Skip to main content
Dental Press Journal of Orthodontics logoLink to Dental Press Journal of Orthodontics
. 2017 Jan-Feb;22(1):47–56. doi: 10.1590/2177-6709.22.1.047-056.oar

Effect of nanotechnology in self-etch bonding systems on the shear bond strength of stainless steel orthodontic brackets

Shaza M Hammad 1, Noha El-Wassefy 2, Ahmed Maher 3, Shafik M Fawakerji 4
PMCID: PMC5398842  PMID: 28444018

ABSTRACT

Objective:

To evaluate the effect of silica dioxide (SiO2) nanofillers in different bonding systems on shear bond strength (SBS) and mode of failure of orthodontic brackets at two experimental times.

Methods:

Ninety-six intact premolars were divided into four groups: A) Conventional acid-etch and primer Transbond XT; B) Transbond Plus self-etch primer; and two self-etch bonding systems reinforced with silica dioxide nanofiller at different concentrations: C) Futurabond DC at 1%; D) Optibond All-in-One at 7%. Each group was allocated into two subgroups (n = 12) according to experimental time (12 and 24 hours). SBS test was performed using a universal testing machine. ARI scores were determined under a stereomicroscope. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to determine the size and distribution of nanofillers. One-way ANOVA was used to compare SBS followed by the post-hoc Tukey test. The chi-square test was used to evaluate ARI scores.

Results:

Mean SBS of Futurabond DC and Optibond All-in-One were significantly lower than conventional system, and there were no significant differences between means SBS obtained with all self-etch bonding systems used in the study. Lower ARI scores were found for Futurabond DC and Optibond All-in-One. There was no significant difference of SBS and ARI obtained at either time points for all bonding systems. Relative homogeneous distribution of the fillers was observed with the bonding systems.

Conclusion:

Two nanofilled systems revealed the lowest bond strengths, but still clinically acceptable and less adhesive was left on enamel. It is advisable not to load the brackets immediately to the maximum.

Keywords: Nanotechnology, Self-etch, Shear bond strength, Scanning electron microscopy, Transmission electron microscopy.

INTRODUCTION

Bonding to enamel has always been a challenge in dental materials; Buonocore pioneered the use of acid-etch technique in 1955 1 and Newman was the first to recommend this technique in orthodontics. 2 Despite the reliability and acceptability of phosphoric acid-etching technique, it is necessary to decrease the number of eroded enamel rods and reduce the chair time without affecting the bond strength. 3

Self-etching primer (SEP) combining the acid-etching and primer have been introduced in orthodontics. Beside being a more simple and time-effective technique - by decreasing the bonding steps and dispensing the need for etching and priming -, it also avoids the undesirable effects of acid-etching and prevents salivary contamination bonding failure. 4 , 5 However, traditional multi-procedures etch and prime systems have shown higher shear bond strength (SBS). 3 , 6

The development of dental material sciences has introduced nanotechnology in bonding systems. 7 Nanotechnology or molecular nanotechnology is the production of functional structures and materials in the length scale of approximately 0.1-100 nanometers (1 nm = 10-9 m) by various physical or chemical methods. 8 Many theoretical predications based on the potential application of nanotechnology in dentistry have been made in the last 20 years, with varying levels of optimism. 9

Recently, composite resins containing nanofillers were introduced to reduce shrinkage during polymerization. 10 It was claimed that nanoparticles (NPs) provide more dimensional stability and reduce surface roughness. On the other hand, silica dioxide (SiO2) nanoparticles have been introduced in bonding systems with different shapes, sizes and levels. Futurabond DC (Voco, Cuxhaven, Germany) and Optibond All-in-One (Kerr, Orange, CA, USA) are self-etch bonding systems reinforced with different levels (1% and 7% respectively) of spherical (SiO2) nanoparticles. The manufacturers claimed that such particles enhance the bond strength to dentin and enamel. 7

In order to make a successful orthodontic treatment, it is important to assure adequate bond strength. Stress created by clinical procedure, normal mastication forces and the microleakage of the adhesive lead often to bond failure next to orthodontic brackets placement. 11 , 12 Prior studies reported that in order to resist short- and long-term forces in the oral cavity, materials must be sufficiently strong. 13 - 15 Other studies highlighted the necessity of early measuring the bond strength many times within 24 hours. 16 , 17

There have been not enough studies to explain the influence of nanotechnology in bonding systems on orthodontic procedures. So, the aim of the present study was to highlight the effect of this technology in self-etch adhesives on the shear bond strength and the mode of failure of stainless steel orthodontic brackets, in comparison with other SEP and conventional acid-etch with primer system after two times intervals (12 - 24 hours).

MATERIAL AND METHODS

The present sample consisted of 96 human premolars that were recently extracted for orthodontic purpose. The inclusion criteria for selection was: Sound (intact) teeth without dental caries, cavities, restoration, hypomineralized lesion, enamel hypoplasia, fracture or cracks. Following extraction, residues on the teeth were removed and washed away, then the teeth were stored in 0.9 percent NaCl solution at room temperature.

The root of each tooth was completely embedded in acrylic resin up to cementoenamel junction leaving the crown exposed. Each tooth was oriented so that the buccal surface was parallel to the applied force during SBS test. Blocks were randomly divided into four main groups according to the utilized adhesive system (n = 24). Each group was then subdivided randomly into equal two subgroups (n = 12), according to the time of test (12 or 24 hours). Acrylic blocks were color-coded to identify each test group.

Buccal surfaces were cleaned using a slurry of non-fluoridated pumice using rubber cup for 10 seconds, followed by rinsing with water spray and drying for 30 seconds. Stainless steel premolar brackets, 0.022-inch slot with mean area of each base =11.55 mm2 (3M Unitek, California, USA) were bonded as follows.

Bonding procedures

The bonding systems used in this study are shown in Table 1.

Table 1. Bonding materials used in the study.

Group Bonding System Manufacturer Composition Lot number
Group A Conventional Transbond XT Etchant - Ivoclar Vivadent, Schaan, Liechtenstein 37% phosphoric acid as etchant. T30617
Primer - 3M Unitek California, USA Primer: Silane-treated quartz, bisphenol A, diglycidyl ether, dimethacrylate, bis(2-hydroxyethyl ether), dichlorodimethyl silane, silica reaction products N513350
Group B Self-etching Transbond Plus SEP 3M Unitek California, USA Silane-treated quartz, glass reacted with hydrolyzed silane, polyethylene glycol, dimethacrylate, citric acid, dimethacrylate oligomer, silane-treated silica and bisphenol A, diglycidyl ether B579201
Group C Futurabond DC Voco Cuxhaven Germany Liquid 1: Acid-modified methacrylate (methacrylate ester) HEMA (2-hydroxyethyl methacrylate) Camphorquinone (photoinitiator) 1505034
Liquid 2: Water Ethanol Silica dioxide (SiO2) nanofiiler (1%)
Group D Optibond All-in-One Kerr Orange, CA USA Glycerol phosphate dimethacrylate (GPDM), mono- and di-functional methacrylate, monomers, HEMA, ethanol, acetone and water as solvents, fluoride-releasing fillers and silica dioxide (SiO2) nanofillers (7%) 5535902

For group A, the enamel surfaces of each tooth was etched with 37% phosphoric acid for 15 seconds, rinsed with water, air-dried for 10 seconds and conventional primer Transbond XT was applied, then light-cured for 10 seconds. The adhesive resin Transbond XT was applied to the bracket base and the bracket was placed on the enamel surface of each tooth and pressed. Excess adhesive was removed around the bracket base and the adhesive was light-cured using Elipar S10 LED curing light (3M ESPE, St. Paul, USA) for 40 seconds (10 seconds from each side, i.e. mesial, distal, occlusal and gingival).

For group B, Transbond Plus was used. A thin layer of SEP was rubbed on the enamel for 15 seconds and evaporated with gentle air, then, the bracket was bonded as in group A. For group C, Futurabond DC single dose was used. It is a self-etch bonding system that consists of two liquids. A drop of liquid A and a drop of liquid B were mixed, then the mixture was rubbed on the enamel surface for 20 seconds, air-dried and light-cured for 10 seconds, then the bracket was bonded as previously described.

For group D, Optibond All-in-One adhesive was used, which is an one-step self-etching bonding system. At first, the bottle was shaken, then the liquid was applied and rubbed on the enamel surface of each tooth for 20 seconds (this procedure was repeated twice), dried with gentle air and light-cured for 10 seconds, then the bracket was bonded.

Shear bond strength (SBS) testing

After bonding, the specimens were immersed in distilled water and stored for 12 or 24 hours at 37oC. SBS testing was done using an universal testing machine (Instron 3345, England). The chisel edge mounted on the cross-head of the machine contacted between the bracket base and occlusal wings of the bracket as close to the base as possible, at a speed of 1 mm/min. The bracket debonding force was recorded in Newton and then the bond strength was calculated in megapascal (MPa) considering the surface area of the bracket.

Adhesive remnant index (ARI)

After debonding, all the specimens were examined under stereomicroscope (SZ-PT, Olympus, Japan) at X10 magnification, in order to assess adhesive remnants on tooth surfaces using the ARI. 18 The ARI scores were: 0 = no adhesive left on the tooth; 1 = less than half of the adhesive left on the tooth, 2 = more than half of the adhesive left on the tooth, and 3 = all the adhesive left on the tooth.

Scanning electron microscopy (SEM) examination

After ARI test, one specimen from each subgroup was randomly selected for scanning electron microscopic (SEM) evaluation to assess the distribution of bonding materials on enamel surface. The root and lingual part of the crown was dissected using Isomet low speed (Buehler, Lake Bluff, IL, USA) under abundant irrigation. The specimens were cleaned in distilled water with ultrasonic agitation for 30 minutes and gently air-dried, mounted on aluminum stubs and sputter coated with gold prior to SEM examination (JEOL, JSM-6510LV, Japan) operated at an accelerating voltage of 30 kV. The examination of all groups was done at X1000 magnification and at X5000 magnification to determine the distribution of nanofillers more accurately. Representative images of different specimens were digitally captured and are presented in Figures 1 and 2.

Figure 1. Representative SEM photomicrographs of: conventional bonding system after 12 hours (A) and 24 hours (B); Transbond Plus system after 12 hours (C) and 24 hours (D).

Figure 1

Figure 2. Representative SEM photomicrographs of the two nanofilled bonding systems: Futurabond DC after 12 hours (A) and 24 hours (B); Optibond All-in-One after 12 hours (C) and 24 hours (D).

Figure 2

Transmission electron microscopy (TEM) examination

A drop from each utilized bonding system was loaded on carbon coated copper grid (200-mesh) and examined by TEM (JOEL, JEM-2100, Japan) to determine the size and distribution of the fillers within each bonding agent (Fig 3).

Figure 3. Representative TEM photomicrographs of the four used bonding systems; Transbond XT primer of conventional system (A), Transbond Plus (B), Futurabond DC (C), Optibond All-in-One (D).

Figure 3

Statistical analysis

Data were analyzed with SPSS version 21. One-way analysis of variance was used to compare SBS followed by the post-hoc Tukey test. The chi-square test was used to evaluate differences in ARI scores among the groups.

RESULTS

Shear bond strength (SBS)

The obtained SBS for the different four groups at 12 and 24 hours are given in Table 2. There were no statistically significant differences within each group at either time points (p > 0.05). Although the mean SBS observed with all different bonding systems at 12 hours were not statistically significant, the mean SBS obtained with the conventional system was statistically significant higher than that observed with Optibond All-in-One bonding system at 24 hours (p < 0.05).

Table 2. Shear bond strength values in megapascals of the bonding systems at 12 and 24 hours.

Time point Bonding system Mean Standard deviation Maximum Minimum p-value
12 hours A 8.86 2.69 13.24 4.37 p= 0.199
B 8.33 2.31 12.76 5.68
C 7.19 2.52 11.17 3.93
D 7.03 2.13 11.29 3.81
24 hours A 10.06a 3.02 14.53 5.49 p= 0.021*
B 9.08 3.11 12.88 4.54
C 7.27 2.40 10.67 4.36
D 7.15b 1.61 9.43 4.78

(A = 37% acid-etch and primer; B = Transbond plus; C = Futurabond DC; D = Optibond All-in-One). Groups with different superscript letters are statistically significantly different according to post-hoc Tukey HSD test, p = 0.043; *Significance was considered at p < 0.05.

Since there was no statistical significance of time points on the bond strength, the two subgroups (12 and 24 hours) were combined in Table 3. The combination showed that the SBS obtained with the two nanofilled systems used in this study were statistically significant lower than conventional system (p < 0.05), but there was no statistically significant difference between them. There was no statistically significant difference between the mean SBS obtained with Transbond Plus SEP and that obtained with other bonding systems.

Table 3. Shear bond strength values in megapascals of the bonding systems used in the study.

Bonding system N Mean Standard deviation Maximum Minimum P-value
A 24 9.46ab 2.86 14.53 4.37 p= .002*
B 24 8.71 2.71 12.88 4.54
C 24 7.23a 2.41 11.17 3.93
D 24 7.08b 1.85 11.29 3.81

(A = 37% acid-etch and primer; B = Transbond plus; C = Futurabond DC; D = Optibond All-in-One). Groups with superscript letters present statistically significant difference according to post-hoc Tukey HSD test (between A and C, p= 0.013; between A and D, p= 0.007).*Significance was considered at p < 0.05.

Adhesive remnant index (ARI) scores

Table 4 shows that there was no statistically difference between the observed ARI scores on the four groups at 12 and 24 hours (p > 0.05). In addition, there was no statistically difference for each group at the two time points. The two nanofilled self-etch bonding systems showed a tendency towards the score 1, however score 2 was noted in conventional system and Transbond Plus more than nanofilled systems at the two time points. These results indicated that there was less adhesive left on the enamel surface when the nanofilled bonding systems were used in this study.

Table 4. Distribution frequency of ARI scores for the bonding systems at debonding after 12h and 24h.

Bonding systems 12 hours X2 p-value 24 hours X2 p-value
0 1 2 3 0 1 2 3
A 0 8 4 0 X2 = 5.85 p = 0.119 NS 1 5 6 0 X2 = 14.30 p = 0.112 NS
B 0 10 2 0 0 8 4 0
C 0 11 1 0 1 10 1 0
D 0 12 0 0 1 10 0 1

NS, non-significant (A = 37% acid-etch and primer; B = Transbond plus; C = Futurabond DC; D = Optibond All-in-One).

SEM examination

The selected scanning electron photomicrographs were in accordance with the ARI stereomicroscope results. SE photomicrographs of total-etch system showed nearly even particles size that filled the porosities of etched enamel, and homogenous fillers distribution of bonding agent (Fig 1). Moreover, the scanning electron photomicrograph of Transbond Plus system showed a rather more condensed larger size particles with homogeneously distributed fillers on enamel that filled most of its porosities (Fig 1). Scanning electron microscope examination of the two nanofilled bonding systems revealed that the particles filled enamel porosities to an extent. The enamel porosities appeared smaller and shallower. These bonding agent systems seemed less homogeneous and had a tendency to aggregate in crowds and clusters. Photomicrograph of Optibond All-in-One showed larger size globular structures with higher concentration than DC and have more trends to accrue (Fig 2). SE microphotograph within each group showed that the bonding materials distribution was more homogeneous and showed more constancy when the debonding procedures were done after 24 hours in comparison with 12 hours (Fig 1 and Fig 2.

TEM examination

Figure 3 shows transmission electron Microscope (TEM) results for the bonding systems used in the study. TEM photomicrograph of Transbond XT primer in conventional system and Transbond Plus showed larger size of separated and distributed fillers (0.1 µm and more) and lesser filler concentration in comparison with nanofilled systems.

In nanofilled bonding systems (Futurabond DC and Optibond All-in-One), spherical nano-sized fillers had an average size of 20 nm. Futurabond DC system had less concentration of nanofiller, which had more homogeneous distribution within the bonding agent, while Optibond All-in-One system had higher concentration of nanofillers that accumulate in dense clusters.

DISCUSSION

The bond strength of orthodontic brackets has to be appropriate to support masticatory and orthodontic forces. Although acid-etching technique is a common useful technique for direct bonding of orthodontic brackets to enamel, the developed SEP adhesive systems can reduce chair time, eliminate the risk of contamination and provide intact enamel surface at the end of treatment. By the time, modern technologies utilizing new materials and substances are constantly developing to improve the quality of the bracket bonding to tooth structures, such as nanotechnology. 19

Nanoparticles (NPs) of various composition represent the most widespread use of nanotechnology in dentistry. 7 Incorporated nanofillers in adhesives compositions increased resistance against fracture and wear, provided higher dimensional stability and produced higher SBS than conventional adhesives. 20 Other studies reported comparable 21 , 22 or lower but still acceptable shear bond strength, 23 , 24 when nanofilled adhesives were used for bonding orthodontic brackets.

This study was conducted to evaluate the effect of spherical silicon dioxide (SiO2) nanoparticles with average size of 20 nm added to two self-etch adhesive systems by the manufacturers with different concentrations (Futurabond DC; 1% by weight and Optibond All-in-One; 7% by weight) on the shear bond strength and mode of failure of stainless steel orthodontic brackets bonded to human enamel. The manufacturers claim that nanoparticles enhance bond strength, since they act as cross-links that promote the bond strength to enamel and dentin. In this regard, nano-sized fillers lead to entire permeation of the bond so they improve the bond strength.

Previous studies 25 , 26 found that the shrinkage of polymerization was affected by the filler content, and another study 7 indicated that greater shrinkage was produced by smaller nanofillers size, which leads to decreased bond strength of self-etch bonding systems.

Mean SBS values obtained in this study with the two nanofilled self-etch systems (Futurabond DC, 7.23 ± 2.41 MPa; Optibond All-in-One, 7.08 ± 1.85 MPa) were insignificantly smaller than mean SBS value of Transbond Plus (8.71 ± 2.71), but they were significantly smaller than the conventional system (9.46 ± 2.86 MPa). This might be attributed to the higher polymerization shrinkage produced by nano-sized particles. Moreover, SEM and TEM examination revealed that the nano-sized filled bonding systems had less homogeneous distribution than the others, so less number of enamel porosities was filled. It was revealed that less noticeable etching of enamel surface was acquired by self-etching primer system, and bonding resulted in smaller and fewer resin tags. 27

There was no significant difference between mean SBS observed with the two nanofilled bonding systems. The SEM and TEM results showed that the nanoparticles in Optibond All-in-One had less homogeneous distribution and more tendency to aggregate in clusters. It was concluded that increasing nanofillers concentration within bonding systems had no effects on the shear bond strength of orthodontic brackets.

The results observed in this study showed that Transbond Plus bonding system had comparable SBS with conventional system, this is similar to the findings of previous studies. 4 , 5 On the other hand, self-etching bonding systems used in the study had a clinically acceptable mean SBS values since they were almost within the range (6-8 MPa) recommended by Reynolds. 28 However, only clinical testing can ensure clinical usefulness.

Testing of SBS at 24 hours after bonding procedure is generally preferred because it has been widely reported and allows comparison with other in vitro studies. However, initial stable time is highly important for clinical orthodontic practice, in which the archwire is usually placed after bracket bonding. 29 Regarding our results, there were no statistically significant differences between SBS values obtained with each tested bonding systems at the two time points. Conventional system revealed values of 8.86 ± 2.69 and 10.06 ± 3.02 MPa; Transbond Plus, 8.33 ± 2.31 and 9.08 ± 3.11 MPa; Futurabond DC, 7.19 ± 2.52 and 7.27 ± 2.40 MPa; and Optibond All-in-One, 7.03 ± 2.13 and 7.15 ± 1.61 MPa at 12 and 24 hours, respectively. However, SEM evaluation showed more homogeneity and constancy in bonding materials after 24 hours. From a clinical point of view, it is therefore advisable not to load the brackets immediately to the maximum.

An ideal orthodontic adhesive should have adequate bond strength while maintaining unblemished enamel after debonding. The ARI is one of the most commonly used methods of assessing the quality of adhesion between the composite and tooth, as well as between the composite and bracket base. 19 Regarding the present study, ARI scores were not significantly different from each other when time and bonding system were considered as variables.

Incomplete resin polymerization below the metal base of bracket usually occurs because the curing light cannot reach the adhesive behind the bracket mesh; for light-cured adhesive, most of the failures occurred at the adhesive-bracket interface, which were similar to other findings. 30 On the other hand, a score 2 of ARI was showed with conventional system and Transbond Plus in combination with a score 1. However, the two nanofilled self-etch systems had a high tendency towards a score 1. This could be clinically advantageous, because, when brackets fail at the enamel-adhesive interface, less adhesive remains, and tooth cleanup is likely to be easier and faster. 19

CONCLUSION

" The two nano-filled bonding systems revealed clinically acceptable SBS and presented lower ARI scores than the other bonding systems tested.

" An appropriate bond strength was obtained after 12 hours. However, the adhesives had strengthened after 24 hours.

