Aortic Shear Stress in Bicuspid Aortic Valve Patients with Stenosis and Insufficiency

Yan Shan a, Jun Li b, Yongshi Wang a,b, Boting Wu e, Alex J Barker c, Michael Markl c,d, Chunsheng Wang b, Xiaolin Wang a, Xianhong Shu a,b
PMCID: PMC5438758  NIHMSID: NIHMS857445  PMID: 28268004

Abstract

Objectives

Bicuspid aortic valve (BAV), characterized by valve malformation and risk for aortopathy, displays profound alteration in systolic aortic outflow and wall shear stress (WSS) distribution. The present study performed 4-dimenstional flow MRI in BAV patients with right-left (R-L) cusp fusion, focusing on the impact of valve function upon hemodynamic status within ascending aorta.

Methods

Four-dimensional flow MRI was performed in 50 R-L BAV subjects and 15 age- and aortic size-matched controls with tricuspid aortic valve. BAV patients were categorized into 3 groups according to their aortic valve function as follows: BAV with no more than mild aortic valve dysfunction (BAV-CTL, n=20), BAV with severe aortic insufficiency (BAV-AI, n=15), and BAV with severe aortic stenosis (BAV-AS, n=15).

Results

All R-L BAV patients exhibited peak WSS at the right-anterior position of the ascending aorta (BAV vs. TAV at right-anterior position: 0.91±0.23 N/m2 vs. 0.43±0.12 N/m2, p<0.001) with no distinct alteration between BAV-AI and BAV-AS. The predominance of dilatation involving the tubular ascending aorta (82%, type 2 aortopathy) persisted, with or without valve dysfunction. Compared to BAV-CTL subjects, the BAV-AI group displayed universally elevated WSS (0.75±0.12 N/m2 vs. 0.57±0.09 N/m2, p<0.01) in the ascending aorta, which was associated with elevated cardiac stroke volume (p<0.05). The BAV-AS group showed elevated flow eccentricity in the form of significantly increased standard deviation of circumferential WSS, which correlated with markedly increased peak aortic valve velocity (p<0.01).

Conclusions

The location of peak aortic WSS and type of aortopathy remained homogeneous among R-L BAV patients irrespective of valve dysfunction. Severe aortic insufficiency or stenosis resulted in further elevated aortic WSS and exaggerated flow eccentricity.

Keywords: Bicuspid aortic valve, magnetic resonance imaging, wall shear stress

Central Picture

graphic file with name nihms857445u1.jpg

Wall shear stress distribution features in BAV insufficiency and stenosis.

Central Message

Hemodynamic alterations revealed by 4D flow MRI in BAV subjects indicated additional aortic WSS elevation and flow eccentricity exaggeration due to severe aortic insufficiency or aortic stenosis.

Perspective Statement

BAV patients with aortic insufficiency tended to suffer from a higher risk for progressive ascending aorta dilatation and adverse aortic events after isolated aortic valve replacement surgery compared to their aortic stenosis counterparts. Spatiotemporal characteristics of distorted flow in the setting of aortic valve dysfunction, which could have long-term consequences in affected aortic wall tissue, and hemodynamic markers derived from MRI metrics represent promising developments towards establishing non-invasive indicators for risk stratification and management of BAV patients. c 2017 Published by The American Association for Thoracic Surgery.

Introduction

Bicuspid aortic valve (BAV), the most common congenital cardiac disorder in adults, is associated with a heterogeneous expression of aortic diseases such as ascending aortic dilatation, aneurysm, and dissection.14 Both genetic and hemodynamic origins of these complications have been proposed and there exists a “fate versus flow” controversy regarding the development of BAV aortopathy.5 As a result, the inherent heterogeneity of BAV aortopathy is currently not fully integrated into the existing knowledge infrastructure and patient management. The constantly changing practice guidelines for BAV aortopathy also need to be revised and redirected into the realm of individualized decision-making.6, 7 Therefore, collective efforts, e.g. as proposed by the International Bicuspid Aortic Valve Consortium (BAVCon),8 should be made to address the variability in genetic basis, hemodynamics, and aortic wall extracellular matrix abnormalities to meet the contemporary focus on precision medicine.

Time-resolved 3-dimensional magnetic resonance imaging (4D flow MRI) offers a novel approach to assess hemodynamic alterations in BAV.9 Previous studies have shown that BAV and its cusp fusion type can lead to distinct changes in systolic aortic outflow and wall shear stress (WSS) distribution patterns, resulting in different regional histology, proteolytic activity, and unfavorable ascending aortic remodeling.1013 It has been demonstrated in recent cohort studies that BAV patients with aortic insufficiency tended to suffer from a higher risk for progressive ascending aorta dilatation and adverse aortic events after isolated aortic valve replacement surgery compared to their aortic stenosis counterparts.1416 However, there is limited data on systolic aortic outflow and WSS distribution as a function of aortic valve dysfunction such as stenosis or insufficiency.

The present study performed 4D flow MRI in right-left (R-L) cusp fusion type BAV patients with severe aortic stenosis (AS) or insufficiency (AI), and compared 3D aortic outflow pattern, WSS and WSS eccentricity to BAV control and TAV control subjects of similar aortic sizes. Our aim was to investigate the hypothesis that aortic valve dysfunction exert additional but distinct alterations on systolic aortic outflow and WSS distribution patterns in BAV ascending aorta, which might be attributed to characteristic physiological changes of AS and AI, and could facilitate individualized surgical strategies for BAV aortopathy.

Methods

Study population

BAV patients with an R-L cusp fusion type were screened from the cardiology clinic of our institution by transthoracic echocardiography and recruited for 4D flow MRI from December 2014 to February 2016. BAV subjects were categorized into 3 groups according to their aortic valve function as follows: BAV patients with no more than mild aortic stenosis or insufficiency (BAV-CTL group, n=20); BAV patients with severe aortic insufficiency but no more than mild aortic stenosis (BAV-AI group, n=15); BAV patients with severe aortic stenosis but no more than mild aortic insufficiency (BAV-AS group, n=15). Age- and aortic size-matched volunteers with tricuspid aortic valve and no more than mild aortic stenosis or insufficiency were recruited as controls (TAV-CTL group, n=15). According to ACC/AHA practice guidelines,17 severe aortic insufficiency was defined as jet width/LVOT above 65% or vena contracta above 0.6 or regurgitant fraction greater than 50%; severe aortic stenosis was defined as mean transaortic pressure gradient above 40 mmHg or aortic valve area less than 1.0cm2. Exclusion criteria consisted of previous cardiac surgery, infective endocarditis, acute aortic dissection, or other severe congenital cardiac defects (namely coarctation of the aorta, tetralogy of Fallot, ventricular septal defect, and supra-aortic stenosis). The present study conformed to the principles outlined in the Declaration of Helsinki and was approved by the ethics committee of Zhongshan Hospital Fudan University, Shanghai, China.

Echocardiography

Transthoracic echocardiographic images were acquired in all subjects with a commercially available system (iE33, Philips Medical Systems, Bothell WA, USA). Two-dimensional and Doppler echocardiography were performed at rest in the left lateral decubitus position according to a uniform and standardized protocol based on the ACC/AHA practice guidelines and ASE recommendations.17, 18 All image data were analyzed by an experienced echocardiologist blinded to the results of the MRI study. The diagnosis of BAV and cusp fusion type was confirmed in accordance to Sievers’ classification19 by transthoracic or transesophageal echocardiography in a short-axis view of the aortic valve with only two valve cusps clearly identified. Peak aortic valve velocity and mean transvalvular gradient were assessed by continuous-wave Doppler echocardiography in the apical long-axis and five-chamber view, and aortic valve area was calculated via the continuity equation. Aortic regurgitation was graded according to the standard methods by color Doppler in the parasternal long-axis and short-axis view as well as in the apical long-axis and five-chamber view.

Magnetic resonance imaging

All subjects underwent cardiac MRI on a commercially available 3.0 Tesla system (Verio, Siemens Medical Systems, Erlangen, Germany). Aortic diameters at the level of aortic sinus, sinotubular junction, mid ascending, and proximal descending aorta at the level of the pulmonary artery were obtained from axial half-Fourier single-shot turbo spin-echo scan sequence imaging of the thorax. Dilatation of aortic segments (root, ascending aorta, and transverse arch) was defined as diameter >40mm.20 In addition, the phenotype of BAV aortopathy was categorized as follows: type 0, normal aorta; type 1, dilated only at the aortic root; type 2, aortic enlargement involving the tubular portion of ascending aorta; type 3, diffuse involvement of both the entire ascending aorta and the transverse aortic arch.11 The assessment of aortic blood flow was facilitated by 4D flow MRI with three-directional velocity encoding. Data were acquired during free breathing using respiratory and prospective ECG gating in a sagittal oblique 3D volume covering the entire thoracic aorta. Pulse sequence parameters were as follows: flip angle =7°, spatial resolution =(2.2–2.6)×(1.8–2.1)×(2.2–2.5) mm3, temporal resolution =40.8ms. Velocity encoding was adjusted to minimize velocity aliasing ranging from 150 to 400cm/s based on the three-chamber view of in-plane standard 2D phase-contrast MRI scout measurements. 4D flow MRI acquisition time varied from 12 to 20 minutes depending on navigator efficiency and individual heart rate.

4D flow data analysis

4D flow MRI preprocessing included noise filtering, correction for eddy currents and velocity aliasing with custom-built software programmed in Matlab (The MathWorks Inc., MA, USA). 3D PC magnetic resonance angiography was derived from 4D flow MRI data and used to visualize 3D aortic flow patterns by velocity-coded vectors and streamlines (EnSight, CEI, Apex, NC, USA) at peak flow systole. Measurement planes were manually placed perpendicular to the long axis of the aorta at defined anatomic landmarks in the proximal ascending aorta directly distal to the sinotubular junction, mid-ascending aorta, distal ascending aorta at the origin of the brachiocephalic trunk, and proximal descending aorta (Figure 1) based on previously published criteria.11 Aortic lumen contours were manually delineated at all time frames with the use of customized Matlab software to calculate peak velocity and time-resolved WSS distribution. Systolic WSS was calculated in 8 anatomic positions (A, anterior; LA, left anterior; L, left; LP, left posterior; P, posterior; RP, right posterior; R, right; and RA, right anterior) and averaged over the proceeding and 4 subsequent time steps after the peak systolic flow. Standard deviation of circumferential WSS across 8 anatomic positions (WSS-SD8P) and ratio of WSS between the maximum and minimum position (ratio WSSmax-min) at each measurement plane were calculated as previously described (Appendix A). As confirmed from the maximum RA-LP WSS values in the healthy control populations, a WSS eccentricity threshold defined as RA-LP >0.2 N/m2 was used to categorize the flow as eccentric.10 Circumferentially averaged WSS was calculated as the mean over all eight positions. WSS measurements were repeated in 20 subjects (10 TAV volunteers, 10 BAV patients) one week later to assess the reproducibility. The intraclass correlation coefficients between two measurements for systolic WSS, WSS-SD8P, and ratio WSSmax-min were 0.73, 0.78, and 0.63, respectively.

Figure 1. Representative Images and Analytical Planes for 4D Flow MRI.

Figure 1

AAo indicated ascending aorta; and DAo, descending aorta.

Statistical analysis

Analysis was performed with SPSS 12.0 software (Chicago IL, USA). Data were reported as mean±SD or medians (interquartile ranges) for continuous variables and as frequencies (percentages) for categorical variables. The Shapiro-Wilk test was used to evaluate the normal distribution of continuous parameters. Differences between two groups were assessed by the Student t test (Gaussian distribution) or Mann-Whitney U-test (non-Gaussian distribution). Multiple comparisons were analyzed using one-way ANOVA (Gaussian distribution) or Kruskal-Wallis H analysis (non-Gaussian distribution). Differences in percentages were evaluated using the chi-square tests or Fisher’s exact tests. Correlation was assessed by Pearson’s correlation coefficient. The level of significance for pairwise comparisons was adjusted when multiple comparisons were performed (p=0.05/4=0.0125). Statistical significance was defined as 2-sided p<0.05.

Results

Baseline characteristics

BAV patients demonstrated similar aortic diameter as well as distribution of gender, comorbid condition, and medication status. Compared to BAV-CTL group, the BAV-AI group had elevated stroke volume (p<0.001), higher systolic blood pressure (p=0.002), greater transvalvular pressure gradient (p=0.002), and increased aortic sinus diameter (p=0.020). The BAV-AS group demonstrated a marked reduction in aortic valve area (p<0.001), higher peak aortic valve velocity (p<0.001), greater transvalvular pressure gradient (p<0.001), and older age (p=0.005). (Table 1)

Table 1.

Baseline Characteristics of R-L BAV Patients and TAV Volunteers

Control Group
Study Group
TAV-CTL BAV-CTL BAV-AI BAV-AS
n (female) 15 (6) 20 (6) 15 (2) 15 (7)
Age, years 51 ±9 47 ±11 46 ±12 57 ±7
Body surface area, m2 1.78 ±0.12 1.79 ±0.11 1.79 ±0.13 1.76 ±0.12
Comorbid conditions, n (%)
 Hypertension 3 (20.0) 3 (15.0) 3 (20.0) 2 (13.3)
 Diabetes 1 (6.7) 0 0 1 (6.7)
 History of coronary artery disease 0 0 0 1 (6.7)
Systolic blood pressure, mmHg 124 ±10 122 ±11 138 ±15 126 ±10
Diastolic blood pressure, mmHg 76 ±9 75 ±9 71 ±13 76 ±9
Beta-blocker therapy, n (%) 0 3 (15.0) 2 (13.3) 2 (13.3)
ACEI/ARB therapy, n (%) 0 0 2 (13.3) 2 (13.3)
LV ejection fraction(%) 63.1 ±3.7 63.9 ±4.9 60.7 ±6.3 62.0 ±4.7
Aortic valve features
 Aortic valve area, cm2 2.5 (2.4–2.7) 2.4 (2.2–2.6) 2.6 (2.4–2.8) 0.8 (0.7–0.9)
 Peak velocity, m/s 1.4 ±0.1 1.7 ±0.4 2.1 ±0.4 4.6 ±0.7
 Mean gradient, mmHg 5.4 (3.8–6.2) 6.3 (5.0–8.0) 10.2 (7.2–12.0) 46.1 (41.8–57.3)
Stroke volume, ml 54.3 ±7.5 55.3 ±7.9 107.3 ±13.8 59.1 ±5.7
Aortic diameters, mm
Aortic sinus 33.9 ±3.3 34.6 ±3.2 38.0 ±4.3 34.1 ±3.1
Sinotubular junction 29.8 ±3.7 30.9 ±3.5 31.8 ±4.0 30.2 ±3.3
Mid ascending aorta 38.8 ±4.8 39.8 ±5.1 40.4 ±5.8 41.0 ±5.3
Proximal descending aorta 23.4 ±3.2 24.4 ±3.1 23.3 ±2.4 22.5 ±2.6
Aortopathy, n (%)
 Type 0 8 (53.3) 10 (50.0) 6 (40.0) 7 (46.7)
 Type 1 1 (6.7) 1 (5.0) 1 (6.7) 0
 Type 2 5 (33.3) 8 (40.0) 7 (46.7) 7 (46.7)
 Type 3 1 (6.7) 1 (5.0) 1 (6.7) 1 (6.7)

All continuous data are presented as mean ±standard deviation, or as median (interquartile range). TAV indicates tricuspid aortic valve; BAV, bicuspid aortic valve; CTL, control; AI, aortic insufficiency; and AS, aortic stenosis.

indicates significant differences compared with BAV controls (p<0.0125 after Bonferroni correction).

Type 2 aortopathy, defined as aortic enlargement involving the tubular portion of ascending aorta, was the most prevalent phenotype among BAV patients with dilated ascending aorta (82%, 22/27), followed by type 3 (11%, 3/27) and type 1 (7%, 2/27). The distribution of aortopathy phenotypes was similar among all 3 BAV groups.

Systolic aortic outflow patterns

Representative 4D flow MRI images for systolic 3D blood flow visualization and analysis plane placement are shown in Figure 1. Examples for typical flow patterns observed for the different patient groups are shown in Figure 2. TAV volunteers showed a central flow jet and cohesive streamlines directing blood flow parallel to the vessel wall, which indicated high velocity vectors centering the majority of vessel lumen and decreasing in velocity when approaching vessel wall. On the other hand, BAV patients demonstrated eccentric outflow jets accompanied by helical streamlines extending from aortic root to the origin of aortic arch. These flow patterns contributed to altered flow impingement zones along the ascending aorta and a skewed distribution of systolic velocity vectors. (Video 1) For the BAV-AI group, the velocity distribution within ascending aorta was similar to that of BAV-CTL group but with a universal elevation. For the BAV-AS group, highly eccentric velocity distribution was observed.

Figure 2. Flow Patterns Visualization.

Figure 2

Three-dimensional (3D) streamline visualization of peak systolic flow in a BAV patient of R-L fusion type with no more than mild aortic dysfunction (BAV-CTL, Middle) in comparison with an aortic size-matched TAV volunteer (TAV-CTL, Top). Note the presence of distinct 3D outflow jet directing towards the right-anterior wall of ascending aorta via right-handed helix (black dashed arrows) in the R-L BAV subject. Bottom panels showed 3D velocity-coded vectors with uniform velocity limit of 1.2m/s in BAV patients with severe aortic insufficiency (BAV-AI), severe aortic stenosis (BAV-AS), BAV-CTL, and TAV-CTL at mid-ascending aorta. Different distributions of high velocity vectors can be appreciated between groups in correspondence to differential exertion of shear forces. BAV indicates bicuspid aortic valve; TAV, tricuspid aortic valve; R-L, right and left coronary cusp fusion type; A, anterior; LA, left anterior; L, left; LP, left posterior; P, posterior; RP, right posterior; R, right; and RA, right anterior.

WSS patterns and flow eccentricity assessment

Circumferentially averaged WSS was significantly elevated in the BAV-CTL group compared to the TAV-CTL group at the level of the proximal (p=0.010) and mid-ascending aorta (p=0.009). The location of peak systolic WSS migrated along a right-handed helix among all BAV patients, from the right-anterior of proximal ascending aorta (BAV vs. TAV: 0.91±0.23 N/m2 vs. 0.43±0.12 N/m2, p<0.001) towards left-anterior at the supra-aortic level (BAV vs. TAV: 0.76±0.20 N/m2 vs. 0.44±0.07 N/m2, p<0.001). (Table 2, Figure 3)

Table 2.

Hemodynamic Qualification at Measurement Planes

Control Group
Study Group
TAV-CTL BAV-CTL BAV-AI BAV-AS
Cardiac stroke volume, ml/beat 54.3 ±7.5 55.3 ±7.9 107.3 ±13.8 59.1 ±5.7
Systolic WSS, N/m2
 Proximal ascending aorta 0.44 ±0.06 0.53 ±0.11 0.69 ±0.10 0.65 ±0.11
 Mid-ascending aorta 0.44 ±0.07 0.57 ±0.09 0.75 ±0.12 0.70 ±0.11
 Distal ascending aorta 0.43 ±0.06 0.48 ±0.08 0.69 ±0.15 0.61 ±0.08
 Proximal descending aorta 0.42 ±0.05 0.46 ±0.07 0.47 ±0.05 0.48 ±0.10
WSS eccentricity, n (%) 0 14 (70.0) 11 (73.3) 15 (100.0)
WSS-SD8P, N/m2
 Proximal ascending aorta 0.08 ±0.02 0.14 ±0.05 0.14 ±0.04 0.22 ±0.07
 Mid-ascending aorta 0.08 ±0.02 0.15 ±0.05 0.14 ±0.05 0.23 ±0.07
 Distal ascending aorta 0.05 ±0.01 0.06 ±0.02 0.06 ±0.02 0.17 ±0.05
 Proximal descending aorta 0.05 ±0.01 0.05 ±0.01 0.05 ±0.01 0.05 ±0.01
Ratio WSSmax-min
 Proximal ascending aorta 1.61 (1.53–1.79) 2.08 (1.82–2.41) 1.86 (1.44–2.22) 3.00 (2.24–4.29)
 Mid-ascending aorta 1.65 (1.50–2.07) 2.36 (1.75–3.05) 1.76 (1.61–2.16) 3.35 (2.92–4.08)
 Distal ascending aorta 1.43 (1.33–1.53) 1.51 (1.38–1.73) 1.30 (1.23–1.45) 2.62 (2.32–3.99)
 Proximal descending aorta 1.44 (1.34–1.65) 1.40 (1.33–1.49) 1.43 (1.34–1.50) 1.44 (1.38–1.55)

All continuous data are presented as mean ±standard deviation, or as median (interquartile range). TAV indicates tricuspid aortic valve; BAV, bicuspid aortic valve; CTL, control; AI, aortic insufficiency; AS, aortic stenosis; WSS-SD8P, standard deviation of circumferential WSS across 8 anatomic positions; and ratio WSSmax-min, ratio of WSS between the maximum and minimum position.

indicates significant differences compared with BAV controls (p<0.0125 after Bonferroni correction).

Figure 3. Segmental Systolic Wall Shear Stress Measurements.

Figure 3

Segmental systolic wall shear stress (WSS) measurements were displayed across 8 anatomic positions (A, anterior; LA, left anterior; L, left; LP, left posterior; P, posterior; RP, right posterior; R, right; and RA, right anterior) at proximal ascending aorta, mid-ascending aorta, distal ascending aorta, and proximal descending aorta. Error bars represent standard deviation of individual WSS variation. Asterisks indicate statistical significance (p<0.0125 after Bonferroni correction) for pairwise comparison among 4 groups. AAo indicated ascending aorta; and DAo, descending aorta.

The patterns of WSS distribution along the ascending aorta were distinctly different between BAV-AI and BAV-AS groups. Compared with the BAV-CTL group, the BAV-AI group demonstrated a marked elevation of systolic WSS in all 8 positions for all three analysis planes in the ascending aorta (all p<0.01). Circumferentially averaged WSS at level of proximal, middle and distal ascending aorta were positively correlated with cardiac stroke volume (r=0.62, p=0.014; r=0.74, p=0.002; r=0.68, p=0.005; respectively), but not with age, systolic blood pressure, or aortic sinus diameter (all p>0.05). Parameters for flow eccentricity including WSS-SD8P and WSSmax-min ratio were similar to those in the BAV-CTL group (all p>0.10). For the BAV-AS group, regional WSS was only elevated in selected positions, resulting in a highly skewed systolic WSS distribution with elevated WSS-SD8P and WSSmax-min ratio (both p<0.005). (Table 2, Figure 3) Based on the WSS eccentricity threshold defined as RA-LP >0.2 N/m2 at the level of mid-ascending aorta, eccentric WSS distribution was most frequently observed in the BAV-AS group (0.62±0.22 N/m2, 100%), followed by the BAV-CTL (0.35±0.17 N/m2, 70.0%) and BAV-AI groups (0.32±0.19 N/m2, 73.3%). Positive correlations were found between aortic diameter and WSS-SD8P at the level of mid-ascending aorta for both the BAV-CTL (r=0.56, p=0.010) and BAV-AI group (r=0.68, p=0.006). In addition, there was a positive correlation between WSS-SD8P with peak aortic valve velocity (r=0.92, p<0.001) but not with aortic diameter (r=0.12, p=0.68) at the same level in BAV-AS group. (Figure 4) All WSS values and distributions were similar among 3 BAV groups at the level of proximal descending aorta.

Figure 4. Relevant Parameters for WSS Deviation.

Figure 4

Correlation analyses were performed between aortic diameter and WSS-SD8P at the level of mid-ascending aorta in BAV-CTL, BAV-AI, and BAV-AS patients. Positive correlation was found between peak aortic valve velocity and WSS-SD8P at mid-ascending aorta in BAV-AS patients. WSS-SD8P indicated standard deviation of circumferential wall shear stress across 8 anatomic positions.

Discussion

Among the most hazardous complications of BAV, aortopathy attracts both academic and clinical attention for its problematic consequences, intricate management, and relatively unpredictable natural history. From 1998 to 2014, nearly a dozen international guidelines have been issued on the threshold for surgical intervention in BAV aortopathy, initiating at a recommended threshold of 5.0–5.5cm in 1997,21,22 peaking at a nadir of 4.0–5.0cm in 2010,23 then retreating back to 4.5–5.5cm in 2014.24 Complicating these matters, the shifting criteria are echoed by marked gaps in knowledge and attitudes among cardiovascular surgeons on the management of BAV aortopathy, including poor adherence to the current guidelines.25 Since the majority of BAV patients are likely to require surgical correction for valve dysfunction in their life, it is vital to reach a uniform consensus on concomitant surgical intervention strategy in BAV patients with significant aortic insufficiency or stenosis. The present study concentrated exclusively on these BAV patients and for the first time, provided convincing evidence to support the hypothesis that aortic valve dysfunction exert additional but apparently different effects on ascending aorta.

Four-dimensional flow MRI, which permits in-vivo assessment of time-resolved 3D blood velocity and enables quantification of complex 3D blood flow pattern in the aorta, provides a comprehensive approach to appreciate the role of hemodynamics in BAV aortopathy. Previous studies have validated the significant differences in systolic aortic flow and WSS patterns between R-L and right-noncoronary (R-N) BAV patients.10, 11 Since those with moderate-to-severe aortic insufficiency accounted for less than 10% in R-N BAV patients,16, 26, 27 we chose R-L BAV patients as the study population for further categorization based on valve function. We found it similar to previous reports that R-L BAV patients tended to exhibit peak WSS at the right-anterior or anterior position of ascending aorta, which progressed along a right-handed helical aortic outflow until the level of supra-aortic artery. Notably, the above positions of peak WSS along the ascending aorta did not change or exhibit a distinct alteration for the severe aortic insufficiency or stenosis cases. The predominance of type 2 aortopathy also persisted, with or without severe valve dysfunction. Based on previous methods which measure systolic WSS as an average over multiple systolic time points to mitigate measurement noise, the magnitude of circumferentially averaged WSS in our study (R-L BAV-CTL: 0.5 ±0.1 N/m2; TAV-CTL: 0.4 ±0.1 N/m2) was similar to those previously reported by Mahadevia et al.11 (R-L BAV-CTL: 0.6 N/m2; TAV-CTL: 0.3–0.4 N/m2) and Meierhofer et al.28 (BAV: median 0.6 N/m2; TAV-CTL: median 0.5 N/m2).

The malformed BAV impacts aortic hemodynamics predominantly by altering the direction of outflow jets, which no longer comply with the aortic curvature and result in eccentric WSS distribution along the aortic vessel wall. Aortic valve dysfunction, namely insufficiency and stenosis, are hypothesized to exert additional but apparently different effects on ascending aorta. For example, regurgitation leads to higher stroke volumes and global aortic outflow velocities, while stenosis creates eccentric high-velocity flow jets and regional ascending aortic WSS elevation.2 The present study utilized 4D Flow hemodynamics to describe the composite effect of BAV and AI/AS upon ascending aorta, and unprecedentedly, to advocate this hypothesis in the R-L BAV scenario. To further elaborate, the BAV-AI patients experienced an increased stroke volume, thereby ejecting a larger stroke bolus, which manifested in the form of a universal WSS increase around the ascending aorta instead of exaggerated eccentricity. Aside from age, systolic blood pressure, and aortic sinus diameter, cardiac stroke volume was mostly likely to be accounted for the elevation of circumferentially averaged WSS. Alternatively, for BAV-AS patients, the diminished aortic valve area and elevated flow velocity further exacerbated the eccentricity of aortic outflow,29, 30 thus leading to a high WSS-SD8P and WSSmax-min ratio.

The divergence of WSS expression between BAV-AI and BAV-AS patients reflected the spatiotemporal characteristics of distorted flow in the setting of aortic valve dysfunction, which could have long-term consequences in affected aortic wall tissue. It was argued by Guzzardi et al.12 that WSS might propel changes in local extracellular matrix homeostasis and ascending aortic wall structure. In aortic regions with elevated WSS, elastin content and structure were severely disrupted compared with distal regions presenting normal WSS. Pathology studies also found worse elastic fiber loss in aortic wall tissue of BAV-AI patients,31, 32 which is in accordance with clinical observations that BAV-AI patients, especially those with predominantly sinus dilatation (so-called “root phenotype”), suffered from faster ascending aorta dilatation and higher risk for adverse aortic events even after aortic valve replacement.1315, 3335 In advent of above evidences, an aggressive policy of preventive aortic intervention might be appreciated in BAV-AI patients who exhibit a uniform WSS elevation around the lumen of the ascending aorta, and who are also known to present at a younger age and with the “root phenotype”. Meanwhile, BAV-AS patients who exhibit exaggerated flow eccentricity and elevation of regional WSS could benefit from less aggressive treatment strategies including reduction aortoplasty guided by WSS mapping. It was supported by long-term follow-up studies that clinical outcomes of reduction aortoplasty might rely on the extent of localized degeneration of the aortic wall at the greater curvature,36, 37 which was typically associated with BAV stenosis. Considering the elder age of BAV-AS patients, the less aggressive approach of reduction aortoplasty could be a surgical option for future clinical studies since it was associated with lower rate of early postoperative complications as well as shorter ICU and hospital stay.38, 39

Great efforts have been made to explore ideal quantitative metrics of BAV aortic hemodynamics generated by cardiac magnetic resonance (CMR) to serve as novel risk markers and potential prognostic indicators to better address individual risk stratification in BAV aortopathy.40 Hope et al.41, 42 found promising correlation between ascending aortic growth rates and flow eccentricity. Considering the time constraint and technical complexity in WSS quantification, subsequent studies preferred simpler CMR metrics, namely flow displacement, restrictive leaflet excursion, and angle between the experimental flow vector and theoretical axis of left ventricular outflow, to classic WSS quantification in BAV scenario.11, 4345 To better describe shear forces which had well-recognized effects on vascular function and diseases, our study directly utilized standard deviations of circumferential WSS to reflect flow eccentricity, which increased with ascending aortic diameters in non-stenotic BAV patients and with peak aortic valve velocity in stenotic cases. Further endeavors as multi-centered collaborations should be conveyed to determine the CMR hemodynamic metrics applicable for cardiovascular surgeons to balance the benefit and risk of preventive aortic intervention among BAV patients, especially which WSS pattern conferred increased dissection risk and what degree of WSS elevation indicated surgical intervening even if ascending aorta did not reach 5.5cm yet.

Study Limitations

The present study should be appreciated with knowledge of its limitations, such as relatively small subject number and exclusion of cases other than R-L cusp fusion type. It should be noted that the results presented in this article have not been adjusted for blood pressure, age or other patient characteristics, and further studies are warranted to systemically investigate the combined influence of BSA, blood pressure and age on the metrics of aortic hemodynamics. Although satisfying data reproducibility was achieved via standardized acquisition and analysis protocols, the technical challenges associated with 4D flow MRI include limited spatial resolution, partial volume effects, and numerical derivation of the velocity field.5 The time-consuming acquiring and analyzing process is still a major obstacle for its clinical availability. Computational fluid dynamics is a complementary tool with its own challenges.30 Nonetheless, it is a perfect tool to investigate those parameters such as helicity and oscillatory shear index which we can’t easily measure with MRI. Furthermore, in-depth analysis of pathological and gene-expressing profiles within ascending aortic tissue would help to integrate hemodynamic and genetic knowledge into a complete working tool kit to put better interpretation of the scale in WSS increments on biomechanical changes of actual aortic tissue, and possibly, to predict BAV aortopathy. Longitudinal studies are needed to understand restoration of hemodynamics and additional aberrations after valve surgery, which is crucial for precise patient management. A detailed paradigm of BAV phenotypes and their association with clinical hazards for aortopathy could benefit interventional strategies, and in the process remodel our perception of this highly heterogeneous entity.

Conclusions

On the basis of skewed WSS distribution in R-L BAV patients, 4D flow MRI revealed marked hemodynamic alterations in the ascending aorta of BAV-AI and BAV-AS subjects. In proportion to increased stroke volume, a universal elevation of WSS was found at the vessel wall in BAV-AI patients. On the contrary, an increased WSS burden was found in BAV-AS cases in the form of a focal elevation of flow eccentricity due to diminished valve area and accelerated flow velocity. Hemodynamic markers derived from CMR metrics represent promising developments towards establishing non-invasive indicators for risk stratification and management of BAV patients.

Supplementary Material

1. Video 1 Three-dimensional Streamline visualization.

Highly eccentric outflow jet pattern was found in the BAV patient in comparison with cohesive streamlines parallel to the vessel wall in the TAV-control patient.

Download video file (1.7MB, mp4)

Acknowledgments

The authors wish to thank Dr. Caixia Fu from Siemens Shenzhen Magnetic Resonance for her assistance in MRI data acquiring.

Sources of Funding: The study was funded by National Natural Science Foundation of China grant No. 81300232 (Dr. Y Wang), Shanghai Municipal Committee of Science and Technology grant No. 16ZR1433100 (Dr. X Wang), Shanghai Municipal Health Bureau grant No. 20154Y0030 (Dr. Y Wang), National Institute of Health (NIH) National Heart, Lung, and Blood Institute (NHLBI) grants R01HL115828 (Dr. Markl) and K25HL119608 (Dr. Barker).

Abbreviations and acronyms

BAV

bicuspid aortic valve

TAV

tricuspid aortic valve

WSS

wall shear stress

CTL

control

AS

aortic stenosis

AI

aortic insufficiency

4D

4-dimensional

MRI

magnetic resonance imaging

WSS-SD8P

standard deviation of circumferential WSS across 8 anatomic positions

Ratio WSSmax-min

ratio of WSS between the maximum and minimum position

Appendix A

Formulation of Wall Shear Stress

Wall shear stress (WSS) depends on the spatial velocity gradient at the vessel wall, therefore can be calculated from the 3-directional velocity fields measured by 4D flow MRI.1 It should be noted that the term “WSS” is used to describe WSS estimations based on the interpolation of local velocity derivatives onto the manually drawn vessel lumen contours as described by Stalder et al.2 Briefly, B-spline interpolation allows for the calculation of the local blood flow velocity derivatives on the vessel contour and thus allows a direct estimate of time-resolved segmental WSS vectors to be obtained independently of any global assumptions regarding the flow profile.

The WSS vector ( τ) for a Newtonian incompressible fluid can be derived from the velocity field based on the deformation tensor at the vessel wall:

τ=2ηε˙n=η(2n1v1x1+n2(v1x2+v2x1)+n3(v1x3+v3x1)n1(v1x2+v2x1)+2n2v2x2+n3(v2x3+v3x2)n1(v1x3+v3x1)+n2(v2x3+v3x2)+2n3v3x3)

η: viscosity, ε˙: deformation tensor, n: inward unit normal and the deformation tensor, v: velocity components, x: the spatial dimensions; [1,2,3]: 3 orthogonal coordinates.

In order to calculate τ from 2D data with three-directional velocity encoding, it was assumed that the 2D analysis plane was normal to the vessel surface, i.e., n=(n1,n2,0). No flow through the vessel condition was enforced. This implies nvx3=n1v1x3+n2v2x3=0, and finally:

τ=η(2n1v1x1+n2(v1x2+v2x1)n1(v1x2+v2x1)+2n2v2x2n1v3x1+n2v3x2)

which can be used to calculate vectorial WSS from data of transversal planes with three-directional velocity information.

References

  • 1.Markl M, Chan FP, Alley MT, Wedding KL, Draney MT, Elkins CJ, et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging. 2003;17:499–506. doi: 10.1002/jmri.10272. [DOI] [PubMed] [Google Scholar]
  • 2.Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M. Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med. 2008;60:1218–31. doi: 10.1002/mrm.21778. [DOI] [PubMed] [Google Scholar]

Footnotes

Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Conflict of interest: none declared.

References

  • 1.Fedak PW, Verma S, David TE, Leask RL, Weisel RD, Butany J. Clinical and pathophysiological implications of a bicuspid aortic valve. Circulation. 2002;106:900–4. doi: 10.1161/01.cir.0000027905.26586.e8. [DOI] [PubMed] [Google Scholar]
  • 2.Tadros TM, Klein MD, Shapira OM. Ascending aortic dilatation associated with bicuspid aortic valve: pathophysiology, molecular biology, and clinical implications. Circulation. 2009;119:880–90. doi: 10.1161/CIRCULATIONAHA.108.795401. [DOI] [PubMed] [Google Scholar]
  • 3.Wang Y, Wu B, Dong L, Wang C, Shu X. Type A aortic dissection in patients with bicuspid or tricuspid aortic valves: a retrospective comparative study in 288 Chinese patients. Eur J Cardiothorac Surg. 2013;44:172–7. doi: 10.1093/ejcts/ezs613. [DOI] [PubMed] [Google Scholar]
  • 4.Verma S, Siu SC. Aortic dilatation in patients with bicuspid aortic valve. N Engl J Med. 2014;370:1920–9. doi: 10.1056/NEJMra1207059. [DOI] [PubMed] [Google Scholar]
  • 5.Spinale FG, Bolger AF. Fate Versus Flow: Wall Shear Stress in the Aortopathy Associated With Bicuspid Aortic Valves. J Am Coll Cardiol. 2015;66:901–4. doi: 10.1016/j.jacc.2015.07.002. [DOI] [PubMed] [Google Scholar]
  • 6.Opotowsky AR, Perlstein T, Landzberg MJ, Colan SD, O’Gara PT, Body SC, et al. A shifting approach to management of the thoracic aorta in bicuspid aortic valve. J Thorac Cardiovasc Surg. 2013;146:339–46. doi: 10.1016/j.jtcvs.2012.10.028. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Hardikar AA, Marwick TH. The natural history of guidelines: the case of aortopathy related to bicuspid aortic valves. Int J Cardiol. 2015;199:150–3. doi: 10.1016/j.ijcard.2015.06.059. [DOI] [PubMed] [Google Scholar]
  • 8.Prakash SK, Bossé Y, Muehlschlegel JD, Michelena HI, Limongelli G, Della Corte A, et al. A roadmap to investigate the genetic basis of bicuspid aortic valve and its complications: insights from the International BAVCon (Bicuspid Aortic Valve Consortium) J Am Coll Cardiol. 2014;64:832–9. doi: 10.1016/j.jacc.2014.04.073. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Hope MD, Hope TA, Meadows AK, Ordovas KG, Urbania TH, Alley MT, et al. Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns. Radiology. 2010;255:53–61. doi: 10.1148/radiol.09091437. [DOI] [PubMed] [Google Scholar]
  • 10.Barker AJ, Markl M, Bürk J, Lorenz R, Bock J, Bauer S, et al. Bicuspid aortic valve is associated with altered wall shear stress in the ascending aorta. Circ Cardiovasc Imaging. 2012;5:457–66. doi: 10.1161/CIRCIMAGING.112.973370. [DOI] [PubMed] [Google Scholar]
  • 11.Mahadevia R, Barker AJ, Schnell S, Entezari P, Kansal P, Fedak PW, et al. Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy. Circulation. 2014;129:673–82. doi: 10.1161/CIRCULATIONAHA.113.003026. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Guzzardi DG, Barker AJ, van Ooij P, Malaisrie SC, Puthumana JJ, Belke DD, et al. Valve-Related Hemodynamics Mediate Human Bicuspid Aortopathy: Insights From Wall Shear Stress Mapping. J Am Coll Cardiol. 2015;66:892–900. doi: 10.1016/j.jacc.2015.06.1310. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Stephens EH, Hope TA, Kari FA, Kvitting JP, Liang DH, Herfkens RJ, et al. Greater asymmetric wall shear stress in Sievers’ type 1/LR compared with 0/LAT bicuspid aortic valves after valve-sparing aortic root replacement. J Thorac Cardiovasc Surg. 2015;150:59–68. doi: 10.1016/j.jtcvs.2015.04.020. [DOI] [PubMed] [Google Scholar]
  • 14.Girdauskas E, Disha K, Raisin HH, Secknus MA, Borger MA, Kuntze T. Risk of late aortic events after an isolated aortic valve replacement for bicuspid aortic valve stenosis with concomitant ascending aortic dilation. Eur J Cardiothorac Surg. 2012;42:832–8. doi: 10.1093/ejcts/ezs137. [DOI] [PubMed] [Google Scholar]
  • 15.Sievers HH, Stierle U, Mohamed SA, Hanke T, Richardt D, Schmidtke C, et al. Toward individualized management of the ascending aorta in bicuspid aortic valve surgery: the role of valve phenotype in 1362 patients. J Thorac Cardiovasc Surg. 2014;148:2072–80. doi: 10.1016/j.jtcvs.2014.04.007. [DOI] [PubMed] [Google Scholar]
  • 16.Wang Y, Wu B, Li J, Dong L, Wang C, Shu X. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve. Ann Thorac Surg. 2016;101:1707–14. doi: 10.1016/j.athoracsur.2015.10.047. [DOI] [PubMed] [Google Scholar]
  • 17.Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, 3rd, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Thorac Cardiovasc Surg. 2014;148:e1–e132. doi: 10.1016/j.jtcvs.2014.05.014. [DOI] [PubMed] [Google Scholar]
  • 18.Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015;28:1–39. doi: 10.1016/j.echo.2014.10.003. [DOI] [PubMed] [Google Scholar]
  • 19.Sievers HH, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg. 2007;133:1226–33. doi: 10.1016/j.jtcvs.2007.01.039. [DOI] [PubMed] [Google Scholar]
  • 20.Erbel R, Alfonso F, Boileau C, Dirsch O, Eber B, Haverich A, et al. Diagnosis and management of aortic dissection. Eur Heart J. 2001;22:1642–81. doi: 10.1053/euhj.2001.2782. [DOI] [PubMed] [Google Scholar]
  • 21.Kouchoukos NT, Dougenis D. Surgery of the thoracic aorta. N Engl J Med. 1997;336:1876–88. doi: 10.1056/NEJM199706263362606. [DOI] [PubMed] [Google Scholar]
  • 22.Coady MA, Rizzo JA, Hammond GL, Mandapati D, Darr U, Kopf GS, et al. What is the appropriate size criterion for resection of thoracic aortic aneurysms? Thorac Cardiovasc Surg. 1997;113:476–91. doi: 10.1016/S0022-5223(97)70360-X. [DOI] [PubMed] [Google Scholar]
  • 23.Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE, Jr, et al. 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with Thoracic Aortic Disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Circulation. 2010;121:e266–369. doi: 10.1161/CIR.0b013e3181d4739e. [DOI] [PubMed] [Google Scholar]
  • 24.Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, 3rd, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Thorac Cardiovasc Surg. 2014;148:e1–e132. doi: 10.1016/j.jtcvs.2014.05.014. [DOI] [PubMed] [Google Scholar]
  • 25.Verma S, Yanagawa B, Kalra S, Ruel M, Peterson MD, Yamashita MH, et al. Knowledge, attitudes, and practice patterns in surgical management of bicuspid aortopathy: a survey of 100 cardiac surgeons. J Thorac Cardiovasc Surg. 2013;146:1033–40. doi: 10.1016/j.jtcvs.2013.06.037. [DOI] [PubMed] [Google Scholar]
  • 26.Kang JW, Song HG, Yang DH, Baek S, Kim DH, Song JM, et al. Association between bicuspid aortic valve phenotype and patterns of valvular dysfunction and bicuspid aortopathy: comprehensive evaluation using MDCT and echocardiography. JACC Cardiovasc Imaging. 2013;6:150–61. doi: 10.1016/j.jcmg.2012.11.007. [DOI] [PubMed] [Google Scholar]
  • 27.Sievers HH, Stierle U, Hachmann RM, Charitos EI. New insights in the association between bicuspid aortic valve phenotype, aortic configuration and valve haemodynamics. Eur J Cardiothorac Surg. 2016;49:439–46. doi: 10.1093/ejcts/ezv087. [DOI] [PubMed] [Google Scholar]
  • 28.Meierhofer C, Schneider EP, Lyko C, Hutter A, Martinoff S, Markl M, et al. Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study. Eur Heart J Cardiovasc Imaging. 2013;14:797–804. doi: 10.1093/ehjci/jes273. [DOI] [PubMed] [Google Scholar]
  • 29.Bissel MM, Hess AT, Biasiolli L, Glaze SJ, Loudon M, Pitcher A, et al. Aortic dilation in bicuspid aortic valve disease: flow pattern is a major contributor and differs with valve fusion type. Circ Cardiovasc Imaging. 2013;6:499–507. doi: 10.1161/CIRCIMAGING.113.000528. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Youssefi P, Gomez A, He T, Anderson L, Bunce N, Sharma R, et al. Patient-specific computational fluid dynamics—assessment of aortic hemodynamics in a spectrum of aortic valve pathologies. J Thorac Cardiovasc Surg. 2016 doi: 10.1016/j.jtcvs.2016.09.040. [published online by the publisher] http://dx.doi.org/10.1016/j.jtcvs.2016.09.040. [DOI] [PubMed]
  • 31.Roberts WC, Vowels TJ, Ko JM, Filardo G, Hebeler RF, Jr, Henry AC, et al. Comparison of the structure of the aortic valve and ascending aorta in adults having aortic valve replacement for aortic stenosis versus for pure aortic regurgitation and resection of the ascending aorta for aneurysm. Circulation. 2011;123:896–903. doi: 10.1161/CIRCULATIONAHA.110.972406. [DOI] [PubMed] [Google Scholar]
  • 32.Girdauskas E, Rouman M, Borger MA, Kuntze T. Comparison of aortic media changes in patients with bicuspid aortic valve stenosis versus bicuspid valve insufficiency and proximal aortic aneurysm. Interact Cardiovasc Thorac Surg. 2013;17:931–6. doi: 10.1093/icvts/ivt406. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Roberts WC. Prophylactic replacement of a dilated ascending aorta at the time of aortic valve replacement of a dysfunctioning congenitally unicuspid or bicuspid aortic valve. Am J Cardiol. 2011;108:1371–2. doi: 10.1016/j.amjcard.2011.08.016. [DOI] [PubMed] [Google Scholar]
  • 34.Della Corte A, Bancone C, Buonocore M, Dialetto G, Covino FE, Manduca S, et al. Pattern of ascending aortic dimensions predicts the growth rate of the aorta in patients with bicuspid aortic valve. JACC Cardiovasc Imaging. 2013;6:1301–10. doi: 10.1016/j.jcmg.2013.07.009. [DOI] [PubMed] [Google Scholar]
  • 35.Detaint D, Michelena HI, Nkomo VT, Vahanian A, Jondeau G, Sarano ME. Aortic dilatation patterns and rates in adults with bicuspid aortic valves: a comparative study with Marfan syndrome and degenerative aortopathy. Heart. 2014;100:126–34. doi: 10.1136/heartjnl-2013-304920. [DOI] [PubMed] [Google Scholar]
  • 36.Tsamis A, Phillippi JA, Koch RG, Chan PG, Krawiec JT, D’Amore A, et al. Extracellular matrix fiber microarchitecture is region-specific in bicuspid aortic valve-associated ascending aortopathy. J Thorac Cardiovasc Surg. 2016;151:1718–1728.e5. doi: 10.1016/j.jtcvs.2016.02.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Fedak PW, Guzzardi DG. Real estate of the bicuspid aorta: Location, location, location! J Thorac Cardiovasc Surg. 2016;151:1728–9. doi: 10.1016/j.jtcvs.2016.02.048. [DOI] [PubMed] [Google Scholar]
  • 38.Della Corte A, De Feo M, Bancone C, Provenzano R, Giordano S, Buonocore M, et al. Long-term follow-up of reduction ascending aortoplasty with autologous partial wrapping: for which patient is waistcoat aortoplasty best suited? Interact Cardiovasc Thorac Surg. 2012;14:56–63. doi: 10.1093/icvts/ivr007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Della Corte A, Body SC, Booher AM, Schaefers HJ, Milewski RK, Michelena HI, et al. Surgical treatment of bicuspid aortic valve disease: knowledge gaps and research perspectives. J Thorac Cardiovasc Surg. 2014;147:1749–57. doi: 10.1016/j.jtcvs.2014.01.021. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Fedak PW, Barker AJ, Verma S. Year in review: bicuspid aortopathy. Curr Opin Cardiol. 2016;31:132–8. doi: 10.1097/HCO.0000000000000258. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Hope MD, Hope TA, Crook SE, Ordovas KG, Urbania TH, Alley MT, et al. 4D flow CMR in assessment of valve-related ascending aortic disease. JACC Cardiovasc Imaging. 2011;4:781–7. doi: 10.1016/j.jcmg.2011.05.004. [DOI] [PubMed] [Google Scholar]
  • 42.Hope MD, Wrenn J, Sigovan M, Foster E, Tseng EE, Saloner D. Imaging biomarkers of aortic disease: increased growth rates with eccentric systolic flow. J Am Coll Cardiol. 2012;60:356–7. doi: 10.1016/j.jacc.2012.01.072. [DOI] [PubMed] [Google Scholar]
  • 43.Della Corte A, Bancone C, Conti CA, Votta E, Redaelli A, Del Viscovo L, et al. Restricted cusp motion in right-left type of bicuspid aortic valves: a new risk marker for aortopathy. J Thorac Cardiovasc Surg. 2012;144:360–9. doi: 10.1016/j.jtcvs.2011.10.014. [DOI] [PubMed] [Google Scholar]
  • 44.den Reijer PM, Sallee D, 3rd, van der Velden P, Zaaijer ER, Parks WJ, Ramamurthy S, et al. Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2010;12:4. doi: 10.1186/1532-429X-12-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Garcia J, Barker AJ, Murphy I, Jarvis K, Schnell S, Collins JD, et al. Four-dimensional flow magnetic resonance imaging-based characterization of aortic morphometry and haemodynamics: impact of age, aortic diameter, and valve morphology. Eur Heart J Cardiovasc Imaging. 2016;17:877–84. doi: 10.1093/ehjci/jev228. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

1. Video 1 Three-dimensional Streamline visualization.

Highly eccentric outflow jet pattern was found in the BAV patient in comparison with cohesive streamlines parallel to the vessel wall in the TAV-control patient.

Download video file (1.7MB, mp4)

RESOURCES