Surveillance of surgical site infections by Pseudomonas aeruginosa and strain characterization in Tanzanian hospitals does not provide proof for a role of hospital water plumbing systems in transmission

Nyambura Moremi 1,2,, Heike Claus 1, Ulrich Vogel 1, Stephen E Mshana 2
PMCID: PMC5461769  PMID: 28593044

Abstract

Background

The role of hospital water systems in the development of Pseudomonas aeruginosa (P. aeruginosa) surgical site infections (SSIs) in low-income countries is barely studied. This study characterized P. aeruginosa isolates from patients and water in order to establish possible epidemiological links.

Methods

Between December 2014 and September 2015, rectal and wound swabs, and water samples were collected in the frame of active surveillance for SSIs in the two Tanzanian hospitals. Typing of P. aeruginosa was done by multi-locus sequence typing.

Results

Of 930 enrolled patients, 536 were followed up, of whom 78 (14.6%, 95% CI; 11.6–17.5) developed SSIs. P. aeruginosa was found in eight (14%) of 57 investigated wounds. Of the 43 water sampling points, 29 were positive for P. aeruginosa. However, epidemiological links to wound infections were not confirmed. The P. aeruginosa carriage rate on admission was 0.9% (8/930). Of the 363 patients re-screened upon discharge, four (1.1%) possibly acquired P. aeruginosa during hospitalization. Wound infections of the three of the eight P. aeruginosa SSIs were caused by a strain of the same sequence type (ST) as the one from intestinal carriage. Isolates from patients were more resistant to antibiotics than water isolates.

Conclusions

The P. aeruginosa SSI rate was low. There was no evidence for transmission from tap water. Not all P. aeruginosa SSI were proven to be endogenous, pointing to other routes of transmission.

Keywords: P. aeruginosa, Surgical site infection, Water microbiology, Tanzania

Background

Pseudomonas aeruginosa (P. aeruginosa) has emerged as an important opportunistic pathogen [1]. P. aeruginosa is mostly found in moist environments including hospital water systems [2, 3]. Its ability of forming biofilms contributes to its persistence in water system [4] hence a potential reservoir for Pseudomonas surgical site infections. Wound infections especially caused by multidrug-resistant P. aeruginosa strains are associated with increased morbidity and mortality [5].

Colonization of hospital water plumbing systems with P. aeruginosa has been shown to be an important source of the bacteria facilitating transmission to patients [6, 7]. Other sources such as contamination by P. aeruginosa of healthcare workers’ hands [8] and patient’s P. aeruginosa intestinal carriage [9] have been established to be other potential routes of transmission. The proportion of P. aeruginosa among other bacteria causing wound infections in Tanzania has been reported to be 16.3% (2014) at Muhimbili National Hospital [10] and between 27% (2014) and 40% (2016) at the Bugando Medical Centre (BMC) [11, 12]. In both hospitals, P. aeruginosa was found to contribute significantly to wound infections. Despite the fact that surgical site infections (SSIs) is among global burdens which requires priority [13], routine surveillance as an infection control measure [14] is not done in most low income countries.

In this study we conducted surveillance of SSIs at a Tanzanian regional and a tertiary hospital to assess the burden of SSI and to specifically link P. aeruginosa SSI to asymptomatic carriage and hospital water in order to determine the source.

Methods

Study design and setting

A prospective cohort study was conducted between December 2014 and September 2015 at Sekou Toure and BMC hospitals in the Mwanza region. Sekou Toure is a regional referral hospital with a bed capacity of 300. The BMC is a tertiary referral hospital for 10 out of 30 regions of Tanzania, which has a bed capacity of 1000 and serves about 18 million people. A total of 930 patients who were admitted for surgery (general surgery, obstetrics, gynaecology and orthopaedic) at the two hospitals within the study period were enrolled into the study after signing a written informed consent. Their socio-demographic information and medical history relevant to the study were recorded.

Infection surveillance

Rectal swabs were taken using sterile Amies swabs (Mast Group Ltd., United Kingdom) within 48 h of admission (before surgery), and on discharge to assess P. aeruginosa carriage status. On admission carriage was defined as a positive screening culture within 48 h of being admitted to the hospital in absence of positive clinical specimen [15, 16]. On discharge carriage was defined as a positive screening culture when the patient was discharged from the hospital. Hospital acquired carriage was considered when a strain of P. aeruginosa was not detected upon admission screening or in case of acquisition of a strain of P. aeruginosa with a different sequence type (ST) during hospital stay on discharge.

Patients were followed up by either a surveillance doctor or a trained nurse after surgery to register signs and types of SSI according to NHSN definitions [15]. In case of clinical SSI, a surveillance doctor or a trained nurse took swabs for microbiological investigation. Surveillance doctor’s mobile phone number was given to discharged patients to notify the doctor in case they noted any signs or symptoms of SSI. The total surveillance period was until either a SSI became apparent or up to 30 days after being operated. Patients who underwent orthopaedic surgeries including foreign body implantation were followed-up for 90 days. Text messages were sent to patients every other day to remind them to notify a surveillance doctor when they noted any signs or symptoms of SSI.

Water sampling

Sekou Toure hospital receives its water from a deep drilled well within the hospital compound which is locally chlorinated before being used, whereas BMC hospital receives water from Lake Victoria treated by a modern Capri-point Water Treatment Plant and therefore not locally chlorinated as a routine. The aim of this study was to investigate hospital water used routinely by staff and patients without applying any intervention so as to match recovered P. aeruginosa isolates with patients’ isolates.

Three water taps were identified for cold water sampling as per above explained purposes in each of the 11 wards where patients were enrolled. In addition, operating theatres and main water distribution points were sampled. In total 16 and 27 sampling points were defined in Sekou Toure and BMC hospitals, respectively. Water samples were collected as per DIN EN ISO 19458 (water sampling for microbiological analysis) monthly for up to 10 months in BMC and for four months in Sekou Toure hospital. Water sampling according to purposes A, B, and C was performed as outlined in the international standard EN/ISO 19458:2006 [17] with the aim of assessing the quality of water at the point of delivery to the hospital to rule out contamination from other sources outside hospital premises (purpose A), the quality of the waterlines supplying the taps (purpose B), and the possible contamination of the taps themselves (purpose C). The main difference between purposes A and B is the water volume discarded to flush the disinfectant before sampling, which was 10 L for purpose A and 1.5 L for purpose B. In contrast to purposes A and B, the sampling points were not disinfected for purpose C. A 125 ml-sampling bottle containing sodium thiosulfate (final concentration in the water sample: 20 mg/l) was used. At the Sekou Toure hospital sampling was solely conducted according to purpose C due to the aforementioned nature of water source.

A double-concentrated malachite base (Merck Millipore, Germany) was prepared and when cooled was supplemented with malachite-green oxalate solution (final concentration of 0.02 g/l). Malachite green broth enrichment was used to investigate the presence of P. aeruginosa in water [18], because filtration of water or alternative most probable number approaches required technical equipment not available on site.

Isolation of P. aeruginosa from water

One hundred millilitres of the collected water were inoculated into the 250 ml glass bottles containing 100 ml of malachite-green broth (final concentration of 0.01gmalachite green oxalate /l) and incubated aerobically at 37 °C for 24 to a maximum of 72 h. In case of turbidity and/ or colour changes from green to yellow, 100 μl was sub-cultured onto blood (BD Difco, USA) and cetrimide (Merck Millipore, Germany) agars. The plates were incubated at 37 °C for 24 h. Yellowish-green colonies on cetrimide agar matching the oxidase positive colonies on blood agar were regarded positive for P. aeruginosa. Identification was confirmed by VITEK-MS (bioMérieux, France), because this was the method of choice also for the patient isolates.

Analysis of P. aeruginosa from patients

Sterile cotton swabs (Mast Group Ltd., United Kingdom) were used to collect rectal and pus/wound swab from patients for carriage and infection purposes, respectively. Gram staining and culture of the pus/wound swab was performed in parallel. Pus/wound and rectal swabs were inoculated onto blood and MacConkey agars (BD Difco, USA), respectively, incubated at 37 °C, and examined for growth after 24–48 h. Oxidase test was performed to all non-lactose fermenting colonies. Oxidase-positive colonies were further analysed by VITEK-MS (bioMérieux, France).

All P. aeruginosa isolates were subjected to antimicrobial susceptibility testing using VITEK-2 system (bioMérieux, France) according to the manufacturer’s recommendations. Isolates with intermediate susceptibility were regarded as resistant in the analysis. The recommendations of EUCAST (http://www.eucast.org/clinical_breakpoints/) were applied for evaluation.

Multilocus sequence typing

Multilocus sequence typing (MLST) using seven housekeeping genes was performed as previously described [19]. The PCR products were sequenced at GATC Biotech AG (Cologne, Germany). Sequence alignment and analysis was done using MegAlign software (DNASTAR Inc. USA) and the P. aeruginosa MLST website http://pubmlst.org/paeruginosa/was used to assign isolates to their respective sequence types (STs).

Carbapenemase gene screening

All four P. aeruginosa isolates with either intermediate or resistant susceptibility to carbapenems were screened for metallo-beta lactamase genes (bla IMP, bla VIM [20], bla GIM, bla NDM, bla SIM, bla SPM and bla OXA-48) [21]as described previously.

Data analysis

Data were analysed using STATA version 13 (STATA Corp LP, USA). Categorical variables were summarized as proportions and were analysed using the Pearson’s Chi-Square test or Fisher’s exact to test statistical differences among the various groups. The two-sample test of proportion was used to calculate 95% confidence interval (CI) and the Mann Whitney ranksum test was performed to compare medians. A p-value of less than 0.05 was considered statistically significant.

Results

Demographics

A total of 930 patients (57.8% female) were enrolled. The BMC tertiary hospital contributed to 64.9% (n = 604). The median age of the participants was 32.1 (range 2 months-83 years). Most patients came from Mwanza (61.9%, n = 576), Mara (10.1%, n = 94) and Shinyanga (8.5%, n = 79) regions. Of the 930 patients screened for P. aeruginosa carriage on admission, 363 were re-screened on discharge. After discharge follow-up was restricted to patients with mobile phones, therefore, 57.6% (536/930) of the enrolled patients were successfully followed-up. The median age (years) of followed-up patients was 26 (IQR: 18–42) while for those not followed-up was 31 (IQR: 23–48), p = 0.0001. Other socio-demographic parameters (sex, hospital, marital status, occupation etc) were equally distributed within the two groups.

SSI rates, types and P. aeruginosa carriage

Of the 536 patients followed-up after discharge, 78 (14.6%, 95% CI; 11.6–17.5) developed SSI. The wounds of 57 patients were investigated microbiologically, of which 50 (87.7%) had significant bacterial growth and eight (14%) were positive for P. aeruginosa. All patients with P. aeruginosa SSI were classified as superficial incisional SSI (A1).

Of the 930 patients screened on admission, eight (0.9%) were found to be colonized with P. aeruginosa as demonstrated by rectal swabs. Of the 363 patients re-screened on discharge, seven (1.9%) were colonized with P. aeruginosa. Of those, four possibly acquired the strain during hospitalization and the remaining three patients were colonized upon admission and discharge.

P. aeruginosa In the water distribution

Cold water samples were taken from taps located in wards as well as in the operating theatres. The mean (±standard deviation) water temperature was 26.2 (±0.4) and 25.8 (±0.8)°C at BMC and Sekou Toure hospitals, respectively. Twenty-two (81.5%) of the 27 water sampling points from BMC hospital were positive for P. aeruginosa throughout the study period; 11 (40.7%) were positive for P. aeruginosa at least twice (Table 1). At BMC hospital, sampling points were positive in the months December 2014 (N = 11), and January (N = 6), August (N = 6) and September (N = 15) 2015, resulting in 38 P. aeruginosa isolates. Seven (44%) of the 16 sampling points from Sekou Toure hospital were positive throughout the study period; only one sampling point was positive more than once resulting in ten isolates (Table 2).

Table 1.

Sequence type distribution among Pseudomonas aeruginosa detected at 22 out of 27 sampling points at Bugando Medical Centre hospital

Sampling point Ward/ sampling point category Sampling plan Number of P. aeruginosa recovery from water taps in 10 months Sequency type of P. aeruginosa
1 Main distribution - A 2 of 10 381, 2320a
2 OT changing room Operating Theatre B 2 of 10 381
3 OT2 Operating Theatre C 3 of 10 381, 252, 2307a
4 OT3 Operating Theatre C 1 of 10 381
5 OT5 Operating Theatre C 1 of 10 381
6 OT sluice Operating Theatre C 1 of 10 381
7 LWOT Maternity Operating Theatre B 1 of 10 381
8 LW staff WC Maternity C 1 of 10 381
9 LW patient WC Maternity C 2 of 10 381, 834
10 C4 patient WC Maternity C 2 of 10 381, 641
11 C4 sluice Maternity C 1 of 10 2327a
12 E4 patient WC Gynaecology C 2 of 10 381, 2307a
13 E4 sluice Gynaecology C 1 of 10 2325a
14 J5 staff WC Orthopaedic B 4 of 10 381, 834, 2307a
15 J5 patient WC Orthopaedic C 1 of 10 2326a
16 C6 staff WC General surgery B 3 of 10 381, 834
17 C6 patient WC General surgery C 1 of 10 381
18 E8 Staff WC Orthopaedic B 1 of 10 381
19 E8 patient WC Orthopaedic C 3 of 10 381
20 C9 staff WC General surgery B 2 of 10 381
21 C9 patient WC General surgery C 1 of 10 381
22 C9 sluice General surgery C 2 of 10 381, 236

Key: WC: Water Closet (Toilet); aNew ST; bold letters indicate common clone

Table 2.

Sequence type distribution among Pseudomonas aeruginosa detected at seven out of 16 total sampling points at Sekou Toure hospital

Sampling point Ward/ sampling point category Sampling plan Number of P. aeruginosarecovery from water taps in 4 months Sequency type of P. aeruginosa
1 Main distribution - C 1 of 4 2307*
2 STGN station Gynaecology C 4 of 4 2307*
3 FW station Female C 1 of 4 252
4 MW2 patient WC Male C 1 of 4 316
5 LW station Maternity C 1 of 4 2307*
6 OT1 Operating theatre C 1 of 4 2307*
7 OT2 Operating theatre C 1 of 4 2307*

Key: WC: Water Closet (Toilet); aNew ST; bold letters indicate common clone

Sequence types distribution

A total of 18 different sequence types (STs) was observed among 71 P. aeruginosa isolates of which eight were new STs. Ten STs occurred only once (Table 3). Of the eight patients with P. aeruginosa SSI, four from the BMC hospital harboured the multi-resistant ST235. Two of the four patients with SSI due to P. aeruginosa ST235 were treated in the same ward and developed SSI two days apart. Three patients with SSI harboured strains bearing the same STs as those in their intestines i.e. STs 235, 2309 and 2319 (Table 4). Three patients carried P. aeruginosa isolates that shared STs with isolates recovered from water taps of the wards they were admitted in (Table 4). As shown in Table 3, the overlap of STs of strains from patients and the water distribution was minimal, only STs 2307 and 252 were observed in both hospitals. ST2307 and ST381 were observed in 66.7% (8/12) and in 42.4% (25/59) of isolates from Sekou Toure and BMC hospital, respectively.

Table 3.

Sequence type distribution among Pseudomonas aeruginosa isolates from Sekou Toure and Bugando Medical Centre hospitals

Sequence type Sekou Toure hospital
(N = 12)
BugandoMedical Centre hospital (N = 59)
Patients (2) Water(10) Patients (21) Water (38)
2307a - 8 4 3
2309a 2 - - -
2317a - - 1 -
2319a - - 4 -
2320a - - - 1
2325a - - - 1
2326a - - - 1
2327a - - - 1
235 - - 6 -
236 - - - 1
244 - - 1 -
252 - 1 - 1
316 - 1 - -
381 - - 1 25
399 - - 3 -
553 - - 1 -
641 - - - 1
834 - - - 3

Key: aNew ST; bold letters indicate sequence type identity shared by patients and water samples

Table 4.

Possible transmission sources among 17 patients who carried and/or were infected with Pseudomonas aeruginosa

Patient
ID
Age (years) Sex Hospital Ward Category Type of Surgery Hospital stay
(days)
P.a. Carriage at Admission P.a. strain (ST) P.a. Carriage at Discharge P. a. strain (ST) SSI with P. a. P. a. strain (ST) P. a. strain (ST) in admitting ward
70 55 M Bugando General surgery Laparotomy 7 Yes 2319a No - No - 381, 834
93 67 M Bugando General surgery Esophagotomy 2 Yes 2319 a Yes 2319 a Yes 2319 a 381, 834
528 26 M Bugando General surgery Laparotomy 18 No - No - Yes 2317a 381, 834
532 27 M Bugando General surgery Colostomy 6 No - Yes 553 No - 381, 834
323 1 F Bugando General surgery Fistulectomy 8 No - Yes 399 No - 381, 236
436 47 M Bugando General surgery Mastectomy 2 Yes 399 Yes 399 No - 381, 236
477 63 F Bugando General surgery Mastectomy 2 Yes 381 No - No - 381, 236
GN001 58 F Bugando Gynaecology Laparotomy 10 Yes 2307 a Yes 2307 a No - 381, 2307 a, 2325a
GN002 49 F Bugando Gynaecology Myomectomy 10 No - Yes 2307 a No - 381, 2307 a, 2325a
GN003 45 F Bugando Gynaecology Laparotomy 4 Yes 2307 a No - No - 381, 2307, a 2325a
GN026 33 F Bugando Gynaecology Laparotomy 8 No - No - Yes 244 381, 2307a, 2325a
33 27 M Bugando Orthopaedic ORIF 23 No - No - Yes 235 381
41 28 M Bugando Orthopaedic ORIF 21 No - No - Yes 235 381
245 83 M Bugando Orthopaedic ORIF 10 Yes 235 No - No - 381
11 54 F Bugando Orthopaedic ORIF 33 No - No - Yes 235 381, 834, 2307a, 2326a
LW028 31 F Bugando Obstetrics Csection 3 Yes 235 No - Yes 235 381, 834
ST098 30 F Sekou Toure Obstetrics Csection 4 No - Yes 2309* Yes 2309 a 2307a

Key: P.a; Pseudomonas aeruginosa; SSI; Surgical site infection; ORIF; Open Reduction Internal Fixation; Csection; Caesarean Section; aNew sequence type (ST); bold numbers indicate shared sequence type identity between carried and SSI P. aeruginosa or between carried P. aeruginosa and P. aeruginosa from water samples in the same ward. All 17 patients were followed-up for SSI

Antimicrobial susceptibility

Fifty-six P. aeruginosa isolates were analysed of which 17 were non-repetitive isolates from patients and 39 from water. Only one strain per sequence type (ST) per patient and one strain per ST per sampling point were included in this analysis. All clinical and water isolates were resistant to aztreonam (Table 5). Of patients’ isolates, 41.2% (7/17), 35.3% (6/17) and 17.7% (3/17) were resistant to piperacillin-tazobactam, ceftazidime and meropenem/imipenem, respectively. Higher resistance rates were observed in patients in comparison to water isolates for piperacillin-tazobactam (p = 0.001), ceftazidime (p < 0.001) and amikacin (p = 0.0004). Fosfomycin resistance was significantly more frequent in water isolates than in clinical isolates (61.5% vs. 17.7%, p = 0.001) (Table 5).

Table 5.

Resistance rates of Pseudomonas aeruginosa isolates from patients and water

Antimicrobial agent Patients isolates (17) Water isolates (39) P value
N (%) N (%)
Amikacin 5 (29.4) 0 (0) 0.0004
Aztreonam 17 (100) 39 (100) -
Cefepime 1 (5.9) 0 (0) 0.063
Ceftazidime 6 (35.3) 0 (0) <0.001
Ciprofloxacin 5 (29.4) 6 (15.4) 0.112
Colistin 0 (0) 0 (0) -
Ertapenem 3 (17.7) 1 (2.6) 0.0256
Fosfomycin 3 (17.7) 24 (61.5) 0.001
Gentamicin 5 (29.4) 5 (12.8) 0.06
Imipinem 3 (17.7) 1 (2.6) 0.0219
Meropenem 3 (17.7) 0 (0) 0.0035
Piperacillin 8 (47.1) 7 (18.0) 0.012
Piperacillin-tazobactam 7 (41.2) 1 (2.6) 0.001
Tobramycin 5 (29.4) 2 (5.1) 0.005

All four isolates with reduced susceptibility to carbapenems were screened for carbapenemase genes, of which none of them tested positive.

Discussion

In this study the rate of P. aeruginosa SSI was low and accounted for a minor proportion of all SSIs. One reason for this might be the low intestinal carriage rate on admission imposing a low risk of endogenous infection [9]. Despite the low number of patients with P. aeruginosa SSI, this study confirmed intestinal carriage as a source of infection in three patients based on MLST typing. As explained previously [22], personal hygiene has been found to contribute to endogenous transmission. This is further supported in the current study by the fact that the three patients with an evidence of endogenous source developed infection after being discharged from the hospital; explaining the possibility of poor hygiene at home during the change of dressing.

In the current study the difference of P. aeruginosa carriage rates upon admission and discharge was not statistically significant. The relative low rate observed on the discharge could be explained by the low yield of a single-time swabbing compared to multiple swabbing [9]. However, as documented previously [23] regarding hospital acquisition of P. aeruginosa, four patients who were negative on admission were found to be colonized upon discharge, indicating possible hospital acquisition of P. aeruginosa.

Out of eight patients with P. aeruginosa SSI, four were found to belong to ST235, a multi-resistant clone, which is widely distributed in European [24, 25] and Asian countries [26, 27]. Unlike previous reports on this international high-risk clone [25, 28, 29], carbapenemase genes such as bla VIM-2 were not identified by PCR. Interestingly, two of the four patients with P. aeruginosa ST235 SSI were spatio-temporally linked; pointing to the possibility of a common source in the ward.

Although more than 80% of the sampled water taps at BMC hospital were at least once positive for P. aeruginosa during the observation period, no clear linkage to P. aeruginosa SSI was established in contrast to what has been reported previously [6]. This observation could be explained by the fact that, the taps were found to be P. aeruginosa free amidst the surveillance period following the intervention such as local chlorination made by the BMC hospital infection control team after seeing preliminary sampling results. This could have affected the link of P. aeruginosa SSI to water system because during the intervention period patients were at risk of getting P. aeruginosa SSI but the exogenous risk (water system colonization) was absent.

Another reason might be the possibility of low bacterial loads. Due to the technique employed in this study, only the presence of P. aeruginosa was detected, but not the quantity. Although the current study could not establish the association between water system and P. aeruginosa SSI, two sequence types (ST381 and ST2307) were shared between patient’s carriage and water system; underscoring the possible role of water system in cross-transmission of Pseudomonas [30]. Despite established evidence that P. aeruginosa contamination of wastewater systems such as toilets and shower sinks [31] might also serve as sources of infection, wastewater systems were not analysed for P. aeruginosa in this study.

Conclusions

To the best of our knowledge this is one of the largest studies on the prevalence of P. aeruginosa induced SSI in Africa. Post-discharge surveillance was effective due to the use of text message recalls. Although the rate of P. aeruginosa SSI was low, endogenous sources appeared to be a more probable source of transmission than the hospital water system. Multi-resistance of P. aeruginosa to clinically used antibiotics is an issue which needs to be taken into account.

Acknowledgements

The authors thank the technical assistance provided by Vitus Silago and Hezron Basu of the CUHAS microbiology laboratory. They are grateful to the key surveillance nurses from BMC hospital (Stella Rujwauka, Grace Ludovick, Maulidi Misanga, Tecla Tumsime and Paul Mvanda) as well as for nurses from SekouToure hospital (Pili Mbwana Kombo, Flora George Masanja and Anna Paul Lwanji), for their participation in this study.

Funding

This study was supported by funds from the Institute for Hygiene and Microbiology of Wuerzburg, Germany, CUHAS and German Academic Exchange Service (DAAD) to NM.

This publication was funded by the German Research Foundation (DFG) and the University of Wuerzburg in the funding programme Open Access Publishing.

Availability of data and materials

All data have been included in this manuscript.

Authors’ contributions

NM, HC, UV and SEM conceived the idea and designed the study. NM collected data. NM performed preliminary laboratory analysis. NM and HC performed molecular characterization of the isolates. HC, SEM, UVand NM analysed data. NM wrote the first draft of the manuscript which was reviewed and approved by UV, HC and SEM. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

The Joint CUHAS/BMC research ethics and review committee approved the study protocol with clearance number CREC/019/2014. All patients signed an informed written consent.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Abbreviations

BMC

Bugando Medical Centre

DIN

Deutsches Institut für Normung (German Institute for Standardization)

EN

European Committee for Standardization

EUCAST

European Committee on Antimicrobial Susceptibility Testing

ISO

International Organization for Standardization

MLST

Multilocus sequence typing

NHSN

National Healthcare Safety Network

SSI

surgical site infection

ST

Sequence type

Contributor Information

Nyambura Moremi, Email: nyambura.moremi@stud-mail.uni-wuerzburg.de, Email: nyamburasogone@gmail.com.

Heike Claus, Email: hclaus@hygiene.uni-wuerzburg.de.

Ulrich Vogel, Email: vogel_u@ukw.de.

Stephen E. Mshana, Email: mshana72@yahoo.com

References

  • 1.Bodey GP, Bolivar R, Fainstein V, Jadeja L. Infections caused by Pseudomonas aeruginosa. Rev Infect Dis. 1983;5:2. doi: 10.1093/clinids/5.Supplement_1.S2. [DOI] [PubMed] [Google Scholar]
  • 2.Bert F, Maubec E, Bruneau B, Berry P, Lambert-Zechovsky N. Multi-resistant Pseudomonas aeruginosa outbreak associated with contaminated tap water in a neurosurgery intensive care unit. J Hosp Infect. 1998;39:1. doi: 10.1016/S0195-6701(98)90243-2. [DOI] [PubMed] [Google Scholar]
  • 3.Ferroni A, Nguyen L, Pron B, Quesne G, Brusset M, Berche P: Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination. J Hosp Infect 1998;39:4. [DOI] [PubMed]
  • 4.Falkinham JO, III, Hilborn ED, Arduino MJ, Pruden A, Edwards MA. Epidemiology and ecology of opportunistic premise plumbing pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. Environ Health Perspect. 2015;123:8. doi: 10.1289/ehp.1408692. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Turner KH, Everett J, Trivedi U, Rumbaugh KP, Whiteley M. Requirements for Pseudomonas aeruginosa acute burn and chronic surgical wound infection. PLoS Genet. 2014;10:7. doi: 10.1371/journal.pgen.1004518. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Loveday H, Wilson J, Kerr K, Pitchers R, Walker J, Browne J. Association between healthcare water systems and Pseudomonas aeruginosa infections: a rapid systematic review. J Hosp Infect. 2014;86:1. doi: 10.1016/S0195-6701(13)60012-2. [DOI] [PubMed] [Google Scholar]
  • 7.Garvey MI, Bradley CW, Tracey J, Oppenheim B. Continued transmission of Pseudomonas aeruginosa from a wash hand basin tap in a critical care unit. J Hosp Infect. 2016;94:1. doi: 10.1016/j.jhin.2016.07.001. [DOI] [PubMed] [Google Scholar]
  • 8.Agodi A, Barchitta M, Cipresso R, Giaquinta L, Romeo MA, Denaro C. Pseudomonas aeruginosa carriage, colonization, and infection in ICU patients. Intensive Care Med. 2007;33:7. doi: 10.1007/s00134-007-0671-6. [DOI] [PubMed] [Google Scholar]
  • 9.Thuong M, Arvaniti K, Ruimy R, De la Salmoniere P, Scanvic-Hameg A, Lucet J, et al. Epidemiology of Pseudomonas aeruginosa and risk factors for carriage acquisition in an intensive care unit. J Hosp Infect. 2003;53:4. doi: 10.1053/jhin.2002.1370. [DOI] [PubMed] [Google Scholar]
  • 10.Manyahi J, Matee MI, Majigo M, Moyo S, Mshana SE, Lyamuya EF. Predominance of multi-drug resistant bacterial pathogens causing surgical site infections in Muhimbili national hospital, Tanzania. BMC Res Notes. 2014;7:1. doi: 10.1186/1756-0500-7-500. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Moremi N, Mushi MF, Fidelis M, Chalya P, Mirambo M, Mshana SE. Predominance of multi-resistant gram-negative bacteria colonizing chronic lower limb ulcers (CLLUs) at Bugando medical center. BMC Res Notes. 2014;7:1. doi: 10.1186/1756-0500-7-211. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Nobert N, Moremi N, Seni J, Dass RM, Ngayomela IH, Mshana SE, et al. The effect of early versus delayed surgical debridement on the outcome of open long bone fractures at Bugando medical Centre, Mwanza, Tanzania. J Trauma Manag Outcomes. 2016;10:1. doi: 10.1186/s13032-016-0036-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Abbas M, Pittet D. Surgical site infection prevention: a global priority. J Hosp Infect. 2016;93:4. doi: 10.1016/j.jhin.2016.06.002. [DOI] [PubMed] [Google Scholar]
  • 14.Allegranzi B, Bischoff P, de Jonge S, Kubilay NZ, Zayed B, Gomes SM, et al. New WHO recommendations on preoperative measures for surgical site infection prevention: an evidence-based global perspective. Lancet Infect Dis. 2016;16:12. doi: 10.1016/S1473-3099(16)30398-X. [DOI] [PubMed] [Google Scholar]
  • 15.Horan TC, Andrus M, Dudeck MA. CDC/NHSN surveillance definition of health care–associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control. 2008;36:5. doi: 10.1016/j.ajic.2008.03.002. [DOI] [PubMed] [Google Scholar]
  • 16.Bertrand X, Thouverez M, Talon D, Boillot A, Capellier G, Floriot C, et al. Endemicity, molecular diversity and colonisation routes of Pseudomonas aeruginosa in intensive care units. Intensive Care Med. 2001;27:8. doi: 10.1007/s001340100979. [DOI] [PubMed] [Google Scholar]
  • 17.DIN E. 19458: water quality- sampling for microbiological analysis ISO 19458. 2006. [Google Scholar]
  • 18.Habs H, Kirschner K. Der Pyocyaneus-Meerschweinchenhautversuch zur Prüfung von Hautdesinfektionsmitteln. Med Microbiol Immunol. 1942;124:5. [Google Scholar]
  • 19.Curran B, Jonas D, Grundmann H, Pitt T, Dowson CG. Development of a multilocus sequence typing scheme for the opportunistic pathogen Pseudomonas aeruginosa. J Clin Microbiol. 2004;42:12. doi: 10.1128/JCM.42.12.5644-5649.2004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Pitout JD, Gregson DB, Poirel L, McClure J-A, Le P, Church DL. Detection of Pseudomonas aeruginosa-producing metallo-β-lactamases in a large centralized laboratory. J Clin Microbiol. 2005;43:7. doi: 10.1128/JCM.43.7.3129-3135.2005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Poirel L, Walsh TR, Cuvillier V, Nordmann P. Multiplex PCR for detection of acquired carbapenemase genes. Diagn Microbiol Infect Dis. 2011;70:1. doi: 10.1016/j.diagmicrobio.2010.12.002. [DOI] [PubMed] [Google Scholar]
  • 22.Kagan LJ, Aiello AE, Larson E. The role of the home environment in the transmission of infectious diseases. J Community Health. 2002;27:4. doi: 10.1023/A:1016378226861. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Murthy SK, Baltch AL, Smith R, Desjardin E, Hammer M, Conroy J, et al. Oropharyngeal and fecal carriage of Pseudomonas aeruginosa in hospital patients. J Clin Microbiol. 1989;27:1. doi: 10.1128/jcm.27.1.35-40.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Glupczynski Y, Bogaerts P, Deplano A, Berhin C, Huang T-D, Van Eldere J, et al. Detection and characterization of class a extended-spectrum-β-lactamase-producing Pseudomonas aeruginosa isolates in Belgian hospitals. J Antimicrob Chemother. 2010;65:5. doi: 10.1093/jac/dkq048. [DOI] [PubMed] [Google Scholar]
  • 25.Edelstein MV, Skleenova EN, Shevchenko OV, D'souza JW, Tapalski DV, Azizov IS, et al. Spread of extensively resistant VIM-2-positive ST235 Pseudomonas aeruginosa in Belarus, Kazakhstan, and Russia: a longitudinal epidemiological and clinical study. Lancet Infect Dis. 2013;13:10. doi: 10.1016/S1473-3099(13)70168-3. [DOI] [PubMed] [Google Scholar]
  • 26.Yoo JS, Yang JW, Kim HM, Byeon J, Kim HS, Yoo JI, et al. Dissemination of genetically related IMP-6-producing multidrug-resistant Pseudomonas aeruginosa ST235 in South Korea. Int J Antimicrob Agents. 2012;39:4. doi: 10.1016/j.ijantimicag.2011.11.018. [DOI] [PubMed] [Google Scholar]
  • 27.Kim MJ, Bae IK, Jeong SH, Kim SH, Song JH, Choi JY, et al. Dissemination of metallo-β-lactamase-producing Pseudomonas aeruginosa of sequence type 235 in Asian countries. J Antimicrob Chemother. 2013;68:12. doi: 10.1093/jac/dks373. [DOI] [PubMed] [Google Scholar]
  • 28.Libisch B, Watine J, Balogh B, Gacs M, Muzslay M, Szabó G, et al. Molecular typing indicates an important role for two international clonal complexes in dissemination of VIM-producing Pseudomonas aeruginosa clinical isolates in Hungary. Res Microbiol. 2008;159:3. doi: 10.1016/j.resmic.2007.12.008. [DOI] [PubMed] [Google Scholar]
  • 29.Correa A, Del Campo R, Perenguez M, Blanco VM, Rodríguez-Baños M, Perez F, et al. Dissemination of high-risk clones of extensively drug-resistant Pseudomonas aeruginosa in Colombia. Antimicrob Agents Chemother. 2015;59:4. doi: 10.1128/AAC.03926-14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Rogues A-M, Boulestreau H, Lashéras A, Boyer A, Gruson D, Merle C, et al. Contribution of tap water to patient colonisation with Pseudomonas aeruginosa in a medical intensive care unit. J Hosp Infect. 2007;67:1. doi: 10.1016/j.jhin.2007.06.019. [DOI] [PubMed] [Google Scholar]
  • 31.Breathnach A, Cubbon M, Karunaharan R, Pope C, Planche T. Multidrug-resistant Pseudomonas aeruginosa outbreaks in two hospitals: association with contaminated hospital waste-water systems. J Hosp Infect. 2012;82:1. doi: 10.1016/j.jhin.2012.06.007. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

All data have been included in this manuscript.


Articles from Antimicrobial Resistance and Infection Control are provided here courtesy of BMC

RESOURCES