Abstract
The deformation of bone when subjected to loads is not instantaneous but varies with time. To investigate this time-dependent behaviour sixteen bovine trabecular bone specimens were subjected to compressive loading, creep, unloading and recovery at multiple load levels corresponding to apparent strains of 2000–25,000 με. We found that: the time-dependent response of trabecular bone comprises of both recoverable and irrecoverable strains; the strain response is nonlinearly related to applied load levels; and the response is linked to bone volume fraction. Although majority of strain is recovered after the load-creep-unload-recovery cycle some residual strain always exists. The analysis of results indicates that trabecular bone becomes stiffer initially and then experiences stiffness degradation with the increasing load levels. Steady state creep rate was found to be dependent on applied stress level and bone volume fraction with a power law relationship.
Keywords: Creep-recovery, Viscoelastic, Bone volume fraction, Steady state creep rate, Creep compliance
Introduction
Trabecular bone, a composite cellular material with hierarchical structure, is generally treated as time-independent in biomechanical models.24 But in reality its response to mechanical loads is known to be time-dependent.5,13,19,23,29 Study of this time-dependent behaviour is important in several contexts such as: to understand energy dissipation ability of bone; to understand the age related non-traumatic fractures,26 to predict implant loosening due to cyclic load,30 to understand progressive vertebral deformity,25 and pre-clinical evaluation of total joint replacements.30 Consequently, trabecular bone’s time-dependent behaviour has great clinical relevance, but it has received relatively little attention.
A few studies have attempted to relate the creep behaviour with micro-architecture of bone. Kim et al. conducted one cycle of load-creep-unload-recovery experiments in which they applied a load corresponding to 2000μɛ and found that the samples with thinner trabeculae and greater connectivity were associated with increased logarithmic creep rate.13 Novitskaya et al. reported the changes in micro-architectural indices evaluated from micro computed tomography (μCT) before and after the creep; the study found that creep induced changes in trabecular separation and structural model index.23 Novitskaya et al. also found that the steady state creep rate was higher and the final creep strain was larger for samples with low bone volume fraction (BV/TV) (or apparent density).23
BV/TV or apparent density have been extensively employed to evaluate the time-independent stiffness of bone,11,14 which is then used in subject-specific models.33 Similar relationships between BV/TV and time-dependent response will permit their application in computational simulations where modelling time-dependent behaviour is important e.g., implant loosening. These relationships need to be considered at multiple loads to incorporate any load-level dependence. Manda et al. conducted creep experiments at a single load level (corresponding to a small apparent strain of 2000 με) and reported the relationships between BV/TV and linear viscoelasticity for trabecular bone.19
Previous studies have shown that under static conditions (or very slow strain rates) the strain in trabecular bone increases non-linearly with applied loads.10,16,17,21 However, time dependent behaviour with changing load levels has received limited attention. A few previous studies have considered multiple load levels but different loads were applied to different specimens i.e., each specimen was subjected to a single load level.4,5,20 Bowman et al. found a strong power law relationship between the steady state creep rate and the applied stress level, but when they included apparent density into the relation, the fit did not improve, in fact the r 2 value decreased.5 Also, Moore et al. related steady state creep rate to applied stress level, but this study also conducted cyclic loading tests on each sample at a single stress level.20 Multiple load levels were considered by one recent study in which a mathematical model for the recoverable (or elastic) strain18 with respect to load levels was developed; however, while this study alluded to BV/TV relationship with nonlinear viscoelasticity it did not develop it.
In summary, previous studies have shown that under static loading trabecular bone has a non-linear stress–strain behaviour and its time-independent elastic modulus can be related to BV/TV. Therefore, our hypothesis is that the time-dependent behaviour of trabecular bone can also be related to BV/TV and it is not linearly viscoelastic. The aim of this study is to determine how the creep-recovery response varies with load levels and how it can be related to BV/TV.
