Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2017 Oct 11;7:12949. doi: 10.1038/s41598-017-13281-8

Highly sensitive, self-powered and wearable electronic skin based on pressure-sensitive nanofiber woven fabric sensor

Yuman Zhou 1, Jianxin He 2,3,, Hongbo Wang 1,, Kun Qi 1, Nan Nan 2,3, Xiaolu You 2,3, Weili Shao 2,3, Lidan Wang 2,3, Bin Ding 2,4, Shizhong Cui 2,3
PMCID: PMC5636882  PMID: 29021591

Abstract

The wearable electronic skin with high sensitivity and self-power has shown increasing prospects for applications such as human health monitoring, robotic skin, and intelligent electronic products. In this work, we introduced and demonstrated a design of highly sensitive, self-powered, and wearable electronic skin based on a pressure-sensitive nanofiber woven fabric sensor fabricated by weaving PVDF electrospun yarns of nanofibers coated with PEDOT. Particularly, the nanofiber woven fabric sensor with multi-leveled hierarchical structure, which significantly induced the change in contact area under ultra-low load, showed combined superiority of high sensitivity (18.376 kPa−1, at ~100 Pa), wide pressure range (0.002–10 kPa), fast response time (15 ms) and better durability (7500 cycles). More importantly, an open-circuit voltage signal of the PPNWF pressure sensor was obtained through applying periodic pressure of 10 kPa, and the output open-circuit voltage exhibited a distinct switching behavior to the applied pressure, indicating the wearable nanofiber woven fabric sensor could be self-powered under an applied pressure. Furthermore, we demonstrated the potential application of this wearable nanofiber woven fabric sensor in electronic skin for health monitoring, human motion detection, and muscle tremor detection.

Introduction

Human skin, a natural multi-functional sensor, can transmit mechanical stimulation, temperature, humidity, and other information received from the surrounding objects to the central nervous system, and then the received information is recognized by the human brain during the neural transmission system through the inter-transformation between physical signals and chemical signals1,2. Pressure-sensitive electronic skins, inspired by human skin, have important applications in health monitoring, robotic skin, surgery, highly sensitive sensing equipment, and intelligent electronic products because it can mimic real human skin to detect pressure, deformation, movement, and other static or dynamic external stimuli with high accuracy37. To achieve accurate real-time health monitoring by detecting parameters such as pulse, heartbeat, and muscle vibration, electronic skin that can be applied in daily lives needs to be woven into a fabric to meet the clothing requirements of people, in addition to meeting the requirements of high sensitivity, low power and fabrication cost, and large-area implementation811.

To date, pressure-sensitive electronic skin based on flexible substrates has made great progress1216. Piezoresistive sensors detect various tactile stimuli though the change of electrical resistance, and the change of contact resistance between conducting materials is one of the important approaches to realize sensors with high pressure sensitivity under mechanical deformation17. Currently, flexible electronic skins are usually fabricated using template-synthesis to construct multifarious structures on flexible substrates, such as interlocked micro-convex18,19, pyramid20,21, and fingerprint structures22, for increasing the sensitivity of the pressure sensor.

Jiang et al. reported a flexible nanofiber sensor with high sensitivity (15.6 kPa−1) and low detection limit (1.2 Pa) based on a modular assembly of a polyvinylidene fluoride-trifluoroethylene copolymer P(VDF-TrFE) nanofiber sensor encapsulated by reduced graphene oxide (rGO)23. Ko et al. prepared a piezoresistive sensor with a tunneling effect based on carbon nanotube-based composite elastomers having interlocked array structures, and they achieved a sensitivity of 15.1 kPa−1 at low loads24. Although these flexible pressure-sensitive sensors have high sensitivity, most previously reported sensors still cannot be woven for wearability owing to the limitation of their membrane structure.

Lu et al. proposed a simple self-assembly strategy for constructing a super-sensitive pressure sensor by coating PU yarns with ultra-thin elastic conductive layers consisting of carbon black and natural rubber, which could be woven into a fabric to monitor minute human movements25. Yu et al. fabricated an electronic fabric based on intertwined sensor electrodes with piezoresistive rubber as the shell sensing element and elastic thread coated with silver nanowires as the stretchable and highly conductive core electrode26. Because of the unique coaxial structure and fibrous sensor architecture, sensor had the ability to accurately capture applied loads. Despite high sensitivity and the ability to be woven, the complex yarn structures and external power supply of this wearable electronic skin remain problems to be overcome for its actual application.

Therefore, electronic skin should be self-powered to realize continuous energy supply and portability in daily use2730. Dahiya et al. described an energy-autonomous flexible and transparent electronic skin with a novel structure, consisting of a transparent tactile sensitive layer based on single-layer graphene and a photovoltaic cell underneath as a building block for energy-autonomous31. This structure makes the sensor highly sensitive over a wide range of pressures (0.11–80 kPa) and had a promising alternative to replace the battery with a solar cell in the back plane of the touch sensors. Wang et al. introduced an electric eel-skin-inspired mechanically durable and resilient triboelectric nanogenerator by embedding AgNWs in the silicone rubber, and typical output performances of the device including open-circuit voltage, transferred charge density, and short-circuit current density were obtained by applying a 10 N contact force with different frequency32. These results are beneficial for a wide range of deformable power source, deformable electronics, and fully autonomous electronic skin and interactive systems.

Considering the above-mentioned problems, in the present study, we developed a design of highly sensitive, self-powered, and wearable electronic skin based on a pressure-sensitive nanofiber woven fabric sensor fabricated by weaving polyvinylidene fluoride (PVDF) electrospun yarns of nanofibers coated with poly(3,4-ethylenedioxythiophene) (PEDOT). The novel design of multi-leveled hierarchical structure for our prepared nanofiber woven fabric sensor significantly induced the change in contact area under ultra-low load, which resulted in a great change in resistance and accordingly endowed the sensor with a high pressure sensitivity. In addition, the wearable nanofiber woven fabric sensor could be self-powered with outstanding sensitivity. This wearable nanofiber woven fabric sensor has perfect application in electronic skin for health monitoring systems that can be used in daily life.

Results and Discussion

Figure 1a illustrates the fabrication of the PEDOT@PVDF nanofiber woven fabric. PVDF nanofiber yarns were continuously prepared using the method we previously reported33, and they were bundled and twisted by parallel nanofibers with diameter ranging from 100 nm to 200 nm (Figure S1). The obtained PVDF nanofiber yarns were treated with KOH/KMnO4 mixed solution to increase the number of oxygen-containing groups on the fiber surface. The oxidation treatment of the nanofiber yarns increased the surface roughness of the PVDF nanofiber and yielded a remarkable improvement in hydrophilicity of the yarn with a decrease of contact angle from 127° to 46° (Figure S2). The treated PVDF nanofiber yarns were dipped into a solution of FeCl3 in ethanol, and the adsorption of FeCl3 as a catalyst for the polymerization of EDOT on the fiber surface transformed the color of the yarn from white to light yellow. The resulting PVDF nanofiber yarns were immersed in a solution of EDOT in chloroform, and EDOT was polymerized in situ on the surface of the fibers in the yarn, with FeCl3 acting as a catalyst, to form PEDOT@PVDF nanofiber yarns composed of PEDOT-coated PVDF nanofibers. After the in-situ polymerization of EDOT on the fiber surface, the color of the PEDOT@PVDF nanofiber yarn changed to blue-green. It should also be noted that the stress intensity of PEDOT@PVDF nanofibers yarns is close to that of commercial viscose filament, and were able to meet the requirement of weaving (Figure S3). The obtained PEDOT@PVDF nanofiber yarns could be easily woven into a double-layer fabric, following which a wearable PEDOT@PVDF nanofiber woven fabric (PPNWF) pressure sensor with a sandwich structure was assembled by gluing PDMS films with copper wires on both the upper and lower sides of the double-layer fabric (Figure S4).

Figure 1.

Figure 1

(a) Schematic illustrations for preparation of PEDOT@PVDF nanofiber woven fabric; (b) optical image of PEDOT@PVDF nanofiber fabric; SEM images of PEDOT@FVDF (c) nanofiber fabric, (d) nanofiber yarn, (e) oriented nanofibers, and (f) single nanofiber.

Figure 1b shows an optical image of the PPNWF. A perfect weaving structure was observed in typical scanning electron microscopy (SEM) images of the PEDOT@PVDF nanofiber fabric, which the warp and weft yarns are crisscross assembled and interlaced with each other in an over-and-under fashion (Fig. 1c). Subsequently, a multi-joint channel system is formed in which the interlacing of warp and weft yarns formed a regular protuberance acting as the mechanical sensing unit. The double-layer fabric structure enhanced the interlocking possibility of regular sites because external pressure induces stress to focus on the small sites and deforms the sites. Figure 1d and e shows typical SEM images of the PEDOT@PVDF nanofiber yarn, in which the fibers are almost arranged in parallel in the direction of twist with its diameter increasing from the range of 100–200 nm to 500–600 nm after PEDOT coating (Fig. 1f). The enlarged field-emission SEM (FESEM) image of a single PEDOT@PVDF nanofiber in Fig. 1g revealed an accidented topography on the fiber surface, and the fiber was evenly coated by in-situ polymerized PEDOT particles with size in the range of 30–50 nm. X-ray photoelectron spectroscopy (XPS) spectra of PEDOT@PVDF nanofiber yarn demonstrated the disappearance of the characteristic F-signal peaks of PVDF and the appearance of O- and S-signal peaks (Fig. 2a). Moreover, the XPS S2p de-convolution spectra of PEDOT@PVDF nanofiber yarn showed peaks located at 163.4 eV and 164.8 eV, corresponding to the binding energy of S2p3/2 and S2p1/2 of PEDOT, respectively (Fig. 2b), which is consistent with previous reports3436. The transmission electron microscopy (TEM) image shown in Fig. 2c also confirmed the core-shell structure of the nanofiber in the PEDOT@PVDF nanofiber yarn with a continuously coated PEDOT shell layer, and the mapping image of S element in PEDOT revealed S element was distributed uniformly on the fiber surface (Fig. 2d). The above results demonstrate that the PVDF nanofibers were uniformly coated with PEDOT in yarns, which could be used as continuous self-assembled conductive pathways in the PPNWF pressure sensor.

Figure 2.

Figure 2

(a) TEM image of PEDOT@PVDF nanofiber; (b) mapping image of the S element in PEDOT; XPS results of (c) wide-scan spectrum of PVDF and PEDOT@PVDF nanofiber yarn and (d) S2p spectrum of PEDOT in PEDOT@PVDF nanofiber yarn.

Hierarchical geometrical features inspired by structures found in nature have displayed many advantages, one of which is the maximized contact area37. Cho et al. applied three-level hierarchically structured Gr/PDMS arrays with protuberances having a diameter of 59 μm and microdomes having a diameter of 3.2 μm to pressure-sensitive electronic skin and demonstrated a high sensitivity of 8.5 kPa−1 at low loads and a wide pressure range (~12 kPa)38. Similarly, the interlaced joint of warp and weft yarns as a protuberance at a dimension of 200–300 μm was composed of submicro-scale fibers 500–600 nm in size coated continuously with nanoscale PEDOT nanoparticles 30–50 nm in size. The multi-level dome arrays from the microscale to nanoscale in the PPNWF pressure sensor can be modeled as a hierarchical structure, which can afford more contact joints and a large variation in contact area for pressure sensing, thereby contributing to the ability to capture subtle stresses and to the increase of sensitivity.

The XRD pattern in Figure S4c shows a transformation in the crystalline texture of PVDF powder from the α-phase to β-phase after electrospinning, and only the β-phase of PVDF showed piezoelectricity39,40, which was well maintained after the in-situ polymerization of EDOT coating.

A self-made pressure-sensitive test system was assembled to study the pressure sensitivity of the PPNWF pressure sensor (Figure S5). The current-voltage (I-V) curve of the PPNWF pressure sensor showed that the current of our fabricated sensor, which was used as a resistive element in this testing circuit of volt-ampere characteristic, varied linearly with the voltage (Fig. 3a), indicating the sensor had good ohmic behavior with a stable response to pressure and the current increased significantly with pressure increasing from 0 Pa to 10 kPa. During the testing process of current-voltage characteristic, the working voltage is changed from 0 V to 1 V. Theoretically, the current of the sensor should be 0 A at the origin when the initial working voltage is 0 V, regardless of how much the resistance of the PPNWF pressure sensor changed under the pressure. Noticeably, an initial current existed at the origin when different pressures were applied to the sensor, and the initial current of the sensor increased from 0 mA to 4.328 × 10–5 mA when the pressure loading was increased from 0 Pa to 10 kPa. (Fig. 3b). This phenomenon indicated that, there had another voltage in the circuit in addition to the testing voltage under increasing pressure, which led to the existence of the current. In other word, our sensor might be self-powered. In order to eliminate the interference of external factors, we used a piezoelectric performance testing system to test the self-powering effect of the PPNWF pressure sensor. We obtained an open-circuit voltage signal of the PPNWF pressure sensor under an applied periodic pressure of 10 kPa through the piezoelectric performance testing system, and the output voltage exhibited a distinct switching behavior to the applied pressure (Fig. 3c). The reason of the self-powering effect for the PPNWF pressure sensor could be explained by the piezoelectricity of PVDF β-phase. Furthermore, the voltage generated in the PPNWF pressure sensor increased with the increase of applied pressure (Fig. 3d).

Figure 3.

Figure 3

(a) I-V curves of PPNWF pressure sensor and (b) initial current under different pressures; (c) open-circuit voltage signal of PPNWF pressure sensor under an applied periodic pressure of 10 kPa; (d) voltage signal of PPNWF pressure sensor under different pressures.

The pressure sensitivity of the PPNWF pressure sensor was further investigated by monitoring the relative current change under different pressure loads (ΔI/I0) at a working voltage of 1 V. The pressure sensitivity S of the pressure sensor is defined as the slope of the curve shown in Fig. 4a. The pressure sensitivity S is calculated as follows:

S=(ΔI/I0)/ΔP 1

where ΔI is the pressure-induced change in current (mA), I0 is the initial current of the sensor without pressure loading (mA), and ΔP is the change in applied pressure (kPa).

Figure 4.

Figure 4

(a) Relative change in current versus applied pressure; (b) Static current response under varying pressure; (c) Dynamic instantaneous current response to varying pressure; (d) Schematic diagram of the main structural change in the PPNWF pressure sensor during the compression process; (e) Response to applied pressure with various frequencies; (f) a typical signal of current change at 25 Hz in (e); (g) Durability recorded by repeated loading-unloading cycles at a frequency of 25 Hz and a pressure of 10 kPa.

As shown in Fig. 4a, the relative change in current of the prepared PPNWF pressure sensor against applied pressure exhibited a linear region at a relatively low pressure range (~100 Pa) with sensitivity up to 18.4 kPa−1, and the sensitivity decreased to 0.7 kPa−1 at a relatively high pressure range. To demonstrate the ultra-high sensitivity of the PPNWF pressure sensor, a PEDOT-coated PVDF filament woven fabric sensor was fabricated for comparison using common filaments with diameter similar to that of the PVDF nanofiber yarns and under the same process of PEDOT polymerized coating (Figure S6). The PEDOT-coated PVDF filament woven fabric sensor showed a lower sensitivity of 4.146 kPa−1 at a pressure of ~100 Pa. We attributed the enhanced sensitivity of the PPNWF pressure sensor to the drastic change in contact area under low pressure, which is derived from its multi-level hierarchical structure (Fig. 4d). The accumulation of nanofibers, which were much higher in number compared to the filaments, deformed easily with massive protuberances of PEDOT nanoparticles, resulting in a significant increase of contact joints and the total contact area under subtle stress; thus, our prepared sensor had an ultra-high sensitivity. On the other hand, the change of contact area in the PEDOT-coated PVDF filament woven fabric sensor under pressure only depended on the contact deformation of filaments, and there was no additional submicro- or nano-structure to be deformed by applied pressure (Figure S7). The decreased sensitivity of the PPNWF pressure sensor under a pressure loading greater than 2 kPa was mainly caused by the increase in conductivity of PEDOT@PVDF nanofibers due to the nearly stable contact area under such a large pressure, which required an excessively large load to make PEDOT nanoparticles closely contact the fiber.

Therefore, the PPNWF pressure sensor had both changes in resistance and voltage under applied pressure. Simultaneous changes in voltage and resistance caused the PPNWF pressure sensor to have pressure-sensitivity, so that the sensor was in addition to be piezoresistive also piezoelectric. The total changes in current of the prepared PPNWF pressure sensor under applied pressure was shown in equation (2). It should be noted that, although applied pressure could lead to the changes in voltage and resistance at the same time, the two were not affected each other because of the different change mechanisms. Moreover, the pressure-sensitivity caused by piezoelectricity was poor compared to the piezoresistive pressure-sensitivity because the change in voltage was lower than in resistance. The sensor could generate a weak open-circuit voltage signal under applied pressure, while had a large change in resistance owing to the multi-level hierarchical structure of the sensor. Therefore, the high pressure-sensitivity of the sensor prepared in this research was mainly caused by the change in resistance.

ΔII0=U0+UR0RU0R0U0R0=1+UU01RR0 2

where U0 is the working voltage of 1 V, U is the open-circuit voltage generated by the sensor under applied pressure (mV), R0 is the initial resistance of the sensor without pressure loading (Ω), and R is the resistance under applied pressure (Ω).

Static pressures ranging from 2 Pa to 10 kPa were applied to study the static pressure response of the PPNWF pressure sensors at a working voltage of 1 V. As shown in Fig. 4b, a significant response in terms of current change was observed for the PPNWF pressure sensor under an ultra-low pressure (2–5 Pa) even under an applied voltage of 1 V, indicating that our sensor had an ultra-low pressure-detection limit. Meanwhile, the PPNWF pressure sensor also showed stable pressure sensitivity over a wide pressure range. It is obvious that the increase of applied static pressure would induce a greater change in current and, thereby, a greater pressure response. In addition, Fig. 4c shows the dynamic instantaneous current response of the PPNWF pressure sensor to varying pressure (ranging from 2 Pa to 10 kPa) under a constant working voltage of 1 V, and the response values of the current corresponded to the variation in pressure. The current almost immediately responded to a sudden external pressure and was instantly restored to the initial value at any pressure once the external pressure was removed, demonstrating the excellent response sensitivity of our sensor.

The response speed and durability, which are two important parameters for PPNWF pressure sensors, were further tested. The results of response speed for the PPNWF pressure sensor, which was tested by applying impulse pressures of 1 Hz, 10 Hz, and 25 Hz, showed that the sensor could work stably over a wide range of frequency (Fig. 4e). The PPNWF pressure sensor showed an instantaneous response with a speed of 15 ms when the frequency of applied impulse pressure was 25 Hz, which could be attributed to its unique multi-level hierarchical structure (Fig. 4f). However, the response time of the PPNWF pressure sensor increased as the frequency of applied pressure decreased, which was mainly due to a decrease of the speed for applying pressure. Furthermore, the durability of the PPNWF pressure sensor was verified by repeating loading-unloading cycles at a frequency of 25 Hz and a pressure of 10 kPa (Fig. 4g). The variation in current remained at the same level during the process of repeated loading-unloading for 7500 cycles, indicating that our sensor had excellent cycling stability and repeatability.

Our PPNWF pressure sensor could be successfully used as wearable electronic skin to detect subtle stresses sensitively and has outstanding potential for application in human health monitoring and small-scale movement detection. For demonstration, an ultra-light object, such as a piece of paper (15 mg) or a grain of beans (50 mg), was placed on the surface of the PPNWF pressure sensor, and a corresponding response in terms of an increased current was instantaneously generated (Fig. 5a). Moreover, we attached the PPNWF pressure sensor on the masseter portion of the human face to monitor muscle movement (Fig. 5b). When the subject bit teeth repeatedly, the PPNWF pressure sensor instantaneously generated a synchronized current response due to the movement of the facial masseter (Fig. 5c). If the subject slowly bit teeth, the PPNWF pressure sensor generated a slowly increasing current response because the masseter imposed a slowly increasing pressure on the sensor. However, the frequency of current response observably increased with a decreased current value when the subject bit teeth rapidly because the force imposed by the masseter decreased as the frequency increased (Movie 1). When our PPNWF pressure sensor was attached to a human throat, a significant change in current was observed as the subject sang ABC songs (Fig. 5d,e), and the tone could be distinguished according to the value of current change (Fig. 5f; Movie 2). A PPNWF pressure sensor attached to a human wrist could successfully monitor the pulse (Fig. 5g). Figure 5h shows the current change of the PPNWF pressure sensor attached to the wrist of a healthy male subject (age: 22 years, height: 178 cm, weight: 67 kg) before and after exercise. The recorded results clearly showed the pulse frequency, pulse shape, and repeatability of single pulse peaks for the subject before and after exercise. After exercise, the intensity and frequency of pulse increased significantly, and the typical percussion, tidal, and diastolic peak marked as P1, P2, and P3, respectively, in a single pulse waveform could be observed clearly (Fig. 5i). The sensor we prepared can monitor the wrist pulse, record the three typical peaks of P1, P2 and P3 in the single pulse of healthy human body with tranquility, and even distinguish the change of the pulse frequency and pulse shape for the subject before and after exercise. When the human body have potential issues or disease, such as heart disease and hypertension, its pulse must be different from the healthy body. We can use our sensor with low-pressure detection to monitor the pulse, and easily infer whether there have potential issues or disease for the human body through observing the changes of the waveform, frequency and intensity for the pulse, which could reduce unnecessary trouble. It also can be explained that our sensor has a potential application as electronic skin for human health monitoring. In summary, the PPNWF pressure sensor has the ability to detect various pressures, including ultra-low pressures, and the fabric is flexible and wearable. Thus, the sensor has a good potential for application in wearable health monitoring and the detection of human body movement. It is worth noting that the proposed method also provides an idea for the fabrication of functional electronic textiles.

Figure 5.

Figure 5

Application of PPNWF pressure sensor. (a) current response to ultra-light objects; (b,c) monitoring of muscle movement on human face; (df) monitoring of voice when people sang; (gi) current change according to wrist pulse before and after exercise.

Experimental Section

Fabrication of PVDF nanofiber yarn

PVDF nanofiber yarns were continuously prepared using the method we previously reported33. PVDF solution (16.5 wt%) was transported at a uniform rate through liquid-transport tubes to two sets of nozzles arranged symmetrically via fluid-supply apparatus (Figure S8). The nanofibers were electrospun by electric-field force and deposited in a rotary funnel to form a nanofiber web that covered the end of the funnel based on the conjugate principle of electrospinning, following which it was pulled into fiber bundles. Finally, the nanofiber yarn was obtained by twisting the fiber bundles through the rotary funnel and continuously winding the bundles with a yarn winder (Figure S9).

In-situ polymerization of EDOT on PVDF nanofiber surface

The obtained PVDF nanofiber yarns were first dipped into absolute ethanol for 24 h and then into deionized water for 30 min to displace the residual ethanol. The ethanol-treated yarns without dripping were first immersed in a mixed solution of potassium hydroxide (KOH, 2.5 mol/L) and potassium permanganate (KMnO4, 3 wt%) for 10 min, then in sodium bisulfite (NaHSO3, 2 wt%) solution until the yarn color became white, subsequently in hydrogen peroxide solution for 10 min, and finally placed in an oven for drying at 60 °C. The modified PVDF nanofiber yarns were immersed in a solution of FeCl3 in ethanol for 10 min and then dried at 60 °C. In the end, the PVDF nanofiber yarns soaked in FeCl3 oxidant were immersed in a solution of EDOT in chloroform for 20 h, then washed repeatedly with ethanol, and dried again at 60 °C to obtain PEDOT@PVDF nanofiber yarns.

Assembly of PPNWF pressure sensor

The obtained PEDOT@PVDF nanofiber yarns were used as warp and weft yarns for crisscross assembling and interlacing with each other in an over-and-under fashion for weaving into a double-layer fabric. Subsequently, a wearable nanofiber woven fabric sensor with a sandwich structure was assembled by adhering PDMS films (curing agent-to-base ratio of 1:10) with copper wires on both the upper and lower sides of the double-layer fabric. During the gradual curing of the PDMS film, the fabric with a wire on its surface was embed in the almost curing PDMS film. The wire was tightly attached to the fabric surface by the bonding of the PDMS film surface and the fabric surface.

Characterization

Field-emission scanning electron microscopy (FESEM; Hitachi S-4800, Japan) was used to examine the morphologies of the nanofiber fabrics, nanofiber yarns, and nanofibers. Transmission electron microscopy (TEM; accelerating voltage = 20 kV, Hitachi H-800, Japan) was used to study the interior structure of the PEDOT@PVDF nanofibers. X-ray photoelectron spectroscopy (XPS; Thermo Scientific ESCALAB-250, USA) with non-monochromatized Cu Kα X-rays applied as the excitation source was used to characterize the composition of the PEDOT@PVDF nanofiber. X-ray diffraction (XRD, Rigaku D-max 2200, Japan) was used to characterize the crystal structure of the PVDF power, PVDF nanofiber, and PEDOT@PVDF nanofiber by using Cu Kα radiation (λ = 0.15406 nm) applied over a 2θ range of 10°-70° at a scanning speed of 5°/min. The contact angle of the specimens was measured using a Dataphysics OCA20 (Germany) tester at room temperature and humidity. The stress intensity was measured with an INSTRON 365 tester, and the electrical response of the sensor was recorded in real time by using a Keithley 4200-SCS digital meter with a test step of 10 ms. The piezoelectric performance was recorded by using a voltage amplifier and a dynamic signal test and analysis system (DH5922N).

Conclusion

We developed a simple and effective method for the preparation of a flexible, self-powered, and wearable nanofiber fabric sensor by interweaving PEDOT@PVDF nanofiber yarns composed of PEDOT-coated PVDF nanofibers. The special multi-level hierarchical structure of the PPNWF pressure sensor yielded a high sensitivity (18.376 kPa−1 at ~100 Pa), wide pressure range (0.002–10 kPa), fast response (15 ms), and high durability (7500 cycles). In addition, the PPNWF pressure sensor could be self-powered because of the piezoelectricity of PVDF β-phase, and the output voltage exhibited a distinct switching behavior to applied pressure. We also demonstrated the use of the proposed sensor as electronic skin for monitoring subtle human motion, muscle vibration, and health in daily life. We believe our study will contribute effectually toward the development of advanced wearable pressure sensors that have potential applications as electronic skin for human health monitoring, human-machine interfaces, and biomedical prostheses.

Electronic supplementary material

Movie S1 (3.7MB, avi)
Movie S1 (2.7MB, avi)

Acknowledgements

This work was supported by a grant from the National Natural Science Foundation of China (No. 21671204, 51203196, U1204510), the Natural Science Foundation of Henan (No. 162300410339), and the Program for Science & Technology Innovation Talents in Universities of Henan Province of China (No. 15HASTIT024). The Program for Science & Technology Innovation Teams in Universities of Henan Province of China (No. 16IRTSTHN006), the Innovation Program for Academic Degree Graduate Student in University of Jiangsu Province of China (KYLX16_0797) and Plan for Scientific Innovation Talent of Henan Province is also gratefully acknowledged.

Author Contributions

Y. Zhou and J. He wrote the manuscript. Y. Zhou, J. He, H. Wang and B. Ding conceived and designed the whole experiments. Y. Zhou, K. Qi, N. Nan and X. You performed the experiments. Y. Zhou, W. Shao, L. Wang and S. Cui analyzed the data. Y. Zhou drew all the figures involved in this article. All authors reviewed the manuscript.

Competing Interests

The authors declare that they have no competing interests.

Footnotes

Electronic supplementary material

Supplementary information accompanies this paper at 10.1038/s41598-017-13281-8.

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Jianxin He, Email: hejianxin771117@163.com.

Hongbo Wang, Email: wxwanghb@163.com.

References

  • 1.Zimmerman A, Bai L, Ginty DD. The gentle touch receptors of mammalian skin. Science. 2014;346:950–954. doi: 10.1126/science.1254229. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Kim J, et al. Stretchable silicon nanoribbon electronics for skin prosthesis. Nat. Commun. 2014;5:5747–5757. doi: 10.1038/ncomms6747. [DOI] [PubMed] [Google Scholar]
  • 3.Sasaki M, et al. Highly Conductive Stretchable and Biocompatible Electrode-Hydrogel Hybrids for Advanced Tissue Engineering. Adv. Healthc. Mater. 2014;3:1919–1927. doi: 10.1002/adhm.201400209. [DOI] [PubMed] [Google Scholar]
  • 4.Park H, et al. Stretchable Array of Highly Sensitive Pressure Sensors Consisting of Polyaniline Nanofibers and Au-Coated Polydimethylsiloxane Micropillars. ACS Nano. 2015;9:9974–9985. doi: 10.1021/acsnano.5b03510. [DOI] [PubMed] [Google Scholar]
  • 5.Hammock ML, et al. 25th Anniversary Article: The Evolution of Electronic Skin (E-Skin): A Brief History, Design Considerations, and Recent Progress. Adv. Mater. 2013;25:5997–6037. doi: 10.1002/adma.201302240. [DOI] [PubMed] [Google Scholar]
  • 6.Lee JH, et al. Micropatterned P(VDF-TrFE) Film-Based Piezoelectric Nanogenerators for Highly Sensitive Self-Powered Pressure Sensors. Adv. Funct. Mater. 2015;25:3203–3209. doi: 10.1002/adfm.201500856. [DOI] [Google Scholar]
  • 7.Schwartz G, et al. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring. Nat. Commun. 2013;4:1859–1866. doi: 10.1038/ncomms2832. [DOI] [PubMed] [Google Scholar]
  • 8.Yan CY, et al. Highly Stretchable Piezoresistive Graphene-Nanocellulose Nanopaper for Strain Sensors. Adv. Mater. 2014;26:2022–2027. doi: 10.1002/adma.201304742. [DOI] [PubMed] [Google Scholar]
  • 9.Darabi MA, et al. ACS Appl. Mater. Inter. 2015. Gum Sensor: A Stretchable, Wearable, and Foldable Sensor Based on Carbon Nanotube/Chewing Gum Membrane; pp. 26195–26205. [DOI] [PubMed] [Google Scholar]
  • 10.Seyedin S, et al. ACS Appl. Mater. Inter. 2015. Knitted Strain Sensor Textiles of Highly Conductive All-Polymeric Fibers; pp. 21150–21158. [DOI] [PubMed] [Google Scholar]
  • 11.Yang TT, et al. Tactile Sensing System Based on Arrays of Graphene Woven Microfabrics: Electromechanical Behavior and Electronic Skin Application. ACS Nano. 2015;9:10867–10875. doi: 10.1021/acsnano.5b03851. [DOI] [PubMed] [Google Scholar]
  • 12.Lipomi DJ, et al. Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes. Nat. Nanotechnol. 2011;6:788–792. doi: 10.1038/nnano.2011.184. [DOI] [PubMed] [Google Scholar]
  • 13.Zang YP, et al. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection. Nat. Commun. 2011;6:6269–6277. doi: 10.1038/ncomms7269. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Zang YP, et al. Advances of flexible pressure sensors toward artificial intelligence and health care applications. Mater. Horiz. 2014;2:25–59. [Google Scholar]
  • 15.Park JW, Jang J. Fabrication of graphene/free-standing nanofibrillar PEDOT/P(VDF-HFP) hybrid device for wearable and sensitive electronic skin application. Carbon. 2015;87:275–281. doi: 10.1016/j.carbon.2015.02.039. [DOI] [Google Scholar]
  • 16.Kaltenbrunner M, et al. An ultra-lightweight design for imperceptible plastic electronics. Nature. 2013;499:458–463. doi: 10.1038/nature12314. [DOI] [PubMed] [Google Scholar]
  • 17.Park J, et al. Micro/nanostructured surfaces for self-powered and multifunctional electronic skins. Journal of Materials Chemistry B. 2016;4:2999–3018. doi: 10.1039/C5TB02483H. [DOI] [PubMed] [Google Scholar]
  • 18.Zhong WB, et al. Nanofiber based artificial electronic skin with high pressure sensitivity and 3D conformability. Nanoscale. 2016;8:12105–12112. doi: 10.1039/C6NR02678H. [DOI] [PubMed] [Google Scholar]
  • 19.Park J, et al. & Ko H. Tactile-Direction-Sensitive and Stretchable Electronic Skins Based on Human-Skin-Inspired Interlocked Microstructures. Acs Nano. 2014;8:12020–12029. doi: 10.1021/nn505953t. [DOI] [PubMed] [Google Scholar]
  • 20.Choong CL, et al. Highly Stretchable Resistive Pressure Sensors Using a Conductive Elastomeric Composite on a Micropyramid Array. Adv. Mater. 2014;26:3451–3458. doi: 10.1002/adma.201305182. [DOI] [PubMed] [Google Scholar]
  • 21.Chou HH, et al. Z.N. A chameleon-inspired stretchable electronic skin with interactive colour changing controlled by tactile sensing. Nat. Commun. 2015;6:8011–8020. doi: 10.1038/ncomms9011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Park J, et al. Fingertip skin-inspired microstructured ferroelectric skins discriminate static/dynamic pressure and temperature stimuli. Science Adv. 2015;1:e1500661. doi: 10.1126/sciadv.1500661. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lou Z, et al. An ultra-sensitive and rapid response speed graphene pressure sensors for electronic skin and health monitoring. Nano Energy. 2016;23:7–14. doi: 10.1016/j.nanoen.2016.02.053. [DOI] [Google Scholar]
  • 24.Park J, et al. Giant tunneling piezoresistance of composite elastomers with interlocked microdome arrays for ultrasensitive and multimodal electronic skins. Acs Nano. 2014;8:4689–4697. doi: 10.1021/nn500441k. [DOI] [PubMed] [Google Scholar]
  • 25.Wu XD, et al. Highly Sensitive, Stretchable, and Wash-Durable Strain Sensor Based on Ultrathin Conductive Layer@Polyurethane Yarn for Tiny Motion Monitoring. ACS Appl. Mater. Inter. 2016;8:9936–9945. doi: 10.1021/acsami.6b01174. [DOI] [PubMed] [Google Scholar]
  • 26.Ge J, et al. A Stretchable Electronic Fabric Artificial Skin with Pressure-, Lateral Strain-, and Flexion-Sensitive Properties. Adv. Mater. 2016;28:722–728. doi: 10.1002/adma.201504239. [DOI] [PubMed] [Google Scholar]
  • 27.Zhang FJ, et al. Flexible and self-powered temperature-pressure dual-parameter sensors using microstructure-frame-supported organic thermoelectric materials. Nat. Commun. 2015;6:8356–8365. doi: 10.1038/ncomms9356. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Wang Z, et al. ACS Appl. Mater. Inter. 2015. (K,Na)NbO3 Nanofiber-based Self-Powered Sensors for Accurate Detection of Dynamic Strain; pp. 4921–4927. [DOI] [PubMed] [Google Scholar]
  • 29.Young LK, Kumar GM, Sang-Woo K. Transparent flexible stretchable piezoelectric and triboelectric nanogenerators for powering portable electronics. Nano Energy. 2015;14:139–160. doi: 10.1016/j.nanoen.2014.11.009. [DOI] [Google Scholar]
  • 30.Seol ML, et al. Nature-Replicated Nano-in-Micro Structures for Triboelectric Energy Harvesting. Small. 2014;10:3887–3894. doi: 10.1002/smll.201400863. [DOI] [PubMed] [Google Scholar]
  • 31.García Núñez C, et al. Energy autonomous flexible and transparent tactile skin. Adv. Funct. Mater. 2017;27:1606287–1606298. doi: 10.1002/adfm.201606287. [DOI] [Google Scholar]
  • 32.Lai Y, et al. Electric Eel-Skin-Inspired Mechanically Durable and Super-Stretchable Nanogenerator for Deformable Power Source and Fully Autonomous Conformable Electronic-Skin Applications. Advanced Materials. 2016;28:10024–10032. doi: 10.1002/adma.201603527. [DOI] [PubMed] [Google Scholar]
  • 33.He JX, et al. Continuous twisted nanofiber yarns fabricated by double conjugate electrospinning. Fiber Polym. 2013;14:1857–1863. doi: 10.1007/s12221-013-1857-x. [DOI] [Google Scholar]
  • 34.Pandeya GP, Rastogi AC. Synthesis and characterization of pulsed polymerized poly(3,4-ethylenedioxythiophene) electrodes for high-performance electrochemical capacitors. Electrochim. Acta. 2013;87:58–168. [Google Scholar]
  • 35.Fabretto M, et al. The role of water in the synthesis and performance of vapour phase polymerised PEDOT electrochromic devices. J. Mater. Chem. 2009;19:7871–7878. doi: 10.1039/b912324e. [DOI] [Google Scholar]
  • 36.Pandey GP, Rastogi AC, Westgate CR. All-solid-state supercapacitors with poly(3,4-ethylenedioxythiophene)-coated carbon fiber paper electrodes and ionic liquid gel polymer electrolyte. J. Power Sources. 2014;245:857–865. doi: 10.1016/j.jpowsour.2013.07.017. [DOI] [Google Scholar]
  • 37.Pang C, et al. Highly Skin-Conformal Microhairy Sensor for Pulse Signal Amplification. Adv. Mater. 2015;27:634–640. doi: 10.1002/adma.201403807. [DOI] [PubMed] [Google Scholar]
  • 38.Bae GY, et al. Linearly and Highly Pressure-Sensitive Electronic Skin Based on a Bioinspired Hierarchical Structural Array. Adv. Mater. 2016;28:5300–5306. doi: 10.1002/adma.201600408. [DOI] [PubMed] [Google Scholar]
  • 39.Yoon S, et al. Metal salt-induced ferroelectric crystalline phase in poly(vinylidene fluoride) films. Macromol. Rapid Commun. 2010;29:1316–1321. doi: 10.1002/marc.200800108. [DOI] [Google Scholar]
  • 40.Chang C, et al. Direct-Write Piezoelectric Polymeric Nanogenerator with High Energy Conversion Efficiency. Nano Lett. 2010;10:726–731. doi: 10.1021/nl9040719. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Movie S1 (3.7MB, avi)
Movie S1 (2.7MB, avi)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES