Abstract
We report a three dimensional (3D) quantitative visualization of a mammalian mitochondrion by coherent x-ray diffractive imaging (CXDI) using synchrotron radiation. The internal structures of a mitochondrion from a mouse embryonic fibroblast cell line (NIH3T3) were visualized by tomographic imaging at approximately 60 nm resolution without the need for sectioning or staining. The overall structure consisted of a high electron density region, composed of the outer and inner membranes and the cristae cluster, which enclosed the lower density mitochondrial matrix. The average mass density of the mitochondrion was about 1.36 g/cm3. Sectioned images of the cristae reveal that they have neither a baffle nor septa shape but were instead irregular. In addition, a high resolution, about 14 nm, 2D projection image was captured of a similar mitochondrion with the aid of strongly scattering Au reference objects. Obtaining 3D images at this improved resolution will allow CXDI to be an effective and nondestructive method for investigating the innate structure of mitochondria and other important life supporting organelles.
Introduction
Over the last few decades, there has been enormous effort to visualize the internal structures of cellular organelles utilizing a variety of microscopy techniques such as optical, fluorescence, and electron microscopies1–10. Most methods, however, have limitations either in resolution or are disruptive to the sample under investigation. The resolution of conventional optical microscopies is fundamentally limited to several hundred nanometers due to long wavelengths used, following Abbe’s principle. This is not sufficient to observe most sub-cellular structures. Fluorescence microscopies can overcome the diffraction limit through the use of extensive labeling and computational techniques, however labeling can interfere with quantitative visualization and observed structures lack an overall cellular context. Much higher spatial resolution is available in electron microscopies but thick specimens have to be sectioned which disrupts their internal structure, and in addition most of them need to be stained with heavy metals, which complicates image interpretation11–13. Moreover, all these methods suffer from the aberration issues caused by various types of lenses involved in microscopes.
Coherent x-ray diffractive imaging (CXDI), which has the ability to visualize non crystalline specimens nondestructively at about 10~20 nm resolution, offers an alternative to conventional microscopy methods14–19. In CXDI, two-dimensional diffraction patterns are directly recorded from x-rays that penetrate through a specimen and diffract. These patterns are phased directly in iterative phase retrieval algorithms to produce corresponding projection images. CXDI is a lens-free technique, since images are reconstructed computationally from the measured diffraction signal without employing any image forming lenses. Two-dimensional (2D) projection images at various angles can also be assembled to reconstruct a three-dimensional (3D) image using the tomography principle20, 21. 3D imaging of human chromosome22, mammalian nucleus23 and several unicellular organelles17, 24, 25 have been successfully demonstrated using CXDI.
In this work, we demonstrate the feasibility of CXDI for imaging the internal structure of a mammalian mitochondrion three dimensionally. Mitochondrion is an essential eukaryotic organelle involved in diverse cellular processes including; energy generation, senescence, cell growth, reproduction, genetics and maternal inheritance26–29. Given their central role in such a diverse array of cellular function the structure of mitochondria has been the subject of intensive study26–29. The functions of mitochondria are known to be closely related to their intricate internal structure, although this depends on the species, organs, and cells in which they reside12, 30. Cristae, the distinct invaginations of inner membrane of mitochondria, for example, the site of the electron transport chain and ATP synthase that generate ATP, which is the dominant source of intracellular energy26–29. The complicated internal structure of the cristae enlarges surface area and increases the enzymatic reaction sites for ATP synthesis.
The internal ultra-structure of mitochondria is typically classified into three shapes: normal (tubule and branch), non-tubular, and swollen shape31. The structures have only been observed, however, from samples that have been sectioned and stained, which hinders precise measurement and introduces artifacts making interpretation of their density maps difficult. In this work, we illustrate the feasibility of visualizing unstained and unsectioned mitochondria by applying CXDI to a mitochondrion of NIH3T3 (primary mouse embryonic fibroblasts cell line) which is a standard mammalian fibroblast cell line. A 3D image reconstructed by tomographically assembling 2D projection images at various angles was used to reconstruct a quantitative 3D density map. Furthermore, a high resolution 2D projection image was obtained using strongly scattering Au reference objects32, 33 that amplify the diffraction signal.
Results and Discussion
2D projection imaging of a mammalian mitochondrion
Figure 1(a,b) show the diffraction amplitude and the reconstructed projection image of a mitochondrion obtained at zero degree projection angle. The coherent x-ray diffraction measurements were performed at BL29XU at SPring-8, a third generation synchrotron source in Japan. The energy of the x-ray beam was fixed at 5 keV and the specimen was confined within the coherent volume of the incident x-ray beam, ensuring that the recorded far-field diffraction pattern was the exact square of the Fourier transform of the electron density integrated along the incident x-ray beam direction (projected density). The shape of the projection image in Fig. 1(b) matches well with the morphology shown in the scanning electron microscopy (SEM) image in Fig. 1(c). However, the size of mitochondrion in the SEM image is slightly smaller than retrieved image shown in Fig. 1(b). We suspect that some shrinkage occurred during the SEM imaging process due to the high vacuum, 4.4 × 10−4 Pa, and electron beam intensity, with acceleration voltage of 10 kV, used during this measurement rather than the x-ray exposure. We confirmed that there was no significant change due to the x-ray irradiation by measuring the zero degree diffraction profile again after a long exposure (total of 470 min.) and reconstructing the projected image (Supplementary Fig. S1). We also observed the shrinkage of the image of a mitochondrion by an SEM measurement.
The CXDI image shown in Fig. 1(b), retrieved by the guided hybrid-input-output (GHIO) algorithm34, provides traces of the structure including a low-density internal region surrounded by a higher density exterior, however it is difficult to make such interpretations from the two dimensional image since it represents the electron density map integrated along the direction of the incident x-ray beam. This makes quantitative interpretation of the projection image difficult. The surrounding outer region with high electron density is composed of mitochondrial membranes and cristae. Several bulged objects indicated by arrows in Fig. 1(b) are undesired dust particles which were attached to mitochondrion during specimen extraction or deposition on to the Si3N4 substrate. The bulged objects were mostly composed on carbon and oxygen as confirmed in an scanning electron microscopy energy dispersive spectroscopy (SEM-EDS) analysis, and it is likely that they were cell remnants of remained during the sample preparation.
The image pixel size in Fig. 1(b), set by the extent of the diffraction intensity shown in Fig. 1(a), is about 36 nm. The spatial resolution was conservatively estimated to be 55 nm using the phase retrieval transfer function (PRTF)35 shown in Fig. 1(d). Although the value of PRTF was over the typical resolution criterion, 1/e, employed in most CXDI imaging, the decrement stagnated after the half period of 55 nm which is marked with a dotted line in the figure where we set the spatial resolution. Although there is another degressive edge near 150 nm, we have selected the 55 nm since the PRTF is closer to 1/e. In the reconstructed images both in 2D and 3D, we found several features smaller than 100 nm concluded that 55 nm edge was the more reasonable choice.
3D tomographic visualization and analysis on mammalian mitochondrion
For 3D visualization of the mitochondrion, we obtained a set of 26 diffraction profiles measured at incrementing projection angles ranging from −63.43° to 69.44° by rotating the sample around an axis perpendicular to the x-ray beam direction. These angles were selected specifically to follow an equally sloped trajectory necessary for use in the equally sloped tomography (EST) method20, 21. EST minimizes the number of projection images necessary for accurate 3D reconstruction, which reduces data acquisition time and subsequently reduces the radiation dose imparted to the specimen. It took about 11.5 hours to acquire the entire tomography series, which corresponds to about 4.26 × 108 Gy of radiation dose (see methods). Judging from the studies on the radiation damage threshold36, this amount of radiation dose would not cause significant radiation damage to features of interest at the observed resolution.
Shown in Fig. 2 are 9 representative 2D projection images reconstructed from the diffraction patterns measured at the corresponding angles. All 26 diffraction data and reconstructed images are shown in the supplementary information (Supplementary Fig. S2). The images changed consistently as the projection angle was incremented. Regions exhibiting significant density variations over two or three pixels, as marked by arrows in the images, indicate the existence of small structures separating low density hollows. To reconstruct a 3D image from the projection CXDI images using the EST tomographic algorithm20, 21, we aligned all 26 projection images along the rotation axis and matched the center of mass of each projection. Detailed procedures for data measurement and image reconstruction are described in the methods section. Based on the PRTF analysis, we estimate the resolution of the 3D image to be about 60 nm (Supplementary Fig. S3) similar to that of the 2D image (Fig. 1(d)).
A 3D rendering of the reconstructed tomographic image illustrated in Fig. 3(a) shows that the mitochondrion was ellipsoidal in shape and about 1.7 (1.2) μm in length in the major (minor) axis direction. The volume of retrieved mitochondrion, excluding the bulged objects, was 2.83 μm3. The total number of electrons in the mitochondrion was estimated to be 1.24 × 1012 and the mass density deduced from this was 1.36 g/cm3. When we isolate mitochondria from cells, the mass density of each mitochondrion was estimated to be of order 1.15 g/cm3 37, about 84% of the estimation from the tomography analysis. The estimation of the electron density, the volume, the mass density, and the mitochondria isolation procedure are described in the methods section.
The rendering shows that the high electron density outer region encloses a rather low density internal area and defines the mitochondrial shape. We suspect that the high density region consists of the mitochondrial membranes (inner and outer) and cristae stemming from them, although each face of cristae, whose typical thickness is reported to be about 12–40 nm12, is too small to be resolved at the current resolution. The low density inner region supposedly includes semifluid matrix containing mitochondrial DNA molecules, ribosomes as well as various kinds of enzymes involved in mitochondrial function. When we define a density cutoff for the mitochondrial matrix at 53.4% of the maximum density, ρ max of 1443.6 electrons/nm3, the volume occupied by the matrix is 2.15 μm3, about 76.0% of the whole mitochondrial volume. Although the specimen was chemically fixed to prevent morphology distortion, some of solid components might have migrated to the surface of membrane during the drying process.
Cross-sections of the 3D image sliced at 109 nm intervals are illustrated in Fig. 3(b). Each image shows the electron density map on the surface of the corresponding slice averaged over two pixels perpendicular to the surface. These sectioned images show that the cristae are neither in typical baffle shape with wide openings into the matrix nor septa shape, but rather irregular in shape. They stem from the membranes in the outside and connected internally as indicated in one of the slices shown in Fig. 3(c). The thickness of each structure which is considered as an infolding extends to about three pixels, ~100 nm as indicated by an arrow. Although we found several features smaller than 100 nm in the reconstructed images (Supplementary Fig. S4), the current resolution, about 60 nm, was not quite enough to identify the detailed layer structure of the cristae infoldings.
More detailed section images are illustrated in Supplementary Figs S5–S7 which show surface images of the sections cut in every other pixel normal to the image plane in all three directions. The cristae morphology appears differently depending on the direction and position of sections. The infolding structures are more noticeable in the slices sectioned in the y-z plane (Supplementary Fig. S5), but it is difficult to identify them in the slices cut in the x-z, and y-z planes (Supplementary Figs S6 and S7). Some cristae might be grouped together within the mitochondrial membrane to form thick crust regions. It is known that the internal structure of a mitochondrion varies a lot depending on the species, organ or tissue in which they reside12, 30. Moreover, it is possible that several classes of internal structures are present inside a single mitochondrion. The capability of sectioning in an arbitrary direction computationally is a great advantage of the 3D CXDI tomography as compared to TEM which requires physical thin sectioning that damages a specimen, which makes it impossible to view in other sectioning direction.
Resolution enhancement using reference Au particles
Although the 3D reconstruction presented above visualizes the overall internal structure of the mitochondrion, the resolution places limits on detailed, quantitative interpretation of internal features such as the cristae. The limitation in the image resolution was mainly caused by the lack of meaningful diffraction signal at high diffraction angles as in most reported CXDI experiments of biological specimens. To increase the range of diffraction signals, higher incident x-ray flux or longer exposure is necessary which inevitably leads to significant radiation damage. Recent ‘diffraction-before-destruction’ methods based on XFEL sources open a way to obtain an image at a higher resolution38, 39 without concern over radiation damage. Using an ultrashort intense XFEL pulse which lasts only a few tens of femtoseconds, one might expect to obtain a diffraction pattern prior to the disintegration of a specimen. It is, however, impossible to apply typical tomographic methods for 3D imaging since the specimen would be destroyed after a single 2D measurement in one direction. Recent reports including the work by Kim et al.32 suggested another method of enhancing the spatial resolution without increasing x-ray dose using reference objects. They demonstrated that the strongly scattering reference objects enhance the spatial resolution in CXDI imaging significantly. The interference signal between the reference objects and a specimen increases as the square root of the reference signal. In the meanwhile, the Poisson’s noise would also increase in a similar manner, and there is no gain in the signal-to-noise ratio. The enhancement, however, appears when the instrumental noise becomes larger than the Poisson’s shot noise of the sample object. By comparing the signal-to-noise ratio with and without the reference object, they showed that the resolution can be enhanced by using reference objects. In their simulation on a biological object with similar density as a mitochondrion, they demonstrated that Au reference objects of a few 100 nm size enhance the CDI resolution significantly. By introducing Au particles as strongly scattering reference objects near a mitochondrion specimen and increasing incident flux density by focusing x-rays employing Kirkpatrick-Baez (K-B) mirrors, we achieved a high resolution 2D image of a mitochondrion. As shown in the measured diffraction amplitude in Fig. 4(a), the diffraction signal extends across the entire area of the CCD chip. Shown in Fig. 4(b) is the CXDI image of the mitochondrion specimen together with the reference Au particles reconstructed from the data in Fig. 4(a) using a GHIO algorithm. Figure 4(c) shows the PRTF calculated from the phase retrieval iterations. It remains above 0.7 across the entire range of the spatial frequency space indicating that the image resolution is comparable to the single pixel size of 14 nm. This implied that the factor limiting the resolution is not the diffracted signal but the range of the detector. Although there exists some density variations over two to three pixels in Fig. 4(b) and the line profile across the a Au particle is sharp reflecting the improved resolution (Supplementary Fig. S8), the complex internal structures of mitochondrion were not distinguishable because it is a projected 2D image where the densities are integrated along the beam direction. It is difficult to resolve structures with weak density variations in a 2D projected image.
The CXDI image was compared to atomic force microscopy (AFM), fluorescence microscopy, and SEM images shown in Fig. 4(d–f). The AFM image shows the surface profile of the mitochondrion which matches well with the CXDI image. The mitochondrion is thicker than the Au reference objects (Fig. 4(d)), but it has lower density as shown in reconstructed image (Fig. 4(b)). The components of biological materials are mostly composed of light elements and the mitochondrion has large empty space inside. The fluorescence microscopy image shown in Fig. 4(e) identifies the mitochondrion emitting green light although the shape is not clearly distinguishable due to very limited resolution. The mitochondrion was stained with Rhodamine123. (see methods). The mitochondrion was shrunken by electron beam under vacuum as shown in the SEM image (Fig. 4(f)) which was performed after all the other imaging methods.
Conclusion
In this work, a mammalian mitochondrion from a mouse embryonic fibroblasts cell line was visualized in 3D by using CXDI nondestructively without cutting and staining. A 3D density map of the mitochondrion was obtained quantitatively at about 60 nm spatial resolution. The mitochondrion was in an ellipsoidal shape with a low density inner matrix was enclosed by a loosely connected outer crust. The internal morphology is not in line with the typically reported regular shape such as baffle or septa structures, but rather has an irregular arrangement. Structures on the order of 100 nm in size, considered to be cristae, were observed via computational sectioning of the reconstructed volume. They were loosely connected to the outer wall composed of mitochondrial membranes. The capability of sectioning in arbitrary directions was powerful in visualizing the internal structure of the mitochondrion.
The 3D spatial resolution presented here was not quite enough to resolve the detailed structure of cristae reliably. By introducing amplifying reference objects, the spatial resolution of a 2D image was enhanced up to 14 nm. We suggest that 3D CXDI visualization with an improved resolution is feasible by employing the reference objects. We expect that the detailed internal structure will be revealed by 3D CXDI tomography with a high resolution in the near future. High resolution 3D CXDI visualization would answers various questions involved in mitochondrial functions and diseases related to mitochondria.
Methods
Mitochondria isolation
NIH3T3 cells, the mouse embryonic fibroblasts were cultured in petri dishes (10 pi, Corning) and submerged into Dulbecco’s modified Eagle’s medium (DMEM, GIBCO) with 10% fetal bovine serum (FBS, GIBCO) and 1% antibiotics (GIBCO). They were incubated at 36 °C in a humidified incubator with 5% CO2 to proliferate cells for more than 24 hours. When the cells grew and covered more than 70% of a dish, they were immersed in a solution of 0.25% trypsin and 0.02% ethylenediamine tetraacetic acid (EDTA) for three minutes to detach cells from the dish. The solution was neutralized using the same amount of DMEM with 10% FBS to prevent cell damage. The solution was removed by centrifuging at 4 °C, 1,500 rpm for 3 minutes, and the cell pellets detached from the dish were washed by phosphate buffered saline (PBS) to remove remaining trypsin/EDTA.
We followed the protocol of OptiPrep™ (Axis-Shield)40 for solution compositions and procedures to isolate mitochondria. The cells thus prepared were first suspended in a homogenization medium and homogenized using a tight-fitting Dounce homogenizer (Wheaton Type A), then centrifuged at 4 °C at 1,000 rpm for 10 minutes. We extracted supernatant and kept it separately. The remaining cell pellets were resuspended in the homogenization medium and homogenized by loose-fitting Dounce homogenizer (Wheaton Type B) and centrifuged following the same procedure as before, and we extracted supernatant again. All supernatant was put together and centrifuged. The pellets resulted from the above process, which contain mitochondria, were resuspended by the homogenization medium and used for sucrose gradient centrifugation. These mitochondria extracts were loaded on the bottom of tube for ultracentrifuge and 1.175 g/cm3 and 1.079 g/cm3 sucrose solutions were loaded step by step for sucrose gradient centrifugation. A thin layer of the homogenization medium was added on the top for protection. The solution was centrifuged at 50,000 g (g-force), 4 °C for 4 hours in no break mode. This centrifugation separated mitochondria in a thin layer in the middle of medium corresponding to 1.145 g/cm3 of medium density. After extracting this layer we added the same amount of PBS and centrifuged at 4 °C at a speed of 17,000 g for 15 minutes for washing. This process was repeated for three times, and the mitochondria were fixed by 10% formalin at room temperature for 30 minutes. The formalin was removed after centrifugation at 4 °C and 17,000 g for 15 minutes. The remaining mitochondria pellet was cleaned by PBS and deionized water.
Confirmation of mitochondria
To confirm the extracted particles after isolation were indeed mitochondria, we stained cells using Rhodamine 123 (Sigma), a mitochondria specific dye reported by Johnson1, when the cells proliferated under the culture media in petri dishes. After isolating mitochondria as described above, we checked using a fluorescence microscope to make sure that isolated particles were indeed mitochondria (Fig. 4(e)). The mitochondrion used for the resolution enhancement experiment shown in Fig. 4 was stained by this procedure. The mitochondrion used for the 3D CXDI visualization, however, was not stained in order to obtain natural electron density of a mitochondrion exactly.
Data acquisition for 3D tomography of a mitochondrion
Coherent x-ray diffraction measurements for 3D visualization of a mitochondrion were carried out at BL29XU of SPring-8. The coherent portion of the 5 keV (2.48 Å) incident x-ray beam was isolated by a 10 μm pinhole and a pair of slits made of silicon were used to eliminate parasitic scattering from the pinhole. An isolated mitochondrion placed on a 30 nm thick Si3N4 membrane (Silson Ltd.) was illuminated by the x-ray beam and the diffraction pattern was recorded by an x-ray CCD (PI-LCX, liquid nitrogen cooling type, Princeton Instruments) in the transmission geometry. The experiment was performed in vacuum (10−3 Torr) to minimize air scattering background. The mitochondrion used for the 3D x-ray imaging was not dyed.
Diffraction signal was measured at 26 projection angles, 0°, ±7.13°, ±14.04°, ±20.56°, ±26.57°, ±32°, ±36.87°, ±41.19°, ±45°, ±48.81°, ±53.13°, ±58°, ±63.43°, and 69.44° to reconstruct 3D architecture of a mitochondrion using the tomography principle. To minimize the radiation damage, the angles were selected according to the EST method. To record meaningful diffracted signal with minimal acquisition time at each angle, we measured diffraction signal in low and high diffraction angle regions separately. In the low angle measurement, we blocked the main beam using polished Tantalum blades which also blocked several pixels of the zeroth order speckle. During the measurement in the high angle region, a wider area around the central speckles was blocked to increase the exposure time without having any pixel saturated. A single mitochondrion was used for the measurements at all angles. It took about 26.5 minutes on average to acquire one set of diffraction patterns at each angle. The total exposure time was 689.8 minutes.
Diffraction measurement of a mitochondrion with reference objects
The measurements were also performed at BL29XU of SPring-8. Incident beam of 6 keV (2.07 Å) was focused by K-B mirrors to increase beam intensity to 50 times higher than the unfocused beam. Au reference objects were fabricated by coating Au film using electron beam evaporation on a pre-shaped resist on a Si3N4 membrane patterned by electron beam lithography. The final form of the reference objects were obtained by removing the remaining resist together with Au on top. Mitochondria were deposited exactly on the reference objects by a drop of medium containing isolated mitochondria. The existence of an isolated mitochondrion was confirmed by using a green fluorescence microscope after dying with Rhodamine 123 (Fig. 4(e)).
Image reconstruction
To reconstruct a projection image at each angle, the diffraction data obtained in the low and high angle regions were patched by comparing the recorded amplitude in the overlapped area. Diffraction signal blocked by the beam stopper was replaced with the signal at opposite angles using the centrosymmetry. With the patched diffraction amplitude, we ran the GHIO algorithm34 with 16 different initial conditions for 9 generations to retrieve an electron density map in real space. Three best images with the smallest R-factor were averaged to obtain an 2D projection image. These procedures41 were applied to the data obtained at all 26 angles. For 3D image reconstruction, the center of all 2D projection images were aligned by matching the center of mass42 and the tomography principle was applied. We applied the EST algorithm20, 21 on the 26 images to reconstruct a 3D array of mitochondrion electron density.
Electron density calculation
The electron density of the mitochondrion was estimated using the diffracted x-ray intensity in the central pixel of the CCD, where I(0) is the number of diffracted x-ray photons in the central pixel, I 0 is the incident x-ray flux, r e is the electron scattering length, N e is the number of total electrons interacted with x-rays, and dΩ is the solid angle covered by the pixel43. The mitochondrial electron density was estimated to be order of 107 electrons/voxel although it depends on the microscopic position within the specimen. The size of a single voxel, which was determined by the maximum spatial frequency value, was (36 nm)3.
Radiation dose estimation
For the 3D imaging of mitochondrion, extended exposure was necessary as there were as many as 26 projection angles. To insure that the measured sample was not damaged by the x-ray radiation, we estimated the radiation dose on the sample. The incident x-ray flux (F) was 3.6 × 106 photons/μm 2/s and total exposure time was 689.9 minutes. The specimen density (ρ) was 1.322 g/cm3 and the linear absorption coefficient (μ) is 47.192 /cm assuming that the composition of mitochondrion is similar to that of a protein with empirical composition H50C30N9O10S1 25, 44. The total dose was calculated by D = FμEt/ρ where E is incident x-ray energy and t is total exposure time. From this equation, the amount of radiation on the mitochondrion was calculated to be 4.26 × 108 Gy.
Mass density calculation
The mass density of the mitochondrion is calculated by ρ mass = ρ e M w/Vn e N A where ρ e is the average electron density of mitochondrion, n e is the number of electrons per molecule, M w is molecular weight, V is mitochondrial volume calculated from the retrieved mitochondrion, and N A is Avogadro’s number. We assumed that the mitochondrion was composed of H50C30N9O10S1 25, 44, and n e and M w is 389 electrons/molecule and 728 g/mol respectively. The calculated mass density ρ mass is 1.36 g/cm3. Reported values of mitochondrial mass density range from 1.09 to 1.25 g/cm3 depending on their phases, species and grown medium condition45, 46. The difference between the density obtained from the CXDI image and the value obtained during the mitochondria separation was possibly due to some unwanted particles included in the specimen and the reconstruction error.
3D resolution estimation
The 3D resolution was estimated by evaluating the PRTF at a given spatial frequency using where is the reconstructed diffraction amplitude and is the retrieved phase. The sum was over 10 independent reconstructions. The PRTF value was evaluated at all measured s in all projection angles with a fixed magnitude which were averaged to plot it as a function of as shown in Supplementary Fig. S3. PRTF decreases with increasing and saturated at the dotted vertical line which corresponds to a resolution of 60.3 nm. The saturated PRTF value was larger than the widely used criterion of 1/e or 0.5.
Electronic supplementary material
Acknowledgements
We acknowledge Y.S. Jeon’s group for the help in the preparation of mitochondria specimens. This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIP) through SRC (NRF-2015R1A5A1009962) and 2016R1A6B2A02005471, NRF-2015M2A2A4A03044653, and NRF-2015M2A2A6A03044907. Y. Kim acknowledges NRF-2011-Fostering Core Leaders of the Future Basic Science Program (Global Ph.D. Fellowship).
Author Contributions
D.Y.N., Y.H.K., and C.S. conceived the experiment, Y.H.K., C.K., D.N., S.S.K., J.H.P., S.K., M.G.-J., C.S., Y.K., and D.Y.N. conducted the experiment. Y.H.K., C.K., O.K., T.I., and D.Y.N. analyzed the results. Y.H.K., G.T., C.K. prepared specimen. All authors prepared and reviewed the manuscript.
Competing Interests
The authors declare that they have no competing interests.
Footnotes
Electronic supplementary material
Supplementary information accompanies this paper at doi:10.1038/s41598-017-01833-x
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Johnson LV, Walsh ML, Chen LB. Localization of mitochondria in living cells with rhodamine 123. Proc. Natl. Acad. Sci. USA. 1980;77:990–994. doi: 10.1073/pnas.77.2.990. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Gustafsson MGL. Nonlinear structured-illumination microscopy: Wide-field fluorescence imaging with theoretically unlimited resolution. Proc. Natl. Acad. Sci. USA. 2005;102:13081–13086. doi: 10.1073/pnas.0406877102. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Heintzmann R, Jovin TM, Cremer C. Saturated patterned excitation microscopy-a concept for optical resolution improvement. J. Opt. Soc. Am. A. 2002;19:1599–1609. doi: 10.1364/JOSAA.19.001599. [DOI] [PubMed] [Google Scholar]
- 4.Yang S, Ye F, Xing D. Intracellular label-free gold nanorods imaging with photoacoustic microscopy. Opt. Express. 2012;20:10370–10375. doi: 10.1364/OE.20.010370. [DOI] [PubMed] [Google Scholar]
- 5.Andrews JC, et al. Transmission x-ray microscopy for full-field nano-imaging of biomaterials. Microsc. Res. Techniq. 2011;74:671–681. doi: 10.1002/jemt.20907. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Chen J, et al. 3D nanoscale imaging of the yeast, Schizosaccharomyces pombe, by full-field transmission x-ray microscopy at 5.4 keV. Anal. Bioanal. Chem. 2010;397:2117–2121. doi: 10.1007/s00216-010-3617-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Kim GB, et al. X-ray imaging of various biological samples using a phase-contrast hard x-ray microscope. Micros. Res. Techniq. 2008;71:639–643. doi: 10.1002/jemt.20601. [DOI] [PubMed] [Google Scholar]
- 8.Larabell CA, Le Gros MA. X-ray tomography generates 3-D reconstructions of the yeast, Saccharomyces cerevisiae, at 60-nm resolution. Mol. Biol. Cell. 2004;15:957–962. doi: 10.1091/mbc.E03-07-0522. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Palade GE. An electron microscope study of the mitochondrial structure. J. Histochem. Cytochem. 1953;1:188–211. doi: 10.1177/1.4.188. [DOI] [PubMed] [Google Scholar]
- 10.Miyamoto, K. & Yamaguchi, K. Numerical density estimation of mitochondria in thick slice by transmission electron microscopy. Science on Form: Proceedings of the First International Symposium for Science on Form 517–525 (1986).
- 11.Koning RI, et al. Cryo electron tomography of vitrified fibroblasts: Microtubule plus ends in situ. J. Struct. Biol. 2008;161:459–468. doi: 10.1016/j.jsb.2007.08.011. [DOI] [PubMed] [Google Scholar]
- 12.Zick M, Rabl R, Reichert AS. Cristae formation-linking ultrastructure and function of mitochondria. Biochim. Biophys. Acta. 2009;1793:5–19. doi: 10.1016/j.bbamcr.2008.06.013. [DOI] [PubMed] [Google Scholar]
- 13.Perkins G, et al. Electron tomography of neuronal mitochondria: Three-dimensional structure and organization of cristae and membrane contacts. J. Struct. Biol. 1997;119:260–272. doi: 10.1006/jsbi.1997.3885. [DOI] [PubMed] [Google Scholar]
- 14.Miao J, Charalambous P, Kirz J, Sayre D. Extending the methodology of x-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens. Nature. 1999;400:342–344. doi: 10.1038/22498. [DOI] [Google Scholar]
- 15.Kim S, et al. Coherent hard x-ray diffractive imaging of nonisolated objects confined by an aperture. Phys. Rev. B. 2010;81:165437. doi: 10.1103/PhysRevB.81.165437. [DOI] [Google Scholar]
- 16.Nam D, et al. Imaging fully hydrated whole cells by coherent x-ray diffraction microscopy. Phys. Rev. Lett. 2013;110:098103. doi: 10.1103/PhysRevLett.110.098103. [DOI] [PubMed] [Google Scholar]
- 17.Gallagher-Jones M, et al. Macromolecular structures probed by combining single-shot free-electron laser diffraction with synchrotron coherent x-ray imaging. Nat. Commun. 2014;5:3798. doi: 10.1038/ncomms4798. [DOI] [PubMed] [Google Scholar]
- 18.Song C, et al. Quantitative imaging of single, unstained viruses with coherent x rays. Phys. Rev. Lett. 2008;101:158101. doi: 10.1103/PhysRevLett.101.158101. [DOI] [PubMed] [Google Scholar]
- 19.Song C, et al. Nanoscale imaging of buried structures with elemental specificity using resonant x-ray diffraction microscopy. Phys. Rev. Lett. 2008;100:025504. doi: 10.1103/PhysRevLett.100.025504. [DOI] [PubMed] [Google Scholar]
- 20.Miao J, Förster F, Levi O. Equally sloped tomography with oversampling reconstruction. Phys. Rev. B. 2005;72:052103. doi: 10.1103/PhysRevB.72.052103. [DOI] [Google Scholar]
- 21.Lee E, et al. Radiation dose reduction and image enhancement in biological imaging through equally-sloped tomography. J. Struct. Biol. 2008;164:221–227. doi: 10.1016/j.jsb.2008.07.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Nishino Y, et al. Three-dimensional visualization of a human chromosome using coherent x-ray diffraction. Phys. Rev. Lett. 2009;102:018101. doi: 10.1103/PhysRevLett.102.018101. [DOI] [PubMed] [Google Scholar]
- 23.Song C, et al. Analytic 3D imaging of mammalian nucleus at nanoscale using coherent x-rays and optical fluorescence microscopy. Biophys. J. 2014;107:1074–1081. doi: 10.1016/j.bpj.2014.07.028. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Jiang H, et al. Quantitative 3D imaging of whole, unstained cells by using x-ray diffraction microscopy. Proc. Natl. Acad. Sci. USA. 2010;107:11234–11239. doi: 10.1073/pnas.1000156107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Rodriguez JA, et al. Three-dimensional coherent x-ray diffractive imaging of whole frozen-hydrated cells. IUCrJ. 2015;2:575–583. doi: 10.1107/S205225251501235X. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Becker, W. M., Kleinsmith, L. J. & Hardin, J. The World of the Cell, 5th edn., 400–405 (Benjamin Commings, 2003).
- 27.Griffiths, A. J. F. et al. Introduction to Genetic Analysis, 8th edn., 103–106 (McGrow-Hill, 2005).
- 28.Stern, K. R. Introductory Plant Biology, 10th edn., 181–184 (McGrow-Hill, 2006).
- 29.Nelson, D. L. & Cox, M. M. Lehninger Principle of Biochemistry, 4th edn., 690–722 (W. H. Freeman and Company, 2005).
- 30.Sathananthan AH, Trounson AO. Mitochondrial morphology during preimplantational human embryogenesis. Hum. Reprod. 2000;15:148–159. doi: 10.1093/humrep/15.suppl_2.148. [DOI] [PubMed] [Google Scholar]
- 31.Rafelski SM. Mitochondrial network morphology: building an integrative, geometrical view. BMC Biol. 2013;11:71. doi: 10.1186/1741-7007-11-71. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Kim C, et al. Resolution enhancement in coherent x-ray diffraction imaging by overcoming instrumental noise. Opt. Express. 2014;22:29161–29169. doi: 10.1364/OE.22.029161. [DOI] [PubMed] [Google Scholar]
- 33.Noh DY, Kim C, Kim Y, Song C. Enhancing resolution in coherent x-ray diffraction imaging. J. Phys.-Condens. Mat. 2016;28:493001. doi: 10.1088/0953-8984/28/49/493001. [DOI] [PubMed] [Google Scholar]
- 34.Chen C-C, Miao J, Wang CW, Lee TK. Application of optimization technique to noncrystalline x-ray diffraction microscopy: guided hybrid input-output method. Phys. Rev. B. 2007;76:064113. doi: 10.1103/PhysRevB.76.064113. [DOI] [Google Scholar]
- 35.Chapman HN, et al. High-resolution ab initio three-dimensional x-ray diffraction microscopy. J. Opt. Soc. Am. A. 2006;23:1179–1200. doi: 10.1364/JOSAA.23.001179. [DOI] [PubMed] [Google Scholar]
- 36.Howells MR, et al. An assessment of the resolution limitation due to radiation-damage in x-ray diffraction microscopy. J. Electron Spectrosc. 2009;170:4–12. doi: 10.1016/j.elspec.2008.10.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Axis-Shield. Application sheet S13, 7th edn. - Purification of mammalian peroxisomes in a self-generated gradienthttp://www.axis-shield-density-gradient-media.com/S13.pdf (accessed: 11th nov. 2016).
- 38.Neutze R, et al. Potential for biomolecular imaging with femtosecond x-ray pulses. Nature. 2000;406:752–757. doi: 10.1038/35021099. [DOI] [PubMed] [Google Scholar]
- 39.Barty A, et al. Self-terminating diffraction gates femtosecond x-ray nanocrystallography measurements. Nat. Photonics. 2012;6:35–40. doi: 10.1038/nphoton.2011.297. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Axis-Shield. Application sheet S14, 7th edn. - Purification of mammalian mitochondria in a discontinuous gradienthttp://www.axis-shield-density-gradient-media.com/S14.pdf (accessed: 11th nov. 2016).
- 41.Xu R, et al. Coherent diffraction microscopy at SPring-8: instrumentation, data acquisition and data analysis. J. Synchrotron Radiat. 2011;18:293–298. doi: 10.1107/S0909049510051733. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Scott MC, et al. Electron tomography at 2.4-ångström resolution. Nature. 2012;483:444–447. doi: 10.1038/nature10934. [DOI] [PubMed] [Google Scholar]
- 43.Miao J, et al. Direct determination of the absolute electron density of nanostructured and disordered materials at sub-10-nm resolution. Phys. Rev. B. 2003;68:012201. doi: 10.1103/PhysRevB.68.012201. [DOI] [Google Scholar]
- 44.Giewekemeyer K, et al. Quantitative biological imaging by ptychographic x-ray diffraction microscopy. Proc. Natl. Acad. Sci. USA. 2010;107:529–534. doi: 10.1073/pnas.0905846107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Tzagoloff, A. Membrane Biogenesis: Mitochondria, Chloroplasts, and Bacteria, 1st edn., 184 (Plenum Press, 1975).
- 46.Munn, E. A. The structure of mitochondria, 117 (Academic Press, 1974).
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.