Skip to main content
Pain Research & Management logoLink to Pain Research & Management
. 2017 Sep 27;2017:8560652. doi: 10.1155/2017/8560652

Effectiveness of Low-Level Laser Therapy in Reducing Orthodontic Pain: A Systematic Review and Meta-Analysis

Naira Figueiredo Deana 1, Carlos Zaror 2,3, Paulo Sandoval 2, Nilton Alves 4,
PMCID: PMC5635293  PMID: 29089818

Abstract

Objectives

To assess the effectiveness of low-level laser therapy (LLLT) in reducing orthodontic pain after the application of orthodontic force (OF).

Methods

A systematic search was conducted in the MEDLINE, EMBASE, Scopus, Cochrane Library, Web of Science, and EBSCOhost databases. The study included randomized clinical trials (RCT) which analysed the effectiveness of LLLT in reducing orthodontic pain assessed at 24 and 72 hrs after the application of OF. The risk of bias of the eligible trials was assessed using the Cochrane Collaboration's risk of bias tool. Standard mean difference was calculated and pooled by meta-analysis using random effect models.

Results

Of 467 identified articles, 20 RCT were finally included. In the risk of bias assessments, 13 studies presented a high risk, 5 an unclear risk, and 2 a low risk. The meta-analysis showed that in patients treated with laser versus placebo there was a difference in favour of LLLT in spontaneous pain 24 and 72 hrs after the installation of light archwires and spontaneous pain and chewing pain 24 and 72 hrs after the installation of elastomeric separators.

Conclusions

LLLT proved to be effective in promoting a reduction in spontaneous and chewing pain after the application of OF; however, the poor quality of the evidence requires these results to be treated with caution.

1. Introduction

Orthodontic treatment (OT) is essential for functional and aesthetic rehabilitation of the chewing apparatus [1]. The application of orthodontic force and consequent tooth movement promote remodelling of the alveolar bone around the tooth root [24]. The application of force to a tooth triggers a temporary inflammatory process mediated by a variety of inflammatory cytokines, with no pathological condition [5]. The tissular response implies initial vascular changes, followed by synthesis of prostaglandins, cytokines, and growth factors which finally activate tissular remodelling, characterised by osteoclastogenesis on the pressure side and osteogenesis on the tension side [15]. On the compression side, bone resorption is triggered by RANK signalling, present in osteoclast precursors, and RANKL, expressed in particular by osteoblasts [6].

Orthodontic pain is an unwanted side effect; it causes great concern among patients and may be responsible for their withdrawal from OT [7]. Pain is perceived as discomfort, dull pain, and hypersensitivity in affected teeth [8]; it tends to reach its peak after 24 hours, and a reduction is observed from the third day after fitting of the brace when the tissue recovery process commences [9, 10]. The painful sensation caused by tooth movement affects the patient's quality of life and interferes in his/her chewing and speech [10]. When a mechanical force is applied to the teeth, an inflammatory reaction is triggered in the periodontal tissue [11] resulting in the release of inflammatory mediators such as prostaglandins, T substance, histamine, and serotonin [12]. Previous studies have indicated that an increase in prostaglandin-E2 (PGE2) levels is related to the initial intensity of the pain, while an increase in interleukin-1 is related to pain occurring 24 hours after the application of orthodontic force [13].

Various methods have been proposed for reducing the discomfort caused by pain during tooth movement, such as the use of anti-inflammatory medication [14], acupuncture [15], and low-level laser therapy (LLLT) [16]; however, the secondary effects of the administration of nonsteroidal anti-inflammatory drugs (NSAID) may affect the rate of movement [14, 17]. LLLT has been used as an option for treating orthodontic pain as it is easy to apply and noninvasive, and there are few contraindications or side effects [16]. Some studies have reported that LLLT is able to control pain in orthodontic patients [7, 18]; however, other studies indicate that laser cannot produce analgesia in these patients [9]. The effectiveness of laser in reducing the pain caused by orthodontic treatment is therefore still undecided. The research question for this work was therefore as follows: Are the intensity and duration of the pain produced by the application of orthodontic force lower in patients who have received near infrared low-level laser therapy than in patients who received a placebo or no therapy of any kind? The aim of this study was to assess the effectiveness of near infrared low-level laser therapy in reducing orthodontic pain after the application of orthodontic force.

2. Materials and Methods

2.1. Eligibility Criteria

A systematic review of the published data was conducted in accordance with the Cochrane Handbook for the Systematic Review of Interventions and reported according to the guidelines of the Preferred Reporting Items of Systematic Reviews and Meta-Analysis (PRISMA) [19, 20].

The inclusion criteria were as follows: (1) randomized clinical trials which analysed the effectiveness of LLLT in reducing orthodontic pain compared with a control (no treatment of any kind) and/or placebo group (simulated pain treatment); (2) participants who received orthodontic treatment with elastomeric separators, canine retraction, and/or other orthodontic treatment; (3) studies which analysed the intensity and duration of pain using the Visual Analogue Scale (VAS), Numeric Rating Scale, or another type of questionnaire; (4) studies published in English.

The exclusion criteria were as follows: (1) studies of medically compromised patients; (2) studies that used high-level laser or red laser; (3) literature reviews, in vitro studies, case or letter reports, animal studies, and unpublished theses.

2.2. Sources of Information and Search Strategy

A systematic search was conducted up to May 2017 in the MEDLINE, EMBASE, Scopus, Cochrane Library, Web of Science, and EBSCOhost databases. The details of the search strategy used are given in Table 1. No limit date was applied in the search for articles. The search was complemented by a manual review of the references of the studies included.

Table 1.

Search strategy and results for PubMed, EMBASE, Cochrane Library, Web of Science, Scopus, and EBSCOhost.

Database Search strategy Results
MEDLINE/PubMed # 1: Low-level light therapy [Mesh] OR Low level laser therapy (Pubmed) OR Laser therapy (Pubmed) 76,795
# 2: Analgesia [Mesh] OR Discomfort (Pubmed) 76,088
# 3: Orthodontic (Pubmed) 62,754
# 4: # 1 AND # 2 AND # 3 398

EMBASE # 1: Low-level laser therapy 16,792
# 2: Pain AND tooth pain 6,559
# 3: Orthodontics 60,423
# 4: controlled clinical trial 597,953
# 5: # 1 AND # 2 AND # 3 AND # 4 15

Cochrane Library # 1: (Low-level light therapy) 366
# 2: (Pain) 27,139
# 3: (Orthodontics OR Orthodontic appliances, OR Orthodontic Anchorage procedures) 54
# 4: # 1 AND # 2 AND # 3 9

Web of Science # 1. low-level laser therapy AND Clinical trial AND Pain AND Orthodontics 8

Scopus # l. low-level laser therapy AND Clinical trial AND Pain AND Orthodontics 19

EBSCOhost ## 1: Low-level laser therapy OR Laser therapy OR LLLT 612
# 2: Pain 13,209
# 3: Orthodontic treatment 6,779
# 4: # 1 AND # 2 AND # 3 8

Titles and abstracts were selected independently by two investigators (N.F.D. and N.A.) to verify their eligibility. In cases of discrepancy, consensus was obtained by discussion or by consulting a third reviewer (P.S.). The references that appeared to fulfil the inclusion criteria were reviewed in full text by the same reviewers (N.F.D. and N.A.).

The data from each article selected were analysed to obtain sample size, sex, age range, laser used, wavelength, output power, spot size, number of application points, treatment time, days of LLLT application, total energy, energy density, study design, pain evaluation method, pain evaluation interval, and the principal results found for the LLLT group and the control/placebo group (event frequency, mean, and standard deviation of pain scores).

2.3. Assessment of Risk of Bias

Two review authors (N.F.D. and N.A.) independently assessed the risk of bias of the eligible trials according to the Cochrane Collaboration's risk of bias tool [19]. In cases of discrepancy, consensus was obtained by consulting a third reviewer (C.Z.). The domains assessed were (1) random sequence generation; (2) allocation concealment; (3) blinding of participants; (4) blinding of personnel; (5) blinding of outcome assessment; (6) incomplete outcome data; (7) selective reporting; (8) other biases (baseline imbalance, similarity in using cointerventions between groups, and inadequate statistical analysis). The potential risk of bias for each study was classified as high, unclear, or low.

2.4. Summary of Findings

We used the principles of the GRADE system to assess the overall quality of the body of evidence associated with the main outcomes and we constructed a “Summary of Findings” (SoF) table using the GRADEpro GDT software (http://gdt.guidelinedevelopment.org). The GRADE approach appraises the quality of a body of evidence based on the extent to which one can be confident that an estimate of effect or association reflects the item being assessed. We assessed the quality of the body of evidence with reference to the overall risk of bias of the included studies, directness of the evidence, inconsistency of the results, precision of the estimates, risk of publication bias, and magnitude of the effect [20]. Depending on the seriousness, the quality of the evidence can be downgraded by one or two levels for each aspect. We categorised the quality of the body of evidence for each of the primary outcomes as high, moderate, low, or very low.

