Skip to main content
The International Journal of Behavioral Nutrition and Physical Activity logoLink to The International Journal of Behavioral Nutrition and Physical Activity
. 2017 Apr 26;14:55. doi: 10.1186/s12966-017-0513-z

Physical activity when riding an electric assisted bicycle

Sveinung Berntsen 1,, Lena Malnes 1, Aleksander Langåker 1, Elling Bere 1
PMCID: PMC5406898  PMID: 28446180

Abstract

Background

The objectives of the present study were to compare time spent cycling, exercise intensity, and time spent in moderate- (MPA) and vigorous intensity physical activity (VPA) when cycling on an E-bike and a conventional bicycle on two “cycling-to-work” routes with differences in topography, defined as a hilly and a flat route.

Methods

Eight adults (23–54 years, two women) cycled outdoors on a conventional bicycle and an E-bike, on a flat (8.2 km) and a hilly (7.1 km) route, resulting in 32 journeys. Duration, elevation, and oxygen consumption were recorded using a portable oxygen analyser with GPS. A maximal cardiorespiratory fitness test was performed on a cycle ergometer. Resting metabolic rate was obtained by indirect calorimetry with a canopy hood.

Results

The participants spent less time (median (IQR)) cycling on the E-bike compared with the conventional bicycle, on both the hilly (18.8 (4.9) vs. 26.3 (6.4) minutes) and the flat (20.0 (2.9) vs. 23.8 (1.8) minutes) routes. Lower exercise intensity was observed with the E-bike compared with the conventional bicycle, both on the hilly (50 (18) vs. 60 (22) % of maximal oxygen uptake) and the flat (52 (19) vs. 55 (12) % of maximal oxygen uptake) routes. In both cycling modes, most time was spent in MVPA (92–99%). However, fewer minutes were spent in MVPA with the E-bike than the conventional bicycle, for both the hilly (26% lower) and the flat (17% lower) routes. Cycling on the E-bike also resulted in 35 and 15% fewer minutes in vigorous intensity, respectively on the hilly and flat routes.

Conclusion

Cycling on the E-bike resulted in lower trip duration and exercise intensity, compared with the conventional bicycle. However, most of the time was spent in MVPA. This suggests that changing the commuting mode from car to E-bike will significantly increase levels of physical activity while commuting.

Keywords: Electrically assisted bicycle, Commuting, Intensity, Oxygen uptake, Pedalecs

Background

Physical activity can have a beneficial effect on health and fitness [1, 2]. Unfortunately, most adults are insufficiently active [3], below the recommended 150 min physical activity of moderate intensity or 75 min of vigorous intensity per week [4].

In the last decades, research has indicated an increase in exercise training during leisure time [5], and a reduction in household- [6], work-, and transport-related physical activity [5]. Promotion of transport-related physical activity has traditionally focused on walking and cycling [7]. Meanwhile, electric assisted bicycles (E-bikes) have become increasingly popular [8]. E-bike users have reported advantages such as higher speed with less effort, reduced travel time and easier to climb hills compared to conventional bicycles [9, 10]. In Europe, E-bikes provide electrical assistance only when the bike rider is pedalling [11], thus is partly human powered. Moreover, E-bikes seem to be highly used for commuting purposes [10, 1214]; therefore, it is essential to establish whether cycling with an E-bike can be health-enhancing, which depends on duration and intensity of physical activity [15].

Intensity can be measured as relative, such as percentage of maximal oxygen uptake (V.O2max) or absolute as metabolic equivalent of tasks (METs), where one MET is defined as resting metabolic rate (RMR). However, without direct measurements, RMR is usually replaced by a 1-MET reference value of 3.5 ml O2/kg/min [16]. Intensity when riding a conventional bicycle has been classified as vigorous, ranging from 6.4 to 8.2 METs [1619]. Recent studies on E-bikes have reported somewhat lower intensity, ranging from 4.1 to 6.1 METs [1922]. Some studies [2022] have compared cycling with no- and maximal electrical power; however, an E-bike is heavier than a conventional bicycle and therefore E-biking with the power switched off does not fairly represent cycling on a conventional bicycle [8, 23].

Gojanovic et. al.[19] investigated direct comparisons between cycling on an E-bike and a conventional bicycle. They found lower exercise intensity, measured as percentage of V.O2max, on an E-bike (55%) compared with a conventional bicycle (73%) on an uphill route. However, the lower cycling intensity is likely to vary according to topography. In addition, previous studies [1922] have estimated METs based on the standard 1-MET of 3.5 ml O2/kg/min. Since RMR may be influenced by age, gender, fat-free mass, body mass index (BMI) and fitness level [24, 25], direct measurements are preferred.

The objectives of the present study were to compare time spent cycling, exercise intensity, and time spent in moderate- (MPA) and vigorous intensity physical activity (VPA) when cycling on an E-bike and a conventional bicycle on two “cycling-to-work” routes with differences in topography, defined as a hilly and a flat route.

Subjects and Methods

Participants and study design

Six men and two women (23–54 years of age) met in the morning (07.00–10.00 am) for measurements of RMR. Thereafter, each participant performed four field-cycling tests outdoors and a maximal cardiorespiratory fitness test on a cycle ergometer in the laboratory. All participants were of Caucasian origin, non-smokers and without overt disease or use of medications.

The participants were given oral and written information about the study objectives and methods. Data was stored according to guidelines by the Norwegian Social Science Data Services.

Measurements

Height and body mass were measured (in light clothing, without shoes) using a stadiometer and a physician’s scale (Seca 713, Birmingham, UK).

Field tests

Oxygen uptake (V.O2) was measured with a portable oxygen analyser (MetaMax 3B-R2, CORTEX Biophysik GmbH, Leipzig, Germany) and a breathing mask, which were dressed according to the instructions of the manufacturer. MetaMax 3B-R2 has been found reliable and valid (approximately 10% difference between methods) when compared to the “Gold standard” the Douglas bag method and a secondary criterion machine known to be accurate, the Jaeger Oxycon Pro system [26]. Prior to using, the system was turned on for at least 30 min, and then calibrated prior to every test. First indoor calibrating of the gas analysers by using a reference gas (16% O2, 4% CO2), and then verifying the calibration against ambient air. Secondly, a volume calibration was performed using a standardised 3-L syringe (5530 series, Hans Rudolph, Inc., MO, USA). Sensor adjustments (ambient air calibration) were performed after bringing the MetaMax outside and before the first cycling session in each person. Speed and elevation were measured from GPS-coordinates using a GPS Kit for MetaMax® and cycling time was measured on-site by the test leader.

Total measurement period lasted between 120 and 150 min, where the participants cycled on two “cycling-to-work” routes, using a conventional bicycle (Cannondale 50/50 with an internal Shimano Nexus 8 speed hub, wheel size 26 `and bike weight of 12 kg (2005 model), Wilton, Connecticut, USA) and an E-bike cycling on maximal electrical power (RIXE with a 17 Ah/612 Wh Impulse battery, wheel size 28 `and bike weight of 27 kg (2014 model), Cloppenburg, Germany). The E-bike had a motor capacity of 250 W and a maximal speed of 25 km/h, with an active engine.

The two routes (a flat route of 8.1 km, and a hillier, but shorter, route of 7.1 km) started at the same place of departure, reached the same destination, and ended at the place of departure (simulating commuting, back and forth, from residence to a place of work). Altitude at both departure and destination was 18 m above sea level. The hilly route reached a maximal altitude of 83 m above sea level, including one hill that was climbed twice (to and from destination giving a total height difference of 130 m). Conversely, the flat route had no steep hills, and reached a maximal altitude of 35 m above sea level (total height difference 34 m). The route profiles are shown in Fig. 1.

Fig. 1.

Fig. 1

The elevation profile for the flat (solid) and the hilly (dotted) course

Each participant performed four trips, the order of which was randomised; these were 1) E-bike hilly, 2) E-bike flat, 3) Bike hilly and 4) Bike flat. There was a two minutes’ break between the experimental conditions. The participants were told to cycle at the intensity they would choose when commuting to work.

Laboratory tests

Before the field tests, RMR was obtained by indirect calorimetry with a canopy hood (Oxycon Pro, Jaeger BeNeLux Bv, Breda, Netherlands) according to international guidelines [27], using a standardised protocol. Prior to using, the system was turned on for at least 30 min, and then calibrated prior to every test. First calibrating of the gas analysers by using a reference gas (15% O2, 6% CO2), and then verifying the calibration against ambient air. Secondly, an automatic volume calibration was performed according to manufacturer’s recommendations. Participants were instructed to abstain from coffee, alcohol, smoking, exercise and not eat food, 12 h before measurements. The participants were placed under the canopy hood in a relaxed, supine position for 30 min and instructed to stay awake. Measurements were repeated on all participants until a 15-min steady state and the lowest V.O2 (ml/kg/min) value, average of one minute, defined RMR.