Footnotes

"

The authors report no commercial, proprietary or financial interest in the products or companies described in this article.

REFERENCES

  • 1.Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res. 1955;34(6):849–853. doi: 10.1177/00220345550340060801. [DOI] [PubMed] [Google Scholar]
  • 2.Newman G. Current status of bonding attachments. J Clin Orthod. 1973 Jul;7(7):425–434. [PubMed] [Google Scholar]
  • 3.Mandall NA, Millett DT, Mattick CR, Hickman J, Worthington HV, Macfarlane TV. Orthodontic adhesives: a systematic review. J Orthod. 2002 Sep;29(3):205–210. doi: 10.1093/ortho/29.3.205. [DOI] [PubMed] [Google Scholar]
  • 4.Buyukyilmaz T, Usumez S, Karaman AI. Effect of self-etching primers on bond strength--are they reliable. Angle Orthod. 2003;73(1):64–70. doi: 10.1043/0003-3219(2003)073<0064:EOSEPO>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
  • 5.Grubisa HS, Heo G, Raboud D, Glover KE, Major PW. An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primer. Am J Orthod Dentofacial Orthop. 2004 Aug;126(2):213–219. doi: 10.1016/j.ajodo.2004.01.016. [DOI] [PubMed] [Google Scholar]
  • 6.Silverstone LM, Saxton CA, Dogon IL, Fejerskov O. Variation in the pattern of acid etching of human dental enamel examined by scanning electron microscopy. Caries Res. 1975;9(5):373–387. doi: 10.1159/000260179. [DOI] [PubMed] [Google Scholar]
  • 7.Basaran G, Ozer T, Devecioglu Kama J. Comparison of a recently developed nanofiller self-etching primer adhesive with other self-etching primers and conventional acid etching. Eur J Orthod. 2009 Jun;31(3):271–275. doi: 10.1093/ejo/cjn103. [DOI] [PubMed] [Google Scholar]
  • 8.Mitra SB, Wu D, Holmes BN. An application of nanotechnology in advanced dental materials. J Am Dent Assoc. 2003;134(10):1382–1390. doi: 10.14219/jada.archive.2003.0054. [DOI] [PubMed] [Google Scholar]
  • 9.Saunders SA. Current practicality of nanotechnology in dentistry. Part 1: Focus on nanocomposite restoratives and biomimetics. Clin Cosmet Investig Dent. 2009 Nov 30;1:47–61. [PMC free article] [PubMed] [Google Scholar]
  • 10.Argueta-Figueroa L, Scougall-Vilchis RJ, Morales-Luckie RA, Olea-Mejía OF. An evaluation of the antibacterial properties and shear bond strength of copper nanoparticles as a nanofiller in orthodontic adhesive. Aust Orthod J. 2015;31(1):42–48. [PubMed] [Google Scholar]
  • 11.Katona TR. Stresses developed during clinical debonding of stainless steel orthodontic brackets. Angle Orthod. 1997;67(1):39–46. doi: 10.1043/0003-3219(1997)067<0039:SDDCDO>2.3.CO;2. [DOI] [PubMed] [Google Scholar]
  • 12.Stanford SK, Wozniak WT, Fan PL. The need for standardization of test protocols. Semin Orthod. 1997 Sep;3(3):206–209. doi: 10.1016/s1073-8746(97)80071-0. [DOI] [PubMed] [Google Scholar]
  • 13.Whitlock 3rd BO, Eick JD, Ackerman RJ, Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994;106(4):358–364. doi: 10.1016/S0889-5406(94)70056-7. [DOI] [PubMed] [Google Scholar]
  • 14.Mitchell CA, O'Hagan E, Walker JM. Probability of failure of orthodontic brackets bonded with different cementing agents. Dent Mater. 1995 Sep;11(5):317–322. doi: 10.1016/0109-5641(95)80027-1. [DOI] [PubMed] [Google Scholar]
  • 15.Trites B, Foley TF, Banting D. Bond strength comparison of 2 self-etching primers over a 3-month storage period. Am J Orthod Dentofacial Orthop. 2004;126(6):709–716. doi: 10.1016/j.ajodo.2003.09.032. [DOI] [PubMed] [Google Scholar]
  • 16.Bin Abdullah M, Rock WP. The effect of etch time and debond interval upon the shear bond strength of metallic orthodontic brackets. Br J Orthod. 1996;23(2):121–124. doi: 10.1179/bjo.23.2.121. [DOI] [PubMed] [Google Scholar]
  • 17.Turk T, Elekdag-Turk S, Isci D. Effects of self-etching primer on shear bond strength of orthodontic brackets at different debond times. Angle Orthod. 2007;77(1):108–112. doi: 10.2319/011606-22R.1. [DOI] [PubMed] [Google Scholar]
  • 18.Artun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment. Am J Orthod. 1984;85(4):333–340. doi: 10.1016/0002-9416(84)90190-8. [DOI] [PubMed] [Google Scholar]
  • 19.Sharma S, Tandon P, Nagar A, Singh GP, Singh A, Chugh VK. A comparison of shear bond strength of orthodontic brackets bonded with four different orthodontic adhesives. J Orthod Sci. 2014;3(2):29–33. doi: 10.4103/2278-0203.132892. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Hegde MN, Hegde P, Bhandary S, Deepika K. An evalution of compressive strength of newer nanocomposite An in vitro study. J Conserv Dent. 2011;14(1):36–39. doi: 10.4103/0972-0707.80734. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Ahn SJ, Lee SJ, Kook JK, Lim BS. Experimental antimicrobial orthodontic adhesives using nanofillers and silver nanoparticles. Dent Mater. 2009;25(2):206–213. doi: 10.1016/j.dental.2008.06.002. [DOI] [PubMed] [Google Scholar]
  • 22.Silva CFLM, Correa MA, Correr L, Sobrinho, Moro A, Moresca RC, Correr GM. Shear bond strength of nanofilled flowable resins used for indirect bracket bonding. Braz J Oral Sci. 2012;11(4):458–462. [Google Scholar]
  • 23.Uysal T, Yagci A, Uysal B, Akdogan G. Are nano-composites and nano-ionomers suitable for orthodontic bracket bonding. Eur J Orthod. 2010;32(1):78–82. doi: 10.1093/ejo/cjp012. [DOI] [PubMed] [Google Scholar]
  • 24.Machado CT, Borges BC, Araujo GJ, Santos AJ, Dametto FR, Pinheiro FH. Influence of adhesion promoters and curing-light sources on the shear bond strength of orthodontic brackets. Indian J Dent Res. 2012 Nov-Dec;23(6):747–752. doi: 10.4103/0970-9290.111252. [DOI] [PubMed] [Google Scholar]
  • 25.James JW, Miller BH, English JD, Tadlock LP, Buschang PH. Effects of high-speed curing devices on shear bond strength and microleakage of orthodontic brackets. Am J Orthod Dentofacial Orthop. 2003;123(5):555–561. doi: 10.1067/mod.2003.S0889540602000197. [DOI] [PubMed] [Google Scholar]
  • 26.Faltermeier A, Rosentritt M, Faltermeier R, Reicheneder C, Müssig D. Influence of filler level on the bond strength of orthodontic adhesives. Angle Orthod. 2007;77(3):494–498. doi: 10.2319/0003-3219(2007)077[0494:IOFLOT]2.0.CO;2. [DOI] [PubMed] [Google Scholar]
  • 27.Fjeld M, Øgaard B. Scanning electron microscopic evaluation of enamel surfaces exposed to 3 orthodontic bonding systems. Am J Orthod Dentofacial Orthop. 2006;130(5):575–581. doi: 10.1016/j.ajodo.2006.07.002. [DOI] [PubMed] [Google Scholar]
  • 28.Reynolds I. A review of direct orthodontic bonding. Br J Orthod. 1975;2(3):171–178. [Google Scholar]
  • 29.Yamamoto A, Yoshida T, Tsubota K, Takamizawa T, Kurokawa H, Miyazaki M. Orthodontic bracket bonding: enamel bond strength vs time. Am J Orthod Dentofacial Orthop. 2006 Oct;130(4):435–435. doi: 10.1016/j.ajodo.2006.03.024. [DOI] [PubMed] [Google Scholar]
  • 30.Jou GL, Leung RL, White SN, Zernik JH. Bonding ceramic brackets with light-cured glass ionomer cements. J Clin Orthod. 1995;29(3):184–187. [PubMed] [Google Scholar]

Articles from Dental Press Journal of Orthodontics are provided here courtesy of Dental Press International

RESOURCES