Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2017 Apr 28;7:46675. doi: 10.1038/srep46675

WINCS Harmoni: Closed-loop dynamic neurochemical control of therapeutic interventions

Kendall H Lee 1,2,3,*, J Luis Lujan 1,2,*, James K Trevathan 4, Erika K Ross 1, John J Bartoletta 1, Hyung Ook Park 1, Seungleal Brian Paek 4, Evan N Nicolai 1, Jannifer H Lee 1, Hoon-Ki Min 1,2, Christopher J Kimble 5, Charles D Blaha 1,a, Kevin E Bennet 1,5
PMCID: PMC5408229  PMID: 28452348

Abstract

There has been significant progress in understanding the role of neurotransmitters in normal and pathologic brain function. However, preclinical trials aimed at improving therapeutic interventions do not take advantage of real-time in vivo neurochemical changes in dynamic brain processes such as disease progression and response to pharmacologic, cognitive, behavioral, and neuromodulation therapies. This is due in part to a lack of flexible research tools that allow in vivo measurement of the dynamic changes in brain chemistry. Here, we present a research platform, WINCS Harmoni, which can measure in vivo neurochemical activity simultaneously across multiple anatomical targets to study normal and pathologic brain function. In addition, WINCS Harmoni can provide real-time neurochemical feedback for closed-loop control of neurochemical levels via its synchronized stimulation and neurochemical sensing capabilities. We demonstrate these and other key features of this platform in non-human primate, swine, and rodent models of deep brain stimulation (DBS). Ultimately, systems like the one described here will improve our understanding of the dynamics of brain physiology in the context of neurologic disease and therapeutic interventions, which may lead to the development of precision medicine and personalized therapies for optimal therapeutic efficacy.


Normal brain function relies on a precise and delicate balance of chemical signaling mediated by the release of specific neurotransmitters. When this balance is disrupted by disease or injury, the results can be devastating. For example, decreased dopamine release is associated with anxiety, depression, cognitive impairment, fatigue, balance difficulties, and tremor1,2,3,4,5,6. Similarly, decreased levels of serotonin are associated with depression, anxiety, migraine headaches, impaired cognitive function, and insomnia7,8. These and other brain disorders affect up to one billion people worldwide9.

The last 30 years have seen a significant expansion of neuromodulation techniques that have become established forms of treatment for patients with certain brain disorders that do not respond to conventional pharmacologic, behavioral, and surgical interventions. These neuromodulation treatments typically involve electrical stimulation of anatomical targets linked to pathological neural activity associated with a specific disorder10. For example, electrical stimulation of deep brain structures, known as deep brain stimulation (DBS), has received approval from the United States Food and Drug Administration (FDA) for the treatment of advanced Parkinson’s disease (PD) and tremor11,12,13. Similarly, clinical DBS trials are underway in the United States (with CE Mark approval for clinical use in Europe) for the treatment of depression and epilepsy, with humanitarian device exemptions received for treatment of dystonia and obsessive-compulsive disorder14. Additionally, vagal nerve stimulation (VNS) has received FDA approval for treatment of pharmacoresistant epilepsy and major depressive disorder15.

Although the precise effects underlying therapeutic response remain a matter of debate, both clinical and preclinical studies suggest that proximal and distal changes in neural activity and neurotransmitter release are implicated in the neurobiology of disease16,17,18. For example, it has been suggested that transcranial magnetic stimulation (TMS) modulates γ-aminobutyric acid (GABA) activity19 mediating cortical excitability involved in Parkinson’s disease20, amyotrophic lateral sclerosis21, Tourette syndrome22 and dystonia23. Other studies suggest that VNS evokes norepinephrine release in the locus coeruleus, which may be involved in the therapeutic effects of neuromodulation for epilepsy24. DBS of the subthalamic nucleus (STN), a successful therapy for PD, has been associated with increased electrophysiological activity in neurons within the globus pallidus (GP)25,26,27 and substantia nigra28,29,30. Stimulation of the ventral capsule/ventral striatum and cingulate cortex for the treatment of major depressive disorder has been found to normalize neural activity in the anterior insula as well as the prefrontal, premotor, and dorsal anterior cingulate cortices31,32. DBS of the thalamic ventral intermedius (VIM) nucleus for treatment of tremor has been shown to change neural activation across the cerebello-thalamo-cortical circuit33,34. This change is associated with reduction of pathologic oscillations in cortical, thalamic, and cerebellar nuclei leading to tremor reduction in patients with essential tremor35,36. Interestingly, pre-clinical studies have shown that therapeutic neuromodulation strategies such as DBS of the STN, the medial forebrain bundle (MFB), and nucleus accumbens evoke the release of dopamine and adenosine in the striatum and nucleus accumbens, structures associated with control of motor and/or limbic behavior18,37. Most patients suffering from neurologic disease are treated with pharmacological agents that manipulate neurochemical changes, either as a primary intervention, or as an adjunct to other forms of therapy such as neuromodulation. Therefore, it is likely that the therapeutic effects of many clinical interventions may be mediated, at least in part, by proximal and distal changes in neurochemical activity18.

In order to measure neurochemical activity, a number of investigational devices have been previously developed (Table 1). However, important limitations with these devices, including but not limited to wired links to control computers, large physical dimensions, and lack of a built-in synchronized stimulation and recording system, have made neurochemical characterization of in vivo disease processes and therapeutic interventions, particularly in large animal models of behavior, a difficult endeavor. To begin addressing these limitations, we previously developed a portable wireless instantaneous neurotransmitter concentration sensing (WINCS) system38,39 that enabled high temporal resolution measurement of neurotransmitters and other electroactive molecules via fast scan cyclic voltammetry (FSCV). Unfortunately, its single recording channel limited its use for measurement of network changes in neurochemical activity. In addition, WINCS did not provide synchronized stimulation and neurochemical recording. Thus, characterization of stimulation-evoked neurochemical responses was difficult due to inconsistent delays between electrical stimulation and neurochemical measurements and, above all, the presence of stimulation artifacts superimposed on the neurochemical signals of interest. To address these limitations, we developed a next-generation research platform called WINCS Harmoni, designed for wireless multi-channel in vivo real-time measurement of neurochemical activity. WINCS Harmoni enables analysis and characterization of neurochemical activity, synchronization of neurochemical measurements and electrical stimulation, as well as real-time closed-loop control of neurochemical responses via titration of stimulation parameters and therapeutic optimization.

Table 1. A comparison of commonly available devices capable of FSCV.

  WINCS Harmoni (This Work) WINCS42,71 UEI (Universal Electrochemical Instrument)72,73 P. PhillipsFSCV System74,75 Pinnacle FSCV System (wireless system)76 WaveNeuro FSCV System77 Reference 600+78 EZstat-Pro79
Organization Mayo Clinic Mayo Clinic University of North Carolina University of Washington Pinnacle Pine Instruments Gamry NuVant Systems
Number of FSCV channels 4 1 4 4 1 1 1 1
Wireless capabilities yes yes no no yes no no no
Built in synchronized stimulator yes no no no no no no no
Voltage range 2 V – adjustable center 2.5 V – adjustable center ±10 V ±10 V −0.6 V to + 1.5 V  ± 3.3 V  ± 12 V  ± 10 V
Maximum linear scan rate 1200 V/s 1000 V/s  > 10,000 V/s 500 V/s 1000 V/s 5000 V/s 1500 V/s 500 V/s
Current range  ± 1 μA, ± 2 μA, ± 3 μA, ± 4 μA, ± 5 μA, ± 6 μA, ± 7 μA, ± 8 μA  ± 1.25 μA 2 μA default - defined by headstage 1.22 μA 5.6 μA, 50.6 μA 2 μA default - defined by headstage 11 ranges (60 pA–600 mA) 1 μA, 100 μA, 10 mA, 1 A
DAC resolution 16-bit 12-bit 16-bit 12-bit 18-bit 16-bit 16-bit 16-bit
DAC update rate 100 kS/s 100 kS/s 2 MS/s 1 MS/s 1000 S/voltammogram 2 MS/s 10 MS/s 250 kS/s aggregate (125 kS/s per channel)
Analysis software WincsWare WincsWare HDCV HDCV, TarHeel CV, Demon Pinnacle FSCV software HDCV Framework EZWare
Real-time pseudocolor plot display yes yes yes no yes yes no no
Real-time analysis and control yes (via Application Program Interface) no no no no no no no
Use in Clinical Studies FDA physiologic device exception for OCD Yes80,81,82 no Yes83,84 no no no no

Here we report the results of a series of proof-of-principle experiments aimed at wireless measurement, characterization, and control of neurotransmitter release in healthy non-human primate (NHP), swine, and murine models of DBS using WINCS Harmoni. Specifically, we investigated its ability to simultaneously detect different neurochemical responses evoked by electrical stimulation. The study also validated the capability of WINCS Harmoni to measure stimulation-evoked dopaminergic responses across up to four recording channels and facilitate mathematical characterization of these responses as a function of stimulation parameters. Data were collected using carbon fiber microelectrodes (CFM) implanted within the medial-dorsal striatum of NHP, swine, and rodents. Finally, using a closed-loop paradigm, we tested an example application of the WINCS Harmoni platform for controlling striatal dopaminergic responses through automated modulation of DBS parameters in response to real-time changes in neurochemical activity in vivo.

Results

Simultaneous wireless control of stimulation, neurochemical recordings, and data telemetry

WINCS Harmoni (Fig. 1) provided independent but synchronized stimulation and neurochemical measurements. Two separate rechargeable 6.5 watt-hour lithium-ion batteries in the WINCS Harmoni hardware provided up to 12 hours of continuous stimulation and 7 hours of continuous monitoring of neural activity on a single recording channel. The recording battery life was reduced to three hours when all four recording channels were used simultaneously. An external swappable battery allowed for an additional seven hours of continuous neurochemical detection for a single recording channel.

Figure 1. WINCS Harmoni device.

Figure 1

(A) Photograph of the WINCS Harmoni device; (B) Schematic diagram showing the functional components in WINCS Harmoni, including the neurochemical sensing and stimulation boards, charging components, Bluetooth transceiver, primary microcontroller, and control software in the base station; (C) Image and dimensions of the WINCS Harmoni delta sigma (ΔΣ) analog-to-digital converter (ADC) that enables four channels of simultaneous neurochemical recordings; (D) Typical calibration curves for each of the four neurochemical recording channels in WINCS Harmoni showing a linear relationship between dopamine oxidation current and dopamine concentration.

The integration of the hardware for stimulation and neurochemical recording into a single system enabled the interleaving of stimulation with FSCV recording. As a result, the impact of stimulation artifact on the measurement and characterization of low-amplitude FSCV responses was minimized by controlling where the stimulation artifact appears on the voltammogram, thereby ensuring any stimulation artifact present in the recorded data does not overlap with the signals of interest (Fig. 2). The physical dimensions of the device (84 mm × 130 mm × 47 mm) enabled neurochemical sensing and neurostimulation suitable for behavioral experiments in large animal models. Bench-top characterization tests showed that the stimulator was able to deliver biphasic charge-balanced pulses across up to four channels. Both in vitro and in vivo performance tests in NHP (n = 3), swine (n = 10), and rodents (n = 40) showed that the neurochemical recording module provided four independent channels of neurochemical detection with a signal acquisition bandwidth of 50 kHz and slew rates of up to 1200 V/s for the applied potential.

Figure 2. Effect of stimulation artifact with and without synchronization between neurochemical sensing and stimulation.

Figure 2

(AC) Dopamine detection of dopamine in a rodent undergoing medial forebrain bundle (MFB) deep brain stimulation (DBS) as shown by pseudocolor plots when a device without synchronization is used (left) versus WINCS Harmoni (right). The effect of unsynchronized stimulation artifacts is shown for 60 Hz (A), 90 Hz (B), and 130 Hz (C) stimulation frequencies are shown. (DF) Time-series plot of FSCV data extracted at the dopamine oxidation potential (black dashed line in pseudocolor plot) for recorded dopamine signal without (left) and with (right) stimulation-neurochemical recording synchronization. Stimulations applied at 60 Hz (D), 90 Hz (E), and 130 Hz (F) are shown. (GI) Voltammograms showing the effect of stimulation artifacts on the recorded dopamine signal recorded without (left) and with (right) stimulation-neurochemical recording synchronization for 60 Hz (D), 90 Hz (E), and 130 Hz (F) stimulation respectively. WINCS Harmoni is capable of controlling where the stimulation artifact appears on the voltammogram so it does not interfere with the target measurements as exhibited by artifact free time-series plots (DF).

The Bluetooth digital communication between the remote WINCS Harmoni unit and the base-station computer running the WincsWare software allowed wireless device control and data telemetry for up to 10 meters. In addition, WincsWare allowed real-time visualization of filtered telemetry data from all recording channels (Figure S1), enabling on-line adjustments to the stimulation parameters, recording parameters (e.g., creation of arbitrary waveforms for detection of other neurochemicals), and electrode depth. Raw telemetry data was stored on the base station computer, which enabled both off-line and on-line signal processing, data analysis, and implementation of control strategies using third-party and custom-made software, such as MATLAB (The MathWorks, Inc., Natick, NJ), LabVIEW (National Instruments, Austin, TX), and Python.

In vivo real-time measurement of neurochemical release

WINCS Harmoni was used to quantify the amplitudes of the neurochemical responses corresponding to the release of dopamine, serotonin, and adenosine as identified by their respective peak oxidation and reduction currents occurring at specific applied voltages with respect to a silver/silver-chloride (Ag/AgCl) reference electrode. With a standard triangular waveform40,41 ramping from −0.4 to +1.5 V, the oxidation current peaks occurred at approximately +0.6 V for dopamine, +0.6 V for serotonin, and +1.5 V (and a second oxidation peak at +1.0 V) for adenosine. The reduction peaks occurred at approximately −0.2 V for dopamine, −0.1 V (0.4 V) for serotonin, and +0.25 V (and a second peak at −0.05 V) for adenosine. For serotonin detection a N-shaped waveform is utilized (Figure S2) with an oxidation peak occurring at +0.6 V and a reduction peak at −0.1 V42.

The WINCS Harmoni device measured simultaneous stimulation-evoked dopamine release across four CFMs implanted in the dorsal striatum of anesthetized swine (n = 12) during high frequency electrical stimulation of the substantia nigra pars compacta/ventral tegmental area (SNc/VTA) (Fig. 3). Maximal stimulation-evoked dopaminergic responses were recorded in the anterior lateral border of the caudate along a trajectory that typically ended along the lateral posterior border of the nucleus accumbens (Fig. 3A,B). Additionally, WINCS Harmoni detected spontaneous adenosine release in the striatum of 10 of these swine (Figure S3). Similarly, WINCS Harmoni measured dopamine release in the NHP striatum (n = 3) evoked by SNc/VTA stimulation (Figure S4A,B). Evoked dopamine was observed to increase with both stimulation amplitude and pulse width (Figure S4C,D).

Figure 3. Representative multi-channel measurement of stimulation-evoked neurochemical responses in the swine brain.

Figure 3

(A) A deep brain stimulation (DBS) electrode was implanted within the swine substantia nigra pars compacta/ventral tegmental area (SNc/VTA)56. Reprinted from Brain Research Bulletin, Vol. 49, Bernadette Félix, Marie-Eva Léger, Denise Albe-Fessard, J.-C Marcilloux,O Rampin, J.-P Laplace, A Duclos, F Fort, S Gougis, M Costa, N Duclos, Stereotaxic atlas of the pig brain, 73, 1999, with permission from Elsevier. (B) A representation of four carbon fiber microelectrodes (CFM) for neurochemical recording implanted within the swine striatum (green). The electrode position shown is from co-registration of the pre-operative targeting MRI with a 3D pig atlas70. (C) Schematic representation of the anatomical CFM location with respect to the target locations (B). (D) Pseudocolor plots showing dopamine detection via fast scan cyclic voltammetry (FSCV) from the four CFMs. Dopamine signals were measured using a standard pyramidal FSCV waveform in which the applied voltage was ramped from the holding potential of −0.4 V to the switching potential of +1.45 V and then back to −0.4 V at 400 V/s. (E) Time-series plots showing the current recorded at the dopamine oxidation peak (white dashed line in pseudocolor plot). For each CFM, the voltammogram showing the background subtracted stimulation-evoked dopamine signals recorded at the peak dopamine oxidation current (grey dashed line in the pseudocolor plot) is shown in the inset panel. Subtle differences in the dopamine current peak can be observed at the different electrode locations.

In addition to the measurements in swine and NHP, WINCS Harmoni measured dopamine release in the rodent striatum (n = 40) evoked by MFB stimulation (Fig. 2). In one additional rodent, WINCS Harmoni measured simultaneous dopamine and serotonin release in the striatum and substantia nigra pars reticulata (SNr), respectively, evoked by MFB stimulation (Fig. 4). An additional oxidation was observed at the 1.0 V switching potential for the N-shaped waveform used to measure serotonin (Fig. 4C,D), similar to previously described SNr recordings43. In vivo measurements were compared to flow injection analysis (Figure S5). Immunohistochemistry was performed to confirm the location of the SNr recording electrode (Figure S6).

