Abstract
Monoclonal antibodies to Toxoplasma gondii were used in an enzyme-linked immunosorbent assay to detect antigens of the parasite in toxoplasma lysate, in peritoneal fluid of mice, and in sera from humans acutely infected with T. gondii. Four of the six monoclonal antibodies were able to detect antigens of toxoplasma in these specimens. Control sera from individuals not infected with T. gondii and from individuals chronically infected with the parasite were negative in the enzyme-linked immunosorbent assay. Sera from individuals not infected with T. gondii but with positive titers from rheumatoid factor were also negative; 2 or 10 sera from individuals not infected with T. gondii but with positive titers for antinuclear antibodies reacted with the monoclonal antibodies. When the results of the enzyme-linked immunosorbent assay with monoclonal antibodies and with the F(ab)2 fraction of an immunoglobulin G from a rabbit infected with T. gondii were compared, it was noted that the F(ab)2 was more active in detecting parasite antigens than were the monoclonal antibodies. Thus, although monoclonal antibodies can be used to detect antigens of T. gondii in sera and other body fluids, polyvalent antibody (such as the F(ab)2 fraction) appears to be more satisfactory for this purpose.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Araujo F. G., Barnett E. V., Gentry L. O., Remington J. S. False-positive anti-Toxoplasma fluorescent-antibody tests in patients with antinuclear antibodies. Appl Microbiol. 1971 Sep;22(3):270–275. doi: 10.1128/am.22.3.270-275.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Araujo F. G., Remington J. S. Antigenemia in recently acquired acute toxoplasmosis. J Infect Dis. 1980 Feb;141(2):144–150. doi: 10.1093/infdis/141.2.144. [DOI] [PubMed] [Google Scholar]
- Goding J. W. Conjugation of antibodies with fluorochromes: modifications to the standard methods. J Immunol Methods. 1976;13(3-4):215–226. doi: 10.1016/0022-1759(76)90068-5. [DOI] [PubMed] [Google Scholar]
- Handman E., Goding J. W., Remington J. S. Detection and characterization of membrane antigens of Toxoplasma gondii. J Immunol. 1980 Jun;124(6):2578–2583. [PubMed] [Google Scholar]
- Köhler G., Milstein C. Continuous cultures of fused cells secreting antibody of predefined specificity. Nature. 1975 Aug 7;256(5517):495–497. doi: 10.1038/256495a0. [DOI] [PubMed] [Google Scholar]
- Rekvig O. P., Hannestad K. The specificity of human autoantibodies that react with both cell nuclei and plasma membranes: the nuclear antigen is present on core mononucleosomes. J Immunol. 1979 Dec;123(6):2673–2681. [PubMed] [Google Scholar]
- Rubin R. L., Carr R. I. Anti-DNA activity of IgG F(ab')2 from normal human serum. J Immunol. 1979 Apr;122(4):1604–1607. [PubMed] [Google Scholar]
- Warren R. C., Bartlett A., Bidwell D. E., Richardson M. D., Voller A., White L. O. Diagnosis of invasive candidosis by enzyme immunoassay of serum antigen. Br Med J. 1977 May 7;1(6070):1183–1185. doi: 10.1136/bmj.1.6070.1183. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wolters G., Kuijpers L., Kacaki J., Schuurs A. Solid-phase enzyme-immunoassay for detection of hepatitis B surface antigen. J Clin Pathol. 1976 Oct;29(10):873–879. doi: 10.1136/jcp.29.10.873. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yolken R. H., Stopa P. J. Analysis of nonspecific reactions in enzyme-linked immunosorbent assay testing for human rotavirus. J Clin Microbiol. 1979 Nov;10(5):703–707. doi: 10.1128/jcm.10.5.703-707.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
