Dear Editor,
I am Dr. Hung-Yuan Lin, from the Universal Eye Center, Taiwan, China. I write to present one of the crucial techniques that enables easy maneuverability for ophthalmologists who perform the conventional method, which requires a corneal incision of 2.75-3.0 mm in width shifted to microincision phacoemulsification that only requires a corneal incision of 1.8-2.2 mm in width.
In 2014 APACRS survey and trends, we noted there are nearly 40% of cataract surgery with 2.8 mm clear corneal incision (CCI)[1]. Learning to achieve an adequate capsulorhexis following a shift in surgical techniques from conventional coaxial phacoemulsification to coaxial microincision cataract surgery (C-MICS) can be challenging, especially when attempting to create a quality circular continuous curvilinear capsulorhexis (CCC) through a smaller incision using standard capsulorhexis forceps. Some surgeons have performed CCC in larger corneal wounds by moving the capsulorhexis forceps in a parallel direction (Figure 1). Consequently, when the size of the CCI is reduced, it becomes difficult to achieve a well centered and amply sized CCC due to the tight fit of the capsulorhexis forceps inside the main incision. Further, the decreased size of the incision reduces maneuverability and places local stress on the wound, which distorts the corneal surface and reduces visualization.
Figure 1. Movement of surgical instruments, including capsulorhexis forceps, in a parallel direction such that it pushes on any edge of the incision; the actions can cause extensive corneal deformation, coupled with striae, which impairs the surgical view.

Many microincision capsulorhexis forceps have been designed to accommodate smaller incisions and the subsequently reduced access size for achieving an adequate capsulorhexis. But a learning curve always exists when using different types of forceps and that will increase risk factors for occurrence of intra-operative complications during phacoemulsification performed by inexperience surgeon. Herein, we would like to share our experience that employs the same standard straight-shank capsulorhexis forceps (Figure 2) used for single instrument capsulorhexis procedures with different CCI widths (Figure 3).
Figure 2. Standard straight-shank capsulorhexis forceps used for single instrument capsulorhexis procedure.

Figure 3. Standard straight-shank capsulorhexis forceps used for single instrument 1.8-mm capsulorhexis procedure.

We intend to introduce the pivot concept, that require any surgical instruments used for phacoemulsification, including standard capsulorhexis forceps, to be centered on a fixed pivot point within the CCI to allow for a wide range of movement (Figure 4). When performing the CCC, the forceps shaft is supported between the thumb and the middle finger and the forefinger rests on the top of the shaft with keep the wrist steady and make small movements of the fingers to move the forceps tip in different direction to create curved line, both hands move together and where one hand stabilizes and the other manipulates (Figure 5). The hand of operator holding the instrument must move toward the right to shift the tip of the instrument toward the left (Figure 5). Similarly, to move the instrument downward, the back end of the instrument must be shifted upward. Further, with a fixed pivot point large movements outside the cornea produce only limited movement inside the eye[2]. Another key point for accomplishing a consistent sized capsulorhexis is that after a curving tear is directed radially to the desired diameter of the CCC, the flap must be grasped with the capsulorhexis forceps, and the traction applied tangentially in the desired direction. Thus, the curvature angle must be larger (Figure 6) to achieve a similar capsular opening (5.0-5.5 mm) when the corneal incision wound becomes smaller.
Figure 4. Surgical instruments used for phacoemulsification are centered on a fixed pivot point within the CCI to allow for a wide range of movement.

Figure 5. Hand of the operator holding the instrument must move toward the left such that the tip of the instrument shifts toward the right and vice versa.

Figure 6. The curvature angle must be larger to achieve a similar capsular opening (5.0-5.5 mm) when the corneal incision wound becomes smaller (2.2, 1.8, 1.6 mm).

The recent developments in cataract surgery have focused on reducing the incision size[3]. Many studies have determined that larger incisions cause increase surgically induced astigmatism (SIA). The SIA was approximately 0.50 D in the 3.0 mm and almost zero to 0.25 D in incisions of 2.2 mm or less[4]. When considering the future of customized surgery, which could accommodate and allow adjustments for personal corneal aberrations, incisions less than 2.0 mm in size will be essential, and could enable the performance of surgery without degrading corneal optical quality[5].
Phacoemulsification with CCI ranging between 1.8-2.8 mm was performed on our patients using different phacoemulsification devices. In our practice, we did not need to prepare a different type of capsulorhexis forceps for the distinct size of the CCI, which enabled the entire surgical procedure to proceed smoothly, and saved time during the pre-surgical preparation of instruments. Further, achieving proficiency does not require any change to our technique, and the use of standard capsulorhexis forceps to create a good quality CCC through a clear corneal wound less than 2.0 mm in size can be continued.
In fact, pivot concept has demonstrated excellent intraocular instrument maneuverability using not only standard capsulorhexis forceps, but also the phacoemulsification probe, and the irrigation/aspiration tips. Because the elasticity of the corneal is limited, irreversible expansion of the incision and potential tissue lacerations may occur with a smaller incision. When a surgeon uses instruments forcefully to push on any edge of the incision, the actions can cause extensive corneal deformation, coupled with striae, which impairs the surgical view, and causes mechanical corneal trauma[6]. Further, the ultrasonic energy from the phacoemulsification probe can produce a significant amount of heat, which can burn the cornea within seconds, and induce corneal thermal burn injuries[7]. Clinical implications of wound trauma include difficulty in wound sealing, Descemet's membrane tears, or endothelial damage that causes corneal edema, or prolonged healing.
Even though similar ideas or principal has been proposed in the past, however, no publications of similar relevance can be found in current nor past literatures. Therefore, our hope is to share such findings with fellow residents in guiding them with future surgical techniques.
To conclude, our experience showed that a very simple alternative approach decreases the incidence of capsule complications reliably even in challenging cases. Adapting the pivot concept in all cataract surgeries enables the surgeon to make the successful performance of a much safer surgical procedure in patients.
Acknowledgments
Presented in part at the XXXII Congress of the European Society of Cataract & Refractive Surgeons, London, UK, September 2014.
The authors wish to thank Dr. Abhay Vasavada for many helpful comments of the manuscript.
Conflicts of Interest: Lin HY, None; Chuang YJ, None; Tang X, None; Lin CC, None; Chen HY, None; Lin PJ, None.
REFERENCES
- 1.2014 APACRS survey results and trends
- 2.Devgan U. Surgeons should master pivoting, maneuvering within the eye. Ocular Surgery News. 2012.
- 3.Klamann MK, Gonnermann J, Maier AK, Torun N, Bertelmann E. Smaller incision size leads to higher predictability in microcoaxial cataract surgery. Eur J Ophthalmol. 2013;23(2):202–207. doi: 10.5301/ejo.5000207. [DOI] [PubMed] [Google Scholar]
- 4.Dewey S, Beiko G, Braga-Mele R, Nixon DR, Raviv T, Rosenthal K. ASCRS Cataract Clinical Committee, Instrumentation and IOLs Subcommittee. Microincisions in cataract surgery. J Cataract Refract Surg. 2014;40(9):1549–1557. doi: 10.1016/j.jcrs.2014.07.006. [DOI] [PubMed] [Google Scholar]
- 5.Denoyer A, Ricaud X, Van Went C, Labbé A, Baudouin C. Influence of corneal biomechanical properties on surgically induced astigmatism in cataract surgery. J Cataract Refract Surg. 2013;39(8):1204–1210. doi: 10.1016/j.jcrs.2013.02.052. [DOI] [PubMed] [Google Scholar]
- 6.Weikert MP, Wang L, Barrish J, Dimalanta R, Koch DD. Quantitative measurement of wound architecture in microincision cataract surgery. J Cataract Refract Surg. 2012;38(8):1460–1466. doi: 10.1016/j.jcrs.2012.03.036. [DOI] [PubMed] [Google Scholar]
- 7.Sippel KC, Pineda R., Jr Phacoemulsification and thermal wound injury. Semin Ophthalmol. 2002;17(3-4):102–109. doi: 10.1076/soph.17.3.102.14776. [DOI] [PubMed] [Google Scholar]