Materials and Methods
Sample Preparation
Bovine proximal femurs, female, under 30 months old, were obtained from a local butcher and stored in a freezer at −20 °C before further preparation. Femoral heads and trochanters were removed using a hacksaw after permitting the bone to thaw at room temperature. Transmission radiographs were taken to identify principal trabecular directions to ensure that samples cored in the following step were aligned along the principal direction. Cylindrical trabecular bone specimens were cored in a hydrated condition, to mitigate against temperature damage, using a 10.7 mm inner diameter diamond-coated coring tool (Starlite, Rosemont, USA). A low-speed saw (Buehler, Germany) was used to trim off growth plate if present and to cut the edges parallel. Thirteen femoral head trabecular bone specimens were obtained from 3 femoral heads and another three from two bovine trochanters (length: 24.8 ± 2.8 mm). The specimens’ dimensions were measured before being glued into brass end-caps using bone cement (Simplex, Stryker, UK) with the assistance of a custom made alignment tool. Effective length for each specimen was calculated as the length between end-caps plus half the length of bone embedded within the endcaps from each side.12 Mean effective length was 21.9 ± 2.7 mm.
Each specimen was placed in an epoxy tube filled with phosphate buffered saline (PBS), to ensure that the specimens remain hydrated at all stages of testing. All the specimens were scanned before mechanical testing using micro-computed tomography (μCT) scanner (Skyscan 1172, Bruker, Kontich, Belgium) and the system’s software was used to evaluate bone volume to total volume ratio (BV/TV), which was found to be in the range 15–54%. Degree of Anisotropic (DOA) and Trabecular Thickness (Tb.Th) were also evaluated and found to be in the range 2.04–16.95 and 168.3–277.3 μm, respectively.
Mechanical Testing
Mechanical tests were performed at room temperature using Zwick material testing machine (Model Z005/TH2A, Zwick Roell, Herefordshire, UK) with a 5000 N load cell. Each specimen was first preconditioned by subjecting it to 10 cycles of compressive loading with an amplitude of 0.1% apparent strain.5 After preconditioning, the specimen was unloaded, removed from the testing machine and allowed to recover for half an hour. Each specimen was then subjected to a compressive multiple load-creep-unload-recovery (MLCUR) cycles. Loading cycles comprised of instantaneous loading strain of 2000 με, 4000 με, 6000 με, 8000 με, 10,000 με, 15,000 με, 20,000 με, and 25,000 με apparent strains at a rate of 0.01 s−1. When the target strain was achieved the corresponding load was maintained for 200 s thereby permitting the specimen to undergo creep. In other words, this was a load-controlled experiment for creep and recovery while instantaneous loading and unloading were displacement controlled. Each loading step was followed by an unloading step to an almost zero force (2 N) and this force was maintained (recovery) for 600 s before the application of the next load cycle. These durations were selected after a number of preliminary tests which showed that the creep rate becomes constant in less than 200 s upon unloading and the recovery curves reach a plateau in less than 600 s. Typical strain response to MLCUR experiment is shown in Fig. 1 (only two cycles are shown for clarity) with the corresponding loading sequence as an inset in the figure. The experiment was stopped immediately if creep strain increased rapidly to beyond 5% in any loading cycle.
In each loading cycle the following strain responses were measured (Fig. 1): ɛ l is the instantaneous loading strain, ɛ ul is the instantaneous unloading strain, ɛ cre is the creep strain accumulated during the plateau loading phase, is the creep strain recovered after load removal, ɛ res is the residual strain or the unrecovered strain at the end of each cycle, is the steady state creep rate defined as the slope of the linear portion of the secondary creep curve
It is important to note that for a linear viscoelastic material, the ratio ɛ cre/ɛ l will be constant for different load levels and will vary linearly with stress level. Also for a viscoelastic material, strain will recover fully if sufficient time is allowed. Strain responses ɛ l and ɛ cre may include both recoverable and any irrecoverable components, while ɛ ul and ɛ rec only include the recoverable parts. We evaluated time-varying creep compliance, which is given by
1 |
where σ is the applied stress and ɛ cre(t) is the time-varying strain response due to corresponding constant stress level σ.
Results
In the MLCUR experiments strain output variables as defined in Fig. 1 were measured. Without exception, each specimen exhibited classical rapid primary and slow secondary regimes of creep behaviour across all stress levels.
All 16 specimens could be subjected to a stress level corresponding to 10,000 με (cycle 5) without tertiary creep. Four specimens demonstrated tertiary creep5 when subjected to stress level corresponding to 15,000 με (cycle 6), and only 3 specimens could be subjected to 20,000 με (cycle 7) level without tertiary creep. For the sake of completeness only the first 5 cycles were considered for most of the analyses.
We first examined three typical samples, with a range of bone volume fractions (BV/TV = 42.8, 25.1 and 18.6%) before considering all 16 specimens. Figure 2 shows time-varying creep compliance, (Figs. 2a, 2c, and 2e) and the corresponding steady state creep rate (Figs. 2b, 2d, and 2f) at different stress levels for three typical samples with significantly different BV/TV. It can be seen that for the dense sample (Fig. 2a) the time-dependent compliance initially becomes smaller with increasing load levels (the curves at lower stress levels are above those at higher stress levels) and then increases with the load level, at the largest applied stress (20.55 MPa). For the medium BV/TV sample (Fig. 2c), compliance decreases as the stress level is increased from 0.64 to 1.89 MPa but then increases when stress levels are increased to 2.44 MPa and then to 2.74 MPa. This decrease followed by an increase in compliance indicates elastic stiffening followed by elastic softening. For the dense sample, softening occurs at a stress level corresponding to a much higher strain in comparison to the medium BV/TV sample. The trend is followed by the low BV/TV sample (Fig. 2e), which demonstrates softening with increasing load levels right from the beginning.
This stiffening-softening phenomenon can also be seen from the steady state creep rate variation with stress level (Figs. 2b, 2d, and 2f), where we compare the experimentally measured steady state creep rate with the linear extrapolation from the first cycle. If the trabecular bone’s creep behaviour is linear viscoelastic, then the steady state creep rate will be proportional to the normalised stress level. Therefore, we extrapolated the steady state creep rate using the response from the first loading cycle (assumed linear), to predict the linear viscoelastic behaviour of trabecular bone. For a high BV/TV specimen (Fig. 2b), is lower than the linear viscoelastic prediction for the first few cycles but higher than the linear viscoelastic prediction at the highest load level applied. For a low BV/TV specimen (Fig. 2f), is higher than linear viscoelastic prediction even at lower stress levels while for the medium BV/TV specimen (Fig. 2d) is lower than the linear viscoelastic prediction for cycles 2 and 3 and higher than the linear viscoelastic prediction for cycles 4 and 5.
Considering all 16 specimens tested, the steady state creep rate () was found to vary from 0.07 to 4.51 με/s. The mean for load levels corresponding to 2000 με and 10,000 με were 0.30 με/s(±0.12) and 1.84 με/s(±1.42), respectively. Regression analysis of the experimental results showed that had strong nonlinear (power law) relation with normalised stress level (stress in each cycle divided by the modulus obtained from the first cycle) as defined by Bowman et al. 4 The steady state creep rate, , was also found to have a strong relationship with BV/TV. The best fit equation was found to be
2 |
where is in με/s, σ is in MPa and BV/TV is the bone volume fraction (.
Figure 3a shows a bar plot of the measured mean strain responses for different load cycles for all samples tested: initial loading strain (ɛ l), increase in creep strain during stress holding cycle (ɛ cre), instantaneous unloading strain (ɛ ul), decrease in strain during recovery (ɛ rec) and residual strain (ɛ res). Figure 3b shows the ratios of different strain responses against load cycles.
The ratio of ɛ ul/ɛ l increased with increasing corresponding strain level for all 16 specimens (Fig. 3b). Majority of instantaneous strain was recovered immediately upon unloading (average 86.5% for pooled data, r 2 = 0.99).
Our results showed that some residual strain, ɛ res, always exists at the end of 600 s of recovery after every unloading cycle and for all 16 specimens. The mean residual strain (Fig. 3a) (±SD) at the lowest load level corresponding to instantaneous loading strain of 2000 με was 542 με (±255) and for higher load level corresponding to instantaneous loading strain of 10,000 με was 1523 με (±604). The ratio of ɛ res/ɛ l was found to decrease with increasing load level (Fig. 3b) indicating that residual strain does not increase proportionally with load level.
Creep strain during stress holding cycle, ɛ cre, was found to increase with increasing load level (Fig. 3a). From cycle 1 to cycle 5 it increased from 377µε (±84) to 1365µε (±498), however, the ratio ɛ cre/ɛ l was found to decrease after the first load cycle after which it remained almost constant (Fig. 3b).
As expected, and ɛ rec both increased with increasing load level (Fig. 3a), from 1718 με (±266) and 180 με (±45) to 9048 με (±544) and 928µε (±157), respectively, and had relatively constant ratio of ɛ rec/ɛ ul (Fig. 3b) indicating that, as would be expected, the unloading phase is viscoelastic.
As mentioned above both ɛ cre and ɛ rec increased with increasing load levels (Fig. 3a), however, the ratio, ɛ rec/ɛ cre, had a very interesting trend—it first increased with load level and then decreased at higher load level (Fig. 3b). This trend again indicates elastic stiffening is followed by elastic softening with increasing load levels as demonstrated earlier by individual samples.
Discussion
Our study shows that residual strain arises even at low load levels, trabecular bone response is not linear viscoelastic and that bone demonstrates stiffening followed by elastic softening with increasing load levels.
It is now generally accepted that the yield strain of trabecular bone is independent of BV/TV.1,15 Typically, trabecular bone macroscopically yields below 0.8% strain in compression.21 Therefore, we applied compression forces equivalent to different strain levels (from 2000 με to 25,000 με), to examine the time-dependent behaviour of trabecular bone in pre- and post-yield regimes.
Examination of creep compliance curves for different samples showed that they vary with load levels. The samples with medium BV/TV showed an initially decreasing and then increasing creep compliance with increasing stress. This indicates that the samples first becomes stiffer and then experience softening (stiffness degradation). High BV/TV samples demonstrated decreasing creep compliance with stress indicating stiffening and an increase is observed only at much higher stress levels. For low BV/TV samples compliance increased with stress levels indicating softening from the start. This behaviour was also demonstrated by steady state creep rate comparison with creep rate linearly extrapolated from the first cycle: for low BV/TV samples the steady state creep rate was higher than linear extrapolation throughout; for high BV/TV samples it was below the linearly extrapolated values for most stress levels; and for medium BV/TV samples it was initially below the linear extrapolation and then above at higher stress levels. On average the ratio ɛ rec/ɛ cre initially increases and then decreases with stress level again demonstrating stiffening and softening behaviour, which has also been reported through nonlinear time-dependent constitutive models.18 A time-dependent constitutive model was previously developed by Fondrk et al. for cortical bone which incorporated stiffness degradation via damage but did not have stiffening demonstrated in this study.8 It is, however, not apparent why this occurs; it could be due to the reorganisation of ultrastructural components (i.e., mineral and collagen) in the bone matrix that make it stiffer initially followed by damage and buckling of trabeculae causing softening. Although the movement of collagen is constrained by mineral,2 sliding of collagen fibrils plays an important role in the time-dependent properties of bone.4,27,32 It is likely that collagen fibrils initially reorganise when the load levels are increased to resist deformation and maintain network integrity, and at larger loads micro-damage breaks this integrity.
Kim et al. reported mean of 0.22 με/s when the specimens were compressed at stress levels corresponding to 2000 με.13 This compares well with the mean value (0.30 με/s) found in this study. We also found that increased stress level does not result in a linear increase of which would be expected from a linear viscoelastic material, e.g., at stress level corresponding 10,000 με the steady state creep rate (1.84 με/s) was more than five times of the value at 2000 με. The steady state creep rate can be reasonably well related to stress level and BV/TV.
Ratio of ɛ ul/ɛ l, was found to be high (>80%) and increase slightly with increasing load levels. For a viscoelastic material in a creep-recovery experiment (instantaneous loading and unloading) this ratio is unity. The ratio ɛ ul/ɛ l < 1 indicates presence of irrecoverable strains arising during the loading phase. Yamamoto et al. found little difference between instantaneous loading and unloading strains.31 Kim et al. considered a single load level and found that 92.3% of strain was recovered immediately upon unloading.13 Kim et al. suggested that the difference between ɛ ul and ɛ l implies a reorganisation of micro- or ultra-structural components of the bone matrix caused by compressive creep and this reorganised state is not fully released upon unloading.13 Smallest ɛ ul/ɛ l ratio at low load level indicates that most reorganisation of the bone matrix happens at its first loading experience. The fact that the majority of the strain was recovered in the unloading phase was found to be true for all specimens and for all load cases.
Strain, ɛ res always exists even at low load levels, which implies that certain amount of irrecoverable strain is generated during loading and load holding. This study found that the average ratio of residual strain to loading strain (ɛ res/ɛ l) varied from 26% in the first loading cycle to 15% in the fifth loading cycle. Yamamoto et al. measured ɛ res of human L3 vertebral trabecular bone and reported mean values of 515 με and 1565 με for load levels corresponding to 750 με and 1500 με, respectively i.e., ɛ res/ɛ l ratios of 69 and 104%.31 Similarly, Kim et al. reported an average ɛ res/ɛ l value of 90% at load level corresponding to 2000 με.13 In both these studies the load holding time was much longer—Yamamoto et al. held the load for around 35 h while Kim et al. held it for 2 h. Yamamoto et al. extrapolated that the residual strain may fully recover in sufficiently long time (20 times the load holding time).31 Our tests showed that the decrease in ɛ res beyond 600 s was negligible i.e., these residual strains were largely irrecoverable. Large ɛ res/ɛ l ratios in the above cited studies in comparison to ours indicate that irrecoverable strains accumulate during load holding.
The ratio ɛ rec/ɛ ul was found to be constant in our study indicating that the unloading phase is viscoelastic. The ratio ɛ cre/ɛ l was found to decrease with increasing applied stress level initially and then become almost constant (it slightly increased at higher stress levels in samples which were tested beyond the 5 cycles). We found ɛ cre/ɛ l > ɛ rec/ɛ ul for all stress levels indicating presence of irrecoverable strains arising in the loading and load holding phases.
Our work suffers from a number of limitations. Firstly, all the tests were conducted at room temperature; creep behaviour has been reported to be temperature dependent.3,4 Secondly, the identification of instantaneous (loading and unloading) strain responses from the time-dependent strain response in MLCUR experimental curves was done using the loading platens of the machine rather than an extensometer attached to the central region with a more homogeneous mechanical environment, which may result-in small errors in the analysis of the results. Thirdly, a small force of 2 N was used during recovery phase to make sure that the end-caps were in contact with the load applicator to facilitate the measurement of the strain response. We believe the effect of this small load is negligible on the measured response.
An important clinical implication of the present study relates to the possible role of creep mechanisms and deformations in non-traumatic bone fractures. Non traumatic vertebral fracture present as shortening or height loss of bone without obvious trauma, and the progression is very slow and occurs gradually over a long period.22,25 It has been suggested that during normal daily activities, strain in bone usually does not exceed 3000 με.6 However, strain concentrations can arise at the bone implant interface e.g., when fractures are treated using external fixators.7 Also results from our study show that residual strain exists even at low stress level (equivalent to 2000 με), and it is accumulated with increasing stress levels. Trabecular bone with relative low BV/TV has larger value of steady state creep rate. Our study also shows that low BV/TV bone demonstrates stiffness degradation (or starts softening) even at low stress levels corresponding to 2000–4000 με. The BV/TV range considered by this study was 15–54%; previous studies have shown that BV/TV for human lumber spine can be around 8%,9 resulting in stiffness degradation at even lower loads. It has been previously suggested that creep deformity could accumulate over time in elderly human bones due to their reduced ability to remodel.28 Findings from current study indicate that elderly people who suffer from osteoporosis and consequently have low BV/TV are at greater risk of non-traumatic fractures even under normal physiological loads.
Acknowledgments
We gratefully acknowledge the financial support of EPSRC [Grant EP/K036939/1].
Conflict of interest
The authors confirm that there is no conflict of interest.
References
- 1.Bayraktar HH, Keaveny TM. Mechanisms of uniformity of yield strains for trabecular bone. J. Biomech. 2004;37:1671–1678. doi: 10.1016/j.jbiomech.2004.02.045. [DOI] [PubMed] [Google Scholar]
- 2.Bonar LC, Glimcher MJ. Thermal denaturation of mineralized and demineralized bone collagens. J. Ultrastruct. Res. 1970;32:545–548. doi: 10.1016/S0022-5320(70)80027-2. [DOI] [PubMed] [Google Scholar]
- 3.Bonfield W, Li CH. The temperature dependence of the deformation of bone. J. Biomech. 1968;1:323–329. doi: 10.1016/0021-9290(68)90026-2. [DOI] [PubMed] [Google Scholar]
- 4.Bowman SM, Guo XE, Cheng DW, Keaveny TM, Gibson LJ, Hayes WC, McMahon TA. Creep contributes to the fatigue behavior of bovine trabecular bone. J. Biomech. Eng. 1998;120:647–654. doi: 10.1115/1.2834757. [DOI] [PubMed] [Google Scholar]
- 5.Bowman SM, Keaveny TM, Gibson LJ, Hayes WC, McMahon TA. Compressive creep behavior of bovine trabecular bone. J. Biomech. 1994;27:301–310. doi: 10.1016/0021-9290(94)90006-X. [DOI] [PubMed] [Google Scholar]
- 6.Cowin SC. Elastic constants of cancellous bone. In: van Rietbergen B, Huiskes R, editors. Bone Mechanics Handbook. Boca Raton: CRC Press; 2001. p. 15. [Google Scholar]
- 7.Donaldson FE, Pankaj P, Simpson AHRW. Bone properties affect loosening of half-pin external fixators at the pin-bone interface. Injury. 2012;43:1764–1770. doi: 10.1016/j.injury.2012.07.001. [DOI] [PubMed] [Google Scholar]
- 8.Fondrk MT, Bahniuk EH, Davy DT. A damage model for nonlinear tensile behavior of cortical bone. J. Biomech. Eng. 1999;121:533–541. doi: 10.1115/1.2835084. [DOI] [PubMed] [Google Scholar]
- 9.Hildebrand T, Laib A, Müller R, Dequeker J, Rüegsegger P. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J. Bone Miner. Res. 1999;14:1167–1174. doi: 10.1359/jbmr.1999.14.7.1167. [DOI] [PubMed] [Google Scholar]
- 10.Keaveny TM, Guo E, Wachtel EF, McMahon TA, Hayes WC. Trabecular bone exhibits fully linear elastic behavior and yields at low strains. J. Biomech. 1994;27:1127–1136. doi: 10.1016/0021-9290(94)90053-1. [DOI] [PubMed] [Google Scholar]
- 11.Keaveny TM, Morgan EF, Niebur GL, Yeh OC. Biomechanics of trabecular bone. Annu. Rev. Biomed. Eng. 2001;3:307–333. doi: 10.1146/annurev.bioeng.3.1.307. [DOI] [PubMed] [Google Scholar]
- 12.Keaveny TM, Pinilla TP, Crawford RP, Kopperdahl DL, Lou A. Systematic and random errors in compression testing of trabecular bone. J. Orthop. Res. 1997;15:101–110. doi: 10.1002/jor.1100150115. [DOI] [PubMed] [Google Scholar]
- 13.Kim D-G, Shertok D, Ching Tee B, Yeni YN. Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone. J. Biomech. 2011;44:1660–1665. doi: 10.1016/j.jbiomech.2011.03.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Kopperdahl DL, Keaveny TM. Yield strain behavior of trabecular bone. J. Biomech. 1998;31:601–608. doi: 10.1016/S0021-9290(98)00057-8. [DOI] [PubMed] [Google Scholar]
- 15.Levrero-Florencio F, Margetts L, Sales E, Xie S, Manda K, Pankaj P. Evaluating the macroscopic yield behaviour of trabecular bone using a nonlinear homogenisation approach. J. Mech. Behav. Biomed. Mater. 2016;61:384–396. doi: 10.1016/j.jmbbm.2016.04.008. [DOI] [PubMed] [Google Scholar]
- 16.Li B, Aspden RM. Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis. J. Bone Miner. Res. 1997;12:641–651. doi: 10.1359/jbmr.1997.12.4.641. [DOI] [PubMed] [Google Scholar]
- 17.Linde F, Hvid I. The effect of constraint on the mechanical behaviour of trabecular bone specimens. J. Biomech. 1989;22:485–490. doi: 10.1016/0021-9290(89)90209-1. [DOI] [PubMed] [Google Scholar]
- 18.Manda K, Wallace RJ, Xie S, Levrero-Florencio F, Pankaj P. Nonlinear viscoelastic characterization of bovine trabecular bone. Biomech. Model. Mechanobiol. 2016 doi: 10.1007/s10237-016-0809-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Manda K, Xie S, Wallace RJ, Levrero-Florencio F, Pankaj P. Linear viscoelasticity—bone volume fraction relationships of bovine trabecular bone. Biomech. Model. Mechanobiol. 2016 doi: 10.1007/s10237-016-0787-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Moore TLA, O’Brien FJ, Gibson LJ. Creep does not contribute to fatigue in bovine trabecular bone. J. Biomech. Eng. 2004;126:321–329. doi: 10.1115/1.1762892. [DOI] [PubMed] [Google Scholar]
- 21.Morgan EF, Yeh OC, Chang WC, Keaveny TM. Nonlinear behavior of trabecular bone at small strains. J. Biomech. Eng. 2001;123:1–9. doi: 10.1115/1.1338122. [DOI] [PubMed] [Google Scholar]
- 22.Nicholson PHF, Haddaway MJ, Davie MWJ, Evans SF. Vertebral deformity, bone mineral density, back pain and height loss in unscreened women over 50 years. Osteoporos. Int. 1993;3:300–307. doi: 10.1007/BF01637315. [DOI] [PubMed] [Google Scholar]
- 23.Novitskaya E, Zin C, Chang N, Cory E, Chen P, D’Lima D, Sah RL, McKittrick J. Creep of trabecular bone from the human proximal tibia. Mater. Sci. Eng. C. 2014;40:219–227. doi: 10.1016/j.msec.2014.03.057. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Pankaj P. Patient-specific modelling of bone and bone-implant systems: the challenges. Int. J. Numer. Methods Biomed. Eng. 2013;29:233–249. doi: 10.1002/cnm.2536. [DOI] [PubMed] [Google Scholar]
- 25.Pollintine P, Luo J, Offa-Jones B, Dolan P, Adams MA. Bone creep can cause progressive vertebral deformity. Bone. 2009;45:466–472. doi: 10.1016/j.bone.2009.05.015. [DOI] [PubMed] [Google Scholar]
- 26.Rapillard L, Charlebois M, Zysset PK. Compressive fatigue behavior of human vertebral trabecular bone. J. Biomech. 2006;39:2133–2139. doi: 10.1016/j.jbiomech.2005.04.033. [DOI] [PubMed] [Google Scholar]
- 27.Sasaki N, Odajima S. Elongation mechanism of collagen fibrils and force-strain relations of tendon at each level of structural hierarchy. J. Biomech. 1996;29:1131–1136. doi: 10.1016/0021-9290(96)00024-3. [DOI] [PubMed] [Google Scholar]
- 28.Schaffler MB, Choi K, Milgrom C. Aging and matrix microdamage accumulation in human compact bone. Bone. 1995;17:521–525. doi: 10.1016/8756-3282(95)00370-3. [DOI] [PubMed] [Google Scholar]
- 29.Schoenfeld CM, Lautenschlager EP, Meyer PR. Mechanical properties of human cancellous bone in the femoral head. Med. Biol. Eng. 1974;12:313–317. doi: 10.1007/BF02477797. [DOI] [PubMed] [Google Scholar]
- 30.Taylor M, Cotton J, Zioupos P. Finite element simulation of the fatigue behaviour of cancellous bone. Meccanica. 2002;37:419–429. doi: 10.1023/A:1020848007201. [DOI] [Google Scholar]
- 31.Yamamoto E, Paul Crawford R, Chan DD, Keaveny TM. Development of residual strains in human vertebral trabecular bone after prolonged static and cyclic loading at low load levels. J. Biomech. 2006;39:1812–1818. doi: 10.1016/j.jbiomech.2005.05.017. [DOI] [PubMed] [Google Scholar]
- 32.Yamashita J, Furman BR, Rawls HR, Wang X, Agrawal CM. The use of dynamic mechanical analysis to assess the viscoelastic properties of human cortical bone. J. Biomed. Mater. Res. 2001;58:47–53. doi: 10.1002/1097-4636(2001)58:1<47::AID-JBM70>3.0.CO;2-U. [DOI] [PubMed] [Google Scholar]
- 33.Yosibash Z, Trabelsi N. Reliable patient-specific simulations of the femur. In: Gefen A, editor. Patient-Specific Modeling in Tomorrow’s Medicine. Berlin: Springer; 2011. pp. 3–26. [Google Scholar]