Abstract
Seasonal variation of air pollution is associated with variety of seasons and specificity of particular months which form the so-called summer and winter season also known as the “heating” season. The occurrence of higher values of air pollution in different months of a year is associated with the type of climate, and accordingly with different atmospheric conditions in particular months, changing state of weather on a given day, and anthropogenic activity. The appearance of these conditions results in different levels of air pollution characteristic for a given period. The study uses data collected during a seven-year period (2009–2015) in the automatic measuring station of immissions located in Eastern Wielkopolska. The analysis concerns the average and maximum values of air pollution (i.e., particulate matter PM10, sulfur dioxide, nitrogen dioxide, carbon monoxide, and ozone) from the perspective of their occurrence in particular seasons and months or in relation to meteorological actors such as temperature, humidity, and wind speed.
Keywords: Dispersion, Summer and winter season, Air quality
Introduction
Air quality in both Poland and other countries of the world depends on the amount of pollutant emissions, the intensity and type of physicochemical changes taking place in the atmosphere, and the large-scale movements of polluted air masses. Atmospheric air is an element of the natural environment for which no natural protective barriers can be isolated, and therefore, the control and analysis of the impact of particular pollutants not only on a global but also continental, national, and local scale are essential (Cichowicz and Wielgosiński 2015a, b; Ménard et al. 2016; Vallero 2014). The problem of air quality was noted by the World Health Organization (WHO), which estimated in 2012 that about 7 million deaths were associated with living in the areas with polluted air. The most important legislative act defining the requirements for air protection for all EU member states is Directive 2008/50/EC of the European Parliament and Council of 21 May 2008 on air quality and cleaner air for Europe called Clean Air for Europe (CAFE). Its aim is to improve air quality and protect against the harmful effects of pollution on the environment.
Sources of air pollutants are mainly combustion processes, various technological processes as well as vehicle traffic (Cichowicz and Wielgosiński 2015a, b; Gurney et al. 2012; Lelieveld et al. 2015; Nemitz et al. 2002). It should be borne in mind at the same time that low-emission sources emit pollutants primarily during the heating season, and that remote systems do it with varying intensity throughout the entire calendar year (Cichowicz and Wielgosiński 2015a, b; Lin et al. 2011).
Since the emitted pollutants are subjected to both dispersion and advection in the air, the analysis of such phenomena should take into account both the wind speed and direction, vertical movements of air due to thermodynamic equilibrium of the atmosphere, and local turbulences caused by altitude contrasts in the land cover. As a result of the dispersion of pollutants emitted to the air, the determined concentrations of pollutants are formed on the Earth’s surface, which are related to the limit values specified in national and international law (Colls 2002).
Experimental
The analyses used data from a seven-year period covering the years 2009–2015, originating from an automatic atmospheric air monitoring station, located in the eastern part of Wielkopolska, in the Konin district, in the municipality of Ślesin in Piotrkowice (Fig. 1). The Konin district covers an area of 1578.7 km2 with a population density of about 82 persons/km2. The surrounding area is primarily arable land and meadows. The nearest human settlements are located in the following distances: 0.6 km—Piotrkowice village (532 inhabitants), 1.5 km—Wygoda village (270 inhabitants), 2.1 km—Niedźwiady Duże village (163 inhabitants), and 3.1 km—Półwiosek Stary village (263 inhabitants) as well as about 3.5 km—town of Ślesin (about 3200 inhabitants) and 4.2 km—town of Licheń (about 1500 inhabitants). The natural resource of the region is primarily lignite, whose mining has been taking place in the northern part of the region for over 70 years and is used as fuel in power plants “Pątnów I”, “Pątnów II”, and “Konin”, which are parts of the Pątnów-Adamów-Konin Power Plant Complex—ZE PAK S.A.
To illustrate the hypothetical scale of environmental impact of the plants, the average amount of combusted lignite, biomass, fuel oil, and the amount of electricity and heat produced in the analyzed period is presented in Tables 1 and 2. This was compared with the mean annual concentrations of pollutants emitted.
Table 1.
Year | Electric energy production | Heat energy production | Coal consumption | Mazut consumption | Biomass consumption |
---|---|---|---|---|---|
GWh/year | TJ/year | Gg/year | Gg/year | Gg/year | |
Pątnów I Power Plant | |||||
2009 | 5239 | no data | 6316 | 8222 | 108,662 |
2010 | 4480 | 106 | 5461 | 9360 | 149,204 |
2011 | 4859 | 151 | 6113 | 9929 | 77,203 |
2012 | 5140 | 153 | 6450 | 13,193 | 164,863 |
2013 | 5076 | 129 | 6576 | 13,772 | 36,710 |
2014 | 4501 | 146 | 5827 | 6934 | 0 |
2015 | 4532 | 178 | 6004 | 7074 | 0 |
Pątnów II Power Plant | |||||
2009 | 2213 | – | 2180 | 1278 | 0 |
2010 | 2512 | – | 2478 | 1624 | 0 |
2011 | 2429 | – | 2447 | 849 | 0 |
2012 | 2807 | – | 2942 | 703 | 0 |
2013 | 2650 | – | 2782 | 1 295 | 0 |
2014 | 2558 | – | 2725 | 1184 | 0 |
2015 | 2228 | – | 2425 | 779 | 0 |
Konin Heating and Power Plant | |||||
2009 | 675 | 1595 | 900 | 1385 | 217,863 |
2010 | 574 | 1750 | 841 | 973 | 219,395 |
2011 | 451 | 1458 | 674 | 383 | 118 223 |
2012 | 392 | 1496 | 673 | 621 | 24,448 |
2013 | 411 | 1497 | 765 | 376 | 0 |
2014 | 416 | 1340 | 801 | 298 | 0 |
2015 | 388 | 1314 | 713 | 459 | 0 |
Table 2.
Year | TSP | SO2 | NO2 | CO |
---|---|---|---|---|
Mg/year | Mg/year | Mg/year | Mg/year | |
Pątnów I Power Plant | ||||
2009 | 459 | 8037 | 8230 | 780 |
2010 | 390 | 6262 | 6298 | 686 |
2011 | 456 | 7721 | 6674 | 384 |
2012 | 467 | 7499 | 7447 | 448 |
2013 | 650 | 6630 | 7429 | 330 |
2014 | 587 | 5240 | 7031 | b.d. |
2015 | 338 | 5199 | 6721 | b.d. |
Pątnów II Power Plant | ||||
2009 | 92 | 1413 | 1413 | 220 |
2010 | 108 | 1012 | 1770 | 203 |
2011 | 108 | 1190 | 1755 | 242 |
2012 | 121 | 1518 | 2080 | 264 |
2013 | 116 | 1698 | 2101 | 259 |
2014 | 98 | 1337 | 1894 | b.d. |
2015 | 74 | 1149 | 1654 | b.d. |
Konin Heating and Power Plant | ||||
2009 | 69 | 1222 | 1613 | 557 |
2010 | 71 | 1693 | 1388 | 520 |
2011 | 91 | 1061 | 1050 | 388 |
2012 | 81 | 1374 | 1129 | 277 |
2013 | 71 | 1304 | 1296 | 56 |
2014 | 86 | 1565 | 1312 | b.d. |
2015 | 69 | 1376 | 1382 | b.d. |
The air monitoring station is located in a 2.5 × 3.0 m container 2.5 m high, which is resistant to external weather conditions. The following pollutants have been measured: particulate matter PM10 (in concentrations ranging from 5.0 μg/m3 to 250 mg/m3), sulfur dioxide (0 to 500 ppb), carbon monoxide (0 to 50 ppm), nitrogen oxide (0 to 500 ppb), nitrogen dioxide (0 to 500 ppb), nitrogen oxides NOx, as the sum of NO and NO2 (0 to 500 ppb), and ozone (0 to 500 ppb). Thermo Scientific’s primary monitoring system was provided by the monitoring station. PM10 particulate matter measurement was carried out using a TEOM 1400a type analyzer based on a gas sample filtration system and automatic mass measurement. Sulfur dioxide concentrations were measured using an automatic Thermo 43i UV spectrometer. Nitrogen oxides (NO and NO2) are measured by a Thermo 42i chemiluminescent analyzer, and the carbon monoxide concentration is measured using an Thermo 48i IR spectrometer. Measurement of ozone concentration was provided by optical method at 254 nm (UV) using Thermo 49i analyzer.
All measurements of pollutants are made by analyzers whose measurement methods are in accordance with the reference methods specified in Annex VI of the CAFE Directive. Devices operate 24 h a day, only with small interruptions (about 1% of the time) dedicated to servicing and calibration.
Measurements of some meteorological parameters are also carried out at the station to determine the direction of flowing air masses and potential sources of pollution. They are made by means of two sensors that measure such air parameters as temperature (°C), relative humidity (%), wind direction (0–359°), and wind speed (m/s). The HMP 45A sensor produced by Vaisala is used to measure the temperature and humidity of the air. It was mounted in the meteorological radiation shield, while wind direction and wind speed measurements were carried out using a WindSonic ultrasonic sensor from GILL Instruments installed at the top of a 12-m meteorological mast.
Results and discussion
For analysis, the results of measurements of air pollution and meteorological data recorded by the Piotrkowice measuring station in the seven-year period (2009–2015) were selected. It was assumed that the results of averaged individual measurements from the seven-year period would be analyzed. It was also assumed that the best way to express changes in concentrations recorded at the station would be to analyze their maximum values in terms of seasonality of emissions, including variations in recorded concentrations depending on direction and speed of wind and air temperature and humidity. Depending on the pollutant analyzed and its permissible values, 24-h, 1-h, or 8-h rolling averaging was used.
Figure 2 shows averaged daily concentrations of PM10 for both individual months and the average for the years 2009–2015. Similarly, Fig. 3 shows the average sulfur dioxide concentration for each month and the average for 2009–2015. On the other hand, the permissible level for nitrogen dioxide is the instantaneous (1 h) value of 200 μg/m3, so Fig. 4 shows the averages of the maximum instantaneous values from individual months in the seven-year period analyzed. A further analysis of the seasonality of air pollutants concerned carbon monoxide (Fig. 5), in which the recorded concentrations were referred to a permissible level of 10,000 μg/m3 and defined as an 8-h rolling average.
On the other hand, the permissible level for ozone (Fig. 6) is 120 μg/m3, which is the maximum concentration that can occur on a given day, out of all 8-h rolling values of a given day. Figures 7, 8 and 9 show the analysis of meteorological conditions carried out to determine the direction of incoming air pollutants or to predict them. Of course, in order to be consistent with the results obtained for pollutants, meteorological data were analyzed for the same time period as for air pollutants.
Conclusions
The analysis of air pollution in terms of seasonality can explicitly confirm the presence of elevated levels in winter months and during the heating season and low in summer months and during the summer season. An exception in this case is ozone whose specific formation in the lowest part of the Earth’s atmosphere causes high concentrations that appear in the periods of maximum insolation, longer days, and higher air temperatures, while low—when activity of the sun is lower, days are shorter, and air temperature is lower (Jeż 2009). Higher levels of air pollution in winter months may also be associated with increased low emissions from local home furnaces, as well as more frequent in these periods, inversion of temperature resulting in smog events. The higher levels of pollution in winter months are represented by PM10 concentrations which exceed the limit values. It was also observed that in winter the levels of such pollutants as sulfur dioxide, nitrogen dioxide, and carbon monoxide were increased but did not exceed the limit values. On the other hand, the reduced levels of such pollutants as nitrogen dioxide and carbon monoxide in summer months can be attributed to the contribution of these compounds to photochemical reactions occurring under the influence of solar radiation which result in the formation of ozone (Jeż 2009).
Considering the seasonal nature of air pollution, we should also refer to the recorded atmospheric conditions from the subsequent months of the analyzed period 2009–2015. It has been observed and confirmed that the values of temperature, humidity, and wind speed for individual months are comparable to those found in the “Atlas of Climate in the Wielkopolska Region” (Farat 2004).
A significant correlation was also found between the elevated levels of air pollutants (PM10, sulfur dioxide, nitrogen dioxide, and carbon monoxide) and low ozone levels in winter months and meteorological parameters such as air temperature (low values), air humidity (high values), and wind speed (high values) in the same time. On the other hand, in summer time, the opposite situation occurred, namely, when temperature was high and wind speed and humidity lower, air pollution was also reduced.
References
- Cichowicz R, Wielgosiński G. Effect of meteorological conditions and building location on CO2 concentration in the university campus. Ecological Chemistry and Engineering S. 2015;22(4):513–525. doi: 10.1515/eces-2015-0030. [DOI] [Google Scholar]
- Cichowicz R, Wielgosiński G. Effect of urban traffic on the immision of carbon dioxide in the university campus. Ecological Chemistry and Engineering S. 2015;22(2):189–200. doi: 10.1515/eces-2015-0010. [DOI] [Google Scholar]
- Colls, J. (2002). Air pollution (2nd edn). London: SPON PRESS, Taylor & Francis Group.
- Farat R. Atlas klimatu województwa wielkopolskiego. Poznań: IMiGW o/Poznań; 2004. [Google Scholar]
- Gurney KR, Razlivanov I, Song Y, Zhou Y, Benes B, Massih MA. Quantification of fossil fuel CO2 emissions on the building/street scale for a large U.S. City. Environmental Science & Technology. 2012;46(21):12194–12202. doi: 10.1021/es3011282. [DOI] [PubMed] [Google Scholar]
- Jeż M. Ochrona atmosfery. Warszawa: Oficyna Wydawnicza Wyższej Szkoły Ekologii i Zarządzania; 2009. [Google Scholar]
- Lelieveld J, Evans JS, Fnais M, Giannadaki D, Pozzer A. The contribution of outdoor air pollution sources to premature mortality on a global scale. Nature. 2015;525:367–371. doi: 10.1038/nature15371. [DOI] [PubMed] [Google Scholar]
- Lin W, Xu X, Ge B, Liu X. Gaseous pollutants in Beijing urban area during the heating period 2007–2008: variability, sources, meteorological, and chemical impacts. Atmospheric Chemistry and Physics. 2011;11:8157–8170. doi: 10.5194/acp-11-8157-2011. [DOI] [Google Scholar]
- Ménard R, Deshaies-Jacques M, Gasset N. A comparison of correlation-length estimation methods for the objective analysis of surface pollutants at Environment and Climate Change Canada. Journal of the Air & Waste Management Association. 2016;66:9,874–9,895. doi: 10.1080/10962247.2016.1177620. [DOI] [PubMed] [Google Scholar]
- Nemitz E, Hargreaves KJ, McDonald AG, Dorsey JR, Fowler D. Micrometeorological measurements of the urban heat budget and CO2 emissions on a city scale. Environmental Science & Technology. 2002;36(14):3139–3146. doi: 10.1021/es010277e. [DOI] [PubMed] [Google Scholar]
- Vallero, D. (2014). Fundamentals of air pollution (5th edn). London: Elsevier Inc. Academic Press.