Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2017 Aug 29;7:9732. doi: 10.1038/s41598-017-10495-8

Toward new gas-analytical multisensor chips based on titanium oxide nanotube array

Fedor Fedorov 1,, Michail Vasilkov 2,3, Andrey Lashkov 3, Alexey Varezhnikov 3, Dirk Fuchs 4, Christian Kübel 5, Michael Bruns 6, Martin Sommer 7, Victor Sysoev 3,8,
PMCID: PMC5575241  PMID: 28852172

Abstract

Reliable environmental monitoring requires cost effective but highly sensitive and selective gas sensors. While the sensitivity of the sensors is improved by reducing the characteristic dimensions of the gas-sensing material, the selectivity is often approached by combining the sensors into multisensor arrays. The development of scalable methods to manufacture such arrays based on low-dimensional structures offers new perspectives for gas sensing applications. Here we examine an approach to produce multisensor array chips based on the TiOx nanotube layers segmented by multiple Pt strip electrodes. We study the sensitivity and selectivity of the developed chip at operating temperatures up to 400 °C towards organic vapors in the ppm range. The results indicate that the titania nanotubes are a promising material platform for novel cost-effective and powerful gas-analytical multisensor units.

Introduction

The development of gas sensors with advanced characteristics is driven by the necessity of fast, reliable and cheap monitoring of the environment1 which is especially important for various emerging tasks2. The most remarkable success in that field is expected in material science of gas-sensitive elements primarily matured from technologies which allow one designing nano-dimensional structures3, 4. The targeted sensor characteristics are higher sensitivity, stability and selectivity5, 6 which should be combined with low production cost and low energy consumption of the final units68.

So far, metal oxide semiconductors are recognized as materials which fully meet the requirements of commercial gas sensors and have a great potential to advance further, mainly through application of nanotechnologies9. The general approach to greatly enhance their sensitivity is a reduction of the characteristic dimensions of the crystallites/grains composing the material10. This enhances the impact of surface processes on the total conductivity of the material as the ratio between Debye length and structure size increases11. However, 3D-nanosized oxide structures might be rather unstable especially at elevated temperatures which are conventionally employed to activate the sensors, particularly chemiresistors12, what questions their stability. In order to address this issue, quasi-1D structures such as nanowires, nanobelts or nanotubes (NTs) are considered to be the promising candidates for a new generation of gas sensors (see recent reviews1315 and references therein). Still, the selectivity remains to be the most challenging aspect because metal oxide semiconductors are fundamentally unselective for chemisorbed gas species. Therefore, the most powerful way is to combine various sensors16, including those based on quasi 1D structures17, into arrays and process the obtained vector signal by pattern recognition techniques.

The quasi 1D oxide structures can be synthesized via gas-based or solution-based techniques1821. The second one is thought to be more suitable for mass production because of lower cost and better control the surface area to define the thickness at the nanoscale22. Among quasi-1-D structures, NTs are distinguished by their high specific surface due to their hollow structure with inner and outer surfaces that are exposed to the gases which makes it easier to fully deplete the oxide from free carriers due to surface localization under chemisorption and catalytic processes. That favors a “transduction function” in this material for sensor applications while a “receptor function” is still defined by a preferential oxide crystalline phase20, 23.

In this report, we consider NTs of titanium dioxide which can be reliably fabricated using high yield protocols24. The most cost effective and well established technology is anodization of titanium in Fcontaining electrolytes which is appropriate for mass-scaling20. By properly choosing the anodization bias one can tune fabricating oxide NT layers with precise control of the diameter, height, wall thickness of the tubes, inter-tube distance, thickness of the barrier layer, etc.25. This renders the material to be promising for chemiresistors using a conventional two-electrode design2630. Although, a realization of these sensors is challenged by a negative influence of titanium underlayer which shunts NTs and leads to poor electrical contacts which reduces the reliability of the devices31.

Despite some success in enhancing the sensitivity of the TiO2 NT-based sensors, the selectivity of gas identification remains unresolved. Even the approaches to functionalize the NTs by various dopants have not allowed one obtaining absolute sensitivity to only one gas32, 33. Therefore, here we consider employing a multisensor approach34 to be realized possibly in the cheapest design35 able in frames of microelectronic technologies by segmenting the pristine NT array by multiple co-planar electrodes. In particular, we demonstrate the capability of the chip to selectively detect few exemplary organic vapors at ppm concentrations.

Results

The process to employ the titanium dioxide NTs in the multisensor chip includes (Fig. 1) primarily an anodization of the titanium foil in accordance with known protocols20, 25, 36, 37. The as-anodized samples are further etched for removing the remained metal in absolute methanol/ Br2 solution38 in order to extract the pristine TiOx NT array. The full details of the processes are given in Methods. Then, the TiOx NT array is cleaned in pure alcohols and placed for floating over the distillated water surface. This array is then picked up and thoroughly positioned over the Si/SiO2 multielectrode chip substrate39. The as-prepared chip is dried for few hours at room temperature in air.

Figure 1.

Figure 1

The scheme of fabrication the multisensor chip based on TiOx NT array: (ae) denote respectively Ti foil (a), Ti foil with as-prepared NT array (b), the extracted NT array (c), the NT array placed over the chip (d), the scheme of multisensor chip wired into 50-pin ceramic card (e).

The Si/SiO2 chip substrate equipped with multiple Pt strip electrodes provides a number (up to 38) of NT array segments whose electrical/chemiresistive properties are measured independently.

Following the transfer into the chip the TiOx NT array possesses a structural integrity as evidenced by scanning electron microscopy (SEM) inspection (Fig. 2a); the NTs are characterized with a distinct morphology (Fig. 2b).

Figure 2.

Figure 2

Characterization of the TiOx NT arrays used in the multisensor chip: (a) SEM image taken of the chip surface covered with NT array; (b) HAADF-STEM image, the inset shows a surface rendering of the 3D STEM tomographic reconstruction viewed along the NT length; (c,d) SAED patterns of as-grown NTs and NTs annealed at 400 °C, respectively; (e,f) the XPS peaks related to Ti 2p (e) and O 1s (f) for the as-grown NTs, red lines show the envelope curves of all fitted peaks to compare with the experimental data (open circles).

The NTs are stand vertically to be almost perpendicular to the chip surface that means the NT open endings are positioned towards the outer atmosphere, including gas vapors under exposure. The mean NT inner diameter D and the mean wall thickness d are 102.7 ± 18.1 nm and 14.5 ± 5.2 nm, respectively, while the NT density is ca. 4.3·109 cm−2. The SEM imaging of the array layer cross-section has proved the height of the NTs to be in range of 0.9–1.2 μm. This height ensures an easy gas access to NTs surface and according to Albu et al.40 allows one staying adhered to chip surface and free of cracks under heating to temperatures higher than 300 °C which are applied for the activation of chemiresistive effect in the NTs and chip operation.

In order to clarify the structure and morphology of NTs we have extracted the NT array out of the same batch as the ones employed in the chip for additional characterization by high-angle annular dark field-scanning transmission electron microscopy (HAADF-STEM) and X-ray photoelectron spectroscopy (XPS) techniques; the details are given in Methods.

Moreover, we have analyzed NTs in as-grown state and one following annealing at 400 °C for 24 h in air atmosphere in order to simulate conditions of chip operation. The recorded HAADF-STEM images of both kinds of samples, as-grown and annealed ones, show that the TiOx NTs are closely packed into an array where adjacent NTs have a distance of a few nm, which favors good gas access (Fig. 2b and Supplementary). The annealing at 400 °C does not change the tubular structure of the arrays. The 3D STEM tomographic reconstruction of the whole array indicates the existence of interconnections between NTs along their whole height (see inset at Fig. 2b and Supplementary videos). Some of the NTs bifurcate that increases their connection pathways and specific surface area. Selected area electron diffraction (SAED) supports that the TiOx NTs are mostly amorphous in the as-grown state (Fig. 2c) to be organized into polycrystalline structure at anatase TiO2 phase after the annealing (Fig. 2d). The anatase crystal structure of annealed NTs is manifested by lattice strong reflections of (101), (103), (105) planes corresponding to d-values of 3.52 Å, 2.37 Å, 1.75 Å and reflections from other crystal planes (see Supplementary).

The XPS study of the as-grown NT array placed over Au-coated Si/SiO2 substrate yields that Ti 2p3/2 peak is positioned at 459.0 eV and the corresponding O 1s peak is observed at 530.3 eV, both in a good agreement with literature references41. Surface Ti-OH groups are indicated by the O 1s peak at 531.2 eV which cannot be seen in the energy region related to Ti 2p due to a low intensity. The weak higher binding energy O 1s peak at 532.4 eV corresponds to C-O groups and corroborates with C 1s signal from surface contaminations component observed at 289.1 eV (Fig. 2e, Supplementary). The XPS survey spectrum also suggests the presence of fluorine traces in the as-grown NTs which stem from electrolyte residues and are removed after annealing of NTs at 400 °C in accordance with literature42. Still, other studies support possible fluctuating of the foreign elements, [F] and [C], at low concentrations in NTs43 and the existence of Ti in different oxidation state close to Ti/TiO2 interface44. Such minor variations of structure and elemental composition in NTs have been out of XPS detection in our samples but still could contribute to the observed differences in local electrical and gas-sensitive properties along NT array membrane as further discussed.

Based on the relative intensity of the Ti 2p3/2 and O 1s peaks, the surface [O]/[Ti] atomic ratio is calculated to be about 1.92. The annealing of NTs at 400 °C in air increases the oxygen content towards attainment of the stoichiometry ratio equal to approx. 1.95. Obviously, even in annealed state the TiOx NTs appear to be non-stoichiometric with an oxygen deficiency which is a major prerequisite to observe a chemiresistive effect45, 46.

In order to activate and stabilize the as-prepared NTs47 for gas sensing tests, we have primarily heated the NT-based multisensor chip up to 400 °C for 24 h in air atmosphere and then carried out the isothermal electrical measurements in RT-400 °C range. At operating temperatures lower than 200 °C the NT array segment resistance over the chip was too high to be read out by our electronic measuring units (see Methods). In the temperature range of 200–400 °C, the I-V curves measured for the NT array segments have been found to be nearly linear (Fig. 3a) in air and in the test vapors (isopropanol, ethanol and acetone) mixed with air. This reasonably indicates a good contact between NTs and the electrodes without significant Schottky barriers. A temperature increase from 200 °C to 400 °C leads to a drop of the mean resistance of the NT array segments in air from tens of GOhms to hundreds MOhms (see Supplementary) following a semiconducting behavior. The activation energy calculated from the conductance-vs-temperature curve is around 0.44 eV which correlates well with the reported values for polycrystalline TiO2 48. This value originates from the potential barriers between adjacent NTs49 and/or the energy levels of local states related to oxygen vacancies45, 46 in the oxide gap which are involved in electron exchange processes at the NT surface.

Figure 3.

Figure 3

The electrical characterization of TiOx NT array based multisensor chip: (a) I–V curves recorded from three exemplary segments under constant flow (100 sccm) of laboratory air at 350 °C; (b) the dependence of chip segments response to 10 ppm of ethanol, isopropanol, and acetone on operating temperature; (c) the dependence of chip segments response on vapor (ethanol, isopropanol, and acetone) concentration in air at 350 °C; (d) the variations of the chip segments resistances, R(t), to pulses of isopropanol at different ppm concentrations under operating temperature of 350 °C; thick black line denotes the segments median resistance.

Following the chip exposure towards isopropanol, ethanol and acetone vapors, 5–10 ppm concentrations, in mixture with laboratory air at 30–35 rel. % humidity, we have observed a clear chemiresistive effect in NTs at all operating temperatures in 200–400 °С range. The maximum gas response as a relative resistance change, ΔR/R air, in the vapor-enriched air has been observed at 350 °C (Fig. 3b). At this temperature, the median NT array segments response to isopropanol and acetone of 10 ppm concentration is close to 38% while one to 10 ppm of ethanol is about 14%. The concentration dependence of the gas response at this temperature follows Freundlich isotherm, ΔR/R air  = kC n, where power low index n for isopropanol, ethanol and acetone is about 0.4, 0.9, 0.6, correspondingly (Fig. 3c) which is quite typical for the most metal oxides50. The observed signals have been stable, at least for few days (see Supplementary).

These remarkable differences in responses to these gases are caused by variations in chemical adsorption and dissociation of these molecules at the NT surface that provides a background to selective recognition of these vapors by multisensor chip array as further discussed. Here, it is worth noting that the change of the median resistance exceeds 8% to 5 ppm of isopropanol already at 200 °C what indicates rather low gas detection limit for the developed multisensor. Figure 3d shows the typical reduction of resistance of exemplary segments of TiOx NT array when exposed to isopropanol vapors at 350 °C which is optimal one to observe the chemiresistive effect. The similar data have been observed in case of other test vapors at different temperatures.

It is clear that the organic vapor traces substantially decrease the resistance of the segments in accordance with n-type semiconductor response of non-stoichiometric TiO2. Still, the spatial inhomogeneous local morphology of the NT array across the chip segments results in the variation of both the resistance and gas sensitivity. It allows one employing it to build a vector signal whose components are constitued by signals from the gas-sensitive segments in the chip and approach the gas selectivity in the framework of known multisensor concept16. In order to process the NT-based multisensor vector response to the test vapors we have applied the Linear Discriminant Analysis (LDA) which maximizes the vector variations induced by different vapors and minimizes the vector scatters under exposure to certain vapor51. The confidence probability to build the LDA clusters related to gases has been installed to be equal to 0.95. By these means, we have tested all the multisensor chip vector signals recorded at operating temperatures in 200–400 °C range (Fig. 4). In order to build the training set in the LDA space the sampling of 10 vector signals recorded under each atmosphere has been employed while other recorded signals were served for testing. Here, we define the selectivity as an average Mahalanobis distance between clusters in the LDA space52. This parameter allows us to estimate quantitatively the quality of gas recognition under various working conditions of the chip. As we found, the selectivity strongly depends on the operating temperature (Fig. 4b,c). The temperature enhancement from 200 °C to 400 °C results in 2-order change in the mean Mahalanobis distance between the clusters from ca. 0.8 to 61.7, correspondingly, in the 3-dimensional LDA coordinate system. This selectivity estimation clearly correlates with gas response behavior with temperature up to 350 °C: the higher response means higher selectivity. However, 400 °C is even more favorable for selectivity while gas response slightly reduces. These data indicate that the operating temperature facilitates not only the at-surface charge-exchange processes but also the minor variations of potential barriers observed in NT-to-NT percolation paths in the array.

Figure 4.

Figure 4

The LDA processing of vector responses of NT array-based multisensor chip to test organic vapors, 10 ppm concentration: dependence of the average Mahalanobis distance between the centers of vapor-related LDA clusters as a function of operating temperature. The projections of the generated LDA space into primary two-component plane are centered at the obtained points referring to Mahalanobis distance. The inset is the LDA 3-component diagram built for the chip operated at 350 °C: 1-air,2-acetone,3-ethanol,4- isopropanol. All the spheres are calculated at 0.95 confidence level to frame data training clusters; the points are related to the test responses.

While the electron exchange between the chemisorbed species and semiconducting oxide surface depends mostly on the material itself, the micro- and mesostructure of the layer, its porosity and characteristic geometry substantially contribute to the overall NT array resistance measured at different environments53. Basically, the two dominant fundamental mechanisms, the depletion of the oxide material by free electrons and existence of potential barriers in contacts between the NTs, interplay in the chemiresistive response of the NT array. Under air conditions the NT surface is fully covered by oxygen and hydroxyl chemisorbed species which localize the electrons from the oxide conduction band54. This induces at-surface space charge region whose width in the oxide is comparable with the average NT wall thickness and crystallites. Taking the obtained NT array resistance values measured in air conditions we assess55 the free electron concentration, n=geμhRs, where e is elementary charge, h the tube height, R s the NT array sheet surface resistance per square (see Supplementary), μ the electron mobility, which we consider equal to approx. 0.1 cm2/Vs, characteristic for polycrystalline TiO2 56. The geometry coefficient g=(D+2d)22d(D+d) accounts for reduction of in-fact volume of the NT array sheet when compared to compact layer due to the porous tubular geometry and confining the electron pathway within the NT walls. Considering the obtained magnitudes of D and d the estimated value of g is equal to approx. 5.1. For instance, at operating temperature of 350 °C one gets n equal to approx. 3.3 ± 0.4·1013 cm−3 that is lower by 3–4 orders of magnitude when compared to concentrations reported for a single anatase NT measured in vacuum conditions57. The corresponding Debye length, Ld=εε0kTe2n, where k is Boltzmann constant, ε 0 the electric constant, ε the dielectric permittivity of anatase (equal to approx. 31)58, 59, T the operating temperature, at these conditions goes to micrometer range that obviously exceeds the NT wall. Therefore, under air conditions the Fermi level in the NTs is pinned at the local states induced by oxidizing/hydroxyl adspecies in the oxide gap that is ordinarily described as a flat-band approximation60. It results in remarkable reduction both the free electron concentration in the NT wall and the electron mobility due to enhancing the potential barrier, ψ B, between NTs61. Consequently, this originates a high NT array resistance observed. So, the electron transport in such structures is mainly governed by carrier-depleted NT walls contacting each other like in the case of grains in polycrystalline samples54.

The exposure to reducing organic vapors releases the at-surface localized electrons to conductance band and decreases ψ B 50, 55. We consider the only electronic component of the oxide conductance because the operating temperatures below 400 °C are still not enough to stimulate a significant exchange between surface and bulk of NTs by intrinsic defects58. So, under application of electric field the electrons go through NT adjacent walls whose potential barrier height and “tunneling density” depend on a gas environment (Fig. 5). Thus, the whole NT array looks like a network of percolating tubes where analyte molecules modify the conduction pathways upon interaction with NT surfaces and junctions. The surface reactions between the gas molecules (see Fig. 5a) and/or their direct catalysis include a dissociation accompanied by an exchange of charged species that involves different amounts of charge localized by chemisorbed species.

Figure 5.

Figure 5

A schematic representation to show the change in the conductivity and conduction pathway for electrons through TiOx NT array at two environments - air and mixture of air and reducing agents: (a) the modification of potential barrier heights following the adsorption of the species of different origin and their surface reactions; (b) SEM images of the NT array from top and side views corresponding to the presented scheme.

This explains the higher response of the NTs towards isopropanol and acetone vapors when compared to one versus ethanol. Moreover, a stochastic combination of NT-to-NT contacts at each chip segment underlies the diversity of their gas-sensing properties along the array that allows us to build the chip vector signal selective to gases.

In conclusion, the obtained data clearly show that TiOx NT array is a promising material to employ not only for the development of conventional gas sensors but gas-analytical multisensor chips as well. We have introduced the approaches to build up such chips which include primarily an anodization of titanium into oxide nanotubular layer with following removal of residual metal and secondly the transfer of the layer over the multielectrode Si/SiO2 chip substrate by a method similar to Langmuir-Blodgett one. The tested samples of NT array- based multisensor chip have exhibited high sensitivity towards organic vapors in ppm range. The intrinsic stochastic inhomogeneities of the array along the chip yield obtaining the selectivity of gas discrimination by processing the multisensor vector signal generated by chip segments via pattern recognition technique. Still, the chip design allows one further advancing the selectivity by application of inhomogeneous heating and/or other external modifications.

Methods

TiOx NT array fabrication

TiOx NTs are prepared by anodization of Ti, 99.6% (Sigma-Aldrich) foil of 127 µm thickness. Prior to anodization the titanium foil has been immersed into acetone and ethanol, both for 10 min, in sequence under sonification and then rinsed in deionized water (18.2 MΩcm). The titanium foil is characterized with a roughness less than 0.7 µm measured with surface profiler (Veeco DekTak 150). The electrochemical anodization has been performed in a Teflon® cell in two-electrode configuration with a platinum mesh as cathode biased at 30 V for 1 hour at room temperature using electrolyte based on glycerol/water 3:1 solution with addition of 0.8% NH4F (Supplementary Figure 1). All chemicals have been provided to be at least of analytical purity (Sigma-Aldrich). The electrode area is separated by O-ring rubber to expose a Ti surface, 0.79 cm2, to the electrolyte. The anodization experiments have been carried out using a high-voltage potentiostat (Keithley 2410 source meter) connected to a digital multimeter (Keithley 2700 multimeter /data acquisition system) interfaced to personal computer (PC). The TiOx NT array is afterwards rinsed in ethanol and is dried at room temperature for 0.5–1 h. The Ti sublayer remains have been selectively dissolved in an absolute methanol/Br2 solution, 1:9 vol., at 20 °С for 2 hours according to ref. 38. Then, the obtained layer has been positioned over the Si/SiO2 chip equipped with multiple planar electrodes. Thermal treatment of titania NTs has been performed in PEO-601 oven (ATV Technologie GmbH) in air atmosphere at 400 °C during 24 h. Following the annealing the samples have been rinsed by distilled water and dried in air.

TiOx NT array characterization

The morphological characterization of the NT array has been carried out using a scanning electron microscope (AURIGA® CrossBeam® workstation, Carl Zeiss) equipped with an energy dispersive X-ray (EDX) detector. The NT structure has been studied by transmission electron microscopy (TEM) using an aberration (image) corrected Titan 80–300 (FEI Company) equipped with a US1000 (Gatan) CCD camera. After mechanical removing the TiOx NTs from the substrate, they have been dispersed in n-heptane by sonification and deposited on a carbon coated Cu grid (Quantifoil) for the TEM analysis. For an electron tomographic characterization in HAADF-STEM mode, 15 nm gold nanoparticles (University of Utrecht) were added for alignment and a tilt-series recorded from −60° to 60° in 2° steps. The tilt-series alignment was performed using IMOD (University of Colorado) and the 3D volume reconstructed using the SIRT algorithm implemented in Inspect3D (FEI Company). The Supplementary video shows a volume rendering of the 3D structure of the NT array morphology and a surface rendering of a selected part of the 3D reconstruction prepared in Amira (FEI Company).

The X-ray photoelectron spectroscopy (XPS) measurements have been conducted using a K-Alpha+ XPS spectrometer (Thermo Fisher Scientific, East Grinstead, UK). Data acquisition and processing using the @Thermo Avantage software are described elsewhere62. We have utilized Si substrate with sputtered Au layer, approx. 1 µm thick, to place the titania NT array after the metallic Ti is removed. All samples have been measured using a microfocused monochromated Al Kα X-ray source of 30–400 µm spot size. The K-Alpha charge compensation system is employed during analysis using electrons of 8 eV energy and low-energy argon ions to prevent any localized charge build-up. The spectra are fitted with one or more Voigt profiles; the binding energy uncertainty is ±0.2 eV. The analyzer transmission function, Scofield sensitivity factors63 and effective attenuation lengths (EALs) for photoelectrons are applied for quantification. EALs are calculated using the standard TPP-2M formalism64. All spectra have been referenced to the C 1s peak of hydrocarbon at 285.0 eV binding energy controlled by means of the well-known photoelectron peaks of metallic Cu, Ag, and Au.

The multielectrode substrate as a platform for the multisensor chip

We have utilized multielectrode chip based on Si/SiO2 substrate equipped with 39 Pt strip electrodes which define, if necessary, 38 segments of the NT array as a maximum number39. The inter-electrode distance is about 80 µm, electrode width is 100 µm, and the electrodes are 1 μm thick. All the electrodes have a length of about 4 mm that defines the surface area of about 4 × 8 mm2 whose part or total is covered by NT array. The frontside of the substrate has two meander-shaped Pt thermoresistiors at the edges to monitor the operating temperature which is adjusted by four meander heaters located at the backside. The operating temperature is maintained by corresponding PC-driven electronics unit with accuracy of 1 °С while the temperature distribution at isothermal chip operation can be of ±10 °C52.

We have tested a number of chips in preliminary studies, the reported data belong to one exemplary chip.

Gas response measurements with NT array multisensor chip

The response of multisensor chip equipped with TiOx NT array towards different organic vapors has been studied using a setup which includes home-made data acquisition unit, test gas generator, gas delivery tubes and electronic unit to maintain and monitor the chip operating temperature. Data acquisition module (National Instruments USB-6259) together with current pre-amplifier (SRS, SR570) has provided the resistivity measurements up to tens GOhms of each segment in the chip. To read out the total array resistances we have employed a multiplexing card for switching between the segments. Test vapor mixtures with laboratory air have been obtained with gas generator (Owlstone, UK) which employs heated permeation tubes containing a test liquid to yield vapors of several ppm of concentration under equilibrium conditions. The vapors of the same reducing origin, alcohols and acetone, have been utilized as test ones. The vapors have fed the chip by series of 10 min duration interrupted by pulses of pure laboratory air for 10–25 minutes to ensure the recovery of the chip segment resistances. The concentration of vapors in mixture with air has been maintained to be 5, 7, 10 ppm for each one. The laboratory air is delivered by an oil-free compressor as is to be of normal humidity level in range of approx. 30–35 rel. %. The all gases have been supplied in a flow mode with 100 sccm rate. We have utilized only the data for NT array segments with resistivity less than 10 GOhm at maximum operating temperature of 400 °C. Therefore, 16 segments of the multielectrode chip have been considered in the reported data.

Electronic supplementary material

Supplementary Info (1.7MB, pdf)
Video 1 (2.1MB, avi)
Video 2 (2.9MB, avi)

Acknowledgements

We thank V. Sakharov for technical assistance on material characterization and Prof. A. Kolmakov (NIST) for help in reviewing the manuscript. F.S.F., M.U.V., A.V. L., A.S.V., V.V.S. thank Russ. Ministry of Education and Science for a partial support by grants no. 16.1119.2017/4.6 and K3-2016-031 issued to MISiS. M.B. thanks German Fed. Ministry of Economics and Technology to support the K-Alpha + instrument. The authors thanks Karlsruhe Nano Micro Facility (KNMF, KIT, Germany), project 2016-016-012029.

Author Contributions

F.F., M.V. and V.S. conceived the idea and designed the experiments. M.V. contributed extensively to sample fabrication. A.L., A.V. contributed to gas sensing experiments. F.F., M.V., D.F., Ch.K., M.B. carried out the material characterization. F.F., V.S. contributed to the data analysis and discussion of mechanisms involved. All authors contributed to writing the paper.

Competing Interests

The authors declare that they have no competing interests.

Footnotes

Electronic supplementary material

Supplementary information accompanies this paper at doi:10.1038/s41598-017-10495-8

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Fedor Fedorov, Email: fedorov_fs@daad-alumni.de.

Victor Sysoev, Email: vsysoev@sstu.ru.

References

  • 1.Lewis A, Edwards P. Validate personal air-pollution sensors. Nature. 2016;535:29–31. doi: 10.1038/535029a. [DOI] [PubMed] [Google Scholar]
  • 2.Lichtenstein A, et al. Supersensitive fingerprinting of explosives by chemically modified nanosensors arrays. Nat. Commun. 2014;5 doi: 10.1038/ncomms5195. [DOI] [PubMed] [Google Scholar]
  • 3.Zhang A, Lieber CM. Nano-bioelectronics. Chem. Rev. 2016;116:215–257. doi: 10.1021/acs.chemrev.5b00608. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Thamri A, et al. MHDA-functionalized multiwall carbon nanotubes for detecting non-aromatic VOCs. Sci. Rep. 2016;6 doi: 10.1038/srep35130. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Yamazoe N. Toward innovations of gas sensor technology. Sensors Actuators B Chem. 2005;108:2–14. doi: 10.1016/j.snb.2004.12.075. [DOI] [Google Scholar]
  • 6.Di Natale C, Paolesse R, Martinelli E, Capuano R. Solid-state gas sensors for breath analysis: a review. Anal. Chim. Acta. 2014;824:1–17. doi: 10.1016/j.aca.2014.03.014. [DOI] [PubMed] [Google Scholar]
  • 7.Strelcov E, et al. Evidence of the self-heating effect on surface reactivity and gas sensing of metal oxide nanowire chemiresistors. Nanotechnology. 2008;19 doi: 10.1088/0957-4484/19/35/355502. [DOI] [PubMed] [Google Scholar]
  • 8.Semancik, S. et al. Microhotplate platforms for chemical sensor research. Sensors Actuators, B Chem. 77 (2001).
  • 9.Korotchenkov, G. & Sysoev, V. V. In Chemical sensors: comprehensive sensor technologies, Volume 4: Solid state devices (ed. Korotchenkov, G.) 53–186 (Momentum Press, LLC, 2011).
  • 10.Das S, Jayaraman V. SnO2: a comprehensive review on structures and gas sensors. Prog. Mater. Sci. 2014;66:112–255. doi: 10.1016/j.pmatsci.2014.06.003. [DOI] [Google Scholar]
  • 11.Barsan N, Koziej D, Weimar U. Metal oxide-based gas sensor research: How to? Sensors Actuators B Chem. 2007;121:18–35. doi: 10.1016/j.snb.2006.09.047. [DOI] [Google Scholar]
  • 12.Sysoev VV, et al. Percolating SnO2 nanowire network as a stable gas sensor: direct comparison of long-term performance versus SnO2 nanoparticle films. Sensors Actuators B Chem. 2009;139:699–703. doi: 10.1016/j.snb.2009.03.065. [DOI] [Google Scholar]
  • 13.Comini E, et al. Quasi-one dimensional metal oxide semiconductors: Preparation, characterization and application as chemical sensors. Prog. Mater. Sci. 2009;54:1–67. doi: 10.1016/j.pmatsci.2008.06.003. [DOI] [Google Scholar]
  • 14.Arafat MM, Dinan B, Akbar SA, Haseeb ASMA. Gas sensors based on one dimensional nanostructured metal-oxides: a review. Sensors (Basel). 2012;12:7207–58. doi: 10.3390/s120607207. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Zhao Z, Tian J, Sang Y, Cabot A, Liu H. Structure, Synthesis, and Applications of TiO2 Nanobelts. Adv. Mater. 2015;27:2557–2582. doi: 10.1002/adma.201405589. [DOI] [PubMed] [Google Scholar]
  • 16.Persaud K, Dodd G. Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose. Nature. 1982;299:352–355. doi: 10.1038/299352a0. [DOI] [PubMed] [Google Scholar]
  • 17.Sysoev V, Button B, Wepsiec K, Dmitriev S, Kolmakov A. Toward the nanoscopic ‘electronic nose’: hydrogen vs carbon monoxide discrimination with an array of individual metal oxide nano- and mesowire sensors. Nano Lett. 2006;6:1584–1588. doi: 10.1021/nl060185t. [DOI] [PubMed] [Google Scholar]
  • 18.Dasgupta NP, et al. Semiconductor nanowires – synthesis, characterization, and applications. Adv. Mater. 2014;26:2137–2184. doi: 10.1002/adma.201305929. [DOI] [PubMed] [Google Scholar]
  • 19.Devan RS, Patil RA, Lin J-H, Ma Y-R. One-dimensional metal-oxide nanostructures: recent developments in synthesis, characterization, and applications. Adv. Funct. Mater. 2012;22:3326–3370. doi: 10.1002/adfm.201201008. [DOI] [Google Scholar]
  • 20.Roy P, Berger S, Schmuki P. TiO2 nanotubes: synthesis and applications. Angew. Chemie Int. Ed. 2011;50:2904–2939. doi: 10.1002/anie.201001374. [DOI] [PubMed] [Google Scholar]
  • 21.Zwilling V, Aucouturier M, Darque-Ceretti E. Anodic oxidation of titanium and TA6V alloy in chromic media. An electrochemical approach. Electrochim. Acta. 1999;45:921–929. doi: 10.1016/S0013-4686(99)00283-2. [DOI] [Google Scholar]
  • 22.Regonini D, Bowen CR, Jaroenworaluck A, Stevens R. A review of growth mechanism, structure and crystallinity of anodized TiO2 nanotubes. Mater. Sci. Eng. R Reports. 2013;74:377–406. doi: 10.1016/j.mser.2013.10.001. [DOI] [Google Scholar]
  • 23.Guo W, et al. Systematic investigation on the gas-sensing performance of TiO2 nanoplate sensors for enhanced detection on toxic gases. Mater. Res. Bull. 2016;73:302–307. doi: 10.1016/j.materresbull.2015.09.012. [DOI] [Google Scholar]
  • 24.Rao, B. M., Torabi, A. & Varghese, O. K. Anodically grown functional oxide nanotubes and applications. MRS Commun. 375–396 (2016).
  • 25.Varghese OK, Paulose M, Grimes CA. Long vertically aligned titania nanotubes on transparent conducting oxide for highly efficient solar cells. Nat Nano. 2009;4:592–597. doi: 10.1038/nnano.2009.226. [DOI] [PubMed] [Google Scholar]
  • 26.Lin S, Li D, Wu J, Li X, Akbar SA. A selective room temperature formaldehyde gas sensor using TiO2 nanotube arrays. Sensors Actuators B Chem. 2011;156:505–509. doi: 10.1016/j.snb.2011.02.046. [DOI] [Google Scholar]
  • 27.Lu HF, et al. Amorphous TiO2 nanotube arrays for low-temperature oxygen sensors. Nanotechnology. 2008;19 doi: 10.1088/0957-4484/19/40/405504. [DOI] [PubMed] [Google Scholar]
  • 28.Perillo PM, Rodríguez DF. The gas sensing properties at room temperature of TiO2 nanotubes by anodization. Sensors Actuators B Chem. 2012;171–172:639–643. doi: 10.1016/j.snb.2012.05.047. [DOI] [Google Scholar]
  • 29.Kwon Y, et al. Enhanced ethanol sensing properties of TiO2 nanotube sensors. Sensors Actuators, B Chem. 2012;173:441–446. doi: 10.1016/j.snb.2012.07.062. [DOI] [Google Scholar]
  • 30.Şennik E, Çolak Z, Kilinç N, Öztürk ZZ. Synthesis of highly-ordered TiO2 nanotubes for a hydrogen sensor. Int. J. Hydrogen Energy. 2010;35:4420–4427. doi: 10.1016/j.ijhydene.2010.01.100. [DOI] [Google Scholar]
  • 31.Varghese OK, Gong D, Paulose M, Ong KG, Grimes CA. Hydrogen sensing using titania nanotubes. Sensors Actuators B Chem. 2003;93:338–344. doi: 10.1016/S0925-4005(03)00222-3. [DOI] [Google Scholar]
  • 32.Comini E, Galstyan V, Faglia G, Bontempi E, Sberveglieri G. Highly conductive titanium oxide nanotubes chemical sensors. Microporous Mesoporous Mater. 2015;208:165–170. doi: 10.1016/j.micromeso.2015.01.040. [DOI] [Google Scholar]
  • 33.Moon J, Hedman H-P, Kemell M, Tuominen A, Punkkinen R. Hydrogen sensor of Pd-decorated tubular TiO2 layer prepared by anodization with patterned electrodes on SiO2/Si substrate. Sensors Actuators B Chem. 2016;222:190–197. doi: 10.1016/j.snb.2015.08.054. [DOI] [Google Scholar]
  • 34.Persaud, K. In Electronic Noses and Tongues in Food Science (ed. Méndez, M. L. R.) 1–12 (Academic Press, 2016).
  • 35.Goschnick J. An electronic nose for intelligent consumer products based on a gas analytical gradient microarray. in. Microelectronic Engineering. 2001;57–58:693–704. doi: 10.1016/S0167-9317(01)00553-6. [DOI] [Google Scholar]
  • 36.Richter C, Schmuttenmaer CA. Exciton-like trap states limit electron mobility in TiO2 nanotubes. Nat Nano. 2010;5:769–772. doi: 10.1038/nnano.2010.196. [DOI] [PubMed] [Google Scholar]
  • 37.Close T, Tulsyan G, Diaz CA, Weinstein SJ, Richter C. Reversible oxygen scavenging at room temperature using electrochemically reduced titanium oxide nanotubes. Nat Nano. 2015;10:418–422. doi: 10.1038/nnano.2015.51. [DOI] [PubMed] [Google Scholar]
  • 38.Albu SP, Ghicov A, Macak JM, Hahn R, Schmuki P. Self-organized, free-standing TiO2 nanotube membrane for flow-through photocatalytic applications. Nano Lett. 2007;7:1286–1289. doi: 10.1021/nl070264k. [DOI] [PubMed] [Google Scholar]
  • 39.Sysoev VV, Kiselev I, Trouillet V, Bruns M. Enhancing the gas selectivity of single-crystal SnO2:Pt thin-film chemiresistor microarray by SiO2 membrane coating. Sensors Actuators B Chem. 2013;185:59–69. doi: 10.1016/j.snb.2013.04.087. [DOI] [Google Scholar]
  • 40.Albu SP, Ghicov A, Schmuki P. Lift off strategies for self-organized TiO2 nanotube layers. ECS Trans. 2008;16:195–202. [Google Scholar]
  • 41.Tunc I, Bruns M, Gliemann H, Grunze M, Koelsch P. Bandgap determination and charge separation in Ag@TiO2 core shell nanoparticle films. Surf. Interface Anal. 2010;42:835–841. doi: 10.1002/sia.3558. [DOI] [Google Scholar]
  • 42.Albu SP, et al. Formation of double-walled TiO2 nanotubes and robust anatase membranes. Adv. Mater. 2008;20:4135–4139. [Google Scholar]
  • 43.Lee K, Mazare A, Schmuki P. One-dimensional titanium dioxide nanomaterials: nanotubes. Chem. Rev. 2014;114:9385–9454. doi: 10.1021/cr500061m. [DOI] [PubMed] [Google Scholar]