2.5. Data Synthesis

The main outcome was pain assessed at 24 hrs and 72 hrs. We pooled studies that compared laser therapy with a placebo. In studies that used protocols with different irradiation doses, the protocol with the lowest doses was included in the meta-analysis. Results reported as continuous data with standard mean difference (SMD) were calculated and pooled by meta-analysis. The SMD allowed us to combine data from studies using different pain scales, such as VAS and Numeric Rating Scale [19]. For all measures, forest plots were constructed showing the summary and 95% confidence interval (CI) estimated in the meta-analyses, together with results from individual studies. We used a random effect model (DerSimonian-Laird method), as we expected variation in effects due to differences in study populations, pain scales, and methods. We combined different study designs (parallel designs and split-mouth designs) using the generic inverse variance method [19, 21].

Heterogeneity among studies was evaluated using the I2 statistical categorisation as follows: <30% not important; 30%–50% moderate; 50%–75% substantial; 75%–100% considerable [19, 21]. A subgroup analysis was performed according to type of orthodontic force used, since this could be an important source of heterogeneity. The software used was Review Manager 5.3 (Cochrane IMS, Copenhagen, Denmark).

3. Results

3.1. Study Selection

A flowchart of the article selection process for each stage of the review is presented in Figure 1. The search identified 457 references. After excluding duplicates and reviewing titles and abstracts, 32 articles were evaluated in full text. Subsequently, 12 potentially relevant studies were excluded and one was identified by hand search. Twenty RCT were finally included.

Figure 1.

Figure 1

Flowchart of systematic literature review.

3.2. Study Characteristics

The parameters used in the studies are analysed in Table 2. We observed that in many studies the irradiation parameters were not presented; in general, however, sufficient information was given to enable them to be calculated.

Table 2.

Summary of laser irradiation parameters used in each study.

Authors Subjects
M : F
Age Type of laser/λ/mode SP ED (J/cm2) OP (mW) Points t Frequency of laser therapy TE (J) Study design LLLT is
effective in
reducing pain
Elastomeric separators

Abtahi
et al. [33]
29/24 : 5 12–22 GaAs 904 nm, pulsed mode 0.38 cm2 NI 200 mW 4 points: (cervical and radicular)
2 vestibular
2 lingual
30 s 0, 1, 2, 3, and 4 1.5/point
6/tooth
Single blind, split-mouth No

Almallah
et al. [28]
36 12–26 GaAlAs 830 nm 7 mm 16/tooth 100 mW 8 lingual, 8 palatal 28 s/area Single dose and
0, 1
NI Single blind, split-mouth Yes

AlSayed Hasan
et al. [30]
13/3 : 9 Mean age
18.16
GaAlAs 830 nm,
continuous mode
NI 2.25/tooth 150 mW 2 points: mesial and distal, cervical third 15 s/point Single dose 2/point
4/tooth
Single blind, split-mouth No
13/4 : 7 Mean age
18.30
GaAlAs 830 nm,
continuous mode
NI 9/tooth 150 mW 2 points: mesial and distal, cervical third 60 s/point Single dose 8/point
16/tooth
Single blind, split-mouth No

Artés-Ribas
et al. [26]
20/06 : 14 19–33.8 GaAlAs 830 nm
continuous mode
0.4 cm2 5/point
30/tooth
100 mW 6: 3 vestibular, 3 lingual 120 s/tooth Single dose 2/point,
12/tooth
Single blind, split-mouth Yes

Bicakci
et al. [31]
19/08 : 11 13.5–14.5 GaAlAs 820 nm 0.0314 cm2 7.96/point
31.84/tooth
50 mW 4: mesiobuccal mesiopalatal
distobuccal distopalatal
5 s/point 0, 24 h 0.25/point
1/tooth
Single blind, split-mouth Yes

Eslamian
et al. [32]
37/12 : 25 11–32 GaAlAs 810 nm, continuous mode NI 2/point 100 mW 10: 5 buccal, 5 palatal 20 s/point 0, 24 h NI Single blind, split-mouth Yes

Farias
et al. [24]
30 18–40 GaAlAs 810 nm 0.028 cm2 2/point
6/total
100 mW 3 points: interdental
papilla, distal, near the apex
15 s/point Single dose 6/tooth Double blind,
split-mouth
Yes

Furquim
et al. [29]
79 13–34 GaAlAs 808 nm NI 80/tooth NI NI NI Single dose 6/tooth Single blind, split-mouth No

Lim
et al. [25]
39 21–24 GaAlAs 830 nm NI NI 30 mW 1: middle third 15 s; 30 s; 60 s/tooth 0, 1, 2, 3, 4, and 5 0.45; 0.95; 1.8 Double blind, split-mouth No

Marini
et al. [22]
120/64 : 56 20–25 GaAs 910 nm
superpulsed mode
0.5 cm2 NI 160 mW 2: cervical third (buccal and lingual) 340 s/total Single dose 54.4/total energy Double blind, parallel Yes

Nóbrega
et al. [27]
60/22 : 38 12–26 GaAlAs 830 nm 2 mm 1/point
5/total
40.6 mW 4 points (vestibular) 25/point
125 s total
Single dose 5/tooth Double blind, parallel Yes

Qamruddin
et al. [23]
88/28 : 60 13–30 GaAlAs 940 nm,
continuous mode
NI NI 200 mW 3 points buccally: mesial, distal middle 20 s/point Single dose 4/point
12/tooth
Single blind, split-mouth Yes

Archwire placement (initial stage)

Bayani
et al. [34]
40 14–21 GaAlAs 810 nm 0,28 3,6/tooth 200 mW 6: cervical, middle, apical (vestibular and lingual) 30 s/tooth Single dose 6/tooth Parallel Yes

Deshpande
et al. [36]
30 16–25 GaAs 904 nm 5 mm NI 10 W Lingual and buccal: middle third region 120 s/side Single dose NI Single blind, parallel Yes

Tortamano
et al. [35]
60/18 : 42 12–18 GaAlAs 830 nm NI 5/tooth 30 mW 10: 2 apical, 1 middle third, 2 cervical (palatal, lingual) 16/point Single dose NI Double blind, parallel Yes

Archwire placement (final stage)

Domínguez and
Velásquez [37]
59/19 : 40 NI GaAlAs 830 nm 600 μm 80/point 100 mW 2: 1 vestibular, 1 palatal 44 s/tooth Single dose 4.4/tooth Single blind, split-mouth Yes

Canine retraction

Angelieri
et al. [9]
12 Mean age 12.66 ArGaAl 780 nm NI 5/point 20 mW 10 points: 5 buccal and 5 lingual 10 s/point 0, 3, and 7 0.2/point
2/tooth
Single blind, split-mouth No

Dalaie
et al. [39]
12/3 : 9 Mean age 20.1 GaAlAs 880 nm,
continuous mode
NI 5/point 100 mW 8 points:
4 buccally
4 lingually
10 s/point 1, 3, 7, 30, 33, 37, 60, 63, and 67 NI Double blind, split-mouth No

Doshi-Mehta and Bhad-Patil [38] 20/8 : 12 12–23 GaAlAs 800 nm,
continuous mode
NI 5/total 0.7 mW 2: 1 buccal
and 1 lingual
10 s/point 0, 3, 7, and 14 (first month and thereafter every 15 days) 8/tooth Single blind, split-mouth Yes

Heravi
et al. [40]
20/03 : 17 15–31 GaAlAS 810 nm, continuous mode 0.28 cm2 21.4/point 200 mW 10 points: 5 buccal and 5 lingual 30 s/point 0, 4, 7, 11, 15, 32, 35, 39, 43, and 56 6/point
60/tooth
Single blind, split-mouth No

M: male, F: female, λ: wavelength, OP: output power, t: time, TE: total energy, ED: energy density, SP: spot size, OT: orthodontic treatment, and NI: not informed.

3.2.1. Elastomeric Separators

Twelve RCT analysed pain in patients subjected to OF with elastomeric separators [2233]; in eight, a reduction in pain intensity was observed [2224, 2628, 31, 32]. Ten articles described laser application under a split-mouth design [2326, 2833] and two were parallel clinical trials [22, 27].

3.2.2. Archwire Placement

Three studies analysed the analgesic effect of LLLT on orthodontic pain after the installation of light (initial) archwires [3436]. All the studies reported reduced pain with the use of laser and used parallel design.

One study examined the effect of LLLT on pain in the final archwires [37]; laser was successful in reducing pain. This study used a split-mouth design.

3.2.3. Canine Retraction

Four RCT assessed the effect of LLLT on orthodontic pain during canine retraction [9, 3840]; pain reduction was observed in only one study [38]. All used split-mouth design.

3.2.4. Pain Assessment and Principal Findings of Studies

The pain assessments and the main findings reported are summarised in Table 3. The Visual Analogue Scale (VAS) was the method used for pain assessment in 16 studies [9, 22, 2434, 37, 38, 40], three studies used the Numeric Rating Scale [23, 35, 36], and one used the Wong-Baker Faces Pain Rating Scale [39]. VAS was originally proposed by Huskisson (1974) for quantifying pain. It takes the form of a line 10 cm long marked with a scale of 0 to 10 to indicate the pain level experienced, with 0 representing absence of pain and 10 intense pain [9]. Because it is easily applied and understood, VAS is used in many studies. In the articles analysed in our study, pain was measured from 5 minutes up to 120 hours after the application of orthodontic force. The pain reached a peak within 24 or 48 hours after application and reduced on the third day. Of the 20 studies included in the qualitative analysis, 13 (65%) reported finding a significant reduction in pain [2224, 2628, 31, 32, 3438].

Table 3.

Description of the principal findings for the control group and the group irradiated with LLLT, with pain assessment method and interval after orthodontic activation.

Author Evaluation method Evaluation interval after start of orthodontic treatment Outcomes Evaluation of pain level
Laser group (LG) Control group (CG)/placebo
Abtahi
et al. [33]
VAS Pain levels were measured for 5 days No statistically
significant difference between the
placebo and
experimental groups
(1) Days 1, 3, 4, and 5: no statistically
significant difference between groups.
(2) Day 2: pain level significantly
lower in LLLT group (P = 0.009).
(1) The maximum level of pain
was recorded 1 day after placement
of separators and gradually
declined until day 5.

Almallah
et al. [28]
VAS 1, 6, 24, 48, and 96 hours LLLT reduced
the orthodontic pain
caused by elastomeric separators
(1) Peak pain occurred after 24 hrs in the group which received a single irradiation
and after 48 hrs in the group which received double irradiation.
(2) No differences were found between pain intensity with single or double irradiation.

AlSayed Hasan
et al. [30]
VAS 1, 6, 12, 24, 48, and 72 hours A single application
of LLLT was not
effective in reducing
pain caused by
elastomeric separators
(1) Peak pain occurred 24 hrs after application of orthodontic force in both the placebo
group and the experimental group.
(2) Both LLLT protocols (4 J and 16 J) failed to reduce pain.

Angelieri
et al. [9]
VAS 12, 24, 48, and 72 h after LLLT
Repeated in the 2nd month
The laser protocol
used in the study
was not effective
in reducing pain
sensitivity
(1) No statistically significant difference in pain reduction was found between the
irradiated and the control sides.

Artés-Ribas
et al. [26]
VAS 5 m, 6 h, 24 h, 48 h, and 72 h The LLLT parameters
used can reduce
pain in patients
following placement
of orthodontic
rubber separators
(1) Significant pain reduction as compared with
the control/placebo side (P = 0.0001).
(1) Peak pain in 24 hours.
(2) Pain reached its peak after 6–24
hours and decreased thereafter
between 48 and 72 h.

Bayani
et al. [34]
VAS 2 h, 6 h, bedtime, 24 h, 2, 3, and 7 days A single irradiation
of LLLT was effective
in reducing pain
following initial
archwire placement
(1) Peak pain occurred 24 hrs after application of orthodontic force.
(2) Low power red laser could not be recommended for pain control following
placement of orthodontic appliances.
(3) VAS presented similar mean values to those in patients treated with ibuprofen,
LLLT, and bite wafer.

Bicakci
et al. [31]
VAS 5 m, 1 h, 24 h Significant reduction in
pain and PGE2 after
24 hours in the
group irradiated
with LLL
(1) Significant pain reduction was observed
with laser treatment 24 h after application.
Significant differences in pain level were observed between LG and CG after 24 h (P = 0.001).
(2) The mean PGE2 levels showed a gradual decrease. (3) Significant differences in pain level were observed between LG and CG after 1 and 24 h (P = 0.001 and P = 0.001, resp.)
(1) The mean PGE2 levels were
significantly elevated.

Dalaie
et al. [39]
Wong-Baker
Faces Pain Rating Scale was utilized
Days 1, 33, and 63 No solid evidence was
found to support
the effectiveness of
laser for pain
reduction
(1) There was no statistically significant difference in pain reduction
between LG and CG.

Deshpande
et al. [36]
Scale used by Tortamano et al. modified (Harazaki + Number Rating Scale) 1, 24, 48, and 72 h after LLLT LLLT reduced pain
duration and intensity
fixed orthodontic
therapy patients
(1) Peak pain occurred 1 day after
application of orthodontic force.
(2) The pain disappeared 3 days after
application of orthodontic force.
(1) Peak pain occurred 2
days after application of
orthodontic force.
(2) The pain disappeared 3
days after application of orthodontic
force.

Domínguez and
Velásquez [37]
VAS 2 h, 6 h, and 24 h
Days: 2, 3, and 7
LLLT is effective
for pain reduction throughout
orthodontic treatment
(1) Pain was significantly less in the LLLT group at all the intervals
measured (P < 0.00001).
(2) Peak pain in 24 hours.

Doshi-Mehta
and Bhad-Patil [38]
VAS Days: 1, 3, and 30 Pain level reduced significantly with
the use of LLLT
(1) Significant pain reduction on days 3 and
30 as compared with the first day (P = 0.0001 and P = 0.0000, resp.).
(2) Significant pain reduction in the irradiated
group as compared with the CG on days 3 and
30 (P = 0.0000, P = 0.0000, resp.).
(1) Significant pain reduction
after 30 days as compared with
day 1 (P = 0.0016).

Eslamian
et al. [32]
VAS 6 h, 24 h, and 30 h
Days: 3, 4, 5, 6, and 7
LLLT reduced pain perception in the
first 3 days after
orthodontic separation
(1) After 6, 24, and 30 h and on day 3
the pain was significantly less in LG (P = 0.031, P = 0.014, P = 0.043, and P = 0.047, resp.).
(2) Pain intensity peaked at 6 and 30 h
after placing elastomeric separators.
(3) Greatest pain was recorded in the mandible
at 24 and 30 h.
(1) Pain intensity peaked between
6 and 30 h after placing
elastomeric separators.
(2) Greatest pain was recorded
in the mandible at 24 h.

Farias
et al. [24]
VAS 5 min., 24 and 120 hours AlGaAs diode LLLT
(810 nm) is an
effective therapeutic method to
control or reduce
pain in the early
stages of orthodontic treatment
(1) After 24 h a 13.89% reduction in pain
was promoted.
(2) LLLT (810 nm) was effective in pain
reduction from the first 24 hours up to the
fifth day (120 hours) after separator placement.
(3) Lower pain intensity was recorded in the
group treated with LLL after 5 minutes,
24 hours, and 120 hours.
(1) After 24 h there was a 44.39%
increase in pain.
(2) A significant pain reduction was
observed 120 hours after
installation of elastomeric
separators.

Furquim
et al. [29]
VAS 6 h, 12 h
Days: 1, 2, and 3
LLLT did not
produce significant effects on the
perception of pain caused by
orthodontic separation
(1) The pain peak perceived by patients occurred between 12 hours and 1 day.

Heravi
et al. [40]
VAS Days 0, 4, 7, 11, 15, 28, 32, 35, 39, 43, and 56 LLLT with the parameters used in
this studio did
not influence the
pain perceived
by the patients
(1) No significant difference was found in VAS scores between the laser and
the placebo groups.

Lim
et al. [25]
VAS Before and after LLLT for 5 days No statistically significant
difference between
the placebo
and experimental groups
(1) Pain intensity was lower in the experimental group than in the placebo group;
however, no statistically significant difference was observed.

Marini
et al. [22]
VAS 0, 12, 24, 36, 48, 72, and 96 h LLLT is effective
in reducing pain intensity and
duration
(1) No significant difference between the arches.
(2) Statistically significant differences between groups at 12, 24, 36, 48, 72, and 96 h
(P = 0.0001); the mean VAS values of the laser groups were lower than placebo and
control groups.
(3) The pain never disappeared in 10% of subjects in the laser group, 70% of subjects
in the placebo group, and 80% of subjects in the CG.
(4) No significant differences were found between the placebo and CG.
(5) The intensity and duration of pain were lower in the LG than in the
placebo and CG.
(6) The intensity of pain was lower in the placebo group than the CG.

Nóbrega
et al. [27]
VAS 2, 6, 24, 72, 120 hours Laser irradiation controlled the
original pain
when the elastomeric separators were fitted
(1) The levels of spontaneous and
occlusion pain were significantly lower
in patients treated with LLL as compared
with the placebo group at 2, 6,
and 24 hours, and 3 and 5 days.
(2) Two hours after installation of the
elastomeric separators, 10% of the patients
presented spontaneous pain and 16.7%
occlusion pain. After 24 hours, 50%
of the patients presented spontaneous
pain and 66.7% occlusion pain. After
5 days, 10% of the patients presented
spontaneous pain and 23.3% occlusion pain.
(1) Two hours after installation of the
elastomeric separators, 63.3% of the
patients presented spontaneous pain and
70% occlusion pain. After 24 hours,
86.7% of the patients presented
spontaneous pain and 100%
occlusion pain. After 5 days,
30% of the patients
presented spontaneous pain
and 60% occlusion pain.

Qamruddin
et al. [23]
Numerical Rating Scale 24 hours, for the next 7 days A single dose of LLLT reduced spontaneous and chewing pain (1) Peak pain in 24 hours.
(2) Significant reduction in the intensity of
chewing pain on the third day.
(3) Lesser intensity of spontaneous and chewing
pain in the LG as compared with the CG on days 1, 2, 3, 4, 5, 6, and 7.
(4) Although significantly less, some degree
of pain was present even on day 7.
(1) Peak pain in 24 hours.
(2) The highest intensity of pain was
associated with chewing on the
placebo side.
(3) Although significantly less,
some degree
of pain was present
even on day 7.

Tortamano
et al. [35]
Harazaki + Numeric Rating Scale Pain start, most painful day, and end of pain LLLT efficiently controls pain caused by the first archwire (1) Lower intensity of oral pain compared to the placebo and control groups.
(2) Lower intensity of pain on the day of greatest pain compared to the placebo
and control groups.
(3) No differences found between maxilla and mandible.
(4) The pain ceased more quickly in the experimental group (day 3) than in the placebo
and control groups.
(5) LLLT can control pain from placement of the first archwire.
(6) The day of greatest pain was similar for both groups. It occurred between 24
and 48 hours
after activation of the orthodontic appliance.
(7) The patients in the experimental group generally report oral pain only
on touching, while in the control and placebo groups they reported
continuous and also chewing pain.

3.3. Risk of Bias

The results of the risk of bias assessments of the studies included in this systematic review are shown in Figure 2. Of a total of 20 studies, 13 presented high risk of bias [9, 23, 24, 26, 2830, 32, 34, 3638, 40], five presented unclear risk [25, 31, 33, 35, 39], and two presented low risk [22, 27]. “Blinding of personnel” was the principal risk of bias observed in studies, with ten studies where the operators were not blinded [9, 23, 26, 2830, 34, 37, 38, 40]; another four studies stated that the operators were blinded but gave no details of how this was done [3133, 36]. Although only randomized studies were included, it was observed that two studies did not carry out “random sequence generation” correctly [24, 32], and five studies did not describe how the randomization sequence was generated [9, 29, 33, 36, 40]. Only three studies declared consistently how “allocation concealment” was done [22, 25, 27]; in three studies, the allocations could be predicted [23, 24, 32]; in one study, the authors declared that the sequence was concealed but gave no information on how the “allocation concealment” was effected [30], and the other studies did not offer sufficient information to judge the concealment of the randomization sequence. “Blinding of participants” and “blinding of outcome” were carried out in all studies except one [34], in which the authors declared that blinding was impossible due to the different pain management approaches employed in their study. One study presented “incomplete outcome data” due to the withdrawal of a large number of participants, especially in one of the groups [29]; two studies gave no information on losses [36, 40] and one declared only 10% losses but did not state which groups lost participants, making it impossible to assess whether the lack of patient follow-up had any impact on the results [34]. Six studies did not present sufficient information to judge “selective reporting” [9, 25, 33, 35, 37, 38] and one study did not report all the results declared in the methodology [36].

Figure 2.

Figure 2

Risk of bias summary: authors' judgments about each risk of bias item for studies included.

3.4. Effectiveness of LLLT (Near Infrared) in Reducing Orthodontic Pain

3.4.1. Spontaneous Pain

Six studies reported sufficient data to assess the intensity of spontaneous pain after 24 hrs; these were divided into two subgroups according to the different types of orthodontic force (Figure 3). In the analysis of spontaneous pain 24 hrs after the installation of elastomeric separators, four studies with low quality of evidence were compared, of which three assessed pain by VAS and one by Numeric Rating Scale. Less intensity of pain was observed in patients treated with laser (near infrared) than in those with placebo (SMD −0.76; 95% CI −1.19 to −0.33; I2 = 70%). The comparison of spontaneous pain 24 hrs after the installation of light archwires between patients treated with laser versus placebo showed a difference in favour of LLLT (SMD −2.09; 95% CI −4.10 to −0.09; I2 = 89%). The quality of evidence was also judged to be low, meaning that we had low confidence in the estimate of effect. The overall assessment was significantly in favour of LLLT (near infrared) (SMD −1.11; 95% CI −1.69 to −0.53; I2 = 38.6%).

Figure 3.

Figure 3

Forest plot of pooled standard mean difference in spontaneous pain at 24 hours.

The findings for spontaneous pain after 72 hrs were compared in four studies (Figure 4); two used the Numeric Rating Scale and two used VAS. Three studies with low quality of evidence presented sufficient data for analysing spontaneous pain after the installation of elastomeric separators: a significant reduction in pain intensity was observed in the groups treated with laser (near infrared) as compared to placebo (SMD −0.54; 95% CI −0.91 to −0.17; I2 = 58%). One study with low quality of evidence compared the spontaneous pain 72 hrs after the installation of light archwires in patients treated with laser versus no treatment: the pain intensity was lower in patients treated with laser than in patients with no treatment (SMD −1.54; 95% CI −2.57 to −0.51). In the overall assessment, a significant reduction in pain intensity was observed in the laser-irradiated group compared with the placebo group (SMD −0.65; 95% CI −1.06 to −0.24; I2 = 69%).

Figure 4.

Figure 4

Forest plot of pooled standard mean difference in spontaneous pain at 72 hours.

3.4.2. Chewing Pain

Three studies assessed pain intensity during chewing 24 and 72 hrs after the installation of elastomeric separators (Figures 5 and 6). Two of these used VAS and one used the Numeric Rating Scale. The intensity of chewing pain 24 hrs after the installation of elastomeric separators was less in the laser-treated group than the placebo group (SMD −0.99; 95% CI −1.28 to −0.70; I2 = 9%); a similar pattern was observed after 72 hrs (SMD −0.68; 95% CI −1.03 to −0.32; I2 = 34%). For both outcomes the quality of evidence was judged to be low, meaning further research is very likely to have an important impact on our confidence in the estimate of effect.

Figure 5.

Figure 5

Forest plot of pooled standard mean difference in chewing pain at 24 hours.

Figure 6.

Figure 6

Forest plot of pooled standard mean difference in chewing pain at 72 hours.

3.4.3. Quality of Evidence Summary

All the studies included were randomized controlled trials. However, methodological issues limited the overall quality of evidence. We downgraded their quality mainly due to the high risk of bias associated with selection bias, performance bias, and selective report bias. Moreover, the low number of participants for some outcomes led to additional downgrading for imprecision of the effect estimate. Selection bias was judged as high risk of bias due to the use of inadequate methods to generate the random sequence and lack of allocation concealment. The performance bias was downgraded in some studies because it was not possible to blind the personnel; however, all studies included in the analysis reported that the outcome assessor was blinded. Only one study presented selective reporting. Our final assessment was that all the outcomes presented low quality of evidence (Table 4).

Table 4.

GRADE quality evidence.

Outcomes N. of participants
(studies)
Quality of the evidence
(GRADE)
Anticipated absolute effects
Risk with placebo Risk difference with pain laser
Spontaneous pain 24 h, elastomeric separators 203 participants
(4 RCTs)
⨁⨁◯◯
lowa
SMD 0.76 SD lower  
(1.19 lower to 0.33 lower)

Spontaneous pain 24 h, archwire placement 60 participants
(2 RCTs)
⨁⨁◯◯
lowb
SMD 2.09 lower  
(4.1 lower to 0.09 lower)

Spontaneous pain 72 h, elastomeric separators 185 participants
(3 RCTs)
⨁⨁◯◯
lowc
SMD 0.54 lower  
(0.91 lower to 0.17 lower)

Spontaneous pain 72 h, archwire placement 20 participants
(1 RCT)
⨁⨁◯◯
lowd
SMD 1.54 lower  
(2.57 lower to 0.51 lower)

Chewing pain 24 h, elastomeric separators 160 participants
(3 RCTs)
⨁⨁◯◯
lowe
SMD 0.99 lower  
(1.28 lower to 0.7 lower)

Chewing pain 72 h, elastomeric separators 160 participants
(3 RCTs)
⨁⨁◯◯
lowe
SMD 0.68 lower  
(1.03 lower to 0.32 lower)

CI, confidence interval; SMD, standardised mean difference; GRADE, working group grades of evidence: high quality: we are very confident that the true effect lies close to that of the estimate of the effect; moderate quality: we are moderately confident in the effect estimate; the true effect is likely to be close to the estimate of the effect, but there is a possibility that it is substantially different; low quality: our confidence in the effect estimate is limited; the true effect may be substantially different from the estimate of the effect; very low quality: we have very little confidence in the effect estimate, the true effect is likely to be substantially different from the estimate of effect; explanations: athe evidence was downgraded by two levels because of very serious concern regarding the risk of bias; one study had high risk in random sequence generation, two studies did not report information regarding allocation concealment, and two studies had a high risk of performance bias; bthe evidence was downgraded by one level because one study had high risk regarding selective report and small number of participants; cthe evidence was downgraded by two levels because of very serious concern regarding the risk of bias; one study had high risk in random sequence generation, two studies did not report information regarding allocation concealment, and one study had a high risk of performance bias; dthe evidence was downgraded by one level because one study had high risk regarding selective report and one level because it is single study (indirectness); ethe evidence was downgraded by two levels because of very serious concern regarding the risk of bias; one study did not report information regarding allocation concealment and two studies had a high risk of performance bias.

4. Discussion

4.1. Summary of the Evidence

Tooth movement is dependent on a painful, inflammatory adaptation of the alveolar process [17]. The pain caused by tooth movement is a constant concern among patients. Pain perception varies considerably from patient to patient; it is a highly subjective sensation and consequently very difficult to quantify in scientific investigation [41].

Due to the inflammatory nature of orthodontic pain, nonsteroidal anti-inflammatory drugs (NSAID) have been considered the gold standard for controlling pain in orthodontic patients [4], administered when the patient suffers unbearable pain. NSAID inhibits the synthesis of prostaglandins, which are important mediators of pain induction [4]. It should be noted that the use of these drugs is associated with gastrointestinal problems, thrombocytopenia, skin rashes, renal insufficiency, hypertension, and headaches [8]. LLLT presents no serious side effects such as are related to NSAID [22]; furthermore, some studies have shown that LLLT is effective not only in reducing orthodontic pain but also in increasing the rate of tooth movement in canine retraction [7, 38, 42]. Domínguez-Camacho and Velasquez-Cujar [43] indicate that LLLT reduces the average time of treatment by 30% and is effective in accelerating dental movement not just in a specific phase of treatment. In a randomized clinical trial, Bayani et al. [34] compared the effects of ibuprofen, low-level red laser (660 nm), low-level infrared laser (810 nm), and bite wafers in orthodontic pain management. These authors report that low-level infrared laser (810 nm) was the most effective strategy for pain relief following initial wire installation and can be considered an alternative to ibuprofen. LLLT promotes local effects on inflammation less than 24 hours after irradiation, as well as reducing levels of PGE2, tumour necrosis factor, plasminogen activator, and COX-2 expression [10]. One of the mechanisms by which laser reduces pain is by producing an alteration in the conduction of action potentials in the peripheral nerves through the generation of varicosities which reduce the speed of fast axonal flow and reduce the mitochondrial membrane potentials, resulting in reduced availability of ATP and neurotransmission failure in Aδ and C nociceptor fibres [44]. According to Montesinos [45], another way in which pain reduction is promoted is through stimulation of beta-endorphin production, a natural mediator produced by the organism which reduces pain. LLLT also inhibits the release of arachidonic acid, which acts on damaged cells to generate metabolites which interact with pain receptors [46].

When using laser, it is important to choose the most appropriate wavelength for each disease [47]. Laser penetration of the tissues is directly related to wavelength [48]. A wavelength of 830 nm presents the deepest penetration, able to reach the cortical and alveolar bone tissues; it is more effective than wavelengths between 620 and 670 nm [49]. Because red and infrared laser are indicated in different situations [47], we consider it important to analyse their effects separately; in the present investigation, therefore, we only considered RCT with low-level laser (near infrared) at wavelengths between 780 nm and 940 nm. Red laser has weaker penetration, mainly due to the absorption mechanism by which it interacts with biological tissue; it is therefore indicated for superficial lesions, such as tissue repair (healing and local drainage). Infrared laser by contrast achieves deeper penetration due to its interaction through changes of polarity in the biomembranes. Because of its wavelength, infrared laser has been the treatment of choice for promoting immediate and temporary analgesia, acting on the cell membrane to cause hyperpolarization, that is, a photo-physical change as a result of the light-cell biological interaction [47]. Endorphin synthesis and the action potential of neural cells increase, whereas the amount of bradykinin as well as the activity of the C-fibres driving the pain stimuli decreases [50], resulting in relief of painful symptoms [46]. Of the 13 studies which found pain reduction with LLLT, ten used a wavelength between 800 and 830 nm and three between 910 and 940 nm. In the seven studies in which no pain reduction was observed, five used wavelengths between 780 and 830 nm and two used wavelengths between 880 nm and 940 nm. Although the results are not unanimous, studies which used wavelengths between 800 and 830 nm reported a greater analgesic capacity than studies which used 904–940 nm, corroborating the findings of Yamaguchi et al. [51]. Some researchers report that when pulsed mode is used, multiple photo-dissociation events can occur, promoting greater penetration by the laser light than in continuous mode where the number of dissociations may be much smaller [52]. Some studies reveal that pulsed light promotes better tissue repair and reduces the behavioural manifestations of somatic pain when compared with continuous wave [53, 54]. According to Antczak-Bouckoms et al. [55], the decision to choose split-mouth design will depend on the nature of the disease and the effect of the treatment. Some authors state that split-mouth design allows better pain evaluation since it eliminates interindividual variation resulting from sex, age, and pain perception [23]. A great advantage of split-mouth design is the smaller sample size required compared to parallel studies, since each patient acts as his own control [56]. When split-mouth design is used, the intervention sites in each patient must be uniform; this is not usually a problem in orthodontics, since intact dentitions are more often available, meaning that comparable sites are more feasible [57]. It must be noted that the lack of uniformity between sites in participants may introduce a selection bias, since interventions may be applied in sites with different baseline characteristics [57]. Another advantage of studies with split-mouth design is that the loss or withdrawal of participants does not create an imbalance between groups for analysis of the results; however, the loss/withdrawal rate cannot be so high that it affects the result of the study. One possible disadvantage of split-mouth as compared to parallel design in studies using laser irradiation is that operator blinding is more difficult, since the laser and the simulation (placebo) are generally applied in the same session, and this introduces a bias into the study. In our investigation, we observed that 15 studies (75%) used split-mouth design; of these, only three reported a double-blind study [24, 25, 39].

Only two studies had low risk of bias [22, 27]; five studies presented an unclear risk [25, 31, 33, 35, 39] and the other 13 presented a high risk [9, 23, 24, 26, 2830, 32, 34, 3638, 40]. “Allocation concealment” and “blinding of personnel” were the main weaknesses in study execution, and only 30% reported correct application of this precaution [22, 24, 25, 27, 35, 39]. The fact that the majority of studies presented a high or unclear risk of bias means that the results must be interpreted with caution.

LLLT single application proved effective for pain reduction in ten studies [2224, 2628, 3437], while in three studies pain was reduced with two applications of LLLT [28, 31, 32], and in one study LLLT was effective after four applications [38]. Almallah et al. [28] carried out a study comparing single dose with double dose and found no differences in pain reduction. We observed that there are no studies in the literature reporting the “ideal” number of LLLT applications; however, we can say that a single dose after the application of OF proved sufficient to reduce pain.

The pain evaluation method used in 80% of the studies was VAS. According to Farias et al. [24] and Bicakci et al. [31], in patients treated with LLLT, significant pain reduction was observed 24 hours after the application of orthodontic force. Orthodontic pain begins two hours after orthodontic activation [35] and tends to be more severe after 6–24 hours [23, 26, 2830, 3234, 36, 37]; it presents a reduction after two days [26], three days [27, 35, 36], or five days [24, 33]. According to the literature, pain is more intense in patients in the control/placebo group [2224, 2628, 31, 32, 34, 35, 37, 38]. Oral pain is less intense in patients treated with LLLT [35]. Marini et al. [22] indicate that in the LLLT group the score on the VAS scale was always close to zero, with a maximum of 3.5, while the control group presented a minimum of 3.0 shortly after activation and a maximum of 6.5 at 36 hours after orthodontic activation. The pain intensity described by orthodontics patients varied according to the type of OF applied. When elastomeric separators were used, the highest spontaneous pain measured by VAS (0–10) after 24 hrs was 5.25 for the LLLT group [33], 4.71 for the placebo group [24], and 6.1 for the control group [22]. The highest pain level found in participants who used elastomeric separators was reported by Abtahi et al. [33] for the placebo group 48 hrs after application of OF, with a mean value of 7.45. The highest intensity reported by Nóbrega et al. [27] was 6.45. In canine retraction, the pain in the experimental and placebo groups was similar in all periods [9, 38]. According to the literature, the highest levels of pain were found after the installation of light archwires, with a value of 8.55 for the placebo group 24 hrs after the application of OF, measured using the Numeric Rating Scale [35]. Bayani et al. [34] state that patients in the placebo group reported chewing pain of up to 7 on the VAS, while patients in the experimental group (treated with laser) reported an average value of 3.2. The authors also report that pain lasted for longer in the untreated group [22, 24, 27] and took longer to disappear, persisting in 10% of subjects in the laser group and in 70–80% of subjects in the control/placebo group [22]. In Nóbrega et al. [27], the patients in both the control and irradiated groups stated that pain in occlusion was more severe than spontaneous pain, hindering chewing. These authors also observed that an expressive percentage of patients in the placebo group, up to 60%, still presented occlusion pain on day 5 after activation, while only 23.3% of the patients in the LLLT group still presented occlusion pain [27].

In the present meta-analysis, 24 and 72 hrs after the installation of elastomeric separators the LLLT group presented lower mean values for spontaneous and chewing pain than the placebo group. In patients fitted with light archwires, laser was effective in reducing spontaneous pain at 24 and 72 hrs after OT. Patients treated with laser reported less pain intensity (spontaneous and chewing) 24 hrs after OT, when the peak pain usually occurs [23, 26, 29, 3234, 37]. Laser also proved to have a prolonged analgesic effect, reducing pain even 72 hrs after the installation of elastomeric separators. It should be noted that methodological issues limited the overall quality of evidence. The studies presented risk of bias associated with selection bias, performance bias, and selective reporting bias, compromising the internal validity of the investigation, since all the studies presented low quality of evidence.

Bjordal et al. [10] observed that optimal effects of LLLT on acute pain can be achieved by using a dose of 7.5 J/cm2 in the first 72 hours after the injury to reduce inflammation; the dose must be reduced in subsequent days, typically to 2 J/cm2, to promote tissue repair. Lizarelli [47] indicated a dose of ≥5 and <20 J/cm2 for severe pain so as not to inhibit cell activity. Other authors state that higher doses, for example, 35 J/cm2 [47], are needed to reduce orthodontic pain and that doses of 5 J/cm2 are not effective [9]. We observed that studies with similar protocols reported conflicting results. Farias et al. [24], Furquim et al. [29], and Abtahi et al. [33] used the same total energy (6 J/tooth); moreover, Farias et al. [24] and Furquim et al. [29] used similar wavelengths; however, only Farias et al. [24] reported a reduction in pain. We also observed that different irradiation parameters promoted analgesia in orthodontic patients. Qamruddin et al. [23] and Artés-Ribas et al. [26] used the same total energy (12 J/tooth) but different wavelengths, 940 nm and 830 nm, respectively; both reported successful treatment. Artés-Ribas et al. [26] and Bicakci et al. [31], who were also successful in reducing orthodontic pain, used similar wavelengths and doses (J/cm2/tooth); however, they used different total energies, of 12 J and 1 J, respectively. When we analysed the parameters used in the studies in which no reduction in orthodontic pain was found, we observed that they used a wavelength outside the range 808–830 nm, and/or the total energy administered was very high. Based on the above, we agree with studies which state that the success of LLLT is related to the energy applied [9, 47, 58]. We also think that energy density (J/cm2/tooth) cannot be the only parameter determining successful treatment. Moreover, laser therapy appears to present better results when it is associated with the use of a wavelength of 800–830 nm and total energy ≤12 J/tooth/treatment session; energy density is highly variable, with pain reduction being achieved with applications ranging from 5 J/cm2 to 160 J/cm2 per tooth. The laser irradiation parameters must be selected according to the clinical situation, based on the current phase of the lesion and considering the optical characteristics of the tissue to be irradiated and the laser irradiation methodology (point or sweep, contact or noncontact) [47]. The area to be irradiated is determined by the type of device used to apply the laser; the dose applied to the tissue can be changed by changing the spot size. Thus, the energy density applied to the tissue can be increased by reducing the spot size, which will also result in greater irradiance and penetration of the laser into the biological tissue [47]. In this meta-analysis, when more than one protocol was reported by any author, the protocol which used the lowest energy dose was selected.

More than 50% of the studies analysed present an incomplete or unclear irradiation protocol, failing to include important information such as spot size, energy density per spot and per tooth, application time/spot, and total energy per spot and per tooth. Although the studies often presented sufficient information for missing parameters to be calculated, the absence of these data complicates routine use of the protocols, often preventing reproduction in clinical practice. Future studies should seek to improve the methodological criteria used in order to allow comparison between all the parameters used by each author. New double-blind, randomized clinical trials reporting the correct allocation of patients, complete information on the protocol used, the application method, and the use of one group of patients for the control and another group to form the LLLT group, with well-defined inclusion/exclusion criteria, would reduce the risk of bias which arises during research activities and analysis of the results.

In the present investigation, 13 studies (65%) reported pain reduction in orthodontic patients with the use of LLLT. Note that in seven studies (35%) no differences were found in pain intensity between patients in the LLLT group and those who did not receive LLLT; these were three studies of canine retraction [9, 39, 40] and four in which elastomeric separators were fitted [25, 29, 30, 33]. AlSayed Hasan et al. [30] compared two different doses of LLLT, one of 2.25 J/cm2/tooth and one of 9 J/cm2/tooth; neither of the protocols proved effective in reducing pain after the fitting of elastomeric separators. Lim et al. [25] compared three different protocols with application times of 15 s, 30 s, and 60 s per tooth; all three protocols failed to reduce orthodontic pain caused by the fitting of elastomeric separators. Hawkins and Abrahamse [59] state that dosage (or fluence) can alter cell processes. The application of a low or very low dose may produce no effect, while very high doses may produce negative or inhibiting effects. This may explain why studies were found with contradictory results [60]. The origin of contradictory scientific evidence may be related to the multiple methods used for laser irradiation, as there is no protocol indicating which irradiation doses are most effective. There is a need for new studies presenting a low risk of bias to discover which laser irradiation protocol offers the greatest analgesic power in orthodontic patients.

We agree with Marini et al. [22] when they suggest the possibility of using the LLLT protocol in daily orthodontic practice. New studies are needed to develop a complete protocol for easy application and execution in clinical practice, in order to convert safe laser irradiation with effective dosing into a routine treatment for orthodontic pain.

4.2. Study Limitations

We identified some limitations in our review process. First, there is the possibility that we failed to identify all studies because we only considered articles published in English. However, we believe that this was minimized due to the large number of databases used, the additional search of references by hand, and the double independent review process used. Second, some studies could not be included in any of the meta-analyses because of the lack of the specific estimator needed; however, their individual data were consistent with our findings. Third, the internal validity of the summary provided by a meta-analysis depends on the quality of the primary studies; the risk of bias in the most of studies included was high. Finally, because we did not have more than ten studies to pool in any meta-analysis, funnel plots to explore possible publication biases were not constructed.

5. Conclusions

Randomized clinical trials to assess the effect of laser (near infrared) on orthodontic pain present great heterogeneity of irradiation parameters; conflicting results were found even in studies using similar parameters. The heterogeneity of LLLT protocols for the treatment of orthodontic pain hinders comparison between studies; moreover, it has not yet been possible to standardise the best protocol for routine use in clinical practice. New studies are needed to establish an effective LLLT protocol to obtain greater analgesia in patients undergoing orthodontic forces, which can be used routinely in clinical practice. The majority of the RCT in the present study reported results which favoured laser, showing that LLLT is beneficial for the patient; however, there were an expressive number of studies reporting that laser was not effective. LLLT has been shown to be effective in reducing spontaneous and chewing pain after the installation of elastomeric separators and light archwires. Furthermore, the analgesic effect of laser extends for 72 hrs after the installation of elastomeric separators, reducing spontaneous and chewing pain; however, the poor quality of the evidence requires these results to be treated with caution.

Conflicts of Interest

The authors declare they have no conflicts of interest.

References

  • 1.Limpanichkul W., Godfey K., Srisuk N., Rattanayatikul C. Effects of low-level laser therapy on the rate of orthodontic tooth movement. Orthodontics & Craniofacial Research. 2006;9(1):38–43. doi: 10.1111/j.1601-6343.2006.00338.x. [DOI] [PubMed] [Google Scholar]
  • 2.Azuma M. Study on histologic changes of periodontal membrane incident to experimental tooth movement. The Bulletin of Tokyo Medical and Dental University. 1970;17:149–178. [PubMed] [Google Scholar]
  • 3.Sandstedt C. Einige Beitrage zur Theorie der Zahnregulierung. Nordisk Tandilakare Tidskift. 1904;5:236–256. [Google Scholar]
  • 4.Macapanpan L. C. Early tissue changes following tooth movementin rats. Angle Orthodontic. 1954;24:79–95. [Google Scholar]
  • 5.Garlet T. P., Coelho U., Silva J. S., Garlet G. P. Cytokine expression pattern in compression and tension sides of the periodontal ligament during orthodontic tooth movement in humans. European Journal of Oral Sciences. 2007;115(5):355–362. doi: 10.1111/j.1600-0722.2007.00469.x. [DOI] [PubMed] [Google Scholar]
  • 6.Katagiri T., Takahashi N. Regulatory mechanisms of osteoblast and osteoclast differentiation. Oral Diseases. 2002;8(3):147–159. doi: 10.1034/j.1601-0825.2002.01829.x. [DOI] [PubMed] [Google Scholar]
  • 7.Youssef M., Ashkar S., Hamade E., Gutknecht N., Lampert F., Mir M. The effect of low-level laser therapy during orthodontic movement: A preliminary study. Lasers in Medical Science. 2008;23(1):27–33. doi: 10.1007/s10103-007-0449-7. [DOI] [PubMed] [Google Scholar]
  • 8.Kavaliauskiene A., Smailiene D., Buskiene I., Keriene D. Pain and discomfort perception among patients undergoing orthodontic treatment: results from one month follow-up study. Stomatologija. 2012;14(4):118–125. [PubMed] [Google Scholar]
  • 9.Angelieri F., Sousa M. V. D. S., Kanashiro L. K., Siqueira D. F., Maltagliati L. Á. Effects of low intensity laser on pain sensitivity during orthodontic movement. Dental Press Journal of Orthodontics. 2011;16(4):95–102. doi: 10.1590/S2176-94512011000400016. [DOI] [Google Scholar]
  • 10.Bjordal J. M., Johnson M. I., Iversen V., Aimbire F., Lopes-Martins R. A. B. Photoradiation in acute pain: A systematic review of possible mechanisms of action and clinical effects in randomized placebo-controlled trials. Photomedicine and Laser Surgery. 2006;24(2):158–168. doi: 10.1089/pho.2006.24.158. [DOI] [PubMed] [Google Scholar]
  • 11.Vandevska-Radunovic V. Neural modulation of inflammatory reactions in dental tissues incident to orthodontic tooth movement. A review of the literature. European Journal of Orthodontics. 1999;21(3):231–247. doi: 10.1093/ejo/21.3.231. [DOI] [PubMed] [Google Scholar]
  • 12.Polat O., Karaman A. I. Pain control during fixed orthodontic appliance therapy. The Angle Orthodontist. 2005;75(2):210–215. doi: 10.1043/0003-3219(2005)075<0210:PCDFOA>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
  • 13.Giannopoulou C., Dudic A., Kiliaridis S. Pain Discomfort and Crevicular Fluid Changes Induced by Orthodontic Elastic Separators in Children. Journal of Pain. 2006;7(5):367–376. doi: 10.1016/j.jpain.2005.12.008. [DOI] [PubMed] [Google Scholar]
  • 14.Arias O. R., Marquez-Orozco M. C. Aspirin, acetaminophen, and ibuprofen: Their effects on orthodontic tooth movement. American Journal of Orthodontics and Dentofacial Orthopedics. 2006;130(3):364–370. doi: 10.1016/j.ajodo.2004.12.027. [DOI] [PubMed] [Google Scholar]
  • 15.Vachiramon A., Wang W. C. Acupuncture and acupressure techniques for reducing orthodontic post-adjustment pain. The Journal of Contempary Dental Practice. 2005;6(1):163–167. [PubMed] [Google Scholar]
  • 16.Neves L. S., Silva C. M. S., Henriques J. F. C., Cançado R. H., Henriques R. P., Janson G. A utilização do laser em Ortodontia. evista Dental Press de Ortodontia e Ortopedia Facial. 2005;10:149–156. [Google Scholar]
  • 17.Walker J. B., Buring S. M. NSAID impairment of orthodontic tooth movement. The Annals Pharmacotherapy. 35(1):113–115. doi: 10.1345/aph.10185. [DOI] [PubMed] [Google Scholar]
  • 18.Holberg Peters F., Zaror Sánchez C., Fabres Suarez R., Sandoval P., Vidal. Use of laser therapy in pain control in orthodontics. Revista Clínica de Periodoncia, Implantología y Rehabilitación Oral. 2011;4(3):114–116. [Google Scholar]
  • 19. J. P. T. Higgins and S. Green, Eds., “Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0”, The Cochrane Collaboration, March 2011, http://handbook.cochrane.org.
  • 20.Langendam M. W., Aki E. A., Dahm P., Glasziou P., Guyatt G., Schunemann H. J. Assessing and presenting summaries of evidence in Cochrane Reviews. Systematic Reviews. 2013;2:p. 81. doi: 10.1186/2046-4053-2-81. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Liberati A., Altman D. G., Tetzlaff J., et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. The British Medical Journal. 2009;339 doi: 10.1136/bmj.b2700.b2700 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Marini I., Bartolucci M. L., Bortolotti F., Innocenti G., Gatto M. R., Alessandri Bonetti G. The effect of diode superpulsed low-level laser therapy on experimental orthodontic pain caused by elastomeric separators: a randomized controlled clinical trial. Lasers in Medical Science. 2015;30(1):35–41. doi: 10.1007/s10103-013-1345-y. [DOI] [PubMed] [Google Scholar]
  • 23.Qamruddin I., Alam M. K., Fida M., Khan A. G. Effect of a single dose of low-level laser therapy on spontaneous and chewing pain caused by elastomeric separators. American Journal of Orthodontics and Dentofacial Orthopedics. 2016;149(1):62–66. doi: 10.1016/j.ajodo.2015.06.024. [DOI] [PubMed] [Google Scholar]
  • 24.Farias R. D., Closs L. Q., Miguens S. A. Q. Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: A randomized split-mouth clinical trial. Angle Orthodontist. 2016;86(2):193–198. doi: 10.2319/122214-933.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Lim H.-M., Lew K. K. K., Tay D. K. L. A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic postadjustment pain. American Journal of Orthodontics and Dentofacial Orthopedics. 1995;108(6):614–622. doi: 10.1016/S0889-5406(95)70007-2. [DOI] [PubMed] [Google Scholar]
  • 26.Artés-Ribas M., Arnabat-Dominguez J., Puigdollers A. Analgesic effect of a low-level laser therapy (830 nm) in early orthodontic treatment. Lasers in Medical Science. 2013;28(1):335–341. doi: 10.1007/s10103-012-1135-y. [DOI] [PubMed] [Google Scholar]
  • 27.Nóbrega C., Da Silva E. M. K., De Macedo C. R. Low-level laser therapy for treatment of pain associated with orthodontic elastomeric separator placement: A placebo-controlled randomized double-blind clinical trial. Photomedicine and Laser Surgery. 2013;31(1):10–16. doi: 10.1089/pho.2012.3338. [DOI] [PubMed] [Google Scholar]
  • 28.Almallah M. M. E., Almahd W. H., Hajeer M. Y. Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: A randomized split-mouth clinical trial. Journal of Clinical and Diagnostic Research. 2016;10(11):ZC23–ZC28. doi: 10.7860/JCDR/2016/22813.8804. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Furquim R. D., Pascotto R. C., Neto J. R., Cardoso J. R., Ramos A. L. Low-level laser therapy effects on pain perception related to the use of orthodontic elastomeric separators. Dental Press Journal of Orthodontics. 2015;20(3):37–42. doi: 10.1590/2176-9451.20.3.037-042.oar. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.AlSayed Hasan M. M. A., Sultan K., Hamadah O. Evaluating low-level laser therapy effect on reducing orthodontic pain using two laser energy values: a split-mouth randomized placebo-controlled trial. European Journal of Orthodontics. 2017 doi: 10.1093/ejo/cjx013. [DOI] [PubMed] [Google Scholar]
  • 31.Bicakci A. A., Kocoglu-Altan B., Toker H., Mutaf I., Sumer Z. Efficiency of low-level laser therapy in reducing pain induced by orthodontic forces. Photomedicine and Laser Surgery. 2012;30(8):460–465. doi: 10.1089/pho.2012.3245. [DOI] [PubMed] [Google Scholar]
  • 32.Eslamian L., Borzabadi-Farahani A., Hassanzadeh-Azhiri A., Badiee M. R., Fekrazad R. The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers in Medical Science. 2014;29(2):559–564. doi: 10.1007/s10103-012-1258-1. [DOI] [PubMed] [Google Scholar]
  • 33.Abtahi S. M., Mousavi S. A., Shafaee H., Tanbakuchi B. Effect of low-level laser therapy on dental pain induced by separator force in orthodontic treatment. Dental Research Journal. 2013;10(5):647–651. [PMC free article] [PubMed] [Google Scholar]
  • 34.Bayani S., Rostami S., Ahrari F., Saeedipouya I. A randomized clinical trial comparing the efficacy of bite wafer and low level laser therapy in reducing pain following initial arch wire placement. Laser Therapy. 2016;25(2):121–129. doi: 10.5978/islsm.16-OR-10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Tortamano A., Lenzi D. C., Haddad A. C. S. S., Bottino M. C., Dominguez G. C., Vigorito J. W. Low-level laser therapy for pain caused by placement of the first orthodontic archwire: A randomized clinical trial. American Journal of Orthodontics and Dentofacial Orthopedics. 2009;136(5):662–667. doi: 10.1016/j.ajodo.2008.06.028. [DOI] [PubMed] [Google Scholar]
  • 36.Deshpande P., Patil K., Mahima V., Shivalinga B. M., Suchetha M., Ranjan A. Low-level laser therapy for alleviation of pain from fixed orthodontic appliance therapy: a randomized controlled trial. Journal of Advanced Clinical & Research Insights. 2016;3:43–46. [Google Scholar]
  • 37.Domínguez A., Velásquez S. A. Effect of low-level laser therapy on pain following activation of orthodontic final archwires: A randomized controlled clinical trial. Photomedicine and Laser Surgery. 2013;31(1):36–40. doi: 10.1089/pho.2012.3360. [DOI] [PubMed] [Google Scholar]
  • 38.Doshi-Mehta G., Bhad-Patil W. A. Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: A clinical investigation. American Journal of Orthodontics and Dentofacial Orthopedics. 2012;141(3):289–297. doi: 10.1016/j.ajodo.2011.09.009. [DOI] [PubMed] [Google Scholar]
  • 39.Dalaie K., Hamedi R., Kharazifard M. J., Mahdian M., Bayat M. Effect of low-level laser therapy on orthodontic tooth movement: a clinical investigation. Journal of Dentistry of Tehran University of Medical Science. 2015;12(4):249–256. [PMC free article] [PubMed] [Google Scholar]
  • 40.Heravi F., Moradi A., Ahrari F. he Effect of Low Level Laser Therapy on the Rate of Tooth Movement and Pain Perception during Canine Retraction. Oral Health and Dental Management. 2014;3(2):183–188. [PubMed] [Google Scholar]
  • 41.Ngan P., Kess B., Wilson S. Perception of discomfort by patients undergoing orthodontic treatment. American Journal of Orthodontics and Dentofacial Orthopedics. 1989;96(1):47–53. doi: 10.1016/0889-5406(89)90228-X. [DOI] [PubMed] [Google Scholar]
  • 42.Monea A., Mo M., Pop D., Berseşcu G. The effect of low level laser therapy on orthodontic tooth movement. Optoelectronics and Advanced Materials. 2015;9(1-2):286–289. [Google Scholar]
  • 43.Domínguez-Camacho A., Velasquez-Cujar S. A. Acceleration effect of orthodontic movement by application of low- intensity laser. Journal of Oral Laser Applications. 2010;10:99–105. [Google Scholar]
  • 44.Chow R. T., David M. A., Armati P. J. 830 nm laser irradiation induces varicosity formation, reduces mitochondrial membrane potential and blocks fast axonal flow in small and medium diameter rat dorsal root ganglion neurons: implications for the analgesic effects of 830 nm laser. Journal of the Peripheral Nervous System. 2007;12(1):28–39. doi: 10.1111/j.1529-8027.2007.00114.x. [DOI] [PubMed] [Google Scholar]
  • 45.Montesinos M. Experimental effects of low power laser in encephalon and endorphin synthesis. Journal of European Medical Laser Association. 1988;1:2–7. [Google Scholar]
  • 46.Shimizu N., Yamaguchi M., Goseki T., et al. Inhibition of prostaglandin E2 and interleukin 1-beta production by low-power laser irradiation in stretched human periodontal ligament cells. Journal of Dental Research. 1995;74(7):1382–1388. doi: 10.1177/00220345950740071001. [DOI] [PubMed] [Google Scholar]
  • 47.Lizarelli R. F. Z. Protocolos Clínicos Odontológicos: Uso Do Laser De Baixa Intensidade. São Carlos, Brazil: Gorham Design; 2007. [Google Scholar]
  • 48.Harris D. M. Biomolecular mechanisms of laser biostimulation. Journal of Clinical Laser Medicine & Surgery. 1991;9(4):277–280. [Google Scholar]
  • 49.Harazaki M., Isshiki Y. Soft laser irradiation induced pain reduction in orthodontic treatment. The Bulletin of Tokyo Dental College. 1998;39(2):95–101. [PubMed] [Google Scholar]
  • 50.Wakabayashi H., Hamba M., Matsumoto K., Tachibana H. Effect of irradiation by semiconductor laser on responses evoked in trigeminal caudal neurons by tooth pulp stimulation. Lases in Surgery and Medicine. 1993;13:605–610. doi: 10.1002/lsm.1900130603. [DOI] [PubMed] [Google Scholar]
  • 51.Yamaguchi M., Yoshii M., Kasai K. Relationship between substance P and interleukin-1β in gingival crevicular fluid during orthodontic tooth movement in adults. European Journal of Orthodontics. 2006;28(3):241–246. doi: 10.1093/ejo/cji100. [DOI] [PubMed] [Google Scholar]
  • 52.Hashmi J. T., Huang Y.-Y., Sharma S. K., et al. Effect of pulsing in low-level light therapy. Lasers in Surgery and Medicine. 2010;42(6):450–466. doi: 10.1002/lsm.20950. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Kymplová J., Navrátil L., Knízek J. Contribution of phototherapy to the treatment of episiotomies. Journal of Clinical Laser Medicine and Surgery. 2003;21(1):35–39. doi: 10.1089/10445470360516725. [DOI] [PubMed] [Google Scholar]
  • 54.Sushko B. S., u I., Lymanskyi P., Huliar S. O. Action of the red and infrared electromagnetic waves of light-emitting diodes on the behavioral manifestation of somatic pain. Fiziologicheskiĭ Zhurnal. 2007;53(3):51–60. [PubMed] [Google Scholar]
  • 55.Antczak‐Bouckoms A. A., Tulloch J. F. C., Berkey C. S. Split‐mouth and cross‐over designs in dental research. Journal of Clinical Periodontology. 1990;17(7):446–453. doi: 10.1111/j.1600-051X.1990.tb02343.x. [DOI] [PubMed] [Google Scholar]
  • 56.Hujoel P. P., DeRouen T. A. Validity issues in split‐mouth trials. Journal of Clinical Periodontology. 1992;19(9):625–627. doi: 10.1111/j.1600-051X.1992.tb01709.x. [DOI] [PubMed] [Google Scholar]
  • 57.Pandis N., Walsh T., Polychronopoulou A., Katsaros C., Eliades T. Split-mouth designs in orthodontics: An overview with applications to orthodontic clinical trials. European Journal of Orthodontics. 2013;35(6):783–789. doi: 10.1093/ejo/cjs108. [DOI] [PubMed] [Google Scholar]
  • 58.Karu T. I. Effects of visible radiation on cultured cells. Photochemistry and Photobiology. 1990;52(6):1089–1098. doi: 10.1111/j.1751-1097.1990.tb08450.x. [DOI] [PubMed] [Google Scholar]
  • 59.Hawkins D. H., Abrahamse H. The role of laser fluence in cell viability, proliferation, and membrane integrity of wounded human skin fibroblasts following Helium-Neon laser irradiation. Lasers in Surgery and Medicine. 2006;38(1):74–83. doi: 10.1002/lsm.20271. [DOI] [PubMed] [Google Scholar]
  • 60.Simunovic Z. Low level laser therapy with trigger points technique:a clinical study on 243 patients. Journal of Clinical Laser Medicine & Surgery. 1996;14(4):163–167. doi: 10.1089/clm.1996.14.163. [DOI] [PubMed] [Google Scholar]

Articles from Pain Research & Management are provided here courtesy of Wiley

RESOURCES