Abstract
We introduce a new type of multi-functional capacitive sensor that can sense several different external stimuli. It is fabricated only with polydimethylsiloxane (PDMS) films and silver nanowire electrodes by using selective oxygen plasma treatment method without photolithography and etching processes. Differently from the conventional single-capacitor multi-functional sensors, our new multi-functional sensor is composed of two vertically-stacked capacitors (dual-capacitor). The unique dual-capacitor structure can detect the type and strength of external stimuli including curvature, pressure, strain, and touch with clear distinction, and it can also detect the surface-normal directionality of curvature, pressure, and touch. Meanwhile, the conventional single-capacitor sensor has ambiguity in distinguishing curvature and pressure and it can detect only the strength of external stimulus. The type, directionality, and strength of external stimulus can be determined based on the relative capacitance changes of the two stacked capacitors. Additionally, the logical flow reflected on a tree structure with its branches reaching the direction and strength of the corresponding external stimulus unambiguously is devised. This logical flow can be readily implemented in the sensor driving circuit if the dual-capacitor sensor is commercialized actually in the future.
Introduction
Due to the increasing demand for human-machine interface devices used in robotics1–3, internet of things (IoT)4, 5, and personal healthcare monitoring systems6–10, the performances and functionalities of associated sensors are required to be enhanced accordingly11–18. In human-machine interface systems, sensors play crucial roles in conceiving signals from human, such as bioelectrical signals in electroencephalogram (EEG)19–23 and electrocardiogram (ECG)23–26 and body motions11, 27–33, and then delivering them to machine correctly. With the aids of sensors, a machine can acquire several sensing capabilities like human and also be controlled properly by the conceived signals34. For sophisticated sensing, sensors should be able to detect and distinguish several different signals (Multi-functionality). Also, stretchability is an essential property needed especially for attaching sensors to skin or clothes35–40.
Recently, many groups have studied skin-mountable multi-functional capacitive sensors by using various materials. The Zhu’s group reported a wearable multi-functional sensor based on silver nanowire (AgNW), which could detect strain, pressure, finger touch, and various human motions such as walking, running, squatting, and jumping16. The Lacour’s group also introduced a stretchable multi-functional sensor made of gold thin films embedded in polydimethylsiloxane (PDMS) which could detect strain, pressure, and finger touch14. However, all former researches are based on single-capacitor sensors which have some inevitable limitations. Firstly, they can detect only the magnitude of stimulus with no information about direction. Secondly, it is not possible to distinguish the types of detected stimuli quite clearly just based on the capacitance change of single capacitor. For example, single-capacitor sensors show the similar capacitance increase for pressure and strain applied on them. In this work, we introduce a new type of dual-capacitor multi-functional sensor to overcome the limitations of the sensors developed so far. Unlike the aforementioned single-capacitor sensor, our dual-capacitor sensor consists of two vertically stacked capacitors in each pixel so that it can classify the type of external stimulus unambiguously and also can detect its strength and surface-normal directionality. These features of our dual-capacitor sensor are confirmed for curvature, pressure, touch, and strain sensing.
Results
Non-lithographic fabrication processes of dual-capacitor sensor
Figure 1a illustrates the fabrication processes of dual-capacitor multi-functional sensor in 5 × 5 array form. More detailed descriptions for the fabrication processes can be found in experimental section. Basically, the whole sensor was fabricated just by using AgNW and PDMS. The substrate, lower dielectric layer, upper dielectric layer, and protective layer were formed with PDMS films while all the electrodes including bottom, middle, and top ones were made by patterning spin-coated AgNW films. Those three electrodes separated from one another by dielectric layers were patterned by using selective oxygen (O2) plasma treatment method (See Supplementary Information Fig. S1) to have their line-width of ~2 mm and line-spacing also of ~2 mm41. Our selective oxygen plasma treatment method has uniqueness in the sense that it enables patterning AgNW electrodes without using photolithography and etching processes. The thickness of lower and upper insulating layers was ~400 μm commonly. Differently from the previous studies where two PDMS films with line-pattern AgNW electrodes on their surfaces were attached physically to each other for forming a pixelated single-capacitor sensor11, 16, 17, all the layers of our dual-capacitor sensor were deposited sequentially, starting from the substrate, which makes it easy to control the thickness of PDMS film and align the two stacked capacitors precisely, and is also advantageous to secure the solid adhesion between stacked layers. The sequential stacking of PDMS layers was achieved by spin-coating liquid PDMS on the surface of hardened underlying PDMS layer with patterned AgNW electrodes and curing it in an oven. The details of curing process are described in “Methods” section below. After curing, the liquid PDMS was found to be firmly bonded to the underlying PDMS layer, implying the excellent adhesion between the PDMS layers at the interface. The cross-sectional optical microscope image of strongly bonded PDMS stacks is shown in Fig. S3 of Supplementary Information. The average measured capacitance of each capacitor in the whole 25 pixels was ~2.2 pF. Figure 1b shows the schematic view of completed dual-capacitor sensor when it is bent into convex with the curvature radius of r(θ). θ is the corresponding curvature angle. Figure 1c and d are the photographic images of the completed sensor, demonstrating its flexible and stretchable properties.
Curvature sensing
Initially, the lateral sizes (L 0 and W 0) and dielectric layer thicknesses (d 0) of the two parallel-plate capacitors of dual-capacitor sensor are the same as each other. When the dual-capacitor is curved as shown in Fig. 1b (convex), the top electrode (W 3(θ)) will be stretched more than the middle electrode (W 2(θ)). Meanwhile, the bottom electrode will have almost no stretching (W 1(θ) ≈ W 0). Here, it is noted that the PDMS elastomer with its Poisson ratio of nearly 0.5 is known to be incompressible for plastic deformation at relatively small strain and hence the bottom electrode will not be compressed with the plastic bending for curvature sensing14, 42, 43. By considering the formula of cylindrical capacitor, the capacitances of lower (C 1) and upper (C 2) capacitors can be represented as the following relations.
1 |
Here, ε 0 is vacuum permittivity and ε r the dielectric constant of dielectric layer. If the dual-capacitor is curved to be concave, the same form of relations will be obtained but this time, C 1 and C 2 will be exchanged mutually. The detailed derivation procedures of equation (1) are described in “Methods” section. Figure 2a and b show the capacitance changes of the lower (ΔC 1) and upper (ΔC 2) capacitors as functions of the curvature 1/r. As predicted in equation (1) and the associated statements, C 1 and C 2 increase monotonically. In case of the convex shape (Fig. 2a), ΔC 2 is larger than ΔC 1 for the entire curvature range. On the other hand, ΔC 2 is smaller than ΔC 1 for the concave shape (Fig. 2b). In Fig. 2c, the difference between ΔC 1 and ΔC 2 is plotted also as a function of 1/r where the difference is found to increase with the curvature increasing. From these measured data, it is clear that our dual-capacitor sensor can detect the surface-normal directionality and radius of curvature by comparing ΔC 1 and ΔC 2 with proper calibration.
Pressure sensing
Similarly to the curvature sensing, our dual-capacitor sensor can conceive both the magnitude and the surface-normal directionality of pressure given to it by measuring ΔC 1 and ΔC 2. Again, in order to determine the magnitude of pressure correctly, the proper calibration connecting the measured capacitance change and the magnitude of pressure needs to be done. When the dual-capacitor sensor is pressed locally with a certain magnitude of force from either upper or lower side (let’s say from the upper side for the following discussion), the applied force will be dispersed sideway more and more as going down through the insulator layer of upper capacitor. Accordingly, the pressure defined as force divided by area will become smaller and smaller as going into the insulator layer. If the insulator of upper capacitor is thick enough, the pressure at the depth of lower capacitor will be reduced significantly. Then, only the insulator of upper capacitor will be compressed while that of lower capacitor is hardly compressed. So to speak, the applied pressure is absorbed almost entirely by the capacitor on the side of the pressure being applied. More concretely, the ~400 μm thick PDMS layer is found to absorb the pressure completely up to ~75 kPa which is the largest pressure used in our experiments. Consequently, only one of the two capacitors will be compressed and its capacitance will increase while the other will hardly change in its shape and capacitance as shown in Fig. 3a. Figure 3d shows the capacitance changes of each capacitor in the dual-capacitor sensor as a function of applied pressure. As expected, only ΔC 2 increases with almost no change of ΔC 1 when the pressure is applied onto the upper side of sensor. For the pressures below 10 kPa, ΔC 2 increases somewhat rapidly and the increase slows down as the pressure becomes further larger. The pressure sensitivity (S) is defined to be the slope of the curve plotting the capacitance change ratio depending on pressure as shown below44.
2 |
Here, p is the applied pressure, C 0 the initial capacitance with no pressure applied, and ΔC the capacitance change referenced from C 0. For the pressures above 10 kPa, ΔC 2 increases more gradually in a linear fashion. The pressure sensitivity in this regime is estimated to be ~1 MPa−1 which is higher than other studies using PDMS as an insulating layer14. It is considered that the very thin protective layer is the main contributor for high pressure sensitivity which can transfer the applied pressure to the buried capacitor with minimal loss.
Strain sensing
When the dual-capacitor sensor is stretched out sideway, the thicknesses of two insulating layers will decrease ideally by the same amount and both capacitances, C 1 and C 2, will increase accordingly (Fig. 3b). Figure 3e shows ΔC 1 and ΔC 2 as the strain of sensor increases. Both of them are almost identical to each other and increases linearly up to the strain of 25%. The stability of our dual-capacitor sensor for multiple stretching was confirmed by the stretching and releasing cycle test increased up to 1000 repetitions as shown in Fig. S4. The capacitance of dual-capacitor sensor returned back to its initial value without residual strain after being released from stretching.
Touch sensing
In case of touch sensing, the redistribution of fringing electric field lines causes the change of measured capacitance45, unlike curvature, pressure, and strain sensing for which the capacitance change occurs due to structural deformation. When a finger (or a grounded conductive object) touches the top surface of sensor, some of the fringing electric field lines residing in the insulating layers of two capacitors will be absorbed by the finger. The decreases of fringing electric field lines in the insulating layers are equivalent to reducing the dielectric constants of the insulating layers effectively, resulting in the decreases of measured capacitances. Figure 3c illustrates the distribution of fringing electric field lines with the finger touch on the top surface of sensor. As shown in the figure, the upper capacitor right near the finger will lose more fringing electric field lines to the finger than the lower one. Hence, the capacitance of the upper capacitor will decrease more. These expectations match exactly with the actual measurements (Fig. 3f). When the finger touches on the top side of sensor, ΔC 2 is ~19.0% of the capacitance without touch, larger than ΔC 1 of ~15.5%. These measured touch sensitivities are better than other reported values and we believe that the high touch sensitivities are also due to the relatively thin protective layer in comparison with other studies16, 17. The distance between touching finger and buried sensor becomes shorter as the protective layer gets thinner so that more fringing electric fields can be absorbed by the finger, leading to larger capacitance decrease and higher touch sensitivity eventually.
Unambiguous classification of the external stimuli given to dual-capacitor sensor
So far, we have demonstrated that our dual-capacitor sensor can detect curvature, pressure, strain, and touch altogether. Then, one question raised naturally is whether or not those sensing modes can be distinguished clearly from one another. This is a crucial capability for the dual-capacitor sensor to be used as a multi-sensor in actuality. As discussed previously and listed in Table 1, ΔC 1 and ΔC 2 have a unique combination for each sensing mode in terms of their signs and magnitudes. For instance, ΔC 1 and ΔC 2 will be positive and one of them will be larger in magnitude than the other when the sensor is bent (Curvature sensing). Meanwhile both of them will be negative when the sensor gets just touched. Figure 4 shows the logical flow to determine what kind of physical stimulus is applied to the sensor, based on the measured capacitance changes of dual-capacitor sensor. As seen in the figure, there is no ambiguity in classifying the applied physical stimulus into curvature, pressure, strain, or touch.
Table 1.
Sensing mode | Direction | Lower capacitor (C1) | Upper capacitor (C2) | ∆C1 vs. ∆C2 |
---|---|---|---|---|
Curvature | convex | ∆C1 > 0 | ∆C2 > 0 | ∆C1 < ∆C2 |
concave | ∆C1 > 0 | ∆C2 > 0 | ∆C1 > ∆C2 | |
Pressure | upper side | ∆C1 = 0 | ∆C2 > 0 | ∆C1 < ∆C2 |
lower side | ∆C1 > 0 | ∆C2 = 0 | ∆C1 > ∆C2 | |
Touch | upper side | ∆C1 < 0 | ∆C2 < 0 | |∆C1| < |∆C2| |
lower side | ∆C1 < 0 | ∆C2 < 0 | |∆C1| > |∆C2| | |
Strain | uniaxial | ∆C1 > 0 | ∆C2 > 0 | ∆C1 = ∆C2 |
The relative relations of upper (ΔC 2) and lower (ΔC 1) capacitance changes of the two capacitors in dual-capacitor sensor are uniquely distinguishable for curvature, pressure, strain, and touch sensing.
Discussion
In conclusion, we fabricated the 5 × 5 array type of stretchable multifunctional dual-capacitor sensor, based on AgNW electrodes and PDMS insulators. Differently from other reported capacitive sensors, our dual-capacitor sensor is composed of two vertically-stacked capacitors. With the two capacitors, the sensor is capable of sensing both strength and surface-normal directionality of several physical stimuli including curvature, pressure, strain, and touch. In addition, it is confirmed that the dual-capacitor sensor can classify the physical stimulus given to it unambiguously into one of curvature, pressure, strain, and touch by comparing the capacitance changes of the two capacitors and following the logical flow designed properly. It is quite certain that our dual-capacitor sensor can enrich the information communicated in the human-machine interface. Thus, the dual-capacitor sensor is expected to be used quite extensively in various applications such as robotics, healthcare monitoring systems, and internet of things (IoT).
Methods
Formation of PDMS film
A PDMS (Sylgard 184, Dow Corning) film was formed by mixing the “base” and the “curing agent” with the weight ratio of 10: 1 and stirring the mixture for 5 minutes. Then, the PDMS film was stored at −4 °C for one day to remove the air bubbles residing in the film. The thickness of PDMS film was controlled easily by adjusting spin-coating speed and time. As the last step, the PDMS film free of air bubbles was cured in an oven at 100 °C for 20 minutes for hardening.
Patterning of AgNW electrodes and contact pads
Before AgNW (0.3 wt.% of AgNW dispersed in distilled water) coating, the surface of PDMS film was activated by oxygen (O2) plasma treatment to convert the surface property from hydrophobic to hydrophilic, which improves the adhesion of AgNW dispersed on the PDMS surface. The O2 plasma treatment was performed with 100 W power for 5 minutes by using reactive ion etching (RIE, TTL Korea). In this step, we activated the PDMS surface selectively by using a shadow mask as shown in Fig. S1. With the selective activation, the AgNW electrodes could be patterned simultaneously while spin-coating the AgNW solution with no need of photolithography and etching processes. After that, we baked the sample at 110 °C for 10 minutes to remove the distilled water and leave the patterned AgNW electrodes only. Finally, the contact pads were formed by evaporating Ti (10 nm) and Au (50 nm) sequentially through another shadow mask.
Methods of applying external stimuli
The pressure was applied by loading rectangular acrylic blocks on the dual-capacitor sensor and its magnitude was controlled by varying the number of acrylic blocks. The radius of curvature was adjusted by changing the distance between the two acrylic clamping jigs holding both ends of sensor as shown in Fig. 1c. The tensile strain was achieved by pulling both ends of sensor in the opposite directions with the two clamping jigs. Finally, the touch was done by landing the finger gently on the surface of sensor and minimizing the force exerted on it.
Capacitance measurements
The capacitance of the dual-capacitor sensor was measured by using the Precision LCR meter (E4980A, Agilent) at the frequency of 1 MHz with a 50 mV dithering voltage controlled by our own LabView program. The LCR meter is not capable of measuring two capacitances simultaneously and hence the capacitances of the upper and lower capacitors had to be measured separately while maintaining the external stimulus given to the dual-capacitor sensor. For example, in case of curvature sensing, the capacitances of the upper and lower capacitors were measured sequentially without changing the curved shape of the sensor. The time-varying plots of the capacitance changes in touch sensing shown in Fig. 3f were obtained in the following ways: First, the capacitance change of the upper (or lower) capacitor was measured as a function of time while the touch and untouch motions were being done periodically with specified time intervals. Then, the capacitance change of the other capacitor was measured with the same time-sequential touch and untouch motions as the ones in the previous measurements. In the end, the time-varying capacitance changes of the upper and lower capacitors were plotted together in a single graph.
Capacitances of two capacitors for dual-capacitor sensor under curvature (convex)
When the dual-capacitor is bent as shown in Fig. 1b, the capacitances of two capacitors are given as follows.
3 |
If assuming that the cross-sectional areas of dielectric layers are the same as those with the dual-capacitor sensor in its initial state (No bending), the following relations can be obtained for the thicknesses of dielectric layers.
4 |
By plugging equation (4) into equation (3), the capacitances of two capacitors can be further simplified to be expressed just with the curvature radius r(θ).
5 |
Electronic supplementary material
Acknowledgements
This work was supported by National Nuclear R&D Program (2014M2B2A9031944), Space Core Technology Development Program (2016M1A3A3A02017648), and Basic Science Research Program (2016R1A2B4014762) through the National Research Foundation funded by the Ministry of Science, ICT, and Future Planning in Korea and the university-industry cooperation program partnered with Samsung Display and the university-industry cooperation program partnered with Samsung Display. This work has also benefited from the use of the facilities at UNIST Central Research Facilities.
Author Contributions
H.J. and K.P. conceived and designed the project. H.J., S.J., and J.K. fabricated dual-capacitor sensors. H.J., S.J., and J.K. performed the structural and electrical characterization for analyzing the sensing capabilities of the fabricated devices. H.J., S.J., J.K., S.H., F.B., and K.P. analyzed the measured data. H.J, S.J., J.K., S.H., J.L., W.P., H.Y.C., F.B., and K.P. discussed the results and wrote the paper.
Competing Interests
The authors declare that they have no competing interests.
Footnotes
Electronic supplementary material
Supplementary information accompanies this paper at doi:10.1038/s41598-017-11217-w
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Franklin Bien, Email: bien@unist.ac.kr.
Kibog Park, Email: kibogpark@unist.ac.kr.
References
- 1.Saudabayev A, Varol HA. Sensors for robotic hands: a survey of state of the art. IEEE Access. 2015;3:1765–1782. doi: 10.1109/ACCESS.2015.2482543. [DOI] [Google Scholar]
- 2.Lu N, Kim D-H. Flexible and stretchable electronics paving the way for soft robotics. Soft Robot. 2014;1:53–62. doi: 10.1089/soro.2013.0005. [DOI] [Google Scholar]
- 3.Atzori, M. et al. Electromyography data for non-invasive naturally-controlled robotic hand prostheses. Sci. Data1 (2014). [DOI] [PMC free article] [PubMed]
- 4.Gubbi J, Buyya R, Marusic S, Palaniswami M. Internet of Things (IoT): A vision, architectural elements, and future directions. Future Gen. Comput. Syst. 2013;29:1645–1660. doi: 10.1016/j.future.2013.01.010. [DOI] [Google Scholar]
- 5.Atzori L, Iera A, Morabito G. The internet of things: A survey. Comput. Netw. 2010;54:2787–2805. doi: 10.1016/j.comnet.2010.05.010. [DOI] [Google Scholar]
- 6.Pantelopoulos A, Bourbakis NG. A survey on wearable sensor-based systems for health monitoring and prognosis. IEEE Trans. Syst. Man Cybern. Part C-Appl. Rev. 2010;40:1–12. doi: 10.1109/TSMCC.2009.2032660. [DOI] [Google Scholar]
- 7.Potyrailo RA. Multivariable sensors for ubiquitous monitoring of gases in the era of internet of things and industrial internet. Chem. Rev. 2016;116:11877–11923. doi: 10.1021/acs.chemrev.6b00187. [DOI] [PubMed] [Google Scholar]
- 8.Teng X-F, Zhang Y-T, Poon CC, Bonato P. Wearable medical systems for p-health. IEEE Rev. Biomed. Eng. 2008;1:62–74. doi: 10.1109/RBME.2008.2008248. [DOI] [PubMed] [Google Scholar]
- 9.Gatzoulis L, Iakovidis I. Wearable and portable eHealth systems. IEEE Eng. Med. Biol. Mag. 2007;26:51–56. doi: 10.1109/EMB.2007.901787. [DOI] [PubMed] [Google Scholar]
- 10.Schwartz G, et al. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring. Nature commun. 2013;4:1859. doi: 10.1038/ncomms2832. [DOI] [PubMed] [Google Scholar]
- 11.Lipomi DJ, et al. Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes. Nature nanotech. 2011;6:788–792. doi: 10.1038/nnano.2011.184. [DOI] [PubMed] [Google Scholar]
- 12.Son D, et al. Multifunctional wearable devices for diagnosis and therapy of movement disorders. Nature nanotech. 2014;9:397–404. doi: 10.1038/nnano.2014.38. [DOI] [PubMed] [Google Scholar]
- 13.Pandey S, Nanda KK. Au Nanocomposite based chemiresistive ammonia sensor for health monitoring. ACS Sens. 2016;1:55–62. doi: 10.1021/acssensors.5b00013. [DOI] [Google Scholar]
- 14.Cotton DP, Graz IM, Lacour SP. A multifunctional capacitive sensor for stretchable electronic skins. IEEE Sens. J. 2009;9:2008–2009. doi: 10.1109/JSEN.2009.2030709. [DOI] [Google Scholar]
- 15.Luo S, Liu T. Graphite nanoplatelet enabled embeddable fiber sensor for in situ curing monitoring and structural health monitoring of polymeric composites. ACS Appl. Mater. Interfaces. 2014;6:9314–9320. doi: 10.1021/am5017039. [DOI] [PubMed] [Google Scholar]
- 16.Yao S, Zhu Y. Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires. Nanoscale. 2014;6:2345–2352. doi: 10.1039/c3nr05496a. [DOI] [PubMed] [Google Scholar]
- 17.Hu W, Niu X, Zhao R, Pei Q. Elastomeric transparent capacitive sensors based on an interpenetrating composite of silver nanowires and polyurethane. Appl. Phys. Lett. 2013;102:083303. doi: 10.1063/1.4794143. [DOI] [Google Scholar]
- 18.Kim, J. et al. Stretchable silicon nanoribbon electronics for skin prosthesis. Nature commun. 5 (2014). [DOI] [PubMed]
- 19.Hairston WD, et al. Usability of four commercially-oriented EEG systems. J. Neural Eng. 2014;11:046018. doi: 10.1088/1741-2560/11/4/046018. [DOI] [PubMed] [Google Scholar]
- 20.Harland C, Clark T, Prance R. Remote detection of human electroencephalograms using ultrahigh input impedance electric potential sensors. Appl. Phys. Lett. 2002;81:3284–3286. doi: 10.1063/1.1516861. [DOI] [Google Scholar]
- 21.Lopez-Gordo M, Sanchez-Morillo D, Valle FP. Dry EEG electrodes. Sensors. 2014;14:12847–12870. doi: 10.3390/s140712847. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Alizadeh-Taheri B, Smith RL, Knight RT. An active, microfabricated, scalp electrode array for EEG recording. Sens. Actuators A: Phys. 1996;54:606–611. doi: 10.1016/S0924-4247(97)80023-4. [DOI] [Google Scholar]
- 23.Salvo P, et al. A 3D printed dry electrode for ECG/EEG recording. Sens. Actuators A, Phys. 2012;174:96–102. doi: 10.1016/j.sna.2011.12.017. [DOI] [Google Scholar]
- 24.Paradiso R, Loriga G, Taccini N. A wearable health care system based on knitted integrated sensors. IEEE Trans. Inf. Technol. Biomed. 2005;9:337–344. doi: 10.1109/TITB.2005.854512. [DOI] [PubMed] [Google Scholar]
- 25.Myers AC, Huang H, Zhu Y. Wearable silver nanowire dry electrodes for electrophysiological sensing. RSC Adv. 2015;5:11627–11632. doi: 10.1039/C4RA15101A. [DOI] [Google Scholar]
- 26.Kim T, Park J, Sohn J, Cho D, Jeon S. Bioinspired, highly stretchable, and conductive dry adhesives based on 1D–2D hybrid carbon nanocomposites for all-in-one ECG electrodes. ACS Nano. 2016;10:4770–4778. doi: 10.1021/acsnano.6b01355. [DOI] [PubMed] [Google Scholar]
- 27.Yamada T, et al. A stretchable carbon nanotube strain sensor for human-motion detection. Nature nanotech. 2011;6:296–301. doi: 10.1038/nnano.2011.36. [DOI] [PubMed] [Google Scholar]
- 28.Cai, L. et al. Super-stretchable, transparent carbon nanotube-based capacitive strain sensors for human motion detection. Sci. Rep. 3 (2013). [DOI] [PMC free article] [PubMed]
- 29.Amjadi M, Pichitpajongkit A, Lee S, Ryu S, Park I. Highly stretchable and sensitive strain sensor based on silver nanowire–elastomer nanocomposite. ACS nano. 2014;8:5154–5163. doi: 10.1021/nn501204t. [DOI] [PubMed] [Google Scholar]