After the field tests, the participants had a 15 min’ break before they performed a test of cardiorespiratory fitness, measured as V.O2max. The protocol was performed using an electronically-braked cycle ergometer (Monark 839 Ergomedic, Varberg, Sweden), which was calibrated electronically before each test and mechanically after being moved. MetaMax 3B-R2 was calibrated before each test. During V.O2max tests, the ambient air temperature was 22 – 23 °C, relative humidity 50 – 60%, and barometric pressure 99.3 – 101.2 kPa. The initial workload was 50 W and was increased by 25 W every 2nd minutes until exhaustion. The pedalling rate (between 60 and 80 rpm) was instructed, and height of the saddle was adjusted individually. Minute ventilation (V.E), respiratory exchange ratio (RER) and V.O2 were recorded every minute by using the same portable gas analyser as in the field tests. Data was analysed with Metasoft Studio v.4.9 (Cortex Biophysik, Leipzig, Germany). The main criterion for having reached maximal effort was a subjective assessment by the test leader. The second criteria were RER above 1.00 and reporting perceived exertion (RPE) above 17 using the Borg-RPE-Scale [28].

Data processing

Data from start to end of cycling the sessions were imported into Microsoft Excel®, computed at one-minute intervals, and synchronised for further analysis. Percentage of V.O2 max was calculated by dividing V.O2 (ml/kg/min) from the field tests by maximal V.O2 (ml/kg/min) from the laboratory test. Measured METs and estimated METs were calculated by dividing participants RMR (V.O2 ml/kg/min) and the standard 1-MET value (3.5 ml O2/kg/min), respectively, by oxygen uptake during the field tests. Time spent in moderate and vigorous intensity physical activity was based on measured METs, which was categorised as moderate if 3 – 5.9 METs or vigorous if ≥6 METs [29]. Data are presented as median and interquartile range (IQR).

Results

Baseline characteristics of the participants are shown in Table 1. Results from a total of 32 trips are presented.

Table 1.

Physical characteristics of the eight participating subjects (median, interquartile range (IQR), minimum (Min) and maximum (Max)

Median IQR Min-Max
Age (yrs) 39 13 23–54
Body mass (kg) 74 13 64–86
Height (cm) 177 7 169–184
BMI (kg⋅m-2) 24 5 21–27
RMR (ml O2 ⋅ kg -1 ⋅ min-1) 3.0 0.2 2.6–3.8
HR rest (beats⋅ min-1) 45 6 34–49
V.O2max (ml · kg -1 · min-1) 45.0 17.4 36.3–81.8
HRmax (beats⋅ min-1) 177 9 169–185

Abbreviations: BMI Body Mass Index, RMR Resting Metabolic Rate, HRmax maximal heart rate, V.O2max maximal oxygen uptake

Time spent cycling

The median cycling time for the two routes combined was 19.9 min for E-bike and 25.1 min for conventional bicycle, i.e. the E-bike was 21% faster (Table 2 and Fig. 2). Median speed was 23.1 km/h for E-bike and 18.4 km/h for conventional bicycle, a difference of 4.7 km/h. The difference between E-bike and conventional bicycle was greater on the hilly route (E-bike 29% faster) than on the flat route (E-bike 16% faster).

Table 2.

Median (interquartile range) and percentage differences in cycling time, speed, exercise intensity (% of maximal oxygen consumption), energy expenditure (metabolic equivalents attained during cycling based on 1 MET–3.5 ml O2 · kg -1 · min-1 and measured RMR), moderate-to-vigorous intensity physical activity and vigorous intensity physical activity during electrically assisted- and conventional biking presented combined and stratified on flat and hilly

Total Flat Hilly
Cycling time (min)
 E-bike 19.9 (3.1) 20.0 (2.9) 18.8 (4.9)
 Conventional 25.1 (3.9) 23.8 (1.8) 26.3 (6.4)
 Δ (%) -21 -16 -29
Speed (km · h-1)
 E-bike 23.1 (3.7) 24.6 (3.5) 22.7 (5.6)
 Conventional 18.4 (2.7) 20.7 (1.5) 16.3 (4.2)
 Δ (%) 21 16 29
% V.O2max
 E-bike 51 (27) 52 (19) 50 (18)
 Conventional 58 (26) 55 (12) 60 (22)
 Δ (%) -12 -6 -17
Measured METs (ml · kg -1 · min-1)
 E-bike 8.5 (3.1) 8.4 (3.3) 8.4 (3.2)
 Conventional 10.9 (2.7) 10.3 (2.8) 10.8 (3.1)
 Δ (%) -22 -19 -22
Estimated METs (ml · kg -1 · min-1)
 E-bike 6.9 (2.1) 6.9 (1.9) 6.8 (2.5)
 Conventional 8.4 (1.8) 8.1 (2.5) 8.5 (2.1)
 Δ (%) -18 -15 -20
MVPA (min)
 E-bike 19.0 (2.7) 19.5 (3.4) 18.0 (2.8)
 Conventional 23.9 (3.6) 23.5 (2.6) 24.3 (4.6)
 Δ (%) -21 -17 -26
VPA (min)
 E-bike 15.5 (4.1) 17.5 (5.3) 14.0 (2.5)
 Conventional 20.8 (3.1) 20.5 (4.0) 21.5 (1.8)
 Δ (%) -26 -15 -35

Abbreviations: E-bike electrically assisted bicycle, Δ percentage difference between electrically assisted- and conventional biking; V.O2 oxygen consumption, METs Metabolic Equivalents, MVPA moderate-to-vigorous intensity physical activity, VPA vigorous intensity physical activity

Fig. 2.

Fig. 2

Time spent cycling (a), percentage of VO2max (%VO2max) (c) and time spent in moderate (b) and vigorous (d) intensity physical activity per 10 km during flat (empty) and hilly (filled) on the E-bike (quadrate) and the regular bicycle (triangle). Presented as median and interquartile range

Exercise intensity

Exercise intensity presented as V.O2max for the E-bike and the conventional bicycle was for the routes combined 51 and 58%, respectively (a difference of 12%). The difference between the bikes was greater on the hilly route than on the flat route, 17 vs 6%, respectively. Expressed as METs, the exercise intensity over the two routes using an E-bike was measured to be 8.5 METs, while using conventional bicycle was measured to be 10.9. Using METs from the estimated resting metabolic rate of 3.5 ml O2/kg/min, the estimated METs were respectively 6.9 and 8.4.

Time spent in moderate- and vigorous intensity physical activity

In total, 19.0 and 23.9 min were spent in MVPA when using measured METs, respectively for E-bike and conventional bicycle, which was 95% of total cycling time for both cycle types. Most of the time in both the hilly and flat routes were spent in MVPA, however, due to less time spent cycling on the hilly route, the time in MVPA (26% lower), and especially in VPA (35% lower) was lower using E-bike compared to conventional bicycle.

Discussion

In the present study, comparing e-biking to conventional bicycling on two different routes simulating relevant cycling to work options, e-biking was faster and less intensive than conventional bicycling, especially on the hilly route. However, 95% of time spent biking, both for e-bike and conventional bike, were considered to be MVPA.

E-biking were faster than conventional bicycling, and reduced the time cycling with almost 30% in the hilly route. These results support the findings from previous studies regarding lower trip duration with an E-bike compared with a conventional bicycle [19, 30, 31], due to a higher speed. Gojanovic et al. [19] observed that when riding an E-bike, speed was on average 6 km/h higher than on a conventional bicycle, on the same route, similar to the 5 km/t in the present study. Furthermore, observational studies found on average 2 km/h higher speed in E-bike cyclists compared with individuals travelling by conventional bicycles [30, 31]. Schleinitz et al. [30] also illustrated that age, road gradient, and bicycle infrastructure may influence differences in cycling speed and trip duration between E-bikes and conventional bicycles.

E-biking was less intense than conventional bicycling, both relative (a 17% lower V.O2max) and absolute (36% lower time spent in VPA). To the authors´ knowledge, in only one published study exercise intensity has been measured relative to cardiorespiratory fitness when riding an E-bike and a conventional bicycle. Gojanovic et al. [19] observed 55% of V.O2max when subjects cycled on an E-bike, and 72% of V.O2max during conventional bicycling, and slightly higher compared to the 51 and 58% in present study. In the present study, when the participants cycled on the conventional bicycle, the difference between the hilly and flat route was larger, probably due to higher physical effort cycling uphill without electrical support. Therefore, the findings may suggest that conventional bicycles are more sensitive to individual- and environmental factors, such as topography. Compared to studies on conventional bicycles, Oja and colleagues [32] supported the present findings, in 68 commuting adults, as the relative intensity was 57–65% of V.O2max, whereas Geus et al. [17] observed a higher intensity of 77–79% of V.O2max.

Exercise intensity, presented as METs, was in the present study also lower when subjects cycled on the E-bike compared to the conventional bike, however, figures for the hilly and flat routes were similar. The explanation for similar average MET-values during the flat and hilly routes are the periods of downhill with lower energy demand following the periods of ascending during hilly biking. A few previous studies have presented MET-values (4–6 METs) for E-bikes when cycling on a varied terrain [1922]. These findings were similar, or somewhat lower, to the estimated METs in the present study, however, considerable lower than the measured METs. Presenting energy expenditure or exercise intensity using the standard 1-MET value (3.5 ml O2/kg/min) may result in lower reported levels in individuals since the standard 1-MET value has been reported to be overestimating resting metabolic rate by 35 and 14% in individuals with a mean BMI of 30 and 20 kg/m2, [25], respectively, and similar to the present study (resting metabolic rate of 3.0 ml O2/kg/min). However, our results indicate that both using the standard 1-MET or measured RMR, e-biking can be categorised as at least MVPA.

E-biking was faster and less intense, making it suited for busy modern lives. It will get you quicker to work and you might not need a shower. But, on the other hand, less time spent cycling at a lower intensity is not ideal as most people are inactive. However, most of the time spent cycling on both the E-bike and the conventional bicycle, in both routes, was spent in MVPA.

The present findings indicate that due to lower intensity and trip duration, an E-bike needs to be used more frequently or to cover longer distances, to achieve the same health benefits [15], as adults commuting by a conventional bicycle. On the other hand, in several European nations, most adults do commute by motorised transportation to work [33], which according to Costa et al. [18] can be categorised as sedentary behaviour or light intensity physical activity (below 3 METs). Since the present findings indicate at least a moderate intensity of physical activity when e-biking, an increase in the level of transport-related physical activity will follow switching from car commuting to E-bikes, and more individuals probably meeting the physical activity recommendations. Also, considering that frequently reported barriers to cycling or walking for transport have been travel time [3437] and physical effort [36, 37]; the E-bike seems to be a good option for those living too far away from work to walk or cycle with a conventional bike.

Strength and limitations

The main strengths of the present study were the objective measurements of RMR, direct measurements of V.O2max in the laboratory and V.O2 during the field tests as well as using GPS to measure elevation and distance covered. However, due to a small sample size not the findings are presented as descriptive rather than analytical. During the field tests, the participants may have cycled at a higher intensity, due to participating in an experimental study. In addition, the cycling trips is not necessarily representative to all cycling trips in Norway. The participants performed the four field tests on the same day, which may have affected our results. However, the route and type of bicycle were selected in random order.

Conclusion

Cycling on the E-bike resulted in lower trip duration and exercise intensity, compared with the regular bicycle. However, most of the time was spent in MVPA. Therefore, changing commuting mode from car to E-bike will significantly increase levels of physical activity while commuting.

Acknowledgements

Thanks to the participating individuals in the present study.

Funding

Funding was provided by the University of Agder, Norway.

Availability of data and materials

The datasets during and/or analysed during the current study are available from the corresponding author on reasonable request.

Authors' contributions

The project was performed at the Department of Public Health, Sport and Nutrition, University of Agder, Norway. Conceived and designed the study: SB, EB. The collection, analysis and/or interpretation of data: SB, EB and AL. Wrote the manuscript: SB, EB and LM. Edited and revised manuscript: SB, LM, AL and EB. All authors have approved the final version of the manuscript.

Authors’ information

Not applicable

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable

Ethics approval and consent to participate

The participants signed an informed consent form after being given oral and written information about the study objectives and methods. Research clearance was obtained from The Norwegian Social Science Data Services.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Abbreviations

V.O2max

maximal oxygen uptake

V.E

minute ventilation

V.O2

oxygen uptake

BMI

Body mass index

E-bike

Electrical assisted bicycle

IQR

Inter quartile range

Km

Kilometres

km/h

Kilometres per hour

kPa

Kilopascal

METs

Metabolic equivalents

Min

Minutes

MVPA

Moderate-to-vigorous intensity physical activity

RER

Respiratory exchange ratio

RMR

Resting metabolic rate

RPE

Reporting perceived exertion

Rpm

Revolutions per minutes

W

Watt

Contributor Information

Sveinung Berntsen, Phone: +47 38 14 10 45, Email: sveinung.berntsen@uia.no.

Lena Malnes, Email: lena.h.malnes@gmail.com.

Aleksander Langåker, Email: alangaker@me.com.

Elling Bere, Email: elling.bere@uia.no.

References

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The datasets during and/or analysed during the current study are available from the corresponding author on reasonable request.


Articles from The International Journal of Behavioral Nutrition and Physical Activity are provided here courtesy of BMC

RESOURCES