving the polished surface exposed. Each sample was cleaned ultrasonically in distilled water and ethanol for 2 min. To remove possible contaminations, the prepared test samples were exposed to ultraviolet light for 1 h.
Growth of Streptococcus mutans species
The microorganisms used in this study were S. mutans (UA159). Their primary colonizer was taken directly from an experimental room. S. mutans species were resuscitated from a frozen stock culture and incubated on plates at 37°C for 20–24 h in an atmosphere consisting of 5% CO2 and 95% N2 gases. Gram stain and colony morphology studies were conducted to confirm the purity of the grown S. mutans bacteria, which were collected from the incubating plates and placed in the tryptic soy broth (TSB) solution with the composition listed in Table 2. This solution had been previously sterilized in an autoclave (ES-315, TOMY, Japan) for 20 min at a temperature of 121°C and pressure of 15 psi.
Table 2. A composition of the TSB (g/L) solution utilized in this study.
Substance | Weight |
---|---|
Pancreatic digest of casein (tryptone) | 17.0 |
Papaic digest of soy meat (polypeptone) | 3.0 |
Sodium chloride (NaCl) | 5.0 |
Dipotassium phosphate (K2HPO4) | 2.5 |
Yeast extract powder | 1.0 |
Dextrose | 2.5 |
Electrolyte preparation
The composition of the artificial saliva (AS) solution utilized in this work is summarized in Table 3. To reduce contamination during preparation, the AS was sterilized by autoclaving for 20 min at a temperature of 121°C and pressure of 15 psi. Solution 1 was prepared from the mixture of the sterilized AS and TSB solutions with the AS:TSB volume ratio of 10:1, while Solution 2 was obtained from the sterilized AS mixed with S. mutans species at a volume ratio of 10:1. The S. mutans concentration of 108 CFU/mL corresponded to the absorbance intensity of 1.0 obtained at a wavelength of 540 nm. Before electrochemical measurements the samples were immersed in Solution 1 or 2 for 24 h.
Table 3. A composition of the AS (g/L) solution obtained at pH = 6.8.
KCl | NaCl | MgCl2.6H2O | CaCl2.2H2O | Polypeptone | NaF | KH2PO4 | K2HPO4 |
---|---|---|---|---|---|---|---|
1.3 | 0.1 | 0.05 | 0.1 | 0.5 | 0.000025 | 0.027 | 0.035 |
Methods
Electrochemical studies
A three-electrode electrochemical cell was utilized in all experiments. A saturated Ag/AgCl electrode was used as the reference electrode, a Pt electrode was used as the counter electrode, and the alloy samples were utilized as the working electrodes. Electrochemical measurements were conducted at a constant temperature of 37°C using a Princeton Applied Research electrochemical station (Parstat 2273, Ametek, Princeton, USA) controlled by a personal computer equipped with the PowerSuite software (Ametek, Princeton Applied Research). The samples treated with Solutions 1 and 2 were studied by conducting open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization measurements. Corrosion parameters including OCPs, corrosion current densities (icorr), and charge transfer resistance values (Rct) obtained from the electrochemical measurements were used to evaluate the corrosion resistance of the studied alloys. Three specimens were utilized during each corrosion testing procedure.
OCPs were measured within 1 h after the sample immersion in the electrolyte solution (the related potential–time curves were recorded at 2-s intervals). EIS measurements were performed in the frequency range between 105 Hz and 10−2 Hz at an applied voltage amplitude of 10 mV after the OCP studies. Rct values were determined from the equivalent circuits estimated by analyzing the plots obtained with the ZSimpWin software (Princeton Applied Research). Potentiodynamic polarization curves were recorded in the the scan range between -500 mV and +1600 mV (vs OCP) at a scanning rate of 1 mV/s [16]. Icorr values were determined using the curve-fitting routine of the PowerSuite software. All potentials in this study are reported with respect to the saturated Ag/AgCl electrode.
Surface analysis
To confirm the presence of bacteria on the metal surface and investigate the effect of the surface morphology on the alloy properties, the dental alloy samples treated with Solution 2 for 24 h were studied by scanning electron microscopy (SEM; JEOL JSM 6400, Tokyo, Japan). After incubation of S. mutans cells at 37°C for 24 h in microplate wells, a biofilm was formed on the sample surface. The specimens were first fixed with a 2.5% glutaraldehyde solution in phosphate buffer (pH = 7.0) for more than 4 h, washed three times in the phosphate buffer, post-fixed with a 1% OsO4 solution in phosphate buffer (pH = 7.0) for 1 h, and washed again three times in the phosphate buffer. Afterwards, the specimens were dehydrated with graded ethanol solutions, critical-point dried, coated with a Pd–Pt layer, and examined by SEM.
Statistical analysis
All corrosion tests were repeated until at least three similar results were obtained. The one-way analysis of variance (ANOVA) technique with a statistical significance level set to p = 0.05 was used (SPSS software, v11.5, USA).
Results
OCP measurements
The OCP values obtained for CoCr and NiCr alloys treated in both solutions at 37°C are plotted as functions of the immersion time in Fig 1. The OCPs of CoCr alloy treated with Solutions 1 and 2 for 1 h were stabilized at levels of -0.175 V and -0.237 V (vs. Ag/AgCl) respectively. Similarly, the OCPs of NiCr alloy were stabilized after 1 h of treatment with Solutions 1 and 2 at magnitudes of –0.244 V and –0.274 V (vs. Ag/AgCl), respectively. Hence, the OCPs of both alloys decreased after their treatment with the AS containing S. mutans species (the observed potential drops were 0.04 V (vs. Ag/AgCl) for CoCr alloy and 0.03 V (vs. Ag/AgCl) for NiCr alloy.Laurent et al [16] reported similar results for the OCP of a non-precious alloy immersed in AS solution.
EIS measurements
Fig 2 shows the EIS data obtained for the alloy samples immersed in Solutions 1 and 2 for 24 h. The Nyquist diagram (Fig 2a) displays a single capacitive arc in the complex plane with a diameter increasing in the presence of S. mutans (higher arc radii generally result in higher magnitudes of Rct). The Bode diagram (Fig 2b) shows that all of the treated samples exhibited high impedance corresponding to capacitive behavior. The phase angle in the 10−2–102 Hz frequency range was close to 80°, and the phase change at higher frequencies was approximately 0°, indicating that the main resistance was ohmic (similar results were reported by Liu et al. [17]). All samples were in the passive state after the exposure to the simulated oral environment. Only one time constant was measured for the dental alloy samples that were not exposed to S. mutans, whereas two different time constants were obtained for the samples exposed to Solution 2 (their values were estimated by fitting the corresponding Bode diagram).
It is typically difficult to design new equivalent circuits for complex systems such as the electrodes partially covered with biofilms. The EIS results obtained in this study were fitted with well-known equivalent circuits [18] using the ZSimpWin software (see Fig 3). The R(QR) circuit (Fig 3a) was used to fit the data obtained for the samples immersed in the sterile medium, and the R(Q(R(QR))) circuit (Fig 3b) was used to fit the data obtained for the alloys exposed to S. mutans species [19]. Q is a constant-phase element (CPE) that represented a shift from the ideal capacitor and was utilized instead of the capacitance to take into account the real capacitive behavior of the film. By using the R(QR) element, it was assumed that the oxide layer consisted of a compact layer with polarization resistance R1 and capacitance CPE1. Thus, R(Q(R(QR))) represented a biofilm formation model, in which R1 was the alloy charge transfer resistance, R2 was the biofilm resistance, CPE1 was the alloy capacitance, and CPE2 was the capacitance of the biofilm layer. In both circuits, Rs corresponded to the electrolyte resistance. Gunasekaran et al. [19] used the same circuits to fit various data. In this study, R(QR) was successfully utilized to fit the data obtained for the AS mixture without S. mutans, whereas R(Q(R(QR))) was found to be more suitable for describing the biofilm properties in the AS containing S. mutans.
At high frequencies, the phase angle shift was almost 0°, and the ohmic resistance dominated the impedance [17]. Hence, it could be concluded that the alloys exposed to the simulated oral environment were in the passive state. The Nyquist and Bode diagrams fitted using different equivalent circuits (Fig 4) indicate that all the studied samples exhibited capacitive behavior in the frequency range between 10−2 and 105 Hz, demonstrating very good agreement between the fitted and the experimental data (the corresponding chi-square values were below 1×10−3).
Table 4 lists the parameters obtained from the fitting procedure. The EIS results for the alloys treated with the sterile medium were fitted using the R(QR) circuit, whereas the alloys exposed to the medium containing S. mutans were fitted using the R(Q(R(QR))) circuit. The obtained data indicate that the alloy surfaces contained passive films, which were more homogeneous and compact in the absence of S. mutans species. In the presence of S. mutans, the studied alloys exhibited two time constants, and their parameters were more consistent with those of the R(Q(R(QR))) circuit, suggesting the formation of porous films on the alloy surfaces and thus the creation of biofilms on the surfaces of dental alloys. The solution resistance Rs was relatively low because of the presence of various salts in the utilized medium. The measured biofilm resistances suggest that the impedance first increased because of the biofilm formation and then decreased after the biofilm desorption.
Table 4. Impedance parameters obtained for the two alloys immersed in the AS solutions with and without S. mutans species.
Alloy | Medium | Rs (Ω) | Q1 (CPE) | R1 (kΩ) | Q2 (CPE) | R2(Ω) | ||
---|---|---|---|---|---|---|---|---|
Yo1(Ω-1 cm-2 sn) | n1 | Yo2(Ω-1 cm-2 sn) | n2 | |||||
CoCr | Without S. mutans | 37.9± 10.35 | 3.25±0.57 (×10−5) | 0.891±0.025 | 5483± 1320 | – | – | – |
CoCr | With S. mutans | 31.99±2.46 | 0.52±0.14 (×10−5) | 0.973±0.025 | 7443± 2459 | 2.46±0.58 (×10−5) | 0.923±0.011 | 4411± 2169 |
NiCr | Without S. mutans | 66.23±40.50 | 5.37±0.74 (×10−5) | 0.854±0.015 | 2537± 326 | – | – | – |
NiCr | With S. mutans | 21.16±6.08 | 1.01±0.47 (×10−5) | 0.970±0.030 | 2710± 570 | 2.88±0.90 (×10−5) | 0.915±0.015 | 2440± 1234 |
Bacterial surface adhesion
The adherence of S. mutans species to the CoCr and NiCr dental alloy surfaces treated with Solution 2 for 24 h is illustrated by the SEM images depicted in Fig 5a and 5b, respectively (relatively large clumps of cells can be observed at a magnification of 3 000×). In these images, S. mutans bacteria both adhere to the specimen surfaces and overlap with each other, while the resulting biofilm appears to be discontinuous. The obtained SEM results are consistent with the EIS data reported in the previous section, indicating that the presence of microorganisms is able to drastically change the electrochemical conditions at the metal/solution interface due to biofilm formation.
Potentiodynamic polarization measurements
The potentiodynamic polarization curves recorded for CoCr and NiCr alloys immersed in Solutions 1 and 2 for 24 h are shown in Fig 6. The icorr values measured for the samples exposed to S. mutans were slightly lower than the magnitudes obtained after treatment with Solution 1, and their corresponding OCPs (vs. Ag/AgCl) were shifted to the positive direction (Fig 1).
Table 5 lists the OCP (vs. Ag/AgCl) and icorr values for the dental alloys immersed in the two electrolytes. The icorr of the NiCr alloy was higher than that of the CoCr alloy, which suggests that the former material is more prone to corrosion in the AS medium with or without S. mutans.
Table 5. OCPs (vs. Ag/AgCl) obtained from Fig 2 and icorr values estimated from the potentiodynamic polarization studies of CoCr and NiCr alloys treated with Solutions 1 and 2 (x±s).
Alloy | Solution | OCP (vs. Ag/AgCl) (mV) (error) | icorr (μA/cm2) (error) |
---|---|---|---|
CoCr | AS without S. mutans | –175.25 (±37.05) | 0.195 (±0.032) |
CoCr | AS with S. mutans | –237.50 (±14.39) | 0.110 (±0.013) |
NiCr | AS without S. mutans | –244.50 (±25.01) | 1.683 (±0.160) |
NiCr | AS with S. mutans | –274.25 (±18.32) | 1.540 (±0.211) |
Discussion
This study was performed to investigate the dependence of the corrosion behavior of two dental alloys on the presence of S. mutans bacteria. An experimental medium for growing bacterial species was created to reproduce the human oral environment as closely as possible. All the utilized instruments used were carefully sterilized before each experiment, and particular attention was paid to preventing contamination due to external pollution.
When metals are immersed in test solutions, electrochemical reactions occur at the metal-solution interface. In this study, the OCPs of the tested samples exhibited negative shifts in the presence of S. mutans. Chang et al. [9] obtained similar results for pure Ti metal, Ti alloys, and Ni–Ti alloys exposed to S. mutans, which suggested that S. mutans or their byproducts produced during the corrosion process affected the OCPs of the tested samples at the metal-solution interface due to the formation of an oxide layer.
A potential (vs. Ag/AgCl) drop was observed for the CoCr and NiCr specimens after their exposure to S. mutans species, which could be related to their metabolism. The data obtained for both alloys exposed to S. mutans bacteria were consistent with the results of previous studies [20–25]. However, OCP measurements alone do not provide sufficient information for the accurate evaluation of the corrosion resistance of metals [26].
All samples examined in this study exhibited high impedance at low frequencies, suggesting the existence of a thin oxide passivation layer on the alloy surface, characterized by high corrosion resistance. When an alloy was immersed in the AS containing S. mutans for 24 h, biofilm formation occurred, which prevented charge transfer from the metal surface and thus decreased the alloy corrosion rate. Because all the studied samples demonstrated high impedance at low frequencies, it could be concluded that the alloys containing thin oxide passivation layers were characterized by high corrosion resistance in the specified medium [27,28]. The biofilm layer formed on the sample surface may act as a barrier that inhibits ionic conductivity or product diffusion [29].
The obtained SEM images showed that S. mutans species adhered to the sample surfaces and overlapped with each other, and that the biofilm formed by the bacteria was discontinuous. According to the EIS results, the charge transfer resistance of the two alloys exposed to S. mutans was higher than that of the alloys in the sterile medium. The icorr values measured for all samples decreased in the presence of S. mutans because of the absence of oxygen species from the metal-solution interface, indicating that the corresponding corrosion rate was also low. According to Chang et al. [9], the observed phenomenon can be explained by the ability of the oxide layer to resist attacks of S. mutans bacteria. Videla [30] suggested that corrosion inhibition was achieved due to the activity of sessile bacterial cells that formed a protective film and thus impeded the diffusion of corrosion products from the metal surface. To inhibit corrosion, it is necessary to localize the present nutrients species and thereby enhance the metabolic activity of the surface-assisted bacterial cells. When a sample was immersed in the AS mixture with S. mutans species, the microorganisms that adhered to the sample surface formed a biofilm, that prevented the charge transfer process from occurrence (in other words, it increased the alloy corrosion resistance) [9,31]. The resulting protective biofilm barrier prevented the diffusion of surface corrosion products, thus inhibiting the entire corrosion process [31,32].
The resulting biofilms composed of S. mutans monocultures were not only transformed from bacterial clusters into discrete layers, but also characterized by the increased thicknesses and heterogeneity. Moos et al. [33] showed that the microorganism growth on the metal surface leading to biofilm formation could affect the metal corrosion process by producing a gel phase which acted as a diffusion barrier and created concentration cells for metabolic and corrosion products. The authors of the described study also suggested that their results were applicable only to the well-known forms of corrosion and not to any new corrosion types. The produced biofilms (which contained differential aeration cells) caused local variations of the amounts of metabolic products, pH values, and dissolved oxygen levels.
By affecting the types and concentrations of the present ions (in addition to the pH and oxygen levels), the microorganisms induce significant variations in the physical and chemical characteristics of the environment as well as the electrochemical parameters utilized for measuring corrosion rates [34]. They affect metal corrosion resistance by changing the chemistry of the electrolytic solution on the metal surface. The generally accepted explanation of the microbial corrosion mechanism is that it begins with the formation of a biofilm on the metal surface because of the activity of aerobic microorganisms under favorable conditions [35]. Once the corrosion process is initiated, it is common to observe intense microbiological activity near corrosion sites. Direct counting of the organisms present in the bulk electrolyte is not sufficient for predicting their influence on the metal corrosion behavior; only the microorganisms that are in direct contact with metal surfaces affect metal corrosion properties. Videla et al. [34] noted that biofilms on alloy surfaces are usually formed within the first 24–72 h after the metal exposure to a bacteria-containing environment. The present microorganisms most likely do not participate directly in the corrosion process, but rather change the interfacial environment by creating concentration cells that facilitate corrosion resistance [36].
When the immersion time increases, the bacterial count increases, thus preventing corrosion by forming a protective layer on the alloy surface. Gunasekaran et al. [19] reported a significant reduction in the corrosion rate observed in the presence of Pseudomonas flava bacteria. The protective film formation began within the first 24 h of treatment and continued until 96 h have passed after which the produced film began to deteriorate. Therefore, the long-term effects of S. mutans on the corrosion behavior of CoCr and NiCr alloys should be investigated in detail in future studies.
Conclusions
In this work, the corrosion properties of NiCr and CoCr alloys immersed in the AS solution containing S. mutans for 24 h have been examined. The obtained EIS results confirmed that the biofilm formation played an important role in the alloy corrosion process, while the presence of S. mutans in the solution reduced the corrosion rate of the studied alloys. In particular, the protective biofilms formed on the surfaces of dental alloys were capable of inhibiting the corrosion process by acting as physical barriers to oxygen attacks. They did not participate directly in the corrosion reaction, but rather changed the interfacial environment by creating concentration cells facilitating corrosion resistance. The obtained results indicate that microbiologically influenced corrosion inhibition is a more common phenomenon than has been previously assumed.
Supporting information
Data Availability
All relevant data are within the paper and its Supporting Information files.
Funding Statement
Supported by the Research Fund of Science and Technology Commission of Shanghai (Municipality Grant No.08DZ2271100), Shanghai Leading Academic Discipline Project (Grant No.T0202).
References
- 1.Wataha JC. Biocompatibility of dental casting alloys: a review. J Prosthet Dent. 2000;83(2):223–34. [DOI] [PubMed] [Google Scholar]
- 2.Geurtsen W. Biocompatibility of dental casting alloys. Crit Rev Oral Biol Med. 2002;13(1):71–84. [DOI] [PubMed] [Google Scholar]
- 3.Upadhyay D, Panchal MA, Dubey RS, Srivastava VK. Corrosion of alloys used in dentistry: A review. Mater Sci Eng A. 2006;432(1):1–11. [Google Scholar]
- 4.Sun D, Monaghan P, Brantley WA, Johnston WM. Potentiodynamic polarization study of the in vitro corrosion behavior of 3 high-palladium alloys and a gold-palladium alloy in 5 media. J Prosthet Dent. 2002;87(1):86–93. [DOI] [PubMed] [Google Scholar]
- 5.Tuna SH, Pekmez NO, Keyf F, Canli F. The electrochemical properties of four dental casting superstructure alloys coupled with titanium implants. J Appl Oral Sci. 2009;17(5):467–75. 10.1590/S1678-77572009000500022 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Duffó GS, Farina SB. Corrosion behavior of a dental alloy in some beverages and drinks. Mater Chem Phys. 2009;115(1):235–8. [Google Scholar]
- 7.Reclaru L, Lüthy H, Eschler PY, Blatter A, Susz C. Corrosion behavior of cobalt-chromium dental alloys doped with precious metals. Biomaterials. 2005;26(21):4358–65. 10.1016/j.biomaterials.2004.11.018 [DOI] [PubMed] [Google Scholar]
- 8.Wylie CM, Shelton RM, Fleming GJ, Davenport AJ. Corrosion of nickel-based dental casting alloys. Dent Mater. 2007;23(6):714–23. 10.1016/j.dental.2006.06.011 [DOI] [PubMed] [Google Scholar]
- 9.Chang JC, Oshida Y, Gregory RL, Andres CJ, Barco TM, Brown DT. Electrochemical study on microbiology-related corrosion of metallic dental materials. Biomed Mater Eng. 2003;13(3):281–95. [PubMed] [Google Scholar]
- 10.Li F, An M, Liu G, Duan D. Effects of sulfidation of passive film in the presence of SRB on the pitting corrosion behaviors of stainless steels. Mater Chem Phys. 2009;113(2):971–6. [Google Scholar]
- 11.Mystkowska J. Biocorrosion of dental alloys due to Desulfotomaculum nigrificans bacteria. Acta Bioeng Biomech. 2016;18(4):87–96. [PubMed] [Google Scholar]
- 12.Kameda T, Oda H, Ohkuma K, Sano N, Batbayar N, Terashima Y, Sato S, Terada K. Microbiologically influenced corrosion of orthodontic metallic appliances.Dent Mater J. 2014;33(2):187–95. [DOI] [PubMed] [Google Scholar]
- 13.Kip N, van Veen JA. The dual role of microbes in corrosion. ISME J. 2015;9(3):542–51 10.1038/ismej.2014.169 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Wen ZT, Yates D, Ahn SJ, Burne RA. Biofilm formation and virulence expression by Streptococcus mutans are altered when grown in dual-species model. BMC Microbiol. 2010;10(1):111. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Bauer J, Costa JF, Carvalho CN, Grande RH, Loguercio AD, Reis A. Characterization of two Ni-Cr dental alloys and the influence of casting mode on mechanical properties. J Prosthodont Res. 2012;56(4):264–71. 10.1016/j.jpor.2012.02.004 [DOI] [PubMed] [Google Scholar]
- 16.Laurent F, Grosgogeat B, Reclaru L, Dalard F, Lissac M. Comparison of corrosion behaviour in presence of oral bacteria.Biomaterials. 2001;22(16):2273–82. [DOI] [PubMed] [Google Scholar]
- 17.Liu CL, Chu PK., Lin GQ, Yang DZ. Effects of Ti/TiN multilayer on corrosion resistance of nickel–titanium orthodontic brackets in artificial saliva. Corros Sci, 2007;49(10):3783–96. [Google Scholar]
- 18.Souza ME, Lima L, Lima CR, Zavaglia CA, Freire CM. Effects of pH on the electrochemical behavior of titanium alloys for implant applications. J Mater Sci Mater Med. 2009;20(2):549–52. 10.1007/s10856-008-3623-y [DOI] [PubMed] [Google Scholar]
- 19.Gunasekaran G, Chongdar S, Gaonkar SN, Kumar P. Influence of bacteria on film formation inhibiting corrosion. Corros Sci. 2004;46(8):1953–67. [Google Scholar]
- 20.Rasperini G, Maglione M, Cocconcelli P, Simion M. In vivo early plaque formation on pure titanium and ceramic abutments: a comparative microbiological and SEM analysis. Clin Oral Implants Res. 1998;9(6):357–64. [DOI] [PubMed] [Google Scholar]
- 21.Jack RF, Ringelberg DB, White DC. Differential corrosion rates of carbon steel by combinations of Bacillus sp., Hafnia alvei and Desulfovibrio gigas established by phospholipid analysis of electrode biofilm. Corros Sci. 1992;33(12):1843–53. [Google Scholar]
- 22.Mansfeld F, Little B. A technical review of electrochemical techniques applied to microbiologically influenced corrosion. Corros Sci. 1991;32(3):247–72. [Google Scholar]
- 23.Correa CB, Pires JB, Fernandes-Filho RB, Sartori R, Vaz LG. Fatigue and fluoride corrosion on Streptococcus mutans adherence to titanium-based implant/component surfaces. J Prosthodont. 2009;18(5):382–7. 10.1111/j.1532-849X.2009.00463.x [DOI] [PubMed] [Google Scholar]
- 24.Nagiub A, Mansfeld F. Evaluation of microbiologically influenced corrosion inhibition (MICI) with EIS and ENA. Electrochim Acta. 2002;47(13):2319–33. [Google Scholar]
- 25.Cheng S, Tian J, Chen S, Lei Y, Chang X, Liu T, et al. Microbially influenced corrosion of stainless steel by marine bacterium Vibrio natriegens: (I) Corrosion behavior. Mater Sci Eng C. 2009;29(3):751–5. [Google Scholar]
- 26.Eashwar M, Marathamuthu S, Sathiyanarayanan S, Balakrishnan K. The ennoblement of stainless alloys by marine biofilms: The neutral pH and passivity enhancement model. Corros Sci. 1995;37(8):1169–76. [Google Scholar]
- 27.Tamilselvi S, Raman V, Rajendran N. Corrosion behavior of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy. Electrochim Acta. 2006;52(3):839–46. [Google Scholar]
- 28.Oliveira NT, Guastaldi AC. Electrochemical stability and corrosion resistance of Ti–Mo alloys for biomedical applications. Acta Biomater. 2009;5(1):399–405. 10.1016/j.actbio.2008.07.010 [DOI] [PubMed] [Google Scholar]
- 29.Zhou D, Liu D, Mo C, Lv X. Corrosion behavior of 304 stainless steel in NaCl–(NH4)2SO4–NH4Cl solutions. J Chinese Soc Corros Protect. 2007;27(2):84–92 (in Chinese). [Google Scholar]
- 30.Videla HA. Biofilms and corrosion interactions on stainless steel in seawater. Int Biodeterior Biodegradation. 1994;34(3):245–57. [Google Scholar]
- 31.Videla HA, Herrera LK. Microbiologically influenced corrosion: Looking to the future. Int Microbiol. 2005;8(3):169–180. [PubMed] [Google Scholar]
- 32.Dubiel M, Hsu CH, Chien CC, Mansfeld F, Newman DK. Microbial iron respiration can protect steel from corrosion. Appl Environ Microbiol. 2002;68(3):1440–5. 10.1128/AEM.68.3.1440-1445.2002 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Moos O, Gümpel P. Comparison of the microbiological influence on the electro-chemical potential of stainless steel between macro- and micro-areas of specimens. Electrochim Acta. 2008;54(1):53–9. [Google Scholar]
- 34.Videla HA, Herrera LK. Understanding microbial inhibition of corrosion. A comprehensive overview. Int Biodeterior Biodegradation. 2009;63(7):896–900. [Google Scholar]
- 35.Ibars JR, Moreno DA, Ranninger C. Microbial corrosion of stainless steel. Microbiologia. 1992;8:63–75. [PubMed] [Google Scholar]
- 36.Xu LC, Chan KY, Fang HH. Application of atomic force microscopy in the study of microbiologically influenced corrosion. Mater Charact. 2002;48(2):195–203. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All relevant data are within the paper and its Supporting Information files.