Abstract
Background
Coins are made of metal, which is generally radiopaque, and so physicians often have the misconception that all coins are detectable by radiography. Here, we report a case of intentionally swallowed coins in the oesophagus of an adult; the coins could not be detected on chest radiography but were detected using computed tomography (CT).
Case presentation
A 46-year-old woman with a history of depression presented to the emergency department after an intentional medication overdose and ingestion of two Japanese 1-yen coins. She complained of persistent retrosternal discomfort. In order to confirm whether the coins were in the oesophagus or trachea, an anteroposterior chest radiograph was obtained; however, no coins were detected. Owing to her persistent symptoms, a chest CT was performed. On the initial CT scan, two 1-yen coins were observed in the oesophagus: one in the middle oesophagus and the other in the lower oesophagus. After the scanning, the patient drank water with permission, but vomited. No coins were found in her vomit, and the symptoms of retrosternal discomfort had completely disappeared. A subsequent CT scan revealed that the two 1-yen coins were in the patient’s stomach.
Conclusions
Japanese 1-yen coins are made of 100% aluminium, which is less radiopaque than the metals that make up coins (nickel, bronze, and lead), and so, they were not visible via chest radiography in our case. Detecting very small or thin radiolucent foreign bodies is not possible using a chest radiograph or contrast oesophagram, but is possible via CT. CT is both increasingly convenient and non-invasive, unlike endoscopy or bronchoscopy, and so, the use of CT scans should be considered in cases of possible radiolucent foreign body ingestion.
Keywords: Oesophageal coins, Radiolucent, CT scan
Background
Swallowed foreign bodies can include various objects, with coins being the most common in children. Coins are made of metal, which is generally radiopaque, and so, physicians often have the misconception that all coins are detectable by radiography. Here, we report a case of intentionally swallowed coins in the oesophagus of an adult; the coins could not be detected on chest radiography but were detected using computed tomography (CT).
Case presentation
A 46-year-old woman with a history of depression presented to the emergency department after an intentional medication overdose and ingestion of two Japanese 1-yen coins. On physical examination, the patient was drowsy owing to an overdose of benzodiazepines and quetiapine; however, her vital signs were within the normal range. There were no abnormal lung sounds and no abdominal tenderness. One hour after her presentation, the patient was alert and oriented, after which she complained of persistent retrosternal discomfort. She did not report dyspnoea or dysphagia.
In order to confirm whether the coins were in the oesophagus or trachea, an anteroposterior chest radiograph was conducted; however, no coins were detected (Fig. 1). The medical team suspected that the coins had already traversed to the stomach or lower gastrointestinal tract, or that she had not swallowed any coins. However, owing to her persistent symptoms, a chest CT was performed. On the initial CT scan, two 1-yen coins were observed in the oesophagus: one in the middle oesophagus and the other in the lower oesophagus (Fig. 2).
After the scan, the patient drank water with permission, but vomited. No coins were found in her vomit, and the symptoms of retrosternal discomfort had completely disappeared. A second CT scan revealed that the two 1-yen coins were in the patient’s stomach. Because there was no need for treatment, the patient was discharged. Two days later, at the follow-up appointment, the patient reported that the coins had been discharged in her faeces.
Conclusions
Swallowed foreign bodies can consist of various items, including small toys, button batteries, press-through packs, and artificial teeth. Coins are the most common foreign bodies found in children [1]. Coins are made of various metals, such as nickel, bronze, and lead, which are generally radiopaque and can be detected via radiography.
The X-ray absorption of a coin depends on its composition, density, and the atomic number of the metal. Japanese 1-yen coins are made of 100% aluminium, which has an atomic number (Z) of 13, compared to nickel and lead, with Z values of 28 and 82, respectively. The atomic number for aluminium is between that of the bone (calcium, Z = 20) and of the soft tissue (Z = 7.5). It is therefore very difficult to distinguish aluminium from other soft tissues [2, 3]. In our case, 1-yen coins could not be detected by chest radiography.
A few studies have reported cases of aluminium-based foreign bodies. Khan reported a case in which a Pakistani 2-rupee coin, also made of aluminium, was faintly visible on a chest radiograph [4]. Kotsenas et al. reported a case in which the aluminium pull tab from a beverage can was aspirated and was not detectable via chest radiography. The pull tab was detected in a chest CT scan 7 months later [2].
Additional reasons for the invisibility of 1-yen coins on the chest radiograph in this particular case include the direction of the X-rays and the location of the coins. In the oesophagus, the coin was located horizontally in relation to the trunk. This horizontal positioning separates the coin from other mediastinal structures or the thoracic spine on a lateral chest radiograph. In addition, the coin could be more easily visualised owing to its thickness in this position.
A contrast oesophagram may also be effective for identifying radiolucent foreign bodies in the oesophagus, while also exposing the patient to less radiation [5]. However, contrast oesophagrams do not possess adequate diagnostic accuracy compared with CT scans, come with a contrast-aspiration risk, and may compromise subsequent endoscopies due to the contrast coating of the foreign body and oesophageal mucosa [6].
It is impossible to detect the presence of a very small or thin radiolucent foreign body on a chest radiograph or contrast oesophagram. For such cases, only a CT scan can detect a radiolucent foreign body in the oesophagus. CT scans are both convenient and non-invasive, unlike endoscopy or bronchoscopy. Therefore, CT scans should be considered in cases of possible radiolucent foreign body ingestion.
Acknowledgements
We would like to acknowledge our ED staff for their support.
Funding
No funding was required in preparation of the manuscript.
Availability of data and materials
Not applicable
Abbreviations
- CT
Computed tomography
- Z
Atomic number
Authors’ contributions
JT, HF, and TS drafted the case presentation and edited the manuscript. All authors read and approved the final manuscript.
Ethics approval and consent to participate
Study approval was obtained from the Institutional Review Board at Tokyo Bay Urayasu Ichikawa Medical Center. The patient has provided permission to publish these features of her case.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Jin Takahashi, Email: tshsf007001@gmail.com.
Takashi Shiga, Email: takshigaemp@gmail.com.
Hiraku Funakoshi, Email: fwhs0754@mb.infoweb.ne.jp.
References
- 1.Jayachandra S, Eslick GD. A systematic review of paediatric foreign body ingestion: presentation, complications, and management. Int J Pediatr Otorhinolaryngol. 2013;77(3):311–317. doi: 10.1016/j.ijporl.2012.11.025. [DOI] [PubMed] [Google Scholar]
- 2.Kotsenas AL, Campeau NG, Oeckler RA, Kuzo RS. Evaluation of suspected aspirated beverage can pull tab: radiographs may not be enough. Case Rep Radiol. 2014;2014:196960. doi: 10.1155/2014/196960. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Stewart GD, Lakshmi MV, Jackson A. Aluminum ring pulls: an invisible foreign body. J Accid and Emerg Med. 1994;11(3):201–203. doi: 10.1136/emj.11.3.201. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Khan YA. Aluminum coins in esophagus: a diagnostic challenge. APSP J Case Rep. 2011;2(2):19. [PMC free article] [PubMed] [Google Scholar]
- 5.Rybojad B, Niedzielska G, Niedzielski A, Rudnicka-Drozak E, Rybojad P. Esophageal foreign bodies in pediatric patients: a thirteen-year retrospective study. Scientific World J. 2012;2012:102642. doi: 10.1100/2012/102642. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.ASGE Standards of Practice Committee Management of ingested foreign bodies and food impactions. Gastrointest Endosc. 2011;73(6):1085–1091. doi: 10.1016/j.gie.2010.11.010. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable