Abstract
The chemistry of F2 and its derivatives are amenable to facile aliphatic or aromatic substitution, as well as electrophilic addition. The main limitation in the use of [18F]F2 for radiopharmaceutical synthesis is the low specific activity achieved by the traditional methods of production. The highest specific activities, 55 GBq/μmol, for [18F]F2 have been achieved so far by using electrical discharge in the post‐target production of [18F]F2 gas from [18F]CH3F. We demonstrate that [18F]F2 is produced by illuminating a gas mixture of neon/F2/[18F]CH3F with vacuum ultraviolet photons generated by an excimer laser. We tested several illumination chambers and production conditions. The effects of the initial amount of [18F]F‐, amount of carrier F2, and number of 193‐nm laser pulses at constant power were evaluated regarding radiochemical yield and specific activity. The specific activity attained for [18F]F2‐derived [18F]NFSi was 10.3 ± 0.9 GBq/μmol, and the average radiochemical yield over a wide range of conditions was 6.7% from [18F]F‐. The production can be improved by optimization of the synthesis device and procedures. The use of a commercially available excimer laser and the simplicity of the process can make this method relatively easy for adaptation in radiochemistry laboratories.
Keywords: [18F]F2, [18F]NFSi, electrophilic 18F, excimer laser, fluorine‐18, PET, radiochemistry, specific activity
1. INTRODUCTION
Positron emission tomography (PET) is a diagnostic technique, which allows the study of biological processes in living subjects. 18F is the most commonly used radionuclide in the production of PET tracers and can be introduced into a molecule by nucleophilic or electrophilic methods. Nowadays, most 18F‐labelled tracers are made by a nucleophilic approach because of the ready availability of nucleophilic [18F]F‐, which is produced in high specific activity (SA) by the 18O(p,n)18F nuclear reaction in an 18O‐enriched water target. In contrast, electrophilic [18F]F2 is only produced by F2 carrier‐added methods, which lower the SA. Despite this limitation, some tracers such as [18F]CFT1 and [18F]EF5 are made2 by electrophilic fluorination.
Electrophilic fluorination is a fast way of introducing a fluorine atom into organic molecules. While F2 can be directly used for electrophilic substitution, it can also be easily transformed into milder fluorination reagents. Presently, there are various electrophilic 18F labelling reagents with different reactivities, which can be used for PET tracer production. These include [18F]XeF2,3 [18F]CH3COOF,4 [18F]‐N‐fluorobenzenesulfonimide ([18F]NFSi),5 [18F]N‐fluoropyridinium salts,6 and [18F]Selectfluor bis(triflate).7 The use of F2 and its derivatives allows aliphatic or aromatic substitution, as well as electrophilic addition to be performed. The main limitation in the use of [18F]F2 for tracer synthesis is the low SA achieved by the traditional methods of production. There are 2 practically useful approaches for the cyclotron production of [18F]F2 gas: 20Ne(d,α)18F and 18O(p,n)18F, which lead to SAs of 0.1 GBq/μmol8 and 1.3 GBq/μmol,9 respectively. In 1997, Bergman and Solin reported a method for the post‐target production of [18F]F2 gas from [18F]CH3F. They applied a high‐voltage discharge to perform the 19F/18F isotopic exchange and obtained [18F]F2 with a SA of 55 GBq/μmol.10 Since that time, this method has been used at Turku PET Centre in the production of different tracers such as 6‐[18F]fluoro‐DOPA, [18F]CFT, and [18F]EF511 for clinical use. However, the discharge method has its limitations. The high‐voltage discharge (25‐30 kV) creates a harsh environment in the reaction chamber resulting in the consumption of F2 gas. Furthermore, this method requires specialized equipment, which can be difficult to install.
We propose that by using a gentler source of excitation, such as vacuum ultraviolet (VUV) photons generated by an excimer laser, we can reduce the amount of carrier F2 gas needed for the [18F]F2 production and this might, in turn, result in higher SA. Since the bond‐dissociation energies for fluoromethane (CH3F) to tetra‐fluoromethane (which are present in the chamber during isotopic exchange) are in a range of 260 to 219 nm,12 the energy of the ArF excimer laser (193 nm) is sufficient to break the C–F bond. Herein, we report the proof‐of‐principle for the VUV illumination method for the production of [18F]F2.
2. EXPERIMENTAL
2.1. General
All organic solvents were high‐performance liquid chromatography (HPLC) grade and purchased from Sigma‐Aldrich (Steinheim, Germany). Potassium carbonate was also purchased from Sigma‐Aldrich. Kryptofix 222 [4,7,13,16,21,24‐hexaoxa‐1,10‐diazabicyclo[8.8.8]hexacosane] was purchased from Merck KGaA (Darmstadt, Germany). [18F]‐N‐fluorobenzenesulfonimide was used as a model compound for the identification of the [18F]F2 synthesized during the experiment due to its straightforward preparation (Figure 1) and identification (Figure 2). Sodium dibenzenesulfonimide ([18F]NFSi precursor) was supplied by Prof Gouverneur's Group (University of Oxford, Oxford, United Kingdom).
Figure 1.

Synthesis of [18F]F2 from [18F]F‐ aq and subsequent synthesis of [18F]‐N‐fluorobenzenesulfonimide. Yields 1 to 3 represent the respective synthesis step yields. n and m denote the respective molar amounts. As described in Bergman and Solin10, the exchange process can be simulated by a Monte Carlo model. When the molar amount of carrier F2 gas is in large excess compared to that of [18F]CH3F (ie, n > >m) and assuming that all the bonds of the molecules in the gas mixture are broken, the exchange reaction will produce (n‐3 m) moles of [18F]F2
Figure 2.

Analytical high‐performance liquid chromatography chromatograms of [18F]‐N‐fluorobenzenesulfonimide. Red color denotes radioactivity, and black shows the UV signal
18O‐enriched water for the production of 18F was purchased from Rotem Industries Ltd (Arava, Israel). Gases were supplied by AGA, Linde group (Espoo, Finland).
For HPLC analysis, a Merck Hitachi LaChrom 7000 system with Hitachi D‐7000 HPLC System Manager software (version 3.1.1) was used. Analyses were performed using a Waters Atlantis dC18, 3.9 × 150‐mm column (Waters Corp, Milford, Massachusetts) with a gradient of H2O and MeCN starting from 95% water to 20% water over 10 minutes with a flow of 1.5 mL/min. A wavelength of 254 nm was used for the UV detector. Radioactivity was detected with a NaI(Tl) scintillator detector (2 × 2 in; Bicron, Newbury, Ohio) placed on the HPLC column outlet.
The illumination chambers were custom made to our specifications by Finnish Special Glass Oy (Espoo, Finland). The TiO2 reflective paint (BC‐620) was purchased from Saint‐Gobain Crystals (Nemours, France).
The gas chromatography column (id 0.8 cm, length 30 cm) was filled with HayeSep Q 60‐80 mesh (Sigma‐Aldrich, Steinheim, Germany).
2.2. Laser
The ArF ExciStar XS laser (Coherent, Gottingen, Germany) was installed outside the hot cell. A hole was drilled in the hot cell wall, and a metal tube was used to transfer the laser beam in a helium atmosphere to the illumination chamber (Figure 3). The laser is operated in pulse mode, with 15 000, 30 000 or 60 000 pulses being used, depending on the experiment. The repetition rate (200 Hz) and energy (11‐12 mJ/pulse) were kept constant for all the experiments.
Figure 3.

A, Schematic diagram of the apparatus for converting [18F]CH3F to [18F]F2 using the vacuum ultraviolet laser. B, A photograph depicting the setup of the apparatus in the laboratory, from left to right; hot cell containing synthesis device, laser housed in adjacent fumehood, and the user interface
2.3. F2 titration
The amount of carrier F2 used in the synthesis of [18F]F2 was determined by iodometric titration. The mixing chamber (Figure 3A) was filled with a known pressure of Ne/0.5% F2 gas and further filled with neon to a total pressure of 5 bar. The mixing chamber was opened to the illumination chamber, and the pressure was allowed to equilibrate for 1 minute. The gas mixture in the illumination chamber was bubbled through 1 mL of 1M KI solution, and the chamber was flushed 3 times with neon. The resulting solution was titrated with 0.01M Na2S2O (when the solution color turned very pale yellow, starch indicator, 0.5 mL, was added). The amount of carrier F2 gas was calculated from the total amount of Na2S2O used for titration.
2.4. Radionuclide production by cyclotron
[18F]F‐ aq was produced via the 18O(p,n)18F reaction. 18O‐enriched water (800 μL) was irradiated with a beam of 17 MeV, 10 μA protons using the MGC‐20 cyclotron for 5 minutes (Efremov Scientific Research Institute for Electrophysical Apparatuses [NIIEFA], Saint Petersburg, Russia). For the reactions with high activity, [18F]F‐ was produced using the TR‐19 cyclotron (Advanced Cyclotron Systems Inc Richmond, British Columbia, Canada) by irradiating 18O‐enriched water (3.6 mL) for 1 hour with a 19 MeV, 100 μA proton beam. An aliquot (1 mL) of the irradiated water was transferred to the synthesis apparatus for the reaction.
2.5. Production of [18F]CH3F
The irradiated water containing the [18F]F‐ aq was transferred to a reaction vessel containing K2CO3 (6‐8 mg), Kryptofix 222 (22‐28 mg), and 1 mL of MeCN. Azeotropic distillation was conducted at 100°C for 4 minutes. Following this, a further 1 mL of MeCN was added and the drying was continued for 4 minutes. CH3I (1.5 mmol) in 1 mL MeCN was added to the dry [18F]KF/K222 complex, and the reaction was conducted for 40 seconds at 100°C.
The resulting [18F]CH3F was transferred to a 60‐mL syringe and injected onto the gas chromatography column for purification. Neon was used as a carrier gas. The gas chromatography column was held at RT. A Geiger‐Muller radioactivity detector, placed on the outlet of the column, monitored the elution of [18F]CH3F. The purified product was collected in a stainless steel loop (od 1/16", id 0.5 mm) submerged in a liquid nitrogen trap. Upon collection, the stainless steel loop was allowed to warm to room temperature for 90 seconds. Subsequently, the Ne/F2 gas mixture, premixed to a total pressure of 5 bar as described earlier (see Section 2: F2 titration), was used to transfer the [18F]CH3F to the illumination chamber (Figure 3A). The final pressure of the gas mixture in the illumination chamber was 2.5 bar.
2.6. [18F]F2 production and [18F]NFSi labelling
The chamber, previously filled with [18F]CH3F/F2/Ne, was illuminated with the laser beam, and the resulting gas mixture was bubbled, at a flow of 20 to 25 mL/min, through the solution of the NFSi precursor in 0.9 mL of MeCN and 0.1 mL of H2O. The remaining volatile radioactive compounds were trapped in a waste bottle.
[18F]NFSi was not purified. The crude solution of [18F]NFSi was analyzed by analytical radioHPLC. The reported HPLC yield is an integrated yield based on the area of radioactive product peak compared to the total area of all radioactive peaks. The SA values of [18F]NFSi (SA[ 18 F]NFSi) were calculated from the analytical radioHPLC chromatograms as follows: The UV detector response was calibrated with known amounts of NFSi. The [18F]NFSi fraction was collected from the HPLC outlet, the radioactivity was measured, and the area of the UV peak corresponding to NFSi was determined. The areas of the NFSi peak in the calibration and area of that in the analytical chromatogram were compared, and the amount of NFSi was calculated based on the [18F]NFSi UV peak area.
During the initial screening reactions, 3 different illumination chambers were tested (Table 1). All of the chambers were coated with either an opaque layer of aluminum metal by vacuum evaporation or with TiO2 reflective paint. In each case, a small uncoated window was left as the laser beam inlet. On chamber A, only the terminal quartz glass window was coated with paint. The chambers were connected with stainless steel Swagelok ¼" fittings and teflon ferrules.
Table 1.
Properties of illumination chambers used for the experiments
| Chamber | Chamber material | Chamber shape and dimensions | Volume, cm3 | Chamber coating |
|---|---|---|---|---|
| A | Glass with quartz windows on ends |
|
10.3 | TiO2 |
| B C | Quartz |
|
9.8 | Al TiO2 |
| D | Quartz |
|
4.1 | Al |
[18F]CH3F was synthesized as described and transferred to the illumination chamber, and a known quantity of carrier F2 was added (Table 2). The mixture was illuminated with 30 000 laser pulses, and the produced gas was immediately used for the synthesis of [18F]NFSi. The chamber providing the highest SA[ 18 F]NFSi and HPLC yield was subsequently used to determine optimal number of laser pulses to promote the isotopic exchange reaction. Thus, the effect of varying the amounts of carrier F2 was investigated, keeping all other conditions unchanged.
Table 2.
Results of experiments conducted using different illumination chambers
| Chamber | nF2 (nmol) | A[ 18 F]F ‐ (GBq) | Acrude (MBq) | SA[ 18 F]NFSi (GBq/μmol) | [18F]NFSi HPLC Yield (%) |
|---|---|---|---|---|---|
| A | 1260 | 3.15 | 142 | 0.04 | 36 |
| A | 1260 | 3.15 | 360 | 0.15 | 34 |
| B | 1280 | 3.75 | 352 | 0.04 | 15 |
| B | 1280 | 2.76 | 608 | 0.12 | 15 |
| C | 1280 | 3.30 | 451 | 0.04 | 9 |
| C | 1280 | 2.88 | 618 | 0.10 | 5 |
| C | 1280 | 3.60 | 498 | 0.09 | 5 |
| D | 1090 | 3.06 | 393 | 0.05 | 13 |
| D | 1090 | 3.12 | 333 | 0.04 | 9 |
Abbreviation: [18F]NFSi, [18F]‐N‐fluorobenzenesulfonimide; HPLC, high‐performance liquid chromatography; SA[ 18 F]NFSi, SA values of [18F]NFSi.
The values are corrected to end of synthesis (EOS), except for the A[ 18 F]F ‐, which was measured at the start of synthesis. nF2 = amount of carrier F2.
The screening reactions were conducted with low starting activity (A [ 18 F]F ‐ = 3.25 ± 0.54 GBq). The conditions that resulted in the highest SA[ 18 F]NFSi were further used for reactions with high A [ 18 F]F ‐ (36 ± 2 GBq) to obtain high SA[ 18 F]NFSi.
2.7. Statistical methods
The results are reported as means ± SD of n = 3‐5. All statistical analyses were performed using Microsoft Excel 2010. Differences between the HPLC yields and SA[ 18 F]NFSi obtained using different conditions were tested using the unpaired t‐test. Differences were considered statistically significant if P < .05.
3. RESULTS
[18F]F2 was successfully produced and subsequently used to label [18F]NFSi, which was identified by analytical HPLC (Figure 2). Analysis of the crude reaction mixture showed some UV‐active impurities that separated well from the product peak. Two radioactive impurities with retention times of 1 and 8.5 minutes were also observed.
3.1. Chamber shapes and amount of laser pulses
The investigation of chamber shapes (Table 2) showed that use of the chamber A resulted in the highest HPLC yield of [18F]NFSi, and hence, this chamber was chosen for all further experiments. The comparison of different coating materials (chambers B and C) (Table 2) indicated that aluminum is the better reflective material; however, the aluminum layer was also easily destroyed during the laser illumination. A comparison of the amount of laser pulses used to promote the isotopic exchange demonstrated that 30 000 pulses gave a higher yield and SA[ 18 F]NFSi than 15 000 pulses. However, increasing the number of laser pulses to 60 000 did not give significantly different results for either SA[ 18 F]NFSi (P = .16) or HPLC yield (P = .051) of [18F]NFSi (Table 3). Hence, subsequent reactions were conducted with 30 000 laser pulses.
Table 3.
Results of the experiments conducted with different amounts of pulses
| Pulses | A[ 18 F]F ‐ (GBq) | Acrude (MBq) | SA[ 18 F]NFSi (GBq/μmol) | [18F]NFSi HPLC Yield (%) | N |
|---|---|---|---|---|---|
| 15 000 | 3.2 ± 0.5 | 420 ± 100 | 0.19 ± 0.12 | 10 ± 5 | 4 |
| 30 000 | 3.6 ± 0.5 | 640 ± 330 | 0.66 ± 0.41 | 23 ± 5 | 4 |
| 60 000 | 3.0 ± 0.2 | 260 ± 24 | 0.40 ± 0.08 | 17 ± 1 | 3 |
Abbreviation: [18F]NFSi, [18F]‐N‐fluorobenzenesulfonimide; HPLC, high‐performance liquid chromatography; SA[ 18 F]NFSi, SA values of [18F]NFSi.
All experiments were done with 380 nmol of carrier F2. The values presented are corrected to end of synthesis (EOS), except for the A[ 18 F]F ‐, which was measured at the start of synthesis.
3.2. Amount of carrier F2 gas
Decreasing the amount of carrier F2 led to an increase of SA[ 18 F]NFSi. In the experiments starting with low A[ 18 F]F ‐, the highest SA[ 18 F]NFSi (1.2 ± 0.6 GBq/μmol) was obtained with 190 nmol of carrier F2 (Table 4). Lowering the amount of carrier F2 to 95 nmol did not increase the SA[ 18 F]NFSi. The correlation between the total radioactivity of the the crude [18F]NFSi solution (Acrude) and the SA[ 18 F]NFSi is shown in Figure 4.
Table 4.
A comparison of the experiments performed with different amounts of carrier F2
| Entry | nF2 (nmol) | A[ 18 F]F ‐ (GBq) | Acrude (MBq) | [18F]NFSi HPLC Yield (%) | SA[ 18 F]NFSi (GBq/μmol) | N |
|---|---|---|---|---|---|---|
| 1 | 1720 | 3.0 ± 0.5 | 380 ± 160 | 29 ± 2 | 0.07 ± 0.05 | 5 |
| 2 | 1180 | 3.5 ± 0.6 | 570 ± 230 | 31 ± 3 | 0.16 ± 0.07 | 4 |
| 3 | 380 | 3.6 ± 0.5 | 640 ± 330 | 23 ± 5 | 0.66 ± 0.41 | 4 |
| 4 | 190 | 2.9 ± 0.4 | 500 ± 180 | 13 ± 6 | 0.93 ± 0.43 | 4 |
| 5 | 95 | 3.1 ± 0.5 | 430 ± 78 | 5 ± 2 | 0.57 ± 0.37 | 3 |
| 6 | 190 | 35.8 ± 1.9 | 4100 ± 2400 | 13 ± 3 | 10.3 ± 0.9 | 3 |
The values presented are corrected to end of synthesis (EOS), except for the A[ 18 F]F ‐, which was measured at the start of synthesis. Entries 1 to 5 were conducted with a constant amount of A[ 18 F]F ‐ and a varied amount of carrier F2. Entry 6 was conducted with 10 times higher A[ 18 F]F ‐ than the other entries.
Figure 4.

Correlations between the SA[ 18 F]NFSi and Acrude. The results for experiments with particular amounts of carrier F2 are plotted as separate series. Linear trendlines are plotted for each series. The markers in red represent the series corresponding to the lowest amount of carrier used, where the behavior deviates from that of the others. SA[ 18 F]NFSi, SA values of [18F]NFSi
No significant difference in the HPLC yield was observed when decreasing the amount of carrier F2 from 1720 to 1180 nmol (P = .096). As the quantity of carrier was decreased from 1180 to 95 nmol, a gradual decrease in HPLC yield was observed (Table 4).
The best trial conditions (chamber A, 30 000 laser pulses and 190 nmol of carrier F2) were used in experiments with high A[ 18 F]F ‐. These provided a SA[ 18 F]NFSi of 12.7 ± 1.2 GBq/μmol and a [18F]NFSi HPLC yield of 13 ± 3%.
4. DISCUSSION
A comparison of different illumination chambers showed that chamber A gave better results for the [18F]NFSi labelling than the chambers B, C, or D. This can be attributed to the long path length travelled by the laser beam in the reaction gas mixture before it is reflected. The cylindrical geometry of the chamber allows direct illumination of a larger proportion of the gas, while in the spherical chambers (chambers B, C, D), most of the gas is illuminated with the reflected photons. Although aluminum was the superior reflective material, the coating was easily destroyed by the laser beam and the illumination chamber had to be recoated with a new layer of aluminum every 3 to 4 syntheses and was hence not a practically useful coating material.
As expected, decreasing the amount of carrier F2 increased the SA[ 18 F]NFSi, with a maximum of 0.93 ± 0.43 GBq/μmol, which was obtained with 190 nmol of F2. The SA[ 18 F]NFSi obtained in the screening reactions and conducted with various amounts of carrier F2 were presented as a function of the Acrude (Figure 4). Since it is not practical to determine the radioactivity of the [18F]CH3F, we decided to use the Acrude as a measure of activity for the isotopic exchange reaction, as it accounts for the radioactivity that has been converted to either to [18F]F2 or [18F]HF. Hence, the gradient of the trendlines for each data set (Figure 4) can be used as a measure of the dependence of the SA on the radioactivity of [18F]CH3F used for the isotopic exchange reaction. At levels lower than 190 nmol of carrier F2, the SA[ 18 F]NFSi decreased (Table 4), suggesting that during the illumination, there is a degree of consumption of the highly reactive atomic fluorine by reaction with the chamber walls or by side reactions generating [18F]tetra‐fluoromethane and [18F]hydrogen fluoride (Figure 1). As a result, this data series no longer followed the trend displayed in Figure 5. While the loss of atomic fluorine was lower than that of the previously published discharge method,10 this finding suggests that there is a constant quantity of atomic fluorine that will be lost during the reaction independent of the amount of carrier F2 added. Because the amount of carrier is decreased to lower and lower amounts, this constantly consumed quantity represents an increasingly larger proportion of the carrier F2.
Figure 5.

Graph showing the linear correlation between the SA[ 18 F]NFSi and the theoretical maximum SA, which was calculated by dividing the A[ 18 F]F ‐ (decay corrected to EOS) by the amount of carrier F2 (nF2). The data series for the lowest amount of carrier used (red), where the behavior deviates from that of the others was excluded when determining the trendline. The insert in the figure is an enlargement demonstrating the excellent linear fit even at low values
Figure 5 shows the linear correlation between the SA[ 18 F]NFSi and the theoretical maximum SA, which was calculated by dividing the initial [18F]fluoride activity, decay corrected to end of synthesis (EOS), by the amount of unlabelled carrier F2 used in the reaction. Hence, the slope of the trendline presented on the graph (0.067, R2 = 0.9997) corresponds to the average radiochemical yield of 6.7% (decay corrected to EOS) of [18F]F2 from [18F]F‐ for all the data sets that fit the trendline. This yield corresponds to the overall yield for the entire synthesis of [18F]NFSi from [18F]fluoride and represents a combination of yields 1, 2, and 3, as shown in Figure 1. If all of these yields were 100%, the SA[ 18 F]NFSi would be the same as the activity of the [18F]fluoride (A[ 18 F]F ‐) introduced divided by the molar amount of carrier (nF2) added, ie, the units of the horizontal axis in Figure 5, and the slope of the trendline would be unity.
Since the scaling of the SA[ 18 F]NFSi from low to high radioactivity experiments, at a constant amount of carrier, mirrors that of the A[ 18 F]F ‐ (Table 4), it is confirmed that the total molar amount of CH3F is essentially the same in all of the experiments.13 Hence, using the presented conditions, the only variable that the SA[ 18 F]NFSi depends upon is the amount of A[ 18 F]F ‐.
5. CONCLUSION
Vacuum ultraviolet photons were successfully used for the production of [18F]F2. This proof‐of‐concept study resulted in the production of [18F]F2 with a highest SA of 10.3 ± 0.9 GBq/μmol (decay corrected to EOS), a value that would be sufficient for the production of tracers such as 6‐[18F]fluoro‐DOPA, [18F]CFT, or [18F]EF5. The use of a commercially available excimer laser and the simplicity of the process will facilitate the application of this method in different radiochemistry laboratories.
ACKNOWLEDGEMENTS
The authors are grateful to Prof Gouverneur and her research group (Chemistry Research Laboratory, University of Oxford) for providing the NFSi precursor. This study was funded by the European Community's Seventh Framework Programme: FP7‐PEOPLE‐2012‐ITN‐RADIOMI‐316882 and by a grant from the Academy of Finland (no. 266891).
CONFLICT Of INTEREST
The authors declare that they have no conflicts of interest.
Krzyczmonik A, Keller T, Kirjavainen AK, Forsback S, Solin O. Vacuum ultraviolet photon–mediated production of [18F]F2 . J Label Compd Radiopharm. 2017;60:186–193. https://doi.org/10.1002/jlcr.3489
Anna Krzyczmonik and Thomas Keller contributed equally to this study.
REFERENCES
- 1. Haaparanta M., Bergman J., Laakso A., Hietala J., Solin O., [18F]ß‐CFT ([18F]WIN35,428), a radioligand to study the dopamine transporter with PET: biodistribution in rats, Synapse 1996, 23, 321–327. [DOI] [PubMed] [Google Scholar]
- 2. Koch C. J., Evans S. M., Non‐invasive PET and SPECT imaging of tissue hypoxia using isotopically labeled 2‐nitroimidazoles, Adv. Exp. Med. Biol. 2003, 510, 285–292. [DOI] [PubMed] [Google Scholar]
- 3. Schrobilgen G., Firnau G., Chirakal R., Garnett E. S., Synthesis of [18F]XeF2, a novel agent for the preparation of 18F‐radiopharmaceuticals, J.C.S. Chem. Comm. 1981, 4, 198–199. [Google Scholar]
- 4. Jewett D. M., Potocki J. F., Ehrenkaufer R. E., A gas‐solid‐phase microchemical method for the synthesis of acetyl hypofluorite, J. Fluorine Chem. 1984, 24, 477–484. [Google Scholar]
- 5. Teare H., Robins E. G., Årstad E., Luthra S. K., Gouverneur V., Synthesis and reactivity of [18F]‐N‐fluorobenzenesulfonimide, Chem. Commun. 2007, 23, 2330–2332. [DOI] [PubMed] [Google Scholar]
- 6. Oberdorfer F., Hofmann E., Maier‐Borst W., Preparation of 18F‐labelled N‐fluoropyridinium triflate, J. Labelled Compd. Radiopharm. 1988, 25, 999–1005. [Google Scholar]
- 7. Teare H., Robins E. G., Kirjavainen A., Forsback S., Sandford G., Solin O., Luthra S. K., Gouverneur V., Radiosynthesis and Evaluation of [18F]Selectfluor bis(triflate), Angew. Chem. Int. Ed. 2010, 49, 6821–6824. [DOI] [PubMed] [Google Scholar]
- 8. Blessing G., Coenen H. H., Franken K., Qaim S. M., Production of [18F]F2, H18F and 18Faq − using the 20Ne(d, α)18F process, Appl. Radiat. Isot. 1986, 37, 1135–1139. [Google Scholar]
- 9. Hess E., Blessing G., Coenen H. H., Qaim S. M., Improved target system for production of high purity [18F]fluorine via the 18O(p,n)18F reaction, Appl. Radiat. Isot. 2000, 52, 1431–1440. [DOI] [PubMed] [Google Scholar]
- 10. Bergman J., Solin O., Fluorine‐18‐labeled fluorine gas for synthesis of tracer molecules, Nucl. Med. Biol. 1997, 24, 677–683. [DOI] [PubMed] [Google Scholar]
- 11. Forsback S., Solin O., Post-target produced [18F]F2 in the production of PET radiopharmaceuticals, Radiochem. Acta. 2015, 3, 219–226. [Google Scholar]
- 12. Smart B. E., In Molecular Structure and Energetic, (Eds. Smart J. F., Greenberg A.), Vol. 3, VCH Publishers, Deerfield Beach, FL, 1986, pp. 141. [Google Scholar]
- 13. Solin O., Bergman J., Haaparanta M., Reissell A. Production of 18F from Water Targets. Specific Radioactivity and Anionic Contaminants, Appl. Radiat. Isot. 1988, 10, 1065–1071. [Google Scholar]