- 30.Ryu S, et al. Extremely elastic wearable carbon nanotube fiber strain sensor for monitoring of human motion. ACS Nano. 2015;9:5929–5936. doi: 10.1021/acsnano.5b00599. [DOI] [PubMed] [Google Scholar]
- 31.Wu X, Han Y, Zhang X, Lu C. Highly sensitive, stretchable, and wash-durable strain sensor based on ultrathin conductive layer@polyurethane yarn for tiny motion monitoring. ACS Appl. Mater. Interfaces. 2016;8:9936–9945. doi: 10.1021/acsami.6b01174. [DOI] [PubMed] [Google Scholar]
- 32.Wang Z, et al. Polyurethane/cotton/carbon nanotubes core-spun yarn as high reliability stretchable strain sensor for human motion detection. ACS Appl. Mater. Interfaces. 2016;8:24837–24843. doi: 10.1021/acsami.6b08207. [DOI] [PubMed] [Google Scholar]
- 33.Suzuki K, et al. Rapid-response, widely stretchable sensor of aligned MWCNT/elastomer composites for human motion detection. ACS Sens. 2016;1:817–825. doi: 10.1021/acssensors.6b00145. [DOI] [Google Scholar]
- 34.Raspopovic, S. et al. Restoring natural sensory feedback in real-time bidirectional hand prostheses. Sci. transl. med. 6, 222ra219 (2014). [DOI] [PubMed]
- 35.Zhao X, Hua Q, Yu R, Zhang Y, Pan C. Flexible, stretchable and wearable multifunctional sensor array as artificial electronic skin for static and dynamic strain mapping. Adv. Electron. Mater. 2015;1:1500142. doi: 10.1002/aelm.201500142. [DOI] [Google Scholar]
- 36.Jeong YR, et al. Highly stretchable and sensitive strain sensors using fragmentized graphene foam. Adv. Funct. Mater. 2015;25:4228–4236. doi: 10.1002/adfm.201501000. [DOI] [Google Scholar]
- 37.Rahimi R, Ochoa M, Yu W, Ziaie B. Highly stretchable and sensitive unidirectional strain sensor via laser carbonization. ACS Appl. Mater. Interfaces. 2015;7:4463–4470. doi: 10.1021/am509087u. [DOI] [PubMed] [Google Scholar]
- 38.Cheng Y, Wang R, Sun J, Gao L. A Stretchable and highly sensitive graphene-based fiber for sensing tensile strain, bending, and torsion. Adv. Mater. 2015;27:7365–7371. doi: 10.1002/adma.201503558. [DOI] [PubMed] [Google Scholar]
- 39.Roh E, Hwang B-U, Kim D, Kim B-Y, Lee N-E. Stretchable, transparent, ultrasensitive, and patchable strain sensor for human–machine interfaces comprising a nanohybrid of carbon nanotubes and conductive elastomers. ACS Nano. 2015;9:6252–6261. doi: 10.1021/acsnano.5b01613. [DOI] [PubMed] [Google Scholar]
- 40.Morteza A, Yong Jin Y, Inkyu P. Ultra-stretchable and skin-mountable strain sensors using carbon nanotubes–Ecoflex nanocomposites. Nanotechnology. 2015;26:375501. doi: 10.1088/0957-4484/26/37/375501. [DOI] [PubMed] [Google Scholar]
- 41.Chen W, Lam RH, Fu J. Photolithographic surface micromachining of polydimethylsiloxane (PDMS) Lab Chip. 2012;12:391–395. doi: 10.1039/C1LC20721K. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Larmagnac A, Eggenberger S, Janossy H, Vörös J. Stretchable electronics based on Ag-PDMS composites. Sci. Rep. 2014;4:7254. doi: 10.1038/srep07254. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Yu Y-S, Zhao Y-P. Deformation of PDMS membrane and microcantilever by a water droplet: Comparison between Mooney–Rivlin and linear elastic constitutive models. J. Colloid Interface Sci. 2009;332:467–476. doi: 10.1016/j.jcis.2008.12.054. [DOI] [PubMed] [Google Scholar]
- 44.Mannsfeld SC, et al. Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nature mater. 2010;9:859–864. doi: 10.1038/nmat2834. [DOI] [PubMed] [Google Scholar]
- 45.Lee J, Cole MT, Lai JCS, Nathan A. An analysis of electrode patterns in capacitive touch screen panels. J. Display Technol. 2014;10:362–366. doi: 10.1109/JDT.2014.2303980. [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.