  • 44.Nguyen QAS, Bhargava YV, Radmilovic VR, Devine TM. Structural study of electrochemically synthesized TiO2 nanotubes via cross-sectional and high-resolution TEM. Electrochim. Acta. 2009;54:4340–4344. doi: 10.1016/j.electacta.2009.03.034. [DOI] [Google Scholar]
  • 45.Göpel W, Rocker G, Feierabend R. Intrinsic defects of TiO2 (110): interaction with chemisorbed O2, H2, CO, and CO2. Phys. Rev. B. 1983;28:3427–3438. doi: 10.1103/PhysRevB.28.3427. [DOI] [Google Scholar]
  • 46.Smith KE, Mackay JL, Henrich VE. Interaction of SO2 with nearly perfect and defect ТiO2 (110) surfaces. Phys. Rev. B. 1987;35:5822–5829. doi: 10.1103/PhysRevB.35.5822. [DOI] [PubMed] [Google Scholar]
  • 47.Zhu K, Neale NR, Miedaner A, Frank AJ. Enhanced charge-collection efficiencies and light scattering in dye-sensitized solar cells using oriented TiO2 nanotubes arrays. Nano Lett. 2007;7:69–74. doi: 10.1021/nl062000o. [DOI] [PubMed] [Google Scholar]
  • 48.Mardare D, Rusu GI. Electrical conduction mechanism in polycrystalline titanium oxide thin films. J. Non. Cryst. Solids. 2010;356:1395–1399. doi: 10.1016/j.jnoncrysol.2010.05.049. [DOI] [Google Scholar]
  • 49.Castro-Hurtado I, et al. Formaldehyde sensing mechanism of SnO2 nanowires grown on-chip by sputtering techniques. RSC Adv. 2016;6:18558–18566. doi: 10.1039/C5RA26105H. [DOI] [Google Scholar]
  • 50.Wolkenstein, T. Electronic Processes on Semiconductor Surfaces during Chemisorption (Consultants Bureau, 1991).
  • 51.Hierlemann A, Gutierrez-Osuna R. Higher-order chemical sensing. Chem. Rev. 2008;108:563–613. doi: 10.1021/cr068116m. [DOI] [PubMed] [Google Scholar]
  • 52.Sysoev VV, Kiselev I, Frietsch M, Goschnick J. Temperature gradient effect on gas discrimination power of a metal-oxide thin-film sensor microarray. Sensors. 2004;4:37–46. doi: 10.3390/s40400037. [DOI] [Google Scholar]
  • 53.Korotcenkov G, Cho BK. The role of grain size on the thermal instability of nanostructured metal oxides used in gas sensor applications and approaches for grain-size stabilization. Prog. Cryst. Growth Charact. Mater. 2012;58:167–208. doi: 10.1016/j.pcrysgrow.2012.07.001. [DOI] [Google Scholar]
  • 54.Barsan N, Weimar U. Conduction model of metal oxide gas sensors. J. Electroceramics. 2001;7:143–167. doi: 10.1023/A:1014405811371. [DOI] [Google Scholar]
  • 55.Kissine VV, Sysoev VV, Voroshilov SA. Individual and collective effects of oxygen and ethanol on the conductance of SnO2 thin films. Appl. Phys. Lett. 2000;76:2391–2393. doi: 10.1063/1.126381. [DOI] [Google Scholar]
  • 56.Tang H, Prasad K, Sanjinès R, Schmid PE, Lévy F. Electrical and optical properties of TiO2 anatase thin films. J. Appl. Phys. 1994;75:2042–2047. doi: 10.1063/1.356306. [DOI] [Google Scholar]
  • 57.Hattori M, et al. Investigation of electrical transport in anodized single TiO2 nanotubes. Appl. Phys. Lett. 2013;102:1–5. [Google Scholar]
  • 58.Diebold U. The surface science of titanium dioxide. Surf. Sci. Rep. 2003;48:53–229. doi: 10.1016/S0167-5729(02)00100-0. [DOI] [Google Scholar]
  • 59.Roberts S. Dielectric constants and polarizabilities of ions in simple crystals and barium titanate. Phys. Rev. 1949;76:1215–1220. doi: 10.1103/PhysRev.76.1215. [DOI] [Google Scholar]
  • 60.Rothschild, A. & Komem, Y. The effect of grain size on the sensitivity of nanocrystalline metal-oxide gas sensors. J. Appl. Phys. 95 (2004).
  • 61.Cai Y, Feng YP. Review on charge transfer and chemical activity of TiO2: mechanism and applications. Prog. Surf. Sci. 2016;91:183–202. doi: 10.1016/j.progsurf.2016.11.001. [DOI] [Google Scholar]
  • 62.Parry KL, et al. ARXPS characterisation of plasma polymerised surface chemical gradients. Surf. Interface Anal. 2006;38:1497–1504. doi: 10.1002/sia.2400. [DOI] [Google Scholar]
  • 63.Scofield JH. Hartree-Slater subshell photoionization cross-sections at 1254 and 1487 eV. J. Electron Spectros. Relat. Phenomena. 1976;8:129–137. doi: 10.1016/0368-2048(76)80015-1. [DOI] [Google Scholar]
  • 64.Tanuma S, Powell CJ, Penn DR. Calculations of electron inelastic mean free paths. Surf. Interface Anal. 1994;21:165–176. doi: 10.1002/sia.740210302. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Info (1.7MB, pdf)
Video 1 (2.1MB, avi)
Video 2 (2.9MB, avi)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES