Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2017 Apr 26;7:1181. doi: 10.1038/s41598-017-01277-3

Imaging of underground cavities with cosmic-ray muons from observations at Mt. Echia (Naples)

G Saracino 1,2,, L Amato 3, F Ambrosino 1,2, G Antonucci 3, L Bonechi 4, L Cimmino 2, L Consiglio 5, R D’ Alessandro 4,6, E De Luzio 7, G Minin 7, P Noli 2, L Scognamiglio 5, P Strolin 1,2, A Varriale 5
PMCID: PMC5430851  PMID: 28446789

Abstract

Muography is an imaging technique based on the measurement of absorption profiles for muons as they pass through rocks and earth. Muons are produced in the interactions of high-energy cosmic rays in the Earth’s atmosphere. The technique is conceptually similar to usual X-ray radiography, but with extended capabilities of investigating over much larger thicknesses of matter thanks to the penetrating power of high-energy muons. Over the centuries a complex system of cavities has been excavated in the yellow tuff of Mt. Echia, the site of the earliest settlement of the city of Naples in the 8th century BC. A new generation muon detector designed by us, was installed under a total rock overburden of about 40 metres. A 26 days pilot run provided about 14 millions of muon events. A comparison of the measured and expected muon fluxes improved the knowledge of the average rock density. The observation of known cavities proved the validity of the muographic technique. Hints on the existence of a so far unknown cavity was obtained. The success of the investigation reported here demonstrates the substantial progress of muography in underground imaging and is likely to open new avenues for its widespread utilisation.

Introduction

Muons are penetrating particles produced in Nature from the interactions of cosmic rays in the Earth’s atmosphere, with a spectrum extending to very high energies. These features allows us to extend the principle of standard X-ray radiography to the “muography” of very large thicknesses of matter (up to the order of 1 km of standard rock). Projective images of their density structure are provided through the determination of muon transmission, this in turn depends on the average densities and thicknesses of matter crossed by the muons.

To this purpose, the tracks of through-going muons are measured and the angular distribution of the reconstructed trajectories is compared to that expected in the absence of absorption, usually obtained from a dedicated data taking run with the detector pointing directly to the free sky. An expexted muon flux is then obtained from a map of the average density and traversed thicknesses as given by a Digital Terrain Model (DTM). A low density region, in particular a cavity, shows up in the data as an excess in the muon transmission.

The first steps in the field of muography occurred in 1955 with the determination of the rock overburden on a mountain tunnel from the measurement of the muon flux reduction1. In 1970 Louis Alvarez and collaborators performed a muography of the Chephren pyramid, searching for a hidden burial chamber2. The search was unsuccessful, but the feasibility of the technique was demonstrated. More recently the method has been applied in the study of the internal structure of volcanoes (see for example39 and references therein). Measurements or feasibility studies concerning muography applications in archaeology10, 11, mining12, tunnel searches13, 14, geological survey15 and nuclear waste detection16 have been reported in literature.

In the study reported here, the technique is used to investigate the underground cavities inside Mt. Echia in the city of Naples, with the additional aim of assessing its potentialities. The measurement was performed in the framework of the METROPOLIS project coordinated by STRESS S.c.a r.l. and was hosted by the cultural association Borbonica Sotteranea.

Mt. Echia (also called Pizzofalcone) hosted the ancient greek colony Parthenope founded in 8th century BC. That first settlement was subsequently called Palepolis (“old city”) when, in 5th century BC, its development led to the nearby foundation of Neapolis (“new city”) from which the denomination of Naples originates.

The DTM of Mt. Echia is shown in Figs 1 and 2. Mt. Echia mainly consists of yellow tuff, a soft volcanic rock and its maximum altitude is about 60 m asl. In the course of history a very complex system of underground tunnels and cavities was excavated which only recently has become subject of systematic investigations.

Figure 1.

Figure 1

Digital Terrain Model (DTM) of Mt. Echia, with a resolution of 1 m in the horizontal x-y coordinates and 10 cm in the vertical z coordinate. The detector is located at 10 m a.s.l. within the dashed square, in the neighbourhood of the Bourbon Tunnel (straight line). The main underground structures located in the surrounding area are schematically shown. The map has been obtained by LIDAR observations elaborated by the following softwares: Terrasolid - Terrascan, LP360, RIEGL Riscan Pro, Golden Software - Surfer 12 and root.

Figure 2.

Figure 2

Three dimensional representation of the Digital Terrain Model (DTM) of Mt. Echia. The image was obtained using LIDAR observations elaborated by the following softwares: Terrasolid - Terrascan, LP360, RIEGL Riscan Pro, Golden Software - Surfer 12 and root.

The underground cavities served an astonishing variety of purposes, e.g. including that of a mithraeum (until the cult of Mithra was banned at the end of the 4th century AD). The tuff has been widely used as construction material: typically, tuff bricks were extracted from underground through a pit and the resulting cavities were then used for other purposes (e.g. water cisterns). In 1853 under the kingdom of Ferdinand II of the Bourbon House - King of the Two Sicilies - the so-called Bourbon Tunnel (see Fig. 1) was excavated through Mt. Echia for the purpose of connecting directly the Royal Palace and the military quarters, located on the opposite side. The Bourbon Tunnel has been restored in recent times and inserted in one of the archaeological underground itineraries, which include a large number of underground structures that have been rediscovered thanks to the ongoing underground exploration of Mt. Echia.

The muon detector is shown in Fig. 3 and is described in the next section. It was accommodated in a small recess of a cavity containing an underground water cistern (Fig. 4) and connected to the Bourbon Tunnel (see Fig. 1), so that it was rather easily accessible. Above the detector there are known cavities, suitable for test the technique as a first step for possible further investigations.

Figure 3.

Figure 3

The detector in a recess of the cavity facing the water cistern.

Figure 4.

Figure 4

The water cistern, as seen from the detector location.

The muon detector

The muon detector is an upgraded version of the MU-RAY detector, developed for volcano muography1719. The main upgrades concern mechanics and the power supply system. Two MU-RAY half planes are assembled in a single aluminium shell together with the Front-End Electronics, forming a detection plane of about 1 m2 with handles installed that can be easily transported (see Fig. 5). The detection planes are mounted on the measurement site and the cabling is performed using few round-shape connectors. Also the electric power supply has been simplified and all the needed voltages, including the Silicon photomultipliers bias voltage, are produced by the front-end boards starting from a single 6 V supply.

Figure 5.

Figure 5

Left: Sketch of the aluminium shell of a detection plane, consisting in 64 scintillator bars and the Front-End Electronics. Right: Sketch of the muon telescope, consisting of a vertical sequence of three modules, mounted horizontally on a support (not shown) and evenly spaced in the vertical direction (z-axis).

The MU-RAY basic sensitive element to crossing muons are plastic scintillator bars of triangular cross-section.

Each bar has a length of 107 cm, a 3.3 cm base and a height of 1.7 cm. They are extruded with a central 2 mm hole through which a 1 mm diameter wavelength shifter fibres (BICRON BCF92) is threaded. The bars have a TiO 2 coating (0.25 mm thick) that increases the internal reflectivity and screens them from outside light sources20. The light signals produced by muons in the plastic scintillator bars are conveyed to photosensors by the fibres. The photosensors are based on the solid-state Silicon Photo-Multiplier (SiPM) technology, that allows for photo-electron counting. The photosensors are produced by Hamamatsu Photonics (MPPC S12825-050P). A detection plane consists of two half planes (each with 32 adjacent bars alternatively turned upside down) covering an area of about 1 m2. Each 32 fibre bundle is optically coupled to a printed circuit board hosting 32 Silicon photomultipliers (see Fig. 6) thanks to a custom made connector.

Figure 6.

Figure 6

A half plane of 32 scintillator bars and 32 wavelength shifting fibres placed in a connector. The connector is optically coupled to 32 Silicon photomultipliers, mounted on a printed circuit board, not shown in the picture. Two half planes mounted side by side form a detection plane.

A full sized module consists of a pair of superimposed planes (see Fig. 5) orthogonally orientated, that provide the x and y coordinates of the muon impact point with a spatial resolution of about 2 mm. Each plane is equipped with two Front-End Electronics (FEE) boards based on the ASIC chip EASIROC21. The passage of a penetrating charged particle through the detector provides a fast digital signal each time a muon crosses a detection plane. A time coincidence of the signals from the six planes triggers the data acquisition. The analogue information related to the amount of energy released by muons in each bar is digitised by Analog to Digital Converters (ADC), acquired by Data Acquisition (DAQ) boards and stored for offline reconstruction of the muon tracks. The maximum possible acquisition rate of the detector was about 270 Hz.

The setup installed at Mt. Echia consisted of a vertical sequence of three modules, mounted horizontally on a support and evenly spaced in the vertical direction (z-axis) as shown in Fig. 5. In the setup used for the measurement reported here, the distance between the bottom and the top module was about 50 cm. In this configuration the muon track angular resolution was 4 mrad in each projection with a maximum observable field of view from the Zenith of about 63°. During the whole data taking, a control system maintained the SiPM temperature at about 18 °C with a stability of about 0.01 °C, using an hydraulic circuit connected to a chiller.

Data taking

Approximatively 14 × 106 events were acquired during two different periods of 26 days in total under Mt. Echia. Data taking was performed in runs of about 1 hour, storing all the ADC outputs whenever a trigger was generated. Pedestal events were also acquired to calculate offsets and noise values.

For each run the trigger rate, the accidental trigger rate, the dark rates of the SiPMs and the offsets (pedestals) of the ADC outputs were monitored, as well as environment and instrument parameters such as environmental temperature, relative humidity and dew point temperature, chiller temperature, electrical power consumption, currents and voltages supplied to the SiPMs. All these parameters were found to be stable, as shown in Figs 7 and 8.

Figure 7.

Figure 7

Stability of the main parameters that monitor the status of the detector during the Mt. Echia data tacking. Top: Environmental temperature, dew point temperature, chiller temperature and power, relative humidity. Bottom: Trigger rate, accidental rates, environmental temperature. The drawing was obtained using the software root.

Figure 8.

Figure 8

Stability of the main parameters acquired during pedestal runs, for one random channel, during the Mt. Echia data tacking: mean and RMS value of the ADC peak (blue triangles and red squares), the ADC mean value corresponding the single photoelectron response (green triangles). The drawing was obtained using the software root.

Thanks to the excellent intrinsic resolution of the SiPMs, after pedestal subtraction from the ADC spectra the signals corresponding to a single photoelectron (SPE responses) were determined. The SPE responses allow to quantify the average number of photoelectrons produced by a muon in each scintillator bar and to monitor in time the gain stability of the system. The SPE responses were found to be stable during all the data taking periods. The trigger rate was constantly at around 8.1 Hz.

A free sky calibration sample of about 12 × 106 events was acquired in a surface laboratory. In this run, a 25 mm thick iron layer and a 10 mm thick iron lead layer were inserted between the second and the third detector modules from the top. These layers introduced a cut of about 100 MeV on the energy of muons crossing the detector. The trigger rate during the calibration run was 77 Hz.

Muon track reconstruction

Muon tracks are reconstructed event by event independently in the x-z and y-z projections, where x and y represent the coordinates in the horizontal plane and z is the vertical coordinate.

The normalised energy deposited in a scintillator bar is defined as the pedestal subtracted ADC value divided by the SPE. Clusters are formed by considering one or more neighbouring bars with a significant deposit. The normalized energy of a cluster is the sum of the energies of the bars forming the cluster while the x and y coordinates of the cluster are the energy weighted averages of the bars coordinates.

In each projection a successful fit of clusters belonging to the three planes defines a candidate track. The track candidate with the highest value of the minimum cluster energy is defined as the best candidate track. The three-dimensional best candidate track associates the best candidate tracks in the two projections.

Quality cuts were further introduced to improve the purity of the sample. The χ 2/ndf of the fit was required to be less than 5 and the minimum energy of the clusters associated to the track was required to be greater than 4. In addition, we selected events containing only single muon tracks by requiring the absence of other clusters with a normalised energy greater than 4, and we restricted to 2 the maximum number of bars in a given cluster. This sample of golden tracks has a standard deviation of ∼2 mm in the track fit residual distribution.

Events with a golden tracks in both views constitute a 3D muon track, with elevation angle α and horizontal angle ϕ defined as in Fig. 9. Their values are plotted event-by-event in a bi-dimensional histogram, typically with a 3° × 3° binning.

Figure 9.

Figure 9

Definition of the elevation angle α and the horizontal angle ϕ.

Muon transmission

Muon transmission is defined as the ratio between the muon flux reaching the detector divided by the flux impinging on the surface before crossing the thickness of rock under investigation. The presence of a cavity is thus identified by an excess in the measured transmission relative to the expected transmission in its absence.

The number of muons Nu(ρ,α,φ) which in the absence of internal structure (such as cavities) are expected to be recorded underground in any given angular bin around (α,φ) in a data taking time ΔTu can be written as

Nu(ρ,α,φ)=ΔTuSeff(α,φ)EminΦ(α,φ,E)dE 1

where Seff(α,φ) is the so-called effective area of the detector and Φ(α,φ,E) is the differential muon flux as a function of the muon energy E. In particular, the differential muon flux was measured by the ADAMO experiment22 in the zenith angle range 0°–80° and energies in the range 100 MeV–130 GeV. Some of the differential flux curves are shown in Fig. 10.

Figure 10.

Figure 10

Differential muon flux distribution as a function of the muon energy, for different zenith angles, as given in ref. 22. The drawing was obtained using the software root.

The lower limit Emin(ρ,α,φ) of the integral in eq. 1 is the minimum energy that muons must have in order to cross the rock and reach the detector. It depends of average rock density ρ and of the rock thickness, the latter being fixed by the DTM for any given (α, ϕ)23. E min is evaluated from models that parametrise the muon energy loss in matter24. The detector was placed inside a chamber of approximatively cubic shape with sides approximately 3 m long. In order to avoid a systematic overestimation of the rock thickness this empty volume has been taken in account.

The colour scale in the two-dimensional (α, ϕ) histogram shown in Fig. 11 shows the rock thickness surrounding the detector. The minimum energy Emin(ρ,α,φ) in the absence of internal structure that appears in eq. 1 is shown using an appropriate colour scale in the two-dimensional (α, ϕ) histogram shown in Fig. 12, for an uniform average rock density ρ = 1.4 g/cm3.

Figure 11.

Figure 11

Rock thickness d(α, ϕ) crossed by muons reaching the detector under the hypothesis that no cavities are present, evaluated using the Digital Terrain Model. The drawing was obtained using the software root.

Figure 12.

Figure 12

Minimum energy Emin(ρ,α,φ) required for a muon to cross the rock overburden, whose thickness is shown in Fig. 11, evaluated for an uniform average rock density ρ = 1.4 g/cm3. The drawing was obtained using the software root.

The effective detector area does not depend significantly on the muon energy and can be written as follows:

Seff(α,φ)=SA(α,φ)εtrig(α,φ)εDAQ(νtrig)εan(α,φ) 2

where S is the sensitive area of the detector, A(α,φ) is its geometrical acceptance, εtrig(α,φ) is the trigger efficiency, εDAQ(νtrig) is the data acquisition efficiency (that depends of the trigger rate νtrig) and εan(α,φ) is the analysis efficiency.

Similarly, the number of free-sky muons expected in a time interval ΔTfs can be written as:

Nfs(α,φ)=ΔTfsSefffs(α,φ)E0Φ(α,φ,E)dE 3

where E 0 is the minimum energy required to detect muons in the laboratory, estimated at about 100 MeV and supposedly independent of (α, ϕ) in the angular range under study.

The expected ratio between the underground and the free sky samples can be written as

Nu(ρ,α,φ)Nfs(α,φ)=ΔTuSeffu(α,φ)ΔTfsSefffs(α,φ)EminΦ(α,φ,E)dEE0Φ(α,φ,E)dE 4

With good approximation it can be assumed that the geometrical acceptance, the trigger efficiency, and the analysis efficiency are the same in the two data samples and cancel out in the ratio obtaining:

Nu(ρ,α,φ)Nfs(α,φ)=CEminΦ(α,φ,E)dEE0Φ(α,φ,E)dE 5

where C is the calculable constant

C=ΔTuΔTfsεDAQ(νfs)εDAQ(νu) 6

The quantity

T(ρ,α,φ)=EminΦ(α,φ,E)dEE0Φ(α,φ,E)dE 7

represents the expected transmission (see Fig. 13).

Figure 13.

Figure 13

The expected transmission. The drawing was obtained using the software root.

Its value is obtained using an integration limit Emin(ρ,α,φ) evaluated as specified above, under the hypothesis that no cavities are present.

From eq. 5, the measured transmission is calculated as

Tm(α,φ)=1CNu(α,φ)Nfs(α,φ) 8

In Fig. 14 the rate of free-sky muons measured in laboratory, the rate of underground muons measured under Mt. Echia and the measured transmission are shown as function of the elevation and horizontal angles.

Figure 14.

Figure 14

(A) Rate of free-sky muons measured in laboratory. (B) Rate of underground muons measured under Mt Echia. (C) Measured transmission. The drawing was obtained using the software root.

The relative transmission R(ρ, α, ϕ) is defined as the ratio between the measured and the expected transmission:

R(ρ,α,φ)=Tm(α,φ)T(ρ,α,φ) 9

The relative transmission equals unity in case no internal structure is present and the correct rock density ρ is inserted.

The density of a grain of yellow tuff is in the range of 2.4 ÷ 2.5 g/cm3 and the porosity is in the range of 50% ÷ 60%. Typical values of the density of dry yellow tuff in the Naples area are in the range 1.0 ÷ 1.2 g/cm3, but the actual density depends of the water contents25, 26. The path length of muons in the rock is evaluated from the DTM, so that the presence of buildings is accounted for by an “effective density” higher the real rock density. As a first step in the evaluation of the expected transmission, hence of the relative transmission, we take an effective density ρ = 1.4 g/cm3. Figure 15 gives the map of the relative transmission R(ρ, α, ϕ), The smoothing algorithm contour4 of the root analysis software tool is applied27.

Figure 15.

Figure 15

The relative transmission R(ρ,α,φ) evaluated with ρ = 1.4 g/cm3. Regions with values higher than 2.5 have been saturated at this value. Also shown are five regions, where minimal relative transmission values have been selected to evaluate the best estimation of the density. The drawing was obtained using the software root.

Measurement of the rock density

A measurement of the effective density can be performed using angular regions where minimal relative transmission values are present. One may assume that in these regions no cavities have been encountered by muons and the value R = 1 is expected.

Five regions (R 1R 5) were defined (see Fig. 15) and the relative transmission value for different density values was evaluated. Figure 16 gives the relative transmissions in the five regions and in their total, as functions of ρ, using values R < 0.85.

Figure 16.

Figure 16

Relative transmissions in the five regions R 1R 5 (separately and in total) as functions of ρ. The drawing was obtained using the software root.

The density was evaluated by interpolating the line in R = 1 giving a density ρ m = 1.71 g/cm3.

Repeating the procedure using value of R < 0.75 gives a difference less than 3%.

The standard deviation of the average value obtained from separate fits to the five regions is σ ρ = 0.013 g/cm3. Another contribution to the error in the density measurement comes from the uncertainties in the rock thickness from the DTM (1 m in x and y, 10 cm in z) and from the error in the detector position. The entire density measurement procedure was thus repeated changing rock thickness up to 5 m, in steps of 1 m. The trend is approximatively linear and the error is 0.04 g/cm3 for 1 meter uncertainty. Adding in quadrature the two contributions, one obtains an error of 0.042 g/cm3 (2.5%) in the density measurement. The statistical contribution was evaluated and is negligible.

In principle, through a nonlinear, effect a deviation of ρ from reality may fake a non uniformity that could erroneously be attributed to a fake internal structure. Actually, with a good approximation, Emin(ρ,α,φ) depends linearly of the rock density. However, the nonlinearity of muon spectrum (Fig. 10) reflects in a nonlinear dependence of the expected transmission of Emin(ρ,α,φ), hence also of ρ, resulting in an apparent not uniformity in the transmission. Quantitatively, a deviation within the above mentioned (a priori) density range of yellow tuff in the Naples area (±20%) was found to induce a fake disuniformity smaller than ∼4%. Such a fake disuniformity would limit the sensitivity to the detection of cavities e.g. to a 1.5 m size over 50 m rock thickness. This sensitivity limit is further reduced when considering the above uncertainty on the measured density.

Observed structures

Figure 17 shows the known cavities in the neighbourhood of the detector. The total rock thickness in the vertical direction above the detector amounts to about 40 m. Figure 17 shows the structures within the geometrical acceptance of the detector, a cone of ∼60° semi-aperture from Zenith.

Figure 17.

Figure 17

Left: top view of the known structures in the neighbourhood of the detector. The orange box shows the detector position, below the room indicated by the dashed line. Right: 3D view. The cone, with ∼120° of aperture, represents the angular acceptance of the detector. The drawings were obtained using the software Autodesk AutoCAD 2015.

Muographic evidence of such structures emerges already after some hours of data taking: Fig. 18 shows how the angular map of the relative transmission takes shape during the first 5 hours. The top part of Fig. 19 shows the map (using angular coordinates) that was obtained in 26 days of data taking. Both maps are evaluated with the measured density ρ m = 1.71 g/cm3.

Figure 18.

Figure 18

Time sequence of muographies obtained in 5 hours of data taking. The drawing was obtained using the software root.

Figure 19.

Figure 19

Top: Relative transmission R(ρ,θ,φ) evaluated with the best estimate of the tuff density ρ = 1.71 g/cm3; the black dots lie on the contour of one of the structures which are observed. Bottom: Projection of the black dots in the top figure at z = 25 m, corresponding to the ceiling of a known structure. The drawings were obtained using the software root and Autodesk AutoCAD 2015.

We focus on one of the structures which are observed in the top part of Fig. 19. This structure is identified by the black dots lying on its contour, as defined by the level R = 1.71 of the relative transmission. We seek a correspondence with a sequence of known cavities located above the detector, all of them having a height of about 4.5 m and with the ceiling at 25 m altitude a.s.l. The 3D image given in the bottom part of Fig. 19 thus includes (red dots) the projections at z = 25 m of the black dots lying on the contour of the above structure in the muography. The correspondence of the muographic image to a real structure is demonstrated once the slanted view of the cavities from the detector location is taken into account.

Most of the other structures that are muographically visible point to known structures. A hint of the presence of a hidden cavity is given by the structure indicated by a dashed line in Fig. 20. This structure could be a partially filled cavity which geologists, currently investigating the system of cavities in the neighbourhood of the Galleria Borbonica, suspect could be present in that direction.

Figure 20.

Figure 20

A structure evidenced by the muographic image and with contour shown by a dashed line, without any correspondence among the known structures. The drawing was obtained using the software root.

Conclusions

A new generation muon detector exploiting current state of the art technologies was installed in a cavity in Mt. Echia in Naples under about 40 m of yellow tuff overburden, and took data in a 26 days pilot run. The average rock density was measured, improving the imaging sensitivity. The muography technique was validated by the identification of known internal structures, already evident after a few hours of data taking. Hints of the existence of so far unknown cavities have been obtained. Further measurements will be performed from different detector locations, in order to stereoscopically reconstruct in space the observed cavities and possibly confirm the hints for structures which have not yet been discovered by other conventional means.

The amount of matter overburden at Mt. Echia (about 40 m) is of general interest for a wide range of applications including archaeology, geological surveys and civil engineering. By exploiting present electronic technologies, compact muon detectors can be built that are capable of providing useful data in a matter of weeks and to analyse them quasi online by standard means from remote locations. The successful observations reported here may thus have a broader impact on the long awaited establishment of muography as a standard technique.

Acknowledgements

The development of the muography detector was funded by INFN in the frame of the MU-RAY and MURAY2 projects. We also acknowledge the support given by the Regione Campania, by the Provincia di Napoli, and by the Istituto Fondazione Banco di Napoli. The measurement at Mt Echia was supported by the STRESS S.c.a r.l. company in the frame of the project METROPOLIS-PON 03PE_00093_4 (DD MIUR prot. no. 0000791 of the 06/03/2014) funded by the Italian Ministry for Education, University and Research (PON R&C 2007-2013, DD 713/Ric of the 29/10/2010 Tit III). We warmly acknowledge the contributions to the development of the detector by G. Iacobucci (now at the University of Geneva), G. Castellini (CNR) and F. Garufi (University of Naples Federico II), as well as A. Bross (Fermilab), A. Pla Dalmau (Fermilab/NICADD), L. Raux (OMEGA - Ecole Polytechnique - CNT) and S. Callier (OMEGA - Ecole Polytechnique - CNRS/IN2P3). We also acknowledge the support given by the INFN technical staff, in particular by V. Masone and R. Ciaranfi for electronics design, and by P. Mastroserio, P. Lo Re and R. Esposito for the Internet connection under Mt. Echia. We finally express our gratitude to N. Mori (INFN), D. Sala (TECNO-IN S.P.A.), M. Esposito and V. James (STRESS S.c.a r.l.) and to the members to the Association Borbonica Sotterranea.

Author Contributions

G. Saracino led the research team and prepared the original manuscript. P. Strolin and R. D’Alessandro had important roles in the research and in the editing of the final manuscript. L. Cimmino supervised the detector activity during the data acquisition. P. Noli supervised the data analysis. All authors reviewed the manuscript and contributed to the research. In particular: F. Ambrosino, L. Cimmino, P. Noli, G. Saracino, and P. Strolin are the main contributors to the data analysis. F. Ambrosino and P. Noli produced the track reconstruction code and M. Carlo simulations. L. Amato, and G. Minin contributed to the definition of the site investigated. L. Bonechi contributed to the estimate of the muon flux on the surface. L. Cimmino, L. Scognamiglio took care of the data quality and detector status during the data acquisition. L. Cimmino, L. Consiglio, P. Noli, De Luzio, L. Scognamiglio, A. Varriale took care of detector installation under Mt. Echia. L. Amato, G. Antonucci prepared the DTM data used in Figs 1 and 2. P. Noli prepared Figs 1, 2, 10, 11, 12, 13, 14, 15, 16, 18 and 20. L. Cimmino prepared Fig. 6. L. Scognamiglio prepared Figs 7 and 8. L. Cimmino, P. Noli, E. De Luzio and G. Minin prepared Figs 17 and 19.

Competing Interests

The authors declare that they have no competing interests.

Footnotes

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.George, E. P. Cosmic rays measure of overburden of tunnel. Commonwealth Eng. 455–7 (1955).
  • 2.Alvarez LW, et al. Search for hidden chambers in the pyramids. Science. 1970;167:832–839. doi: 10.1126/science.167.3919.832. [DOI] [PubMed] [Google Scholar]
  • 3.Okubo S, Tanaka HKM. Imaging the density profile of a volcano interior with cosmic-ray muon radiography combined with classical gravimetry. Meas. Sci. and Technol. 2012;23:042001. doi: 10.1088/0957-0233/23/4/042001. [DOI] [Google Scholar]
  • 4.Tanaka, H. K. M., Kusagaya, T. & Shinohara, H. Radiographic visualization of magma dynamics in an erupting volcano. Nature Communications5 (2014). [DOI] [PMC free article] [PubMed]
  • 5.Saracino, G. & Carlôganu, C. Looking at volcanoes with cosmic-ray muons. Physics Today65, number 12, 60–61 (2012).
  • 6.Ambrosino F, et al. Joint measurement of the atmospheric muon flux through the Puy de Dôme volcano with plastic scintillators and resistive plate chambers detectors. Journal of Geophysical Research B: Solid Earth. 2015;20(Issue 11):7290–7307. [Google Scholar]
  • 7.Lesparre N, et al. Density muon radiography of La Soufriěre of Guadeloupe volcano: comparison with geological, electrical resistivity and gravity data. Geophys. J. Int. 2012;190:1008–1019. doi: 10.1111/j.1365-246X.2012.05546.x. [DOI] [Google Scholar]
  • 8.Carlôganu C, et al. Towards a muon radiography of the Puy de Dôme. Geosci. Instrum. Method Data Syst. 2013;2:55–60. doi: 10.5194/gi-2-55-2013. [DOI] [Google Scholar]
  • 9.Marteau, J. et al. Muon tomography applied to active volcanoes. PoS PhotoDet2015004 (2016).
  • 10.Basset M, et al. MGR: an innovative, low cost and compact cosmic-ray detector. Nuclear Instruments and Methods A. 2006;567:298–301. doi: 10.1016/j.nima.2006.05.099. [DOI] [Google Scholar]
  • 11.Menichelli M, et al. A scintillating fibres tracker detector for archaeological applications. Nuclear Instruments and Methods A. 2007;572:262–265. doi: 10.1016/j.nima.2006.10.317. [DOI] [Google Scholar]
  • 12.Malmqvist L, Jönsson G, Kristiansson K, Jacobsson L. Theoretical studies of in-situ rock density determinations using underground cosmic-ray muon intensity measurements with application in mining geophysics. Geophysics 44. 1979;9:1549–1569. doi: 10.1190/1.1441026. [DOI] [Google Scholar]
  • 13.Levy RH, Mockett P, Tosaya C. Third Technical Symposium On Tunnel Detection Proceedings. Colorado: Golden; 1988. Sensitivity analyses of muon tomography for tunnel detection; pp. 284–298. [Google Scholar]
  • 14.Celmins, A. Feasibility of cosmic-muon intensity measurement for tunnel detection. Technical report BRL-TR-3110 (1990).
  • 15.Caffau E, Coren F, Giannini G. Underground cosmic-ray measurement for morphological reconstruction of the “Grotta Gigante” natural cave. Nuclear Instruments and Methods A. 1997;385:480–488. doi: 10.1016/S0168-9002(96)01041-8. [DOI] [Google Scholar]
  • 16.Ambrosino F, et al. Assessing the feasibility of interrogating nuclear waste storage silos using cosmic-ray muons. Journal of Instrumentation. 2015;10(Issue 6):T06005–T06005. doi: 10.1088/1748-0221/10/06/T06005. [DOI] [Google Scholar]
  • 17.Anastasio A, et al. The MU-RAY experiment. An application of SiPM technology to the understanding of volcanic phenomena. Nuclear Instruments and Methods A. 2013;718:134–137. doi: 10.1016/j.nima.2012.08.065. [DOI] [Google Scholar]
  • 18.Anastasio A, et al. The MU-RAY detector for muon radiography of volcanoes. Nuclear Instruments and Methods A. 2013;732:423–426. doi: 10.1016/j.nima.2013.05.159. [DOI] [Google Scholar]
  • 19.Ambrosino, F. et al. The MU-RAY project: detector technology and first data from Mt. Vesuvius. Journal of Instrumentation9 (2014).
  • 20.Pla-Dalmau, A., Bross, A. D. & Mellot, K. L. Extruded plastic scintillation detectors. FERMILAB-Conf-99/095.
  • 21.Callier S, de La Taille C, Martin-Chassard G, Raux L. EASIROC, an easy & versatile readout device for SiPM. Physics Procedia. 2012;37:1569–1576. doi: 10.1016/j.phpro.2012.02.486. [DOI] [Google Scholar]
  • 22.Bonechi, L. et al. Development of the ADAMO detector: test with cosmic rays at different zenith angles. 29th Int. Cosmic Ray Conference, Pune9, 283–286 (2005).
  • 23.D’Alessandro R, Mori N, Viliani L. A projective reconstruction method of underground or hidden structures using atmospheric muon absorption data. JINST. 2015;10:P02003–P02003. doi: 10.1088/1748-0221/10/02/P02003. [DOI] [Google Scholar]
  • 24.Groom DE, Mokhov NV, Striganov SI. Muon stopping power and range tables 10 MeV–100 TeV. Atomic Data and Nuclear Data Tables. 2002;76:183–356. [Google Scholar]
  • 25.Pellegrino, A. Proprietà fisico-meccaniche dei terreni vulcanici del Napoletano. Associazione Geotecnica Italiana (AGI). Atti del VII Convegno di Geotecnica. Cagliari 67 febbraio 113–145 (1967).
  • 26.Papa, L. I tufi vulcanici nel costruito storico: vulnerabilità e possibili trattamenti per la conservazione e il restauro. PhD Thesis, Università degli Studi di Sassari (2011).
  • 27.Brun R, Rademakers F. ROOT - An object oriented data analysis framework. Nucl. Inst. and Meth. in Phys. Res. A. 1997;7389:81–86. doi: 10.1016/S0168-9002(97)00048-X. [DOI] [Google Scholar]

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES