AIM

To evaluate the feasibility and reliability of endoscopic transpapillary bile duct biopsy for the diagnosis of biliary strictures.

METHODS

A total of 360 patients (241 men) who underwent endoscopic retrograde cholangiopancreatography for biliary strictures with biopsy from April 2012 to March 2016 at Tokyo Medical University Hospital were retrospectively reviewed. This study was approved by our Institutional Review Board (No. 3516). Informed consent was obtained from all individual participants included in this study. The biopsy specimens were obtained using a novel slim biopsy forceps (Radial Jaw 4P, Boston Scientific, Boston, MA, United States).

RESULTS

The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 69.6%, 100%, 100%, 59.1%, and 78.8%, respectively. The sensitivity was 75.6% in bile duct cancer, 64% in pancreatic cancer, 61.1% in gallbladder cancer, and 57.1% in metastasis. In bile duct cancer, a lower sensitivity was observed for perihilar bile duct stricture (68.7%) than for distal bile duct stricture (83.1%). In terms of the stricture lengths of pancreatic cancer, gallbladder cancer, and metastasis, a longer stenosis resulted in a better sensitivity. In particular, there was a significant difference between pancreatic cancer and gallbladder cancer (P < 0.05). One major complication was perforation of the extrahepatic bile duct with bile leakage.

CONCLUSION

Endoscopic transpapillary biopsy alone using novel slim biopsy forceps is feasible and reliable, but restrictive. Biopsy should be performed in consideration of the stricture level, stricture length, and cancer type.

Keywords: Endoscopic transpapillary biopsy, Biopsy forceps, Biliary stricture, Bile duct cancer, Endoscopic retrograde cholangiography


Core tip: Various radiological imaging procedures have been established as first-line modalities for detecting biliary strictures. However, a definitive diagnosis of biliary strictures can only be established by histocytological examination. At present, there are several histocytological sampling techniques such as aspiration cytology, brush cytology, aspiration needle biopsy, and forceps biopsy. However, the optimal sampling technique remains controversial. In this study, we found that transpapillary biopsy was feasible and reliable for diagnosing biliary strictures and should be performed in consideration of the stricture level, stricture length, and cancer type.

INTRODUCTION

To date, transabdominal ultrasonography (TAUS), computed tomography (CT), magnetic resonance imaging (MRI), and magnetic resonance cholangiopancreatography (MRCP) have been established as the first-line modalities for detecting biliary strictures, being minimally invasive modalities. However, a definitive diagnosis of biliary strictures can only be established by histocytological examination, which is crucial for making a decision regarding the further management of this disease entity.

Endoscopic retrograde cholangiopancreatography (ERCP) is the most widely used close-up examination method using direct cholangiography for evaluating biliary strictures which allows transpapillary histocytological sampling from the strictures by aspiration cytology, brush cytology, and endobiliary forceps biopsy. Several studies have examined whether combining tissue sampling techniques can improve the diagnostic accuracy for biliary strictures during ERCP[1-4]. Theoretically, core tissue sampling using biopsy forceps can provide more sufficient information for diagnosing biliary strictures than cytology. However, as conventional biopsy forceps has been used in gastrointestinal tract diseases and has a thick and hard shaft, transpapillary insertion via the accessory channel of the duodenoscope is difficult.

Recently, a novel biopsy forceps which has a thin and soft shaft has been developed. Herein, we evaluated this novel slim biopsy forceps for the diagnosis of biliary strictures.

MATERIALS AND METHODS

A total of 360 patients (241 men) who underwent ERCP for biliary strictures with biopsy from April 2012 to March 2016 at Tokyo Medical University Hospital were retrospectively reviewed.

Patients were excluded in the following cases: (1) prior histological confirmation of malignancy; (2) postoperative biliary strictures; (3) ampullary tumor; and (4) less than 6 mo of follow-up in patients with negative malignant results. The final diagnosis was established by histopathological examination of tissues obtained endoscopically or surgically. If the histopathological diagnosis was negative for carcinoma, a clinical diagnosis was made from the clinical course for over 6 mo or more and several radiological image findings from various imaging modalities such as TAUS, CT, MRI, MRCP, and endoscopic ultrasonography (EUS). If biopsy forceps failed to achieve a definitive diagnosis and biliary strictures or filling defects were still indeterminate even with the use of various radiological modalities, peroral cholangioscopy was performed for a definitive diagnosis.

ERCP was performed using the standard technique with a duodenoscope. When biliary strictures were identified under radiographic guidance, endoscopic sphincterotomy (EST) was performed before tissue sampling. The biopsy specimens were obtained using a novel slim biopsy forceps (Radial Jaw 4P, Boston Scientific, Boston, MA, United States) (Figure 1A, video 1). The forceps was transpapillary advanced to the distal end of the stricture alongside the guidewire. The obtained specimen was immediately fixed in 10% formalin. All procedures were performed by operators with experience of more than 100 ERCP cases per year.

Figure 1.

Figure 1

Biopsy forceps. A: Radial Jaw 4P; B: Swing function.

This study was approved by our Institutional Review Board (No. 3516) and informed consent was obtained from all individual participants included in this study.

Statistical analysis

Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were calculated. Statistical analyses were performed using StatMate III (ATMS, Tokyo, Japan). A P-value < 0.05 was considered to indicate a statistically significant difference.

RESULTS

The characteristics of the patients are shown in Table 1. Their median age was 71 ± 11.8 years (range: 17-95 years). The diseases were bile duct cancer in 132 patients, pancreatic cancer in 86, gallbladder cancer in 18, metastasis of other cancers in 14, and benign biliary stricture in 110. Among the patients with metastases, the primary sites were as follows: colon cancer in 3 patients, gastric cancer in 2, pancreatic cancer in 2, lung cancer in 2, breast cancer in 2, ovarian cancer in 2, and cholangiocellular carcinoma in 1.

Table 1.

Patient characteristics

Patient characteristics
Number of patients 360
Age [mean ± SD (range), yr] 71 ± 11.8 (17-95)
Sex, male/female 241/119
Disease (number of patients)
Bile duct cancer 132
Pancreatic cancer 86
Gallbladder cancer 18
Metastasis 14
Benign stricture 110

Sample collection rate

The biopsy forceps could be inserted via the papilla after EST, and the specimens evaluated were collected from all 360 patients (technical success: 100%), with 820 bites in total (range: 1-6 bites). The mean number of biopsies was 2.28 ± 0.91 (Table 2).

Table 2.

Overall diagnostic ability in all cases (n = 360)

Sample collection rate
Total number of biopsies 820
Mean number of biopsies, ± SD (range) 2.28 ± 0.91 (1-6)
Overall results
Sensitivity 69.6%
Specificity 100%
PPV 100%
NPV 59.1%
Accuracy 78.8%

PPV: Positive predictive value; NPV: Negative predictive value.

Overall results

The sensitivity, specificity, PPV, NPV, and accuracy were 69.6%, 100%, 100%, 59.1%, and 78.8%, respectively (Table 2). The sensitivity was 75.6% in bile duct cancer, 64% in pancreatic cancer, 61.1% in gallbladder cancer, and 57.1% in metastasis (Table 3).

Table 3.

Overall sensitivity for malignancy

Diagnosis n Sensitivity
Bile duct cancer 100/132 75.6%
Pancreatic cancer 55/86 64.0%
Gallbladder cancer 11/18 61.1%
Metastasis 8/14 57.1%

Type of cancers

The examination results for bile duct cancer are shown in Table 4. According to the stricture level of bile duct cancer, the sensitivity was 68.7% in the perihilar bile duct and 83.1% in the distal bile duct; 95% in the middle and 76.7% in the lower. Furthermore, comparing the type of stricture with space that the biopsy forceps could open with the type of stricture without space in the lower bile duct (Figure 2), the sensitivity with an open space was 84.6% and that without an open space was 64.7%.

Table 4.

Sensitivity of biopsy forceps in bile duct cancer

n Sensitivity
Total 100/132 75.60%
Site of stricture
Perihilar bile duct 46/67 68.7%
Distal bile duct 54/65 83.1%
Middle 21/22 95%
Lower 33/43 76.7%
(Open space + 22/26 84.6%
(Open space − 11/17 64.7%

Figure 2.

Figure 2

Fluoroscopic images during endoscopic retrograde cholangiopancreatography. A: Stricture with an open space; B: Stricture without an open space.

The examination results for extrinsic neoplasms are shown in Table 5. As for pancreatic cancer according to the stricture level, the sensitivity was 45.5% in the middle bile duct and 66.7% in the lower bile duct. In addition, according to the localization of the primary tumor, the sensitivity was 68.4% in pancreatic head cancer and 30% in pancreatic body cancer. As for gallbladder cancer according to the stricture level, the sensitivity was 54.5% in the perihilar bile duct and 71.4% in the distal bile duct. As for metastasis according to the stricture level, the sensitivity was 66.7% in the perihilar bile duct and 50% in the distal bile duct.

Table 5.

Sensitivity of biopsy forceps in extrinsic neoplasms

n Sensitivity
Pancreatic cancer 55/86 64.0%
Site of stricture
Middle bile duct 5/11 45.5%
Lower bile duct 50/75 66.7%
Localization of tumor
Head 52/76 68.4%
Body 3/10 30.0%
Gallbladder cancer 11/18 61.1%
Site of stricture
Perihilar bile duct 6/11 54.5%
Distal bile duct 5/7 71.4%
Metastasis 8/14 57.1%
Site of stricture
Perihilar bile duct 4/6 66.7%
Distal bile duct 4/8 50.0%

Length of stricture in cancers

Apart from the stricture level, the mean stricture lengths were 16.9 mm, 22 mm, and 17.1 mm in the biopsy-positive group and 13.5 mm, 13.4 mm, and 13.2 mm in the biopsy-negative group for pancreatic cancer, gallbladder cancer, and metastasis, respectively (Table 6). The biopsy-positive group tended to have a longer stricture length than the biopsy-negative group. In particular, there was a significant difference between pancreatic cancer and gallbladder cancer (P < 0.05).

Table 6.

Mean stricture lengths in extrinsic neoplasms

Positive (mm) Negative (mm) P value
Pancreatic cancer 16.9 13.5 < 0.05
Gallbladder cancer 22 13.4 < 0.05
Metastasis 17.1 13.2 NS

NS: Not significant.

Procedure-related adverse events

There were no procedure-related adverse events, although there was 1 patient with perihilar bile duct cancer in whom perforation of the distal bile duct with bile leakage was observed. The condition was improved only by temporary endoscopic nasobiliary drainage tube placement.

DISCUSSION

In this study, we found that transpapillary biopsy using a novel slim biopsy forceps could be easily and safely performed and was effective for diagnosing biliary strictures.

At present, there are several cytological and histological sampling techniques such as aspiration cytology, brush cytology, aspiration needle biopsy, and forceps biopsy. However, the optimal sampling technique remains controversial. The ideal technique for obtaining tissue for a definitive diagnosis of malignant biliary strictures should be simple, safe, and effective with a high sensitivity and specificity.

Although bile cytology is easy, its accuracy range is very low (6%-32%)[5,6]. Mohandas et al[7]. described that bile cytology with dilation of biliary strictures up to 10-Fr during ERCP enhanced its sensitivity by 63% compared with the 27% sensitivity of bile cytology without dilation. Regarding brush cytology, although this can be undertaken relatively easily and safely in a short time, its sensitivity is still considered to be low (30%-57%)[1-3]. Farrell et al[8] reported that the sensitivity of brush cytology increased by 85% after stricture dilation and endoscopic needle aspiration compared with the 57% sensitivity of brush cytology alone. In contrast, de Bellis et al[9] suggested that stricture dilation did not improve the sensitivity of brush cytology for cancer detection. Hence, the efficacy of stricture dilation for diagnosis is still controversial.

On the other hand, transpapillary forceps biopsy has not been widely used because it is thought to be technically difficult, resulting in a waste of time. Moreover, its sensitivity is very variable (15%-81%)[1-3,10-14] (Table 7). In 2002, de Bellis et al[9] summarized 502 previously reported cases and found that the sensitivity and specificity of transpapillary forceps biopsy were 56% (43%-81%) and 97% (90%-100%), respectively. Their report showed that the diagnostic performance of forceps biopsy was higher than that of other tissue sampling methods[15,16]. Furthermore, forceps biopsy is useful not only for the diagnosis of malignant/benign tumors but also for the selection of therapeutic methods (e.g., chemotherapy) based on the histological types of cancer, and the judgment of the superficial intraductal spread of bile duct cancer.

Table 7.

Characteristics of studies evaluating bile duct biopsies

Study Year Sample size (n) Sensitivity, %
Pugliese et al[1] 1995 94 53
Ponchon et al[3] 1995 233 43
Howell et al[10] 1996 28 15
Sugiyama et al[11] 1996 52 81
Jailwala et al[2] 2000 133 37
Rösch et al[12] 2004 50 36
Kitajima et al[13] 2007 60 65
Weber et al[14] 2008 58 53
Our case 2016 360 70

In the present study, we used a novel slim biopsy forceps (Radial Jaw 4P, Boston Scientific) (Figure 1A). The Radial Jaw series are the world’s first disposable biopsy forceps released in 1991. The first type of Radial Jaw had a diameter of 2.2 mm and had tiny teeth around the cup. After repeated improvements, the present Radial Jaw 4P was released in 2011. Radial Jaw 4P has a thinner shaft of 1.8 mm, a wire with a sheath to pass through the scope smoothly, and an open width/angle of 5.4 mm/150°. In addition, its thinner cup increases sampling capacity and its swing function helps achieve tangential biopsy (Figure 1B). Sufficient tissue samples for a definitive diagnosis, which include the mucosal cancer or invasive cancer below the bile duct epithelium, can be obtained using this forceps (Figure 3). Hence, the present Radial Jaw 4P may be more appropriate for performing optimal biopsy. In fact, in the present study, this novel forceps could collect adequate specimens for evaluation from all of the patients. Thus, our data showed a higher sensitivity than previous studies of bile duct biopsies (Table 7), suggesting that this novel slim biopsy forceps appears suitable as a tissue sampling device for the diagnosis of biliary strictures.

Figure 3.

Figure 3

Biopsy specimens obtained using Radial Jaw 4P. The biopsy specimen obtained was sufficient and included adenocarcinoma. A: Bile duct cancer; B: Pancreatic cancer (HE. stain, × 10).

Regarding bile duct cancer, a lower sensitivity was observed for the perihilar bile duct stricture than for the distal bile duct stricture. This may be due to the narrow and smooth stricture and the distance from the papilla, preventing the biopsy forceps from being able to sufficiently open the stricture and precisely hitting the tumor. In contrast, a better sensitivity was observed for the distal bile duct stricture, particularly in the middle bile duct. For the lower bile duct, a better sensitivity was observed for the stricture with an open space than for the stricture without an open space. In the stricture without an open space for a biopsy forceps to open sufficiently, adequate and accurate biopsy tissue samplings from the target site may be slightly difficult.

Thus far, some reports have shown that the combination of brush cytology and forceps biopsy improved sensitivity[3,8,10]. However, a recent systematic review and a meta-analysis have suggested that the combination of brush cytology and forceps biopsy only modestly increased sensitivity[17]. These combination techniques may be ideal because the tumor is usually exposed to the bile duct surface, allowing brush cytology to obtain cells from the entire lumen surface in bile duct cancer, particularly in severe strictures of the perihilar bile duct and lower bile duct without an open space. On the other hand, the sensitivity of biopsy in pancreatic cancer was lower than that in bile duct cancer similarly to previous reports[1,3,11,18]. Theoretically, tumor cells from the surface of the bile duct in pancreatic cancer appear to be fewer than tumor cells in bile duct cancer. Thus, sensitivity in pancreatic cancer as well as in gallbladder cancer and metastases, namely, “extrinsic neoplasms”, appears to be limited even with the use of additional brush cytology in combination with biopsy forceps. Interestingly, some reports[3,19] have also demonstrated that improvement of sensitivity cannot be expected with the combination of aspiration cytology and brush cytology for cancers with a bile duct stricture by extrinsic exclusion.

Furthermore, the sensitivity for a stricture in pancreatic body cancer was lower than that for a stricture in pancreatic head cancer. This is the reason why the bile duct stricture in pancreatic body cancer, which even shows a biliary stricture that is far from the bile duct, occurs not by direct invasive reaction but as a secondary fibrous cicatricial stricture by stromal reaction. In addition, many pancreatic body cancers occur in the middle bile duct stricture, resulting in a lower sensitivity for the middle bile duct stricture.

In the present study, we showed that a longer stricture had a better sensitivity for diagnosis. This suggests an increase in the positive diagnostic rate of forceps biopsy because the contact area with the bile duct of extrinsic cancer becomes wider according to the stricture length. Hence, to increase the diagnostic accuracy, multiple biopsies appear necessary for the diagnosis of a shorter biliary stricture due to extrinsic cancers.

Recently, EUS-FNA has been introduced for evaluating biliary strictures[12,20]. EUS-FNA may be a preferable method for tissue sampling of neoplasms of extrinsic origin such as pancreatic cancer, gallbladder cancer, and metastasis after obtaining negative or nondiagnostic ERCP tissue sampling results. On the other hand, ERCP-based tissue sampling may be better for bile duct cancer of biliary epithelial origin.

Pancreatitis and cholangitis are generally observed, although their incidence is low and their severity is mild in most cases requiring only conservative treatment[2,21]. Although rare, bile duct perforation can occur during forceps biopsy[1]. Repeated biopsies at the same site may account for the perforation. In the present study, 1 case of perforation of the extrahepatic bile duct with bile leakage occurred during forceps biopsy in a patient with perihilar bile duct cancer. Although Radial Jaw 4P is a soft biopsy forceps, care should be taken during its usage.

Various tips in performing forceps biopsy have been reported. Of interest is the study of Tamada et al[22] which suggested factors for a successful bile duct biopsy under percutaneous transhepatic cholangioscopy (PTCS) from the viewpoint of the growth type of bile duct cancers. They recommended that 2 biopsy samples should be obtained from the mass in polypoid-type bile duct cancers and from the margin in stenotic-type bile duct cancers with a dilated vessel. Moreover, 3 biopsy samples should be obtained from the margin of the stricture in stenotic-type bile duct cancers without a dilated vessel, and biopsy specimens should be obtained from within the stricture in pancreatic cancer. Hence, transpapillary bile duct biopsy is performed under fluoroscopic guidance and is not similar to the biopsy performed under direct vision by PTCS. Thus, more than 3 biopsy specimens may be necessary and the biopsy sites, such as the margin of the stricture or within the stricture, should be considered according to the types of cancers such as cancers of biliary epithelial or extrinsic origin.

The limitations of this study were its retrospective nature, the lack of a control group, and the inclusion of a single-center experience.

In conclusion, endoscopic transpapillary biopsy using a novel slim biopsy forceps is feasible and reliable, but is a restrictive method for tissue sampling of malignant biliary strictures. When performing the biopsy, it is necessary to consider the stricture levels, stricture lengths, and types of cancers such as cancers of biliary epithelial or extrinsic origin to improve the diagnosis of malignant biliary strictures.

COMMENTS

Background

There are several cytological and histological sampling techniques for a definitive diagnosis of malignant biliary strictures. However, the optimal sampling technique remains controversial. The ideal technique should be simple, safe, and effective with a high sensitivity and specificity.

Research frontiers

Transpapillary forceps biopsy has not been widely used because it is thought to be technically difficult, resulting in a waste of time. Moreover, its sensitivity is very variable (15%-81%). In the present study, a novel slim biopsy forceps could collect adequate specimens for evaluation from all of the patients and our data showed a higher sensitivity (70%) than previous studies of bile duct biopsies.

Innovations and breakthroughs

It is necessary to consider the stricture levels, stricture lengths, and types of cancers such as cancers of biliary epithelial or extrinsic origin to improve the diagnosis of malignant biliary strictures.

Applications

Endoscopic transpapillary biopsy using a novel slim biopsy forceps is feasible and reliable.

Terminology

Endoscopic transpapillary biopsy for diagnosis of biliary strictures should be performed in consideration of the stricture level, stricture length, and cancer type.

Peer-review

The paper deals with the problem of obtaining reliable biopsies from lesions in the biliary tree. Evidently the methods described here yields a progress in this field. The paper is well written. This is good study exploring the efficacy and diagnostic value of a new slim forceps by Boston. The manuscript is generally interesting and offers useful clinical information to those who carry out endoscopic retrograde cholangiopancreatography.

Footnotes

Manuscript source: Unsolicited manuscript

Specialty type: Gastroenterology and hepatology

Country of origin: Japan

Peer-review report classification

Grade A (Excellent): 0

Grade B (Very good): B, B, B

Grade C (Good): C, C, C

Grade D (Fair): 0

Grade E (Poor): 0

Institutional review board statement: This study was reviewed and approved by our institutional review board (Tokyo Medical University No. 3516).

Informed consent statement: Patients were not required to give informed consent to the study because the analysis used anonymous clinical data that were obtained after each patient agreed to treatment by written consent. For full disclosure, the details of the study are published on the home page of Tokyo Medical University.

Conflict-of-interest statement: We have no financial relationships to disclose.

Data sharing statement: No additional data are available.

Peer-review started: March 20, 2017

First decision: June 8, 2017

Article in press: August 2, 2017

P- Reviewer: Bramhall S, Hussain A, Kreisel W, Lee HC, Neri V, Garcia-Olmo D S- Editor: Ma YJ L- Editor: A

E- Editor: Huang Y

Contributor Information

Kenjiro Yamamoto, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Takayoshi Tsuchiya, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Takao Itoi, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan. itoi@tokyo-med.ac.jp.

Shujiro Tsuji, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Reina Tanaka, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Ryosuke Tonozuka, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Mitsuyoshi Honjo, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Shuntaro Mukai, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Kentaro Kamada, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Mitsuru Fujita, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Yasutsugu Asai, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Yukitoshi Matsunami, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Yuichi Nagakawa, Third Department of Surgery, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Hiroshi Yamaguchi, Department of Pathology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

Atsushi Sofuni, Department of Gastroenterology and Hepatology, Tokyo Medical University, Shinjuku-ku, Tokyo 160-0023, Japan.

References

  • 1.Pugliese V, Conio M, Nicolò G, Saccomanno S, Gatteschi B. Endoscopic retrograde forceps biopsy and brush cytology of biliary strictures: a prospective study. Gastrointest Endosc. 1995;42:520–526. doi: 10.1016/s0016-5107(95)70004-8. [DOI] [PubMed] [Google Scholar]
  • 2.Jailwala J, Fogel EL, Sherman S, Gottlieb K, Flueckiger J, Bucksot LG, Lehman GA. Triple-tissue sampling at ERCP in malignant biliary obstruction. Gastrointest Endosc. 2000;51:383–390. doi: 10.1016/s0016-5107(00)70435-4. [DOI] [PubMed] [Google Scholar]
  • 3.Ponchon T, Gagnon P, Berger F, Labadie M, Liaras A, Chavaillon A, Bory R. Value of endobiliary brush cytology and biopsies for the diagnosis of malignant bile duct stenosis: results of a prospective study. Gastrointest Endosc. 1995;42:565–572. doi: 10.1016/s0016-5107(95)70012-9. [DOI] [PubMed] [Google Scholar]
  • 4.Umeda J, Itoi T. Current status of preoperative biliary drainage. J Gastroenterol. 2015;50:940–954. doi: 10.1007/s00535-015-1096-6. [DOI] [PubMed] [Google Scholar]
  • 5.Davidson B, Varsamidakis N, Dooley J, Deery A, Dick R, Kurzawinski T, Hobbs K. Value of exfoliative cytology for investigating bile duct strictures. Gut. 1992;33:1408–1411. doi: 10.1136/gut.33.10.1408. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kurzawinski TR, Deery A, Dooley JS, Dick R, Hobbs KE, Davidson BR. A prospective study of biliary cytology in 100 patients with bile duct strictures. Hepatology. 1993;18:1399–1403. [PubMed] [Google Scholar]
  • 7.Mohandas KM, Swaroop VS, Gullar SU, Dave UR, Jagannath P, DeSouza LJ. Diagnosis of malignant obstructive jaundice by bile cytology: results improved by dilating the bile duct strictures. Gastrointest Endosc. 1994;40:150–154. doi: 10.1016/s0016-5107(94)70157-1. [DOI] [PubMed] [Google Scholar]
  • 8.Farrell RJ, Jain AK, Brandwein SL, Wang H, Chuttani R, Pleskow DK. The combination of stricture dilation, endoscopic needle aspiration, and biliary brushings significantly improves diagnostic yield from malignant bile duct strictures. Gastrointest Endosc. 2001;54:587–594. doi: 10.1067/mge.2001.118715. [DOI] [PubMed] [Google Scholar]
  • 9.de Bellis M, Fogel EL, Sherman S, Watkins JL, Chappo J, Younger C, Cramer H, Lehman GA. Influence of stricture dilation and repeat brushing on the cancer detection rate of brush cytology in the evaluation of malignant biliary obstruction. Gastrointest Endosc. 2003;58:176–182. doi: 10.1067/mge.2003.345. [DOI] [PubMed] [Google Scholar]
  • 10.Howell DA, Parsons WG, Jones MA, Bosco JJ, Hanson BL. Complete tissue sampling of biliary strictures at ERCP using a new device. Gastrointest Endosc. 1996;43:498–502. doi: 10.1016/s0016-5107(96)70294-8. [DOI] [PubMed] [Google Scholar]
  • 11.Sugiyama M, Atomi Y, Wada N, Kuroda A, Muto T. Endoscopic transpapillary bile duct biopsy without sphincterotomy for diagnosing biliary strictures: a prospective comparative study with bile and brush cytology. Am J Gastroenterol. 1996;91:465–467. [PubMed] [Google Scholar]
  • 12.Rösch T, Hofrichter K, Frimberger E, Meining A, Born P, Weigert N, Allescher HD, Classen M, Barbur M, Schenck U, et al. ERCP or EUS for tissue diagnosis of biliary strictures? A prospective comparative study. Gastrointest Endosc. 2004;60:390–396. doi: 10.1016/s0016-5107(04)01732-8. [DOI] [PubMed] [Google Scholar]
  • 13.Kitajima Y, Ohara H, Nakazawa T, Ando T, Hayashi K, Takada H, Tanaka H, Ogawa K, Sano H, Togawa S, et al. Usefulness of transpapillary bile duct brushing cytology and forceps biopsy for improved diagnosis in patients with biliary strictures. J Gastroenterol Hepatol. 2007;22:1615–1620. doi: 10.1111/j.1440-1746.2007.05037.x. [DOI] [PubMed] [Google Scholar]
  • 14.Weber A, von Weyhern C, Fend F, Schneider J, Neu B, Meining A, Weidenbach H, Schmid RM, Prinz C. Endoscopic transpapillary brush cytology and forceps biopsy in patients with hilar cholangiocarcinoma. World J Gastroenterol. 2008;14:1097–1101. doi: 10.3748/wjg.14.1097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.De Bellis M, Sherman S, Fogel EL, Cramer H, Chappo J, McHenry L Jr, Watkins JL, Lehman GA. Tissue sampling at ERCP in suspected malignant biliary strictures (Part 1) Gastrointest Endosc. 2002;56:552–561. doi: 10.1067/mge.2002.128132. [DOI] [PubMed] [Google Scholar]
  • 16.de Bellis M, Sherman S, Fogel EL, Cramer H, Chappo J, McHenry L Jr, Watkins JL, Lehman GA. Tissue sampling at ERCP in suspected malignant biliary strictures (Part 2) Gastrointest Endosc. 2002;56:720–730. doi: 10.1067/mge.2002.129219. [DOI] [PubMed] [Google Scholar]
  • 17.Navaneethan U, Njei B, Lourdusamy V, Konjeti R, Vargo JJ, Parsi MA. Comparative effectiveness of biliary brush cytology and intraductal biopsy for detection of malignant biliary strictures: a systematic review and meta-analysis. Gastrointest Endosc. 2015;81:168–176. doi: 10.1016/j.gie.2014.09.017. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Kubota Y, Takaoka M, Tani K, Ogura M, Kin H, Fujimura K, Mizuno T, Inoue K. Endoscopic transpapillary biopsy for diagnosis of patients with pancreaticobiliary ductal strictures. Am J Gastroenterol. 1993;88:1700–1704. [PubMed] [Google Scholar]
  • 19.Lee SJ, Lee YS, Lee MG, Lee SH, Shin E, Hwang JH. Triple-tissue sampling during endoscopic retrograde cholangiopancreatography increases the overall diagnostic sensitivity for cholangiocarcinoma. Gut Liver. 2014;8:669–673. doi: 10.5009/gnl13292. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.DeWitt J, Misra VL, Leblanc JK, McHenry L, Sherman S. EUS-guided FNA of proximal biliary strictures after negative ERCP brush cytology results. Gastrointest Endosc. 2006;64:325–333. doi: 10.1016/j.gie.2005.11.064. [DOI] [PubMed] [Google Scholar]
  • 21.Ryan ME. Cytologic brushings of ductal lesions during ERCP. Gastrointest Endosc. 1991;37:139–142. doi: 10.1016/s0016-5107(91)70671-8. [DOI] [PubMed] [Google Scholar]
  • 22.Tamada K, Kurihara K, Tomiyama T, Ohashi A, Wada S, Satoh Y, Miyata T, Ido K, Sugano K. How many biopsies should be performed during percutaneous transhepatic cholangioscopy to diagnose biliary tract cancer? Gastrointest Endosc. 1999;50:653–658. doi: 10.1016/s0016-5107(99)80014-5. [DOI] [PubMed] [Google Scholar]

Articles from World Journal of Gastroenterology are provided here courtesy of Baishideng Publishing Group Inc

RESOURCES