Figure 4. Recording of multiple neurotransmitters at two different anatomical targets in a rodent model of medial forebrain bundle deep brain stimulation.

Figure 4

(A) Pseudocolor plot showing the detection of stimulation-evoked dopamine in the rodent striatum in response to medial forebrain bundle (MFB) stimulation. Dopamine measurement was performed using fast scan cyclic voltammetry (FSCV) and a standard pyramidal waveform from a −0.4 V holding potential to a +1.45 V switching potential. (B) Pseudocolor plot showing the simultaneous detection of serotonin in the substantia nigra pars reticulata (SNr) using FSCV with a standard N-shaped waveform from +0.2 V to +1.0 V, back down to −0.1 V, and up to +0.2 V. (C) Pseudocolor plot showing an increase in stimulation-evoked serotonin release in the SNr following systemic injection of the selective serotonin reuptake inhibitor (SSRI) fluoxetine. (D) Time-series plot showing the current recorded at the dopamine oxidation peak (black dashed line in pseudocolor plot). The inset panel shows the background subtracted voltammogram recorded at the peak dopamine oxidation current (grey dashed line in the pseudocolor plot). (E) Detection of evoked serotonin in the SNr before and after SSRI administration. Time-series data was extracted from the FSCV data at the black dashed line in panels (B) and (C). (F) Background subtracted cyclic voltammograms for serotonin before and after SSRI administration and extracted at the grey dashed line in panels (B) and (C) respectively.

Mathematical modeling of stimulation-evoked dopamine release

The dopaminergic system in all three animal models exhibited non-linear dopamine kinetics as a function of stimulation amplitude and pulse width. These dopaminergic data measured by WINCS Harmoni were characterized by parametric mathematical models of dopamine release, reuptake, dopamine transfer kinetics (including restricted diffusion), and adsorption/de-sorption at the electrode surface44. These models, trained on stimulation-evoked experimental dopamine responses, were able to accurately describe the non-linear relationships between DBS parameters and stimulation-evoked extracellular dopamine responses for 12 rodents (R2 = 0.90), 4 swine (R2 = 0.96), and 1 NHP (R2 = 0.96) in real-time (Figure S7). This is paramount as control of neurochemical release relies on a well-characterized and consistent relationship with stimulation parameters (e.g., stimulus intensity).

Closed-loop control of stimulation-evoked striatal dopamine release

The neurochemical control strategy based on artificial neural networks (ANN) tested in the rodent model of brain stimulation allowed control of the non-linear dopamine release (R2 = 0.79) by modulating stimulus amplitude and pulse width (Fig. 5A–C). Here, the trained ANN predicted stimulation parameters (i.e., pulse width and amplitude) required to evoke target dopamine responses. Figure 5A shows the raw FSCV data for seven consecutive stimulations in one rodent subject using parameters predicted by the control system. Each response evoked by MFB stimulation is shown in the form of a pseudocolor plot of the FSCV data (top). The pseudocolor plots depict dopamine oxidation (typically occurring at +0.6 V with respect to the Ag/AgCl reference) and reduction (typically at −0.2 V) peak responses. Each response is also shown by a time series (solid black lines, bottom) obtained at the dopamine oxidation voltage. A horizontal dashed gray line shows the target stimulation-evoked dopamine response for each of the seven stimulations. The controller error was determined by the difference between the target and the peak of each time series. As Fig. 5A shows, the experimentally-evoked responses followed the target dopamine responses with small errors. Figure 5B shows the ability of the controller to predict the stimulation parameters required to evoke a repeated pattern of six target peak dopamine responses (each with at least three repetitions) across five different animal subjects. Six target responses ranging from 15% to 60% of the maximal stimulation-evoked dopamine peak at the start of the experiment (typically between 35 and 80 nA) were selected as target maximum stimulation-evoked dopamine responses for testing the controller. Figure 5C shows a regression analysis demonstrating the ability of the controller to predict the stimulation parameters required to evoke the same target dopamine responses (R2 = 0.76) shown in Fig. 5B. Figure 5D shows one example of the ability of the control system to improve prediction error over time through adaptation of the ANN weights and biases. This adaptation allowed the control system to compensate for electrode drift, pH shifts, and other dynamic changes within the brain that affected the amplitude of the stimulation-evoked responses.

Figure 5. Closed-loop control of phasic dopamine release in a rodent model of medial forebrain bundle deep brain stimulation.

Figure 5

(A) Pseudocolor plots (top) and dopamine oxidation current (bottom) showing control of stimulation-evoked dopamine response amplitude over seven dopamine target responses in one rodent model of medial forebrain bundle (MFB) deep brain stimulation (DBS). Pseudocolor plots (top) and time series measurements (bottom) show the dopamine oxidation current measured. A dashed grey line shows the target peak dopamine oxidation currents. Solid black lines show the kinetics of stimulation-evoked dopamine. (B) Dopamine release targets (red squares) and average experimentally evoked dopamine release (black x) evoked with stimulation parameters predicted by the artificial neural network (ANN) controller. Error bars represent standard deviation. Results from five rodents are normalized to the maximum response predicted by the ANN controller. (C) Regression analysis between the target dopamine responses and the peak dopamine responses evoked with parameters predicted by the ANN controller. Pearson’s correlation coefficient was r2 = 0.76. (D) Adaptation of the ANN controller when initiated with an incorrect calibration (n = 1). The error in the experimental response (green or black boxes) with respect to the target maximum dopamine release (red squares) decreased with each stimulation event as the ANN controller adapted.

Discussion

Surgical, pharmacologic, behavioral, cognitive, and neuromodulation therapies have been used to treat distinct neurologic diseases with mixed results. Clinical improvement has been limited at least in part by an incomplete understanding of how specific changes in neural network activity affect behavior. In order to achieve significant advances in patient treatment, the cascade of biomolecular effects that accompany normal and pathological behavior need to be elucidated. While research has shed light on the critical role of neurochemical signaling in the context of normal and pathological brain function, there remains much to understand about the effects of changes in neurochemical signaling in response to disease progression or to treatment. The present study explored the potential for using WINCS Harmoni to address a gap in the understanding of normal and pathologic neurophysiology by analyzing neuromodulation-induced changes in neurochemical dynamics. WINCS Harmoni is an investigational platform for wireless multichannel neurochemical sensing and synchronized stimulation that leverages technology developed for the Wireless Instantaneous Neurotransmitter Concentration Sensing (WINCS) system and the Mayo Investigational Neuromodulation Control System (MINCS)38,39,45. Here, WINCS Harmoni was used to probe neural networks by activating one node within a neural circuit and measuring the downstream neurochemical effects of electrical stimulation. It is important to note that this study was not designed to address neurochemical activity in the context of disease, but rather as a first step toward achieving that goal by testing the capabilities of WINCS Harmoni in healthy animal models of DBS. WINCS Harmoni is based on technologies that can be scaled toward implantable systems. Signal amplification, acquisition, filtering, and digitization is performed within the WINCS Harmoni unit. As such, WINCS Harmoni provides a unique research platform capable of collecting, integrating, and analyzing multi-modality data to study and modulate neural activity in the context of specific disease types, symptoms, and therapeutic interventions, and could be used as an adjunct to drug delivery and neuromodulation therapies to optimize therapeutic effects while minimizing side effects.

Understanding the normal and pathological physiology underlying brain function will require the use of different analysis modalities (e.g., neurochemical sensing, electrophysiological monitoring, functional imaging) to study neural activity across distinct brain regions and the interactions between them. WINCS Harmoni is able to synchronize multiple channels of neurochemical recording with other forms of analysis or therapies (in this case electrical stimulation), facilitating the study of neural activity by ensuring that stimulation artifacts typically observed in in vivo stimulation-evoked neurochemical recordings do not overlap with the signals of interest. Additionally, WINCS Harmoni provides a platform for wireless control and telemetry, thus allowing for seamless real-time interfacing with data analysis software to enable characterization of neurochemical responses. Our results demonstrate that WINCS Harmoni is suitable for detecting changes in neurochemical signaling across different animal models. For this study we focused on dopamine in the dorsal striatum of rodents, swine, and NHP, but the applicability of this device can be generalized to other neurotransmitters/neurochemicals, brain targets, and animal models. For example, WINCS Harmoni was able to simultaneously measure stimulation-evoked dopamine release in the dorsal striatum and serotonin release in the SNr of rodents (see Fig. 4). Additionally, an oxidation signal was observed at the 1.0 V switching potential of the SNr recording (Fig. 4B,C). This signal, agrees with previously characterized simultaneous serotonin and histamine release in the rat SNr following medial forebrain bundle stimulation described by Hashemi et al.43.

The high spatial and temporal resolution of FSCV at a CFMs40,46,47, coupled with the ability of WINCS Harmoni and WincsWare to wirelessly interface in real-time to data analysis software such as MATLAB allowed the measurement and characterization of proximal and distal neurochemical activity at multiple time scales (in the order of milliseconds to minutes) acquired under non-restrictive experimental paradigms. This is important because different diseases and symptoms respond to different therapies on different timescales, which can vary from seconds to months48,49,50,51,52. For example, fast therapeutic responses, such as those found in DBS for treatment of tremor, may be mediated by nearly instantaneous and rapidly reversible mechanisms involving immediate modulation of pathological neural activity53. Slow therapeutic responses, such as those observed in DBS for treatment of dystonia and psychiatric conditions may be mediated, at least in part, by changes brought about through synaptic plasticity and anatomical reorganization54. These different response times suggest that neuromodulation and other forms of therapy act through different mechanisms across different diseases, disease states, and anatomical targets52, likely mediated by short- and long-term changes in neurochemical activity. Additionally, sustaining long-term optimal therapeutic benefits may require frequent adjustments to the therapeutic paradigms (e.g., neuromodulation parameters, medication dose, etc.) in order to accommodate the dynamic neurochemical environment. Thus, therapeutic paradigms in the form of closed-loop interventions that can adapt in response to changes in neural activity will likely improve clinical outcomes and reduce the frequency of outpatient visits. WINCS Harmoni enables the development and implementation of such closed-loop therapies by responding to neurochemical feedback, potentially improving the therapeutic effect by modulating neurochemical levels with high precision compared to standard drug delivery techniques.

In summary, WINCS Harmoni can be used to monitor dopaminergic activity, enable kinetic characterization of stimulation-evoked dopamine (via mathematical models), and automatically adjust stimulation parameters (via artificial neural networks) to achieve target dopaminergic responses. These capabilities can be leveraged to develop adaptive therapies that can compensate for both sudden, as well as slow, physiological changes taking place as a consequence of the condition that is being treated. As demonstrated here, WINCS Harmoni was able to take advantage of closed-loop strategies to control stimulation using real-time in vivo measurement and characterization of neurochemical activity as a feedback signal. We focused our efforts on real-time measurement, characterization, and control of stimulation-evoked dopamine in healthy anesthetized rodents, swine, and NHP. However, future studies using this platform should focus on characterizing cell types (as a function of their neurotransmitters) and differences in neurochemical dynamics in the context of disease state and therapeutic efficacy across different diseases, anatomical targets, and therapeutic interventions. In turn, the results of such studies will further our understanding of the therapeutic mechanisms of neuromodulatory and pharmacologic interventions, ultimately leading to the development of personalized therapies for sustained therapeutic efficacy.

Materials and Methods

Hardware and software for simultaneous stimulation, neurochemical measurement, and data analysis

WINCS Harmoni is a device capable of detecting neurochemical activity at four independent sensors and concurrently applies stimulation to any combination of four electrode contacts. Stimulation can be synchronized with up to four channels of FSCV to control where stimulation artifacts appear in the recorded data and ensure these do not obscure the neurochemical measurements of interest. The WINCS Harmoni electronics are implemented on two multilayer printed circuit boards (PCBs), one for FSCV, control and telemetry, and one for stimulation. Each PCB is powered by its own rechargeable 6.5 watt-hour lithium-ion battery (UBP001, Ultralife Corp., Newark NY) to isolate the electrochemistry and stimulation systems.

A custom analog-to-digital converter (ADC) integrated circuit (Mayo Clinic Special Purpose Processor Development Group, Rochester, Minnesota) allows multi-channel FSCV using custom-designed FSCV voltage waveforms for each channel. Each of the four channels incorporates a three-stage continuous-time delta-sigma (ΔΣ) modulator that produces a digital bit stream at 12.8 Mb per second. A decimation filter in the ΔΣ ADC resolves the digital bit stream into 16-bit samples that are delivered to a microcontroller (LPC1769, NXP Semiconductors, Eindhoven, Netherlands) and thence to a Bluetooth radio (WT41, Bluegiga Technologies, Inc., Espoo, Finland) at a rate of 100,000 samples per second. Wireless data telemetry takes place on the 2.4 GHz frequency band approved by the Federal Communications Commission (FCC).

The stimulator PCB has a separate microcontroller that controls a 16-bit digital-to-analog converter (DAC) (AD5541A, Analog Devices, Inc., Norwood MA) to deliver stimulus pulse sequences. Each stimulus can either be monophasic or biphasic, voltage- or current-regulated, and can be steered to any combination of four electrode contacts. The stimulus amplitude in voltage-regulated mode can be adjusted between 50 mV and 10 V, in 10 mV steps. In current-regulated mode, stimulation may be adjusted between 10 μA and 10 mA, in 10 μA steps. Pulse duration can range between 50 μs and 2 ms. Redundant fault detection circuits, including circuits that measure charge delivered per pulse, protect the subject from unsafe stimulation. Synchronization of stimulation with FSCV acquisition is achieved by specifying a delay (in milliseconds) between the start of each FSCV acquisition and the onset of the first pulse in a stimulus train. The optimal delay for synchronization must be selected based on the desired stimulation parameters and FSCV waveform(s).

The WINCS Harmoni hardware is controlled by a custom software application, WincsWare, running on a Windows PC (Figure S1). Developed in Microsoft® Visual C# (Microsoft Co., Redmond, WA), WincsWare provides a highly configurable user interface for real-time control of stimulation, FSCV, and data visualization. The measured neurochemical data are transmitted wirelessly, via Bluetooth, to a base station Windows® (Microsoft Co., Redmond, WA) computer running WincsWare. The base station provides real-time visualization of filtered telemetry data and storage of raw telemetry data. An application program interface enables applications such as MATLAB to perform on-line data analysis and stimulation control.

Animal subjects

Stimulation-evoked neurochemical responses were measured by surgically implanting DBS electrodes and CFM in 40 female Sprague-Dawley rats weighing 250–350 g, 12 male young adult pigs age 8–12 months weighing 25–35 kg, and 3 male rhesus macaque NHP age 36 months weighing 11–13 kg. Closed-loop control of stimulation-evoked dopamine levels was performed in 12 female Sprague-Dawley rats. All animal studies were performed in vivo with approval of the Institutional Animal Care and Use Committee (IACUC) and following National Institutes of Health (NIH) guidelines for animal research. Rodents were kept in social housing; swine were kept in individual areas. All animals were kept on a 12 hour light/dark cycle at a constant temperature (21 °C) and humidity (45%) and were fed once daily, with ad libitum access to water.

Surgical procedure

Prior to surgery, rodents were sedated with intraperitoneal urethane (1.5 g/kg in a 0.26 g/mL saline solution). Swine were sedated with intramuscular Telazol (6 mg/kg) and xylazine (2 mg/kg), followed by intubation and inhalation anesthesia (1.5–3% isoflurane during electrode implantation and 1.5–2% isoflurane during the rest of the experiment). NHP were sedated with intramuscular ketamine (10 mg/kg) and xylazine (0.5 mg/kg), followed by intubation and inhalation anesthesia. Analgesia was maintained with intramuscular (IM) buprenorphine (0.06 mg/kg for rodents, 0.03 mg/kg for swine) or slow release (SR) buprenorphine (0.06 mg/kg for NHP). A scalp incision (1.5–2.0 cm for rodents, 5–7 cm for swine and NHP) was made to expose the skull, and three trephine burr holes (approximately 3 and 7 mm in diameter for rodent and large animals, respectively) were drilled to allow implantation of stimulating, neurochemical recording, and reference electrodes. A 3 mg intravenous (IV) bolus followed by a 17 mg/hr intravenous drip of vecuronium bromide was administered to swine and NHP during neurochemical recording to prevent stimulation-induced motion artifacts. For swine and NHP, core body temperature (36–38 °C), heart rate (70–110 bpm for swine, 100–130 bpm for NHP), blood pressure (110/80 mmHg for swine, 98 ± 17/54 ± 13 mm Hg for NHP), and blood-oxygen levels (SpO2 of 100%) were continuously monitored to assess the depth of anesthesia and ensure animal welfare.

Stereotactic targeting and electrode implantation

Anesthetized animals were secured in a stereotactic headframe (David Kopf Instruments, Tujunga, CA) for locating the anatomic targets for the DBS and the neurochemical recording electrodes. For rodents, stainless steel bipolar electrodes (250 μm in diameter) with 20 mm long polyimide-coated shaft and a 1000 μm exposed tip (PlasticsOne, Roanoke, VA) were used for stimulation. The stimulating electrodes were implanted into the rodent MFB using a dual micromanipulator system (David Kopf Instruments, Tujunga, CA). The same stereotactic system was used to implant a custom-made CFM into the rat striatum for neurochemical recording via FSCV. The stereotactic coordinates of both the rodent MFB and striatum (Table S1) were obtained relative to bregma according to the Paxinos and Watson atlas of the rat brain55. Neurochemical recording electrodes had an exposed carbon fiber tip, 7 μm in diameter and 50–100 μm long. A Ag/AgCl electrode was implanted into the parenchyma of the contralateral brain hemisphere as a reference for the neurochemical recordings.

Swine and NHP were placed in a custom-made stereotactic headframe (Shon et al., 2010) for MRI-based targeting of the SNc/VTA, STN, and striatal targets. The stereotactic targets and electrode trajectories for swine and NHP were defined using the COMPASS stereotactic targeting platform (COMPASS International Innovations, Rochester, MN) and an anatomical atlas of the swine brain56 and of the NHP brain57. A six-contact DBS electrode, 0.625 mm in diameter, and 0.5 mm contact height with a 0.5 mm inter-contact spacing (NuMed, Hopkinton, NY) was implanted into the SNc/VTA region of swine and STN region of NHP. One NHP was implanted with an additional DBS electrode in the SNc/VTA. Electrode insertion for both DBS and the neurochemical recording electrodes was performed using a computer-controlled microdrive (Alpha Omega Co., Alpharetta, GA).

Measurement of stimulation-evoked neurochemical responses

Subsequent to stereotactic targeting and electrode implantation, the target region (MFB for rodents and SNc/VTA for swine and NHP) was stimulated using a comprehensive range of stimulation parameters (Table S2). Simultaneously, WINCS Harmoni measured the magnitude of stimulation-evoked dopamine release at the CFM. Neurochemical detection of dopamine was performed by first holding the electric potential at the CFM at −0.4 V with respect to the Ag/AgCl reference electrode. Next, the CFM potential was linearly increased to a +1.4 V potential, also known as the “switching potential”, which is higher than the oxidation potential of dopamine. Finally, the CFM potential was linearly decreased back to the holding potential. The potential sweep was performed a rate of 400 V/s and repeated at a frequency of 10 Hz40,58,59. The CFM was held at the resting potential between scans60. Dopamine at the surface of the electrode was oxidized to form dopamine-o-quinone during the positive voltage sweep. The resulting dopamine-o-quinone was then reduced back to dopamine during the negative sweep. FSCV measured the electrical current resulting from the electron transfer, which takes place during these redox reactions between the oxidized and reduced molecules and the microelectrode. Dopamine oxidation currents proportional to the number of molecules undergoing redox reactions allowed estimation of dopamine concentrations using pre-operative and post-operative in vitro calibration of each CFM through flow injection analysis (Fig. 1D)42. The presence of dopamine was confirmed in a small cohort by administering the dopamine reuptake inhibitor nomifensine (20 mg/kg i.p. as the hydrochloride salt; Sigma, St. Louis, MO)61. The presence of serotonin, detected using an N-waveform42, was confirmed by administering the selective serotonin reuptake inhibitor fluoxetine (20 mg/kg i.p. as the hydrochloride salt; Sigma, St. Louis, MO)43.

Multi-channel detection of stimulation-evoked neurochemical responses

To investigate the ability of WINCS Harmoni to conduct quasi-simultaneous neurochemical recording across multiple channels within the same target, as well as within different targets, four parallel CFM were implanted into the swine striatum (n = 10). Electrodes were held in place using a Leksell stereotactic head frame and a “Ben Gun” concentric electrode holder62,63. Electrodes were separated by 2 mm, with one electrode placed on the MRI-identified target for neurochemical recording, one electrode medial to the target trajectory, one electrode lateral, one electrode anterior, and one electrode posterior (Fig. 3). Electrode depth for all recording microelectrodes was controlled by the computer-controlled microdrive or micromanipulator. One rodent was implanted with two neurochemical recording electrodes. The first electrode was implanted in the striatum and the second in the SNr for simultaneous detection of striatal dopamine and SNr serotonin. Stimulation parameters were identical for both multi-channel and single-channel FSCV recordings. FSCV parameters for multi-channel recordings were also identical, except in the case of serotonin recordings, for which an N-waveform was used instead of a triangular waveform43.

Calibration of carbon fiber microelectrodes for neurochemical recording

Redox currents measured during FSCV scans were plotted against the applied potential to generate cyclic voltammograms (Figs 2D–F and 4F for dopamine and serotonin respectively). The cyclic voltammograms were used to identify the unique signatures for each neurotransmitter and distinguish it from other electroactive analytes. Calibration curves defining the relationships between dopamine concentration and corresponding oxidation currents measured experimentally were obtained both pre-operatively and post-operatively using flow injection analysis. Each CFM was placed in a flowing stream of Tris buffer solution while multiple five second boluses of a Tris buffered dopamine solution (e.g., 0.1 μM, 0.5 μM, 1.0 μM) were injected via an electronic loop injector at 6 mL/min. Flow control was performed using a FIAlab 3200 injection system (FIAlab Instruments, Seattle, WA).

Parametric characterization of stimulation-evoked dopaminergic kinetics

The ability of WINCS Harmoni and WincsWare to implement data analysis and control techniques via the MATLAB API was investigated in rodent, swine, and NHP models of DBS by characterizing the stimulation-evoked dopaminergic responses using mathematical models44. For this analysis, stimulation amplitudes and pulse widths leading to the minimal detection (i.e., threshold) and/or saturation of evoked dopamine responses were identified for each subject and used to determine a comprehensive range of stimulation parameters. Stimulation parameters were selected from within this range and applied in random order for either 0.5 or 2.0 seconds to capture system dynamics while eliminating the effects of hysteresis. Each stimulation event was followed by a dopamine stabilization period of either 30 or 300 seconds, depending on the duration of each stimulation event. Stimulation-evoked dopamine responses were first filtered with a 1 KHz third order Butterworth zero-phase shift filter to remove high-frequency noise, and then de-trended (i.e., removal of background currents) to eliminate the effects of capacitive background currents64 (Figure S8A). Next, the stimulation-evoked responses were fit using mathematical compartmental models of release, reuptake, transfer kinetics (e.g., restricted diffusion), and adsorption/de-sorption65,66,67 (Figure S8B,C). The parameters of the models were used to describe the kinetics of dopamine responses as a function of the stimulation parameters.

Real-time feedback control of stimulation-evoked striatal dopamine

The feasibility of using WINCS Harmoni to provide real-time feedback control of striatal dopamine responses was evaluated experimentally in the rodent and swine models of DBS. Here, a strategy to control stimulation-evoked dopaminergic responses was implemented using artificial neural networks (ANN) due to their ability to model dynamic non-linear systems from experimental input/output data68. This predictive model of stimulation-evoked dopaminergic release characterized the inverse relationship between stimulation parameters and evoked dopamine levels by determining the stimulation parameters required to evoke and sustain target in vivo stimulation-evoked striatal dopamine responses (Figure S9). Details on the ANN architecture and training algorithms are presented elsewhere44. Briefly, the predictive controller consisted of a double layer ANN with sigmoidal and linear transfer functions in the input and hidden layers, respectively. The ANN-based controllers had two inputs, two outputs, and seven to nine hidden neurons mapping the relationship between inputs and outputs were used. The inputs to the predictive model corresponded to two mathematical model parameters specifying changes in dopamine concentration. The outputs of the predictive model were the stimulation pulse width and amplitude required to achieve the desired dopaminergic response specified by the inputs. The number of neurons in the hidden layer was optimized for each data set. The weights of the stimulation predictor were adjusted using an adaptive strategy based on the gradient descent method69 to minimize the mean squared error between the expected neurochemical responses and the actual stimulation-evoked neurochemical responses. These ANN controllers were designed, trained, and evaluated in MATLAB, and interfaced to WINCS Harmoni via an application program interface (API) that allowed real-time bi-directional communication between MATLAB and the WINCS Harmoni software, WincsWare.

The controller was evaluated under two testing paradigms. First, a constant peak dopamine response was targeted (Fig. 5A). Target dopamine values were selected by identifying a mid-range dopamine oxidation current between activation and saturation thresholds. Second, regulation of stimulation-evoked dopamine levels between two user-set thresholds of 15% and 60% of the maximal stimulation-evoked dopamine peak was targeted (Fig. 5B). Performance of the feedback controller was evaluated using the mean squared error (MSE) between the desired stimulation-evoked striatal dopamine responses and the experimental responses measured when the DBS target (SNc/VTA or MFB) was stimulated using controller-predicted parameters.

Tissue Preparation and Immunohistochemistry

Recording and stimulating electrode tip positions were identified histologically (Figure S6). Prior to perfusion, electrical lesions (1 mA direct current for 10 seconds) were induced using an optical isolator and programmable pulse generator (Iso-Flex/Master-8; AMPI, Jerusalem, Israel). Rats were perfused with 0.9% saline followed by 4% paraformaldehyde in 0.1 M phosphate buffer (PB). The brains were removed and post-fixed in 4% paraformaldehyde overnight, stored into 25% glycerol in 0.1 M PB solution overnight for cyroprotection. Th e tissue was then blocked, frozen in dry ice and cut in the coronal plane on a sliding microtome. Frozen coronal sections (40 μm thick) were stored in a solution of 0.1 M NaKPO4 and 0.4% Na Azide until use.

Sections of interest were mounted sequentially onto subbed slides and allowed to dry overnight. The slides were then rehydrated in xylenes and a graded series of ethanol diluted in distilled water (100%, 95%, 70%; 1 × 2 minutes each), and then placed into cresyl violet solution for 3 minutes. Sections were rinsed in ascending concentrations of ethanol (25%, 70%; 1 × 4 minutes: one rinse, four minutes per rinse) to remove the excess stain, before placing into a cresyl differentiator (absolute alcohol and glacial acetic acid mixture) for 2 minutes. Afterwards, the sections were dehydrated by passing them through ascending alcohol (95%, 1 × 2 minutes; 100%, 2 × 2 minutes) washes and a set of xylenes washes (3 × 5 minutes). Following dehydration, slides were coverslipped in Eukitt mounting medium (Thermo Fisher Scientific, Waltham, MA).

For immunohistochemical analysis, brain sections were rinsed 3 × 2 minutes in 0.01 M phosphate buffered saline (PBS) containing 0.2% Triton X-1000 (Tx) and pre-treated with 3% hydrogen peroxide in PBS-Tx for 10 minutes. The sections were then rinsed 3 × 2 minutes in PBS-Tx, and then blocked in 10% normal goat serum (Gibco, Thermo Fisher Scientific) for one hour. The sections were incubated with primary antibody solution containing mouse anti-TH (1:4000, Millipore AB152) in 10% normal goat serum overnight at 4 °C with gentle shaking.

Following primary incubation, sections were rinsed 3 × 2 minutes in PBS-Tx, incubated in anti-rabbit secondary antibody coupled to biotin (BA-1000; Vector Laboratories, Burlingame, CA) for one hour, and then incubated for Avidin-Biotin Complex (ABC) amplification (ABC Standard Kit; Vector Laboratories) for an additional hour after a set of PBS-Tx rinses. Following amplification, sections were rinsed for 3 × 2 minutes in 0.1 M PB, and then placed into DAB HRP substrate (Vector Laboratories) for antigen-antibody compound detection. After a last set of 0.1 M PB rinses for 3 × 2 minutes, sections were mounted onto subbed slides and allowed to dry overnight at room temperature. The slides were then dehydrated in a series of ascending ethanol solutions diluted in distilled H2O (70%, 95%, 1 × 2 minutes each; 100%, 2 × 2 minutes) and a set of xylene washes (3 × 5 minutes), and then coverslipped with Eukitt mounting medium in preparation for image analysis.

Imaging Analysis

Coronal brain sections were imaged on a Leica DMR microscope (Wetzlar, Germany) with an Olympus DP70 digital camera (Shinjuku, Tokyo, Japan). Each coronal brain section was imaged using a 10x objective, then stitched together using Adobe Photoshop CC15 (Adobe, San Jose, CA). The corresponding anterior-posterior levels of the coronal brain slices were identified using the Paxinos and Watson brain atlas55.

Additional Information

How to cite this article: Lee, K. H. et al. WINCS Harmoni: Closed-loop dynamic neurochemical control of therapeutic interventions. Sci. Rep. 7, 46675; doi: 10.1038/srep46675 (2017).

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Material

Supplementary Information
srep46675-s1.pdf (2MB, pdf)

Acknowledgments

This work was supported by the National Institutes of Health NINDS (R01 NS75013, R01 NS70872 awards to KHL, and R01 NS084975 award to JLL), and The Grainger Foundation. The authors gratefully acknowledge Bruce Knudsen, Andrea McConico, and Jill L. Anderson for their assistance with animal care and surgery, Drs. Jan T. Hachmann and Grant W. Mallory for their assistance with animal surgery and data collection, Drs. Peter J. Grahn and Aldo A. Mendez, and Anders J. Asp for their assistance with data collection, Megan L. Settell for her assistance with electrode manufacturing, Malcolm Mcintosh, Diane Eaker, Kenneth R. Kressin, Joshua B. Boesche, Sidney V. Whitlock, and their colleagues of the Mayo Clinic Division of Engineering for their contribution to the development and testing of the WINCS Harmoni device and WincsWare software development, Dr. Barry Gilbert, Rick Philpott, James Humble, Christopher Felton, of the Mayo Clinic Special Purpose Processor Development Group for the design of the delta-sigma analog-to-digital converter integrated circuit, and Dr. Penelope Duffy and Dr. Kip Ludwig for providing helpful advice on this manuscript.

Footnotes

K.H.L., K.E.B. and C.D.B. have ongoing patent applications on the use of neurochemical feedback for controlling DBS systems (US 20060195157 A1, US 20120165634 A1).

Author Contributions J.L.L., J.K.T., E.K.R., J.J.B., S.B.P., E.N.N., and H.K.M. performed in vivo experiments and data collection. J.L.L., J.K.T., E.K.R., C.D.B., J.J.B., H.O.P., S.B.P., E.N.N., and H.K.M. analyzed the data. J.H.L. performed histological analysis. K.H.L., J.L.L., and C.D.B. conceived the experiments. J.K.T., S.B.P., and E.N.N. manufactured electrodes. J.L.L., J.K.T., J.J.B., H.O.P., and K.E.B. designed and developed the control software. C.J.K. and K.E.B. designed the hardware. J.K.T., E.K.R., J.H.L., and S.B.P prepared the figures with the help of other authors. K.H.L., J.L.L., J.K.T., J.H.L., C.D.B. and E.K.R. wrote the manuscript, and all authors contributed to its editing. K.E.B. supervised engineering development. K.E.B. and K.H.L. supervised all aspects of the work.

References

  1. Jeanneteau F. et al. A functional variant of the dopamine D3 receptor is associated with risk and age-at-onset of essential tremor. Proc. Natl. Acad. Sci. USA 103, 10753–10758 (2006). [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Horak F. B., Frank J. & Nutt J. Effects of dopamine on postural control in parkinsonian subjects: scaling, set, and tone. J. Neurophysiol. 75, 2380–2396 (1996). [DOI] [PubMed] [Google Scholar]
  3. Foley T. E. & Fleshner M. Neuroplasticity of dopamine circuits after exercise: implications for central fatigue. Neuromolecular Med. 10, 67–80 (2008). [DOI] [PubMed] [Google Scholar]
  4. Lewis S. J. G., Dove A., Robbins T. W., Barker R. A. & Owen A. M. Cognitive Impairments in Early Parkinson’s Disease Are Accompanied by Reductions in Activity in Frontostriatal Neural Circuitry. J. Neurosci. 23, 6351–6356 (2003). [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Parsey R. V. et al. Dopamine D2 receptor availability and amphetamine-induced dopamine release in unipolar depression. Biol. Psychiatry 50, 313–322 (2001). [DOI] [PubMed] [Google Scholar]
  6. Schneier F. R. et al. Dopamine transporters, D2 receptors, and dopamine release in generalized social anxiety disorder. Depress. Anxiety 26, 411–418 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Cummings J. L. Depression and Parkinson’s disease: a review. Am. J. Psychiatry 149, 443–454 (1992). [DOI] [PubMed] [Google Scholar]
  8. Naughton M., Mulrooney J. B. & Leonard B. E. A review of the role of serotonin receptors in psychiatric disorders. Hum. Psychopharmacol. Clin. Exp. 15, 397–415 (2000). [DOI] [PubMed] [Google Scholar]
  9. Organization, W. H. Neurological disorders: public health challenges. (World Health Organization, 2006). [Google Scholar]
  10. Parpura V. et al. Neuromodulation: selected approaches and challenges. J. Neurochem. 124, 436–453 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Benabid A. L., Pollak P., Louveau A., Henry S. & de Rougemont J. Combined (thalamotomy and stimulation) stereotactic surgery of the VIM thalamic nucleus for bilateral Parkinson disease. Appl. Neurophysiol. 50, 344–346 (1987). [DOI] [PubMed] [Google Scholar]
  12. Benabid A. L. et al. Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus. The Lancet 337, 403–406 (1991). [DOI] [PubMed] [Google Scholar]
  13. Blomstedt P. & Hariz M. I. Deep brain stimulation for movement disorders before DBS for movement disorders. Parkinsonism Relat. Disord. 16, 429–433 (2010). [DOI] [PubMed] [Google Scholar]
  14. Youngerman B. E., Chan A. K., Mikell C. B., McKhann G. M. & Sheth S. A. A decade of emerging indications: deep brain stimulation in the United States. J. Neurosurg. 125, 461–471 (2016). [DOI] [PubMed] [Google Scholar]
  15. O’Reardon J. P., Cristancho P. & Peshek A. D. Vagus Nerve Stimulation (VNS) and Treatment of Depression: To the Brainstem and Beyond. Psychiatry Edgmont Pa Townsh. 3, 54–63 (2006). [PMC free article] [PubMed] [Google Scholar]
  16. McIntyre C. C., Savasta M., Kerkerian-Le Goff L. & Vitek J. L. Uncovering the mechanism(s) of action of deep brain stimulation: activation, inhibition, or both. Clin. Neurophysiol. 115, 1239–1248 (2004). [DOI] [PubMed] [Google Scholar]
  17. Shah R. S. et al. Deep Brain Stimulation: Technology at the Cutting Edge. J. Clin. Neurol. 6, 167 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Lee K. H. et al. Dopamine efflux in the rat striatum evoked by electrical stimulation of the subthalamic nucleus: potential mechanism of action in Parkinson’s disease. Eur. J. Neurosci. 23, 1005–1014 (2006). [DOI] [PubMed] [Google Scholar]
  19. Tremblay S. et al. Relationship between transcranial magnetic stimulation measures of intracortical inhibition and spectroscopy measures of GABA and glutamate+ glutamine. J. Neurophysiol. 109, 1343–1349 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Cantello R. et al. Parkinson’s disease rigidity: magnetic motor evoked potentials in a small hand muscle. Neurology 41, 1449–1456 (1991). [DOI] [PubMed] [Google Scholar]
  21. Mills K. R. The natural history of central motor abnormalities in amyotrophic lateral sclerosis. Brain J. Neurol. 126, 2558–2566 (2003). [DOI] [PubMed] [Google Scholar]
  22. Ziemann U., Paulus W. & Rothenberger A. Decreased motor inhibition in Tourette’s disorder: evidence from transcranial magnetic stimulation. Am. J. Psychiatry 154, 1277–1284 (1997). [DOI] [PubMed] [Google Scholar]
  23. Di Lazzaro V. et al. Reduced cerebral cortex inhibition in dystonia: direct evidence in humans. Clin. Neurophysiol. Off. J. Int. Fed. Clin. Neurophysiol. 120, 834–839 (2009). [DOI] [PubMed] [Google Scholar]
  24. Dorr A. E. & Debonnel G. Effect of Vagus Nerve Stimulation on Serotonergic and Noradrenergic Transmission. J. Pharmacol. Exp. Ther. 318, 890–898 (2006). [DOI] [PubMed] [Google Scholar]
  25. Hashimoto T., Elder C. M., Okun M. S., Patrick S. K. & Vitek J. L. Stimulation of the Subthalamic Nucleus Changes the Firing Pattern of Pallidal Neurons. J. Neurosci. 23, 1916–1923 (2003). [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Kita H., Tachibana Y., Nambu A. & Chiken S. Balance of Monosynaptic Excitatory and Disynaptic Inhibitory Responses of the Globus Pallidus Induced after Stimulation of the Subthalamic Nucleus in the Monkey. J. Neurosci. 25, 8611–8619 (2005). [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Miocinovic S. et al. Computational Analysis of Subthalamic Nucleus and Lenticular Fasciculus Activation During Therapeutic Deep Brain Stimulation. J. Neurophysiol. 96, 1569–1580 (2006). [DOI] [PubMed] [Google Scholar]
  28. Benazzouz A. et al. Effect of high-frequency stimulation of the subthalamic nucleus on the neuronal activities of the substantia nigra pars reticulata and ventrolateral nucleus of the thalamus in the rat. Neuroscience 99, 289–295 (2000). [DOI] [PubMed] [Google Scholar]
  29. Maurice N., Thierry A.-M., Glowinski J. & Deniau J.-M. Spontaneous and Evoked Activity of Substantia Nigra Pars Reticulata Neurons during High-Frequency Stimulation of the Subthalamic Nucleus. J. Neurosci. 23, 9929–9936 (2003). [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Smith I. D. & Grace A. A. Role of the subthalamic nucleus in the regulation of nigral dopamine neuron activity. Synap. N. Y. N 12, 287–303 (1992). [DOI] [PubMed] [Google Scholar]
  31. Malone D. A. et al. Deep brain stimulation of the ventral capsule/ventral striatum for treatment-resistant depression. Biol. Psychiatry 65, 267–275 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Mayberg H. S. et al. Deep brain stimulation for treatment-resistant depression. Neuron 45, 651–660 (2005). [DOI] [PubMed] [Google Scholar]
  33. Haslinger B. et al. Differential modulation of subcortical target and cortex during deep brain stimulation. NeuroImage 18, 517–524 (2003). [DOI] [PubMed] [Google Scholar]
  34. Perlmutter J. S. et al. Blood flow responses to deep brain stimulation of thalamus. Neurology 58, 1388–1394 (2002). [DOI] [PubMed] [Google Scholar]
  35. Deuschl G. et al. The pathophysiology of parkinsonian tremor: a review. J. Neurol. 247 Suppl 5, V33–48 (2000). [DOI] [PubMed] [Google Scholar]
  36. Schnitzler A., Münks C., Butz M., Timmermann L. & Gross J. Synchronized brain network associated with essential tremor as revealed by magnetoencephalography. Mov. Disord. Off. J. Mov. Disord. Soc. 24, 1629–1635 (2009). [DOI] [PubMed] [Google Scholar]
  37. Robbins T. W. & Everitt B. J. Functions of dopamine in the dorsal and ventral striatum. Semin. Neurosci. 4, 119–127 (1992). [Google Scholar]
  38. Agnesi F. et al. Wireless Instantaneous Neurotransmitter Concentration System–based amperometric detection of dopamine, adenosine, and glutamate for intraoperative neurochemical monitoring. J. Neurosurg. 111, 701 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  39. Bledsoe J. M. et al. Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry: Technical note. J. Neurosurg. 111, 712 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  40. Robinson D. L., Venton B. J., Heien M. L. A. V. & Wightman R. M. Detecting subsecond dopamine release with fast-scan cyclic voltammetry in vivo. Clin. Chem. 49, 1763–1773 (2003). [DOI] [PubMed] [Google Scholar]
  41. Swamy B. E. K. & Venton B. J. Carbon nanotube-modified microelectrodes for simultaneous detection of dopamine and serotonin in vivo. The Analyst 132, 876–884 (2007). [DOI] [PubMed] [Google Scholar]
  42. Griessenauer C. J. et al. Wireless Instantaneous Neurotransmitter Concentration System: electrochemical monitoring of serotonin using fast-scan cyclic voltammetry–a proof-of-principle study. J. Neurosurg. 113, 656–665 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Hashemi P., Dankoski E. C., Wood K. M., Ambrose R. E. & Wightman R. M. In vivo electrochemical evidence for simultaneous 5-HT and histamine release in the rat substantia nigra pars reticulata following medial forebrain bundle stimulation. J. Neurochem. 118, 749–759 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Trevathan J. K. et al. Computational Modeling of Neurotransmitter Release Evoked by Electrical Stimulation: Nonlinear Approaches to Predicting Stimulation-Evoked Dopamine Release. ACS Chem. Neurosci. 8, 394–410 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Chang S.-Y. et al. Development of the Mayo Investigational Neuromodulation Control System: toward a closed-loop electrochemical feedback system for deep brain stimulation. J. Neurosurg. 119, 1556–1565 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Venton B. J., Troyer K. P. & Wightman R. M. Response Times of Carbon Fiber Microelectrodes to Dynamic Changes in Catecholamine Concentration. Anal. Chem. 74, 539–546 (2002). [DOI] [PubMed] [Google Scholar]
  47. Bucher E. S. & Wightman R. M. Electrochemical Analysis of Neurotransmitters. Annu. Rev. Anal. Chem. 8, 239–261 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  48. Crowell A. L., Garlow S. J., Riva-Posse P. & Mayberg H. S. Characterizing the therapeutic response to deep brain stimulation for treatment-resistant depression: a single center long-term perspective. Front. Integr. Neurosci. 9, 41 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Cury R. G. et al. Effects of deep brain stimulation on pain and other nonmotor symptoms in Parkinson disease. Neurology 83, 1403–1409 (2014). [DOI] [PubMed] [Google Scholar]
  50. Miocinovic S., de Hemptinne C., Qasim S., Ostrem J. L. & Starr P. A. Patterns of Cortical Synchronization in Isolated Dystonia Compared With Parkinson Disease. JAMA Neurol. 72, 1244–1251 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  51. Sachdev P. S. et al. Deep brain stimulation of the antero-medial globus pallidus interna for Tourette syndrome. PloS One 9, e104926 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  52. Servello D., Porta M., Sassi M., Brambilla A. & Robertson M. M. Deep brain stimulation in 18 patients with severe Gilles de la Tourette syndrome refractory to treatment: the surgery and stimulation. J. Neurol. Neurosurg. Psychiatry 79, 136–142 (2008). [DOI] [PubMed] [Google Scholar]
  53. Herrington T. M., Cheng J. J. & Eskandar E. N. Mechanisms of deep brain stimulation. J. Neurophysiol. 115, 19–38 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
  54. Agnesi F., Johnson M. D. & Vitek J. L. Deep brain stimulation: how does it work? Handb. Clin. Neurol. 116, 39–54 (2013). [DOI] [PubMed] [Google Scholar]
  55. Paxinos G. & Watson C. The Rat Brain in Stereotaxic Coordinates: Hard Cover Edition. (Academic Press, 2006). [Google Scholar]
  56. Félix B. et al. Stereotaxic atlas of the pig brain. Brain Res. Bull. 49, 1–137 (1999). [DOI] [PubMed] [Google Scholar]
  57. Saleem K. S. & Logothetis N. K. A Combined MRI and Histology Atlas of the Rhesus Monkey Brain in Stereotaxic Coordinates. (Academic Press, 2012). [Google Scholar]
  58. Budygin E. A., Kilpatrick M. R., Gainetdinov R. R. & Wightman R. M. Correlation between behavior and extracellular dopamine levels in rat striatum: comparison of microdialysis and fast-scan cyclic voltammetry. Neurosci. Lett. 281, 9–12 (2000). [DOI] [PubMed] [Google Scholar]
  59. Garris P. A., Christensen J. R., Rebec G. V. & Wightman R. M. Real-time measurement of electrically evoked extracellular dopamine in the striatum of freely moving rats. J. Neurochem. 68, 152–161 (1997). [DOI] [PubMed] [Google Scholar]
  60. Chang S.-Y., Jay T., Munoz J., Kim I. & Lee K. H. Wireless fast-scan cyclic voltammetry measurement of histamine using WINCS–a proof-of-principle study. The Analyst 137, 2158–2165 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
  61. Jones S. R., Bowman B. P., Kuhn C. M. & Wightman R. M. Development of dopamine neurotransmission and uptake inhibition in the caudate nucleus as measured by fast-cyclic voltammetry. Synapse 24, 305–307 (1996). [DOI] [PubMed] [Google Scholar]
  62. Telkes I., Jimenez-Shahed J., Viswanathan A., Abosch A. & Ince N. F. Prediction of STN-DBS Electrode Implantation Track in Parkinson’s Disease by Using Local Field Potentials. Front. Neurosci. 10, 198 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
  63. Gross R. E., Krack P., Rodriguez-Oroz M. C., Rezai A. R. & Benabid A.-L. Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson’s disease and tremor. Mov. Disord. Off. J. Mov. Disord. Soc. 21 Suppl 14, S259–283 (2006). [DOI] [PubMed] [Google Scholar]
  64. Hayes M. A., Kristensen E. W. & Kuhr W. G. Background-subtraction of fast-scan cyclic staircase voltammetry at protein-modified carbon-fiber electrodes. Biosens. Bioelectron. 13, 1297–1305 (1998). [DOI] [PubMed] [Google Scholar]
  65. Walters S. H., Taylor I. M., Shu Z. & Michael A. C. A Novel Restricted Diffusion Model of Evoked Dopamine. ACS Chem. Neurosci. 5, 776–783 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  66. Walters S. H., Robbins E. M. & Michael A. C. Modeling the Kinetic Diversity of Dopamine in the Dorsal Striatum. ACS Chem. Neurosci.doi: 10.1021/acschemneuro.5b00128 (2015). [DOI] [PubMed] [Google Scholar]
  67. Wightman R. M. et al. Real-time characterization of dopamine overflow and uptake in the rat striatum. Neuroscience 25, 513–523 (1988). [DOI] [PubMed] [Google Scholar]
  68. Lujan J. L. & Crago P. E. Automated optimal coordination of multiple-degree-of-freedom neuromuscular actions in feedforward neuroprostheses. IEEE Trans. Biomed. Eng. 56, 179–187 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  69. Bottou L. In Neural Networks: Tricks of the Trade 421–436 (Springer, 2012). [Google Scholar]
  70. Saikali S. et al. A three-dimensional digital segmented and deformable brain atlas of the domestic pig. J. Neurosci. Methods 192, 102–109 (2010). [DOI] [PubMed] [Google Scholar]
  71. Kimble C. J. et al. Wireless instantaneous neurotransmitter concentration sensing system (WINCS) for intraoperative neurochemical monitoring. In Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE 4856–4859 (IEEE, 2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
  72. Bucher E. S. et al. Flexible Software Platform for Fast-Scan Cyclic Voltammetry Data Acquisition and Analysis. Anal. Chem. 85, 10344–10353 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  73. Takmakov P., McKinney C. J., Carelli R. M. & Wightman R. M. Instrumentation for fast-scan cyclic voltammetry combined with electrophysiology for behavioral experiments in freely moving animals. Rev. Sci. Instrum. 82, 74302 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
  74. Fortin S., Cone J., Ng-Evans S., McCutcheon J. & Roitman M. Sampling phasic dopamine signaling with fast-scan cyclic voltammetry in awake behaving rats. Curr. Protoc. Neurosci. Editor. Board Jacqueline N Crawley Al 70, 7.25.1–7.25.20 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  75. NI PCI-6711 - National Instruments. Available at: http://sine.ni.com/nips/cds/view/p/lang/en/nid/10700. (Accessed: 21st December 2016).
  76. Fast Scan Cyclic Voltammetry Systems | Tethered and Wireless FSCV Systems for Mice or Rats. Available at: http://www.pinnaclet.com/fscv-systems.html. (Accessed: 20th October 2016).
  77. WaveNeuro FSCV Potentiostat System. Pine Research Instrumentation Available at: https://www.pineresearch.com/shop/potentiostats/single-channel/waveneuro-system. (Accessed: 20th October 2016).
  78. Reference 600+ Potentiostat/Galvanostat 5 MHz EIS. Available at: http://www.gamry.com/potentiostats/reference-600-plus/. (Accessed: 20th October 2016).
  79. EZstat-Pro. NuVant Systems Inc. Available at: http://nuvant.com/products/potentiostat_galvanostat/ezstats-series/.
  80. Lee K. H. et al. Emerging techniques for elucidating mechanism of action of Deep Brain Stimulation. Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. IEEE Eng. Med. Biol. Soc. Conf. 2011, 677–680 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
  81. Chang S.-Y. et al. Wireless Fast-Scan Cyclic Voltammetry to Monitor Adenosine in Patients With Essential Tremor During Deep Brain Stimulation. Mayo Clin. Proc. 87, 760–765 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
  82. Bennet K. E. et al. Development of Conductive Boron-Doped Diamond Electrode: A microscopic, Spectroscopic, and Voltammetric Study. Materials 6, 5726–5741 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  83. Kishida K. T. et al. Subsecond dopamine fluctuations in human striatum encode superposed error signals about actual and counterfactual reward. Proc. Natl. Acad. Sci. 113, 200–205 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
  84. Kishida K. T. et al. Sub-Second Dopamine Detection in Human Striatum. PLOS ONE 6, e23291 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information
srep46675-s1.pdf (2MB, pdf)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES