Mapping of intracellular pH in the in vivo rodent heart using hyperpolarized [1‐13C]pyruvate

Angus Z Lau 1,2,, Jack J Miller 2,3, Damian J Tyler 1,2
PMCID: PMC5412837  PMID: 27173806

Abstract

Purpose

To demonstrate the feasibility of mapping intracellular pH within the in vivo rodent heart. Alterations in cardiac acid‐base balance can lead to acute contractile depression and alterations in Ca2+ signaling. The transient reduction in adenosine triphosphate (ATP) consumption and cardiac contractility may be initially beneficial; however, sustained pH changes can be maladaptive, leading to myocardial damage and electrical arrhythmias.

Methods

Spectrally selective radiofrequency (RF) pulses were used to excite the HCO3 and CO2 resonances individually while preserving signal from the injected hyperpolarized [1‐13C]pyruvate. The large flip angle pulses were placed within a three‐dimensional (3D) imaging acquisition, which exploited CA‐mediated label exchange between HCO3 and CO2. Images at 4.5 × 4.5 × 5 mm3 resolution were obtained in the in vivo rodent heart. The technique was evaluated in healthy rodents scanned at baseline and during high cardiac workload induced by dobutamine infusion.

Results

The intracellular pH was measured to be 7.15 ± 0.04 at baseline, and decreased to 6.90 ± 0.06 following 15 min of continuous β‐adrenergic stimulation.

Conclusions

Volumetric maps of intracellular pH can be obtained following an injection of hyperpolarized [1‐13C]pyruvate. The new method is anticipated to enable assessment of stress‐inducible ischemia and potential ventricular arrythmogenic substrates within the ischemic heart. Magn Reson Med 77:1810–1817, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Keywords: hyperpolarization, pH, Cardiac, 13C

INTRODUCTION

The acid‐base balance within the normal functioning heart is tightly regulated 1. Changes in intracellular pH can lead to acute contractile depression, alterations in Ca2+ signaling, and electrical arrhythmias 2. For example, myocardial ischemia and poor coronary perfusion result in increased anaerobic metabolism and production of lactic acid. The ischemic heart benefits from this initial reduction in cardiac contraction, by preserving adenosine triphosphate (ATP) levels for ion channel homeostasis. Sustained ischemia, however, is maladaptive, as inhibition in Na+/K+‐ATPase activity and Na+/Ca2+ exchange lead to calcium overload within the heart.

Few methods exist to noninvasively characterize the intracellular pH (pHi) within the body 3. 31P magnetic resonance spectroscopy (MRS) has long been a gold standard for pHi measurement within the isolated perfused heart 4, 5. This measurement is based on the pH‐dependent chemical shift of the inorganic phosphate (Pi) resonance, but is practically limited to ex vivo studies due to 2,3‐diphosphoglycerate (2,3‐DPG) found in ventricular blood, which contaminates the myocardial Pi signal 6, 7. In vivo measurement using 31P‐MRS of the intracellular pH across the whole heart is possible by a saturation transfer experiment designed to separate the signal contributions from the intracellular, pH‐sensitive, Pi, and the extracellular 2,3‐DPG 8, but low sensitivity limits this approach to whole‐heart assessment with long scan times. Numerous alternative methods exist for monitoring the pH using magnetic resonance, including spectroscopic probes using 1H, 31P, and 19F MRS 9, 10, 11, 12. The sensitivity of these techniques is inherently low, and the resulting chemical shifts are typically small and difficult to resolve at clinical field strengths. The pH‐dependent magnetization transfer between bulk water protons and the endogenous protein amide pool (chemical exchange saturation transfer (CEST)) offers promise, but requires an accurate determination of probe concentration, which is challenging to obtain in vivo 13, 14.

An attractive option for noninvasive pHi measurement is to exploit the CO2/ HCO3 buffering system of the body. These compounds exist in a pH‐dependent steady state within cardiomyocytes, mediated by a rapid exchange catalyzed by carbonic anhydrase (CA) enzymes. Specifically, 13C‐MRS of CO2 and HCO3 concentrations within the heart would enable a ratiometric calculation of pH via the Henderson‐Hasselbalch formula. Unfortunately, this is infeasible using conventional (thermal equilibrium) 13C magnetic resonance, because of limited 13C natural abundance and the inherently low sensitivity of the MR experiment.

Recent developments in hyperpolarized magnetic resonance using the dissolution dynamic nuclear polarization (DNP) method provide transient signal increases in 13C‐labeled substrates relative to their thermal equilibrium polarization in excess of 10000‐fold 15. This molecular imaging modality enables imaging of in vivo metabolic changes in real time, within the initial minute of injection into the body. The injection of hyperpolarized [1‐13C]pyruvate, for example, provides key biochemical information regarding tricarboxylic acid (TCA) cycle flux as well as anaerobic metabolism via observation of [1‐13C]lactate 16, 17, 18. Injection of hyperpolarized 13C‐bicarbonate has previously been used to allow the noninvasive in vivo mapping of extracellular pH by exploiting CA‐mediated exchange within the blood and extracellular space 19. This approach has been used to map the acidic extracellular environment within tumors, which is correlated with prognosis and response to treatment. Developments have been made to extensively characterize and optimize extracellular pH measurements using 13C‐bicarbonate 20, 21. Other approaches to generating 13C‐bicarbonate have also been investigated, using base‐catalyzed hydrolysis in conjunction with biocompatible 13C‐enriched carbonates to reduce toxicity concerns from the presence of Cs+ 22. An interesting hyperpolarized substrate for extracellular pH measurements has been the application of the Good's buffer N‐(2‐acetamido)‐2‐aminoethanesulfonic acid (ACES), which exhibits a pH‐dependent chemical shift 23. The production of acetyl‐CoA from hyperpolarized [1‐13C]pyruvate by pyruvate dehydrogenase (PDH) involves mitochondrial decarboxylation as an initial step before entry into the TCA cycle. This results in the production of intracellular hyperpolarized 13CO2, which is vented from the mitochondrial matrix into the cytoplasm, where a cytosolic CA isoform catalyzes the rapid exchange with H13 CO3. The ratio of these two signals can be used for determination of intracellular pH 24, 25. At physiological pH, the low 13CO2 signal (approximately 10% of myocardial H13 CO3) is often at the limit of detection, which has up until now restricted this technique to whole‐heart assessment 18, 25. Although nonlocalized methods can be useful in physiological states, which affect the heart on a global level, they are insufficient when studying focal regions of ischemia. To use hyperpolarized 13C‐based intracellular pH measurements to identify focal regions of myocardial ischemia, it will be necessary to develop optimized data acquisition methods that increase the measured 13CO2 signal.

The aim of this study was to investigate the feasibility of performing in vivo pHi mapping in the heart, using hyperpolarized 13C MRI. To this aim, we have developed an optimized data acquisition in which spectrally selective radiofrequency (RF) pulses are used to excite the HCO3 and CO2 resonances individually while preserving signal from [1‐13C]pyruvate. A variable timing scheme is used to exploit CA‐mediated label exchange between HCO3 and CO2, which enables the use of large flip angles for a 3D imaging acquisition. Images at 4.5 × 4.5 × 5 mm3 resolution are obtained in the in vivo rodent heart. The technique is evaluated in healthy rodents scanned at baseline and during high cardiac workload induced by dobutamine infusion. The new method is anticipated to enable new cardiovascular imaging examinations in which the severity of stress‐inducible ischemia can be evaluated.

METHODS

All experiments were performed on an Agilent 7 Tesla (T) MRI system (Agilent, Santa Clara, California). All animal investigations conformed to Home Office Guidance on the Operation of the Animals (Scientific Procedures) Act (HMSO) of 1986, to institutional guidelines, and were approved by the University of Oxford Animal Ethics Review Committee.

Animal Handling

Male Wistar rats (n = 5, weight = 500 ± 20 g) were scanned in this study. Two animals were used in initial pilot scans to determine the feasibility of the spectrally selective excitation scheme used for subsequent imaging studies. A further three animals were then scanned in two separate scan sessions consisting of rest and stress conditions to demonstrate the feasibility of the newly developed 3D imaging sequence, described subsequently. Anesthesia was induced at 2.5–3% isoflurane in oxygen and nitrous oxide (4:1, total of 2 L/min). Anesthesia was maintained by means of 2% isoflurane delivered to, and scavenged from, a nose cone during the experiment. A tail vein catheter was placed for intravenous injection of hyperpolarized [1‐13C]pyruvate. When required, a separate tail vein catheter was placed in the contralateral tail vein for delivery of dobutamine during the high cardiac workload experiments, described subsequently. Animals were then placed in a home‐built animal handling system 26. Body temperature was maintained using air heating, and a two‐lead electrocardiogram (ECG) for cardiac gating was obtained using leads placed subcutaneously into the upper forelimbs.

Modulation of Cardiac Workload

Scans were performed in a group of three subjects (n = 3, weight 530 ± 20 g) in separate experiments under either rest or stress conditions. Cardiac workload was increased by continuous dobutamine infusion (concentration 1 mg/mL, dose 100 μg/kg/min, Hameln Pharma Plus GmbH, Germany) into the tail vein using a small animal infusion pump (Harvard Apparatus, Holliston, Massachusetts). The volume of the injection line was filled with dobutamine, and hyperpolarized [1‐13C] pyruvate was administered 15 min after the start of infusion through a separate tail vein catheter. Dobutamine infusion was maintained throughout the 13C scan. The heart rate immediately prior to hyperpolarized [1‐13C]pyruvate injection was 380 ± 20 bpm at rest and 450 ± 10 bpm during stress (P < 0.05, paired t‐test).

Hyperpolarization

[1‐13C]pyruvic acid (14 M neat with 15 mM OX063 trityl radical and 0.8 mM Gd‐DOTA) was hyperpolarized in a prototype DNP hyperpolarizer at 93.979 GHz and 100 mW for 60 min 15. Dissolution was performed at a pressure of 10 bar and a temperature of ∼170 °C in 6 mL of NaOH solution resulting in a pH ∼7 solution of 80 mM [1‐13C]pyruvate. A total of 2 mL of hyperpolarized [1‐13C]pyruvate was injected over 20 s via the tail vein.

MRI Acquisitions

1H images were acquired using a 72‐mm inner diameter dual‐tuned birdcage transmit/receive 1H/13C coil (Rapid Biomedical GmbH, Rimpar, Germany). 13C images were acquired using the same volumetric coil for RF transmission, and a two‐channel surface receive array (two 2 × 4 cm2 elements oriented in the left‐right direction) for signal reception (Rapid Biomedical GmbH, Rimpar, Germany). The surface coil was positioned on the anterior chest wall, and a thermally polarized 5 M 13C urea phantom was used to calibrate the 13C transmitter power before the 13C scans. A 180° pulse was calibrated by finding the power required to null the signal from this phantom. The B1+ for the volume 13C transmit coil was measured in previous phantom experiments using a double‐angle gradient echo (GRE) acquisition, and was found to have a coefficient of variation (SD/mean) of 4% over a cylindrical volume encompassing the sensitive region of the coil (diameter 40 mm, height 40 mm). A volume covering a 40‐mm slab including the heart was used for shimming using a 3D gradient‐echo automated shim routine 27. An axial stack of ECG‐gated, segmented GRE images covering the 40‐mm slab were used for anatomical reference (16 slices, pulse repetition time (TR) 3.3 ms, echo time (TE) 1.3 ms, 128 × 128 matrix, field of view (FOV) 60 × 60 mm2, slice thickness 2.5 mm, 8 averages, 64 segments, bandwidth (BW) 1150 Hz/pixel). ECG‐gated 1H cine imaging was used to assess cardiac function in a single midventricular short‐axis slice in the increased cardiac workload experiments (TR 4.6 ms, TE 1.6 ms, 128 × 128 matrix, FOV 60 × 60 mm2, slice thickness 1.6 mm, 8 averages, BW 1150 Hz/pixel). Function was assessed both at baseline and 5 min following the beginning of dobutamine infusion.

RF Pulse Design

Using the Shinnar Le‐Roux (SLR) algorithm 28, minimum phase, spectrally selective, and spatially nonselective RF pulses were designed to excite either HCO3 (160 ppm, 20° flip angle) or CO2 (124.5 ppm, 70° flip angle) individually, while leaving [1‐13C]pyruvate (170 ppm) unexcited (parameters: duration 10 ms, time bandwidth product 6, 3.0‐ppm passband (95%), 10−5 stopband (6.5 ppm from the center of the passband)). An open‐source RF pulse design toolbox was used to generate these pulses (http://rsl.stanford.edu/research/software.html). The RF pulse for 20° HCO3 excitation is shown in Figure 1a. The corresponding spectral profiles, shown in Figure 1b, are acquired by sweeping the transmitter frequency across a 2000 kHz (26 ppm) range, and obtaining individual free induction decays (FIDs) from a phantom containing thermally polarized, 5M 13C enriched urea (phantom T1 75 ms; scan parameters: TR 400 ms, 8 kHz bandwidth, 2048 points, 256 ms readout, nominal flip angle 20° on resonance, 81 frequency steps). The experimental profiles show good agreement with Bloch simulation, revealing a suppression level of at least 10−3, with the remaining discrepancies likely caused by RF amplifier nonlinearities 29.

Figure 1.

Figure 1

(a) Spectrally selective, minimum phase radiofrequency pulse designed to excite HCO3 (160 ppm) while leaving [1‐13C]pyruvate (170 ppm) unexcited. (b) Experimentally measured spectral profiles using thermally polarized, 5 M 13C urea show good agreement with Bloch simulation (top: real and imaginary response; bottom: magnitude response) with residual errors likely due to RF amplifier nonlinearities.

An ECG‐gated pulse‐and‐acquire sequence was used to demonstrate the signal‐to‐noise ratio (SNR) gain from the large flip angle excitation and to determine the optimal timing window for subsequent imaging experiments of myocardial HCO3 and CO2 (parameters: TR 1 s, 13 kHz bandwidth, 8192 points, 630 ms readout). The sequence alternated between excitation of all metabolites (hard pulse, 50 μs duration, 10°), of HCO3 only (10 ms duration, 20°), or of CO2 only (10 ms duration, 70°).

Figure 2a shows the sum of 1 min of data acquisition obtained following injection of hyperpolarized [1‐13C]pyruvate using the different excitation pulses. These spectra show signals from a nonselective 10° hard pulse excitation in blue, as well as signals from spectrally selective excitation (20° centered on HCO3 in red, 70° centered on CO2 in green). The acquired spectra are localized to the heart as a result of coil placement. Figure 2b shows 1 min of dynamic ECG‐gated spectra using the alternating excitation scheme. It is clear that improved signal‐to‐noise ratios are obtained by using the selective excitation pulse. The higher flip angle selective pulses result in an SNR gain of 1.7‐fold for HCO3 and 3.1‐fold for CO2. Furthermore, despite the large flip angles (70°) delivered to the CO2 resonance, rapid exchange with the HCO3 pool and new production from unaffected pyruvate regenerate this peak for subsequent measurements.

Figure 2.

Figure 2

(a) Summed spectra obtained following injection of [1‐13C]pyruvate are shown using different excitation schemes (blue: nonselective; red: HCO3 only; green: CO2 only). (b) Time courses over 1 min of data acquisition, showing the SNR gain from selective, large flip angle excitation.

3D Imaging Pulse Sequence

Figure 3a shows the 3D ECG‐gated pulse sequence used to obtain axial images of HCO3 and CO2 in the heart. A stack‐of‐spirals trajectory was used for spatial encoding (FOV 60 × 60 × 40 mm3, readout duration 6 ms, in‐plane resolution 4.5 × 4.5 × 5.0 mm2, 8 phase encodes, TE 4.3 ms). The eight phase encodes were acquired in a linear order across k‐space. Sequential CO2 and HCO3 volumes were acquired by switching the excitation pulse used in each block. The TR was varied between the two resonances to allow for regeneration of CO2 from the larger HCO3 resonance (TR 500 ms for CO2, 150 ms for HCO3). The time required to acquire the two metabolic volumes was 6 s.

Figure 3.

Figure 3

(a) 3D sequence used to image HCO3 and CO2 in the heart. Eight phase encodes are required per volume; the TR is varied to allow magnetization transfer between CO2 and HCO3 pools following large flip angle excitation of CO2. Each triangular arrowhead indicates the beginning of a cardiac RR interval. (b) Nonlocalized ECG‐gated spectra show the feasibility of this approach.

Figure 3b shows the feasibility of using this acquisition scheme for 3D imaging. Whole‐heart ECG‐gated spectra were acquired with the readout gradients turned off with the repetition time set to 500 ms for both resonances. The scan was started 10 s after the start of injection. This scan timing was determined from the time course in Figure 2b and was chosen to capture both maximum HCO3 and CO2 signal. High SNR spectra can be obtained for at least 40 s after the start of the scan.

Image Reconstruction and Data Analysis

The spiral trajectory was predicted using a premeasured gradient impulse response function 30. Following Fourier transformation (FFT) along the slab direction, non‐Cartesian k‐space samples were gridded using the nonuniform fast Fourier transform 31, 32. Images were corrected for variable flip angle by dividing each image by sinθ. Linear nearest‐neighbor interpolation using the image magnitude was used to fill in missing HCO3 and CO2 images in the corresponding time series. pHi was estimated using the Henderson‐Hasselbalch equation ( pH=pKa+ log10HCO3/CO2) with pKa = 6.15. pHi maps were masked by including only voxels that reached four standard deviations above the mean magnitude HCO3 noise signal in the final analysis.

A paired, two‐tailed Student's t‐test was used to compare pH values between rest and dobutamine stress conditions. Statistical significance was considered at the P < 0.05 level.

RESULTS

Figure 4 shows dynamic imaging of HCO3 and CO2 using the 3D pHi mapping pulse sequence in a midventricular slice. This set of images directly demonstrates the localization of HCO3 and CO2 signals to the myocardium, with no detectable signal within the blood pool. The images with dashed borders were linearly interpolated from neighboring time points. The initial missing HCO3 time point was linearly extrapolated from the first two frames of the HCO3 time series. The acquisition time for the central kz spiral readout was used as the time point for each image, and this varied between frames resulting from slight variations in heart rate over the course of the scan.

Figure 4.

Figure 4

Dynamic imaging of HCO3 and CO2 in a midventricular slice following injection of HP [1‐13C]pyruvate. The images marked with dashed borders are interpolated from adjacent frames. Images are cropped to a 30 x 30 mm2 FOV.

Figure 5 shows volumetric images of HCO3 and CO2 in the rodent heart, summed over the first 20 s of data acquisition at both rest and during high cardiac workload. The surface coil placement on the chest wall next to the heart and high cardiac PDH flux localize HCO3 and CO2 signals to the heart, demonstrating that any aliasing of HCO3 or CO2 from outside of the FOV is negligible. Spatial pHi maps using the ratio between HCO3 and CO2 images 20 s following the start of injection show pHi = 7.2 ± 0.2 at rest (mean ± SD) across the heart in this subject. In a separate experiment, injection of hyperpolarized [1‐13C]pyruvate during a continuous dobutamine infusion revealed a decrease in pHi to 6.8 ± 0.2 in this subject.

Figure 5.

Figure 5

Volumetric images of HCO3 and CO2 using the 3D sequence. The first 20 s of data are summed. CO2 intensity is increased 10‐fold. Spatial pHi maps reveal pHi = 7.19 ± 0.21 at rest and 6.84 ± 0.17 at stress in this subject. Images are cropped to a 30 x 30 x 30 mm3 FOV.

Figure 6 shows midventricular pHi maps (20 s after the start of injection) in multiple subjects. The HCO3 and CO2 images are localized to the myocardial tissue, as shown by the anatomical segmented GRE images. The pH maps demonstrate a uniform myocardial pHi of 7.15 ± 0.04 (mean ± SD over the group, n = 3) across the whole heart, at rest, consistent with global pHi measurements in rats and pigs 18, 25. Following 15 min of high cardiac workload, pHi decreased to 6.90 ± 0.06 (P < 0.05, paired t‐test). Figure 6b shows the statistical comparison between mean myocardial pHi at rest and during dobutamine stress.

Figure 6.

Figure 6

(a) Intracellular pH measurements obtained using the ratio between HCO3 and CO2 from a mid‐ventricular slice. Images are cropped to a 30x30 mm2 FOV. The scale bar indicates 1 cm. The 13C images are taken from a single time point, 20 seconds after the start of injection. (b) Increased cardiac workload results in decreased apparent pHi in the healthy heart.

DISCUSSION

Significance

The proper functioning of cells relies on tight control of intracellular pH. Despite the vital importance of this physiological parameter, rapid noninvasive mapping of intracellular pH within the in vivo heart is impossible with existing techniques. Here, we build upon the previous use of hyperpolarized substrates 18, 19, 25 and describe a new method that exploits the body's natural HCO3/CO2 buffering system to obtain a spatial three‐dimensional map of the myocardial intracellular pH. The sensitivity of the method is demonstrated by detection of a decrease in pHi following 15 min of high cardiac workload.

It is anticipated that this development will enable new experimental paradigms in which acute, focal alterations in pH can be detected in vivo. Disruption to the acid‐base balance within cells affects enzyme activity, ion channel behavior, Ca2+ handling, and contractile function. Under certain conditions, a decline in cardiac pHi can trigger electrical arrhythmia 2, leading to sudden cardiac death. The ability to create a spatial map of pHi could allow assessment of stress‐inducible ischemia and potential ventricular arrythmogenic substrates within the ischemic heart.

Technical Discussion

The correct use of the Henderson‐Hasselbalch equation for intracellular pH measurement requires that two necessary conditions are satisfied 25. The first of these conditions is that the hyperpolarized acid‐base pair must be in rapid exchange. This condition is satisfied at physiological pH values in which CA enzyme activity is high. If CA activity is low, as may be the case at reduced pH found in ischemia, then 13CO2 and H13 CO3 may not equilibrate on the time scale of the hyperpolarized 13C experiment. The effect of this incomplete equilibration would result in an artefactual low pHi measurement. Previous work has shown agreement between 13C and 31P‐MRS measurements in isolated, perfused hearts subjected to ischemia and subsequent reperfusion 25, which indicates that CA activity is sufficiently high even following an ischemic event.

The second condition is that the acid‐base pair are detected from the same cellular compartment. In rodents, mitochondrial CA activity is low, and mitochondrial CO2 is vented into a cytoplasmic domain with elevated CA activity 24. CO2 efflux from the myocardium into the extracellular space is likely low on the experimental timescale, as the ratio between HCO3 and CO2 reaches a plateau within 5 s in vivo 25. The images indicate that HCO3 and CO2 are confined to the myocardium, which is dominated by the intracellular space. The close agreement of the hyperpolarized 13C pH measurement with the 31P measurement in the perfused heart indicates minimal contamination with the extracellular space 25. CO2 venting from the myocardium into the blood is likely low, as no HCO3 or CO2 signals were visualized within the blood pool here. The absence of any HCO3 and CO2 signal within the blood pool is consistent with dilution into a much larger volume, the fact that mature erythrocytes are anucleate and lack mitochondria, and association of 13CO2 with hemoglobin, which would shorten the T1 and rapidly remove the hyperpolarized signal. It is interesting to contrast the rapid steady state reached in rodents to measurements made in pigs, in which the measured pHi appears to rise over a 20 s period, suggesting a difference between species in the rate at which 13CO2 leaves the cytosolic compartment during the duration of the experiment 18.

Dobutamine, a β1‐adrenergic agonist, is a positive inotrope used clinically to increase cardiac workload as a pharmacologic stress testing agent 33. Continuous dobutamine infusion and increased cardiac workload result in increased PDH and TCA cycle flux, as well as increased glycolysis, leading to the production of excess intracellular lactic acid 34, 35. The delivery of hyperpolarized pyruvate directly probes an increase in the intracellular lactate pool size, as demonstrated by previous studies using hyperpolarized pyruvate in rats 36, 37 and pigs 38, 39. Here, we demonstrate that the increase in glycolysis results in an appreciable intracellular pH change during normoxia, which can also be probed using hyperpolarized [1‐13C]pyruvate, despite the high intracellular buffering capacity and normal perfusion of the myocardium. Similarly, increased cardiac workload reduces intracellular pH in isolated cardiomyocytes during high‐frequency electrical stimulation 40, as well as following β‐adrenergic stimulation using isoprenaline 41.

The optimized acquisition in this study uses spectrally selective imaging of the HCO3 and CO2 resonances to preserve the limited reservoir of hyperpolarized [1‐13C]pyruvate magnetization 18, 42, 43, 44, 45, 46, 47. As the method is based on the ratio between HCO3 and CO2 signals, the measured pH is independent of the concentration of pyruvate or its downstream metabolites. The main requirement is that the PDH flux is high enough to enable the detection of CO2 and HCO3 within the cell. One limitation of this approach is that the arrival of pyruvate into the heart is not monitored. Although pyruvate concentration is not required for pH determination, imaging the arrival of hyperpolarized pyruvate at the heart would allow a simultaneous measurement of cardiac PDH flux, which would be useful to assess tissue viability 18. Pyruvate images could also be used to determine the optimal time to acquire HCO3 and CO2 images, which would be useful in a heterogeneous subject group in which the arterial input function is expected to be variable. Alternatively, co‐polarization of metabolically inert 13C urea alongside [1‐13C]pyruvate could be used to obtain the arrival time without disturbing the hyperpolarized pyruvate magnetization 48, 49.

The limiting factor for accurate pHi determination is the relatively low SNR of the CO2 signal specifically, which is 10% of the HCO3 signal at physiological pH levels. This is consistent with an error propagation analysis of the Henderson‐Hasselbalch equation, which leads to σpH2=1/SNRbic2+1/SNRCO22, where σX denotes the standard deviation of X, and SNRX=X/σX denotes the signal‐to‐noise ratio. The SNR of the CO2 is typically ∼5 in the in vivo experiments shown here, which is consistent with the single subject standard deviation reported in Figure 5. A 70° flip angle was used to excite CO2; this angle was chosen to improve SNR while avoiding excitation by flip angles above 90° due to B1+ inhomogeneity, which would decrease the CO2 signal. This is a reasonable trade‐off, as the transverse magnetization created by 70° excitations is 94% that of a 90° excitation.

The CO2 SNR may further be improved by shortening the duration of the CO2 excitation. Specifically, the 10 ms pulse used for excitation of HCO3 (170 ppm) was designed to avoid excitation of [1‐13C]pyruvate (160 ppm). CO2, which is positioned at 124.5 ppm, is three times further away in chemical shift, and a shortened pulse (∼3.5 ms) would reduce the effective echo time and reduce T2*‐related dephasing across the volume. Although this could potentially improve SNR, the difference in echo time would need to be compensated by T2* mapping within the heart. This could be done using multiecho 1H images, and converting the T2* values to 13C via multiplication by γ1H13C ≈ 4.

Currently, the validation of noninvasive methods for intracellular pH mapping within the myocardium is challenging. The gold standard for noninvasive intracellular pH measurement, 31P‐MRS, suffers from contamination of the pH‐sensitive Pi resonance with 2,3‐diphosphoglycerate (2,3‐DPG) found in the ventricular blood. It is possible to perform a saturation transfer experiment to remove the contribution from 2,3‐DPG, but this method remains limited to a whole‐heart measurement with long scan time due to limited SNR 8. The 13C and 31P‐based measurements agree in isolated, perfused rat hearts in which blood is not present 25. Invasive measurements using either blood replacement 6 or open‐chest techniques 7 may be of value for correlation with the noninvasive hyperpolarized 13C measurements described here.

Clinical Translation

The use of hyperpolarized 13C substrates to study human heart disease is rapidly approaching the clinic. The first application of hyperpolarized magnetic resonance in humans at the University of California, San Francisco, demonstrated the potential of the technique to stage prostate cancer and assess the response to treatment 50. New hyperpolarizer designs that produce sterile, clinical‐grade tracers for human use are now available 51. Hyperpolarized pyruvate is approved for use in physiological studies that will be centered on assessing metabolic conversion within the heart into lactate, alanine, and bicarbonate as sensitive markers of cellular viability and metabolic state. Therefore, intracellular pH mapping, using the metabolic products of hyperpolarized [1‐13C]pyruvate, has a direct path for clinical translation.

CONCLUSIONS

An optimized sequence for mapping intracellular pH within the rodent heart in under a minute is proposed. Following an injection of hyperpolarized [1‐13C]pyruvate, mitochondrial decarboxylation results in cytosolic CO2 and HCO3. Spectrally selective excitation is combined with a rapid 3D imaging readout, and the rapid regeneration of CO2 due to carbonic anhydrase‐mediated exchange is used to obtain whole‐heart intracellular pH maps in vivo. The intracellular pH was measured to be 7.15 ± 0.04 at baseline, and decreased to 6.90 ± 0.06 following 15 min of continuous β‐adrenergic stimulation. The new method is anticipated to enable assessment of stress‐inducible ischemia and potential ventricular arrhythmogenic substrates within the ischemic heart.

ACKNOWLEDGMENTS

The research was supported by the National Institute for Health Research (NIHR) Oxford Biomedical Research Centre Programme, British Heart Foundation Fellowship (FS/10/002/28078, FS/14/17/30634), British Heart Foundation Programme Grant (RG/11/9/28921), and EPSRC Doctoral Training Centre and Prize Fellowship (EP/M508111/1) grants.

REFERENCES

  • 1. Vaughan‐Jones RD, Spitzer KW, Swietach P. Intracellular pH regulation in heart. J Mol Cell Cardiol 2009;46:318–331. [DOI] [PubMed] [Google Scholar]
  • 2. Orchard CH, Cingolani HE. Acidosis and arrhythmias in cardiac muscle. Cardiovasc Res 1994;28:1312–1319. [DOI] [PubMed] [Google Scholar]
  • 3. Frohlich O, Wallert MA. Methods of measuring intracellular pH in the heart. Cardiovasc Res 1995;29:194–202. [DOI] [PubMed] [Google Scholar]
  • 4. Hoult DI, Busby SJ, Gadian DG, Radda GK, Richards RE, Seeley PJ. Observation of tissue metabolites using 31P nuclear magnetic resonance. Nature 1974;252:285–287. [DOI] [PubMed] [Google Scholar]
  • 5. Bailey IA, Williams SR, Radda GK, Gadian DG. Activity of phosphorylase in total global ischaemia in the rat heart. A phosphorus‐31 nuclear‐magnetic‐resonance study. Biochem J 1981;196:171–178. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Katz LA, Swain JA, Portman MA, Balaban RS. Intracellular pH and inorganic phosphate content of heart in vivo: a 31P‐NMR study. Am J Physiol 1988;255:H189–H196. [DOI] [PubMed] [Google Scholar]
  • 7. Brindle KM, Rajagopalan B, Williams DS, Detre JA, Simplaceanu E, Ho C, Radda GK. 31P NMR measurements of myocardial pH in vivo. Biochem Biophys Res Comm 1988;151:70–77. [DOI] [PubMed] [Google Scholar]
  • 8. Blamire AM, Rajagopalan B, Radda GK. Measurement of myocardial pH by saturation transfer in man. Magn Reson Med 1999;41:198–203. [DOI] [PubMed] [Google Scholar]
  • 9. van Sluis R, Bhujwalla ZM, Raghunand N, Ballesteros P, Alvarez J, Cerdan S, Galons JP, Gillies RJ. In vivo imaging of extracellular pH using 1H MRSI. Magn Reson Med 1999;41:743–750. [DOI] [PubMed] [Google Scholar]
  • 10. Vermathen P, Capizzano AA, Maudsley AA. Administration and (1)H MRS detection of histidine in human brain: application to in vivo pH measurement. Magn Reson Med 2000;43:665–675. [DOI] [PubMed] [Google Scholar]
  • 11. Gillies RJ, Liu Z, Bhujwalla Z. 31P‐MRS measurements of extracellular pH of tumors using 3‐aminopropylphosphonate. Am J Physiol 1994;267:C195–C203. [DOI] [PubMed] [Google Scholar]
  • 12. Mason RP. Transmembrane pH gradients in vivo: measurements using fluorinated vitamin B6 derivatives. Curr Med Chem 1999;6:481–499. [PubMed] [Google Scholar]
  • 13. Ward KM, Balaban RS. Determination of pH using water protons and chemical exchange dependent saturation transfer (CEST). Magn Reson Med 2000;44:799–802. [DOI] [PubMed] [Google Scholar]
  • 14. Zhou J, Payen JF, Wilson DA, Traystman RJ, van Zijl PC. Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nat Med 2003;9:1085–1090. [DOI] [PubMed] [Google Scholar]
  • 15. Ardenkjaer‐Larsen JH, Fridlund B, Gram A, Hansson G, Hansson L, Lerche MH, Servin R, Thaning M, Golman K. Increase in signal‐to‐noise ratio of > 10,000 times in liquid‐state NMR. Proc Natl Acad Sci U S A 2003;100:10158–10163. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Golman K, Petersson JS, Magnusson P, Johansson E, Akeson P, Chai C‐M, Hansson G, Månsson S. Cardiac metabolism measured noninvasively by hyperpolarized 13C MRI. Magn Reson Med 2008;59:1005–1013. [DOI] [PubMed] [Google Scholar]
  • 17. Schroeder MA, Cochlin LE, Heather LC, Clarke K, Radda GK, Tyler DJ. In vivo assessment of pyruvate dehydrogenase flux in the heart using hyperpolarized carbon‐13 magnetic resonance. Proc Natl Acad Sci U S A 2008;105:12051–12056. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Chen AP, Hurd RE, Schroeder MA, Lau AZ, Gu YP, Lam WW, Barry J, Tropp J, Cunningham CH. Simultaneous investigation of cardiac pyruvate dehydrogenase flux, Krebs cycle metabolism and pH, using hyperpolarized [1,2‐(13)C2]pyruvate in vivo. NMR Biomed 2012;25:305–311. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Gallagher FA, Kettunen MI, Day SE, et al. Magnetic resonance imaging of pH in vivo using hyperpolarized 13C‐labelled bicarbonate. Nature 2008;453:940–943. [DOI] [PubMed] [Google Scholar]
  • 20. Scholz DJ, Janich MA, Kollisch U, Schulte RF, Ardenkjaer‐Larsen JH, Frank A, Haase A, Schwaiger M, Menzel MI. Quantified pH imaging with hyperpolarized (13) C‐bicarbonate. Magn Reson Med 2015;73:2274–2282. [DOI] [PubMed] [Google Scholar]
  • 21. Scholz DJ, Otto AM, Hintermair J, et al. Parameterization of hyperpolarized (13)C‐bicarbonate‐dissolution dynamic nuclear polarization. MAGMA 2015;28:591–598. [DOI] [PubMed] [Google Scholar]
  • 22. Korenchan DE, Flavell RR, Baligand C, Sriram R, Neumann K, Sukumar S, VanBrocklin H, Vigneron DB, Wilson DM, Kurhanewicz J. Dynamic nuclear polarization of biocompatible (13)C‐enriched carbonates for in vivo pH imaging. Chem Commun (Camb) 2016;52:3030–3033. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Flavell RR, von Morze C, Blecha JE, et al. Application of Good's buffers to pH imaging using hyperpolarized (13)C MRI. Chem Commun (Camb) 2015;51:14119–14122. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Schroeder MA, Ali MA, Hulikova A, Supuran CT, Clarke K, Vaughan‐Jones RD, Tyler DJ, Swietach P. Extramitochondrial domain rich in carbonic anhydrase activity improves myocardial energetics. Proc Natl Acad Sci U S A 2013;110:E958–E967. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25. Schroeder MA, Swietach P, Atherton HJ, Gallagher FA, Lee P, Radda GK, Clarke K, Tyler DJ. Measuring intracellular pH in the heart using hyperpolarized carbon dioxide and bicarbonate: a 13C and 31P magnetic resonance spectroscopy study. Cardiovasc Res 2010;86:82–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26. Cassidy PJ, Schneider JE, Grieve SM, Lygate CA, Tyler DJ, Neubauer S, Clarke K. An animal handling system for small animals in vivo MR. Proc ISMRM 2005;13:488. [Google Scholar]
  • 27. Schneider JE, Barnes H, Neubauer S, Jezzard P. Automated‐shim approach to facilitate 1H‐MRS in mouse hearts in vivo. In Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawaii, USA, 2009. Abstract 1782.
  • 28. Pauly J, Le Roux P, Nishimura D, Macovski A. Parameter relations for the Shinnar‐Le Roux selective excitation pulse design algorithm [NMR imaging]. IEEE Trans Med Imaging 1991;10:53–65. [DOI] [PubMed] [Google Scholar]
  • 29. Chan F, Pauly J, Macovski A. Effects of RF amplifier distortion on selective excitation and their correction by prewarping. Magn Reson Med 1992;23:224–238. [DOI] [PubMed] [Google Scholar]
  • 30. Vannesjo SJ, Haeberlin M, Kasper L, Pavan M, Wilm BJ, Barmet C, Pruessmann KP. Gradient system characterization by impulse response measurements with a dynamic field camera. Magn Reson Med 2013;69:583–593. [DOI] [PubMed] [Google Scholar]
  • 31. Fessler JA, Sutton BP. Nonuniform fast Fourier transforms using min‐max interpolation. IEEE Trans Sig Process 2003;51:560–574. [Google Scholar]
  • 32. Zwart NR, Johnson KO, Pipe JG. Efficient sample density estimation by combining gridding and an optimized kernel. Magn Reson Med 2012;67:701–710. [DOI] [PubMed] [Google Scholar]
  • 33. Tuttle RR, Mills J. Dobutamine: development of a new catecholamine to selectively increase cardiac contractility. Circ Res 1975;36:185–196. [DOI] [PubMed] [Google Scholar]
  • 34. Sharma N, Okere IC, Brunengraber DZ, McElfresh TA, King KL, Sterk JP, Huang H, Chandler MP, Stanley WC. Regulation of pyruvate dehydrogenase activity and citric acid cycle intermediates during high cardiac power generation. J Physiol 2005;562:593–603. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35. O'Donnell JM, Kudej RK, LaNoue KF, Vatner SF, Lewandowski ED. Limited transfer of cytosolic NADH into mitochondria at high cardiac workload. Am J Physiol Heart Circ Physiol 2004;286:H2237–H2242. [DOI] [PubMed] [Google Scholar]
  • 36. Schroeder MA, Atherton HJ, Dodd MS, Lee P, Cochlin LE, Radda GK, Clarke K, Tyler DJ. The cycling of acetyl‐coenzyme A through acetylcarnitine buffers cardiac substrate supply: a hyperpolarized 13C magnetic resonance study. Circ Cardiovasc Imaging 2012;5:201–209. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Josan S, Park JM, Hurd R, Yen YF, Pfefferbaum A, Spielman D, Mayer D. In vivo investigation of cardiac metabolism in the rat using MRS of hyperpolarized [1‐13C] and [2‐13C]pyruvate. NMR Biomed 2013;26:1680–1687. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Menichetti L, Frijia F, Flori A, et al. Assessment of real‐time myocardial uptake and enzymatic conversion of hyperpolarized [1‐(13) C]pyruvate in pigs using slice selective magnetic resonance spectroscopy. Contrast Media Mol Imaging 2012;7:85–94. [DOI] [PubMed] [Google Scholar]
  • 39. Chen AP, Lau AZ, Gu Y, Schroeder MA, Barry J, Cunningham CH. Investigation of cardiac malate‐aspartate shuttle at high workload using hyperpolarized [1,2‐13C2]pyruvate. In Proceedings of the 21st Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. Abstract 4511.
  • 40. Bountra C, Kaila K, Vaughan‐Jones RD. Effect of repetitive activity upon intracellular pH, sodium and contraction in sheep cardiac Purkinje fibres. J Physiol 1988;398:341–360. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41. Shida S, Nakaya H, Matsumoto S, Kanno M. Beta 1 adrenoceptor mediated decrease in pHi in quiescent ventricular myocardium. Cardiovasc Res 1994;28:112–118. [DOI] [PubMed] [Google Scholar]
  • 42. Chen WC, Teo XQ, Lee MY, Radda GK, Lee P. Robust hyperpolarized (13)C metabolic imaging with selective non‐excitation of pyruvate (SNEP). NMR Biomed 2015;28:1021–1030. [DOI] [PubMed] [Google Scholar]
  • 43. Chen AP, Cunningham CH. Single voxel localization for dynamic hyperpolarized (13)C MR spectroscopy. J Magn Reson 2015;258:81–85. [DOI] [PubMed] [Google Scholar]
  • 44. Lau AZ, Chen AP, Ghugre NR, Ramanan V, Lam WW, Connelly KA, Wright GA, Cunningham CH. Rapid multislice imaging of hyperpolarized (13)C pyruvate and bicarbonate in the heart. Magn Reson Med 2010;64:1323–1331. [DOI] [PubMed] [Google Scholar]
  • 45. Lau AZ, Chen AP, Hurd RE, Cunningham CH. Spectral‐spatial excitation for rapid imaging of DNP compounds. NMR Biomed 2011;24:988–996. [DOI] [PubMed] [Google Scholar]
  • 46. Miller JJ, Lau AZ, Teh I, Schneider JE, Kinchesh P, Smart S, Ball V, Sibson NR, Tyler DJ. Robust and high resolution hyperpolarized metabolic imaging of the rat heart at 7 T with 3D spectral‐spatial EPI. Magn Reson Med 2016;75:1515–1524. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47. Larson PEZ, Kerr AB, Chen AP, Lustig MS, Zierhut ML, Hu S, Cunningham CH, Pauly JM, Kurhanewicz J, Vigneron DB. Multiband excitation pulses for hyperpolarized 13C dynamic chemical‐shift imaging. J Magn Reson 2008;194:121–127. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48. Lau AZ, Miller JJ, Robson MD, Tyler DJ. Cardiac perfusion imaging using hyperpolarized 13C urea using flow sensitizing gradients. Magn Reson Med 2016;75:1474–1483. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Lau AZ, Miller JJ, Robson MD, Tyler DJ. Simultaneous assessment of cardiac metabolism and perfusion using copolarized [1‐ C]pyruvate and C‐urea. Magn Reson Med 2017;77:151–158. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50. Nelson SJ, Kurhanewicz J, Vigneron DB, et al. Metabolic imaging of patients with prostate cancer using hyperpolarized [1‐13C]Pyruvate. Sci Transl Med 2013;5:198ra108. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51. Ardenkjaer‐Larsen JH, Leach AM, Clarke N, Urbahn J, Anderson D, Skloss TW. Dynamic nuclear polarization polarizer for sterile use intent. NMR Biomed 2011;24:927–932. [DOI] [PubMed] [Google Scholar]

Articles from Magnetic Resonance in Medicine are provided here courtesy of Wiley

RESOURCES