Abstract.
With the recent breakthrough in genetically expressed voltage indicators (GEVIs), there has been a tremendous demand to determine the capabilities of these sensors in vivo. Novel voltage sensitive fluorescent proteins allow for direct measurement of neuron membrane potential changes through changes in fluorescence. Here, we utilized ArcLight, a recently developed GEVI, and examined the functional characteristics in the widely used mouse somatosensory whisker pathway. We measured the resulting evoked fluorescence using a wide-field microscope and a CCD camera at 200 Hz, which enabled voltage recordings over the entire cortical region with high temporal resolution. We found that ArcLight produced a fluorescent response in the S1 barrel cortex during sensory stimulation at single whisker resolution. During wide-field cortical imaging, we encountered substantial hemodynamic noise that required additional post hoc processing through noise subtraction techniques. Over a period of 28 days, we found clear and consistent ArcLight fluorescence responses to a simple sensory input. Finally, we demonstrated the use of ArcLight to resolve cortical S1 sensory responses in the awake mouse. Taken together, our results demonstrate the feasibility of ArcLight as a measurement tool for mesoscopic, chronic imaging.
Keywords: voltage sensor, genetically expressed voltage indicator, cortex, in vivo, imaging, ArcLight
1. Introduction
With the recent breakthrough in genetically expressed voltage indicators (GEVIs),1 there has been a tremendous demand to quantify the capabilities of these sensors in vivo. Novel voltage sensitive fluorescent proteins allow for direct measurement of membrane potential changes through changes in fluorescence. These GEVIs, including ArcLight,2 VSFP 2.3,3 Butterfly 1.2,4 Quasar1,5 and mNeon-Ace,6 have shown incredible promise to record neural responses.7,8 However, these approaches have not yet been widely applied in scientific studies in the mammalian nervous system (for review Refs. 8 and 9). Although recent calcium probes have greatly increased the understanding of complex neural systems, they still offer only moderate temporal resolution (50 to 100 ms)10 and report only on byproducts of suprathreshold neural spiking activity through calcium responses. Additionally, many studies try to deconvolve the calcium signal to glean information about ongoing membrane potential with mixed success (for review Ref. 11). In contrast, voltage sensors allow for fast temporal information (i.e., milliseconds) and have the potential to report even subthreshold information.
We present an investigation into the functional capabilities of ArcLight, one of the sensors available as an in vivo probe of wide-field cortical signals. ArcLight,1 a modified GFP protein, has fast temporal resolution () with relatively large changes in fluorescence in response to membrane fluctuations. Although several investigators have demonstrated the capabilities of ArcLight, most of these studies have reported responses through in vitro models,12,13 Drosophila,2,14–17 or in the mouse olfactory system.2,18 Other sensors, including VSFP 2.3 (Ref. 3) and Butterfly 1.2,19 have been previously shown to be successful for in vivo cortical sensory recordings (for review Ref. 8). In this work, however, we are the first, to our knowledge, to demonstrate the use of ArcLight in cortical structures in the awake and anesthetized mammalian brain.
Here, we demonstrate that ArcLight produces a robust and reliable sensory evoked fluorescent response in the S1 barrel cortex to sensory stimulation. We found that in the S1 barrel cortex the spectral overlap with the hemodynamic activity was substantial in its raw form and required long imaging experiments and trial averaging to reduce noise. In order to address this large hemodynamic signal, we subtracted a scaled Off-ROI signal to remove ongoing noise. Although this method dramatically removes the hemodynamic response, there are several assumptions and concerns that limit the widespread use of this technique. Using this post hoc subtraction method, we found that the evoked response matched the fast temporal dynamics of other voltage indicators including voltage sensitive dye (VSD) RH1691,20–23 VSFP 2.3,23 and Butterfly 1.2.4 ArcLight showed clear stimulus-evoked fluorescence for stimuli with frequency content up to 20 Hz with high fidelity. Using paired local field potential (LFP) recordings, we determined a high correlation between the average LFP and ArcLight signals in response to sensory stimuli; however, on a single trial the two signals showed weak correlation. Finally, we were able to resolve sensory evoked fluorescence in awake mice. Based on these results, we conclude that ArcLight has a capacity to measure chronic in vivo cortical responses. ArcLight would be suited for in vivo experiments where a single fluorophore sensor is desired, in particular experiments that require long bouts of continuous imaging.
2. Methods
All procedures were approved by the Georgia Institute of Technology Institutional Animal Care and Use Committee and followed guidelines established by the National Institutes of Health.
2.1. Virus Delivery
At least four weeks prior to experimentation, six-week-old female mice (C57BL/6, Jackson Laboratories) were anesthetized using isoflurane, 3% to 5% in a small induction chamber, and maintained at 1% to 3% isoflurane. Following anesthetization, 1 to 2 small craniotomies were created over the barrel field of the primary somatosensory cortex (S1) according to stereotaxic measurements taken from the bregma (, and ). The virus was loaded into a Hamilton syringe (701-N). A custom pulled borosilicate glass pipette was filled with a silicone gel and secured onto the tip of the Hamilton syringe to increase taper and to reduce damage to the cortex caused during the injection. The injection pipette was initially lowered to the target depth below the pia surface () using a resolution stereotaxic arm (Kopf, Ltd.). Following a 1-min delay to allow for tissue relaxation, each animal was injected with of adeno-associated virus (AAV)1-hsyn1-ArcLight-D-WPRE-SV40 (UPenn Viral Vector Core, AV-1-36857P) at a flow rate of ( each for two injections). After injection, the pipette remained in place for an additional 5 min before slowly being removed from the brain. The craniotomies were then filled with bone wax or left to close naturally. In all cases, the skull was sealed by clamping the skin using wound clips. During the injection, mice were kept warm using a water heating system to maintain body temperature. Throughout the experiment, sterile techniques were used to keep the injection area clean and free from infection. Additionally, no antibiotics were given to prevent infection. All mice survived this minor procedure.
2.2. Headplate and Surgical Preparation
After at least four weeks postinjection, we secured a metal headplate to the skull for fixation in order to reduce vibration and allow head fixation during imaging experiments. The custom metal headplate (titanium) formed a ring (inner radius 5 mm) around the entire cortex and contained flared v-shape projections () for attachment to a custom vice to reduce vibration. Mice were initially anesthetized using isoflurane (3% to 5%) and then placed on a heated platform (FHC, Inc.) with a stereotaxic nose cone to maintain anesthesia. A large incision was made over the skull. The connective tissue and muscles surrounding the skull were removed using a fine scalpel blade (Henry Schein #10). A headplate was attached using a three stage dental acrylic, Metabond (Parkell, Inc.). The Metabond was chilled using ice, slowly applied to the surface of the skull, and allowed to cure for 5 to 10 min. After securing the headplate, the skull was left either exposed or was lightly thinned using a dental drill and covered with a thin layer of clear adhesive (LockTight 401, ULine, Inc.). We found that the Metabond dental acrylic alone was able to firmly adhere to the animal’s skull and could not be removed without destroying the adhered bone. During preparation for histological validation, the headplate could not be separated from the attached skull and the brain was extracted by removing the lower jaw. The final headplate and dental acrylic structure additionally created a well for saline that helped maintain skull transparency for imaging during the intact skull preparation. The headplate was then transferred to a flexible arm to align the camera for imaging of the cortex. The nose cone was realigned to allow for continuous delivery of isoflurane while having access to the whiskers. After surgery, the isoflurane levels were dropped to for all imaging and electrophysiological experiments. The animal’s heart rate, respiratory rate, blood oxygenation, and toe-pinch responses were constantly measured for anesthesia depth. Isoflurane levels were adjusted to maintain a constant level of light anesthetization, monitored by heart rate, respiration rate, and functional cortical response.
2.3. Whisker Stimulator
All single whiskers were stimulated by a galvanometer system (Cambridge Technologies) to yield high-fidelity sensory stimuli. The galvanometer stimulator has a 15-mm extension to target single whiskers. The galvanometer system was controlled using a custom developed hardware/software system (MATLAB Realtime Simulink, Mathworks). The real-time system controls the stimulus using two computers, a target and a host. The target computer ran a proprietary Linux kernel that was controlled by the host computer. The entire system was updated at a 1-kHz sampling rate, with a custom developed algorithm to output voltage commands using an analog output card (National Instruments). The galvanometer system was positioned from the mouse whisker pad and delivered deflections on the single whisker in the rostral–caudal plane. Unless otherwise noted, we used a simple exponential sawtooth (rise and ) for punctate whisker deflections.24 The reported waveform stimulus velocity was determined as the average velocity during the waveform (). All stimulus waveforms were delivered in a pseudorandom order with at least 4 s between trials to reduce potential confounds. Due to the fast rising edge of the sawtooth, all latencies were defined relative to stimulus onset.
2.4. Cortical ArcLight and Intrinsic Imaging
ArcLight transfected mice were imaged through either intact or thinned skull using a wide-field fluorescence imaging system to measure cortical spatial activity (MiCam02HR Scimedia, Ltd.). During all imaging experiments, isoflurane anesthesia levels were lowered to . The headplate was used as a saline well to keep the bone surface wet during imaging, which dramatically increases transparency of the mouse’s skull. Some animals were chronically imaged through either intact or thinned skull covered with a glass coverslip and/or cyanoacrylate glue. The cortex was imaged using a CCD camera (Scimedia MiCam2 HR Camera) at 200 Hz. In all experiments, we had a field of view of with a total of a 1.6 magnification (). The particular optical system used in this work has an optical resolution of (, optical ). The camera in combination with the optics had a spatial resolution of per pixel; however, this resolution does not consider the scattering of the light in the tissue. During experimental imaging, the illumination excitation light was left continuously on. The entire cortical area was illuminated at 465 nm with a LED system (Scimedia, Ltd.) to excite the ArcLight fluorophore. The excitation light was further filtered (cutoff: bandpass filter, Semrock, Inc.) and projected onto the cortical surface using a dichroic mirror (cutoff: 495 nm, Semrock, Inc.). Collected light was filtered with a bandpass emission filter between wavelengths of (Semrock, Inc.). The imaging system was focused at below the cortical surface to target cortical layer . The procedures for mapping and recording sensory responses in the barrel cortex with the ArcLight voltage sensor are outlined below. For intrinsic imaging of the hemodynamic response, the cortical surface was illuminated by a 625-nm red LED (ThorLabs) and imaged with the same camera system as above, at a temporal resolution of 10 Hz. During intrinsic imaging, no emission filters were used. In order to evoke a cortical intrinsic response, the whisker was repetitively stimulated at 10 Hz for 6 s.
2.5. Recording ArcLight Fluorescent Sensory Responses in the S1 Barrel Cortex
The mouse’s whisker system was first mapped by imaging the rapid response to a high-velocity () sensory stimulus to at least three whiskers. We used three criteria to localize and isolate the barrel cortex: stereotaxic localization, relative evoked temporal response, and topographic mapping of cortical activation. All imaging experiments were centered on standard stereotaxic location of S1 ( lateral, 0.5 to 1.5 mm caudal from bregma). The resulting whisker responses were averaged over 20 trials. The response was determined to likely be from the barrel cortex if the average evoked fluorescence at the onset of the evoked response (20 to 25 ms after stimulation) was spatially limited to ∼ a area. Additionally, another criterion for functionally identifying S1 barrel cortex was through topographic mapping—if the center of mass of activation across whiskers moved consistently with the post hoc histologically identified barrels, activity was attributed to the barrel cortex. In some cases, S2 activation was detected in response to whisker deflection and was rejected based on an extreme lateral response ( to 4 mm from midline) and lack of a clear topographic representation of the whisker barrels. Once the barrel field was appropriately mapped, we selected a single whisker to be deflected for the entire experiment.
2.6. Simultaneous Blood Oxygenation Measurements
During experiments where the combination of blood oxygenation and blood flow was simultaneously captured, a small LED sensor was attached to the rodent’s hindpaw. The specific sensor (Easy Pulse sensor v1.1, Embedded Lab) was modified to have frequency filtering within the typical rodent heart rate (analog low-pass filter cutoff: 15 Hz). The recorded value measures the changes in the absorption of infrared light () to measure changes in blood oxygenation (and blood flow) over time. The reported values of the heart rate generated from the custom oxygenation sensor were cross validated with blood flow recordings of the commercially available physiological suite (Kent Scientific). Paired blood flow recordings and imaging was achieved using the simultaneous analog inputs in to the camera system at 4 kHz (MiCam02HR, Scimedia, Ltd.).
2.7. Simultaneous Local Field Potential Recordings and Analysis
In a subset of experiments, we simultaneously recorded the LFP along with the ArcLight imaging, using a similar prep as described above (see Sec. 2.4). After mapping the mouse cortical barrels, we removed a small portion of the bone over the selected barrel ( area) to have access to the underlying cortical surface. We lowered a low impedance tungsten electrode (, FHC Inc.) using a micromanipulator (Luigs & Neumann) to below the cortical surface to approximately layer . We identified the principle whisker through repetitive manual stimulation of different single whiskers. Once we localized the principle whisker, we attached the whisker stimulator and applied the sensory stimulus (above). We recorded electrophysiological data using a 128-channel cerebus system (Blackrock Microsystem LLC.) continuously sampled at 2 kHz. All LFP signals were notch filtered at 60 Hz to remove any electrical noise. Furthermore, we normalized LFP signals on a trial-by-trial basis by subtracting the average 200 ms prestimulus activity. In all cases, a zero-phase filter approach was utilized using custom MATLAB (Mathworks) scripts.
2.8. Chronic Multiday Imaging under Anesthesia
Three mice were first injected with the AAV construct and were outfitted with a custom developed headplate device to maintain stable recordings (see above). In order to increase the fluorescence recorded, the mouse’s skull was thinned to of the original thickness (or until transparent) using a surgical drill over the injected region (roughly ). After thinning, the mouse’s skull was sealed using clear adhesive (Loctite 401 Adhesive, Uline). During skull thinning, the ArcLight fluorescent responses were briefly mapped to identify and localize the barrel cortex. After implantation, mice were left to recover for at least 1 week before imaging again. Day 1 corresponds to the first imaging experiment after 1 week of recovery post headplate implantation. The same mouse whisker (A1) was imaged over the course of 28 days, specifically on days 1, 3, 5, 7, 14, 21, 28. Isoflurane anesthesia was held to similar levels across imaging experiments by maintaining heart rate between 500 and 600 bpm, monitored from the animal’s paw (Kent Scientific, isoflurane). During imaging the mouse cortical responses were mapped with at least two whiskers to identify the correct region and presented with a velocity stimulus (described above). The entire imaging experiment lasted to 2 h each day. After imaging, the cortical surface was covered with a silicone plug (Kwik—Cast, World Precision Instruments LLC) to prevent photobleaching of the fluorophore between experiments. Mice were imaged only during the specific time points listed above.
2.9. Awake Imaging
At least four weeks after ArcLight viral injection, mice were anesthetized under isoflurane and were headplated using the above stated protocol. Over the course of 3 days preceding the first imaging experiment, mice were routinely handled to gain familiarity with the imaging system and immobilization device. During this acclimatization period, mice were increasingly head fixed for longer periods of time, for 15, 30, and 45 min, respectively. During stimulation of the whisker, mice were prevented from interacting with the whisker stimulator by obstructing the path from the paws to the whisker. Mice were rewarded with sweetened milk (Nestle, Ltd.) throughout imaging, which greatly helped to reduce animal frustration. After 3 days of handling and acclimating, mice appeared to be calm while the head was immobilized in the headplate restraint system. During passive stimulation of the whiskers, the mice often actively moved their whiskers. Therefore, the galvanometer was placed 5 mm from the face to prevent the whisker from slipping out of the manipulator; however, the amplitude of the deflection was adjusted to maintain a consistent velocity stimulation () as presented in the anesthetized case (see above).
2.10. Histology
Histological samples were prepared by perfusing the animal transcardially with phosphate buffered saline (PBS) followed by 4% paraformaldehyde. Brains were postfixed overnight in 4% paraformaldehyde then transferred to PBS before sectioning. Thick sections were cut using a vibratome (, Leica) and either directly mounted or saved for staining. In some cases, we cryosectioned the postfixated brains to achieve thinner sections () for better imaging. Before sectioning, samples were submerged in 30% sucrose in PBS post fixation until saturated with sucrose (causing the tissue to sink). The tissue was then snap frozen and embedded in optimal cutting temperature compound (Tedpella, Inc.). Thin sections were cut on a cryotome (). ArcLight was stained against using a Rabbit anti-GFP polyclonal antibody (Abcam) and Alexa 488 secondary (Life Technologies, Inc.). After staining, the sections were then counterstained with Nissl (Neurotrace 640 Life Technologies, Inc.) to isolate neurons. ArcLight was imaged using the 405-nm laser on an NLO 710 confocal microscope (Zeiss) and processed using Zen software (Zeiss).
2.11. Voltage Imaging Data Analysis
In this section, we have limited our description of the analytical methods used to the processing of the raw fluorescence signal. For specific description of the methods for each figure shown, see the corresponding results Secs. 3.2 and 3.3. All data analyses for ArcLight imaging were accomplished using custom written image-analysis software (MATLAB 2015a, Mathworks, Inc.). A general outline of the image analysis is shown in Fig. 3.
Raw images were loaded and converted from the proprietary file format of the imaging system using custom scripts. Due to the natural decay of the fluorescent signal caused by photobleaching, each trial was first normalized to a baseline and reported as a percent change in fluorescent activity (). The measurement was calculated by subtracting and dividing each trial’s fluorescence by the frame preceding the stimulus delivery
where is the frame of stimulus delivery ( at ). A single region of interest (ROI) was identified using the largest () area response at 25 ms post stimulus onset.
After normalization to a measurement, the signal still contained a large component of hemodynamic noise [see Fig. 3(b)]. The observed noise was determined to be centered around 7 to 10 Hz, which corresponded with the animals’ ongoing heartbeat [see Fig. 3(b), Appendix A1]. This hemodynamic noise was removed using a highly correlated ROI (Off-ROI). This Off-ROI was defined as the average pixel region ( area) at least 48 pixels () away from the ROI with the highest average correlation of fluorescence during the first nonstimulus trial (see Appendix A2). The Off-ROI region was fixed during all subsequent trials. The separation of 1 mm typically results in a background measurement that is highly correlated with the ROI while avoiding the evoked response. We found that this distance did not cause changes in the evoked mean response [see Fig. 3(f) and corresponding results Sec. 3.2 and Appendix A3], while allowing for subtraction of ongoing hemodynamic fluctuations.
In each trial, the activity in the Off-ROI 200 ms preceding stimulus delivery was projected onto the ROI using a linear regression model [Fig. 3(c)], which was then removed from the activity within the ROI to produce the final time series data that were used for all calculations (see Fig. 3 for more details). Due to the fluorophore,1 positive changes in membrane potential correspond to a decrease in ArcLight fluorescent activity. Therefore, all traces here have been inverted to show a decrease in fluorescence as an increase in magnitude for aesthetic purposes.
2.12. Statistics
In all cases, we first determined if the specific data sets were normally distributed using the Lilliefors test for normality.25 If the data were normal, we used the appropriate (paired or unpaired) -test for statistical difference. If the population was determined to have nonnormal distributions, we conducted nonparametric Wilcoxon signed-rank tests to determine statistical significance. All tests were conducted using the MATLAB Statistics Toolbox (Mathworks, Inc.).
3. Results
3.1. Experimental Setup and Histological Validation of Genetic Expression in Barrel Cortex
We validated the location of expression of the ArcLight injections in the S1 barrel cortex through postexperiment fixation and histological analysis of transfected animals. We localized the GEVI ArcLight in the mouse barrel cortex by injecting of AAV1-hsyn1-ArcLight-D-WPRE-SV40 (UPenn Viral Vector Core, AV-1-36857P) using stereotaxic coordinates and a microinjector system (see Sec. 2.3). Similar to other published work, we found that under the human synapsin promotor (hsyn1), ArcLight expressed predominantly in layers and 5 of the mouse cortex26 [Figs. 1(b)–1(c)]. Based on the limitations of blue light penetration to the superficial cortical layers, our recorded fluorescence signals are a combination of layer somatic, axonal, and dendritic information along with layer 5 apical dendrites. Under further magnification, ArcLight appeared to express across the cellular membrane [Fig. 1(d)], suggesting that the wide-field response is a combination of all membrane related neural responses from the expressed areas (i.e., soma, dendrite, axon). ArcLight has been shown in previous work to highly express in the cellular membrane.1,27 We confirmed the expression of ArcLight to the neural membrane, through anti-GFP [Fig. 1(d)] and Nissl [Fig. 1(e)] staining, the combination of which is shown in Fig. 1(f). ArcLight is derived from the GFP molecule,2 and therefore, was counterstained with polyclonal anti-GFP molecules to improve signal to noise over background fluorescence. These observations of ArcLight neuronal membrane expression are highly consistent with recent work in the olfactory bulb under similar conditions with the hsyn1 promoter.18 The histology highlights the ability of ArcLight, under hsyn1 promoter, to genetically target all neural membranes, which offers higher selectivity than traditional VSDs that bind to all cellular membranes (neuronal and glial).
3.2. ArcLight Response to Single Whisker Deflections
We measured the spatio-temporal ArcLight fluorescence in the cortex using a fluorescence microscope and a CCD camera system [imaged at 200 Hz, for setup see Fig. 1(a)]. We first applied our sensory stimuli to a single mouse whisker using a customized actuator (see Sec. 2) and recorded the evoked fluorescence response in the primary somatosensory cortex (S1) (Fig. 2). Specifically, we presented a strong () stimulus to a single whisker and recorded the evoked fluorescent cortical response [Fig. 2(a)]. Stimulus features such as these have been widely used across a range of laboratories including our own24,28 inspired by high-velocity transients of whisker motion observed in active sensing.29–31
In response to these single whisker pulsatile deflections, we observed a change in cortical fluorescence consistent with the reported topography of S1 barrel cortex. Each imaging experiment consisted of 50 to 100 trials, which were subsequently averaged, and postprocessed using the stated methods (Sec. 2.11). Unless otherwise noted, we utilized an Off-ROI subtraction method to remove the hemodynamic signal on a pixel by pixel basis across the entire image. For every experiment, an Off-ROI was selected, scaled, and subtracted from the ROI to reduce ongoing hemodynamic noise (see Sec. 2.11 and Fig. 3 for more details of this procedure). Note that the Off-ROI subtraction method produced similar results to the raw averaged signal (data not shown). Similar to published wide-field VSD imaging,28,32–35 the recorded voltage response initially started in a small region approximately the size of a single mouse barrel and rapidly increased to a much larger area encompassing much of the barrel cortex [Fig. 2(a), at poststimulus]. The fluorescence then decayed over the course of , until returning to baseline activity. We calculated the total area of activation by normalizing each dataset as a percent change over each trial’s baseline activity (, see Sec. 2.11), and spatially smoothing the images with a small Gaussian filter (similar to Ref. 28). The total area of activation was calculated as the cortical area corresponding to the 50% contour of the mean peak response between 25 and 35 ms poststimulus (see Sec. 2.11). We measured the initial spatial response to be on average [standard deviation (SD)] ( experiments, 7 animals). This initial activation corresponds to a region of , or 1 to 2 cortical barrels.36,37 These results correlate well with intracellular recordings from layer cortical neurons that show that surrounding barrels receive subthreshold sensory input from a single whisker.38
In order to determine if the area of expression caused by the viral injection changed the observed evoked spatial response, we compared the evoked spatial response across different mice with different patterns of ArcLight expression. Using a noninjected mouse, we determined the overall level of baseline autofluorescence with our imaging system. We developed a threshold (two times the baseline average autofluorescence from the noninjected mouse) to approximate the area expressing the ArcLight protein. We found that our cortical injections produced expression across ( SD) of the recorded field of view. We found no correlation between the expressed area and the evoked spatial response ().
To characterize the temporal dynamics of the evoked signal, we reduced the spatial information down to a single ROI corresponding to a mouse cortical barrel. A single ROI square was selected as the area of maximal response to the whisker deflection [see box outlined at 35 ms, Fig. 2(a)]. The following analysis was conducted on the average response in each experiment (containing 50 to 100 trials). For every experiment, an Off-ROI was selected, scaled, and subtracted from the ROI to reduce ongoing hemodynamic noise (see Sec. 2.11 and Fig. 3 for more details of this procedure). A representative temporal response from the ROI during a single imaging experiment is shown in Fig. 2(b) [grand average Fig. 2(c)]. In order to provide the best estimate of the temporal parameters based on our sampling frequency (200 Hz), we approximated the measurements using linear interpolation and approximated the signal corresponding to the observed frame. The average signal onset, defined as the poststimulus time corresponding to the first frame reaching 10% of the maximal value, was determined to be (SD). We calculated the average time from stimulus presentations to 50% and 90% of the peak response as and (SD), respectively (across experiments, , 7 animals). The mean ArcLight cortical response signal reached peak intensity at (SD) poststimulus with a mean peak response of (SD) . Given the intrinsic ArcLight fluorophore reported rise-time, time between onset and peak, of 10 to 20 ms,1,2,18 our observations here correspond well with published in vivo anesthetized cortical extracellular single unit activity in layer (Ref. 39) and simultaneously recorded LFP signals (see Fig. 4). Upon reaching peak, the signal decayed back to baseline over a highly variable range from 5 to 300 ms. Across all animals [Fig. 2(c), experiments, 7 animals], the mean decay rate to 50% and 25% of maximal response was and (SD) [median: 50 and 155 ms], respectively. A smaller secondary activation typically occurred to 200 ms poststimulus [Figs. 2(b) and 2(c)]. A large secondary onset was found only in of experiments, and was defined as a period of rising activity for a duration of poststimulus, and has been shown in widefield recording using VSDs.40
The determined amplitude of the average evoked ArcLight response is similar to other reported voltage sensors’ average peak responses in the S1 barrel cortex [mean evoked amplitudes, VSFP 2.3: ,23 RH1691: ,23 and RH1691: 21] regardless of imaging setup, sampling rates, and anesthesia. Note even the same sensor (e.g., RH1691)20,21 has produced a wide range of reported amplitudes and varies heavily on experimental preparations. The average peak amplitude of the evoked response is similar, but reduced compared to in vivo ArcLight responses from the olfactory bulb (reported ,18 sampled at 125 Hz). The spatial and temporal results are also similar to published wide-field imaging responses using organic VSDs [RH 1691,20,21,32 and RH 795 (Ref. 40)] as well as other GEVIs [VSFP 2.3 (Ref. 23)]. Taken together, this evidence demonstrates that on average ArcLight is able to resolve sensory evoked cortical responses that are comparable to other voltage sensors.
One key benefit of wide-field imaging using voltage sensors is the ability to resolve functionally relevant cortical structures. As an initial validation, in one experiment, we compared the spatial component of the ArcLight activation to that obtained through conventional intrinsic imaging [see Sec. 2.11, Fig. 2(d), left panel ArcLight, right panel intrinsic imaging]. This resulted in good topographical correspondence between the two approaches. We further recorded spatial activity using ArcLight when stimulating multiple individual whiskers to generate an activity map of the barrel cortex. We stimulated surrounding whiskers one-by-one using the precise galvanometer while recording the evoked sensory response using ArcLight. We found that multiple whisker representations could be isolated across the barrel cortex [Fig. 2(e)]. When we superimposed these cortical activation regions, the resulting ArcLight responses correlated well with the stereotaxic alignment of a typical histological barrel map (data not shown).
3.3. ArcLight Shows Slow Rate of Photobleaching In Vivo
To achieve the fidelity of imaging presented in Fig. 2, we developed several analytical tools that are described in-depth here. ArcLight has been shown to be very photostable over long periods of excitation in vitro12,13,18 and therefore is ideal for long imaging experiments. We also found this to be the case here, where ArcLight showed only a small, slow linear decay of fluorescence over time. We determined this by continuously exposing the cortical surface to constant blue (465 nm) excitation during each imaging experiment () and applied either a whisker stimulus or no stimulus. During the no-stimulus portion, we calculated the mean fluorescence in the selected ROI and fit a linear model to predict the decay over time. The average slope of the linear decay of the ArcLight was found to be a standard error of the mean (SEM) change in fluorescence per minute [ experiments across 7 mice; mean , Fig. 3(a)], with LED system, Sec. 2.4]. Based on our optics, this LED excitation corresponds to an approximate (or 0.4 mW/mm2)overall intensity. The overall result of the slow rate of photobleaching appears to be consistent with in vitro findings.2 We subsequently accounted for the ArcLight photobleaching decay, as well as differing amounts of overall baseline fluorescence, by normalizing each frame as a percent over the baseline response . This approach has been widely used in fluorescence imaging as a method to normalize and compare across animals.41 In this work, we define our baseline fluorescence () as the single frame when the stimulus was delivered.
3.4. Reducing Hemodynamic Signal with Post Hoc Off-ROI Subtraction Analysis
In addition to the decay caused by the photobleaching, we observed large fluctuations in the fluorescence signal at frequencies consistent with hemodynamics [Fig. 3(b), 7 to 10 Hz]. Hemodynamic signal is a common feature of blue-green light excitation fluorophores due to the overlapping absorption spectra of hemoglobin.19,42 We directly measured the hemodynamic signal in the fluorescence imaging using simultaneous recording of the blood oxygenation with a custom developed blood oxygenation sensor on the mouse’s hindpaw (see Sec. 2.6). We determined that the hemodynamic signal was moderately correlated at fixed 30 ms delay (mean Pearson correlation: 0.54 (), across 102 trials) with changes in blood flow and oxygenation in the hind-paw. The general single-trial pattern of activity between the two signals showed good correspondence [Fig. 3(b)], suggesting that the observed oscillatory signal was likely due to the overlapped excitation frequency (465 nm) between the ArcLight fluorophore and hemoglobin (see Appendix A3). Although the blood oxygenation signal is similar to the hemodynamic signal in the voltage fluorescence imaging, we observed differences in the two signals, specifically in the introduction of larger artifacts likely due to respiration [Fig. 3(b), black asterisks (*)] that were absent in the fluorescence response. Therefore, we sought additional methods as a model to remove the ongoing hemodynamic response in the fluorescent signal. A simple notch filtering at the heartbeat frequency (7 to 10 Hz) dramatically distorted and reduced the evoked ArcLight response and was thus not a viable approach (see Appendix A1).
To counter the hemodynamic interference, we instead developed a simple post hoc linear model to take advantage of the highly correlated nature of the hemodynamic signal in the fluorescence signal across pixels. Using this method, we extracted single-trial information by subtracting a linear projection of an Off-ROI signal from the ROI time series. The Off-ROI was selected as a highly correlated region at least 1 mm away from the ROI, as defined from the evoked response [Figs. 3(b) and 3(c), Sec. 2.11, mean distance between ROI and Off-ROI: 1.35 mm, range of distance: 1.15 to 1.85 mm]. The Off-ROI region was always placed further than the 50% contour of the maximal sensory evoked response (mean max evoked radius: ). To avoid subtracting stimulus information, we used only 200 ms of prestimulus activity to determine the corresponding coefficients of the projection. Similar to other widely used subtraction methods,43 there is a potential of the introduction of neural responses and the negation of common brain states. Despite these limitations, we found this Off-ROI subtraction technique was suitable for our purposes of measuring the relative evoked activity caused by the sensory stimulus.
Using both fluorescence normalization and Off-ROI subtraction, we dramatically reduced the ongoing noise and improved the single-trial signal-to-noise ratios (SNRs) [Fig. 3(d), single-trial example; Fig. 3(f), trial averaged]. Qualitatively, we observed that the Off-ROI subtraction significantly reduced the hemodynamic component of the ArcLight signal, without compromising the evoked response, seen in both time series and spatial representations [Figs. 3(d), 3(e), for details see Appendix A2, Figs. 9 and 10]. To better quantify the reduction in noise, we assessed the ability to detect evoked responses from the ArcLight signal with and without Off-ROI subtraction. Here, we measured single-trial SNR by comparing the mean evoked response between 25 and 30 ms poststimulus to the variability of ongoing noise, across all sessions ( experiments, 3008 single trials). The noise (N) was defined as the mean standard deviation of the ArcLight signal over the 200-ms window before stimulus onset. We found that with trial averaging the ArcLight response could be detected [mean response SNR: 11.63 (±9.5 SD); however, single trials were too embedded in the noise to be clearly separated [single-trial SNR: 0.99 ()]. In contrast, the Off-ROI subtraction method dramatically increased both mean [30.0 ()] and single trial [4.02 ()] SNRs [Figs. 3(d), 3(f)]. The ArcLight SNR of the average response (with and without Off-ROI subtraction) is comparable to other voltage indicators, (VSFP Butterfly 1.2).19 However, without Off-ROI subtraction, the raw single-trial SNR is noticeably worse than the reported single-trial SNR values in other GEVIs [VSFP Butterfly 1.2,19 and VSFP 2.3 (Ref. 3)]. However, it is important to note that these fluorescence resonance energy transfer (FRET)-based GEVIs utilize post hoc ratiometric subtraction methods to improve SNR. By gaining access to single-trial information with Off-ROI subtraction, we dramatically increase the usability for wide-field imaging of ArcLight in behaviorally relevant contexts.
3.5. Comparison of ArcLight Response to Simultaneously Recorded Local Field Potential
In order to validate ArcLight as a correlate of neural activity, we simultaneously measured the LFP while imaging the cortical response to punctate whisker deflections (Fig. 4). Based on the histological analysis and the limitations of blue light excitation,44 we expect that the ArcLight response is predominantly from layer neurons (Fig. 1). Thus, we inserted a low impedance electrode to below the cortical surface near the centroid of the evoked response and simultaneously recorded the corresponding LFP during an anesthetized imaging experiment (see Sec. 2.7). The following data represent comparisons between the simultaneously recorded ArcLight and LFP responses (for details see Sec. 2.7). The LFP signal has been notched filtered at 60 Hz.
We compared the resulting stimulus evoked responses in the LFP and the evoked fluorescence and found similar characteristics between the two signals, shown in Fig. 4(b). Specifically, we found that the average LFP and ArcLight responses during whisker stimulation were correlated [mean peak Pearson correlation: 0.65 ()] ( experiments, across 2 mice). Furthermore, we determined the peak correlation between the LFP, and the ArcLight response was 35 ms ( SD, median: 25 ms), delayed relative to the LFP signal [Fig. 4(b)]. Note that the determined ArcLight peak response was highly variable (range 25 to 100 ms). During the simultaneous ArcLight-LFP experiments, the average peak response was (SD) milliseconds poststimulus (median: 60 ms, paired recordings, across 2 mice).
We directly compared the difference in temporal dynamics between the evoked LFP and the cortical ArcLight responses [Fig. 4(c)] by measuring the onset, 10% to 90% rise time, and the 50% decay time for the simultaneously collected LFP and ArcLight signals. Note that the relationship between the LFP and the membrane potential is quite complex (for review see Ref. 45), where the exact coupling between the LFP and the membrane potential is still being discovered.46 Other work has suggested that the LFP is an approximation of the temporal derivative of the membrane potential.47 However, more recent works have noted the potential influence of filtering properties on relating the LFP to the membrane potential, and thus caution needs to be used in interpreting this relationship.48 Our comparison between the temporal dynamics of the LFP and the ArcLight response may not account for this complex relationship between the LFP and the membrane potential.
We found that in general, the response onset [mean onset () LFP: 8.6 (0.75) ms, ArcLight: 20 (5) ms] and rise time [mean rise time () LFP: 4.7 (1.7) ms, ArcLight: 30 (15) ms] of the evoked cortical ArcLight signal were 10 to 25 ms later than the LFP response [Fig. 4(c)]. However, the mean ArcLight signal decay time was prolonged relative to the LFP decay time [mean decay () LFP: 35.5 (18.5) ms, ArcLight: 170 (108) ms]. This long excitatory tail has been a characteristic of other voltage sensitive imaging techniques, including VSDs,40 which have substantially faster temporal dynamics, as well as other GEVIs including VSFP 2.3.23 Therefore, this slow decay from the initial response may not entirely represent limitations of the molecule, but potentially additional physiologically relevant information. An alternative possibility is that the long tail is a hemodynamic artifact that has not been removed with the Off-ROI subtraction technique or is part of an intrinsic hemodynamic response. However, due to the prevalence of this long tail in other published sensors,20,23 it is likely that the prolonged fluorescence response represents prolonged excitation caused by a strong sensory stimulus. These data suggest that at the least the average ArcLight signal represents the average fast transients present in the LFP.
In addition to comparing the mean LFP and ArcLight response, we determined how well the ArcLight signal captured the single-trial LFP response [Figs. 4(d)–4(e), whiskers, across 2 mice, 100 trials each]. In a single trial, we measured the correlation between the ongoing LFP signal and the resulting ArcLight fluorescent response. We found that the spontaneous LFP and ArcLight responses were only weakly correlated periods of quiescence, Fig. 4(d), [maximum average Pearson coefficient spontaneous: 0.076 () at 35 ms poststimulus], that was significantly different compared to a trial shuffled case [mean Pearson correlation shuffled spontaneous, 0.002 (), , unpaired Student- test]. Although the single-trial correlation between LFP and ArcLight is low, these results are consistent with the weakly correlated single-trial LFP and similar wide-field voltage sensitive imaging techniques.33 During stimulation periods, Fig. 4(e), we also found that the LFP and the ArcLight were slightly more correlated [mean Pearson correlation stimulus: 0.22 (), temporal lag of 35 ms], shown in Fig. 4(e) (red trace). However, when we shuffled the trials to determine the correlative effects from the input, the correlation between shuffled and unshuffled signals was very similar [mean Pearson correlation shuffled stimulus: 0.13 (), , unpaired -test], suggesting that the correlation observed during stimulation was predominantly associated with the strong evoked response.
Instead of simply correlating the entire signal, we focused our analysis on determining if the LFP signal and the ArcLight evoked stimulus response amplitudes covaried. Here, we define the single-trial response amplitude as the difference in activity between the signal preceding the stimulus and maximum response within a 20-ms window during each imaging session’s peak response [Fig. 4(f)]. By limiting the analysis to the evoked peaks, we determined that the evoked response amplitudes between the two signals were correlated [mean Pearson correlation amplitude: 0.29 ()]. Moreover, when we shuffled the trials, this correlation between the response amplitudes disappeared [mean Pearson correlation shuffled amplitude: (), , unpaired -test]. These data suggest that the ArcLight and LFP amplitudes weakly covary in response to a sensory input. Taken together, these results suggest that ArcLight has the capacity to capture evoked features similar to evoked LFP and potentially provides additional information on ongoing cortical processes.
3.6. ArcLight Cortical Response to Complex Stimuli
Given the relatively long decay of the signal as measured by ArcLight in response to a single punctate sensory stimulus, this naturally begs the question as to the nature of the response to more complex inputs. To determine the temporal capabilities of ArcLight to represent complex stimuli, we presented a range of inputs to the whisker and recorded the downstream evoked cortical fluorescent response. We selected complex inputs that have been commonly used in the rodent vibrissa system,39,49–52 and therefore, these stimuli represent an additional comparison to published traditional electrophysiological recordings. Again, mice were anesthetized under low isoflurane (Sec. 2) and stimulated using a high-fidelity galvanometer device on a single whisker 10 mm from the face. We presented a range of sensory inputs from a simple ramp-and-hold53,54 to pulsatile frequency deflections (2.5 to 40 Hz) and recorded the evoked ArcLight response [Fig. 5(a), whiskers, across 2 animals]. Each trace represents the average response (100 trials per animal, 3 animals) within a single ROI taken as the maximal response 25 ms after stimulus presentation. In response to the ramp-and-hold stimulus, the cortical ArcLight response shows two clear peaks of activity corresponding to the rising (ON) and falling (OFF) stimulus events [Fig. 5(a), panel 1]. The two ON and OFF sensory peaks are representative of a well-documented velocity sensitivity of the rodent whisker somatosensory pathway.30,39,53 Additionally, we found that ArcLight S1 cortical responses clearly resolved repetitive frequency-dependent inputs between the ranges of 2.5 to 20 Hz [Fig. 5(a), panels 2 to 5], with evoked peaks of activity corresponding to the presented sensory stimulus. However, high-frequency [Fig. 5(a), panel 6, 40 Hz] deflections produced an overall increase in fluorescence that failed to clearly follow the sensory input. These results are summarized in Fig. 5(b), showing the amplitude of the peak ArcLight response as a function of stimulus frequency. The high-frequency 40-Hz stimulation is at the upper limit of the innate capabilities of ArcLight based on in vitro studies.2 These in vitro ArcLight experiments demonstrate fast temporal dynamics with a 10- to 20-ms rise time,12,18 and decay, which limits the fluorophore’s ability to represent high-frequency information greater than 40 Hz. Note that few studies have specifically examined the frequency encoding in mice under isoflurane anesthesia, so the limitations from a coding perspective are presently unclear. Taken together, these data demonstrate the use of ArcLight as a measurement of complex stimuli and frequency content in the S1 barrel cortex and highlight the potential limitations to resolve high-frequency information.
3.7. Stability and Variability of ArcLight as a Measure of Cortical Response
One critical component of any imaging fluorophore is the stability of the observed response over time. Our goal was to determine if the ArcLight cortical response dramatically changed during a long imaging experiment with continuous excitation. In a single trial, we would expect differences in activation of the barrel cortex due to various sources of neural variability;55,56 however, the average response over many trials will ideally remain relatively consistent during each experiment. Here, we analyzed the single-trial evoked sensory response during an imaging session after removing the shared hemodynamic signal using the post hoc Off-ROI subtraction method. Figure 6(a) shows the peak response frame averaged across trials for a single whisker deflection. For this analysis, we limited our investigation of stability to the temporal component of the main ROI of a single mouse barrel [Fig. 6(a), red square, ]. For the outlined ROI, Fig. 6(b) shows the time series of fluorescence on a trial-by-trial basis over 102 trials. Notice, on single trial there is trial-to-trial variability [Fig. 6(b): 102 trials, Fig. 6(c), top: 25 sequential trials]. However, when we average over blocks of 25 trials, the evoked signals appear to be quite similar, shown in Fig. 6(c), bottom.
We evaluated the stability within an imaging experiment by measuring the resulting distribution of responses within blocks of 25 sequential trials (). In this analysis, we included only one (the first) imaging experiment from each animal () to avoid skewing the results with data from a single mouse. Each experiment was normalized to the mean peak response for comparisons across animals. Specifically, we measured the peak response amplitude within a 20-ms window [Fig. 6(d), left]. We compared the resulting distributions of single-trial response amplitudes between the first trial block (), and last trial block () of the experiment across each animal [Fig. 6(d), right]. We found that within all experiments (7 mice) the difference between single-trial response amplitudes between the first and last 25 trial blocks were statistically insignificant [Fig. 6(d), right, , paired -test]. These results suggest that across the entire imaging experiment the peak response amplitude remained highly consistent.
In addition to the stability of the ArcLight response, we also determined the within experiment variability of the evoked response, regardless of any temporal drift. Similar to published VSD recordings,57 ArcLight exhibited high variability in fluorescent responses to a simple stimulus, shown as a 25-trial example in Fig. 6(c) (102 trials, 1 animal). We used the methods described above and averaged the fluorescent response across a moving 25-trial window to track parameters over time. We found that the within-experiment ArcLight response amplitude varied by 12.2% [ across 7 mice], measured as the standard deviation across an entire imaging experiment. These data suggest that the ArcLight cortical response is relatively stable across a long imaging experiment and exhibit variability that is consistent with other measurement modalities.
3.8. Repeatability of ArcLight Recording over Multiple Days
One of the great benefits of genetically expressed voltage probes is the ability to record from an animal over many days, weeks, and months. Repeatedly imaging over many days dramatically increases the data gained from a single animal, which may be of particular importance for behavioral experiments where mice need to be trained over weeks or months. To test the repeatability of the ArcLight response, we recorded the evoked fluorescence to the deflection of the same single whisker over a series of days (1, 3, 5, 7, 14, 21, 28). Each imaging experiment lasted to 2 h. We controlled isoflurane levels through constant measurement of physiological parameters (mainly heart rate, see Sec. 2.8) to minimize effects of different depths of anesthesia across days. Furthermore, we always attempted to stimulate the same whisker across imaging experiments. During one imaging experiment (mouse 2, day 14), the animal’s target whisker was not present, and therefore, we imaged the response to a different whisker in this isolated case.
We found that we were able to record the evoked responses over the course of 28 days [Fig. 7(a), mice]. After 28 days, the fluorescence response was still clearly visible, suggesting additional time-points could continue. Over the course of a month, the resulting spatial [Figs. 7(a) and 7(d)] and temporal dynamics [Fig. 7(b)] were consistent within an animal across days to weeks. Across all experiments, we found that the peak response amplitude (measured as normalized to day 1 ) was relatively consistent during repeated imaging sessions [mean response amplitude: SD% Norm , mice over 7 imaging sessions]. Furthermore, we found that the response amplitude variability across sessions in the same mouse was slightly less than the observed variability across different mice, but greater than the variability within an imaging session (amplitude SD same mouse: 18.3%, , amplitude SD across mice: 23%, , amplitude SD within session, 12.2%, ). Although we attempted to image under the same experimental conditions, the variability across days is expected to be higher than the within session variability due to slight changes in window quality, anesthesia level, and camera alignment. In order to assess the consistency of the spatial information, we compared the area of the evoked response across each day [Fig. 7(d)]. We measured the area of activation as the 50% contour of the peak response of the mean 25 to 35 ms poststimulus frames (Sec. 2). We found that the evoked cortical area to be relatively consistent across all repeated imaging experiment on the same whisker [mean area: 1.66 () , Fig. 7(d)]. The evoked area variability (SD) observed across repeated imaging experiments in the same mouse was less than the variability across mice and different whiskers (area SD across experiments same mouse: 21.0%, , area SD across mice, 41.4% ). These results suggest that repeatable imaging of ArcLight is consistent over the many weeks and months.
Above, we considered variability independent of possible trends across days; however, in order to determine potential drift, we compared the resulting distribution of single-trial responses between the first day, and final day of imaging [mean shown in Fig. 7(b) and 7(c)]. We determined that a majority of the animals () experienced insignificant differences between the 1st day and 28th day (, paired Wilcoxon signed-rank test) of imaging. Additionally, we found no clear trend in the evoked area of the evoked response [Fig. 7(d), shown as the square root of the area]. Here, the evoked area 25 to 35 ms poststimulus in mouse 2 slightly increased, in mouse 3 slightly decreased, and in mouse 1 remained constant. Even under extreme care, it is difficult to definitively determine the origin of the change in evoked fluorescence considering the many different parameters including window quality, experiment prep, and anesthesia level across imaging experiments and across mice. Therefore, it is unclear whether this change in evoked response is due to changes of the fluorophore (and expression) over time. Taken together, the above results demonstrate the capabilities of ArcLight to capture spatial and temporal information over many weeks and months. However, based on the day-to-day variability, careful analysis must be conducted when comparing and combining responses across days.
In addition to the evoked response amplitude, we determined if temporal dynamics remained consistent across many days of imaging. As shown in a subset of days [Fig. 7(b)], the temporal dynamics appear to be highly consistent across imaging experiments. We measured the Pearson correlation coefficient (PCC) across each imaging experiment to determine the changes in temporal waveform of activation. Here, we found the PCC to be highly correlated across imaging days mean . In some imaging experiments, slight changes in evoked response did occur, particularly poststimulus in the presence or absence of the secondary activation. However, the overall high correlation between evoked waveforms across weeks of imaging suggests that under highly controlled conditions, the same whisker stimulation produces very similar temporal activation.
3.9. Awake Recordings of Evoked ArcLight Mean and Single-Trial Responses
Finally, our goal was to determine if ArcLight had the capacity to represent cortical sensory responses in the awake rodent. Although previous studies have shown awake response of ArcLight, these examples were in either different species (Drosophila) or systems (mouse olfactory bulb), which would not guarantee clear fluorescent responses in cortical structures. Again, mice were left to express for four weeks before imaging (see Sec. 2.9). Mice were habituated over a period of three days to withstand long sessions of headfixation (Sec. 2) but were not trained on any task. In order to prevent whiskers from slipping out of the whisker stimulator galvanometer, the device was placed 5 mm from the face. We applied a similar stimulus as shown in Fig. 2; however, the stimulus was adjusted for the adjusted distance to the face. We report that ArcLight reveals a robust sensory evoked response even under awake conditions in the S1 barrel cortex (Fig. 8). In Fig. 8, we have shown a representative sensory evoked S1 cortical response; however, we observed similar responses across imaging experiments (5 whiskers across 3 mice). In the awake animal, we observed a decrease in the evoked response with a corresponding decrease in the SNR (, ). During periods of no stimulus presented to the whisker, the average spatial and temporal responses were negligible, as expected [Fig. 8(a), top, Fig. 8(b)]. When the whisker was deflected with a , the evoked response showed clear spatial and temporal activity similar to the anesthetized case [Fig. 2, as compared Figs. 8(a) and 8(b), single trials shown in Fig. 8(c)]. Due to the high variability of the ArcLight response, we would need substantially more data to make additional comparisons to the anesthetized case, and goes beyond the scope of this work. Taken together, this work highlights the ability of ArcLight as a robust spatial and temporal measurement tool of ongoing neural activity.
4. Discussion
In this work, we examined the functional characteristics of the genetically expressed voltage indicator (GEVI) ArcLight through testing in the widely used rodent sensory whisker pathway. With recent advances in GEVIs, there is a large demand to determine the in vivo functional limitations and capabilities for each new voltage probe. Since the initial discovery and publication;1 to our knowledge, ArcLight has been predominantly adopted as a tool for neuroscience research in Drosophila14,15,16,58,59 and has not been widely utilized in mammals. Other FRET-based GEVIs such as Butterfly 1.2, and VSFP 2.3 have been shown to measure widefield cortical responses in vivo; however, the monochromatic fluorophore ArcLight has yet been tested in in vivo cortical systems. We found that ArcLight produced a robust fluorescent response in the S1 barrel cortex in the anesthetized and awake mouse at high temporal and spatial resolution. We intend for this work not only to exclusively highlight the promise of ArcLight as a technique but also to provide a roadmap and a set of criteria for future GEVIs to be tested before widespread use.
4.1. ArcLight Imaging as a Method for Measuring Cortical Activation on a Mesoscopic Scale
Here, we used wide-field imaging to capture changes in population dynamics across the S1 barrel cortex on a mesoscopic scale (tens of ). Wide-field imaging is an alternative imaging modality that enables high temporal resolution recording across large structures on the order of cortical columns.60,61 We found that ArcLight was able to provide clear and repeatable fluorescence responses spatially resolved at the level of a single cortical barrel on fast timescales (tens of ms, Figs. 2, 4, 6), which makes it well suited for investigations into sensory precepts.
One of the biggest concerns with wide-field imaging is the uncertainty of the origin of the neurological signal responsible for the recorded evoked fluorescence. Using GEVIs, such as ArcLight, we gain additional selectivity over traditional VSDs (e.g., RH1691) by specifically targeting only neuron membranes and avoiding the pharmacological effects of staining with dyes.62 In this work, we utilized the human synapsin 1 (hsyn1) promoter to express ArcLight in predominately layer and layer 5 neurons (Fig. 1). Additional genetic lines could reduce the uncertainty of expression to a single layer, or neuronal subtype, thereby increasing the utilization of GEVIs to measure specific in vivo circuit dynamics.
Similar to LFP, ECoG, and BOLD fMRI, the underlying neural correlate of the wide-field GEVI response represents a combination of electrophysiological sources. We directly compared simultaneous recordings of LFP and ArcLight fluorescence during sensory stimulation (Fig. 4) to determine the relationship between these two modalities. On average, the stimulus-evoked LFP and fluorescence were correlated with some differences in temporal dynamics. However, in a single trial, the ArcLight and LFP signals were weakly correlated even during large evoked sensory features. Although the single-trial relationships between these signals are weak, the results are similar to weak correlations found between LFP and VSD imaging.33 Furthermore, propagating waves of cortical activity traverse the cortical layers in complex patterns63 and may compound as dynamic signals in the in vivo fluorescent response that is not represented in the evoked LFP. Additionally, wide-field recorded ArcLight fluorescence is believed to represent a spatial measurement of neural membrane potential,1,18 which is fundamentally different from extracellularly recorded LFP. Furthermore, the relationship between the LFP and the membrane potential is quite complex (for review Ref. 45), with some work proposing that the LFP represents the first derivative of the ongoing membrane potential.47 However, this finding should be regarded with caution as the filtering properties have been shown to strongly influence the nature of the LFP and membrane potential relationship.48 In paired intracellular and LFP recording experiments, LFP explains only a limited amount of the signal variance in the membrane potential.46 Finally, due to the large hemodynamic noise in the raw single trial and the limitations of the Off-ROI subtraction technique, careful consideration must be taken when examining ArcLight single trials. Taken together, our results suggest that while there are aspects of the wide-field ArcLight imaging that reflect features of the LFP, the ArcLight fluorescence contains different and potentially additional information about cortical activation.
4.2. ArcLight Excitation Causes Substantial Hemodynamic Noise in Recordings
Hemodynamic noise is a known issue for in vivo imaging of fluorophores with blue-green excitation and emission19,42 due to the overlap with the absorption spectrum of hemoglobin. Most of the current GEVIs including ArcLight, Butterfly 1.2, and mNeon-Ace8 all share blue-green excitation and emission wavelengths that cause tremendous noise for in vivo imaging. GEVIs based on FRET voltage probes, including Butterfly VSFP 2.1, have advantages in in vivo systems due to the ratiometric approach of the two fluorescence signals, which allows direct subtraction of a scaled hemodynamic signal. However, even these ratiometric approaches still require additional post hoc analysis to remove the properly scaled hemodynamic components from the recorded signals, which has been shown to be a nontrivial issue.19,64 For the non-FRET-based imaging methodology of ArcLight, we found that the ongoing hemodynamic noise required additional post hoc processing through Off-ROI subtraction to gain access to single-trial responses in the S1 cortex of the anesthetized mouse.
4.3. Limitations of the Off-ROI Subtraction Method as a Tool for Removing Hemodynamic Noise
Throughout this work, we implemented a scaled Off-ROI subtraction method to improve our ArcLight response and reduce ongoing hemodynamic noise, similar to techniques employed traditionally in processing in vivo wide-field imaging responses in voltage sensitive recording.33,43,62,65,66 However, this technique has several assumptions and limitations. By scaling and subtracting an Off-ROI region, we are making general assumptions about the shared dynamics of the noise spatially across the image. While this Off-ROI subtraction method does have success in removing temporal hemodynamic noise, careful considerations must be taken for spatial information, especially in locations far from the ROI. Additionally, the general assumption is that the observed signal of interest is spatially confined, and care should be taken for signals not confined to a particular brain region. We compared the mean of the raw data and the postprocessed ROI subtracted obtained similar spatial signals (Fig. 11). Additionally, similar to other reference methods,43,67 we are subtracting shared information, which may include spatiotemporal brain states, or evoked responses. To avoid these issues, we defined a 1-mm radius, which separates our ROI and the model template. This assumption is region specific to the S1 mouse barrel cortex, and therefore, must be adapted based on anatomy and functional responses. Overall, the methods described here detail the basis of a general model for subtracting common noise; however, there is a demand for better techniques for removing hemodynamic noise from spectrally overlapped excitation wavelengths. Furthermore, future development of brighter and more redshifted GEVIs will greatly reduce the hemodynamic influence in the recorded fluorescence signal.
4.4. Comparison of ArcLight Cortical Responses to Previously Reported Voltage Sensors
In this work, we focused on the performance of ArcLight to reflect the spatial and temporal evoked response in the S1 barrel cortex. Although we did not directly compare ArcLight to other GEVIs, the whisker evoked fluorescence responses are within the range of the published temporal dynamics of voltage sensitive indicators in similar preparations.20,21,23 Very few studies have conducted cortical recordings using the same preparations described in this work; therefore, a direct comparison between GEVIs remains difficult. However, certain features of the mesoscopic whisker evoked S1 cortical response are consistent across imaging sensors and probes. We observed a strong sensory driven cortical response that produced fluorescence changes similar to other GEVIs (VSFP Butterfly 1.2 and VSFP 2.3) and VSDs (RH1691). These features include a sharp rising transient event lasting to 50 ms,20,21,23 and a longer tail that follows the response and decays over a period of a few hundreds of milliseconds.3,23 Additionally, the average evoked response SNR for ArcLight was similar to other GEVIs; however, in a single trial, the SNR was substantially worse which required the post hoc Off-ROI subtraction method to recover these signals. We observed that ArcLight was able to represent content only up to whisker stimulation; however, how much of this limitation is due to the imaging modality versus the dynamics of the pathway is unclear. Other FRET-based sensors have also reported frequencies of up to 20 Hz to sensory stimuli in other systems using similar techniques.19,68 Recently developed GEVIs including ASAP1,69 Ace-mNeon,6 Mac-mCitrine,70 and Quasar1 report higher temporal resolution; however, most of these voltage probes have not yet been fully tested in vivo. We found ArcLight imaging had a slow rate of photobleaching with consistent responses recorded over a duration of of uninterrupted imaging (Fig. 3). Currently, there is no perfect GEVI that combines dynamic fluorescence range, photostability, large signals, and fast temporal dynamics. The results of this work suggest that ArcLight is capable of reporting sensory evoked responses in the cortex and can be used chronically to measure over many days to weeks.
4.5. Future Applications of ArcLight and GEVI Imaging
In summary, this work has demonstrated the potential use of the GEVI ArcLight as an in vivo method for investigating cortical circuits on a mesoscopic scale in the awake and anesthetized animal. GEVIs in general show tremendous promise in providing voltage measurements from small networks of cells simultaneously that can be selected based on genetic markers and have the potential to ultimately offer single cell resolution. Like the many variants of opsins used, each study should select the proper GEVI for that particular work. ArcLight is a single example that provides a clear and reliable response to sensory stimuli in the sensory cortex, and we speculate would be ideal for behavioral experiments that require long imaging sessions. However, due to the potentially largely hemodynamic noise caused by the spectral overlap with hemoglobin, the user must take special precautions to remove this noise. Here, we utilized a scaled Off-ROI method that may not be applicable for all studies. Based on our results, ArcLight would be well-suited for in vivo experiments where a single fluorophore is desired, for example, during paired optogenetics or multispectral imaging of multiple cell types. Moreover, the true advantage of using a GEVI such as ArcLight is the ability to record the evoked response over the course of months and in the awake animal. Here, we found that both awake and repeated imaging experiments are feasible using the ArcLight voltage sensor. Future work is clearly needed to optimize the imaging and analytical techniques of these sensitive fluorescent probes.
Acknowledgments
This paper was supported by the National Institute of Neurological Disorders and Stroke (NINDS): Award Nos. R01NS48285 (PI: G.B. Stanley), R01NS085447 (PI: G.B. Stanley), U01NS094302 (PI: D. Jaeger, and G.B. Stanley), and NS09869 (PI: P.Y. Borden); National Institute of Mental Health (NIMH): Award No. U01MH106027 (PI: G.B. Stanley, C.R. Forest). The authors would like to thank William Stoy, Ilya Kolb, and Timothy Lee, as well as other members of the Precision Biosystems Lab at Georgia Tech, for additional support and advice on imaging. Additionally, we thank Kyle Blum for feedback on imaging analysis and illustrations. We would also like to acknowledge He Zheng for pilot work on the ArcLight imaging. Furthermore, we would like to thank Vincent A. Pieribone for supplying us with the initial ArcLight protein and for imaging advice.
Biographies
Peter Y. Borden received his BSE degree in bioengineering from Rice University in 2008. He is currently a doctoral student at Georgia Institute of Technology and Emory University in the joint Biomedical Engineering Graduate Program. His current research aims to understand thalamocortical processing related to sensory processing.
Alex D. Ortiz received his bachelor of science degree in biochemistry from Tulane University in 2006 and his master of business administration from Georgia Institute of Technology in 2016. He has been a research associate in the Department of Biomedical Engineering at Georgia Institute of Technology since 2009.
Christian Waiblinger received his PhD in neuroscience from Werner Reichardt Centre for Integrative Neuroscience Systems Neurophysiology in 2015. He is currently a postdoctoral fellow at the Georgia Institute of Technology. His research focuses on understanding cortical and thalamic sensory processing during behavior.
Audrey J. Sederberg received her PhD in physics from Princeton University in 2011. She is currently a postdoctoral fellow at the Georgia Institute of Technology. Her research focuses on understanding the role of cortical state on sensory processing.
Arthur E. Morrissette received his BS degree in biomedical engineering from Georgia Institute of Technology in 2013. Since then, he has been a doctoral student at Emory University in the Neuroscience Graduate Program. His current research aims to understand cortical and basal ganglia processing related to sensorimotor control.
Craig R. Forest is an associate professor of mechanical engineering at Georgia Tech, where he also holds program faculty positions in bioengineering and biomedical engineering. He was a fellow at the Allen Brain Institute, Seattle, Washington, USA, and he is one of the inaugural recipients of the NIH BRAIN Initiative Grants, a national research effort to invent the next generation of neuroscience and neuroengineering tools.
Dieter Jaeger’s research combines cellular and systems electrophysiological recordings from rodents with detailed computer modeling to examine how neurons in the basal ganglia and in the cerebellum process their inputs. Of particular interest is the function of inhibition and of active neural properties in network processing. The ultimate goal is to understand the motor function of basal ganglia and cerebellar networks during behavior in normal and disease states.
