Abstract
Background
Whilst significant progress has been made in the fight against malaria, vector control continues to rely on just two insecticidal methods, i.e., indoor residual spraying and insecticidal bed nets. House improvement shows great potential to complement these methods and may further reduce indoor mosquito biting and disease transmission. Open eaves serve as important mosquito house entry points and provide a suitable location for intercepting host-seeking anophelines. This study describes semi-field experiments in western Kenya with eave tubes, a household protection product that leverages the natural behaviour of host-seeking malaria mosquitoes.
Methods
Semi-field experiments were conducted in two screen-houses. In both of these a typical western Kenyan house, with mud walls and corrugated iron sheet roofing, was built. Eave tubes with bendiocarb- or deltamethrin-treated eave tube inserts were installed in the houses, and the impact on house entry of local strains of Anopheles gambiae and Anopheles arabiensis was determined. Experiments with open eave tubes (no netting) were conducted as a control and to determine house entry through eave tubes. Insecticidal activity of the inserts treated with insecticide was examined using standard 3-min exposure bioassays.
Results
Experiments with open eave tubes showed that a high percentage of released mosquitoes entered the house through tubes during experimental nights. When tubes were fitted with bendiocarb- or deltamethrin-treated inserts, on average 21% [95% CI 18–25%] and 39% [CI 26–51%] of An. gambiae s.s. were recaptured the following morning, respectively. This contrasts with 71% [CI 60–81%] in the treatment with open eaves and 54% [CI 47–61%] in the treatment where inserts were treated with fluorescent dye powder. For An. arabiensis recapture was 21% [CI 14–27%] and 22% [CI 18–25%], respectively, compared to 46% [CI 40–52%] and 25% [CI 15–35%] in the treatments with open tubes and fluorescent dye.
Conclusions
Insecticide-treated eave tubes resulted in significant reductions in recapture rates for both malaria vector species, representing the first and promising results with this novel control tool against Kenyan malaria vectors. Further field evaluation of eave tubes under more realistic field conditions, as well as their comparison with existing approaches in terms of cost-effectiveness and community acceptance, is called for.
Electronic supplementary material
The online version of this article (doi:10.1186/s12936-017-1926-5) contains supplementary material, which is available to authorized users.
Keywords: Eave tubes, Semi-field system, House improvement, Kenya, Anopheles gambiae, Anopheles arabiensis
Background
The last decade has seen major successes in the global fight against malaria. Long lasting insecticidal nets (LLINs) and indoor residual spraying (IRS), combined with improved diagnosis and effective medication, have saved millions of lives [1]. Nevertheless, despite the impressive progress made in malaria control, the disease remains a substantial global public health problem, with 429,000 deaths (92% of these in Africa) and 212 million cases (90% of these in Africa) in 2015, affecting mostly children and pregnant women [2]. Furthermore, the large-scale use of a limited arsenal of World Health Organization (WHO)-recommended public health insecticides, and impact from agricultural pesticide residues in the environment [3, 4] have resulted in the development of widespread insecticide resistance in mosquitoes [5, 6].
For sustainable vector control the development of new tools and insecticides that successfully target disease-transmitting mosquitoes remains a top priority [7, 8].
House improvements have shown great potential to reduce mosquito biting and decrease the risk for house occupants to contract malaria [9–11]. Since the major African malaria vectors are predominantly endophagic and nocturnal, up to 80–100% of infectious bites occur indoors [12]. Preventing house entry of host-seeking mosquitoes can, therefore, be an effective means to reduce malaria transmission. This was, for instance, demonstrated in a large trial in The Gambia where both fully screened houses or the use of screened ceilings yielded an impressive 50% reduction in anaemia in children under 10 years of age compared to children occupying unscreened housing [13].
Across Africa, traditional house designs are rapidly being replaced with more modern structures. Houses with mud walls and grass-thatched roofs transition to more durable domiciles consisting of concrete or brick walls and corrugated iron sheet roofs [11, 14, 26]. These changes in house design offer new opportunities to interfere with mosquito host-seeking behaviour. An important entry route for Anopheles mosquitoes into houses is through the ventilation opening between the wall and the roof, the so-called ‘eave’ [15–18]. Convection heat causes human odour-laden air inside the house to rise. This airstream is funnelled outwards through the eaves at night, which causes attraction of host-seeking mosquitoes. The importance of eaves as the preferred entry point for Anopheles mosquitoes, and therefore as a suitable site to intercept these at this stage, has been recognized by WHO since 1997 [19].
House modifications aimed at reducing indoor biting, such as insecticide-treated eave curtains, have shown entomological [20] as well as epidemiological impact [21]. Furthermore, field studies have demonstrated that, compared to houses with open eaves, inhabitants of houses with closed eaves experienced significantly fewer bites indoors and had a lower risk of malaria infection [16, 22–24]. A trial with permethrin-treated eave curtains (in which the entire eave gap was closed with netting material and doors and windows were screened) in Burkina Faso showed a 15% reduction in child mortality [25]. There is good evidence and justification, therefore, to focus on eaves as a point to interrupt the life cycle of anophelines and in doing so prevent malaria transmission.
In the present study the eave tube concept that targets malaria mosquitoes at eave level was evaluated. The basic principle of the eave tube concept is to limit mosquito access to the house by screening or blocking openings where feasible and adding tubes fitted with removable gauze inserts [26, 27]. Installation of eave tubes starts by rendering houses mosquito proof through sealing of the eaves and screening the windows and subsequently introducing openings in the wall at eave level, which leverage the natural route of host-seeking mosquitoes to enter houses at night through open eaves. When mosquitoes enter an eave tube they encounter a netting barrier, consisting of an insert fitted with insecticide-treated electrostatic netting. Previous research has shown that this electrostatic netting can bind a variety of insecticides and provides enhanced bioavailability of these insecticides [28, 29]. A major benefit of eave tubes is that they work passively, not requiring active engagement from house occupants, as is the case with LLINs, which require daily involvement when in use. Installed beyond the reach of house occupants they enable safe use of insecticides, including the use of actives that are not (yet) recommended for IRS or LLINs, which opens options for using alternative insecticides and biopesticides such as the entomopathogenic fungus Beauveria bassiana, which may be effective against pyrethroid-resistant populations. Here, it is shown how electrostatic netting, when used inside eave tubes provides a novel delivery tool for insecticidal agents to target malaria vectors.
This study evaluated the use of eave tubes in an experimental semi-field setting in Kenya, where prototype tubes and inserts were fitted into a replicate of a local mud-walled house with corrugated iron roofing sheets. The impact of insecticide-treated eave tube inserts was evaluated through assessment of exposure rates and mortality impact using two species of Kenyan anophelines. House entry of mosquitoes through open eave tubes (without netting) was recorded to assess responses of mosquitoes towards tubes as house entry points.
Methods
Experimental set-up
The study was carried out at the International Centre of Insect Physiology and Ecology (ICIPE) located at Mbita Point, western Kenya (0°26′06.19″S, 34°12′53.13″E). Two semi-field screen-houses, both 7.1 × 11 m in size, were used in parallel. Screen-houses, i.e. large outdoor enclosures covered with netting, were designed to simulate a natural ecosystem for anopheline mosquitoes, as previously described by Knols et al. [30], had sandy soil, little vegetation, and mosquito resting places that consisted of moist clay pots [31]. In each of the screen-houses an experimental house of 3 × 3 m was constructed and fitted with a single bed in which a volunteer slept under an untreated bed net during experimental nights (Fig. 1a, b). The houses resembled a local rural design with walls made out of mud and a roof made out of corrugated iron sheets as is commonly seen in western Kenya. A mixture of wood, ash and clay was used for plastering and smoothing the wall surfaces. Openings and cracks in the walls were sealed with clay and the window was fitted with untreated mosquito-proof netting and a cotton curtain. In each hut the eaves were sealed and a total of six black 6-in. PVC pipes were installed at 1-min intervals under the roof at eave height in each house (Fig. 1c).
Eave tube prototypes
As the concept of eave tubes for malaria vector control progressed, alternative designs with varying features and characteristics were developed and tested (Fig. 2a–l). Following experimentation on tube size in Tanzania [27, and Fig. 2b therein], eave tube inserts were designed to fit in 6-in. PVC pipes, which are widely available across Africa. The inserts used in this study were 45 mm high and conically shaped, with a diameter of 144 mm at the bottom end and 156 mm at the top end (Fig. 2l). Because the polypropylene is flexible, the inserts fit in PVC pipes of variable thickness, without allowing space for mosquitoes to pass. The spokes in the insert provide additional support to enable handling, stacking (Fig. 2k) and placement of the insert in tubes. In this study, black 20 cm long, PVC pipes were used. The inserts were placed halfway into the tubes (Fig. 2j) to prevent direct exposure to sunlight. A video that shows how an insert is being installed inside a PVC pipe is shown in Additional file 1.
Mosquitoes
Experiments were conducted with Anopheles gambiae s.s. and Anopheles arabiensis mosquitoes that were colonized from specimens that originated from the Mbita area. Larvae were reared in filtered water from Lake Victoria and fed twice a day on locally available cat food. Pupae were collected daily and placed into 30 × 30 × 30 cm netting cages until emergence. Adults were offered ad libitum access to a 6% glucose solution and were fed on blood from adult human volunteers that were examined twice a week for the presence of malaria parasites. Mosquitoes were reared under ambient climatic conditions in a screen-house similar to the ones in which experiments were conducted. Prior to the experiments, host-seeking female mosquitoes were selected from adult holding cages and placed in cylindrical release cups.
Eave tube treatment
Eave tube inserts were fitted with netting with an electrostatic coating that binds insecticidal particles [28]. Because the electrostatic coating enables adherence of particles without a carrier or impregnation process, a large variety of active compounds can be used. Here, orange fluorescent dust (BVDA International BV, Haarlem, The Netherlands) and two insecticides widely used in malaria vector control, i.e., bendiocarb (Ficam D, 1.25% a.i., Bayer, Leverkusen, Germany) and deltamethrin (Spritex 0.25% a.i., Denka International BV, Barneveld, The Netherlands) were used. Fluorescent or insecticide powder formulations were applied on electrostatic netting by placing the inserts in a closed bucket with an excess amount of formulation and shaking it for 15–30 s until the inserts were saturated.
Exposure bioassays
Exposure bioassays were conducted before the experiments according to WHO protocol [32] and were similar to the MCD bottle assay described by Sternberg et al. [33]. Insecticidal activity of the inserts saturated with insecticide was checked using 3-min exposure assays with 50 host-seeking female mosquitoes, exposed in cohorts of five to ten individuals. Knockdown (1 h post exposure) and mortality rates (24 h post exposure) were recorded. Bioassays were conducted with fluorescent dust (control treatment) or bendiocarb/deltamethrin dust applied onto the electrostatic netting. Baseline exposure doses were measured by determining the presence and amount of fluorescent particles on the exposed mosquito bodies, by killing the females after exposure and checking them using a UV light microscope (Dino Lite Premier). A second series of exposures was performed at the end of the semi-field trials with the inserts that had been used for three to five consecutive weeks in order to ascertain that the residual activity of the insecticides remained unchanged throughout the experimental period.
Results from the semi-field bioassays indicated that temperature could have an impact on insecticidal impact on mosquitoes. To examine the influence of temperature on survival following bendiocarb or deltamethrin exposure, non-blood fed, 5-day-old An. gambiae females were exposed to these insecticides at 18 or 27 °C using the MCD bottle bioassay at Penn State University. Mosquitoes were from a single cohort that had been reared to adults at a constant 27 °C. Females were moved to environmental chambers set to 18 or 27 °C and 85% RH 15–30 min prior to exposure. For each of five replicates, five mosquitoes were aspirated into an MCD bottle fitted with either untreated electrostatic netting, or netting treated with the same bendiocarb or deltamethrin formulations as used in Kenya. A glass bottle filled with hot water served as an attractant source and exposures lasted 1 min. Once removed from the MCD bottle, mosquitoes were kept at treatment temperature for 24 h. Mortality was assessed after 24 h; mosquitoes that were moribund or unable to fly were scored as dead.
Screen-house experiments
The two mosquito species were tested in succession, the first 3 weeks (6 replicates) focused on An. gambiae s.s. and the following 5 weeks (13 replicates) on An. arabiensis. Larger variation in control treatment recaptures for An. arabiensis necessitated more replicates. For each species, fresh tube inserts with actives were prepared and installed at the start of the experimental series. Before each experimental night, eave tube inserts were placed inside the tubes in the experimental houses, after which 200 host-seeking female mosquitoes were released outside the houses at 19.00 h local time. A sleeper was present inside the house under an untreated bed net to serve as bait for the host-seeking mosquitoes. Two rounds of collections were done the following morning at 07.00 h and at 12:00 h according to normal practice at the research site when conducting screenhouse experiments. One technician per screenhouse collected mosquitoes for 1 h both inside and outside the houses using a backpack aspirator and recorded the numbers recaptured. After each experiment the inserts were removed from the houses and stored at ambient temperature in the laboratory. These inserts were (re-) used six times over a period of approximately 3 weeks.
Two different methods were used to determine house entry through eave tubes: (a) open eave tubes (PVC only without installing the eave tube inserts); and, (b) eave tube inserts treated with fluorescent dye that served as a proxy for contact with insecticidal netting during the experimental night [see 29 and Fig. 5 therein]. During experiments with open tubes, mosquitoes could freely enter the house and the number that entered the house was determined through indoor collections using both a standard CDC miniature light trap (John W Hock Co., USA) positioned next to the bed net [34] and a backpack aspirator. Attraction of eave tubes was assessed by treating the netting with fluorescent powder, a non-lethal marker [35] to measure the proportion of females released that contacted the netting installed in the eave tube. Mosquitoes bearing fluorescent dye were scored using a UV light microscope (Dino Lite Premier, USA).
The experiments reported here differ from those reported from semi-field studies in Tanzania [27] in three ways. First, unlike the experimental (wooden) huts that were used in Tanzania, the work in Kenya was conducted in copies of real housing structures found in western Kenya that consisted of mud walls and corrugated iron sheet roofing. Second, eave tubes in Tanzania were covered with (treated) netting, whereas the Kenya studies used inserts that can be mass-produced (Fig. 2l). Finally, the Kenya study differed in that it not only incorporated another (Kenyan) strain of An. arabiensis but also, for the first time, a local strain of An. gambiae s.s.
Climate data
To measure exposure conditions, climate data from data loggers (VOLTCRAFT DL-121TH, Conrad Electronic Benelux BV, Oldenzaal, The Netherlands) placed inside and outside the experimental houses was recorded. Both data loggers were suspended 0.5 m below the edge of the ceiling and temperature and humidity were recorded during experimental hours at 30-min intervals.
Data analysis
Raw data was collected on daily record sheets and entered into an Excel spreadsheet the following day. Data was available to all involved in the research via an online platform. Impact of the insecticides was calculated by comparing the numbers of retrieved mosquitoes for the different treatments and the controls. Differences in recapture numbers served as an indicator for the potential vector control impact of eave tubes achieved within a single night [27].
Data were analysed using SPSS 21.0 software. Normality of the data was investigated using the Shapiro–Wilk test and homogeneity of variances was tested with Levene’s Test (untransformed data). Treatments were compared using the Mann–Whitney U test with Bonferroni correction for multiple comparisons.
R software (version 3.2.1; the R Foundation for statistical computing, Austria) was used to analyse the effect of temperature on insecticide-induced mortality. Fixed effects were insecticide exposure (control or bendiocarb/deltamethrin), temperature (18 or 27 °C) and the interaction between these parameters.
Results
Exposure bioassays
At the onset of the experimental series, exposure bioassays with both bendiocarb and deltamethrin yielded 100% knockdown (1 h) and 100% mortality (24 h) for both mosquito species (four replicates in total; Table 1). Fluorescent dust was used as a control treatment and exposure to inserts treated with fluorescent dye resulted in mortality lower than 20% in all bioassays (Table 1). In all replicates 100% of mosquitoes were contaminated with fluorescent dust, confirming that the bioassay method was effective for exposing mosquitoes in the screenhouse experiments.
Table 1.
Before screen-house tests | After screen-house tests | ||||
---|---|---|---|---|---|
Species | Eave tube insert treatment | Knockdown average % [±95% CI] | Mortality average % [±95% CI] | Knockdown average % [±95% CI] | Mortality average % [±95% CI] |
An. gambiae | Fluorescent dust | 6.5 [2.4–10.6] | 17.8 [7.3–28.4 ± 5.4] | 0 | 4.1 [0.9 to 7.2] |
Deltamethrin (0.25%) | 100 | 100 | 100 | 100 | |
Bendiocarb (1.25%) | 100 | 100 | 98.9 [96.9–101.1] | 98.9 [96.9 to 101.1] | |
An. arabiensis | Fluorescent dust | 0 | 1.0 [−0.1 to 2.2] | 0 | 1.8 [−1.7 to 5.3] |
Deltamethrin (0.25%) | 100 | 100 | 98.5 [96.9–100.4] | 96.6 [93.2 to 99.9] | |
Bendiocarb (1.25%) | 100 | 100 | 33.4 [9.7–57.2] | 38.8 [11.2 to 66.3] |
After extensive handling of the inserts during the screen-house experiments, deltamethrin and bendiocarb-treated inserts still resulted in 99–100% An. gambiae s.s. mortality in the exposure assays. For An. arabiensis the efficacy of bendiocarb-treated inserts reduced sharply after the screen-house experiments, resulting in only 33% knockdown and 39% mortality.
Interestingly, there was a clear effect of temperature on the efficacy of bendiocarb on An. gambiae females exposed using the MCD bottle. While deltamethrin killed 100% of exposed mosquitoes regardless of temperature, bendiocarb gave on average a 60% lower mortality (Χ2 = 20.8, df1,19, p < 0.001) at 18 than at 27 °C (Fig. 3).
Response to eave tubes
Experiments with open eave tubes (i.e., PVC pipes only without eave tube inserts to prevent house entry) were conducted to measure responses of both species towards eave tubes as house entry points. For the series with An. gambiae s.s, an average of 71% [95% CI 60–81%] of the mosquitoes released each night were recaptured. Of these, 92% were caught indoors, out of which 31% was recaptured with the CDC light trap and 61% with the backpack aspirator. For An. arabiensis, overall recapture was lower at 46% [CI 40–52%], of which 76% was recaptured indoors (Fig. 4).
CDC light trap catches were smaller than expected and comprised less than half of the total mosquito numbers retrieved. Use of this recapture technique alone would have caused an underestimation of the number of mosquitoes that entered the house, which is why backpack aspiration was included.
The second method to determine mosquito responses to eave tubes was based on colour marking of mosquitoes with fluorescent dye when making contact with tube netting [29]. Following an experimental night, mosquitoes were recaptured, killed and examined for the presence of fluorescent dust using a UV light microscope. On average 41% [CI 32–51%] of the recaptured An. gambiae s.s. mosquitoes had fluorescent dust on their bodies, indicating that they had contact (at least once) with the fluorescent-dust-treated inserts. For An. arabiensis this was 30% [CI 21–40%].
Insecticide treatments
Results showed a significant impact on mosquito mortality when eave tube inserts were treated with insecticide. Out of 200 An. gambiae s.s. mosquitoes released each night, significantly fewer were recaptured the following morning when deltamethrin-treated inserts were used, compared to the control treatments (with open eave tubes; p = 0.002, Mann–Whitney U test, Bonferroni corrected; Table 2) and the control treatment with fluorescent dye (p = 0.002). No significant difference was found for inserts treated with bendiocarb compared to the fluorescent dust treatment. After an experimental night with deltamethrin-treated inserts, on average 21% [CI 14–29%] of the released mosquitoes was recaptured compared to 71% [CI 60–81%] in the control treatment with open eave tubes; for bendiocarb-treated inserts this was 39% [CI 26–51%].
Table 2.
Species | Treatment | % | [95% CI] | # released | # recaptured | p values | |
---|---|---|---|---|---|---|---|
An. gambiae | Open | 70.8 | [60.3–81.4] | 1200 | 850 | – | 0.041 |
FD | 54.1 | [47.3–60.8] | 1200 | 649 | 0.041 | – | |
BC | 38.8 | [26.2–51.3] | 1200 | 465 | 0.009 | 0.065 | |
DM | 21.3 | [14.0–28.7] | 1200 | 256 | 0.002 | 0.002 | |
An. arabiensis | Open | 45.8 | [39.7–51.8] | 2600 | 1190 | – | 0.020 |
FD | 25.2 | [14.9–35.4] | 2600 | 654 | 0.020 | – | |
BC | 20.6 | [14.4–26.9] | 2600 | 536 | <0.001 | 0.762 | |
DM | 22.0 | [18.1–25.0] | 2600 | 572 | <0.001 | 0.614 |
Treatments included two controls; open eave tubes (Open) or inserts with fluorescent dye (FD). Controls were compared to treatments with bendiocarb (BC) or deltamethrin (DM)-treated inserts using Mann–Whitney U tests
Results for An. arabiensis (Table 2) were similar, although the impact of the insecticide treatments was smaller. After an experimental night with deltamethrin-treated inserts, on average 22% [CI 18–25%] of the released mosquitoes was recaptured compared to 46% [CI 40–52%] in the control treatment with open eave tubes; for bendiocarb-treated inserts this was 25% [CI 15–35%]. Insecticide treatments were significantly different from the control with open eave tubes (p < 0.001) but not different from the control with fluorescent powder. Raw data on the recapture of An. gambiae and An. arabiensis during experimental nights with either control or insecticide treatments is provided in Additional file 2.
Climate data
Both temperature and humidity (Fig. 5) were, on average, higher inside the experimental houses compared to outside. Average temperature inside was 2.8 °C higher, for relative humidity there was a 17.7% difference. A small but significant, on average 0.8 °C, increase in temperature inside the house was observed after placing eave tube inserts in the pipes, compared to open pipes (p < 0.001, Mann–Whitney U test); no significant difference was found for relative humidity.
Discussion
Here, the first evaluation of eave tube technology under semi-field conditions against Kenyan strains of insecticide-susceptible An. gambiae s.s. and An. arabiensis (Mbita strains) is presented. It was shown that houses commonly found in western Kenya, constructed out of mud walls with corrugated iron sheet roofing, are highly suitable for this approach. Both species responded strongly to host odours emanating from the tubes as was noted by the high number of mosquitoes recaptured indoors when the tubes were left open, as well as the considerable number that contacted the inserts treated with fluorescent dust. Interestingly, the response of An. gambiae s.s. to eave tubes was considerably higher than that of An. arabiensis, which may be explained by the generally more endophilic and endophagic nature of the former species [36]. Noteworthy is also the fact that the response of both strains decreased when the tubes were closed with inserts. It is likely that the reduced airflow through the inserts may be a cause for this reduction. Since the netting in the inserts used was quite dense (air permeability of 1600 L/sq m/sec at 20 Pa; ISO 9237:1995) and airflow attenuation can already be considerable with the more open mesh sizes used in commercial LLINs [37], an improvement of tube attraction with more open mesh sizes is foreseen. This reduced airflow also affected indoor climate, which made the house slightly warmer (ca. 0.8 °C) during the night, as well as slightly more humid (ca. 1.3% RH). The more pronounced difference in humidity between the indoor and outdoor environment may be explained by the fact that the houses had only recently been constructed in the screen-houses so that the walls were giving off substantial amounts of water vapour present in the mud during the building stage. Alternatively, or in addition, the presence of a human host in this relatively small house may have caused an increase in indoor humidity through exhaled air. Overall, the differences in indoor climate caused by the installation of eave tubes was minimal and similar to observations from Tanzania (data not published).
Two insecticides commonly used in vector control, deltamethrin and bendiocarb, were applied in powder formulation on the electrostatic netting of the eave tube inserts and tested in the PVC pipes. Both treatments resulted in significant reductions in the number of retrieved mosquitoes compared to the control treatment with open eave tubes; albeit less so when compared with the dye treatments. These findings are in line with the results obtained in screen-house studies in Tanzania [27]. Given the large proportion of mosquitoes around a house that can be targeted with eave tubes, it is foreseen that with substantial coverage and in combination with LLINs they can have a big impact on mosquito populations and hence on malaria transmission [38].
The impact of bendiocarb on mosquito mortality when exposed at different temperatures gives rise to concern regarding the validity of insecticide-resistance assays being performed under a range of insectary and field temperatures. It is also surprising that this phenomenon was not apparent for the pyrethroid insecticide but more so for the carbamate. In essence, this calls for the evaluation of insecticidal impact under different temperature regimes and standardization of climate conditions under which exposure bioassays occur.
Mosquitoes were effectively blocked from the house after the windows were screened with untreated netting and treated eave tube inserts were fitted in the PVC pipes. The doors of the experimental houses were always kept closed during the experiments, and it can be argued that this may not always be so under realistic field conditions. However, even though doors that are kept open during dusk and the night will allow entry by mosquitoes, these belong mostly to the nuisance biting culicines and few will transmit malaria [15, 16, 31]. During the day the house heats up, creating upward convection currents at night that carry body odours upward towards the eaves. Thus, even when the doors are open(ed) and windows are not or only partially screened, the majority of malaria mosquitoes will still enter through the eaves and use it as their primary entry point into the house. This was confirmed by field data from the Kilombero valley in Tanzania, where >90% reduction in indoor mosquito numbers was achieved after houses were rendered mosquito proof and eave tubes were installed [27].
The total surface area of treated eave tube insert netting is very small and only a fraction of the surface sprayed during IRS or even the total surface of an LLIN, which means that much less insecticide will be needed. This will have an impact on cost, and it was estimated that eave tubes are roughly half the cost of IRS (Knols et al., in prep.). Moreover, the >95% reduction in the amount of insecticide needed per house will have major implications on operational costs, particularly when cheaper pyrethroids are being replaced by the more expensive carbamates (bendiocarb) or organophosphates (e.g., pirimiphos-methyl). Ultimately, this can greatly reduce the impact of insecticide costs on control campaigns, which for IRS at present is estimated at 24% [39].
An additional benefit of eave tube technology is that it provides protection for everyone residing indoors. This protection will be longer and more pronounced than bed nets that only protect sleepers during the hours of active use. Moreover, bed net occupants will have daily exposure to pyrethroids when occupying the net, which is overcome when eave tubes are used that are beyond the reach of house occupants. Eave tubes therefore provide a safe means for using insecticides in the vicinity of humans with minimal exposure risk, which opens up possibilities to use actives that would not normally be recommended for wall spraying or bed net impregnation. In turn, this will open opportunities to manage insecticide resistance through the development of inserts that hold more than one active, or use of inserts in houses with different treatments, so that the vector population is constantly exposed to a variety of insecticides [40]. The eave tube design that was used in this study was recently taken into mass production. Further optimizations and development of treatment, washing and re-treatment production systems provide opportunities for development of a product that can be cost-competitive, user-friendly and has impact on malaria vectors comparable to or better than existing vector control tools, notably IRS. This may include the development and production of eave tube inserts out of biodegradable plastics or even re-cycled LLINs.
Besides an effect on malaria vectors, eave tube technology will also provide options to reduce indoor densities of nuisance mosquitoes and exposure to other disease vectors. It was previously found that screening house-entry points also has an effect on indoor densities of vectors of neglected tropical diseases (NTDs), such as lymphatic filariasis, dengue, leishmaniasis [41, 42] and even trachoma and fly-transmitted diarrhoeal disease. This means that eave tubes could contribute to an integrated vector control programme aimed at reducing multiple vector-transmitted diseases [43]. Overall, the technology responds to a dire need for additional measures beyond LLINs and IRS to further the goals of malaria eradication and control of NTDs.
Deployment of LLINs has previously been shown to induce community-wide effects when coverage is high, thereby reducing malaria transmission even in houses that remain unprotected [18, 25]. This advocates for the implementation of mosquito-killing agents, rather than only improving houses with untreated physical barriers. As with LLINs and IRS, eave tubes (in combination with window/door screening) are expected to induce community-wide effects, whereby houses that are unsuitable for eave tube installation still benefit from the technology. Determining what level of coverage is necessary to reduce transmission overall will help inform implementation strategies [38, 44].
Conclusions
The proposed introduction of eave tube technology (i.e. closing of eaves, installation of eave tubes, and rendering houses mosquito-proof through window/door screening) for malaria control in Africa [26] has so far been supported with encouraging data from semi-field studies in Tanzania [27], which are corroborated with the outcomes of the present semi-field study with Kenyan strains of An. gambiae s.s. and An. arabiensis. Given the large numbers of females of both strains that were attracted to the eave tubes when responding to host odours emanating from the house, it is likely that similar responses may occur under natural field conditions and hence large numbers of female mosquitoes can be killed by insecticide. There is a need to maintain caution, as this work represents semi-field studies with strains of mosquitoes that have been kept under artificial conditions for several years. Confirmation of these findings in open field studies is therefore required, as well as provision of epidemiological, social and economic evidence that the approach can impact on malaria under real-life conditions [44]. Direct observations on the behaviour of wild mosquitoes inside eave tubes in village houses will be a follow-up article in this series.
Additional files
Authors’ contributions
JS, BNN, BG, and PO built the study system and conducted the experiments. AJO designed and developed the inserts. KG performed the MCD bottle assays at PSU. BGJK, JM and MF designed the experiments and revised the manuscript. JS and BNN analysed data and JS, RA, BGJK, KG, and MF wrote the manuscript. All authors read and approved the submitted manuscript.
Acknowledgements
We thank David Alila for providing mosquitoes for this study and Kennedy Omolo and Martin Kirindo for their technical support. This work was supported by European Union Seventh Framework Programme Grant 306105, FP7-HEALTH-2012-INNOVATION-1.
Competing interests
AJO, MF and BGJK hold shares in In2Care BV. In2Care BV has one or more patents or patent applications related to the subject of this paper.
Funding
This work was part of the Mosquito Contamination Device (MCD) project (http://www.mcdproject.org) that was supported by European Union Seventh Framework Programme Grant 306105, FP7-HEALTH-2012-INNOVATION-1.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abbreviations
- RH
relative humidity
- IRS
indoor residual spraying
- LLIN
long-lasting insecticide-treated bed net
- MCD
mosquito contamination device
- MDG
Millennium Development Goal
- NTD
neglected tropical diseases
- WHO
World Health Organization
Footnotes
Electronic supplementary material
The online version of this article (doi:10.1186/s12936-017-1926-5) contains supplementary material, which is available to authorized users.
Contributor Information
Janneke Snetselaar, Email: janneke.snetselaar@lshtm.ac.uk.
Basilio N. Njiru, Email: basiliongari@gmail.com
Beatrice Gachie, Email: beatricegachie@yahoo.com.
Phillip Owigo, Email: owigop@yahoo.com.
Rob Andriessen, Email: robandriessen@hotmail.com.
Katey Glunt, Email: kdglunt@gmail.com.
Anne J. Osinga, Email: anne@in2care.org
James Mutunga, Email: jmutunga@icipe.org.
Marit Farenhorst, Email: marit@in2care.org.
Bart G. J. Knols, Email: b.knols@science.ru.nl
References
- 1.Bhatt S, Weiss DJ, Cameron E, Bisanzio D, Mappin B, Dalrymple U, et al. The effect of malaria control on Plasmodium falciparum in Africa between 2000 and 2015. Nature. 2015;526:207–211. doi: 10.1038/nature15535. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.WHO. World Malaria Report 2016. Geneva: World Health Organization; 2016.
- 3.Diabate A, Baldet T, Chandre F, Akogbeto M, Guiguemde TR, Darriet F, et al. The role of agricultural use of insecticides in resistance to pyrethroids in Anopheles gambiae s.l. in Burkina Faso. Am J Trop Med Hyg. 2002;67:617–622. doi: 10.4269/ajtmh.2002.67.617. [DOI] [PubMed] [Google Scholar]
- 4.Nauen R. Insecticide resistance in disease vectors of public health importance. Pest Manag Sci. 2007;63:628–633. doi: 10.1002/ps.1406. [DOI] [PubMed] [Google Scholar]
- 5.Hemingway J, Ranson H. Insecticide resistance in insect vectors of human disease. Annu Rev Entomol. 2000;45:371–391. doi: 10.1146/annurev.ento.45.1.371. [DOI] [PubMed] [Google Scholar]
- 6.Hemingway J. The role of vector control in stopping the transmission of malaria: threats and opportunities. Philos Trans R Soc Lond B Biol Sci. 2014;369:20130431. doi: 10.1098/rstb.2013.0431. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Hemingway J, Beaty BJ, Rowland M, Scott TW, Sharp BL. The innovative vector control consortium: improved control of mosquito-borne diseases. Trends Parasitol. 2006;22:308–312. doi: 10.1016/j.pt.2006.05.003. [DOI] [PubMed] [Google Scholar]
- 8.malERA Consultative Group on Vector Control A research agenda for malaria eradication: vector control. PLoS Med. 2011;8:e1000401. doi: 10.1371/journal.pmed.1000401. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Lindsay SW, Emerson PM, Charlwood JD. Reducing malaria by mosquito-proofing houses. Trends Parasitol. 2002;18:510–514. doi: 10.1016/S1471-4922(02)02382-6. [DOI] [PubMed] [Google Scholar]
- 10.Anderson L, Simpson D, Stephens M. Durable housing improvements to fight malaria transmission: can we learn new strategies from past experience? Atlanta: Habitat for Humanity International Global Programs Department; 2014. [Google Scholar]
- 11.Tusting LS, Ippolito MM, Willey BA, Kleinschmidt I, Dorsey G, Gosling RD, et al. The evidence for improving housing to reduce malaria: a systematic review and meta-analysis. Malar J. 2015;14:209. doi: 10.1186/s12936-015-0724-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Huho B, Briet O, Seyoum A, Sikaala C, Bayoh N, Gimnig J, et al. Consistently high estimates for the proportion of human exposure to malaria vector populations occurring indoors in rural Africa. Int J Epidemiol. 2013;42:235–247. doi: 10.1093/ije/dys214. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Kirby MJ, Ameh D, Bottomley C, Green C, Jawara M, Milligan PJ, et al. Effect of two different house screening interventions on exposure to malaria vectors and on anaemia in children in The Gambia: a randomised controlled trial. Lancet. 2009;374:998–1009. doi: 10.1016/S0140-6736(09)60871-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Liu JX, Bousema T, Zelman B, Gesase S, Hashim R, Maxwell C, et al. Is housing quality associated with malaria incidence among young children and mosquito vector numbers? Evidence from Korogwe, Tanzania. PLoS ONE. 2014;9:e87358. doi: 10.1371/journal.pone.0087358. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Njie M, Dilger E, Lindsay SW, Kirby MJ. Importance of eaves to house entry by anopheline, but not culicine, mosquitoes. J Med Entomol. 2009;46:505–510. doi: 10.1603/033.046.0314. [DOI] [PubMed] [Google Scholar]
- 16.Lwetoijera DW, Kiware SS, Mageni ZD, Dongus S, Harris C, Devine GJ, et al. A need for better housing to further reduce indoor malaria transmission in areas with high bed net coverage. Parasit Vectors. 2013;6:57. doi: 10.1186/1756-3305-6-57. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Wanzirah H, Tusting LS, Arinaitwe E, Katureebe A, Maxwell K, Rek J, et al. Mind the gap: house structure and the risk of malaria in Uganda. PLoS ONE. 2015;10:e0117396. doi: 10.1371/journal.pone.0117396. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Lindsay SW, Snow RW. The trouble with eaves; house entry by vectors of malaria. Trans R Soc Trop Med Hyg. 1988;82:645–646. doi: 10.1016/0035-9203(88)90546-9. [DOI] [PubMed] [Google Scholar]
- 19.Roozendaal JA. Vector control: methods for use by individuals and communities. Geneva: World Health Organization; 1997. [Google Scholar]
- 20.Cuzin-Ouattara N, Van den Broek AH, Habluetzel A, Diabate A, Sanogo-Ilboudo E, Diallo DA, et al. Wide-scale installation of insecticide-treated curtains confers high levels of protection against malaria transmission in a hyperendemic area of Burkina Faso. Trans R Soc Trop Med Hyg. 1999;93:473–479. doi: 10.1016/S0035-9203(99)90343-7. [DOI] [PubMed] [Google Scholar]
- 21.Habluetzel A, Diallo DA, Esposito F, Lamizana L, Pagnoni F, Lengeler C, et al. Do insecticide-treated curtains reduce all-cause child mortality in Burkina Faso? Trop Med Int Health. 1997;2:855–862. doi: 10.1046/j.1365-3156.1997.d01-413.x. [DOI] [PubMed] [Google Scholar]
- 22.Bradley J, Rehman AM, Schwabe C, Vargas D, Monti F, Ela C, et al. Reduced prevalence of malaria infection in children living in houses with window screening or closed eaves on Bioko Island, equatorial Guinea. PLoS ONE. 2013;8:e80626. doi: 10.1371/journal.pone.0080626. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Atieli H, Menya D, Githeko A, Scott T. House design modifications reduce indoor resting malaria vector densities in rice irrigation scheme area in western Kenya. Malar J. 2009;8:108. doi: 10.1186/1475-2875-8-108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Animut A, Balkew M, Lindtjorn B. Impact of housing condition on indoor-biting and indoor-resting Anopheles arabiensis density in a highland area, central Ethiopia. Malar J. 2013;12:393. doi: 10.1186/1475-2875-12-393. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Lengeler C. Insecticide-treated bed nets and curtains for preventing malaria. Cochrane Database Syst Rev. 2002;2:CD000363. doi: 10.1002/14651858.CD000363.pub2. [DOI] [PubMed] [Google Scholar]
- 26.Knols BGJ, Farenhorst M, Andriessen R, Snetselaar J, Suer RA, Osinga AJ, et al. Eave tubes for malaria control in Africa: an introduction. Malar J. 2016;15:404. doi: 10.1186/s12936-016-1452-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Sternberg ED, Ng’habi KR, Lyimo IN, Kessy ST, Farenhorst M, Thomas MB, et al. Eave tubes for malaria control in Africa: initial development and semi-field evaluations in Tanzania. Malar J. 2016;15:447. doi: 10.1186/s12936-016-1499-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Andriessen R, Snetselaar J, Suer RA, Osinga AJ, Deschietere J, Lyimo IN, et al. Electrostatic coating enhances bioavailability of insecticides and breaks pyrethroid resistance in mosquitoes. Proc Natl Acad Sci USA. 2015;112:12081–12086. doi: 10.1073/pnas.1510801112. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Snetselaar J, Andriessen R, Suer RA, Osinga AJ, Knols BG, Farenhorst M. Development and evaluation of a novel contamination device that targets multiple life-stages of Aedes aegypti. Parasit Vectors. 2014;7:200. doi: 10.1186/1756-3305-7-200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Knols BG, Njiru BN, Mathenge EM, Mukabana WR, Beier JC, Killeen GF. MalariaSphere: a greenhouse-enclosed simulation of a natural Anopheles gambiae (Diptera: Culicidae) ecosystem in western Kenya. Malar J. 2002;1:19. doi: 10.1186/1475-2875-1-19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Odiere M, Bayoh MN, Gimnig J, Vulule J, Irungu L, Walker E. Sampling outdoor, resting Anopheles gambiae and other mosquitoes (Diptera: Culicidae) in western Kenya with clay pots. J Med Entomol. 2007;44:14–22. doi: 10.1093/jmedent/41.5.14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.WHO. Guidelines for testing mosquito alduticides for indoor residual spraying and treatment of mosquito nets. Geneva: World Health Organization; 2006.
- 33.Sternberg ED, Waite JL, Thomas MB. Evaluating the efficacy of biological and conventional insecticides with the new ‘MCD bottle’ bioassay. Malar J. 2014;13:499. doi: 10.1186/1475-2875-13-499. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Mboera LE, Kihonda J, Braks MA, Knols BG. Short report: influence of centers for disease control light trap position, relative to a human-baited bed net, on catches of Anopheles gambiae and Culex quinquefasciatus in Tanzania. Am J Trop Med Hyg. 1998;59:595–596. doi: 10.4269/ajtmh.1998.59.595. [DOI] [PubMed] [Google Scholar]
- 35.Verhulst NO, Loonen JA, Takken W. Advances in methods for colour marking of mosquitoes. Parasit Vectors. 2013;6:200. doi: 10.1186/1756-3305-6-200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.White GB. Anopheles gambiae complex and disease transmission in Africa. Trans R Soc Trop Med Hyg. 1974;68:278–301. doi: 10.1016/0035-9203(74)90035-2. [DOI] [PubMed] [Google Scholar]
- 37.Von Seidlein L, Ikonomidis K, Bruun R, Jawara M, Pinder M, Knols BG, et al. Airflow attenuation and bed net utilization: observations from Africa and Asia. Malar J. 2012;11:200. doi: 10.1186/1475-2875-11-200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Waite JL, Lynch PA, Thomas MB. Eave tubes for malaria control in Africa: a modelling assessment of potential impact on transmission. Malar J. 2016;15:449. doi: 10.1186/s12936-016-1505-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Abbott M, Johns B. PMI IRS Country Programs: Comparative Cost Analysis, August 11, 2011–December 31, 2012. Africa Indoor Residual Spraying (AIRS) Project, Abt Associates Inc., Bethesda; 2013.
- 40.WHO. Global plan for insecticide resistance management in malaria vectors. Geneva: World Health Organization; 2012.
- 41.Ogoma SB, Lweitoijera DW, Ngonyani H, Furer B, Russell TL, Mukabana WR, et al. Screening mosquito house entry points as a potential method for integrated control of endophagic filariasis, arbovirus and malaria vectors. PLoS Negl Trop Dis. 2010;4:e773. doi: 10.1371/journal.pntd.0000773. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Wilson AL, Dhiman RC, Kitron U, Scott TW, Van den Berg H, Lindsay SW. Benefit of insecticide-treated nets, curtains and screening on vector borne diseases, excluding malaria: a systematic review and meta-analysis. PLoS Negl Trop Dis. 2014;8:e3228. doi: 10.1371/journal.pntd.0003228. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Golding N, Wilson AL, Moyes CL, Cano J, Pigott DM, Velayudhan R, et al. Integrating vector control across diseases. BMC Med. 2015;13:249. doi: 10.1186/s12916-015-0491-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Okumu FO. The paradigm of eave tubes: scaling up house improvement and optimizing insecticide delivery against disease-transmitting mosquitoes. Malar J. 2017;16:207. doi: 10.1186/s12936-017-1859-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.