Skip to main content
Journal of Analytical Methods in Chemistry logoLink to Journal of Analytical Methods in Chemistry
. 2017 Oct 24;2017:9194847. doi: 10.1155/2017/9194847

Simultaneous Determination of Six Active Components in Oviductus Ranae via Quantitative Analysis of Multicomponents by Single Marker

Shihan Wang 1, Yang Xu 2, Yanwei Wang 1, Huailei Yang 3, Zuying Lv 1, Xiangqun Jin 1,, Yongsheng Wang 1,
PMCID: PMC5672127  PMID: 29201491

Abstract

A method, quantitative analysis of multicomponents by single marker (QAMS), was established in this article to investigate the quality control of a traditional Chinese medicine, Oviductus Ranae. 7-Hydroxycholesterol, 7-ketocholesterol, 4-cholesten-3-one, stigmasterol, 7-dehydrocholesterol, and cholesterol were selected as the indexes of quality evaluation of Oviductus Rana. The determination was achieved on an Agilent HC-C18 column (4.6 mm × 250 mm, 5 μm) using methanol with water (87 : 13 v/v) as mobile phase at the flow rate of 2.0 mL/min. Cholesterol was used as an internal standard to determine the relative correction factors between cholesterol and other steroidal constituents in Oviductus Ranae. The contents of those steroidal constituents were calculated at the same time. To evaluate the QAMS method, an external standard method was used to determine the contents of six steroidal constituents. No significant difference was observed when comparing the quantitative results of QAMS with the results of external standard method. The proposed QAMS method was proved to be accurate and feasible based on methodological experiments. QAMS provided a simple, efficient, economical, and accurate way to control the quality of Oviductus Ranae.

1. Introduction

Oviductus Ranae, a traditional Chinese medicine (TCM), can be obtained from dry oviduct of female Rana temporaria chensinensis David [1]. It has increasingly attracted worldwide attention because of its effect on nourishing Yin and moistening lung, strengthening the spleen and stomach, nourishing the kidney, and strengthening the essence as well. Pharmacology study showed it also has curative effects such as antitussive, antiasthmatic, antiaging, and antifatigue effects and enhancing the efficacy of immunity [25]. The challenge preventing its clinical practice is the uncontrollable quality of Oviductus Ranae. Determination method for the components of Oviductus Ranae has not been introduced in Chinese Pharmacopoeia (Chp; 2015 edition). Current method for the quality control of Oviductus Ranae involves using single component or a marker compound as the internal standard substance [68]. However, high-quality standard compounds or references are quite expensive and relying on single component of quality control is insufficient. Therefore, establishing a low-cost, reliable, and efficient approach is significantly important.

Quantitative analysis of multicomponents by single marker (QAMS) has been regarded as an alternative to the quality control of TCMs [915]. The relative correction factor (RCF) of contents in Oviductus Ranae is calculated using the reference substance of each analyte [1618]. The RCF of the other six analytes were determined. Their contents were calculated based on RCF. Steroidal constituents in Oviductus Ranae have significant pharmacological activities which are mainly exhibited on the aspects of antifatigue, immunity enhancement, antiaging, maintaining the balance of hormones. In addition, some steroids can be transformed into other steroid hormones with good activities through biological transformation [1933]. To develop a QAMS method for the simultaneous determination of six active components in Oviductus Ranae, cholesterol was chosen as the internal standard substance. Six active steroidal components were selected as the indexes of quality evaluation of Oviductus Ranae (Figure 1).

Figure 1.

Figure 1

The chemical structures of six analytes: 7-hydroxycholesterol (1), 7-ketocholesterol (2), 4-cholesten-3-one (3), stigmasterol (4), 7-dehydrocholesterol (5), and cholesterol (6).

2. Experimental

2.1. Instrument and Chromatographic Conditions

Chromatographic separation was achieved on Agilent 1260 high performance liquid chromatography (HPLC) equipped with DAD detector (G1315B), automatic sampling device (G1329B), Agilent Chemstation workstation, and Waters Alliance E2695. Another high performance liquid chromatography was equipped with 2489 UV detector, automatic sampling device (E2695), and Empower workstation. Agilent HC-C18, Amethyst C18-P, and Eclipse XDB-C18 (250 mm × 4.6 mm, 5 μm) were employed during the experiment under the following chromatographic conditions: the mobile phase was composed of methanol and water (87 : 13 v/v) under the detection wavelength of 205 nm, 240 nm, and 280 nm at the flow rate of 2.0 mL·min−1. The column temperature was maintained at 35°C, and the injection volume was 10 μL. KQ-400KDB high power digital ultrasonic cleaner was purchased from Kunshan Ultrasonic Instrument Co. Ltd. RE-52-99 rotary evaporator was purchased from Shanghai Ya Rong Biochemical Instrument Factory. WP-UP-III-10 ultrapure water was purchased from Sichuan Water Treatment Equipment Co. Ltd.

2.2. Reagents and Materials

Cholesterol (batch number: 111618-200301) was purchased from China Food and Drug Verification Research Institute (Beijing, China). 4-Cholesten-3-one (batch number: S45539-479) was purchased from American sigma company (USA). 7-Dehydrogenation cholesterol (batch number: CDCT-12115000) was purchsed from Dr. Ehrenstorfer (Germany). Stigmasterol (batch number: A0510) was purchased from Shanghai Yao Yun Biological Science and Technology Co., Ltd. 7-Ketocholesterol and 7-hydroxycholesterol were prepared by laboratory according to previous reports (content: more than or equal to 98%) [34]. Fourteen batches of Oviductus Ranae were collected from different regions in China, which were conducted by Professor Dacheng Jiang from Changchun University of Traditional Chinese Medicine and proved to be dry oviduct of female Rana temporaria chensinensis David. The details were showed in Table 1. Methanol (Fisher, America) was of chromatographic grade, and other reagents (Beijing Chemical Industry Factory) were of analytical grade. Ultrapure water was prepared by water instrument WP-UP-III-10.

Table 1.

Batch and origin of Oviductus Ranae.

NO. Origin Year Batch
S1 Tonghua, Jilin Province 2014 201401
S2 Tonghua, Jilin Province 2014 201402
S3 Huadian, Jilin Province 2015 201503
S4 Huadian, Jilin Province 2015 201504
S5 Heihe, Heilongjiang Province 2015 201505
S6 Dunhua, Jilin Province 2015 201506
S7 Jingyu, Jilin Province 2015 201507
S8 Jingyu, Jilin Province 2015 201508
S9 Fangzheng, Heilongjiang Province 2015 201509
S10 Mudanjiang, Heilongjiang Province 2015 201510
S11 Antu, Jilin Province 2015 201511
S12 Dandong, Liaoning Province 2015 201512
S13 Hebei Province 2015 201513
S14 Hulin, Heilongjiang Province 2015 201514

2.3. Preparation of Mixed Standard Solution

Substances of 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, cholesterol, and stigmasterol were weighed precisely and dissolved into methanol to prepare standard solutions with the concentration of 1.579 × 102μg/mL, 32.525 μg/mL, 20.225 μg/mL, 9.775 μg/mL, 4.00 × 103μg/mL, and 25.738 μg/mL, respectively. The standard solutions were stored at 4°C in refrigerator.

2.4. Preparation of Test Solutions

About 2.0 g Oviductus Ranae powder (40-mesh sieve) was accurately weighed and placed in a Erlenmeyer flask. 40 mL dichloromethane was added to the flask and extracted for 20 min via ultrasonic method with the power of 400 W and the frequency of 40 KHz. The extraction was repeated for three times and filtered. The combined filtrates were concentrated via roller evaporator. The residue was dissolved into 2 mL of methanol in volumetric flask. The solution was then filtrated through a 0.22 μm membrane. The filtrate was regarded as the test solution.

2.5. Method Validation

2.5.1. System Adaptability Test

Blank solvent, standard solution, and sample solution of each substance were analyzed based on the chromatographic condition of Section 2.1 and the results showed in Figures 2, 3, and 4.

Figure 2.

Figure 2

Blank solvent of three detection wavelengths including (a) 205 nm, (b) 240 nm, and (c) 280 nm.

Figure 3.

Figure 3

The chromatograms of mixed reference substance ((1) 7-hydroxycholesterol; (2) 7-ketocholesterol; (3) cholest-4-en-3-one; (4) 7-dehydrocholesterol; (5) cholesterol; (6) stigmasterol) at three detection wavelengths ((a) 205 nm; (b) 240 nm; (c) 280 nm).

Figure 4.

Figure 4

The chromatograms of test samples ((1) 7-hydroxycholesterol; (2) 7-ketocholesterol; (3) cholest-4-en-3-one; (4) 7-dehydrocholesterol; (5) cholesterol; (6) stigmasterol) at three detection wavelengths ((a) 205 nm; (b) 240 nm; (c) 280 nm).

2.5.2. Liner Range

A series volume of mixed standard solutions was transferred by volume with 5 μL, 10 μL, 15 μL, 20 μL, 30 μL, 40 μL, 50 μL, and 60 μL and injected into HPLC, respectively. Chromatogram was recorded and the standard curve was drawn with peak area (Y) as the vertical coordinate and the content of the measured substance (X) as horizontal coordinate. The mixed control solutions were diluted with methanol. The limits of detection (LOD) and the limits of quantification (LOQ) were determined by three times and ten times of the signal noise ratio, respectively.

2.5.3. Precision

An intraday precision test was carried out by the following method. The same mixed control solution was transferred in the same day for six times in a row. RSD% was calculated according to the chromatographic peak area of the components.

2.5.4. Stability Test

The sample solution was injected into HPLC at 0, 2, 4, 6, 8, 10, 12, and 24 h after being prepared and peak area of each component was recorded and RSD% was calculated.

2.5.5. Repeatability Test

The same batch of Oviductus Ranae drug powder was transferred to prepare six sample solutions in parallel according to method of Section 2.4. The chromatographic peak area of each component was recorded. The content and RSD% were calculated.

2.5.6. Recovery Test

About 1.0 g of the same batch of Oviductus Ranae powder was weighed precisely, and then a certain amount of control sample solution was added to the sample according to the proportion of sample content-reference substance (1 : 1) to prepare six sample solutions in parallel referring to method of Section 2.3. The six sample solutions were injected into HPLC, respectively, and the peak areas were recorded to calculate average recovery rate and RSD% of each sample.

2.5.7. Durability Test

The durability test was conducted by two different instruments which were Agilent 1260 and Waters E2695. Three different chromatographic columns were applied including Agilent HC-C18, Eclipse XDB-C18, and Amethyst C18-P (250 mm × 4.6 mm, 5 μm). Analysis was determined at the flow rate of 2.2 mL·min−1, 2.0 mL·min−1, and 1.8 mL·min−1 with the column temperature of 30°C, 35°C, and 40°C. The content and RSD% of the six steroid components in the same batch were calculated. The separation degree of the charmatographic column was investigated. The number of theoretical plates was also investigated

3. Results and Discussion

3.1. Method Validation

3.1.1. System Adaptability Test

The theoretical plates were selected according to the separation resolution between the analytes and impurities. After several tests of standards and testing samples, we found when theoretical plates are bigger than or equal to 3500 the analytes have good resolution in chromatographic peaks. The results of system adaptability are showed in Figures 2, 3, and 4. The resolutions of 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, cholesterol, and stigmasterol were more than 1.5 and the number of theoretical plates was greater than 3500.

3.1.2. Liner Range

The results were showed in Table 2. High coefficient of determination values (R2 > 0.9997) showed good linearity. LOD and LOQ of six substances were within the range of 0.055–0.100 μg/mL and 2.445–1.001 × 103μg/mL, which showed a high sensitivity under the established chromatographic condition.

Table 2.

The linear equations, coefficient of determination, and linear range of six components.

Substance Liner equation R 2 Liner range/μg/mL LOD/μg/mL LOQ/μg/mL
Cholesterol y = 206.39x − 1.93 1.0000 1.00 × 103–1.20 × 103 0.075 1.001 × 103
Stigmasterol y = 1704.6x + 16.13 0.9997 6.43–77.21 0.085 6.435
7-Hydrocholesteol y = 316.9x + 3.13 0.9998 39.47–473.70 0.060 39.475
7-Ketocholesterol y = 1094.3x − 0.33 1.0000 8.13–97.57 0.065 8.130
4-Cholesten-3-one y = 1120.8x + 1.10 1.0000 5.05–60.67 0.055 5.055
7-Dehydrogenation cholesterol y = 620.05x − 0.42 0.9999 2.44–29.32 0.100 2.445

3.1.3. Precision

The results showed that RSD% values of the peak area of 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, cholesterol, and stigmasterol were 0.5%, 0.8%, 0.8%, 1.1%, 0.3%, and 0.5%, which showed a good instrument precision.

3.1.4. Stability Test

The results showed that RSD% values of the peak area of 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, cholesterol, and stigmasterol were 0.9%, 0.7%, 1.1%, 1.0%, 0.1%, and 0.4% (RSD% ≤ 2.0%), indicating that the tested sample solution was stable within 24 h.

3.1.5. Repeatability Test

The results revealed that average mass fraction and RSD% values of the peak area of 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, cholesterol, and stigmasterol were 74.30 μg/mL, 17.70 μg/mL, 7.29 μg/mL, 5.17 μg/mL, 3.48 μg/mL, and 15.13 μg/mL and 0.6%, 0.4%, 0.5%, 0.9%, 1.0%, and 0.8%. The method had good repeatability.

3.1.6. Recovery Test

The results showed that average recovery rate and RSD% of the peak area of 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, cholesterol, and stigmasterol were 98.0%, 98.1%, 99.1% 99.2%, 98.3%, 98.9%, and 1.3%, 1.5%, 1.6%, 1.0%, 0.9%, and 1.5%, illustrating that the method was of good accuracy.

3.1.7. Durability Test

The RSD% results of mass fractions, determined in all the above conditions, were less than 3.1%, which showed separation effect was good. According to the tests, the determination conditions of six steroidal components in Oviductus Ranae were wide and the method exhibited good durability.

3.2. Quantitative Analysis of Multicomponents by Single Marker

3.2.1. Calculation of Relative Correction Factor

In standard curve Y = a × X + b, X = (Yb)/a = Y/ab/a, and value of b/a can be ignored when the value of a/b is greater than 100 because the value of b is usually caused by error. At this point, the formula can be directly calculated as X = Y/a. Therefore, the relative correction factor can be calculated by the ratio of the slope (a). The relative correction factor calculation formula is shown as follows:

fK/S=aKaS, (1)

where aS is the slope of reference and aK is the slope of the other component to be measured [33]. Cholesterol was selected as an internal reference (1.000) for the quantitative analysis of other five steroids, including 7-hydrocholesteol, 7-ketocholesterol, 4-cholesten-3-one, 7-dehydrogenation cholesterol, and stigmasterol with the detection wavelengths of 205 nm, 240 nm, and 280 nm, respectively. The relative correction factors of 7-hydrocholesteol and stigmasterol were 1.5354 and 8.2591 under 205 nm. The relative correction factors of 7-ketocholesterol and 4-cholesten-3-one were 5.3021 and 5.4305 under 240 nm. The relative correction factor of 7-dehydrogenation cholesterol was 3.0043.

3.2.2. Reproducibility of RCF

In this paper, the effects of two sets of chromatographic systems (Agilent 1260 and Waters E2695), three kinds of chromatographic columns (Agilent HC-C18, Eclipse XDB-C18, and Amethyst C18-P (250 mm × 4.6 mm, 5 μm), and different column temperatures and different flow rates on RCF were investigated. Results showed RSDs measured in different conditions were all less than 1.19%. The experiments were repeated by different researchers in different laboratories with the same conditions, and all results showed RSDs were less than 2.0%. indicating the RCF calculated by the established method has good reproducibility.

3.2.3. Location of Chromatographic Peak of the Measured Component

The relative retention time was achieved based on the ratio of retention time of measured component (k) and internal standard (s). The formula was shown as follows:

RtR=tRktRs, (2)

where k is the component to be measured and s is regarded as internal reference cholesterol. The relative retention time between internal reference cholesterol and other components was calculated through formula (2). The effects of different chromatographic systems, column temperatures, and flow rates on RSDs of relative retention time were evaluated. Results showed RSDs of relative retention time between tested components and internal standard cholesterol were less than 0.67% and the RSD% results of durability study were also less than 4.91%. On the other hand, each tested component was scanned via the diode array detector (DAD). 3D absorption spectrum of each compound was obtained, showed in Figure 5. Peak time of each component can be predicted through the relative retention time, but if other peaks existed near the chromatographic peaks, chromatographic peaks can also be located by overall shape or 3D absorption spectra. Therefore, chromatographic peak can be accurately located in a certain extent by the method established above.

Figure 5.

Figure 5

(a) Cholest-4-en-3-one, (b) stigmasterol, (c) cholesterol, (e) 7-hydroxycholesterol, and (f) 7-ketocholesterol. 3D absorption spectroscopy of each component.

3.2.4. Comparison of the Results of QAMS Method and External Standard Method

Fourteen batches of Oviductus Ranae powder purchased from different regions were prepared based on the method of Section 2.4. Samples obtained from each region were prepared for two independent copies in parallel and injected into HPLC based on the method of Section 2.1. Subsequently, chromatographic peak area of each tested component was recorded. Then, the content of each component was calculated by the method of ES and QAMS, respectively. Results were shown in Table 3. There were no significant differences between the results of two methods. In addition, the relative errors were less than 2%, which indicated that the method established above was accurate and reliable.

Table 3.

Determination results and comparison of different method of six steroid components in Oviductus Ranae.

NO. Method Cholesterol 7-hydroxycholesterol 7-ketocholesterol Cholest-4-en-3-one Stigamasterol 7-dehydroxycholesterol
μg·g−1 μg·g−1 RSD% μg·g−1 RSD% μg·g−1 RSD% μg·g−1 RSD% μg·g−1 RSD%
(1) ES 3.5 × 103 75.1 0.1 17.6 −0.6 7.3 0.4 15.1 0.3 5.2 −0.8
QAMS 75.2 17.5 7.3 15.1 5.1
(2) ES 3.8 × 103 77.9 −0.1 19.4 −0.6 8.4 −0.4 15.4 0.3 5.5 0.7
QAMS 77.8 19.3 8.4 15.5 5.5
(3) ES 2.3 × 103 59.5 −0.1 13.1 0.6 6.6 −0.5 11.2 0.4 4.1 1.0
QAMS 59.4 13.1 6.5 11.3 4.1
(4) ES 3.5 × 103 70.2 0.1 16.9 0.7 7.4 0.7 14.9 −0.4 5.2 0.8
QAMS 70.3 17.0 7.5 14.9 5.3
(5) ES 3.2 × 103 66.1 −0.1 16.0 0.6 7.4 0.4 14.8 0.3 4.8 −0.8
QAMS 66.0 16.1 7.4 14.8 4.7
(6) ES 3.0 × 103 64.8 0.1 15.5 −0.6 7.1 0.4 14.6 0.3 4.2 1.0
QAMS 64.8 15.4 7.1 14.6 4.3
(7) ES 3.1 × 103 67.7 −0.2 15.9 −0.8 7.3 0.7 14.7 −0.3 4.5 0.9
QAMS 67.6 15.8 7.3 14.6 4.6
(8) ES 3.2 × 103 60.7 0.2 14.5 −0.8 6.9 0.4 14.4 0.4 4.9 −0.8
QAMS 60.8 14.3 6.9 14.5 4.8
(9) ES 3.9 × 103 81.2 0.1 22.1 0.6 9.2 0.6 15.6 −0.4 6.1 0.8
QAMS 81.3 22.2 9.2 15.6 6.1
(10) ES 2.5 × 103 60.1 −0.1 13.4 0.8 6.7 −0.6 12.7 −0.4 4.1 1.0
QAMS 60.0 13.5 6.6 12.7 4.2
(11) ES 3.3 × 103 72.4 −0.12 17.8 −0.8 7.3 −0.4 14.1 −0.4 4.6 0.9
QAMS 72.3 17.7 7.3 14.1 4.7
(12) ES 3.6 × 103 70.6 −0.1 18.4 0.7 7.6 0.5 14.3 0.3 5.2 0.8
QAMS 70.5 18.5 7.7 14.3 5.3
(13) ES 3.9 × 103 78.9 −0.1 21.2 0.7 8.7 −0.3 15.3 0.3 5.9 0.9
QAMS 78.8 21.4 8.7 15.4 5.9
(14) ES 2.7 × 103 61.5 0.1 12.3 −0.7 6.3 0.6 13.2 0.4 4.0 0.8
QAMS 61.6 12.2 6.3 13.2 4.0
(15) ES 2.1 × 103 53.4 −0.1 11.6 0.9 5.8 −0.5 11.8 0.3 3.7 1.1
QAMS 53.3 11.7 5.8 11.8 3.8
(16) ES 2.7 × 103 60.1 0.2 12.8 0.8 6.7 0.6 13.6 0.4 4.8 0.8
QAMS 60.2 12.9 6.7 13.6 4.9

3.3. Discussion

Cholesterol was selected as the internal reference substance of QAMS method, because cholesterol is one of the main components of Oviductus Ranae with high amount, low price, and easy acquisition. Furthermore, there were no significant differences between the content determination results of QAMS method and ES method when cholesterol was regarded as internal reference material, and the relative error was less than 2% as well.

In this paper, to obtain a good separation degree, higher theoretical plate number, and good symmetry of chromatographic peak, different mobile phase conditions were investigated for system adaptability test. It was found that the chromatographic peak of all the tested components could achieve baseline separation with the adjacent peaks using methanol and water (87 : 13 v/v) as mobile phase. To confirm the best preparation method of the tested sample solution, different extraction solvent (methanol, dichloromethane, and chloroform), extraction method (cold soak, ultrasonic, and reflux), amount of the solvent (30 mL, 40 mL, and 50 mL), and extraction time (10 min, 20 min, and 30 min) were studied. The best preparation process was considered as extracting with 40 mL dichloromethane for 20 min via ultrasonic method based on the single factor investigation experiment mentioned above.

It was critical to select suitable detection wavelength for achieving a good separation. The selection of detection wavelength relied on the UV absorption characteristics of the internal reference material and the separation of other components in the test samples. Internal reference cholesterol, 7-hydroxycholesterol, and stigmasterol all exhibited good UV absorption and good separating degree at 205 nm. The wavelength of 205 nm was regarded as one of the detection wavelengths for the reason above. However, detection of cholest-4-en-3-one and 7-dehydrocholesterol was not sensitive at 205 nm because of less content in Oviductus Ranae. Thus, based on the characteristics of UV absorption of these two substances, 240 nm and 280 nm were selected as the detection wavelengths, respectively. The detection wavelength of cholesterol, 7-hydroxycholesterol, and stigmasterol was 205 nm. The detection wavelength of cholest-4-en-3-one and 7-ketocholesterol was determined as 240 nm, and 7-dehydrocholesterol was detected at 280 nm.

In this experiment, two kinds of method were investigated including the difference of retention time and relative retention time for locating chromatographic peaks when using cholesterol as internal reference substance. Compared with the results of retention time difference method, the relative retention time was relatively stable, and the RSD% was less than 4.9%. Thus, the chromatographic peak position can be located according to the relative retention time of chromatographic peaks between tested compounds and internal standard cholesterol, the chromatograms of the overall shape, and the 3D absorption spectra information of six components in Oviductus Ranae.

4. Conclusion

In this paper, HPLC-DAD method was adopted for determination of relative retention time and relative correction factor of six steroids in Oviductus Ranae for the first time. A QAMS method was developed for determining the contents of six kinds of steroidal constituents simultaneously. The QAMS method established in this study has been proved by method validation methodology to be accurate, feasible, and reliable for determination of contents of six steroidal components and can be applied to the quality control of Oviductus Ranae.

Acknowledgments

Thanks are due to Jilin University for providing the research offices.

Contributor Information

Xiangqun Jin, Email: jinxq@jlu.edu.cn.

Yongsheng Wang, Email: 165690808@qq.com.

Ethical Approval

This article does not contain any studies with human participants or animal performed by any of the authors.

Conflicts of Interest

All authors declare that they have no conflicts of interest.

References

  • 1.National Pharmacopoeia Committee. The pharmacopoeia of the People's Republic of China. Vol. 255. Beijing: China: China Medical Science And Technology Press; 2015. [Google Scholar]
  • 2.Zhang P., Yang J. Y. The influence of oviductus ranae on glucose metabolism in mice in sports training. Journal of Hygiene Research. 2014;43(1):124–127. [Google Scholar]
  • 3.Lou C. S., Cao J. M. Effect of oviductus ranae on testosterone content, substance metabolism and exercise capacity in rats receiving exercise training. Chinese Journal of Experimental Traditional Medical Formula. 2014;20(20):150–154. [Google Scholar]
  • 4.Cao L. The pharmacological research progress of oviductus ranae is outlined. HeiLongJiang Medical Journal. 2002;15(5):p. 384. [Google Scholar]
  • 5.Xiao J. L., Liu C. Y. Research progress of pharmacological effects on rare animal medicine oviductus ranae. Jilin Journal of Traditional Chinese Medicine. 2012;32(7):751–753. [Google Scholar]
  • 6.Wang Y. S., Cao Y. H. Studies on determination of contents of cholesterol in oviductus ranae. Chinese Traditional Patent. 2008;30(9):1402–1404. [Google Scholar]
  • 7.Wang Y. S. The Study on Drug Efficacy Ingredients of Oviductus Ranae and Its Quality Contro Method. Changchun, China: Jilin University; 2007. [Google Scholar]
  • 8.Liu J., Liu S., Liu C. C. Determination of estradiol in oviductus ranae by HPLC. Liaoning Journal of Traditional Chinese Medicine. 2009;37(1):138–139. [Google Scholar]
  • 9.Yan C., Wu Y., Weng Z., et al. Development of an HPLC Method for Absolute Quantification and QAMS of Flavonoids Components in Psoralea corylifolia L. Journal of Analytical Methods in Chemistry. 2015;2015:7. doi: 10.1155/2015/792637.792637 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Gao H. M., Wang Z. M., Li Y. J., Qian Z. Z. Overview of the quality standard research of traditional Chinese. Frontiers of Medicine. 2011;5(2):195–202. doi: 10.1007/s11684-011-0134-x. [DOI] [PubMed] [Google Scholar]
  • 11.Song X.-Y., Li Y.-D., Shi Y.-P., Jin L., Chen J. Quality control of traditional Chinese medicines: a review. Chinese Journal of Natural Medicines. 2013;11(6):596–607. doi: 10.1016/S1875-5364(13)60069-2. [DOI] [PubMed] [Google Scholar]
  • 12.Chen A., Sun L., Yuan H., Wu A., Lu J., Ma S. A holistic strategy for quality and safety control of traditional Chinese medicines by the “iVarious” standard system. Journal of Pharmaceutical Analysis. 2017 doi: 10.1016/j.jpha.2017.07.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Wang C.-Q., Jia X.-H., Zhu S., Komatsu K., Wang X., Cai S.-Q. A systematic study on the influencing parameters and improvement of quantitative analysis of multi-component with single marker method using notoginseng as research subject. Talanta. 2015;134:587–595. doi: 10.1016/j.talanta.2014.11.028. [DOI] [PubMed] [Google Scholar]
  • 14.Li D.-W., Zhu M., Shao Y.-D., Shen Z., Weng C.-C., Yan W.-D. Determination and quality evaluation of green tea extracts through qualitative and quantitative analysis of multi-components by single marker (QAMS) Food Chemistry. 2016;197:1112–1120. doi: 10.1016/j.foodchem.2015.11.101. [DOI] [PubMed] [Google Scholar]
  • 15.Wang L.-L., Zhang Y.-B., Sun X.-Y., Chen S.-Q. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker. Journal of Liquid Chromatography and Related Technologies. 2016;39(8):422–427. doi: 10.1080/10826076.2016.1169429. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Kuang G., Zhou J., Yao M., et al. Systematic study on QAMS method for simultaneous determination of triterpenoid saponins in Ilex pubescens by HPLC and UPLC. Analytical Methods. 2015;7(16):6579–6587. doi: 10.1039/c5ay01274k. [DOI] [Google Scholar]
  • 17.Yan L., Wei X., Ji T., et al. Development of a novel method combining multi-wavelength HPLC fingerprint and quantitative analysis of multi-component by single marker for quality control of Houttuynia cordata. Journal of Chemical and Pharmaceutical Research. 2014;6(8):347–356. [Google Scholar]
  • 18.Zhu C., Li X., Zhang B., Lin Z. Quantitative analysis of multi-components by single marker—a rational method for the internal quality of Chinese herbal medicine. Integrative Medicine Research. 2017;6(1):1–11. doi: 10.1016/j.imr.2017.01.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Wang B., Shi H. S., Song L. The Physiological Functions of Cholesterol and the Treatment of Hyperlipidemia and Atherosclerosis. China Practical Medicine. 2007;2(25):53–54. [Google Scholar]
  • 20.Zhang L. Preparation Method for 7-dehydroxycholesterol. Beijing, China: Beijing University of Chemical Technology; 2008. [Google Scholar]
  • 21.Wang Y. Q., Xv W. L. Studies on the recrystallization purification and separation of stigamasterol from phytosterols. Journal of Yangzhou University. 2002;5(2):53–56. [Google Scholar]
  • 22.Yoshida Y., Niki E. Antioxidant effects of phytosterol and its components. Journal of Nutritional Science and Vitaminology. 2003;49(4):277–280. doi: 10.3177/jnsv.49.277. [DOI] [PubMed] [Google Scholar]
  • 23.Zhang S., Yue W. Inhibitive effect of Stigmasterol from Hedyotis diffusa willd. On hepatoma cells in vitro and vivo and its influence on transplanted H22 tumor cell’s multiplication cycle, apoptosis. Progress in Modern Blomedicine. 2008;8(11):2016–2017. [Google Scholar]
  • 24.Chen W., Yu C., Hu P., Bao J., Tang J., Wu L. Stigmasterol blocks cartilage degradation in rabbit model of osteoarthritis. Acta Biochimica Polonica. 2012;59(4):537–541. [PubMed] [Google Scholar]
  • 25.Batta A. K., Xu G., Honda A., Miyazaki T., Salen G. Stigmasterol reduces plasma cholesterol levels and inhibits hepatic synthesis and intestinal absorption in the rat. Metabolism: Clinical and Experimental. 2006;55(3):292–299. doi: 10.1016/j.metabol.2005.08.024. [DOI] [PubMed] [Google Scholar]
  • 26.Suzuki K. Formation of cholest-4-en-3-one by intestinal bacteria and its biological effect. RIKEN Review. Focused on Microbial Diversity. 1993;3:17–18. [Google Scholar]
  • 27.Barton D. H. The invention of chemical reactions: the last five years. ChemInform. 1992;23(29):p. 303. [Google Scholar]
  • 28.Wu K., Li W., Song J., Li T. Production, purification, and identification of cholest-4-en-3-one produced by cholesterol oxidase from rhodococcus sp. in aqueous/organic biphasic system. Biochemistry Insights. 2015;8(1):1–8. doi: 10.4137/BCI.S21580. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Lv C. F., Chen Y. L. Bioconversion of cholesterol by cholesterol oxidase from Brevibacterium sp. Journal of Wuxi University of Light Industry. 2001;20(5):485–488. [Google Scholar]
  • 30.Wakefield A. E., Ho S.-Y., Li X.-G., D'Arrigo J. S., Simon R. H. The use of lipid-coated microbubbles as a delivery agent of 7β-hydroxycholesterol in a radiofrequency lesion in the rat brain. Neurosurgery. 1998;42(3):592–598. doi: 10.1097/00006123-199803000-00029. [DOI] [PubMed] [Google Scholar]
  • 31.Cao X. B., Sun S. G. Effect of 7β-hydroxycholesterol on glutamate transporters expression and its mechanism in hippocampus in rats of post traumatic epilepsy. Chinese Journal of Rehabilitation. 2005;20(2):333–336. [Google Scholar]
  • 32.Saito Y., Noguchi N. 7-Hydroxycholestrol as a possible biomarker of cellular lipid peroxidation: difference between cellular and plasma lipid peroxidation. Biochemical and Biophysical Research Communications. 2014;446(3):741–744. doi: 10.1016/j.bbrc.2013.12.083. [DOI] [PubMed] [Google Scholar]
  • 33.He B., Liu Y. Simultaneous determination of 10 constituents in Shuangqing Yanhou Tablets by HPLC-QAMS. Chinese Traditional and Herbal Drugs. 2013;44(8):974–981. [Google Scholar]
  • 34.Zhao X. Studies on Synthesis of 7-Ketocholesterol and 7β-Hydroxycholesterol. Changchun, China: Jilin University; 2010. [Google Scholar]

Articles from Journal of Analytical Methods in Chemistry are provided here courtesy of Wiley

RESOURCES