Garrett B. Stanley received his PhD from the University of California, Berkeley, in mechanical engineering with postdoctoral work in neuroscience in the Department of Molecular and Cellular Biology at Berkeley. He is the Carol Ann and David D. Flanagan professor in the Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University. The work of his laboratory focuses on information processing in sensory pathways, with an emphasis on the thalamocortical circuit.
Appendix.
A1. Removal of Hemodynamic Frequency using Notch Filtering
Due to the hemodynamic noise found in the captured fluorescence signal (Fig. 3), our first approach for removing the noise was a simple common notch filter at the hemodynamic frequencies (main and corresponding first harmonic). We found that the hemodynamic signal we observed was correlated with the ongoing heart rate of the animal (Fig. 3) between and 10 Hz, which corresponds to a heart rate between 300 and 600 bpm. This estimated heart rate range matches the typical physiological heart rate of an anesthetized mouse. Two examples (Fig. 9) are of ArcLight evoked sensory responses and the corresponding power spectral density of the evoked fluorescence with and without notch filtering (second-order Butterworth, bandstop between 5 and 20 Hz). We found that due to the total event time of the ArcLight response ( to 300 ms), simple notch filtering at 5 to 20 Hz would greatly disrupt the ArcLight waveform.
A2. Removal of Hemodynamic Frequency Using Off-ROI Subtraction Methods
Throughout this work, we utilized an Off-ROI to subtract ongoing hemodynamic noise observed in the fluorescence signal. This Off-ROI technique utilized the highly correlated structure of the hemodynamic signal through the cortical tissue to subtract common noise. Two figures detail the removal of the hemodynamic noise through the Off-ROI subtraction (Fig. 10) and the effect of the Off-ROI placement on the spatiotemporal response (Fig. 11).
A3. Noninjected ArcLight Control
To confirm that any effects of autofluorescence do not significantly affect our results, we conducted additional experiments examining a noninjected animal to determine the potential influence of the intrinsic autofluorescence on the spatial extent of the response. First, we mapped the S1 barrel cortex using intrinsic imaging (see Sec. 2.4) to determine the proper location of the corresponding whisker sensitive cortical region. Due to the slow temporal dynamics and overall small change in signal, we measured the intrinsic response to a repetitive stimulus over several seconds. Figure 12(a) shows a temporal average (across 20 trials) of the intrinsic response in a time window of 1 to 2 s after the onset of the strong repetitive whisker stimulation ( at 10 Hz for 5 s).
After we mapped the region using the intrinsic signal, we set up the system for ArcLight imaging described in detail in this paper and applied the same single whisker punctate stimuli used in a majority of the study [single sawtooth () stimulus]. In Fig. 12(b), we compared the intrinsically identified whisker region [Fig. 12(a)] to responses using the ArcLight setup and experimental parameters used throughout this work. Specifically, we sampled the same area at 200 Hz with blue excitation (465 nm) along with the excitation and emission filters as described in Sec. 2. Figure 12(b, left) shows the averaged spatial response over the 700-ms window poststimulus (100 trials), with no apparent qualitative difference between the identified ROI (red) and other Off-ROIs (blue and aqua). The 700-ms window corresponds to the approximate length of the average S1 cortical response used throughout this paper [Fig. 2(c)]. Figure 12(b, right) shows the time series of integrated activity within these ROIs. We found no quantitative difference between the evoked response in the identified (red) ROI and the background, prestimulus activity, indicating that there was no appreciable evoked response. [E1: mean prestimulus fluorescence ( to 0 ms) , mean poststimulus fluorescence (0 to 700 ms) , , , paired -test].
In the noninjected mouse, in the ArcLight setup [Fig. 12(b)], we also observe oscillatory responses (8 to 10 Hz) across both whiskers similar to the observed hemodynamic signal in the single-trial responses, shown in Fig. 3. These hemodynamic oscillations can still be seen in the C2 and E1 trial average in Fig. 12(b). These results further suggest that this oscillatory signal is not representative of ongoing membrane potential fluctuations but is due to the blood flow across the cortical surface. Based on these controls, we expect that the observed stimulus evoked fluorescence response shown throughout our study is most likely due to the changes in neural activity associated with ArcLight and not due to autofluorescence.
Disclosures
The authors declare no competing financial interests.
References
- 1.Jin L., et al. , “Single action potentials and subthreshold electrical events imaged in neurons with a fluorescent protein voltage probe,” Neuron 75(5), 779–785 (2012). 10.1016/j.neuron.2012.06.040 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Cao G., et al. , “Genetically targeted optical electrophysiology in intact neural circuits,” Cell 154(4), 904–913 (2013). 10.1016/j.cell.2013.07.027 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Akemann W., et al. , “Imaging brain electric signals with genetically targeted voltage-sensitive fluorescent proteins,” Nat. Methods 7(8), 643–649 (2010). 10.1038/nmeth.1479 [DOI] [PubMed] [Google Scholar]
- 4.Akemann W., et al. , “Imaging neural circuit dynamics with a voltage-sensitive fluorescent protein,” J. Neurophysiol. 108(8), 2323–2337 (2012). 10.1152/jn.00452.2012 [DOI] [PubMed] [Google Scholar]
- 5.Hochbaum D. R., et al. , “All-optical electrophysiology in mammalian neurons using engineered microbial rhodopsins,” Nat. Methods 11(8), 825–833 (2014). 10.1038/nmeth.3000 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Gong Y., et al. , “High-speed recording of neural spikes in awake mice and flies with a fluorescent voltage sensor,” Science 350(6266), 1361–1366 (2015). 10.1126/science.aab0810 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Nakajima R., et al. , “Optogenetic monitoring of synaptic activity with genetically encoded voltage indicators,” Front. Synaptic Neurosci. 8, 1–9 (2016). 10.3389/fnsyn.2016.00022 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Storace D., et al. , “Toward better genetically encoded sensors of membrane potential,” Trends Neurosci. 39(5), 277–289 (2016). 10.1016/j.tins.2016.02.005 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Knöpfel T., Gallero-Salas Y., Song C., “Genetically encoded voltage indicators for large scale cortical imaging come of age,” Curr. Opin. Chem. Biol. 27, 75–83 (2015). 10.1016/j.cbpa.2015.06.006 [DOI] [PubMed] [Google Scholar]
- 10.Lin M. Z., Schnitzer M. J., “Genetically encoded indicators of neuronal activity,” Nat. Neurosci. 19(9), 1142–1153 (2016). 10.1038/nn.4359 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Antic S. D., Empson R. M., Knopfel T., “Voltage imaging to understand connections and functions of neuronal circuits,” J. Neurophysiol. 116, 135–152 (2016). 10.1152/jn.00226.2016 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Han Z., et al. , “Mechanistic studies of the genetically encoded fluorescent protein voltage probe ArcLight,” PLoS One 9(11), e113873 (2014). 10.1371/journal.pone.0113873 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Brinks D., Klein A. J., Cohen A. E., “Two-photon lifetime imaging of voltage indicating proteins as a probe of absolute membrane voltage,” Biophys. J. 109(5), 914–921 (2015). 10.1016/j.bpj.2015.07.038 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Sitaraman D., et al. , “Propagation of homeostatic sleep signals by segregated synaptic microcircuits of the Drosophila mushroom body,” Curr. Biol. 25(22), 2915–2927 (2015). 10.1016/j.cub.2015.09.017 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Raccuglia D., et al. , “Presynaptic GABA receptors mediate temporal contrast enhancement in Drosophila olfactory sensory neurons and modulate odor-driven behavioral kinetics,” eNeuro 3(4) (2016). 10.1523/ENEURO.0080-16.2016 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Klein M., et al. , “Sensory determinants of behavioral dynamics in Drosophila thermotaxis,” Proc. Natl. Acad. Sci. 112(2), E220–E229 (2015). 10.1073/pnas.1416212112 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Klapoetke N. C., et al. , “Independent optical excitation of distinct neural populations,” Nat. Methods 11(3), 338–346 (2014). 10.1038/nmeth.2836 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Storace D. A., et al. , “Monitoring brain activity with protein voltage and calcium sensors,” Sci. Rep. 5, 10212 (2015). 10.1038/srep10212 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Carandini M., et al. , “Imaging the awake visual cortex with a genetically encoded voltage indicator,” J. Neurosci. 35(1), 53–63 (2015). 10.1523/JNEUROSCI.0594-14.2015 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Civillico E. F., Contreras D., “Integration of evoked responses in supragranular cortex studied with optical recordings in vivo,” J. Neurophysiol. 96(1), 336–351 (2006). 10.1152/jn.00128.2006 [DOI] [PubMed] [Google Scholar]
- 21.Ferezou I., Bolea S., Petersen C. C. H., “Visualizing the cortical representation of whisker touch: voltage-sensitive dye imaging in freely moving mice,” Neuron 50(4), 617–629 (2006). 10.1016/j.neuron.2006.03.043 [DOI] [PubMed] [Google Scholar]
- 22.Ferezou I., et al. , “Spatiotemporal dynamics of cortical sensorimotor integration in behaving mice,” Neuron 56(5), 907–923 (2007). 10.1016/j.neuron.2007.10.007 [DOI] [PubMed] [Google Scholar]
- 23.Mutoh H., et al. , “Comparative performance of a genetically-encoded voltage indicator and a blue voltage sensitive dye for large scale cortical voltage imaging,” Front. Cell. Neurosci. 9, 147 (2015). 10.3389/fncel.2015.00147 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Wang Q., Webber R. M., Stanley G. B., “Thalamic synchrony and the adaptive gating of information flow to cortex,” Nat. Neurosci. 13(12), 1534–1541 (2010). 10.1038/nn.2670 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Razali N. M., Wah Y. B., “Power comparisons of Shapiro–Wilk, Kolmogorov–Smirnov, Lilliefors and Anderson–Darling tests,” J. Stat. Model. Anal. 2(1), 21–33 (2011). [Google Scholar]
- 26.Lütcke H., et al. , “Optical recording of neuronal activity with a genetically-encoded calcium indicator in anesthetized and freely moving mice,” Front. Neural Circuits 4, 9 (2010). 10.3389/fncir.2010.00009 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Han Z., et al. , “Fluorescent protein voltage probes derived from ArcLight that respond to membrane voltage changes with fast kinetics,” PLoS One 8(11), e81295 (2013). 10.1371/journal.pone.0081295 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Gollnick C. A., et al. , “Response reliability observed with voltage-sensitive dye imaging of cortical layer : the probability of activation hypothesis,” J. Neurophysiol. 115(5), 2456–2469 (2016). 10.1152/jn.00547.2015 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Stüttgen M. C., Schwarz C., “Psychophysical and neurometric detection performance under stimulus uncertainty,” Nat. Neurosci. 11(9), 1091–1099 (2008). 10.1038/nn.2162 [DOI] [PubMed] [Google Scholar]
- 30.Shoykhet M., Doherty D., Simons D. J., “Coding of deflection velocity and amplitude by whisker primary afferent neurons: implications for higher level processing,” Somatosens. Mot. Res. 17(2), 171–180 (2009). 10.1080/08990220050020580 [DOI] [PubMed] [Google Scholar]
- 31.Wolfe J., et al. , “Texture coding in the rat whisker system: slip-stick versus differential resonance,” PLoS Biol. 6(8), e215 (2008). 10.1371/journal.pbio.0060215 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Petersen C. C. H., Grinvald A., Sakmann B., “Spatiotemporal dynamics of sensory responses in layer of rat barrel cortex measured in vivo by voltage-sensitive dye imaging combined with whole-cell voltage recordings and neuron reconstructions,” J. Neurosci. 23(4), 1298–1309 (2003). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Lippert M. T., et al. , “Methods for voltage-sensitive dye imaging of rat cortical activity with high signal-to-noise ratio,” J. Neurophysiol. 98(1), 502–512 (2007). 10.1152/jn.01169.2006 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Wang Q., et al. , “Erratum: voltage-sensitive dye imaging reveals improved topographic activation of cortex in response to manipulation of thalamic microstimulation parameters,” J. Neural Eng. 9(5), 59601 (2012). 10.1088/1741-2560/9/5/059601 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Millard D. C., Wang Q., Stanley G. B., “Nonlinear system identification of the thalamocortical circuit in response to thalamic microstimulation,” in 2011 5th Int. IEEE/EMBS Conf. Neural Engineering (NER 2011) (2011). 10.1109/NER.2011.5910475 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Welker E., Van der Loos H., “Quantitative correlation between barrel-field size and the sensory innervation of the whiskerpad: a comparative study in six strains of mice bred for different patterns of mystacial vibrissae,” J. Neurosci. 6(11), 3355–3373 (1986). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Woolsey T. A., Wann J. R., “Areal changes in mouse cortical barrels following vibrissal damage at different postnatal ages,” J. Comp. Neurol. 170(1), 53–66 (1976). 10.1002/(ISSN)1096-9861 [DOI] [PubMed] [Google Scholar]
- 38.Ramirez A., et al. , “Spatiotemporal receptive fields of barrel cortex revealed by reverse correlation of synaptic input,” Nat. Neurosci. 17(6), 866–875 (2014). 10.1038/nn.3720 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Kwegyir-Afful E. E., Kyriazi H. T., Simons D. J., “Weaker feedforward inhibition accounts for less pronounced thalamocortical response transformation in mouse vs. rat barrels,” J. Neurophysiol. 110(10), 2378–2392 (2013). 10.1152/jn.00574.2012 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Kleinfeld D., Delaney K. R., “Distributed representation of vibrissa movement in the upper layers of somatosensory cortex revealed with voltage-sensitive dyes,” J. Comp. Neurol. 375(1), 89–108 (1996). 10.1002/(ISSN)1096-9861 [DOI] [PubMed] [Google Scholar]
- 41.Jia H., et al. , “In vivo two-photon imaging of sensory-evoked dendritic calcium signals in cortical neurons,” Nat. Protoc. 6(1), 28–35 (2010). 10.1038/nprot.2010.169 [DOI] [PubMed] [Google Scholar]
- 42.Hillman E. M. C., “Optical brain imaging in vivo: techniques and applications from animal to man,” J. Biomed. Opt. 12(5), 051402 (2007). 10.1117/1.2789693 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Raguet H., et al. , “Spatially structured sparse morphological component separation for voltage-sensitive dye optical imaging,” J. Neurosci. Methods 257, 76–96 (2016). 10.1016/j.jneumeth.2015.09.024 [DOI] [PubMed] [Google Scholar]
- 44.Al-Juboori S. I., et al. , “Light scattering properties vary across different regions of the adult mouse brain,” PLoS One 8(7), e67626 (2013). 10.1371/journal.pone.0067626 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Buzsáki G., Anastassiou C. A., Koch C., “The origin of extracellular fields and currents—EEG, ECoG, LFP and spikes,” Nat. Rev. Neurosci. 13(6), 407–420 (2012). 10.1038/nrn3241 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Haider B., et al. , “Millisecond coupling of local field potentials to synaptic currents in the awake visual cortex,” Neuron 90(1), 35–42 (2016). 10.1016/j.neuron.2016.02.034 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Okun M., Naim A., Lampl I., “The subthreshold relation between cortical local field potential and neuronal firing unveiled by intracellular recordings in awake rats,” J. Neurosci. 30(12), 4440–4448 (2010). 10.1523/JNEUROSCI.5062-09.2010 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Okun M., “Artefactual origin of biphasic cortical spike-LFP correlation,” J. Comput. Neurosci. 42(1), 31–35 (2017). 10.1007/s10827-016-0625-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Khatri V., Bruno R. M., Simons D. J., “Stimulus-specific and stimulus-nonspecific firing synchrony and its modulation by sensory adaptation in the whisker-to-barrel pathway,” J. Neurophysiol. 101(5), 2328–2338 (2009). 10.1152/jn.91151.2008 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Khatri V., “Adaptation in thalamic barreloid and cortical barrel neurons to periodic whisker deflections varying in frequency and velocity,” J. Neurophysiol. 92(6), 3244–3254 (2004). 10.1152/jn.00257.2004 [DOI] [PubMed] [Google Scholar]
- 51.Webber R. M., Stanley G. B., “Nonlinear encoding of tactile patterns in the barrel cortex,” J. Neurophysiol. 91(5), 2010–2022 (2004). 10.1152/jn.00906.2003 [DOI] [PubMed] [Google Scholar]
- 52.Boloori A., Jenks R. A., Stanley G. B., “Encoding and decoding cortical representations of tactile features in the vibrissa system,” J. Neurosci. 30, 9990–10005 (2010). 10.1523/JNEUROSCI.0807-10.2010 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Kyriazi H. T., Carvell G. E., Simons D. J., “OFF response transformations in the whisker/barrel system,” J. Neurophysiol. 72(1), 392–401 (1994). [DOI] [PubMed] [Google Scholar]
- 54.Kwegyir-Afful E. E., et al. , “The role of thalamic inputs in surround receptive fields of barrel neurons,” J. Neurosci. 25(25), 5926–5934 (2005). 10.1523/JNEUROSCI.1360-05.2005 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Anderson J., et al. , “Stimulus dependence of two-state fluctuations of membrane potential in cat visual cortex,” Nat. Neurosci. 3(6), 617–621 (2000). 10.1038/75797 [DOI] [PubMed] [Google Scholar]
- 56.Reich D. S., et al. , “Response variability and timing precision of neuronal spike trains in vivo,” J. Neurophysiol. 77(5), 2836–2841 (1997). [DOI] [PubMed] [Google Scholar]
- 57.Singla R. D., Wang J., Singla D. K., “Regulation of notch 1 signaling in THP-1 cells enhances macrophage differentiation,” Am. J. Physiol. Heart Circ. Physiol. 307(11), H1634 (2014). 10.1152/ajpheart.00896.2013 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Kallman B. R., Kim H., Scott K., “Excitation and inhibition onto central courtship neurons biases Drosophila mate choice,” Elife 4, e11188 (2015). 10.7554/eLife.11188 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Haynes P. R., Christmann B. L., Griffith L. C., “A single pair of neurons links sleep to memory consolidation in Drosophila melanogaster,” Elife 4, e03868 (2015). 10.7554/eLife.03868 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Shtoyerman E., et al. , “Long-term optical imaging and spectroscopy reveal mechanisms underlying the intrinsic signal and stability of cortical maps in V1 of behaving monkeys,” J. Neurosci. 20(21), 8111–8121 (2000). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Seidemann E., et al. , “Calcium imaging with genetically encoded indicators in behaving primates,” Elife 5, e16178 (2016). 10.7554/eLife.16178 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Grandy T. H., Greenfield S. A., Devonshire I. M., “An evaluation of in vivo voltage-sensitive dyes: pharmacological side effects and signal-to-noise ratios after effective removal of brain-pulsation artifacts,” J. Neurophysiol. 108, 2931–2945 (2012). 10.1152/jn.00512.2011 [DOI] [PubMed] [Google Scholar]
- 63.Reyes-Puerta V., et al. , “Propagation of spontaneous slow-wave activity across columns and layers of the adult rat barrel cortex in vivo,” Brain Struct. Funct. 221(9), 4429–4449 (2016). 10.1007/s00429-015-1173-x [DOI] [PubMed] [Google Scholar]
- 64.Wilt B. A., et al. , “Photon shot noise limits on optical detection of neuronal spikes and estimation of spike timing,” Biophys. J. 104, 51–62 (2013). 10.1016/j.bpj.2012.07.058 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Arieli A., et al. , “Dynamics of ongoing activity: explanation of the large variability in evoked cortical responses,” Science 273(5283), 1868–1871 (1996). 10.1126/science.273.5283.1868 [DOI] [PubMed] [Google Scholar]
- 66.Grinvald A., et al. , “Cortical point-spread function and long-range lateral interactions revealed by real-time optical imaging of macaque monkey primary visual cortex,” J. Neurosci. 14, 2545–2568 (1994). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67.Ludwig K. A., et al. , “Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3, 4-ethylenedioxythiophene) (PEDOT) film,” J. Neural Eng. 3(1), 59–70 (2006). 10.1088/1741-2560/3/1/007 [DOI] [PubMed] [Google Scholar]
- 68.Madisen L., et al. , “Transgenic mice for intersectional targeting of neural sensors and effectors with high specificity and performance,” Neuron 85(5), 942–958 (2015). 10.1016/j.neuron.2015.02.022 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.St-Pierre F., et al. , “High-fidelity optical reporting of neuronal electrical activity with an ultrafast fluorescent voltage sensor,” Nat. Neurosci. 17(6), 884–889 (2014). 10.1038/nn.3709 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Gong Y., et al. , “Imaging neural spiking in brain tissue using FRET-opsin protein voltage sensors,” Nat. Commun. 5, 3674 (2014). 10.1038/ncomms4674 [DOI] [PMC free article] [PubMed] [Google Scholar]