Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2018 Jul 1.
Published in final edited form as: J Manipulative Physiol Ther. 2017 Jun 17;40(6):371–380. doi: 10.1016/j.jmpt.2017.03.006

Characteristics of Paraspinal Muscle Spindle Response to Mechanically-Assisted Spinal Manipulation-A Preliminary Report

William R Reed 1, Joel G Pickar 2, Randall S Sozio 3, Michael AK Liebschner 4, Joshua W Little 5, Maruti R Gudavalli 6
PMCID: PMC5679286  NIHMSID: NIHMS873924  PMID: 28633885

Abstract

Objectives

The purpose of this preliminary study is to determine muscle spindle response characteristics related to the use of two solenoid powered clinical mechanically-assisted manipulation (MAM) devices.

Methods

L6 muscle spindle afferents with receptive fields in paraspinal muscles were isolated in 6 cats. Neural recordings were made during L7 MAM thrusts using the Activator V and/or Pulstar devices at their 3 lowest force settings. MAM response measures included: a) the time required post-thrust until the 1st action potential, b) differences in mean frequency (MF) and mean instantaneous frequency (MIF) 2s before and after MAM, and c) the time required for muscle spindle discharge (MF & MIF) to return to 95% of baseline following MAM.

Results

Depending on device setting, between 44–80% (Pulstar) and 11–63% (Activator V) of spindle afferents required >6s to return to within 95% of baseline MF values; whereas 66–89% (Pulstar) and 75–100% (Activator V) of spindle responses returned to within 95% of baseline MIF in <6s following MAM. Nonparametric comparisons between the 22 and 44N settings of the Pulstar yielded significant differences for the time required to return to baseline MF and MIF.

Conclusion

Short duration (<10ms) MAM thrusts decrease muscle spindle discharge with a majority of afferents requiring prolonged periods of time (>6s) to return to baseline MF activity. Physiological consequences and/or clinical relevance of described MAM mechanoreceptor responses will require additional investigation.

Keywords: Spinal manipulation, muscle spindles, afferent neurons, spine

Introduction

Low back pain (LBP) continues to be a major societal health problem and prevalence rates are only expected to increase with the aging of the American population.1,2 More than 80% of the population will experience an episode of LBP during their lives, with 20 to 40% experiencing a reoccurrence of a LBP episode within 1 year after the initial onset in working populations.3,4 LBP can be treated with multiple approaches including non-pharmacological, pharmacological, and surgical interventions. The efficacy, favorable side-effect profile, cost-effectiveness and high patient satisfaction associated with the non-pharmacological approach of spinal manipulation have led to multiple clinical practice guidelines and evidence reports recommending spinal manipulation for certain types of acute and chronic LBP.511 However, the appropriate use and clinical efficacy of spinal manipulation could be greatly enhanced if underlying peripheral and central neurophysiological mechanisms were clearly established. Accomplishing these objectives will require combined contributions from both basic and clinical investigations.

Spinal manipulation traditionally involves applying a single, short lever, high velocity low amplitude (HVLA) thrust of short duration to a targeted dysfunctional vertebral motion segment and/or joint. HVLA thrusts can be delivered manually with direct hand contact (≤150ms thrust duration) or using commercially available mechanical-assisted devices (≤10ms thrust duration).1218 Peak forces achieved during a manipulative thrust can vary dramatically depending upon anatomical location of treatment, localized tissue compliance, clinician and/or patient’s physical traits, spinal manipulative technique, mechanical-assisted device used and/or device setting.1525 A distinct advantage mechanically-assisted manipulation (MAM) offers over manual spinal manipulation is that thrust velocity and thrust magnitude can be standardized. MAM is thought to be an effective alternative to manual thrust manipulation based upon both comparable measures of vertebrae movements12,2630 and similar clinical outcomes reported in a few smaller studies.3134 A recent randomized clinical trial comparing manually-delivered spinal manipulation and MAM indicated differences in short-term clinical efficacy,35 thereby suggesting that distinct physiological mechanisms of action might be responsible for the underlying therapeutic effects of these two types of HVLA spinal manipulation.

Proposed physiological mechanisms of action by which spinal manipulation of any type ameliorates musculoskeletal pain include stretch reflex inhibition generated by stretch-induced stimulation of mechanoreceptors or nociceptors in the facet joint capsule and/or the surrounding spinal tissues (muscles, ligaments, discs).3643 In humans, the Hoffmann reflex (H-reflex) and stretch reflexes have been used to provide a neurophysiological index of α-motoneuron excitability. A commonality shared by a majority of spinal manipulative studies that investigated H-reflex and stretch reflex responses is the concept that manual therapies mechanistically act by reflexively reducing central α-motoneuron activity via modulating the sensitivity of muscle spindle afferents to muscle stretch.37,4148 Using a computer-controlled feedback motor, we have previously investigated the relationship between various biomechanical parameters of spinal manipulation (thrust duration, thrust magnitude, thrust rate, thrust contact site etc.) and paraspinal muscle spindle responsiveness in both laminectomy-only and acute facet joint fixation animal models.4955 Time to peak impulse in the majority of these animal studies ranged from 75–150ms which is more closely aligned with manually-delivered spinal manipulation compared to the faster time to peak impulse of 2–7ms reported among MAM devices.15,18 This extremely short time to peak impulse with MAM devices may result in unique muscle spindle responses and/or central reflex-related mechanisms as these particular mechanoreceptors are sensitive to the rate of muscle stretch.

To begin to address the neurophysiological impact of these extremely short MAM thrust durations, we recently conducted a pilot study in a single feline preparation to determine the feasibility of recording muscle spindle afferent responses using an instrumented spring-loaded hammer MAM device (Activator IV ; Activator Methods Int. Ltd., Phoenix, AZ).56 Despite recording from a limited number of muscle spindle afferents, this pilot study clearly demonstrated that a diverse set of muscle spindle afferent responses are elicited using clinical MAM devices. Post-thrust MAM neural responses ranged from a slight diminution of muscle afferent discharge compared to pre-thrust, to a complete cessation of afferent discharge for nearly 3 seconds.56 The purpose of this preliminary study is to begin to characterize the temporal effects of two electromagnetic solenoid-powered MAM devices (Activator Methods Int. Ltd., Phoenix, AZ [Fig. 1A] and Pulstar; Sense Technology Inc., Pittsburgh, PA [Fig. 1B]) on muscle spindle discharge to inform future studies.

Figure 1.

Figure 1

Photographs of the Activator V (A), and Pulstar (B) mechanical-assisted manipulation devices.

Methods

General Surgery

All experiments were reviewed and approved by the Palmer Institutional Animal Care and Use Committee #20120601. Electrophysiological activity in 6 muscle spindle afferent fibers was obtained during MAM delivered to 6 deeply anesthetized male cats weighing between 4.4 and 6.0kg [mean 5.3 (SD 0.6)]. Data collected using these electromagnetic MAM devices were from experimental preparations associated with a separate larger study investigating the relationship between intervertebral fixation and spinal manipulation as delivered by a computer controlled feedback motor.55 The surgical and experimental procedures, including monitoring the preparation’s anesthetic level and physiological status as well as methods of isolating paraspinal muscle spindle afferents have been previously described in detail elsewhere51,52,55,57,58 and thus are only presented here briefly. Anesthesia was induced with isoflurane and maintained with sodium pentobarbital (35mg/kg, iv). Catheters were placed in the common carotid artery and external jugular vein to monitor blood pressure, introduce fluids and anesthesia. The trachea was intubated, and the cat ventilated mechanically. Arterial gases and body temperature were monitored and maintained within the reference range (pH 7.32–7.43; PCO2, 32–37mmHg; PO2, >85mmHg, 38–39°C). Body temperature was continuously monitored and maintained between 38–39°C using a water-heating pad/radiant heat. Additional Nembutal (5 mg/kg) was administered (iv) upon withdrawal reflex to noxious pinching of the toe pad or when mean arterial pressure increased above 100mmHg.

To better isolate trunk muscle afferents, the right sciatic nerve was cut to reduce afferent input from the hindlimb. The lumbar spine was mechanically secured at the L4 spinous and the iliac crests. A midline skin incision was made and an L5 laminectomy was performed to expose the L6 dorsal rootlets while leaving all intervertebral joints intact. The L6 dorsal rootlets were cut close to the spinal cord and thin filaments were teased using forceps until impulse activity from a single trunk muscle spindle afferent was identified (Fig. 2). Action potentials were recorded using a PC-based data acquisition system (Spike 2; Cambridge Electronic Design, Cambridge, UK). Afferents were identified as muscle spindles based on their increased discharge to succinylcholine (100–200mg/kg intra-arterially; Butler Schein, Dublin, OH), decreased discharge to electrically induced muscle contraction, and/or sustained response to a fast vibratory stimulus. At the end of the experiment, animals were euthanized by an intravenous overdose of pentobarbital.

Figure 2.

Figure 2

Example of a paraspinal muscle spindle response to an Activator V mechanically-assisted manipulation (MAM) at magnitude setting of 2. Note the increase in discharge during preload and thrust delivery followed by a period of discharge cessation and subsequent return to resting discharge frequency. Time required for spindle discharge to return to 95% of baseline MIF/MF for a minimum period of 1s was 4.5 and 10.5s respectively.

Mechanically-Assisted Manipulation

Both the Activator V and Pulstar are commercially available hand-held clinical MAM devices. The Activator V has four progressive thrust magnitude settings and requires that the device tip to completely retracted during pre-load (~2.9N) before a single mechanical impulse can delivered at any device setting. When tested against a stiff spinal tissue analog (258.07 N/mm), Activator V delivered mean peak forces of 52, 68, 112, and 155N at settings 1–4 respectively in hand-held operations.18 Device testing on more compliant spinal tissue analog (30.22 N/mm) resulted in mean peak forces of 35, 63, 102N at settings 1–3 respectively.18 The Pulstar device has 7 settings and can be used to deliver either single or multiple high velocity mechanical impulses (22–155N) once the pre-defined preload value of ~15N has been successfully applied.13,14 The three lowest settings on the Pulstar device deliver approximate peak forces of 22, 44, and 67N respectively. In the present study, only single impulses were delivered using the Pulstar device. All MAM thrusts were delivered perpendicularly onto the exposed fascia overlying the cat’s L7 spinous process as previously described.56 The L7 spinous was chosen to receive MAM due to the potential increased risk for repetitive L6 manipulations to tear the L6 afferent fiber off the recording electrode. Typically, three HVLA thrusts were delivered per afferent at each of the three lowest settings of the respective MAM devices (18 thrusts total) with 5 minute intervals between thrusts. Use of MAM devices and device settings (thrust magnitudes) were randomized to minimize any possible ordering effects. At times, not all MAM test protocols were completed before the neural recording was lost. Four afferents received L7 HVLA thrusts from both MAM devices while two afferents received L7 HVLA thrusts from only the Pulstar device.

Data Analysis

Muscle spindle discharge was quantified as mean frequency (MF) and mean instantaneous frequency (MIF). MIF was calculated by taking the reciprocal of the time interval between successive action potentials. Baseline MF/MIF activity measures were obtained during a 2 second period that immediately preceded MAM device contact and/or soft tissue preload as in previous studies5153,55 (Fig. 2). The following three response measures were determined: 1) the time required post-thrust until the 1st action potential, 2) MF and MIF differences between 2s post-MAM thrust and 2s of baseline activity, and 3) the time required for spindle discharge to return to 95% of baseline MF/MIF for a minimum period of 1s following MAM (Fig. 2). The descriptive data presented in Tables 14 are mean responses or time durations from 8 to 18 individual MAM thrusts delivered at a given device setting. Statistical comparisons were made between device settings of a given MAM device using the mean afferent responses to the MAM thrusts delivered at each device setting. For the Pulstar device, nonparametric comparisons of magnitude settings were performed on ranked data to minimize the effect of increased variability coupled with smaller sample size using the Wilcoxon Signed Ranks Test. Statistical comparisons for the Activator V device were not performed due to fewer afferents tested with this device. Statistical significance was set at P < 0.05 and data variance is shown as standard error of the mean (SEM) unless otherwise noted.

Table 1. Neural Response Characteristics Following Activator V MAM.

Shows the time required until the first action potential and the mean differences between mean frequency (MF) and mean instantaneous frequency (MIF) 2s after Activator V mechanical-assisted manipulation (MAM) and 2s baseline measures. All Activator V MAM thrusts resulted in a decrease in spindle discharge relative to baseline activity.

Time (s) to 1st Action Potential After
MAM
Change from Baseline During 2s After
MAM
Force
Setting 3

(n=8)
Setting 1

(n=9)
Setting 2

(n=12)
Force
Setting 3

(n=8)
Setting 1

(n=9)
Setting 2

(n=12)
Mean Time (SEM) .054 (0.01) .465 (0.2) .607 (0.4) Mean MF (SEM) −2.2 (0.6) −6.0 (2.2) −3.9 (1.8)
Mean MIF (SEM) −2.1 (0.5) −6.6 (2.5) −4.0 (1.9)

Table 4. Time Required to Return to 95% of Baseline MF & MIF After Pulstar MAM.

Time required to return to 95% of baseline mean frequency (MF) and mean instantaneous frequency (MIF) discharge for a minimum of 1s following Pulstar mechanical-assisted manipulation (MAM). Different subpopulations of spindle afferents appear to exist according to the time required to return to MF/MIF baseline. The reported values are the percentage of afferents returning to MF/MIF baseline discharge for the respective time period.

Mean Frequency (MF) Mean Instantaneous Frequency (MIF)
Force

Time (s)
22N
(n=18)
44N
(n=18)
67N
(n=15)
22N
(n=18)
44N
(n=18)
67N
(n=15)
0 – 1.99 11% 0% 13% 39% 22% 13%
2 – 3.99 17% 11% 7% 22% 33% 33%
4 – 5.99 28% 11% 0% 28% 17% 20%
6 – 7.99 5% 17% 20% 0% 11% 7%
8 –10 5% 5% 13% 5% 6% 0%
>10 34% 56% 47% 6% 11% 27%

Results

Responses to MAM from 6 muscle spindle afferents with receptive fields located in paraspinal muscles (longissimus or multifidus) were recorded in 6 cats. Mean muscle spindle response characteristics for individual MAM thrust settings are presented in Tables 14. Note that applied forces, pulse widths, device preload settings, etc. are not equivalent between devices thus direct comparisons between MAM devices are inappropriate.

Activator V Device

An example of a raw recording from a single afferent to MAM using the Activator at the 2nd device setting is shown in Figure 2. Progressive increases in Activator V MAM thrust forces typically resulted in longer mean delays until the 1st post-thrust action potential (Table 1). Compared to the 2s of baseline activity, MAM resulted in mean decreases in spindle discharge for both MF and MIF during the 2s post-MAM thrust. Progressive increases in MAM thrust forces did not necessarily result in greater changes in MF/MIF between 2s after MAM and 2s baseline measures. The greatest mean change in MF and MIF occurred at the 2nd device setting on the Activator V (Table 1). Regarding the time required for MF/MIF to return to 95% of baseline following Activator MAM (Table 2), 25–45% of the afferents tested returned to baseline MF within 2s post-MAM and no afferent required longer than 8s to return to baseline MF at device setting 1. However at ActivatorV device settings 2 and 3, over 33% of afferents required >10s thus creating a distinct separation of those afferents requiring shorter (<2s) or longer (>10s) durations to return to baseline MF. Regardless of device setting, the vast majority of afferents (67–89%) tested with the Activator V returned to baseline MIF within 2s and no afferent required a period greater than 8s (Table 2).

Table 2. Time Required to Return to 95% of Baseline MF & MIF After Activator V™ MAM.

Time required to return to 95% of baseline mean frequency (MF) and mean instantaneous frequency (MIF) discharge for a minimum of 1s following Activator V mechanical-assisted manipulation (MAM). Different subpopulations of spindle afferents appear to exist according to the time required to return to MF/MIF baseline. The reported values are the percentage of afferents returning to MF/MIF baseline discharge for the respective time period.

Mean Frequency (MF) Mean Instantaneous Frequency (MIF)
Force

Time (s)
Setting 1
(n=9)
Setting 2
(n=12)
Setting 3
(n=8)
Setting 1
(n=9)
Setting 2
(n=12)
Setting 3
(n=8)
0 – 1.99 45% 33% 25% 89% 67% 75%
2 – 3.99 33% 8% 0% 11% 8% 0%
4 – 5.99 11% 8% 12% 0% 25% 0%
6 – 7.99 11% 0% 25% 0% 0% 25%
8 – 10 0% 8% 0% 0% 0% 0%
>10 0% 43% 38% 0% 0% 0%

Pulstar Device

An example of 3 raw recordings from a single muscle spindle afferent to MAM using the Pulstar device at settings of 22, 44, and 67N are shown in Figure 3. The time required until the first action potential was similar at 44 and 67N. Compared to the 2s of baseline activity, Pulstar MAM resulted in mean decreases in spindle discharge for both MF and MIF during the 2s post-MAM thrust at all thrust magnitudes (Table 3). Regarding the time required for MF/MIF to return to 95% of baseline following MAM (Table 4), it is interesting to note that over 33% of afferents tested required more than 10s to return to baseline MF at all Pulstar device settings tested. The delay in return to baseline MIF with the Pulstar was broadly distributed across post- MAM time intervals at each of the three device settings tested (Table 4). Nonparametric comparisons between outcomes among the different Pulstar device settings yielded significant differences between 22 and 44N settings for the time required to return to 95% of baseline MF and MIF (P < .05). The mean time required to return to baseline MF was 8.4s (1.9) and 14.8s (2.6) for the 22 and 44N setting respectively. The mean time required to return to baseline MIF was 3.4s (0.3) and 5.2s (0.8) for the 22 and 44N Pulstar device settings.

Figure 3.

Figure 3

Three recordings from the same muscle spindle afferent in response to mechanically-assisted manipulation (MAM) using the Pulstar at the 22, 44 and 67N device settings (A–C respectively). Mean discharge frequency was the greatest during the 22N thrust (A). Peak mean discharge frequencies were similar for the 44N (B) and 67N (C) MAM thrust. The 67N thrust exhibited a more pronounced decrease in post-MAM discharge. The secondary peak in mean frequency discharge with the 67N thrust may have been the result of the increased forces and/or recoil contact due to the device being hand-held.

Table 3. Neural Response Characteristics Following Pulstar MAM.

Shows the time required until the first action potential and mean differences between mean frequency (MF) and mean instantaneous frequency (MIF) 2s after Pulstar mechanical-assisted manipulation (MAM) and 2s baseline measures. All Pulstar MAM thrusts resulted in a decrease in spindle discharge relative to baseline activity.

Time (s) to 1st Action Potential After
MAM
Change from Baseline During 2s After
MAM
Force
67N

(n=15)
22N

(n=18)
44N

(n=18)
Force
67N

(n=15)
22N

(n=18)
44N

(n=18)
Mean Time (SEM) .229 (0.9) .289 (0.1) .284 (0.1) Mean MF (SEM) −5.1 (0.6) −4.9 (0.9) −4.3 (1.3)
Mean MIF (SEM) −4.1 (0.5) −4.3 (1.0) −3.4 (1.5)

Discussion

Basic investigations related to neurophysiological changes associated with MAM are important in order to establish underlying mechanisms responsible for spinal manipulation efficacy and to optimize treatment regimens for the 40–60% of chiropractic and/or other manual therapy clinicians in the United States, Canada, Britain, Belgium, New Zealand and Australia who use these mechanical manipulation devices in some capacity of patient care.5964 Despite recent strides being made in determining both the mechanical characteristics and/or physiological effects of MAM,13,15,17,18,25,56,6574 to our knowledge, this study is the first to record muscle spindle response evoked using solenoid powered hand-held clinical MAM device technology and only the second to investigate muscle spindle response using any type of MAM device.

This study confirms findings of a previous report using a spring-loaded MAM device (Activator IV) demonstrating that a range of muscle spindle responses are elicited by MAM.56 The combined tissue preload and extremely short MAM thrust durations elicited high frequency discharge from paraspinal muscle spindle afferents followed by a decrease in post-MAM activity. The progressive increase in applied forces typically increased the time required until the 1st action potential (Tables 1, 3). However, this relationship between applied force and delayed neural response did not necessarily prove to be the case with regard to the amount of time required to return to 95% of baseline MF or MIF. Nonparametric analyses of afferent response to Pulstar thrusts indicated significant differences between 22 and 44N thrust settings with greater time being required to MF/MIF to return to 95% baseline levels for the 44N MAM thrust but not between the 44 and 67N thrust settings. There appeared to be distinct subpopulations of afferent responses with some returning to baseline activity levels relatively rapidly (<4s) while others required much longer periods (>10s) (Tables 2, 4). It is not known whether these differences are due to inherit differences related to muscle spindle intrafusal fibers types such as bag1, bag2 and/or chain fibers (see Reed et al.75 for greater detail) or to other biological factors.

In the present study we provide post-MAM data regarding changes in both MF and MIF (Tables 14), while in the past51,54 we have primarily focused our attention on MIF changes during the thrust phase (time to peak force) of the spinal manipulation. Due to the lack of tissue preload standardization and hand-held vs computer controlled feedback motor clinical delivery methods, we have chosen to focus on the post-thrust MAM muscle spindle response instead of the spindle response elicited during the thrust. Since muscle spindle afferents typically discharge tonically while at rest, we thought providing the time required to return to 95% baseline activity for both MF and MIF might provide a more complete picture of post-thrust MAM response. As clearly illustrated in Fig. 2, MF and MIF recovery do not always occur within close proximity, but generally speaking, these two response measures typically occurred within 0.5–2s of each other. Comparisons for the Pulstar device indicated significant increases for both MF and MIF when comparing time to return to baseline spindle activity following MAM thrusts delivered at the 22 and 44N device settings. We are uncertain as to how this prolonged delay in return to baseline discharge following MAM affects central interneuron, gamma and/or alpha-motoneuron activity and whether or not these delay differences contribute to the physiological mechanisms or clinical efficacy of spinal manipulation. Answers to these questions will require additional basic and clinical investigation using MAM devices.

Limitations

Preload forces and preload durations were not standardized and MAM devices were not rigidly secured or instrumented to record the actual forces delivered. Instead, MAM devices were hand-held as typically used in clinical settings and care was taken to apply the minimum preload necessary to trigger the respective MAM device. While we tested the 3 lowest settings on each clinical device (with peak forces as low as 22N), peak forces were not scaled to feline bodyweight per se. While aspects of a scaling requirement have validity, determining the best scaling parameters is far from clear. Localized thrust forces are quickly dampened by surrounding viscoelastic in vivo tissues and biological cell response does not scale with body weight.18,76 Compared to direct load cell MAM testing, recent evidence using spinal tissue analogs demonstrate that applied MAM peak forces are substantially lower (up to 59%) based on localized viscoelastic tissue compliance combined with additional compliance from the hand/wrist/forearm when devices are hand-held.18 It should be noted that L7 MAM thrust procedures were not intense enough to tear nearby L6 finely teased afferent fibers from the recording electrode and no tissue damage or spinal fractures occurred with multiple MAM thrusts. While future studies should consider scaling of applied MAM peak forces, this study highlights the need to determine the actual forces being transmitted through the spine and surrounding tissues in vivo and suggests that these applied forces are likely substantially lower than those reported in the literature following testing on highly idealized beam structures.18

Conclusions

This study marks the first time that paraspinal muscle spindle response characteristics related to the delivery of extremely short duration (<10ms) solenoid powered MAM thrusts has been reported. Overall, MAM thrusts resulted decreased muscle spindle discharge with a majority of afferents requiring prolonged periods of time (>6s) to return to pre-thrust levels of MF/MIF activity. This neurophysiological effect of MAM far outlasts the 2–7ms stimulus duration, but determination as to how this prolonged delay in return to baseline activity levels impacts spinal or supraspinal mechanosensory processing or clinical outcomes will require additional investigation.

This study found that short duration (<10ms) mechanically-assisted lumbar manipulative thrusts decreases muscle spindle discharge relative to baseline activity,

It required prolonged periods (>6s) for paraspinal muscle spindles to return to their pre-thrust resting discharge activity levels following short duration (<10ms) mechanically-assisted spinal manipulative thrusts.

This study suggests that subpopulations of muscle spindle afferents respond differently to short duration mechanically-assisted spinal manipulative thrusts.

These findings may become important to patient care if future studies show that mechanosensory response is a mechanism that contributes to the clinical efficacy of spinal manipulation.

Acknowledgments

The authors would like to thank Darlene Burke for statistical analyses support. The authors would also like to thank Arlan Fuhr of Activator Methods International and Christian Evans of Sense Technology Inc. for providing the MAM devices used in this study.

FUNDING SOURCES

This work was supported by the NIH National Center for Complementary and Integrative Health (K01AT005935) to WRR and was conducted in a facility with support from the NIH National Center for Research Resources under Research Facilities Improvement Grant Number C06RR15433.

Footnotes

Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Contributorship

Concept development (provided idea for the research) WRR, JGP, MRG

Design (planned the methods to generate the results) WRR,

Supervision (provided oversight, responsible for organization and implementation, writing of the manuscript) WRR

Data collection/processing (responsible for experiments, patient management, organization, or reporting data) WRR, RSS

Analysis/interpretation (responsible for statistical analysis, evaluation, and presentation of the results) WRR, JWL, JGP, MRG, MAL

Literature search (performed the literature search) WRR, MAL

Writing (responsible for writing a substantive part of the manuscript) WRR

Critical review (revised manuscript for intellectual content, this does not relate to spelling and grammar checking) WRR, JWL, RSS, JGP, MRG, MAL

Other (list other specific novel contributions)

CONFLICTS OF INTEREST

No conflicts of interest were reported for this study.

Contributor Information

William R Reed, Palmer Center for Chiropractic Research, Palmer College of Chiropractic, Davenport, IA; USA.

Joel G Pickar, Palmer Center for Chiropractic Research, Palmer College of Chiropractic, Davenport, IA; USA.

Randall S Sozio, Palmer Center for Chiropractic Research, Palmer College of Chiropractic, Davenport, IA; USA.

Michael A.K. Liebschner, Department of Neurosurgery, Baylor College of Medicine; Research Service Line, Michael E. DeBakey VA Medical Center, Houston, TX; USA.

Joshua W. Little, Center for Anatomical Science and Education, Department of Surgery, Saint Louis University School of Medicine, St. Louis, MO; USA.

Maruti R Gudavalli, Palmer Center for Chiropractic Research, Palmer College of Chiropractic, Davenport, IA; USA.

References

  • 1.Freburger JK, Holmes GM, Agans RP, et al. The rising prevalence of chronic low back pain. Arch Intern Med. 2009;169:251–8. doi: 10.1001/archinternmed.2008.543. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Guo HR, Tanaka S, Halperin WE, et al. Back pain prevalence in US industry and estimates of lost workdays. Am J Public Health. 1999;89:1029–35. doi: 10.2105/ajph.89.7.1029. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Rubin DI. Epidemiology and risk factors for spine pain. Neurologic clinics. 2007;25:353–71. doi: 10.1016/j.ncl.2007.01.004. [DOI] [PubMed] [Google Scholar]
  • 4.van Tulder M, Koes B, Bombardier C. Low back pain. Best Pract Res Clin Rheumatol. 2002;16:761–75. doi: 10.1053/berh.2002.0267. [DOI] [PubMed] [Google Scholar]
  • 5.Childs JD, Cleland JA, Elliott JM, et al. Neck pain: Clinical practice guidelines linked to the International Classification of Functioning, Disability, and Health from the Orthopedic Section of the American Physical Therapy Association. J Orthop Sports Phys Ther. 2008;38:A1–a34. doi: 10.2519/jospt.2008.0303. [DOI] [PubMed] [Google Scholar]
  • 6.Pillastrini P, Gardenghi I, Bonetti F, et al. An updated overview of clinical guidelines for chronic low back pain management in primary care. Joint, Bone, Spine. 2012;79:176–85. doi: 10.1016/j.jbspin.2011.03.019. [DOI] [PubMed] [Google Scholar]
  • 7.Bronfort G, Haas M, Evans R, et al. Effectiveness of manual therapies: the UK evidence report. Chiropr Osteopath. 2010;18:3. doi: 10.1186/1746-1340-18-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Chou R, Qaseem A, Snow V, et al. Diagnosis and treatment of low back pain: a joint clinical practice guideline from the American College of Physicians and the American Pain Society. Ann Intern Med. 2007;147:478–91. doi: 10.7326/0003-4819-147-7-200710020-00006. [DOI] [PubMed] [Google Scholar]
  • 9.Chou R, Huffman LH. Nonpharmacologic therapies for acute and chronic low back pain: a review of the evidence for an American Pain Society/American College of Physicians clinical practice guideline. Ann Intern Med. 2007;147:492–504. doi: 10.7326/0003-4819-147-7-200710020-00007. [DOI] [PubMed] [Google Scholar]
  • 10.Chou R, Atlas SJ, Stanos SP, et al. Nonsurgical interventional therapies for low back pain: a review of the evidence for an American Pain Society clinical practice guideline. Spine. 2009;34:1078–93. doi: 10.1097/BRS.0b013e3181a103b1. [DOI] [PubMed] [Google Scholar]
  • 11.Dagenais S, Tricco AC, Haldeman S. Synthesis of recommendations for the assessment and management of low back pain from recent clinical practice guidelines. Spine J. 2010;10:514–29. doi: 10.1016/j.spinee.2010.03.032. [DOI] [PubMed] [Google Scholar]
  • 12.Keller TS, Colloca CJ, Moore RJ, et al. Three-dimensional vertebral motions produced by mechanical force spinal manipulation. J Manipulative Physiol Ther. 2006;29:425–36. doi: 10.1016/j.jmpt.2006.06.012. [DOI] [PubMed] [Google Scholar]
  • 13.Evans JM. Differential compliance measured by the function recording and analysis system in the assessment of vertebral subluxation. J Vertebral Subluxation Res. 1998;2:15–21. [Google Scholar]
  • 14.Leach RA, Parker PL, Veal PS. PulStar differential compliance spinal instrument: a randomized interexaminer and intraexaminer reliability study. J Manipulative Physiol Ther. 2003;26:493–501. doi: 10.1016/S0161-4754(03)00106-4. [DOI] [PubMed] [Google Scholar]
  • 15.Colloca CJ, Keller TS, Black P, et al. Comparison of mechanical force of manually assisted chiropractic adjusting instruments. J Manipulative Physiol Ther. 2005;28:414–22. doi: 10.1016/j.jmpt.2005.06.004. [DOI] [PubMed] [Google Scholar]
  • 16.Herzog W. The biomechanics of spinal manipulation. J Bodyw Mov Ther. 2010;14:280–6. doi: 10.1016/j.jbmt.2010.03.004. [DOI] [PubMed] [Google Scholar]
  • 17.Kawchuk GN, Herzog W. Biomechanical characterization (fingerprinting) of five novel methods of cervical spine manipulation. J Manipulative Physiol Ther. 1993;16:573–7. [PubMed] [Google Scholar]
  • 18.Liebschner MA, Chun K, Kim N, et al. In vitro biomechanical evaluation of single impulse and repetitive mechanical shockwave devices utilized for spinal manipulative therapy. Ann Biomed Eng. 2014;42:2524–36. doi: 10.1007/s10439-014-1115-4. [DOI] [PubMed] [Google Scholar]
  • 19.Herzog W, Conway PJ, Kawchuk GN, et al. Forces exerted during spinal manipulative therapy. Spine. 1993;18:1206–12. doi: 10.1097/00007632-199307000-00014. [DOI] [PubMed] [Google Scholar]
  • 20.Hessell BW, Herzog W, Conway PJ, et al. Experimental measurement of the force exerted during spinal manipulation using the Thompson technique. J Manipulative Physiol Ther. 1990;13:448–53. [PubMed] [Google Scholar]
  • 21.Cambridge ED, Triano JJ, Ross JK, et al. Comparison of force development strategies of spinal manipulation used for thoracic pain. Man Ther. 2012;17:241–5. doi: 10.1016/j.math.2012.02.003. [DOI] [PubMed] [Google Scholar]
  • 22.Forand D, Drover J, Suleman Z, et al. The forces applied by female and male chiropractors during thoracic spinal manipulation. J Manipulative Physiol Ther. 2004;27:49–56. doi: 10.1016/j.jmpt.2003.11.006. [DOI] [PubMed] [Google Scholar]
  • 23.Triano J, Schultz AB. Loads transmitted during lumbosacral spinal manipulative therapy. Spine. 1997;22:1955–64. doi: 10.1097/00007632-199709010-00003. [DOI] [PubMed] [Google Scholar]
  • 24.Triano JJ. Biomechanics of spinal manipulative therapy. Spine J. 2001;1:121–30. doi: 10.1016/s1529-9430(01)00007-9. [DOI] [PubMed] [Google Scholar]
  • 25.Kawchuk GN, Prasad NG, McLeod RC, et al. Variability of force magnitude and force duration in manual and instrument-based manipulation techniques. J Manipulative Physiol Ther. 2006;29:611–8. doi: 10.1016/j.jmpt.2006.08.013. [DOI] [PubMed] [Google Scholar]
  • 26.Nathan M, Keller TS. Measurement and analysis of the in vivo posteroanterior impulse response of the human thoracolumbar spine: a feasibility study. J Manipulative Physiol Ther. 1994;17:431–41. [PubMed] [Google Scholar]
  • 27.Cramer GD, Gregerson DM, Knudsen JT, et al. The effects of side-posture positioning and spinal adjusting on the lumbar Z joints: a randomized controlled trial with sixty-four subjects. Spine. 2002;27:2459–66. doi: 10.1097/00007632-200211150-00008. [DOI] [PubMed] [Google Scholar]
  • 28.Gal J, Herzog W, Kawchuk G, et al. Movements of vertebrae during manipulative thrusts to unembalmed human cadavers. J Manipulative Physiol Ther. 1997;20:30–40. [PubMed] [Google Scholar]
  • 29.Keller TS, Colloca CJ, Gunzburg R. Neuromechanical characterization of in vivo lumbar spinal manipulation. Part I. Vertebral motion. J Manipulative Physiol Ther. 2003;26:567–78. doi: 10.1016/j.jmpt.2003.08.003. [DOI] [PubMed] [Google Scholar]
  • 30.Maigne JY, Guillon F. Highlighting of intervertebral movements and variations of intradiskal pressure during lumbar spine manipulation: a feasibility study. J Manipulative Physiol Ther. 2000;23:531–5. doi: 10.1067/mmt.2000.109679. [DOI] [PubMed] [Google Scholar]
  • 31.Gemmell HA, Jacobson BH. The immediate effect of activator vs. meric adjustment on acute low back pain: a randomized controlled trial. J Manipulative Physiol Ther. 1995;18:453–6. [PubMed] [Google Scholar]
  • 32.Schneider MJ, Brach J, Irrgang JJ, et al. Mechanical vs manual manipulation for low back pain: an observational cohort study. J Manipulative Physiol Ther. 2010;33:193–200. doi: 10.1016/j.jmpt.2010.01.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Shearar KA, Colloca CJ, White HL. A randomized clinical trial of manual versus mechanical force manipulation in the treatment of sacroiliac joint syndrome. J Manipulative Physiol Ther. 2005;28:493–501. doi: 10.1016/j.jmpt.2005.07.006. [DOI] [PubMed] [Google Scholar]
  • 34.Wood TG, Colloca CJ, Matthews R. A pilot randomized clinical trial on the relative effect of instrumental (MFMA) versus manual (HVLA) manipulation in the treatment of cervical spine dysfunction. J Manipulative Physiol Ther. 2001;24:260–71. doi: 10.1067/mmt.2001.114365. [DOI] [PubMed] [Google Scholar]
  • 35.Schneider M, Haas M, Glick R, et al. Comparison of spinal manipulation methods and usual medical care for acute and subacute low back pain: a randomized clinical trial. Spine. 2015;40:209–17. doi: 10.1097/BRS.0000000000000724. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Bialosky JE, Bishop MD, Price DD, et al. The mechanisms of manual therapy in the treatment of musculoskeletal pain: a comprehensive model. Man Ther. 2009;14:531–8. doi: 10.1016/j.math.2008.09.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Clark BC, Goss DA, Jr, Walkowski S, et al. Neurophysiologic effects of spinal manipulation in patients with chronic low back pain. BMC Musculoskelet Disord. 2011;12:170. doi: 10.1186/1471-2474-12-170. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Cramer GD, Ross K, Raju PK, et al. Quantification of cavitation and gapping of lumbar zygapophyseal joints during spinal manipulative therapy. J Manipulative Physiol Ther. 2012;35:614–21. doi: 10.1016/j.jmpt.2012.06.007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Fuhr AW. The Activator Method. 2. St. Louis: Mosby Elsevier; 2009. [Google Scholar]
  • 40.Pickar JG. Neurophysiological effects of spinal manipulation. Spine J. 2002;2:357–71. doi: 10.1016/s1529-9430(02)00400-x. [DOI] [PubMed] [Google Scholar]
  • 41.Korr IM. The Neurobiologic Mechanisms in Manipulative Therapyed. New York: Plenum Press; 1978. [Google Scholar]
  • 42.Dishman JD, Dougherty PE, Burke JR. Evaluation of the effect of postural perturbation on motoneuronal activity following various methods of lumbar spinal manipulation. Spine J. 2005;5:650–9. doi: 10.1016/j.spinee.2005.08.007. [DOI] [PubMed] [Google Scholar]
  • 43.Dishman JD, Bulbulian R. Spinal reflex attenuation associated with spinal manipulation. Spine. 2000;25:2519–24. doi: 10.1097/00007632-200010010-00015. discussion 25. [DOI] [PubMed] [Google Scholar]
  • 44.Bulbulian R, Burke J, Dishman JD. Spinal reflex excitability changes after lumbar spine passive flexion mobilization. J Manipulative Physiol Ther. 2002;25:526–32. doi: 10.1067/mmt.2002.127073. [DOI] [PubMed] [Google Scholar]
  • 45.Suter E, McMorland G, Herzog W. Short-term effects of spinal manipulation on H-reflex amplitude in healthy and symptomatic subjects. J Manipulative Physiol Ther. 2005;28:667–72. doi: 10.1016/j.jmpt.2005.09.017. [DOI] [PubMed] [Google Scholar]
  • 46.Niazi IK, Turker KS, Flavel S, et al. Changes in H-reflex and V-waves following spinal manipulation. Exp Brain Res. 2015;233:1165–73. doi: 10.1007/s00221-014-4193-5. [DOI] [PubMed] [Google Scholar]
  • 47.Dishman JD, Cunningham BM, Burke J. Comparison of tibial nerve H-reflex excitability after cervical and lumbar spine manipulation. J Manipulative Physiol Ther. 2002;25:318–25. doi: 10.1067/mmt.2002.124420. [DOI] [PubMed] [Google Scholar]
  • 48.Dishman JD, Burke J. Spinal reflex excitability changes after cervical and lumbar spinal manipulation: a comparative study. Spine J. 2003;3:204–12. doi: 10.1016/s1529-9430(02)00587-9. [DOI] [PubMed] [Google Scholar]
  • 49.Pickar JG, Kang YM. Paraspinal muscle spindle responses to the duration of a spinal manipulation under force control. J Manipulative Physiol Ther. 2006;29:22–31. doi: 10.1016/j.jmpt.2005.11.014. [DOI] [PubMed] [Google Scholar]
  • 50.Pickar JG, Sung PS, Kang YM, et al. Response of lumbar paraspinal muscles spindles is greater to spinal manipulative loading compared with slower loading under length control. Spine J. 2007;7:583–95. doi: 10.1016/j.spinee.2006.10.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Reed WR, Cao DY, Long CR, et al. Relationship between Biomechanical Characteristics of Spinal Manipulation and Neural Responses in an Animal Model: Effect of Linear Control of Thrust Displacement versus Force, Thrust Amplitude, Thrust Duration, and Thrust Rate. Evid Based Complement Alternat Med. 2013;2013:492039. doi: 10.1155/2013/492039. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Reed WR, Long CR, Pickar JG. Effects of unilateral facet fixation and facetectomy on muscle spindle responsiveness during simulated spinal manipulation in an animal model. J Manipulative Physiol Ther. 2013;36:585–94. doi: 10.1016/j.jmpt.2013.08.007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Reed WR, Long CR, Kawchuk GN, et al. Neural responses to the mechanical parameters of a high-velocity, low-amplitude spinal manipulation: effect of preload parameters. J Manipulative Physiol Ther. 2014;37:68–78. doi: 10.1016/j.jmpt.2013.12.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Reed WR, Long CR, Kawchuk GN, et al. Neural responses to the mechanical characteristics of high velocity, low amplitude spinal manipulation: Effect of specific contact site. Man Ther. 2015;20:797–804. doi: 10.1016/j.math.2015.03.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55.Reed WR, Pickar JG. Paraspinal Muscle Spindle Response to Intervertebral Fixation and Segmental Thrust Level During Spinal Manipulation in an Animal Model. Spine. 2015;40:E752–9. doi: 10.1097/BRS.0000000000000915. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Reed WR, Liebschner MA, Sozio RS, et al. Neural Response During a Mechanically Assisted Spinal Manipulation in an Animal Model: A Pilot Study. J Nov Physiother Phys Rehabil. 2015;2:20–7. doi: 10.17352/2455-5487.000021. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Cao DY, Reed WR, Long CR, et al. Effects of thrust amplitude and duration of high-velocity, low-amplitude spinal manipulation on lumbar muscle spindle responses to vertebral position and movement. J Manipulative Physiol Ther. 2013;36:68–77. doi: 10.1016/j.jmpt.2013.01.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Pickar JG. An in vivo preparation for investigating neural responses to controlled loading of a lumbar vertebra in the anesthetized cat. J Neurosci Methods. 1999;89:87–96. doi: 10.1016/s0165-0270(99)00060-6. [DOI] [PubMed] [Google Scholar]
  • 59.Examiners NBoC. Job Analysis of Chiropractic: a project report, survey analysis and summary of the practice of chiropractic in Canada. Greeley, Colorado, USA: 1993. National Board of Chiropractic Examiners. [Google Scholar]
  • 60.Examiners NBoC. Job Analysis of Chiropractic: a project report, survey analysis, and summary of the practice of chiropractic within the United States. Greeley, Colorado, USA: 1994. National Board of Chiropractic Examiners. [Google Scholar]
  • 61.Examiners NBoC. Job Analysis of Chiropractic: a project report, survey analysis and summary of the practice of chiropractic in the United States. Greeley, Colorado, USA: 2005. National Board of Chiropractic Examiners. [Google Scholar]
  • 62.Ailliet L, Rubinstein SM, de Vet HC. Characteristics of chiropractors and their patients in Belgium. J Manipulative Physiol Ther. 2010;33:618–25. doi: 10.1016/j.jmpt.2010.08.011. [DOI] [PubMed] [Google Scholar]
  • 63.Read DT, Wilson FJ, Gemmell HA. Activator as a therapeutic instrument: Survey of usage and opinions amongst members of the British Chiropractic Association. Clin Chiropr. 2006;9:70–5. [Google Scholar]
  • 64.Gleberzon BJ. Chiropractic name techniques in Canada: A continued look at demographic trends and their impact on issues of jurisprudence. J Can Chiro Assoc. 2002;46:241–56. [Google Scholar]
  • 65.Colloca CJ, Keller TS, Gunzburg R, et al. Neurophysiologic response to intraoperative lumbosacral spinal manipulation. J Manipulative Physiol Ther. 2000;23:447–57. doi: 10.1067/mmt.2000.108822. [DOI] [PubMed] [Google Scholar]
  • 66.Colloca CJ, Keller TS, Gunzburg R. Neuromechanical characterization of in vivo lumbar spinal manipulation. Part II. Neurophysiological response. J Manipulative Physiol Ther. 2003;26:579–91. doi: 10.1016/j.jmpt.2003.08.004. [DOI] [PubMed] [Google Scholar]
  • 67.Colloca CJ, Keller TS. Stiffness and neuromuscular reflex response of the human spine to posteroanterior manipulative thrusts in patients with low back pain. J Manipulative Physiol Ther. 2001;24:489–500. doi: 10.1067/mmt.2001.118209. [DOI] [PubMed] [Google Scholar]
  • 68.Colloca CJ, Keller TS. Electromyographic reflex responses to mechanical force, manually assisted spinal manipulative therapy. Spine. 2001;26:1117–24. doi: 10.1097/00007632-200105150-00005. [DOI] [PubMed] [Google Scholar]
  • 69.Colloca CJ, Keller TS, Gunzburg R. Biomechanical and neurophysiological responses to spinal manipulation in patients with lumbar radiculopathy. J Manipulative Physiol Ther. 2004;27:1–15. doi: 10.1016/j.jmpt.2003.11.021. [DOI] [PubMed] [Google Scholar]
  • 70.Colloca CJ, Keller TS, Harrison DE, et al. Spinal manipulation force and duration affect vertebral movement and neuromuscular responses. Clin Biomechan. 2006;21:254–62. doi: 10.1016/j.clinbiomech.2005.10.006. [DOI] [PubMed] [Google Scholar]
  • 71.Colloca CJ, Keller TS, Moore RJ, et al. Effects of disc degeneration on neurophysiological responses during dorsoventral mechanical excitation of the ovine lumbar spine. J Electromyogr Kinesiol. 2008;18:829–37. doi: 10.1016/j.jelekin.2007.02.017. [DOI] [PubMed] [Google Scholar]
  • 72.Colloca CJ, Keller TS, Moore RJ, et al. Intervertebral disc degeneration reduces vertebral motion responses. Spine. 2007;32:E544–50. doi: 10.1097/BRS.0b013e318145ac39. [DOI] [PubMed] [Google Scholar]
  • 73.Keller TS, Colloca CJ, Fuhr AW. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool. J Manipulative Physiol Ther. 1999;22:75–86. doi: 10.1016/s0161-4754(99)70111-9. [DOI] [PubMed] [Google Scholar]
  • 74.Symons BP, Herzog W, Leonard T, et al. Reflex responses associated with activator treatment. J Manipulative Physiol Ther. 2000;23:155–9. doi: 10.1016/s0161-4754(00)90244-6. [DOI] [PubMed] [Google Scholar]
  • 75.Reed WR, Cao DY, Ge W, et al. Using vertebral movement and intact paraspinal muscles to determine the distribution of intrafusal fiber innervation of muscle spindle afferents in the anesthetized cat. Exp Brain Res. 2013;225:205–15. doi: 10.1007/s00221-012-3362-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 76.Liebschner MA. Biomechanical considerations of animal models used in tissue engineering of bone. Biomaterials. 2004;25:1697–714. doi: 10.1016/s0142-9612(03)00515-5. [DOI] [PubMed] [Google Scholar]

RESOURCES