Abstract
Purpose
To present the most updated American College of Radiology (ACR) Appropriateness Criteria formed by an expert panel on the appropriate delivery of external beam radiation to manage stage T1 and T2 prostate cancer (in the definitive setting and post-prostatectomy) and to provide clinical variants with expert recommendations based on accompanying Appropriateness Criteria for target volumes and treatment planning.
Methods and materials
The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a panel of multidisciplinary experts. The guideline development and revision process includes an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In instances in which evidence is lacking or equivocal, expert opinion may supplement available evidence to recommend imaging or treatment.
Results
The panel summarizes the most recent and relevant literature on the topic, including organ motion and localization methods, image guidance, and delivery techniques (eg, 3-dimensional conformal intensity modulation). The panel presents 7 clinical variants, including (1) a standard case and cases with (2) a distended rectum, (3) a large-volume prostate, (4) bilateral hip implants, (5) inflammatory bowel disease, (6) prior prostatectomy, and (7) a pannus extending into the radiation field. Each case outlines the appropriate techniques for simulation, treatment planning, image guidance, dose, and fractionation. Numerical rating and commentary is given for each treatment approach in each variant.
Conclusions
External beam radiation is a key component of the curative management of T1 and T2 prostate cancer. By combining the most recent medical literature, these Appropriateness Criteria can aid clinicians in determining the appropriate treatment delivery and personalized approaches for individual patients.
Introduction
This review complements other American College of Radiology (ACR) Appropriateness Criteria for localized prostate cancer by focusing on the practical and technical elements of external beam radiation therapy (EBRT).1, 2 This document provides guidance for EBRT treatment planning for localized, organ-confined prostate cancer; locally advanced node-negative disease; and post-prostatectomy radiation therapy (RT). Part II covers treatment delivery: organ motion, target localization, image guidance, and RT delivery techniques. Additionally, clinical variants are presented (see Variant 1, Variant 2, Variant 3, Variant 4, Variant 5, Variant 6, Variant 7).
RT fractionation definitions
This article relates mostly to men who are treated with dose-escalated conventionally fractionated EBRT (CFRT; a single 1.8-2.0 Gy fraction delivered in approximately 15 minutes per day, 5 days per week for 8-9 weeks, to a total dose of 76-80 Gy), which is an established treatment modality for men in all disease risk groups. Other fractionation techniques to treat patients with prostate cancer exist. For example, moderately hypofractionated RT (HFRT; 2.1-3.5 Gy per fraction for approximately 15 minutes per day, 5 days per week for approximately 4 weeks, to a total dose of approximately 52-72 Gy) has been tested in phase I-III trials since the 1990s.3 Extremely fractionated RT, also termed stereotactic body RT (SBRT; 3.5-15 Gy per fraction in 5 fractions or less), is an emerging form of EBRT that, to date, has mostly been reserved for patients with low-risk prostate cancer.4 HFRT and SBRT deliver a higher dose per fraction to the prostate; thus, these methods also require diligence in treatment planning.
Organ motion and target localization methods
Prostate motion: Interfractional
Between fractions of conventionally fractionated EBRT, the prostate has been estimated to have translational and rotational movements. With respect to translational movements, Beltran et al5 determined the necessary planning target volume (PTV) margins on the basis of the intrafractional motion (which gives rise to internal margin) and interfractional motion (which gives rise to the setup margin) for 4 daily localization methods: skin marks with tattoos, pelvic bony anatomy, intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. With tattoo localization, there is a setup error of 6.8 mm in the left–right axis, 7.2 mm in the superior–inferior axis, and 9.8 mm in the anterior-posterior (AP) axis. Bone localization requires 3.1, 8.9, and 10.7 mm in each axis, respectively. The intraprostatic gold seed using a 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm margins, respectively. No-threshold localization requires 3.4, 3.2, and 3.2 mm.5 Wong et al6 evaluated interfraction prostate shifts on 1870 computed tomography (CT) on rails images from 329 patients treated with EBRT. They noted that the greatest interfractional motion was in the AP axis.
In addition, the prostate rotates between fractions. Graf et al7 quantified the rotation of the prostate using kV x-ray imaging and intraprostatic fiducials. They reported that the rotation in the plane of the treatment table, in superior–inferior direction (ie, roll), and the left–right axis (ie, tilt/pitch) are on average 0.09°, −0.52°, and −0.01° with standard deviations of 2.01°, 2.30°, and 3.95°, respectively. The largest rotational errors occurred around the left–right axis but without preference for a certain orientation.
Prostate motion: Intrafractional
During a fraction of conventionally fractionated EBRT, the prostate has also been noted to have translational and rotational movements. Beltran et al5 reported that the intrafractional prostate motion requires a setup margin of 2.4 mm in the left–right axis and 3.4 mm in the inferior–superior and AP axes. From their data on interfractional motion, the researchers concluded that localizing on the bony anatomy leads to an increase in the required margins compared with simple tattoo localization. Thus, they recommended that the PTV margin, including the intrafraction motion, interfraction motion, and interobserver uncertainty, needed for a 5 mm action threshold (ie, if a displacement of <5 mm is noted, then the displacement is recorded but a couch shift is not made) is 4.8 mm in the left–right direction, 5.4 mm in the inferior–superior direction, and 5.2 mm in the AP direction.5
With respect to intrafractional rotational movements, Badakhshi et al8 reported that during a 14-minute fraction, the standard deviations of intrafractional rotation errors of the prostate around the superior–inferior and left–right axes were 2.2° and 3.6° on average, respectively. Margins that covered the intrafractional motion were 4.5 and 4.3 mm in the superior–inferior and AP axes without intrafractional correction. If they applied rotation correction above a threshold of 1° of displacement, the margins were 2.9 mm and 2.8 mm in the superior–inferior and AP axes, respectively.8
As the EBRT time increases, the risk of significant intrafraction prostate motion increases. Cramer et al9 evaluated intrafraction prostate motion during intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) using electromagnetic transponders and recommended patient repositioning when treatment duration exceeds 4 to 6 minutes. Shelton et al10 observed a similar relationship between treatment duration and intrafraction prostate motion, with shorter treatment times achieved with VMAT (compared with IMRT), which resulted in a 30% to 40% reduction in intrafraction prostate motion.
Seminal vesicles and lymph nodes
Seminal vesicles (SVs) can move during the delivery of a fraction of prostate EBRT, with a strong correlation to rectal volume.11 SV movement during and between fractions is independent of the prostate and with respect to the contralateral SV. Thus, when the SVs are in the treatment volume, their interfractional motion must also be taken into account.
Gill et al3 performed cinematic magnetic resonance imaging (MRI) for 11 patients undergoing RT to assess intrafraction SV motion. They reported displacements between the 2.5th percentile and 97.5th percentile (ie, 2.5% trimmed range) of the prostate and SV centroids at different time points. At 3, 5, 10, and 15 minutes, the SV centroid measured 4.7, 5.8, 6.5, and 7.2 mm in the superior–inferior direction, respectively. In the AP direction, it was 4.0, 4.5, 6.5, and 7.0 mm, respectively. In the left–right direction for 3, 5, and 10 minutes, the left SV was 2.7, 2.8, and 3.4 mm, respectively; for the right SV, it was 3.4, 3.3, and 3.4 mm, respectively. Thus, the motion of the SVs increases with time, and the prostate and SV centroids do not move in unison in real time.
With respect to SV interfraction motion, Frank et al4 used serial pretreatment CT scans and demonstrated that the mean 3-dimensional vector displacement was 4.6 mm for the prostate and 7.6 mm for the SVs. Similarly, Liang et al12 studied SV interfraction motion and found that minimum margins of 3 mm for the prostate and 4.5 mm for SVs were required for IMRT.
Adamczyk et al13 performed a retrospective analysis of 253 cone beam CT (CBCT) studies of 28 patients to estimate the interfraction corrections on doses delivered to the prostate, SVs, and lymph nodes (LNs) and to determine the ideal PTVs to these targets with prostate-based position verification. They recommended margin sizes of 0.7 cm for the prostate, 0.8 to 0.9 cm for the SVs, and asymmetric 1.0 cm (vertically) and 0.5 cm (other axes) for the LNs.13
Prostate bed
The prostate bed also has interfraction and intrafraction motion. In a prospective study of 14 patients undergoing adjuvant or salvage RT to the prostate bed, Huang et al14 assessed the uncertainty and motion by offline analysis using 3 consecutive daily kV CBCT images of each patient: (1) after initial setup to skin marks, (2) after correction for positional error/immediately before radiation treatment, and (3) immediately after treatment. They reported that the magnitude of interfraction prostate bed motion was 2.1 mm and intrafraction prostate bed motion was 0.4 mm. The maximum interfraction and intrafraction prostate bed motion was primarily in the AP direction. The authors recommended margins of at least 3 to 5 mm with image guidance and 4 to 7 mm without image guidance (ie, aligning to skin marks) to ensure 95% of the prescribed dose to the clinical target volume (CTV) in 90% of patients.14
In a similar analysis, Klayton et al15 assessed prostate bed motion using radiofrequency transponders in 2 patients undergoing IMRT. At localization, prostate bed displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the AP direction and 21% of fractions in the superior–inferior direction. During treatment, the target exceeded the 5-mm tracking limit for at least 30 seconds in 11% of all fractions, generally in the AP or superior–inferior directions. In the AP direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly.15
Methods for image guided radiation therapy
The delivery of a high radiation dose to obtain tumor control is limited by the tolerance of the adjacent normal organs. Moreover, prostate movement can occur and influence dosimetric coverage. Prostate movements occur both between and within fractions of delivery; the movements are translational, rotational, and deformational.16 In theory, image guided radiation therapy (IGRT) devices maximize the dose delivered to the tumor to improve patient outcomes and minimize the dose delivered to surrounding critical structures to decrease gastrointestinal and genitourinary toxicity. In practice, however, the use of IGRT systems varies widely. Commonly used IGRT systems include electronic portal imaging with implanted fiducial markers, CBCT with or without implanted fiducial markers, and electromagnetic transponders.17, 18, 19
There is evidence that IGRT improves clinical outcomes. A recent study found that IGRT eliminates the increased risk of biochemical failure that is associated with rectal distension on planning CT20, which suggests a reduced rate of geometric misses of the prostate during EBRT. Additionally, de Crevoisier et al21 found that patients with a distended rectum on planning CT for prostate EBRT had significantly lower rates of biochemical control, likely because of geographical misses during EBRT delivery. Since that initial observation, much work has been done to improve target localization for prostate EBRT through image guidance strategies to address interfraction and intrafraction motion.22 There is no consensus with regard to the relative effectiveness of the various IGRT technologies,19 each of which has advantages and limitations.16
Ultrasound
Transabdominal 3-dimensional ultrasound (US) is used to localize the prostate for daily RT delivery with an accuracy that parallels CT scanning of the pelvis. US-based methods do not require the insertion of fiducials, and they allow localization without additional x-ray exposure. US is a useful tool for prostate localization with a suggested margin of 9 mm uniform PTV.23 Although US methods avoid x-ray exposure and have comparable accuracy,24 they are sensitive to subjective and training variability; thus, their role in tracking may be less than that provided with either fiducial or megavoltage CT methods. Moreover, the US procedure causes temporary prostatic displacement, and some investigators have suggested that overall, the residual errors are not significantly less than with weekly or daily pelvic x-ray imaging based on bony anatomy.
2-dimensional imaging with fiducial markers
Fiducial markers (eg, 1 mm diameter gold seeds) implanted in the prostate gland prior to EBRT simulation appear on electronic portal imaging kV or MV devices (EPIDs) or CBCT. The use of fiducial markers has resulted in improved accuracy compared with alignment of bony anatomy using portal images and has allowed for a reduction of the PTV margin from 11 to 14 mm (with bony alignment) to 4 to 7 mm.25
Using fiducial markers and EPIDs, Chung et al26 demonstrated that after the initial setup, displacements in the superior, inferior, anterior, and posterior directions were a maximum of 7, 9, 10, and 11 mm, respectively. After identification and correction, prostate displacements were <3 mm in all directions. Other studies have reported a similar reduction in errors with fiducial markers and daily position corrections.27 If corrections with implantable fiducial markers are done daily, the PTV margins should be at least 4.9, 5.1, and 4.8 mm in the left–right, superior–inferior, and AP directions, respectively. However, broader margins (6.7, 8.2, and 8.7 mm) are required if the correction is done weekly.28 Care should be taken when adapting to prostate motion while pelvic LNs are treated because this may lead to a degradation of the dose to pelvic LN PTV.29
In select patients, daily manual alignment to fiducials is one of the most reliable methods of maintaining accuracy in prostate IGRT, more so than CBCT with soft tissue–based automatic corrections.30 Implanting fiducials through either a transperineal or transrectal approach is an invasive procedure but has a low rate of complications.31 Although seeds may theoretically migrate, this is generally not a significant problem because fiducial markers have been shown to be stable within the prostate,32 even when implanted on the same day as the simulation.33 Exposure to ionizing radiation with daily imaging and the inability to visualize normal tissues are limitations of fiducial markers with planar imaging for tracking.34 Thus, although implanted gold fiducial markers have benefits over nonuse of IGRT, they do have some limitations.
When fiducial markers are placed, either the transrectal or transperineal insertion method is appropriate. Fiducial markers typically have been placed at least 1 week prior to CT simulation to avoid marker migration between placement and simulation. However, recent evidence suggests that placement immediately prior to simulation on the same day is reasonable because migration of fiducial markers over a 1-week period is typically estimated to be 1 mm or less.33
CBCT with or without implanted fiducial markers
Tomographic volumetric imaging capabilities allow daily capture of 3-dimensional image data for the intact prostate and after prostatectomy.35, 36 Both MV and kV CT reconstructions can display the daily position of the prostate and adjacent OARs , thereby allowing treatment position to be adjusted to ensure that the entirety of the target is in the daily treatment volume.37 It is important to note that CT-based methods of image guidance (whether kV or MV) may provide a spectrum of image quality and exposure levels.38 These differences in image quality are due to the range of energies and geometries that subsequently lead to various levels of soft tissue contrast and spatial resolution. Furthermore, differences in imaging doses to the patient have also been observed. In general, higher doses need to be applied to the patient when using MV systems to achieve the same image quality seen with some kV systems.
CBCT allows visualization of the prostate and OARs.39 The convenience of CBCT is its ability to produce high-quality images of soft tissues with excellent spatial resolution in a relatively brief amount of time (ie, less than a few minutes). Daily online correction allows the use of the suggested PTV margins of 4 to 5 mm in all directions and 3 mm posteriorly.40, 41
Compared with skin setup, MV CBCT can improve localization and justify a tighter margin.42 In an assessment by Schubert et al,43 global systematic error with daily MV CBCT was found to be 4.7 mm in the vertical direction and largely caused by couch sag. Despite low image quality, MV CBCT IGRT has a clear advantage in the presence of large artifacts, such as those caused by hip prostheses.44 Furthermore, it can allow direct dose calculation, dose-guided modifications, or adaptation to acquired images. However, the additional MV x-ray exposure is of concern. The American Association of Physicists in Medicine (AAPM) Task Group 75 provides further insight into the complexity of using MV CBCT.45
Finally, optimal use of the additional acquired information poses a challenge. Day-to-day organ position and shape changes may require adaptation of the dosimetry of the old plan or even development of a new plan. Nevertheless, image registration46 and dose guidance47, 48 offer opportunities to maximize the therapeutic ratio.
Electromagnetic transponders
Radiofrequency transponders can localize the prostate in a manner similar to that of gold markers but without additional radiation dose to the patient. These transponders can also be tracked in real time during a treatment session and allow for immediate intervention if the prostate moves outside of the radiation field.49 A unique advantage of this method is the correction of intrafraction error with possible reduction of PTV margin to 3 mm.50, 51 Limitations of radiofrequency transponders include the subsequent difficulty of prostate posttreatment follow-up with MRI and the minimal displacement of transponders during MRI acquisition.52 Furthermore, other limitations exist in the use of these transponders in patients with pacemakers and in very obese patients.
Impact of IGRT on PTV margins
Margins used to generate a PTV by expanding a CTV should consider the magnitude of setup errors and other uncertainties of EBRT. This has been described in detail by van Herk,53 including the conceptualization of how information regarding random and systematic errors can be used to estimate appropriate CTV-to-PTV expansions. Perez-Romasanta et al54 measured the interfraction prostate motion in the absence of intensive IGRT methods and calculated the CTV-to-PTV margins using the van Herk method. Their data suggest that localization based solely on tattoo marks and weekly imaging requires a margin of 9 to 10.5 mm in the left–right direction, 15.2 to 17.8 mm in the AP direction, and 10.6 to 12.4 mm in the superior–inferior direction.
Margin reduction is an important benefit of online image guidance. Wu et al55 evaluated CT images that were obtained in an online fashion during prostate EBRT and showed that CTV-to-PTV margins could be reduced with daily IGRT to a 3 mm margin to account for nonrigid and intrafraction motion. Similarly, Letourneau et al56 suggested 3 mm as the minimal CTV-to-PTV margin for daily IGRT with CBCT to represent the residual error after correction of interfraction and intrafraction motion. In an ideal scenario, ignoring potential intrafraction motion, online IGRT can allow an average of 13% higher EBRT dose to the prostate PTV without increasing the equivalent uniform dose to the rectum compared with EBRT without IGRT.57
A range of CTV-to-PTV expansion margins has been reported in treatment protocols for localized prostate cancer (Appendix 1). For prostate bed treatment, Sidhom et al58 recommended a uniform CTV-to-PTV margin of 10 mm. Song et al59 recommended a 0.6 to 0.9 cm anisotropic PTV margin when setting up to bony anatomy using data derived from surgical clips within the prostate bed and the van Herk method. The consensus guidelines by the European Organization for Research and Treatment of Cancer recommend a minimum margin of 5 mm.60
An adaptive approach for patient-specific CTV-to-PTV margins has been proposed in which daily online CT scans from the first week of EBRT are evaluated to determine random and systematic setup errors. The observed errors are then considered to create a new plan using a patient-specific CTV-to-PTV margin.61 Extending this an additional step, Schulze et al62 described an approach for online plan reoptimization to potentially increase the therapeutic ratio by performing online treatment planning with subsequent optimization.
It is important that PTV margins are appropriate for the level of precision in target localization and management of prostate gland motion. As an example of the importance of PTV margins, Engels et al63 reported a higher rate of biochemical failure when a variable 3 to 5 mm CTV-to-PTV margin was used compared with a 6 mm margin for patients who received daily IGRT with implanted fiducial markers. They also noticed that biochemical failure rates were higher when patients had rectal distension with a cross-sectional area of >9 cm2 on the planning CT.
It is therefore important that radiation oncologists consider only tight CTV-to-PTV margins when matched by appropriately precise EBRT delivery methods and quality assurance. The ACR Radiation Oncology Prostate Cancer Expert Panel concludes that, as a general rule, appropriate CTV-to-PTV margins should be ≥5 mm in routine practice and reduced to ≥3 mm only when methods are applied to monitor and correct for intrafraction motion of the prostate gland.
Radiation treatment delivery techniques
This section provides an overview of selected treatment delivery considerations for prostate EBRT, drawing on the available evidence. A separate set of ACR Appropriateness Criteria summarizes the clinical evidence to support the use of these various treatment approaches for prostate cancer.2
Photons
3-dimensional conformal radiation therapy
Three-dimensional conformal radiation therapy (3D-CRT) consists of EBRT delivery using forward-planned static fields with customized treatment planning and aperture design. Although there is limited evidence that directly compares 3D-CRT to IMRT or proton beam therapy, the available comparative data suggest that higher EBRT doses are more effective at achieving prostate specific antigen failure-free survival for localized prostate cancer and that safe dose escalation can be more readily achieved with the increased conformity of IMRT relative to 3D-CRT.64
Ongoing Radiation Therapy Oncology Group (RTOG) protocols 081565 and 092466 allow for either 3D-CRT or IMRT as long as specified EBRT planning objectives are satisfied. A minimum of 4 fields is recommended as well as photon energy of at least 6 MV.
IMRT
Static fields
IMRT is widely used for prostate cancer treatment. IMRT achieves highly conformal dose distributions and demands a high level of precision in treatment planning and delivery.67 Patient setup must be reproducible for IMRT, and daily image guided target localization is recommended. Patient-specific quality assurance (QA) must be performed, including verification of the treatment unit data, dose delivery, and independent monitor unit calculations.68 Detailed guidance with regard to delivery, treatment planning, and clinical implementation of IMRT is provided in a report from the AAPM.69 Photon energy of at least 6 MV is recommended for prostate IMRT, and 5 to 9 fields are typically used for a plan that encompasses the prostate gland.
Arcs
VMAT is an IMRT method that uses rotational arcs to deliver IMRT in a shorter period of time.70 VMAT provides dose distributions that are similar to static field IMRT and has been shown to shorten treatment time substantially, down to the range of 2 to 3 minutes.70 Shorter treatment time with VMAT may reduce the risk of significant intrafraction prostate motion relative to static field IMRT.8
SBRT
Prostate SBRT requires attention to the delivery of highly conformal RT and attention to precise target localization throughout the SBRT delivery process. SBRT may be delivered with either high-energy photons or protons.71, 72 The AAPM Task Group 101 report provides technical guidance on the general planning and delivery of SBRT, which is applicable to prostate SBRT.73 Careful immobilization, highly conformal treatment, and image guidance is recommended, with attention to monitoring and correcting for intrafraction motion during SBRT delivery.73
Boike et al74 published the results of their phase 1 clinical trial of prostate SBRT, in which the radiation dose was escalated to 50 Gy in 5 fractions without dose-limiting toxicity. In that trial, patients were treated with implanted gold fiducial markers or electromagnetic transponder beacons. Endorectal balloons were also used for simulation and treatment, and a bowel regimen was prescribed, including milk of magnesia the night before and a Fleet enema 30 to 60 minutes prior to simulation and treatment. Patients were advised to have a full bladder for simulation and treatment.74 The same approach was used for the subsequent phase 2 trial.75 Notably, 5% of patients experienced a late toxicity that required the placement of a colostomy bag.76
Daily image guidance strategies are necessary for SBRT to localize the prostate. Boike et al74 reported using MV or kV CT before each fraction to confirm proper fiducial marker alignment, rectal balloon position, and bladder filling. SBRT fractions were separated by a minimum of 36 hours.
Prostate SBRT has also been delivered in a cooperative group trial, RTOG 0938,77 for which accrual of more than 270 patients has been completed and data are maturing. The RTOG 0938 trial required image guidance with implanted radiopaque fiducial markers or electromagnetic transponder beacons. A minimum of 72 hours and maximum of 96 hours were permitted between each fraction of SBRT, with no more than 2 fractions per week. Patients were advised to have a full bladder during simulation and treatment by drinking 16 to 24 ounces of fluid 2 to 3 hours before treatment. A bowel regimen was also followed, including a low gas, low motility diet starting 1 day prior to treatment; 1 tablespoon of milk of magnesia the night before simulation and each treatment; and 1 Fleet enema 2 to 3 hours before simulation and each treatment.
The ACR–American Society for Radiation Oncology (ASTRO) practice parameters provide additional guidance on SBRT planning and delivery.71 A range of SBRT delivery options are permitted, including static fields or arc-based treatment with or without IMRT planning. Interventions to limit or correct for target volume movement during SBRT are recommended. Stereotactic localization of the target volume is recommended, including imaging and/or the use of fiducial markers. Detailed QA is recommended to confirm IGRT image quality and SBRT treatment planning.78
Protons
ACR-ASTRO practice parameters are available for proton beam EBRT delivery, which is an evolving technology for prostate cancer treatment.72 Proton beam energies in clinical use typically range from 70 MeV to 250 MeV, with higher energies achieving deeper tissue penetration. Proton beam therapy delivery systems include scattered, uniform scanning, and pencil-beam scanning systems, with differences in the potential hazards and concerns among the various systems. It is recommended that the margins used in treatment planning account for uncertainties in target volume localization, beam characteristics, and patient motion. Image guidance strategies are recommended for proton beam therapy.72 Most technical aspects of immobilization and image guidance for photon IMRT are also necessary for proton beam therapy, with additional emphasis on geometric uncertainties.68
Other guideline documents for EBRT planning and prostate cancer
There are several other guideline documents on EBRT planning that are relevant to this topic and may be of use to clinicians. The AAPM task group report to provide guidance on the delivery, treatment planning, and clinical implementation of IMRT was issued in 2003.69 AAPM Task Group 101 provides guidance on SBRT planning and delivery, including the technical aspects of treatment planning and delivery.73
The ACR Technical Standard for the Performance of Radiation Oncology Physics for External Beam Therapy provides guidance on the required steps of EBRT planning, QA, and delivery.68 The ACR-ASTRO Practice Parameters for the Performance of 3-dimensional EBRT, IMRT, SBRT, and IGRT provide additional guidance with regard to planning, delivery, QA, and personnel considerations.67, 68, 71 Specific AAPM Task Group reports are also available for IGRT using CT-based methods79 and for US-guided prostate EBRT,80 which include technical guidance regarding QA of these techniques.
Summary of recommendations
Variant 1
For the routine case of a patient with low-risk, clinically localized prostate cancer who will be treated with EBRT, the following pretreatment is recommended: presimulation bowel preparation,21, 81, 82 supine position83, 84, 85, 86 (although prone can sometimes be used87), with custom immobilization88, 89 and a full or comfortably full bladder. The patient should undergo a CT simulation.90 An MRI simulation is also recommended; this may be most helpful if the prostate contour is uncertain, in instances of unusual anatomy, or in the hands of inexperienced clinicians.91, 92, 93 Treatment planning can be performed with IMRT, either non-arcs (eg, step-and-shoot) or arcs.
Proton beam RT is controversial, and recommendations for proton RT reflect controversy within the field of radiation oncology. If protons are used, treatment on a protocol is encouraged. Notably, 3D-CRT typically is not appropriate if other options are available. Various options exist for image guidance, including radiofrequency transponders16, 17, 18, 26, 28, 39, 40, 41, 42, 43, 44, 45; CBCT with fiducials, aligned to the PTV; CBCT without fiducials, aligned to the PTV; 2-D imaging with fiducials; or US. On the other hand, it is generally not recommended to use CBCT that is aligned to bony anatomy or not use image guidance. RT fractionation is typically used with CFRT. HFRT and SBRT may be acceptable if the patient was treated per a previous protocol.
Variant 2
For a patient similar to the one in variant 1 but with a CT simulation that reveals a grossly distended rectum (gas and stool), it is recommended that the patient walk, have a bowel movement, or have an enema.81 Using a simulation that shows a grossly distended rectum would result in worse dosimetry94 and clinical outcome,21 but this may be unavoidable in certain patients.
Variant 3
For a patient similar to the one in variant 1 but with a CT simulation that reveals a very large-volume prostate (100 mL), continued planning with the current CT simulation is recommended. Using androgen deprivation therapy to downsize the gland is not necessary.95 Surgery can be considered if there are significant and intractable urinary obstructive symptoms or if other options are unacceptable. MRI simulation and fusion to CT simulation is usually appropriate because the CTV on the MRI is noted to be smaller than that on CT. Fractionation with SBRT is less preferable because the toxicities of SBRT in large glands have not been fully characterized.
Variant 4
For a patient similar to the one in variant 1 but with bilateral hip implants, treatment planning can still be performed with non-arc IMRT, arc-based IMRT (ie, VMAT), or helical tomotherapy IMRT. For arc-based IMRT, dosimetry may be improved by using more arcs96 and avoiding beams that pass through prostheses.97, 98, 99 If protons are used, anterior-oriented beams100 or oblique beams101 are recommended. Additionally, CT simulation with kV and MV CT images improves the range of uncertainties for planning.102 IGRT can again be performed with radiofrequency transponders,103 2-dimensional imaging with implanted fiducials, MV CT/CBCT with implanted fiducials, or with US.104 For simulation, CT simulation with kV CT can be used with a commercial algorithm to improve the CT Hounsfield number accuracy and structure visualization.105, 106 Additionally, MVCT can be used to assist planning to improve image resolution and permit calculation of electron density.107 Bilateral hip implants are not a contraindication to CT/MRI simulation.108 Bilateral hip implants are not a contraindication to any fractionation (eg, CFRT, HFRT, and SBRT).
Variant 5
For a patient similar to the one in variant 1 but with inflammatory bowel disease, simulation is unchanged. Similarly, IMRT can be used109, 110; proton beam therapy is controversial, and treatment on a clinical trial is encouraged. For IGRT, recommendations are largely unchanged. For RT fractionation, CFRT is recommended because limited published data exist with regard to patients with inflammatory bowel disease on HFRT or SBRT protocols.
Variant 6
For a patient similar to the one in variant 1, status postprostatectomy, with a recommendation for adjuvant EBRT, the principal options for IGRT include daily CT with alignment to soft tissue or daily CT with surgical clips. Additionally, daily CT with implanted fiducials,35, 36 daily CT with electromagnetic transponders,15 or daily kV orthogonal images can be used. Similar to the image guidance for an intact prostate, daily CT with alignment to bony anatomy or lack of image guidance is not recommended.
Variant 7
For a patient similar to the one in variant 1 but with high body mass index and a pannus that extends into the radiation field, immobilization of the pannus during simulation should be considered. IMRT can be used.95 If proton therapy is used, beam angles must be carefully considered because of the limitations in proton beam path length. For image guidance, the main differences (vs variant 1) are that (1) a pannus may obscure reading of the transponders (transponders can instead be used as fiducials if the signal cannot be obtained); and (2) US imaging may be less appropriate than other options (eg, daily CBCT with or without fiducial markers).
Supporting documents
Additional information on the ACR Appropriateness Criteria methodology and other supporting documents are available at www.acr.org/ac.
Footnotes
Conflicts of interest: Brian J. Davis MD, PhD (stocks from Pfizer, Inc.); Paul L. Nguyen MD (consulting related to Ferring and Medivation drugs; one-time advisory board member of Genome Dx); Shane Lloyd MD (consulting for Sirtex); and Benjamin Movsas MD (research support for Philips, Inc. and Varian, Inc.). The American College of Radiology seeks and encourages collaboration with other organizations on the development of its Appropriateness Criteria through society representation on expert panels. Participation by representatives from collaborating societies on the expert panel does not necessarily imply individual or society endorsement of the final document.
Appendix
Appendix 1.
Protocol/reference(s) | GTV and CTV | PTV |
---|---|---|
MD Anderson: RCT of 70 Gy vs 78 Gy Kuban, 2008 111 |
|
|
PROG 9509 RCT of 70.2 Gy vs 79.2 Gy Zietman, 2010 112 |
|
|
GETUG: RCT of 70 vs 80 Gy Beckendorf, 2004 113 |
|
|
Dutch CKVO96-10: RCT of 68 Gy vs 78 Gy Al Mamgami, 2008 114 |
|
|
UK MRC RT01: RCT of 64 Gy vs 74 Gy Dearnaley, 2007 115, 116 |
|
|
RTOG 0126 117: RCT of 70.2 Gy vs 79.2 Gy |
|
|
RTOG 0924 66: RCT of high-dose RT ± pelvic RT in intermediate- and high-risk patients |
|
|
CFRT, conventionally fractionated radiation therapy (ie, 1.8–2.0 Gy/fraction); CTV, clinical target volume; EBRT, external-beam radiation therapy; GETUG, Groupe d'Etude des Tumeurs Uro-Génitales; GTV, gross tumor volume; PTV, planning target volume; RCT, randomized controlled trial; RTOG, Radiation Therapy Oncology Group; SVs, seminal vesicles.
Note: All studies listed use conventionally fractionated radiation therapy (ie, 1.8–2.0 Gy / fraction).
Variant 1.
Treatment | Rating | Comments |
---|---|---|
Presimulation | This option is not required if performing image guidance but is an option that is not wrong for planning purposes. | |
Bowel prep | 7 | Microenema is recommended.81 Oral stool softener and antiflatulent agents are also options.21, 82 |
Supine position | 8 | See references.83, 84, 85, 86 |
Prone position | 5 | See reference.87 |
Custom immobilization (eg, with custom thermoplastic cast) | 8 | This option is per previously published reports.88, 89 |
Bladder | This treatment is dependent on institution. | |
Full | 7 | |
Comfortably full | 8 | |
Empty | 4 | |
Simulation Tools | ||
CT simulation | 8 | CT alone is possible in the hands of an experienced clinician.90 |
MRI simulation and fusion to CT | 7 | This procedure may be most helpful if the prostate contour is uncertain or in instances of unusual anatomy. See references.118, 119, 120, 91, 92, 93 |
Treatment Planning | ||
IMRT (non-arc) | 8 | |
IMRT (arc) | 8 | |
Proton beam | 6 | This reflects recognized controversy in the field. This procedure is unlikely to have worse outcomes than IMRT. Treatment on protocol is encouraged. |
3D-CRT | 5 | This procedure is acceptable if dose-volume histogram constraints are met or if IMRT is not available. |
Image Guidance | ||
Use of radiofrequency transponders | 7 | See references.16, 18, 26, 28, 39, 40, 41, 42, 43, 44, 45, 49, 50, 51, 52 |
CBCT with fiducial markers, aligned to PTV | 8 | |
CBCT without fiducial markers, aligned to PTV | 7 | |
CBCT, aligned to bony anatomy | 3 | The prostate gland is recognized to move independently of bony anatomy, so alignment based on the prostate PTV is recommended. |
2-D imaging with fiducial markers | 7 | |
Ultrasound | 7 | |
None | 3 | |
RT Fractionation | ||
CFRT (ie, 1.8–2.0 Gy/fraction) | 8 | |
HFRT (ie, 2.1–3.5 Gy/fraction) | 6 | This procedure is per previous protocol (eg, RTOG 0415 121). |
Stereotactic RT (ie, >3.5 Gy/fraction) | 6 | This procedure is probably acceptable, but head-to-head comparisons are limited currently. This procedure is per previous protocol (eg, RTOG 0938 77). |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
Variant 2.
Treatment | Rating | Comments |
---|---|---|
Use current simulation | 5 | This procedure may be appropriate but there was disagreement among panel members on the appropriateness rating as defined by the panel’s median rating. Distended rectum results in worse dosimetry 94 and clinical outcome 21. It may be controversial to not resimulate, but some patients will always have a distended rectum and image-guidance methods may protect against negative effects. |
Resimulate this case after intervention: | ||
Patient walking, bowel movement, enema | 8 | Enema may be most appropriate.81 |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
Variant 3.
Treatment | Rating | Comments |
---|---|---|
Continue planning using current CT simulation | 7 | Definitive EBRT for large prostates without ADT is associated with low rates of GU or GI toxicity.95 |
Use ADT for downsizing of gland | 4 | Consider this option if dosimetric criteria are not met on initial plan due to large prostate volume. |
Recommend for surgery rather than RT | 5 | This option is recommended if obstructive symptoms are present. |
RT Fractionation | ||
CFRT | 8 | |
HFRT | 5 | |
SBRT | 4 | The toxicities of SBRT in large prostate glands have not been fully characterized. |
Simulation | ||
CT simulation (kV CT) | 8 | |
MRI simulation and fusion to CT | 8 | Volume on MRI is noted to be smaller than that on CT.92 |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
Variant 4.
Treatment | Rating | Comments |
---|---|---|
Treatment Planning | ||
IMRT (non-arc) | 8 | Dosimetry may be improved by avoiding beams that pass through prostheses.97, 98, 99 |
VMAT (arc-based IMRT) | 8 | Dosimetry may be improved by using more arcs.96 |
IMRT (helical tomotherapy) | 7 | This procedure has been previously described.44 |
Proton beam | 5 | This procedure reflects recognized controversy in the field. Use anterior-oriented beams 100 or oblique beams.101 CT simulation with kV and MV CT images improves range of uncertainties for planning.102 |
IGRT | ||
Radiofrequency transponders | 7 | Hip implants have no meaningful effect on image guidance with this strategy.103 |
2-D imaging with implanted fiducial markers | 7 | |
MVCT/CBCT with fiducial markers | 7 | |
Ultrasound | 7 | This procedure is for reference.104 |
Simulation | ||
CT simulation (kV CT) | 8 | Use a commercial algorithm to improve CT Hounsfield number accuracy and structure visualization.99, 105, 106 |
Use MVCT to assist planning if available | 7 | This procedure may improve image resolution and permit calculation of electron density.107 |
MRI simulation and fusion to CT | 8 | Bilateral hip implants are not a contraindication to CT/MRI simulation.122 |
None | 3 | |
RT Fractionation | ||
CFRT | 8 | This procedure is not a contraindication on previous protocol (ie, RTOG 9406 123). |
HFRT | 6 | This procedure is not a contraindication on previous protocol (ie, RTOG 0415 121). |
SBRT | 6 | This procedure is not a contraindication on previous protocol (ie, RTOG 0938 77). |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
Variant 5.
Treatment | Rating | Comments |
---|---|---|
Simulation | 8 | There is no effect on simulation. |
Treatment Planning | ||
IMRT (non-arc) | 8 | There are reportedly low complications with photon EBRT 109, 110. |
IMRT (arc) | 8 | There are reportedly low complications with photon EBRT 109, 110. |
Proton beam | 5 | This procedure may be appropriate but there was disagreement among panel members on the appropriateness rating as defined by the panel’s median rating. This reflects recognized controversy in the field. Treatment on a clinical trial is encouraged. |
IGRT | ||
CBCT with radiofrequency transponders | 7 | This is expert opinion. There is no published evidence on the optimal method for image guidance. |
CBCT with fiducial markers, aligned to PTV | 8 | This is expert opinion. There is no published evidence on the optimal method for image guidance. |
CBCT without fiducial markers, aligned to PTV | 7 | |
CBCT, aligned to bony anatomy | 3 | The prostate gland is recognized to move independently of bony anatomy, so alignment based on the prostate PTV is recommended. |
2-D imaging with fiducial markers | 7 | |
Ultrasound | 7 | |
None | 2 | |
RT Fractionation | ||
CFRT | 8 | |
HFRT | 4 | There is limited evidence regarding the safety of HFRT in inflammatory bowel disease. |
SBRT | 4 | There is limited evidence in inflammatory bowel disease. |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
Variant 6.
Treatment | Rating | Comments |
---|---|---|
IGRT | ||
Daily CT with soft-tissue alignment | 7 | There are no specific recommendations on RTOG 0534.124 CBCT with fiducial markers is reasonable.35, 36 |
Daily CT with implanted fiducial markers | 6 | It is uncertain if fiducial markers are stable, similar to the intact prostate setting. |
Daily CT with surgical clips | 7 | This procedure may be used if other options are not available; however, clinicians should note that these clips may not appear clearly on CBCT. |
Daily CT with alignment of bony anatomy | 4 | The prostate gland is recognized to move independently of bony anatomy, so alignment based on the prostate PTV is recommended. |
Daily kV orthogonals | 6 | The prostate gland is recognized to move independently of bony anatomy, so alignment based on the prostate PTV is recommended. |
Electromagnetic transponders | 6 | There are typically 3 beacons placed: 2 lateral to the ureterovesicular anastomosis and 1 distal in the retrovesical tissue where the SVs had been. The beacons are typically 1 cm apart from each other.15 |
None | 3 |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
Variant 7.
Treatment | Rating | Comments |
---|---|---|
Simulation | ||
Immobilization of pannus (eg, tape or cover sheet) | 7 | There may be considerable variability. |
Treatment Planning | Limiting beam angles can be considered. For low-risk patients, one can consider weight loss prior to starting treatment. | |
IMRT (non-arc) | 8 | |
IMRT (arc) | 8 | One can consider limiting arcs. |
Proton beam | 6 | Beam angles for proton beam therapy must be carefully considered due to limitations in proton beam path length. |
IGRT | ||
Electromagnetic transponders | 4 | Obesity may obscure reading of transponders. In borderline cases, the transponders may be used as fiducial markers if the signal cannot be obtained. |
Daily CBCT with fiducial markers | 8 | |
Daily CBCT without fiducial markers | 7 | |
Daily planar imaging with fiducial markers | 7 | |
Daily ultrasound imaging | 5 |
Rating Scale: 1,2,3 Usually not appropriate; 4,5,6 May be appropriate; 7,8,9 Usually appropriate
References
- 1.Gustafson G.S., Nguyen P.L., Assimos D.G. ACR Appropriateness Criteria® postradical prostatectomy irradiation in prostate cancer. Oncology (Williston Park) 2014;28:1125–1130. 1132-1126. [PubMed] [Google Scholar]
- 2.Nguyen P.L., Aizer A., Assimos D.G. ACR Appropriateness Criteria® definitive external-beam irradiation in stage T1 and T2 prostate cancer. Am J Clin Oncol. 2014;37:278–288. doi: 10.1097/COC.0000000000000049. [DOI] [PubMed] [Google Scholar]
- 3.Gill S., Dang K., Fox C. Seminal vesicle intrafraction motion analysed with cinematic magnetic resonance imaging. Radiat Oncol. 2014;9:174. doi: 10.1186/1748-717X-9-174. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Frank S.J., Dong L., Kudchadker R.J. Quantification of prostate and seminal vesicle interfraction variation during IMRT. Int J Radiat Oncol Biol Phys. 2008;71:813–820. doi: 10.1016/j.ijrobp.2007.10.028. [DOI] [PubMed] [Google Scholar]
- 5.Beltran C., Herman M.G., Davis B.J. Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods. Int J Radiat Oncol Biol Phys. 2008;70:289–295. doi: 10.1016/j.ijrobp.2007.08.040. [DOI] [PubMed] [Google Scholar]
- 6.Wong J.R., Gao Z., Uematsu M. Interfractional prostate shifts: Review of 1870 computed tomography (CT) scans obtained during image-guided radiotherapy using CT-on-rails for the treatment of prostate cancer. Int J Radiat Oncol Biol Phys. 2008;72:1396–1401. doi: 10.1016/j.ijrobp.2008.03.045. [DOI] [PubMed] [Google Scholar]
- 7.Graf R., Boehmer D., Budach V., Wust P. Interfraction rotation of the prostate as evaluated by kilovoltage x-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer. Med Dosim. 2012;37:396–400. doi: 10.1016/j.meddos.2012.02.006. [DOI] [PubMed] [Google Scholar]
- 8.Badakhshi H., Wust P., Budach V., Graf R. Image-guided radiotherapy with implanted markers and kilovoltage imaging and 6-dimensional position corrections for intrafractional motion of the prostate. Anticancer Res. 2013;33:4117–4121. [PubMed] [Google Scholar]
- 9.Cramer A.K., Haile A.G., Ognjenovic S. Real-time prostate motion assessment: Image-guidance and the temporal dependence of intra-fraction motion. BMC Med Phys. 2013;13:4. doi: 10.1186/1756-6649-13-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Shelton J., Rossi P.J., Chen H., Liu Y., Master V.A., Jani A.B. Observations on prostate intrafraction motion and the effect of reduced treatment time using volumetric modulated arc therapy. Pract Radiat Oncol. 2011;1:243–250. doi: 10.1016/j.prro.2011.02.008. [DOI] [PubMed] [Google Scholar]
- 11.de Crevoisier R., Melancon A.D., Kuban D.A. Changes in the pelvic anatomy after an IMRT treatment fraction of prostate cancer. Int J Radiat Oncol Biol Phys. 2007;68:1529–1536. doi: 10.1016/j.ijrobp.2007.01.069. [DOI] [PubMed] [Google Scholar]
- 12.Liang J., Wu Q., Yan D. The role of seminal vesicle motion in target margin assessment for online image-guided radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys. 2009;73:935–943. doi: 10.1016/j.ijrobp.2008.10.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Adamczyk M., Piotrowski T., Adamiak E., Malicki J. Dosimetric consequences of prostate-based couch shifts on the precision of dose delivery during simultaneous IMRT irradiation of the prostate, seminal vesicles and pelvic lymph nodes. Phys Med. 2014;30:228–233. doi: 10.1016/j.ejmp.2013.06.003. [DOI] [PubMed] [Google Scholar]
- 14.Huang K., Palma D.A., Scott D. Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2012;84:402–407. doi: 10.1016/j.ijrobp.2011.12.035. [DOI] [PubMed] [Google Scholar]
- 15.Klayton T., Price R., Buyyounouski M.K. Prostate bed motion during intensity-modulated radiotherapy treatment. Int J Radiat Oncol Biol Phys. 2012;84:130–136. doi: 10.1016/j.ijrobp.2011.11.041. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Zaorsky N.G., Harrison A.S., Trabulsi E.J. Evolution of advanced technologies in prostate cancer radiotherapy. Nat Rev Urol. 2013;10:565–579. doi: 10.1038/nrurol.2013.185. [DOI] [PubMed] [Google Scholar]
- 17.Button M.R., Staffurth J.N. Clinical application of image-guided radiotherapy in bladder and prostate cancer. Clin Oncol (R Coll Radiol) 2010;22:698–706. doi: 10.1016/j.clon.2010.06.020. [DOI] [PubMed] [Google Scholar]
- 18.Stephans K.L., Xia P., Tendulkar R.D., Ciezki J.P. The current status of image-guided external beam radiotherapy for prostate cancer. Curr Opin Urol. 2010;20:223–228. doi: 10.1097/MOU.0b013e32833817aa. [DOI] [PubMed] [Google Scholar]
- 19.Das S., Liu T., Jani A.B. Comparison of image-guided radiotherapy technologies for prostate cancer. Am J Clin Oncol. 2014;37:616–623. doi: 10.1097/COC.0b013e31827e4eb9. [DOI] [PubMed] [Google Scholar]
- 20.Park S.S., Yan D., McGrath S. Adaptive image-guided radiotherapy (IGRT) eliminates the risk of biochemical failure caused by the bias of rectal distension in prostate cancer treatment planning: clinical evidence. Int J Radiat Oncol Biol Phys. 2012;83:947–952. doi: 10.1016/j.ijrobp.2011.08.025. [DOI] [PubMed] [Google Scholar]
- 21.de Crevoisier R., Tucker S.L., Dong L. Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys. 2005;62:965–973. doi: 10.1016/j.ijrobp.2004.11.032. [DOI] [PubMed] [Google Scholar]
- 22.Kupelian P.A., Langen K.M., Willoughby T.R., Zeidan O.A., Meeks S.L. Image-guided radiotherapy for localized prostate cancer: treating a moving target. Semin Radiat Oncol. 2008;18:58–66. doi: 10.1016/j.semradonc.2007.09.008. [DOI] [PubMed] [Google Scholar]
- 23.Poli M.E., Parker W., Patrocinio H. An assessment of PTV margin definitions for patients undergoing conformal 3D external beam radiation therapy for prostate cancer based on an analysis of 10,327 pretreatment daily ultrasound localizations. Int J Radiat Oncol Biol Phys. 2007;67:1430–1437. doi: 10.1016/j.ijrobp.2006.11.004. [DOI] [PubMed] [Google Scholar]
- 24.Boda-Heggemann J., Kohler F.M., Kupper B. Accuracy of ultrasound-based (BAT) prostate-repositioning: A three-dimensional on-line fiducial-based assessment with cone-beam computed tomography. Int J Radiat Oncol Biol Phys. 2008;70:1247–1255. doi: 10.1016/j.ijrobp.2007.12.003. [DOI] [PubMed] [Google Scholar]
- 25.Greer P.B., Dahl K., Ebert M.A., Wratten C., White M., Denham J.W. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections. J Med Imaging Radiat Oncol. 2008;52:511–516. doi: 10.1111/j.1440-1673.2008.02005.x. [DOI] [PubMed] [Google Scholar]
- 26.Chung P.W., Haycocks T., Brown T. On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma. Int J Radiat Oncol Biol Phys. 2004;60:329–334. doi: 10.1016/j.ijrobp.2004.03.038. [DOI] [PubMed] [Google Scholar]
- 27.Beaulieu L., Girouard L.M., Aubin S. Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm. Radiother Oncol. 2004;73:61–64. doi: 10.1016/j.radonc.2004.06.006. [DOI] [PubMed] [Google Scholar]
- 28.Graf R., Wust P., Budach V., Boehmer D. Potentials of on-line repositioning based on implanted fiducial markers and electronic portal imaging in prostate cancer radiotherapy. Radiat Oncol. 2009;4:13. doi: 10.1186/1748-717X-4-13. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Rossi P.J., Schreibmann E., Jani A.B., Master V.A., Johnstone P.A. Boost first, eliminate systematic error, and individualize CTV to PTV margin when treating lymph nodes in high-risk prostate cancer. Radiother Oncol. 2009;90:353–358. doi: 10.1016/j.radonc.2008.09.021. [DOI] [PubMed] [Google Scholar]
- 30.Shi W., Li J.G., Zlotecki R.A. Evaluation of kV cone-beam CT performance for prostate IGRT: a comparison of automatic grey-value alignment to implanted fiducial-marker alignment. Am J Clin Oncol. 2011;34:16–21. doi: 10.1097/COC.0b013e3181d26b1a. [DOI] [PubMed] [Google Scholar]
- 31.Ng M., Brown E., Williams A., Chao M., Lawrentschuk N., Chee R. Fiducial markers and spacers in prostate radiotherapy: Current applications. BJU Int. 2014;113:13–20. doi: 10.1111/bju.12624. [DOI] [PubMed] [Google Scholar]
- 32.Schallenkamp J.M., Herman M.G., Kruse J.J., Pisansky T.M. Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging. Int J Radiat Oncol Biol Phys. 2005;63:800–811. doi: 10.1016/j.ijrobp.2005.02.022. [DOI] [PubMed] [Google Scholar]
- 33.Kumar K.A., Wu T., Tonlaar N., Stepaniak C., Yenice K.M., Liauw S.L. Image-guided radiation therapy for prostate cancer: A computed tomography-based assessment of fiducial marker migration between placement and 7 days. Pract Radiat Oncol. 2015;5:241–247. doi: 10.1016/j.prro.2014.11.007. [DOI] [PubMed] [Google Scholar]
- 34.Nichol A.M., Brock K.K., Lockwood G.A. A magnetic resonance imaging study of prostate deformation relative to implanted gold fiducial markers. Int J Radiat Oncol Biol Phys. 2007;67:48–56. doi: 10.1016/j.ijrobp.2006.08.021. [DOI] [PubMed] [Google Scholar]
- 35.Chua B., Min M., Wood M. Implementation of an image guided intensity-modulated protocol for post-prostatectomy radiotherapy: planning data and acute toxicity outcomes. J Med Imaging Radiat Oncol. 2013;57:482–489. doi: 10.1111/1754-9485.12043. [DOI] [PubMed] [Google Scholar]
- 36.Eldredge H.B., Studenski M., Keith S.W. Post-prostatectomy image-guided radiation therapy: evaluation of toxicity and inter-fraction variation using online cone-beam CT. J Med Imaging Radiat Oncol. 2011;55:507–515. doi: 10.1111/j.1754-9485.2011.02305.x. [DOI] [PubMed] [Google Scholar]
- 37.Court L.E., Dong L., Lee A.K. An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer. Int J Radiat Oncol Biol Phys. 2005;62:154–163. doi: 10.1016/j.ijrobp.2004.09.045. [DOI] [PubMed] [Google Scholar]
- 38.Stutzel J., Oelfke U., Nill S. A quantitative image quality comparison of four different image guided radiotherapy devices. Radiother Oncol. 2008;86:20–24. doi: 10.1016/j.radonc.2007.10.035. [DOI] [PubMed] [Google Scholar]
- 39.Moseley D.J., White E.A., Wiltshire K.L. Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys. 2007;67:942–953. doi: 10.1016/j.ijrobp.2006.10.039. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Hammoud R., Patel S.H., Pradhan D. Examining margin reduction and its impact on dose distribution for prostate cancer patients undergoing daily cone-beam computed tomography. Int J Radiat Oncol Biol Phys. 2008;71:265–273. doi: 10.1016/j.ijrobp.2008.01.015. [DOI] [PubMed] [Google Scholar]
- 41.Pawlowski J.M., Yang E.S., Malcolm A.W., Coffey C.W., Ding G.X. Reduction of dose delivered to organs at risk in prostate cancer patients via image-guided radiation therapy. Int J Radiat Oncol Biol Phys. 2010;76:924–934. doi: 10.1016/j.ijrobp.2009.06.068. [DOI] [PubMed] [Google Scholar]
- 42.Ramsey C.R., Scaperoth D., Seibert R., Chase D., Byrne T., Mahan S. Image-guided helical tomotherapy for localized prostate cancer: technique and initial clinical observations. J Appl Clin Med Phys. 2007;8:2320. doi: 10.1120/jacmp.v8i3.2320. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Schubert L.K., Westerly D.C., Tome W.A. A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments. Int J Radiat Oncol Biol Phys. 2009;73:1260–1269. doi: 10.1016/j.ijrobp.2008.11.054. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Sterzing F., Kalz J., Sroka-Perez G. Megavoltage CT in helical tomotherapy-clinical advantages and limitations of special physical characteristics. Technol Cancer Res Treat. 2009;8:343–352. doi: 10.1177/153303460900800504. [DOI] [PubMed] [Google Scholar]
- 45.Murphy M.J., Balter J., Balter S. The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75. Med Phys. 2007;34:4041–4063. doi: 10.1118/1.2775667. [DOI] [PubMed] [Google Scholar]
- 46.Fu W., Yang Y., Yue N.J., Heron D.E., Huq M.S. A cone beam CT-guided online plan modification technique to correct interfractional anatomic changes for prostate cancer IMRT treatment. Phys Med Biol. 2009;54:1691–1703. doi: 10.1088/0031-9155/54/6/019. [DOI] [PubMed] [Google Scholar]
- 47.Cheung J., Aubry J.F., Yom S.S., Gottschalk A.R., Celi J.C., Pouliot J. Dose recalculation and the Dose-Guided Radiation Therapy (DGRT) process using megavoltage cone-beam CT. Int J Radiat Oncol Biol Phys. 2009;74:583–592. doi: 10.1016/j.ijrobp.2008.12.034. [DOI] [PubMed] [Google Scholar]
- 48.Varadhan R., Hui S.K., Way S., Nisi K. Assessing prostate, bladder and rectal doses during image guided radiation therapy–need for plan adaptation? J Appl Clin Med Phys. 2009;10:2883. doi: 10.1120/jacmp.v10i3.2883. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Balter J.M., Wright J.N., Newell L.J. Accuracy of a wireless localization system for radiotherapy. Int J Radiat Oncol Biol Phys. 2005;61:933–937. doi: 10.1016/j.ijrobp.2004.11.009. [DOI] [PubMed] [Google Scholar]
- 50.Langen K.M., Willoughby T.R., Meeks S.L. Observations on real-time prostate gland motion using electromagnetic tracking. Int J Radiat Oncol Biol Phys. 2008;71:1084–1090. doi: 10.1016/j.ijrobp.2007.11.054. [DOI] [PubMed] [Google Scholar]
- 51.Litzenberg D.W., Balter J.M., Hadley S.W. Influence of intrafraction motion on margins for prostate radiotherapy. Int J Radiat Oncol Biol Phys. 2006;65:548–553. doi: 10.1016/j.ijrobp.2005.12.033. [DOI] [PubMed] [Google Scholar]
- 52.Zhu X., Bourland J.D., Yuan Y. Tradeoffs of integrating real-time tracking into IGRT for prostate cancer treatment. Phys Med Biol. 2009;54:N393–N401. doi: 10.1088/0031-9155/54/17/N03. [DOI] [PubMed] [Google Scholar]
- 53.van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol. 2004;14:52–64. doi: 10.1053/j.semradonc.2003.10.003. [DOI] [PubMed] [Google Scholar]
- 54.Perez-Romasanta L.A., Lozano-Martin E., Velasco-Jimenez J. CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans. Clin Transl Oncol. 2009;11:615–621. doi: 10.1007/s12094-009-0413-z. [DOI] [PubMed] [Google Scholar]
- 55.Wu Q., Ivaldi G., Liang J., Lockman D., Yan D., Martinez A. Geometric and dosimetric evaluations of an online image-guidance strategy for 3D-CRT of prostate cancer. Int J Radiat Oncol Biol Phys. 2006;64:1596–1609. doi: 10.1016/j.ijrobp.2005.12.029. [DOI] [PubMed] [Google Scholar]
- 56.Letourneau D., Martinez A.A., Lockman D. Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. Int J Radiat Oncol Biol Phys. 2005;62:1239–1246. doi: 10.1016/j.ijrobp.2005.03.035. [DOI] [PubMed] [Google Scholar]
- 57.Ghilezan M., Yan D., Liang J., Jaffray D., Wong J., Martinez A. Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery. Int J Radiat Oncol Biol Phys. 2004;60:1602–1610. doi: 10.1016/j.ijrobp.2004.07.709. [DOI] [PubMed] [Google Scholar]
- 58.Sidhom M.A., Kneebone A.B., Lehman M. Post-prostatectomy radiation therapy: consensus guidelines of the Australian and New Zealand Radiation Oncology Genito-Urinary Group. Radiother Oncol. 2008;88:10–19. doi: 10.1016/j.radonc.2008.05.006. [DOI] [PubMed] [Google Scholar]
- 59.Song D.Y., Herfarth K.K., Uhl M. A multi-institutional clinical trial of rectal dose reduction via injected polyethylene-glycol hydrogel during intensity modulated radiation therapy for prostate cancer: analysis of dosimetric outcomes. Int J Radiat Oncol Biol Phys. 2013;87:81–87. doi: 10.1016/j.ijrobp.2012.12.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Poortmans P., Bossi A., Vandeputte K. Guidelines for target volume definition in post-operative radiotherapy for prostate cancer, on behalf of the EORTC Radiation Oncology Group. Radiother Oncol. 2007;84:121–127. doi: 10.1016/j.radonc.2007.07.017. [DOI] [PubMed] [Google Scholar]
- 61.Yan D., Lockman D., Brabbins D., Tyburski L., Martinez A. An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. Int J Radiat Oncol Biol Phys. 2000;48:289–302. doi: 10.1016/s0360-3016(00)00608-8. [DOI] [PubMed] [Google Scholar]
- 62.Schulze D., Liang J., Yan D., Zhang T. Comparison of various online IGRT strategies: The benefits of online treatment plan re-optimization. Radiother Oncol. 2009;90:367–376. doi: 10.1016/j.radonc.2008.08.012. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Engels B., Soete G., Gevaert T., Storme G., Michielsen D., De Ridder M. Impact of planning target volume margins and rectal distention on biochemical failure in image-guided radiotherapy of prostate cancer. Radiother Oncol. 2014;111:106–109. doi: 10.1016/j.radonc.2014.02.009. [DOI] [PubMed] [Google Scholar]
- 64.Hummel S., Simpson E.L., Hemingway P., Stevenson M.D., Rees A. Intensity-modulated radiotherapy for the treatment of prostate cancer: a systematic review and economic evaluation. Health Technol Assess. 2010;14:1–108. doi: 10.3310/hta14470. iii-iv. [DOI] [PubMed] [Google Scholar]
- 65.Martinez A.A. RTOG 0815: A phase III prospective randomized trial of dose-escalated radiotherapy with or without short-term androgen deprivation therapy for patients with intermediate-risk prostate cancer. http://www.rtog.org/clinicaltrials/protocoltable/studydetails.aspx?study=0815 Available at: Accessed April 24, 2015.
- 66.Roach M. RTOG 0924: Androgen deprivation therapy and high dose radiotherapy with or without whole-pelvic radiotherapy in unfavorable intermediate or favorable high risk prostate cancer: A phase III randomized trial. http://www.rtog.org/ClinicalTrials/ProtocolTable/StudyDetails.aspx?study=0924 Available at: Accessed April 24, 2015.
- 67.American College of Radiology ACR–ASTRO practice parameter for intensity modulated radiation therapy (IMRT) http://www.acr.org/∼/media/ACR/Documents/PGTS/guidelines/IMRT.pdf Available at: Accessed April 24, 2015.
- 68.American College of Radiology ACR technical standard for the performance of radiation oncology physics for external beam therapy. http://www.acr.org/∼/media/ACR/Documents/PGTS/standards/ROPhysicsExtBeamTherapy.pdf Available at: Accessed April 24, 2015.
- 69.Ezzell G.A., Galvin J.M., Low D. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. Med Phys. 2003;30:2089–2115. doi: 10.1118/1.1591194. [DOI] [PubMed] [Google Scholar]
- 70.Wolff D., Stieler F., Welzel G. Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. Radiother Oncol. 2009;93:226–233. doi: 10.1016/j.radonc.2009.08.011. [DOI] [PubMed] [Google Scholar]
- 71.American College of Radiology ACR–ASTRO practice parameter for the performance of stereotactic body radiation therapy. http://www.acr.org/∼/media/ACR/Documents/PGTS/guidelines/Stereo_body_radiation.pdf Available at: Accessed April 24, 2015. [DOI] [PubMed]
- 72.American College of Radiology ACR–ASTRO practice parameter for the performance of proton beam radiation therapy. http://www.acr.org/∼/media/ACR/Documents/PGTS/guidelines/Rad_Onc_Proton_Therapy.pdf Available at: Accessed April 24, 2015. [DOI] [PubMed]
- 73.Benedict S.H., Yenice K.M., Followill D. Stereotactic body radiation therapy: The report of AAPM Task Group 101. Med Phys. 2010;37:4078–4101. doi: 10.1118/1.3438081. [DOI] [PubMed] [Google Scholar]
- 74.Boike T.P., Lotan Y., Cho L.C. Phase I dose-escalation study of stereotactic body radiation therapy for low- and intermediate-risk prostate cancer. J Clin Oncol. 2011;29:2020–2026. doi: 10.1200/JCO.2010.31.4377. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75.Kim D.W., Straka C., Cho L.C., Timmerman R.D. Stereotactic body radiation therapy for prostate cancer: Review of experience of a multicenter phase I/II dose-escalation study. Front Oncol. 2014;4:319. doi: 10.3389/fonc.2014.00319. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76.Kim D.W., Cho L.C., Straka C. Predictors of rectal tolerance observed in a dose-escalated phase 1-2 trial of stereotactic body radiation therapy for prostate cancer. Int J Radiat Oncol Biol Phys. 2014;89:509–517. doi: 10.1016/j.ijrobp.2014.03.012. [DOI] [PubMed] [Google Scholar]
- 77.Lukka H. RTOG 0938: A randomized phase II trial of hypofractionated radiotherapy for favorable risk prostate cancer. http://www.rtog.org/ClinicalTrials/ProtocolTable/StudyDetails.aspx?study=0938 Available at: Accessed April 24, 2015.
- 78.American College of Radiology ACR–ASTRO practice parameter for image-guided radiation therapy (IGRT) http://www.acr.org/∼/media/ACR/Documents/PGTS/guidelines/IGRT.pdf Available at: Accessed April 24, 2015. [DOI] [PubMed]
- 79.Bissonnette J.P., Balter P.A., Dong L. Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179. Med Phys. 2012;39:1946–1963. doi: 10.1118/1.3690466. [DOI] [PubMed] [Google Scholar]
- 80.Molloy J.A., Chan G., Markovic A. Quality assurance of U.S.-guided external beam radiotherapy for prostate cancer: Report of AAPM Task Group 154. Med Phys. 2011;38:857–871. doi: 10.1118/1.3531674. [DOI] [PubMed] [Google Scholar]
- 81.Yahya S., Zarkar A., Southgate E., Nightingale P., Webster G. Which bowel preparation is best? Comparison of a high-fibre diet leaflet, daily microenema and no preparation in prostate cancer patients treated with radical radiotherapy to assess the effect on planned target volume shifts due to rectal distension. Br J Radiol. 2013;86:20130457. doi: 10.1259/bjr.20130457. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Nichol A.M., Warde P.R., Lockwood G.A. A cinematic magnetic resonance imaging study of milk of magnesia laxative and an antiflatulent diet to reduce intrafraction prostate motion. Int J Radiat Oncol Biol Phys. 2010;77:1072–1078. doi: 10.1016/j.ijrobp.2009.06.005. [DOI] [PubMed] [Google Scholar]
- 83.Kitamura K., Shirato H., Seppenwoolde Y. Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. Int J Radiat Oncol Biol Phys. 2002;53:1117–1123. doi: 10.1016/s0360-3016(02)02882-1. [DOI] [PubMed] [Google Scholar]
- 84.McLaughlin P.W., Wygoda A., Sahijdak W. The effect of patient position and treatment technique in conformal treatment of prostate cancer. Int J Radiat Oncol Biol Phys. 1999;45:407–413. doi: 10.1016/s0360-3016(99)00207-2. [DOI] [PubMed] [Google Scholar]
- 85.Vargas C., Saito A.I., Hsi W.C. Cine-magnetic resonance imaging assessment of intrafraction motion for prostate cancer patients supine or prone with and without a rectal balloon. Am J Clin Oncol. 2010;33:11–16. doi: 10.1097/COC.0b013e31819fdf7c. [DOI] [PubMed] [Google Scholar]
- 86.Wilder R.B., Chittenden L., Mesa A.V. A prospective study of intrafraction prostate motion in the prone vs. supine position. Int J Radiat Oncol Biol Phys. 2010;77:165–170. doi: 10.1016/j.ijrobp.2009.04.041. [DOI] [PubMed] [Google Scholar]
- 87.Liu B., Lerma F.A., Patel S. Dosimetric effects of the prone and supine positions on image guided localized prostate cancer radiotherapy. Radiother Oncol. 2008;88:67–76. doi: 10.1016/j.radonc.2007.11.034. [DOI] [PubMed] [Google Scholar]
- 88.Dawson L.A., Litzenberg D.W., Brock K.K. A comparison of ventilatory prostate movement in four treatment positions. Int J Radiat Oncol Biol Phys. 2000;48:319–323. doi: 10.1016/s0360-3016(00)00751-3. [DOI] [PubMed] [Google Scholar]
- 89.Malone S., Crook J.M., Kendal W.S., Szanto J. Respiratory-induced prostate motion: quantification and characterization. Int J Radiat Oncol Biol Phys. 2000;48:105–109. doi: 10.1016/s0360-3016(00)00603-9. [DOI] [PubMed] [Google Scholar]
- 90.McLaughlin P.W., Evans C., Feng M., Narayana V. Radiographic and anatomic basis for prostate contouring errors and methods to improve prostate contouring accuracy. Int J Radiat Oncol Biol Phys. 2010;76:369–378. doi: 10.1016/j.ijrobp.2009.02.019. [DOI] [PubMed] [Google Scholar]
- 91.Parker C.C., Damyanovich A., Haycocks T., Haider M., Bayley A., Catton C.N. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration. Radiother Oncol. 2003;66:217–224. doi: 10.1016/s0167-8140(02)00407-3. [DOI] [PubMed] [Google Scholar]
- 92.Rasch C., Barillot I., Remeijer P., Touw A., van Herk M., Lebesque J.V. Definition of the prostate in CT and MRI: a multi-observer study. Int J Radiat Oncol Biol Phys. 1999;43:57–66. doi: 10.1016/s0360-3016(98)00351-4. [DOI] [PubMed] [Google Scholar]
- 93.Steenbakkers R.J., Deurloo K.E., Nowak P.J., Lebesque J.V., van Herk M., Rasch C.R. Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate. Int J Radiat Oncol Biol Phys. 2003;57:1269–1279. doi: 10.1016/s0360-3016(03)01446-9. [DOI] [PubMed] [Google Scholar]
- 94.Guckenberger M., Pohl F., Baier K., Meyer J., Vordermark D., Flentje M. Adverse effect of a distended rectum in intensity-modulated radiotherapy (IMRT) treatment planning of prostate cancer. Radiother Oncol. 2006;79:59–64. doi: 10.1016/j.radonc.2006.03.004. [DOI] [PubMed] [Google Scholar]
- 95.McGee L., Mendenhall N.P., Henderson R.H. Outcomes in men with large prostates (>/= 60 cm(3)) treated with definitive proton therapy for prostate cancer. Acta Oncol. 2013;52:470–476. doi: 10.3109/0284186X.2012.744467. [DOI] [PubMed] [Google Scholar]
- 96.Rana S.B., Pokharel S. A dosimetric study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses. South Asian J Cancer. 2014;3:18–21. doi: 10.4103/2278-330X.126506. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97.van der Est H., Prins P., Heijmen B.J., Dirkx M.L. Intensity modulated radiation therapy planning for patients with a metal hip prosthesis based on class solutions. Pract Radiat Oncol. 2012;2:35–40. doi: 10.1016/j.prro.2011.04.006. [DOI] [PubMed] [Google Scholar]
- 98.Voet P.W., Dirkx M.L., Breedveld S., Heijmen B.J. Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: comparison of different planning strategies. Med Phys. 2013;40:071704. doi: 10.1118/1.4808117. [DOI] [PubMed] [Google Scholar]
- 99.Martin D.A., Hruby G., Whitaker M.K., Foo K.Y. Constrained-beam inverse planning for intensity-modulated radiation therapy of prostate cancer patients with bilateral hip prostheses. J Med Imaging Radiat Oncol. 2012;56:703–707. doi: 10.1111/j.1754-9485.2012.02456.x. [DOI] [PubMed] [Google Scholar]
- 100.Cuaron J.J., Harris A.A., Chon B. Anterior-oriented proton beams for prostate cancer: A multi-institutional experience. Acta Oncol. 2015;54:868–874. doi: 10.3109/0284186X.2014.986288. [DOI] [PubMed] [Google Scholar]
- 101.Rana S., Cheng C., Zheng Y. Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison with volumetric-modulated arc therapy. J Appl Clin Med Phys. 2014;15:4611. doi: 10.1120/jacmp.v15i3.4611. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 102.Newhauser W.D., Giebeler A., Langen K.M., Mirkovic D., Mohan R. Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants? Phys Med Biol. 2008;53:2327–2344. doi: 10.1088/0031-9155/53/9/009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103.Bittner N., Butler W.M., Kurko B.S., Merrick G.S. Effect of metal hip prosthesis on the accuracy of electromagnetic localization tracking. Pract Radiat Oncol. 2015;5:43–48. doi: 10.1016/j.prro.2014.03.010. [DOI] [PubMed] [Google Scholar]
- 104.Boda-Heggemann J., Haneder S., Ehmann M. Stereotactic ultrasound for target volume definition in a patient with prostate cancer and bilateral total hip replacement. Pract Radiat Oncol. 2015;5:197–202. doi: 10.1016/j.prro.2014.08.008. [DOI] [PubMed] [Google Scholar]
- 105.Han S.C., Chung Y.E., Lee Y.H., Park K.K., Kim M.J., Kim K.W. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility. AJR Am J Roentgenol. 2014;203:788–795. doi: 10.2214/AJR.13.10980. [DOI] [PubMed] [Google Scholar]
- 106.Li H., Noel C., Chen H. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy. Med Phys. 2012;39:7507–7517. doi: 10.1118/1.4762814. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 107.Alongi F., Fodor A., Maggio A. Megavoltage CT images of helical tomotherapy unit for radiation treatment simulation: impact on feasibility of treatment planning in a prostate cancer patient with bilateral femoral prostheses. Tumori. 2011;97:221–224. doi: 10.1177/030089161109700215. [DOI] [PubMed] [Google Scholar]
- 108.Charnley N., Morgan A., Thomas E. The use of CT-MR image registration to define target volumes in pelvic radiotherapy in the presence of bilateral hip replacements. Br J Radiol. 2005;78:634–636. doi: 10.1259/bjr/28412864. [DOI] [PubMed] [Google Scholar]
- 109.Murphy C.T., Heller S., Ruth K. Evaluating toxicity from definitive radiation therapy for prostate cancer in men with inflammatory bowel disease: Patient selection and dosimetric parameters with modern treatment techniques. Pract Radiat Oncol. 2015;5:e215–e222. doi: 10.1016/j.prro.2014.09.004. [DOI] [PubMed] [Google Scholar]
- 110.White E.C., Murphy J.D., Chang D.T., Koong A.C. Low toxicity in inflammatory bowel disease patients treated with abdominal and pelvic radiation therapy. Am J Clin Oncol. 2015;38:564–569. doi: 10.1097/COC.0000000000000010. [DOI] [PubMed] [Google Scholar]
- 111.Kuban D.A., Tucker S.L., Dong L. Long-term results of the MD Anderson randomized dose-escalation trial for prostate cancer. Int J Radiat Oncol Biol Phys. 2008;70:67–74. doi: 10.1016/j.ijrobp.2007.06.054. [DOI] [PubMed] [Google Scholar]
- 112.Zietman A.L., Bae K., Slater J.D. Randomized trial comparing conventional-dose with high-dose conformal radiation therapy in early-stage adenocarcinoma of the prostate: long-term results from Proton Radiation Oncology Group/American College of Radiology 95-09. J Clin Oncol. 2010;28:1106–1111. doi: 10.1200/JCO.2009.25.8475. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113.Beckendorf V., Guerif S., Le Prise E. 70 Gy versus 80 Gy in localized prostate cancer: 5-year results of GETUG 06 randomized trial. Int J Radiat Oncol Biol Phys. 2011;80:1056–1063. doi: 10.1016/j.ijrobp.2010.03.049. [DOI] [PubMed] [Google Scholar]
- 114.Al-Mamgani A., van Putten W.L., Heemsbergen W.D. Update of Dutch multicenter dose-escalation trial of radiotherapy for localized prostate cancer. Int J Radiat Oncol Biol Phys. 2008;72:980–988. doi: 10.1016/j.ijrobp.2008.02.073. [DOI] [PubMed] [Google Scholar]
- 115.Dearnaley D.P., Sydes M.R., Graham J.D. Escalated-dose versus standard-dose conformal radiotherapy in prostate cancer: first results from the MRC RT01 randomised controlled trial. Lancet Oncol. 2007;8:475–487. doi: 10.1016/S1470-2045(07)70143-2. [DOI] [PubMed] [Google Scholar]
- 116.Seddon B., Bidmead M., Wilson J., Khoo V., Dearnaley D. Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. Radiother Oncol. 2000;56:73–83. doi: 10.1016/s0167-8140(00)00191-2. [DOI] [PubMed] [Google Scholar]
- 117.Michalski J. RTOG 0126: A phase III randomized study of high dose 3DCRT/IMRT versus standard dose 3DCRT/IMRT in patients treated for localized prostate cancer. http://www.rtog.org/ClinicalTrials/ProtocolTable/StudyDetails.aspx?study=0126 Available at: Accessed April 24, 2015.
- 118.McLaughlin P.W., Troyer S., Berri S. Functional anatomy of the prostate: Implications for treatment planning. Int J Radiat Oncol Biol Phys. 2005;63:479–491. doi: 10.1016/j.ijrobp.2005.02.036. [DOI] [PubMed] [Google Scholar]
- 119.McLaughlin P.W., Narayana V., Meirovitz A. Vessel-sparing prostate radiotherapy: dose limitation to critical erectile vascular structures (internal pudendal artery and corpus cavernosum) defined by MRI. Int J Radiat Oncol Biol Phys. 2005;61:20–31. doi: 10.1016/j.ijrobp.2004.04.070. [DOI] [PubMed] [Google Scholar]
- 120.Villeirs G.M., Van Vaerenbergh K., Vakaet L. Interobserver delineation variation using CT versus combined CT + MRI in intensity-modulated radiotherapy for prostate cancer. Strahlenther Onkol. 2005;181:424–430. doi: 10.1007/s00066-005-1383-x. [DOI] [PubMed] [Google Scholar]
- 121.Lee W. RTOG 0415: A phase III randomized study of hypofractionated 3DCRT/IMRT versus conventionally fractionated 3DCRT/IMRT in patients treated for favorable-risk prostate cancer. http://www.rtog.org/ClinicalTrials/ProtocolTable/StudyDetails.aspx?study=0415 Available at: Accessed April 24, 2015.
- 122.Rosewall T., Kong V., Vesprini D. Prostate delineation using CT and MRI for radiotherapy patients with bilateral hip prostheses. Radiother Oncol. 2009;90:325–330. doi: 10.1016/j.radonc.2008.11.015. [DOI] [PubMed] [Google Scholar]
- 123.Cox J. RTOG 9406: A phase I/II dose escalation study using three dimensional conformal radiation therapy for adenocarcinoma of the prostate. http://www.rtog.org/ClinicalTrials/ProtocolTable/StudyDetails.aspx?study=9406 Available at: Accessed April 22, 2015.
- 124.Pollack A. RTOG 0534: A phase III trial of short term androgen deprivation with pelvic lymph node or prostate bed only radiotherapy (SPPORT) in prostate cancer patients with a rising PSA after radical prostatectomy. https://www.rtog.org/ClinicalTrials/ProtocolTable/StudyDetails.aspx?study=0534 Available at: Accessed September, 2015.